1. Switch mek Right Factory Default g SW6 SW7 SW8 Link Mode Selection Off PAUS Link Segment LS Swi Pause Disable Pause Enable Lan Lel Lan Factory Default sw2 FDX HDX Right Left Left Link Propagate LP Fiber Full Duplex Fiber Half Duplex Remote Fault Detect Link sw3 AN MAN Left Right Left segment RFD LS UTP Auto Negotiate UTP Manual Remote Fault Detect Link sw4 100 10 Right Righi Len Propagate RFD LP UTP 100Mbps UTP 10Mbps Left Left Right Symmetrical Fault Detect SFD sw5 FDX HDX UTP Full Duplex UTP Half Duplex Right Left Right Asymmetrical Link Propagate Port 1 to Port 2 ALP P1 P2 SW6 Asymmetrical Link Propagate SW7 See Link Mode Selection Left Right Right port 2 to Port 1 ALP P2 P1 SW8 Right Right Right Asymmetrical RFD LP Figure B DIP Switch Bank 1 SW3 SW4 AND SW5 UTP CONTROL DIP switches SW3 SW4 and SW5 control the setting of the UTP port See Figure C below for the UTP Configuration matrix NOTE Refer to the table in Section 3 2 1 3 of the 10 100M2 User Manual for the more detailed information SW3 SW4 SW5 Function The UTP port is set to auto negotiation with the following modes advertised AN on PDA 100F 100H 10F 10H The UTP port is set to auto negotiation with the following modes advertised AN 199 PDA 100H 10F 10H AN 10 FDX The UTP port is set to auto negotiation with the following modes advertised 10F 10H AN 10 H
2. SW3 Reserved Reserved SW4 M SL SL SW4 MASTER SLAVE Master Slave Auto Select Slave Mode Only When the 10 100M2 module is installedin SW5 SW8 Reserved Reserved a chassis with an Network Management Module NMM2 set the DIP switch to the LEFT M SL position factory default The assignment of mastership is automatically negotiated by the installed management modules To designate the 10 100M2 module as the master of the chassis set the DIP switch on the module to the LEFT M SL position and set the other installed management modules DIP switches to the RIGHT SL position to enable Slave Only mode 2 INSTALL MODULE IN CHASSIS AND CONNECT CABLES a Carefully slide the module into an open slot in the chassis Align the module with the installation guides and ensure that the module is firmly seated against the backplane Secure the module by fastening the front panel thumbscrew push in and turn clockwise to tighten to the chassis front Verify the Pwr LED is ON indicating the chassis is powered b When using a 10 100M2 SFP model 8919N 0 insert the SFP Fiber transceiver into the Port 1 SFP receptacle on the 10 100M2 NOTE The release latch of the SFP Fiber transceiver must be in the closed position before insertion Figure D DIP Switch Bank 2 c Connect an appropriate multimode or single mode fiber cable to the fiber port of the installed module It is important to ensure that the t
3. D indicates the Fiber Optics FO Green No Fiber Link Blinking Fiber Data Activity modules is receiving power from Master Slave BP Green Slave Mode Master Mode the chassis 10Mbps not selected or ON Active 10Mbps UTP link 10Mbps UTP 10 Green disconnected Blinking UTP Data Activity The Fiber Optic link LED indicates the fiber optic connection has jobs uP Green 100Mbps not selected been established 400 or disconnected The UTP link LED indicates UTP Full Duplex the module has established FDX a connection across its UTP port Figure F LED Indicators Form 040 8900N 002 C 9 10 ON Active 100Mbps UTP link Blinking UTP Data Activity Green Half Duplex Full Duplex Omnitron Systems Technology 140 Technology Dr 500 Irvine CA 92618 949 250 6510 tel 949 250 6514 fax www omnitron systems com ost Omnitron Systems Technology Inc iConverter 10 100M2 Plug in Module QUICK START GUIDE The iConverter 10 100M2 is a carrier class media converter and a Network Interface Device NID that provides 10BASE T or 100BASE TX 10 100 to 100BASE FX Fiber media conversion with integrated management The 10 100M2 has built in Operation Administration and Maintenance OAM functionality enabling the 10 100M2 to operate as a managed demarcation point at the customer premises and network edge offering Quality of Service capabilities The 10 100M2 module can be managed using NetOut
4. DX Re UTP port is set to auto negotiation with the following modes advertised MAN 100 FDX The UTP port is set to manual negotiation and is forced to 100F MAN 100 HDX The UTP port is set to manual negotiation and is forced to 100H MAN 10 FDX a UTP port is set to manual negotiation and is forced to MAN 10 HDX be UTP port is set to manual negotiation and is forced to Figure C UTP Configuration Matrix SW6 SW7 SW8 LINK MODES These three DIP switches configure the link mode settings It is recommended to have link modes DOWN default during the initial installation After the circuit has been tested and operational configure the module for the desire mode For detailed information on the operation of the different Link Modes download the application note 7Converter Link Modes available on Omnitron s web site DIP SWITCH BANK 2 SW1 SW2 BACKPLANE ENABLE When the DIP switch is in the LEFT DS position factory default the Backplane Port of the 10 100M2 is isolated from the chassis Ethernet Backplane When the Page 2 DIP switch is in the RIGHT EN position Switch Left Factory Default Right the Backplane Port is enabled This wi PEA Lee allows Ethernet Backplane connectivity Backplane Port A Backplane Port A to an adjacent module via the chassis sw2 B DS Disabled B EN Enabled Backplane Link A or B depending on Pane One Backplane Port B the switch setting
5. Once connected press lt ENTER gt to bring up a command line prompt on the attached PC Management Options iConverter Serial Agent Network Management 1 Chassis and Module Management 2 Set Module Name Preferences Management Module Preferences IP and Control Preferences SNMP Preferences Abandon Preference Changes Save Preference Changes Restore Factory Defaults Restart Management Module Other Networking Features Management Module Maintenance 10 Firmware Update 11 Set Date Time IP Address 192 168 1 220 Chassis Number 1 Enter Choice lt H gt elp E lt xx gt it gt Figure E Command Line Interface Menu Options The CLI interface allows for the detailed configuration of the module It is recommended to configure the module with an IP address associated with the attached network Also SNMP traphost address should be configured if the module is managed with an SNMP based Management System See the 10 100M2 User Manual for complete information LED Function 4 VERIFY OPERATION Legend Color OFF State ON Blinking State Once the module has been Power Pwr Green No power Module has power installed and configured per ON Power Available Power Supply G Power Supply not Blinkina N abl steps 1 3 verify the module is status psx hae installed ie ee operational by viewing the LED 5 Network Ports Status indicators iia aah i ee ON Fiber link is active The Power LE
6. look SNMP Management Software Telnet or the Command Line Interface CLI For the complete User Manual on this product access Omnitron s secure download site and request access http www omnitron systems com login php INSTALLATION PROCEDURE 1 Configure DIP Switches 2 Install Module in Chassis and Connect Cables 3 Configure Module via Command Line Interface 4 Verify Operation 1 CONFIGURE DIP SWITCHES DIP SWITCH BANK 1 SW1 UTP FIBER PAUSE ENABLE When this DIP switch is in the Left OFF position Pause is disabled When the DIP switch is in the Right PAUS position Pause is enabled Switch 1 When a port is configured for Auto Negotiation AN Pause operation is determined during the Switch 8 negotiation process between itself and the link Switch 1 partner The port advertises its Pause capability Symmetrical or No Pause based on the Pause Disable Enable DIP switch setting Bank 2 Loa B i i i E 7 Switch 8 When a port is operating in Manual mode MAN its Pause operation mode is based on the Pause Disable Enable DIP switch setting SW2 FIBER FULL HALF DUPLEX Setting this DIP switch to Half Duplex HDX facilitates a connection that supports Half Duplex Setting this DIP switch to Full Duplex FDX facilitates a connection that supports Full Duplex operation LEFT Figure A DIP Switch Locations Page 1
7. ransmit TX is attached to the receive side of the device at the other end and the receive RX is attached to the transmit side Single fiber SF media converter models operate in pairs The TX wavelength must match the RX wavelength at the other end and the RX wavelength must match the TX wavelength at the other end d Connect the UTP port via a Category 5 cable to a 10BASE T or 100BASE TX Ethernet device 3 CONFIGURE MODULE VIA COMMAND LINE INTERFACE To access the Command Line Interface CLI connect the 10 100M2 RS 232 Console Port to the COM port of a computer equipped with terminal emulation software such as HyperTerminal The Console Port DCE is a mini DIN 6 female connector which can be changed to a DB 9 connector with the included adapter The 10 100M2 Console Port is a standard asynchronous serial interface Start HyperTerminal and select the correct COM Port in the HyperTerminal Connect To window Set the serial port to the following Bits Per Second 57 600 Stop Bits 1 Data Bits 8 Parity NONE Hardware Flow Control NONE Page 3