Home
Check Point Software Technologies Smart-1 5
Contents
1. Terminology SmartEvent Terminology 1 O O O 0 Welcome Thank you for choosing Check Points Smart 1 We hope that you will be satisfied with this system and our support services Check Point products are the most up to date and secure solutions available today Check Point also delivers worldwide educational professional and support services through a network of Authorized Training Centers Certified Support Partners and Check Point technical support personnel We make sure that you get the most out of your security investment Check Point is committed to ongoing improvement of its products The new Smart 1 appliance features an improved RAID system For more about the Internet Security Product Suite and other security solutions see the Check Point Web site http www checkpoint com or call Check Point at 1 800 429 4391 For more technical information about Check Point products consult the Check Point Support Center http supportcenter checkpoint com Welcome to the Check Point family We look forward to meeting all of your current and future network application and management security needs Smart 1 Overview Smart 1 appliances deliver Check Point s market leading security management software blades on a dedicated hardware platform specifically designed for mid size and large enterprise security networks Based upon Check Point s software blade architecture Smart 1 appliances deliver a unified management solution for net
2. Keyboard mouse setting Yes Yes Lights Out Management Page 39 Configuring LOM Keyboard and Mouse To modify a user 1 2 3 4 Select an existing user from the list and click Modify The User Modify dialog box appears Modify the fields as required To change the password select Change Password Click Modify User to apply the changes To delete a user 1 2 Select an existing user from the list and click Delete A message appears Click OK Configuring LOM Keyboard and Mouse To use the remote console feature described above specify the operating system that the host machine is running To configure keyboard and mouse settings 1 2 Click the KVM Settings menu option Select the relevant option e Absolute for Windows e Relative for Linux Click Apply Changes Configuring LOM Network The network settings option enables you to change the default IP address and other basic network settings of Lights Out Management To configure the network settings 1 2 Click the LOM Settings menu option and select Network Select Static and enter the following values e IP address the IP address of the LOM e Subnet mask the subnet mask of the LOM s local network e Gateway IP address the Default Gateway IP address e Remote Console and HTTPS port port number on which the devicea s Remote Console server and HTTPS server are listening Setting the Date and Time This option enables y
3. Safe Drinking Water and Toxic Enforcement Act of 1986 California Health amp Safety Code s 25249 5 et seq Proposition 65 that is known to the State to cause cancer or reproductive toxicity see http Avww calepa ca gov WARNING Handling the cord on this product will expose you to lead a chemical known to the State of California to cause cancer and birth defects or other reproductive harm Wash hands after handling Health and Safety Information Page 4 Welcome Federal Communications Commission FCC Statement Note This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Information to user The user s manual or instruction manual for an intentional or unintentional radiator shall caution the user that changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operat
4. a Rack These instructions show how to install Smart 1 25 in a standard 19 inch rack Safety Instructions Before installing your appliance in a rack cabinet review the following guidelines A Make sure that the room air temperature is below 35 C 95 F Do not block any air vents Normally 15 cm 6 in of air space in the rear and 5 cm 2 in in the front provides proper airflow Install the appliances in the cabinet starting at the bottom and going up Install the heaviest appliance at the bottom of the rack cabinet Do not extend more than one device out of the rack cabinet at the same time Connect the server to a properly grounded outlet Do not overload the power outlet when installing multiple devices in the rack cabinet Mounting Smart 1 25 ina Rack Page 11 Determining Space and Weight Requirements Determining Space and Weight Requirements Allow sufficient vertical space in the rack for the appliance Model Height Weight Kg Smart 1 25 1U 1 75 inch 44 5 mm 13 5 The distance from the center of any hole to the center of the third hole above it is equivalent to 1U The mounting holes in a standard 19 inch 482 6 mm server rack rail are arranged as follows 0 625 Threaded holes Vice or 10 32 A A A Em S 0 625 1 254 1 1U 1 75 0 625 t Y A 0 5 ia Y 2U 3 5 E T A ar y Or 0 625 12 5 E 3U 5 25 0 625 f Y When installing applianc
5. security policy e Management High Availability HA Refers to a configuration in which a primary Security Management server has one or more backup secondary Security Management servers which are ready to take over in case of failure of the primary Security Management server SmartEvent Terminology e SmartEvent and Reporter Suite Includes SmartEvent and SmartReporter e SmartEvent A system that reads logs and generates events based on an Event Policy An IPS event only version is also available Based on the configuration SmartEvent contains these components SmartEvent Client or IPS Event Analysis Client A GUI that displays events or IPS events in many graphical list and map forms and provides user control of the policy SmartEvent Server or IPS Event Analysis Server Holds the event or IPS event database event queries object values and policy definition SmartEvent Correlation Unit An engine which reads logs and creates events e SmartReporter A system that reads logs and generates statistical and data reports SmartReporter contains these components SmartReporter Client A GUI to generate define and display reports SmartReporter Server Contains reports report definitions and report schedules Log Consolidator Reads logs consolidates them according to the consolidation policy and adds them to the SmartReporter database Introduction Page 10 Safety Instructions Mounting Smart 1 25 in
6. Aor Y Select a menu option gt Go back to a previous menu lt To select menu options Menu Sub menu Purpose Network Set MGMT IP Set the management interface IP address Smart 1 Hardware Page 28 Smart 1 5 Menu Sub menu Purpose Set Net mask Set the management interface network mask Set Default GW Set the management interface default gateway System Reboot Reboot the appliance To enter an IP address Action Press Move to the next digit gt Move back to the previous lt digit Approve the change when cursor is located on the last digit Cancel the IP change lt when cursor is located on the first digit Change current digit Aor Y Smart 1 Hardware Page 29 Smart 1 25 Smart 1 25 This section describes the features and components located on the Smart 1 25 appliance Front Panel Item Description 1 Management configuration port 2 Ethernet connection ports Lani Lan2 3 Console RJ 45 port to connect to a computer using a terminal emulation application 4 LCD display screen 5 Lights Out Management LOM port 6 USB ports 7 Hard disk drives LCD Display Screen Smart 1 appliances have an LCD screen that lets you do basic management operations You configure the management IP address net mask and default gateway using the LCD screen You can also reboot and turn off the appliance from the LCD screen Smart 1 Hardware Page 30 Smart 1 25 ltem 10 11 Description On
7. Off indicator LED Network Access LED Disk Access LED LCD Display lt Not currently used A Navigate within a menu Not currently used gt Not currently used Enter Select a menu option or go to the main menu Y Navigate within a menu Esc Go back to the previous menu To use the menus Action Press Enter the main menu Enter Navigate within the menu Aor Select a menu option Enter Go back to a previous menu Esc To select menu options Menu Network System Sub menu Purpose Set MGMT IP Set the management interface IP address Set Net mask Set the management interface network mask Set Default GW Set the management interface default gateway Reboot Reboot the appliance To enter an IP Address Action Press Move to the next digit Enter Move back to the previous Esc digit Smart 1 Hardware Page 31 Customer Replaceable Parts Action Press Confirm the change Enter when the cursor is located on the last digit Cancel the IP change Esc when the cursor is located on the first digit Change current digit Aor Hard Disk drives The Smart 1 25 appliance contains two 3 1 2 hot swappable hard disk drives RAID 1 This lets you do RAID 1 mirroring across the drives using a dedicated LSI Logic RAID controller Customer Replaceable Parts The Smart 1 25 appliance contains these customer replaceable parts e Two power supplies e Two hard disk drives The Check Point warranty and sup
8. Smart 1 5 amp Smart 1 25 Getting Started Guide Models S 10 S 21 8 December 2011 softwareblades Check Point m SOFTWARE TECHNOLOGIES LTO We Secure the Internet 704548 2011 Check Point Software Technologies Ltd All rights reserved This product and related documentation are protected by copyright and distributed under licensing restricting their use copying distribution and decompilation No part of this product or related documentation may be reproduced in any form or by any means without prior written authorization of Check Point While every precaution has been taken in the preparation of this book Check Point assumes no responsibility for errors or omissions This publication and features described herein are subject to change without notice RESTRICTED RIGHTS LEGEND Use duplication or disclosure by the government is subject to restrictions as set forth in subparagraph c 1 ii of the Rights in Technical Data and Computer Software clause at DFARS 252 227 7013 and FAR 52 227 19 TRADEMARKS Refer to the Copyright page http www checkpoint com copyright html for a list of our trademarks Refer to the Third Party copyright notices http Awww checkpoint com Srd_party_copyright html for a list of relevant copyrights and third party licenses Important Information Latest Software We recommend that you install the most recent software release to stay up to date with the latest functional imp
9. Software Blade SmartEvent and Reporter Suite contains SmartReporter Server SmartEvent Server and SmartEvent Correlation Unit Security Management If you choose to install a Security Management server in the Security Management page Security Management Please select one of the following options Primary Security Management O Secondary Security Management Log Server e Primary Security Management is the Security Management server that will normally be active To set up a Security Management server in a non Management HA deployment choose this option In a Management HA deployment if the Primary Security Management server fails the Secondary Security Management server takes over e Secondary Security Management is the Security Management server that takes over if the Primary Security Management server fails This option applies only in a Management HA deployment e Log Server is the repository for log entries generated on gateways Check Point gateways send their log entries to the Log Server SmartEvent and SmartReporter Suite Installation Type Configure the SmartEvent and Reporter Suite applications to run on the server SmartEvent and SmartReporter Suite Installation Type Please select type SmartReporter Server SmartEvent Server SmartEvent Correlation Unit SmartEvent A system that reads logs and generates events based on an Event Policy An IPS event only version is also availa
10. UP arrow 4 Confirm the reset by pressing the UP arrow Pressing any other key causes the Action Canceled message to appear At this point pressing any key returns you to the boot menu Restoring Factory Defaults Page 35 Restoring Using the LCD Panel 5 Once you have confirmed the reset wait for the appliance to restore the factory image While the appliance is restored to the default image a Reverting image don t turn off message displays continuously When the appliance has been restored to its default factory configuration the appliance reboots and the Initializing message appears Restoring Factory Defaults Page 36 Chapter 6 Lights Out Management This chapter discusses the Lights Out Management LOM integrated card that is supplied with the Smart 1 25 appliance and basic configuration options In This Chapter Introduction 38 Initial Login 38 Basic Configuration Options 38 Remotely Controlling the Appliance 38 Remotely Controlling the Power of the Appliance 39 Managing LOM Card Users 39 Configuring LOM Keyboard and Mouse 40 Configuring LOM Network 40 Setting the Date and Time 40 Defining a LOM Login Message 40 Page 37 Introduction Introduction The Check Point Lights Out Management LOM is an optional card that you can use with Check Point appliances You can remotely control Check Point appliances using a dedicated management channel Lights Out Management also works when the appliance is turne
11. ave Disk None DR at Row s O01 i i ECC Function Disabled l PCI device listing Bus No Device No Func No Yendor Device Class Device Class IRQ 0 0 1 8086 3584 0880 Base Sys Peripherals NA 0 0 3 8086 3585 0880 Base Sys Peripherals NA 0 2 0 8086 3582 0300 Display Cntrlr 12 0 29 0 8086 24C2 C03 USB 1 0 1 1 UHCI Cntrir 12 0 29 7 8086 24CD C83 USB 2 0 EHCI Cntrlr 7 0 31 1 8086 24CB 0101 IDE Cntrlr 14 1 4 0 8086 1076 0200 Network Cntrir 12 1 5 0 8086 1076 0200 Network Cntrir 10 1 6 0 8086 1076 0200 Network Cntrir 11 1 7 0 8086 1076 0208 Network Cntrir 5 ACPI Controller 9 Press any key to see the boot menu Booting in 4 seconds Connected 0 08 11 Auto detect 9600 8 N 1 PS NUM Capture Print echo 7 6 When this text appears there are approximately four seconds to press any key in order to bring up the boot grub menu Once the boot grub menu is displayed there will be approximately ten seconds to press any key or the machine will continue booting up 7 Scroll down the grub menu to highlight Reset to factory defaults Select the relevant default image version 8 Press Enter Restoring Using the LCD Panel To restore the Smart 1 appliance to its default factory configuration using the LCD Panel keys 1 Reboot or power on the appliance 2 When the countdown begins press any of the arrow keys The Boot menu appears 3 Using the arrow buttons scroll to the relevant image version and then press the
12. ble SmartReporter is a system that reads logs and generates statistical and data reports Choose one or more of these server components e SmartReporter Server Contains reports report definitions and report schedules e SmartEvent Server Holds the event or IPS event database event queries object values and policy definition e SmartEvent Correlation Unit An engine which reads logs and creates events For IPS Event Analysis select both SmartEvent Server and SmartEvent Correlation Unit Web SSH and GUI Clients Configuration Define the clients that are allowed to connect to Smart 1 appliance using a Web browser SSH client or SmartConsole applications Configuring Smart 1 Page 21 Installing the SmartConsole GUI Clients You can define a Host according to Hostname or IP address Enter Any to manage Smart 1 from anywhere Q Note It is not recommended to use the Any value for security reasons Additional options are available via the WebUI menu after you complete the First Time Configuration Wizard Secure internal Communication In the Secure Internal Communication page enter a SIC Activation Key and remember it as you will enter it again when configuring the object via SmartDashboard Download SmartConsole Applications Configuring a security policy requires you to install the SmartConsole applications In the Download SmartConsole Applications window you can download SmartConsole and install it on Windows mac
13. d screws A powered screwdriver is useful e Pliers Recommended but not essential Preparing the Appliance Prepare the Smart 1 appliance for mounting in the rack You don t need to do this in the server room Attaching the Appliance Rails to the Appliance 1 Separate the appliance rail from the slide Push a release catch and slide the rail away from the slide until they separate 2 Identify the front end The front end is straight not grooved A serial number is engraved near the front end 3 Position the appliance rail on one side of the appliance so that four holes are visible Mounting Smart 1 25 in a Rack Page 14 Attaching the Mounting Brackets to the Slide 4 5 Attach the appliance rail to the appliance using three screws One screw at each end and one screw in one of the two middle holes a D Repeat to attach an appliance rail to the other side of the appliance Attaching the Appliance Ear Brackets Optional The appliance ear brackets are optional Use them as a Handle to make it easier to grab the front of appliance and slide it in and out Buffer that prevents to appliance jamming in the rack in the closed position You can also use the appliance ear brackets to prevent the appliance from sliding in and out of the rack by attaching the bracket ears to the rack vertical rail To connect the two appliance ear brackets to the front of the appliance 1 2 Attach the appliance ea
14. d off or not responding Initial Login 1 Open a web browser and enter the default IP address of the LOM card 192 168 0 100 The login window appears 2 Login with the default User name admin and password admin all lower case SA Note Following 30 minutes of inactivity you are automatically be logged out EI Check Point Unit 192 168 0 100 User name admin fr Home Console Logout Appliance Controt e KVM Console Power Controt Somn 4 LOM User Management r Last Console Capture 2 LOM KVM Settings LOM Settings 4 Maintenance Basic Configuration Options The options in the main menu on Lights Out Management home page let you configure these settings e Remotely control the appliance e Remotely control the power of the appliance e Manage Lights Out Management users e Configure Lights Out Management keyboard and mouse settings e Configure Lights Out Management network settings e Set date and time e Define a Lights Out Management login message Remotely Controlling the Appliance The Appliance Control menu option enables you to access the appliance via a web interface Java application Prior to using this option ensure that you have Java Runtime installed on the host machine To run the remote console 1 Click the Appliance Control menu option Lights Out Management Page 38 Remotely Controlling the Power of the Appliance 2 Select KVM Console and then Open Console A ne
15. detect events To learn how to manage and fine tune the system using the SmartEvent Intro Client see the SmartEvent Administration Guide for your software version on the Check Point Support Center http supportcenter checkpoint com Creating a Consolidation Session for SmartReporter The Consolidation session reads logs from the log server and adds them to the SmartReporter database e If there is a single log server in the environment the Consolidation session is automatically created e f there is more than one log server you must create the Consolidation session for each log server To create a Consolidation session 1 Inthe Selection Bar view select Management gt Consolidation 2 Select the Sessions tab 3 Click Create New to create a new session The New Consolidation Session window appears 4 Select the log server from which logs will be collected and will be used to generate reports 5 Click Next The New Consolidation Session window appears 6 Choose whether to use the default source logs and database tables or select custom source logs and database tables for consolidation If you selected Select default log files and database click Finish to complete the process The source of the reports will be preselected logs The report data will be stored in the default database table named CONNECTIONS The preselected logs are the sequence of log files that are generated by Check Point products The preselected logs sessio
16. e circuitry on the system board can continue operating even though the power is switched off e Under no circumstances should the lithium battery cell used to power the real time clock be allowed to short The battery cell may heat up under these conditions and present a burn hazard A Warning DANGER OF EXPLOSION IF BATTERY IS INCORRECTLY REPLACED REPLACE ONLY WITH SAME OR EQUIVALENT TYPE RECOMMENDED BY THE MANUFACTURER DISCARD USED BATTERIES ACCORDING TO THE MANUFACTURER S INSTRUCTIONS e Disconnect the system board power supply from its power source before you connect or disconnect cables or install or remove any system board components Failure to do this can result in personnel injury or equipment damage e Avoid short circuiting the lithium battery this can cause it to superheat and cause burns if touched e Do not operate the processor without a thermal solution Damage to the processor can occur in seconds For California Perchlorate Material special handling may apply See http www dtsc ca gov hazardouswaste perchlorate The foregoing notice is provided in accordance with California Code of Regulations Title 22 Division 4 5 Chapter 33 Best Management Practices for Perchlorate Materials This product part or both may include a lithium manganese dioxide battery which contains a perchlorate substance Proposition 65 Chemical Chemicals identified by the State of California pursuant to the requirements of the California
17. e equipment by handing it over to a designated collection point for the recycling of waste electrical and electronic equipment The separate collection and recycling of your waste equipment at the time of disposal will help to conserve natural resources and ensure that it is recycled in a manner that protects human health and the environment For more information about where you can drop off your waste equipment for recycling please contact your local city office or your household waste disposal service Health and Safety Information Page 5 Contents important atone OM esac es eee eek cin aed eed eed ee ete 3 Health and Safety Information cccccceeseeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeaeeeeeeeeeeeeeeesnneees 4 Mr UCU ODN aar cts ec a raar a ara baka cd aces ghee etal E aeaea aap aae Kaana aes 8 NVGICOING 2 25 a a a he ON R 8 Smart T Ovevie W serie aaea raa ra eeue aa Aa ATE EKRAN a AENEAN E E ETENE 8 Security Management Software Blades nnnsneesseesnnrnnrreseeernrrrnersserrrrrrrn 8 SManEVEn A areo aa aA aE EEE O R E 9 This document Provide 2 5 ces icici cashcvet idzc helicases idexteel canyevaditenteel eaneeveaadeatiel scenes 9 Shipping Carton Contents rein shc cant tecadties ladpeetaeitucstda ede ened abiaeeeeaenaetets 9 TPTIMIOLO GY AEE cae teen oe critica OA reel Ear eee ately ease ea teas 9 SmartEvent Terminology xii et a tcc ea erste he ta rt GO ai coat tem cate 10 Mounting Smart 1 25 in a RACK cceeeeeeeeeeeeeeeeeeeee
18. e the equipment In cases where the manual is provided only in a form other than paper such as on a computer disk or over the Internet the information required by this section may be included in the manual in that alternative form provided the user can reasonably be expected to have the capability to access information in that form Canadian Department Compliance Statement This Class A digital apparatus complies with Canadian ICES 003 Cet appareil num rique de la classe A est conforme a la norme NMB 003 du Canada Japan Class A Compliance Statement SE eee an ae ee ee I CORB FIAAMBRRAARTT CORB CRERACERT SCRRMHEESFRCTFCEVSHVET COMBS UEREY ANS MRMERBFSSIBRENSCOEVSHVSTF VCCI A European Union EU Electromagnetic Compatibility Directive This product is herewith confirmed to comply with the requirements set out in the Council Directive on the Approximation of the Laws of the Member States relating to Electromagnetic Compatibility Directive 2004 1 08 EC This product is in conformity with Low Voltage Directive 2006 95 EC and complies with the requirements in the Council Directive 2006 95 EC relating to electrical equipment designed for use within certain voltage limits and the Amendment Directive 93 68 EEC Product Disposal This symbol on the product or on its packaging indicates that this product must not be disposed of with your other household waste Instead it is your responsibility to dispose of your wast
19. ed configuration can be done using the sysconfig menu which can only be accessed using the command line interface Q5 Note The sysconfig menu is only available after running the First Time Configuration Wizard in the WebUl Command line access can be obtained by console connection or through SSH Connecting to the Smart 1 CLI You can connect to the command line interface of the Smart 1 appliance using e The provided serial console cable DTE to DTE and terminal emulation software such as HyperTerminal from Windows or Minicom from Unix Linux systems Connection parameters for Smart 1 appliances are 9600bps no parity 1 stop bit 8N1 e An SSH connection to the management interface if SSHD is configured Configuring Smart 1 Page 23 Chapter 3 Configuring SmartEvent This section explains how to get up and running with SmartEvent In This Chapter Preparing SmartEvent on Security Management Server 24 Configuring the SmartEvent Clients 24 Preparing SmartEvent on Security Management Server To configure SmartEvert first establish connectivity between the components 1 Launch SmartDashboard 2 In SmartDashboard create a new host for each computer that contains a component of SmartEvent a Select Manage gt Network Object gt New gt Check Point gt Host b Inthe General Properties window click Communication and enter the activation key Note If the Security Management Server and SmartEvent are insta
20. eeeeeeeaeeeseeeeeeeeeeeeeaeeeeeneeeeeeeeees 11 Safety INSINUCTIONS scscrecticacs aaa e nese a ae aE ERES OaE 11 Determining Space and Weight Requirement scceeeeeeeeeeeeeeeeeeeeeneeeeeeees 12 Rack Mounting Hardware and Required Tools ceeeeeeeeeeeeeeeeeeeeeeeeeeneeeeeeees 13 Preparing the Appliance cceccccceceeeeeeeeeeeeeaeeeeeeeeeeeeeeeaaaaaeeeeeeeeeenessaaaeeeeeees 14 Attaching the Appliance Rails to the Appliance cc ceeeeeeeeeeeeeeeenteeeeeeees 14 Attaching the Appliance Ear Brackets Optional ccceeeeeeeeeeeeseeeeeeees 15 Attaching the Mounting Brackets to the Slid ccceeeeeeeeeeeeeeeeeteeeeeeeeeeeeees 15 Attaching the Slide and Mounting Bracket Assembly to the Rack 000 16 Installing Smart 1 25 in the RACK 0 ceeeeeeeee eter eee eeeenee este tere teeeenaaeeeeeeeeeeneee 17 Configuring Smartt siisii aura aeania iaa raba ani eccnesebncte deed etneaeeetedecdtes 18 Connecting the Power Cables and Power ON ssssssssssserrrrssserrsrrrrnrrsssrrrrerrn 18 Using the First Time Configuration Wizard cccccceeeeeeeeeeceeeeeeeeeeeeeeseenneeeeeeeees 18 Starting the First Time Configuration Wizard c ceeeeeeeeeeeeeeteeeeeeeeeeeeeees 19 Welmer e R nearer A 19 Appliance Date and Time Setup 00 cece eeeeceeeee etter ee eeeeeeaaeeeeeeeeeeteenseaeeeeeeees 19 Network Connections lt r cases cache tat rt coereats E ied 20 Ro t
21. eeeeeteeesnaeees 25 Defining Correlation Units and Log Servers for SmartEvent ceee 25 Creating a Consolidation Session for SmartReporter cceeeeeeeeeeeee 25 Simiatt 1lardware 2 ssl A ee es seine tac de ec cute T 27 SNe 1 Cad i E EE E Be RAE ATP EAE AP OER A EEE ORE a eee OER 28 Front Panel fs aoa a ce eS se hice accra ae ace actitap ete ad Sacer ee a eee ree 28 LCD Display SGrOen acvssccectececGaccteeresevarocbadevansesneaieiine denieneveiecuerttaeueaanieuiedieee 28 SIM AN Zo tesnica ceased hc a a ralta carte ata ata nate a eaa e ste a a a treed 30 Front Panel ccc aetateactet tah er ean enh en ee nee Ye etal 30 LGD Display Scre n iirin eee feck Seed eens e aa D eset cate E es 30 Hard DISK Arves ieena tendvetetoesdnonctadeate a E A A E A a EE 32 Customer Replaceable Parts iizcs iccccieicseeesectteenereeeueiectncsenenesnreiehitiniereeie eae 32 ANEL SUD SIARRA EEE TE As E E E ia ee 32 Hard DISK Drives zer a aE E A L EE EE a aE 33 Removing a Hard Disk Drive ss sexes cote tatneci ca ur apeetie lune Giecaycpaeateeetia ar gemteh ned els 33 Installing a Hard Disk DIWey cas aeetn hwnd apatlitioaneeind adele 33 Restoring Factory Defaults cccccccsssseeeeeeeeeeeeeeeeeeseeeeeeeeeeeeesenseeeneeeeeeeeeeeenees 34 Restoring Factory Defaults using the WebUl cee eeeeeeeeeeeeeeeeeeeeetneeeeeeees 34 Restoring Factory Defaults using the Console sseeesseseseesseeeessseeeeees 34 Rest
22. epeat for the other side of the rack Attach the slide and mounting bracket assembly to the other side of the rack Mounting Smart 1 25 ina Rack Page 16 Installing Smart 1 25 in the Rack damn Smart 1 25 in the Rack Extend the slide fully Carefully line up the appliance with the rail and push it about half way in You will hear a click To slide the appliance fully into the rack press the slide latch on the left then on the right Take care not to trap a finger 4 Slide the appliance into the rack o o o o e o Mounting Smart 1 25 in a Rack Page 17 Chapter 2 Configuring Smart 1 The basic workflow for configuring Smart 1 is 1 Connect the cables and power on 2 Perform the initial configuration using the First Time Configuration Wizard 3 Install the SmartConsole GUI clients In This Chapter Connecting the Power Cables and Power On 18 Using the First Time Configuration Wizard 18 Installing the SmartConsole GUI Clients 22 Completing the Configuration 22 Advanced Configuration 23 Connecting the Power Cables and Power On 1 Connect the power cable s 2 Turn on the Power button to start the appliance S Note When a power supply fails or is not connected to the outlet an alarm sounds continuously If you hear the alarm check that all power supplies are connected to the outlets If needed replace the faulty power supply immediately and connec
23. ert one of the screws through the round hole closest to the back of slide then through the slot in the bracket d Place a threaded washer on the screw and tighten normally e Insert one more screw through the fourth oval hole in the slide furthest from the back then through the slot in the bracket f Place a threaded washer on the screw and tighten normally Close the slide so it is fully retracted You now have a slide and mounting bracket assembly ready to attach to the rack Repeat for the second slide Attach one mounting bracket loosely to the front of the slide and another normally to the back Attaching the Slide and Mounting Bracket Assembly to the Rack Now attach the slide and mounting bracket assembly to the rack 1 2 NO oP amp While standing in the front of the rack place a slide and bracket assembly in position in one side of the rack Attach the mounting bracket to the rack vertical rail at the front using two screws and two washers Place a washer between screw and the rack Extend the slide so that it reaches the vertical rail at the back of the rack Attach the mounting bracket to the rack vertical rail at the back using two screws and washers Go the front of the rack Tighten the screws that attach the slide to the front mounting bracket These screws were earlier left intentionally loose You may need to hold the threaded washer with a pair of pliers while you tighten the screw R
24. es start measuring from the center of the two holes with closer spacing Otherwise the screw holes on the appliance may not match those on the rack Mounting Smart 1 25 in a Rack Page 12 Rack Mounting Hardware and Required Tools Rack Mounting Hardware and Required Tools Description Appliance rail Screw short RoHS 6 32 L5 Ni Slide Mounting bracket Screw long RoHS NUT Flange M4 Coating Ni Threaded washer RoHS 14 0 L8 Ni Appliance ear bracket Use Attaches to the Smart 1 25 appliance Out of the box it comes combined with the slide Both appliance rails are identical Attaches the appliance rail to the appliance Allows the Smart 1 appliance to slide in and out of the rack for access Out of the box it comes combined with the appliance rail Both slides are identical Mounts the slide to the rack vertical rails All mounting brackets are identical Attaches slide to mounting brackets Attaches slide to mounting brackets Attaches to the Smart 1 25 front panel Both bracket ears are identical Mounting Smart 1 25 ina Rack Page 13 Preparing the Appliance Item Description Qty Use Screw 6 Attaches the bracket ears to the appliance Screw 8 Attaches mounting brackets to the rack vertical rails Washer 8 Attaches the mounting brackets to the rack vertical rails Rack Mounting Tools e Philips screwdriver A magnetic head is recommended to hold screws in place and retrieve droppe
25. ge 24 Configuring the SmartEvent Clients Defining the Internal Network for SmartEvent To help SmartEvent Intro determine whether events originated internally or externally the Internal Network must be defined Certain network objects are copied from the management server to the SmartEvent Intro server during the initial synchronization and updated afterwards periodically Define the Internal Network from these objects Note If running IPS Event Analysis in a Security Management Server environment the internal network will be defined automatically from firewall topology information You can customize the internal network definition To define the Internal Network 1 Start the SmartEvent Intro Client 2 From the Policy view select General Settings gt Initial Settings gt Internal Network 3 Add objects hosts networks groups IP ranges that define your environment s internal network Defining Correlation Units and Log Servers for SmartEvent 1 From the Policy view of the SmartEvent Intro client select General Settings gt Initial Settings gt Correlation Units Select Add Click the button of the Correlation Unit field In the Select Objects window select a Correlation Unit Click OK Click Add and select the Log Servers available as data sources to the Correlation Unit Select Save From the Actions menu select Install Events policy ONAOARWD At this point SmartEvent Intro will begin to read logs and
26. hines For a detailed list of supported Windows operating systems for SmartConsole refer to the release notes of your Check Point version in the Check Point Support Center http supportcenter checkpoint com Summary The Summary page appears Click Finish to complete the First Time Configuration Wizard The Appliance automatically restarts This may take several minutes Note It is recommended to backup the system configuration for system recovery purposes The backup menu can be accessed via the WebUI interface under the Appliance menu Installing the SmartConsole GUI Clients 1 The WebUI menu can be accessed by navigating to https lt appliance_ip_address gt 4434 2 Login using the administrator username and password configured in step 4 of the Advanced Initial Configuration step 3 Download the SmartConsole Installation package Product Configuration gt Download SmartConsole gt Download You have now completed the Smart 1 configuration To start working with your Smart 1 appliance as a Security Management Server refer to the Security Management Server Administration Guide for your software version in the Check Point Support Center http supportcenter checkpoint com Completing the Configuration After you have finished the basic configuration of Smart 1 you can configure SmartEvent Configuring SmartEvent on page 24 Configuring Smart 1 Page 22 Advanced Configuration Advanced Configuration Advanc
27. ing ALS sets tk seins ta Sere tacts cc sa scene da eet pn dae Mee ea dae area ates 20 DNS and Domain Settings lt cicei ike cee ee pede wena au ahe tae 20 Security Management Installation Type cceeeeeeeeeeeeeeeeeeeeeeeeneeeeeeeeeeteees 20 Security MaAnAGSMeM is lt cca Mazes acct ce adie reac tuavtagune Bcaden de vendawese cetagerazeuavees 21 SmartEvent and SmartReporter Suite Installation Type ceeeeeeeeeee 21 Web SSH and GUI Clients Configuration ccccecceeceeeeeeeeeeeeeeeeesenteeeeeeees 21 Secure Internal Communication sc scnnteteitra Hic endueecnhincdinaeeteeepeddaeanadeoeeaeadias 22 Download SmartConsole Applications cccceeeeeeeeeeeeeeeeeneeeeeeeeeeeeeeeenaaees 22 S MMAY soke seek eeaceae alee cert eas a e ak a a aa e AA RA 22 Installing the SmartConsole GUI Clients ssenssnnneneeeseeeennernnrrsseeennrrnnnrsserrnnne 22 Completing the Configuration cccccceeeeeeeeeeeeeeeeeeeeeeeeetenesaaaeeeeeeeeeeeeeenaaaaes 22 Advanced CONNGURANON zr e a a E AE 23 Connecting to the Smart 1 Gc geet eet enensaetivnetuenc Tene ivhetuaeetemeereetiaet 23 Configuring SInMartE Vent xcs ccs cect ceke eect eee ete aee erie cea eect es 24 Preparing SmartEvent on Security Management Servel ccccceeeeeeeteereeeeees 24 Configuring the SmartEvent Clients ccc eeeeceeee teeter eeeeeeneeeeeeeeeeeteeeeaaees 24 Defining the Internal Network for SmartEvent ceecceeeseeeeee
28. k Login Ss Note The features configured in the wizard are accessible after completing the wizard via the WebUI menu The WebUI menu can be accessed by navigating to https lt appliance ip address gt 4434 5 Change the administrator password as prompted The default password is provided to allow to you access to Smart 1 For security purposes you must change it to a more secure password 6 In the Password recovery login token section you can download a Login Token that can be used in the event a password is forgotten We recommend that you save and store the password recovery login token file in a safe place The First Time Configuration Wizard runs The Wizard presents a number of windows in which you are prompted to configure Smart 1 Welcome The Welcome page summarizes the steps of the First Time Configuration Wizard Appliance Date and Time Setup Configure date and time in the Date and Time Setup page Click Apply Configuring Smart 1 Page 19 Using the First Time Configuration Wizard Network Connections Configure the network connections in the Network Connections page First Time Configuration Wizard Network Connections O DA O Bock Next Quit Note that in case the default IP address is changed a secondary IP address is created to preserve the current connection To edit connection properties click on the connection link Network Connections Cnew_ I J j Name lt T
29. lete all information on the appliance including images backup files and logs In This Chapter Restoring Factory Defaults using the WebUI 34 Restoring Factory Defaults using the Console 34 Restoring Using the LCD Panel 35 Restoring Factory Defaults using the WebUI Smart 1 contains a default factory image for Security Management Server To revert to an earlier image in the Smart 1 WebUI 1 Click Appliance gt Image Management 2 Select the relevant image version you wish to restore 3 Click Revert Restoring Factory Defaults using the Console The below procedure defines how to restore factory defaults using a terminal emulation program such as HyperTerminal 1 Using the supplied serial console cable to the console port connect Smart 1 to a HyperTerminal machine In the Port Settings window the setting for the Serial console is 9600 8N1 9600 BPS 8 bits no parity 1 stop bit From the Flow control drop down menu select Hardware 2 Configure the HyperTerminal parameters In HyperTerminal click Call gt Call to connect to the appliance 4 Power on Smart 1 w Page 34 Restoring Using the LCD Panel 5 While booting up the following text appears zox Ele Edit yiew Call Transfer Help Dis l3 soles l I 1 i Pri Master Disk None Display Type EGA YGA i Pri Slave Disk None Serial Port s 3F8 Sec Master Disk LBA ATA 100 80GB Parallel Port s 378 i i Sec Sl
30. lled on different sides of the firewall add a rule that allows SIC traffic between them c The version is not entered automatically if the SmartEvent version is newer than the version of the Security Management Server If so select the most recent version available from the Version drop down list d Inthe Management Software Blades list select the blades that are installed on the new host 3 Install the database on all log servers from which SmartEvent reads data select Policy gt Install Database and select the log servers as the targets 4 To allow the SmartEvent Intro server to block attacks from specific IP addresses configure the Security Management Server to accept SAM commands from the SmartEvent Intro server a On the Security Management Server edit the SCPDIR conf sic_ policy conf file Search for the section Inbound rules and add the following line under sam proxy DN Mgmt Reporting Tool ANY sam sslca b From the command line in the Security Management Server computer run the following commands cpstop cpstart Configuring the SmartEvent Clients You must perform these configurations to make the components of the SmartEvent functional After you have accomplished the tasks for SmartEvent Intro events will begin to appear in the SmartEvent Intro client After you have accomplished the tasks for SmartReporter logs will be created and sent to the SmartReporter database Reports can then be created Pa
31. n will begin at the beginning of the last file in the sequence or at the point the sequence was stopped Configuring SmartEvent Page 25 Configuring the SmartEvent Clients If you want to customize the Consolidation session refer to the SmartReporter Administration Guide for your software version on the Check Point Support Center http supportcenter checkpoint com Configuring SmartEvent Page 26 Chapter 4 Smart 1 Hardware This chapter provides instructions for installing and removing hardware components on the Smart 1 appliance In This Chapter Smart 1 5 Smart 1 25 Customer Replaceable Parts Hard Disk Drives 28 30 32 33 Page 27 Smart 1 5 Smart 1 5 This section describes the features and components located on the Smart 1 5 appliance Front Panel FPOOOOO Scan b dbs Key Description 1 LCD display screen 2 Screen operation keys 3 Console port for a serial connection to the appliance using a terminal emulation program such as HyperTerminal 4 USB ports 5 Management configuration port 6 Built in Ethernet ports Lan1 Lan4 LCD Display Screen Smart 1 appliances have an LCD screen that lets you do basic management operations You configure the management IP address net mask and default gateway using the LCD screen You can also reboot and turn off the appliance from the LCD screen To use the LCD screen operation keys Action Press Enter the main menu gt Navigate within the menu
32. of essential Smart 1 concepts and features e A step by step guide to getting Smart 1 up and running 5 Note Screen shots in this guide may apply only to the highest model to which this guide applies Shipping Carton Contents Item Description Appliance One Smart 1 appliance Rack Mounting Accessories Hardware mounting kit Cables e 1 power cable Smart 1 5 2 power cables Smart 1 25 e 1 standard LAN cable e 1 RJ 45 console cable Documentation e User license agreement e Getting Started Guide Terminology The following Smart 1 terms are used in this guide e Security Gateway The security engine that enforces the organization s security policy and acts as a security enforcement point e Security Policy The policy created by the system administrator that regulates the flow of incoming and outgoing communication e Security Management server The server used by the system administrator to manage the security policy The organization s databases and security policies are stored on the Security Management server and downloaded to the gateway Smart 1 is a Security Management server e SmartConsole GUI applications that are used to manage various aspects of security policy enforcement For example SmartView Tracker is a SmartConsole application that manages logs Introduction Page9 SmartEvent Terminology e SmartDashboard A SmartConsole GUI application that is used by the system administrator to create and manage the
33. oring Using the LCD Panel sosicseicseuds dactedendadiesesgareessulaeredeigadidaniedenceareens 35 Lights Out Management ciccicccccccccccesccecseckecccesenetiececd cecessecacieewcdenteetcnastesecdeeseeter ees 37 NDEI OCI EO iare ere a A ree E doen E EE E S 38 Initial LOgiIN e e ea aaa alec E a a aa E aE 38 Basic Configuration Options ssssseeeeeesseeeerrrerrrsstttrtrrrnrtsstrttntrnnnteseerrnernnn nenene 38 Remotely Controlling the Appliance ssossnnnneeeeseeeenerrnnresserrnrrrnrrsseerrrnrrnneessnt 38 Remotely Controlling the Power of the Appliance sssssssessssernesesesrrrerrnreessee 39 Managing LOM Card USers iiivc rcces fenced et eenteiavs cent ivwpat Rona eck Sree ete eee eee ake 39 Configuring LOM Keyboard and Mouse cceeeeeeeeeeeeeeeeeeeeeeeeneeeeeeeeeeeteeeeaaees 40 Configuring LOM Network assists icesesotsvessioctateenereneuedentecienenesnrebeshiieiereuerehe aedeneet 40 Setting the Date and TMG nah eee ela Lt ae lc at ie ee ee Mee 40 Defining a LOM Login Message si ieicecsscccic evel venient eet scenic eeeieecomcenass 40 Registration and Support cvice s 3 00ch teil heel ankeleeehets 41 PROGIS AM OP xictc sre tenae maka aE na e aE EAA elt 41 SUPPOM es ei aceite ola eal hota hlale E audi she thee 41 Where to From Here c ccecccecccecececccucecececucecececuceceeenceceeeceeneeeneeeneeeneeeneeenaes 41 Chapter 1 Introduction In This Chapter Welcome Smart 1 Overview Shipping Carton Contents
34. ou to manually change the date and time of the LOM card Defining a LOM Login Message This option enables you to define the login message that appears when accessing LOM via a browser To edit a login message 1 2 Click the Device Settings menu option and select Login Message Enter the login message text 3 Click Apply Changes Lights Out Management Page 40 Chapter 7 Registration and Support In This Chapter Registration 41 Support 41 Where to From Here 41 Registration Smart 1 requires a specific license to operate Obtain a license and register http register checkpoint com cpapp The MAC address required to obtain a license is found on the Information gt Appliance Status page of the WebUl Support For additional technical information about Check Point products consult the Check Point Support Center http supportcenter checkpoint com Where to From Here You have now learned the basics that you need to get started The next step is to obtain more advanced knowledge of your Check Point software See the relevant documentation for your software version on the Check Point Support Center Check Point documentation is available on the Check Point Support Center http supportcenter checkpoint com Be sure to also use the Online Help when you are working with the Check Point SmartConsole clients Page 41
35. port agreements do not let you replace parts unless told to do so by a technical support representative Do not open the Smart 1 case Power Supply This section presents the procedures for removing and installing a power supply unit The Smart 1 appliance contains two redundant power supplies It is not necessary to power off the appliance before adding or removing a power supply Removing the Power Supply To remove a power supply unit 1 If the power supply alarm sounds press the red alarm button to the right of the power supply This will stop the alarm 2 Remove the power cord 3 Loosen the retaining screw located above the power socket 4 Pull the extraction handle to remove the power supply unit S Note Use only the extraction handle to remove the power supply unit To prevent damaging the power supply do not pull on the retaining screw power cord clip or any other part of the unit Installing the Power Supply To install a replacement power supply 1 Insert the power supply into its slot and push firmly until it clicks into place 2 Tighten the retaining screws 3 Insert the power cord Smart 1 Hardware Page 32 Hard Disk Drives Hard Disk Drives The Smart 1 25 appliance contains two 3 1 2 hot swappable hard disk drives RAID 1 This lets you do RAID 1 mirroring across the drives using a dedicated LSI Logic RAID controller Use the SecurePlatform raidconfig command to do basic maintenance and monito
36. r bracket to one side of the appliance using three screws Repeat for the other side of the appliance Attaching the Mounting Brackets to the Slide Attach the mounting brackets to the slide You don t need to do this in the server room 1 2 3 Open the slide so it is fully extended Press the latch to extend it Identify the front end and the back end of the slide There is a piece of black plastic in the front end Attach a mounting bracket loosely to the front of a slide using two screws and two threaded washers a Close the slide so it is fully retracted b Position a mounting bracket at the front of the slide so you see three holes straight though c Insert one of the screws through the round hole closest to the front of the slide then through the slot in the bracket d Place a threaded washer on the screw Leave it slightly loose You will tighten it later e Insert one more screw through the fourth hole in the slide furthest from the front then through the slot in the bracket Mounting Smart 1 25 ina Rack Page 15 Attaching the Slide and Mounting Bracket Assembly to the Rack f Place a threaded washer on the screw Leave it slightly loose You will tighten it later Attach a mounting bracket to the back of a slide using two screws and two threaded washers a Open the slide so it is fully extended b Position a mounting bracket at the back of the slide so you see four holes straight though c Ins
37. ring procedures on your Smart 1 RAID array Usage raidconfig status rebuild extendstorage extendfs alarmon alarmoff e status Shows the status of RAID controllers and virtual disks e rebuild Rebuild degraded volumes Use this option after replacing one or more disks in the RAID array e alarmon Enable alarm sound e alarmoff Disable alarm sound Removing a Hard Disk Drive The Smart 1 25 contains 2 high capacity hard disk drive You can remove a hard disk drive without risking the integrity of the RAID array or compromising the data A Warning Removing the two hard disk drives at the same time will cause the loss of all data To remove a hard disk drive 1 Unlock the drive 2 Move the release latch toward the left 3 Remove the drive from its slot Installing a Hard Disk Drive To install a hard disk drive 1 Slide the replacement hard disk drive into the slot 2 Push the extraction handle until it closes and the drive clicks into place 3 Ifthe command raidconfig status shows that the new hard disk drive is not rebuilding run the command raidconfig rebuild to initiate the rebuild of the RAID array on the new disk drive Smart 1 Hardware Page 33 Chapter 5 Restoring Factory Defaults You may restore the factory default images on the appliance using the WebUI a console connection application such as HyperTerminal or the LCD panel A Important Restoring factory default images will de
38. rovements stability fixes security enhancements and protection against new and evolving attacks Latest Documentation The latest version of this document is at http supportcontent checkpoint com documentation_download ID 12136 For additional technical information visit the Check Point Support Center http supportcenter checkpoint com Revision History Date Description 08 December 2011 New Smart 1 25 appliance The new Smart 1 25 appliance requires a different software image than the previous appliance When accessing an image from the Download Center use the Smart 1 25B image e New LCD display and controls Front Panel on page 30 e Two high capacity disk drives with improved RAID system Hard Disk Drives on page 33 For the previous Smart 1 25 Getting Started Guide see Smart 1 5 and 25 Getting Started Guide nttp supportcontent checkpoint com documentation_download ID 10 949 23 February 2011 e Dedicated SmartEvent Server option available from R75 only Security Management Installation Type on page 20 e Improved formatting and document layout 26 January 2011 e Guide now applies to all Check Point software versions e Added Rack mounting instructions Mounting Smart 1 25 in a Rack on page 11 e Updated the First Time Configuration Wizard Instructions Using the First Time Configuration Wizard on page 18 26 August 2010 First release of the document Feedback Check Point is engaged in a continuo
39. t the new unit to the A C outlet See Removing the Power Supply on page 32 Using the First Time Configuration Wizard Perform the initial configuration of Smart 1 using the First Time Configuration Wizard At any time you can click Quit to exit the wizard Click Next to move to the next page 5 Note When running the First Time Configuration Wizard you may not see all the pages shown in this section of the guide and they may not appear in the order shown The pages that appear in the wizard and their order depend on the Smart 1 software image and on the selections that you make Page 18 Using the First Time Configuration Wizard Starting the First Time Configuration Wizard 1 Connect a standard network cable to the appliance s management interface and to your management network The management interface is marked Mgmt This interface is preconfigured with the IP address 1923168 1s 416 2 Connect to the management interface from a computer on the same network subnet as the management interface For example IP address 192 168 1 x and netmask 255 255 255 0 This can be changed in the WebUI 3 To access the management interface open a connection from a browser to the default management IP address https 192 168 1 1 4434 Ss Note Pop ups must always be allowed on https lt appliance ip address gt The login page opens 4 Log in with the default system administrator login name password admin admin and clic
40. us effort to improve its documentation Please help us by sending your comments mailto cp_techpub_feedback checkpoint com subject Feedback on Smart 1 5 amp Smart 1 25 Getting Started Guide Welcome Health and Safety Information Read the following warnings before setting up or using the appliance A Warning Do not block air vents A minimum 1 2 inch clearance is required A Warning This appliance does not contain any user serviceable parts Do not remove any covers or attempt to gain access to the inside of the product Opening the device or modifying it in any way has the risk of personal injury and will void your warranty The following instructions are for trained service personnel only To prevent damage to any system board it is important to handle it with care The following measures are generally sufficient to protect your equipment from static electricity discharge e When handling the board to use a grounded wrist strap designed for static discharge elimination e Touch a grounded metal object before removing the board from the antistatic bag e Handle the board by its edges only Do not touch its components peripheral chips memory modules or gold contacts e When handling processor chips or memory modules avoid touching their pins or gold edge fingers e Restore the communications appliance system board and peripherals back into the antistatic bag when they are not in use or not installed in the chassis Som
41. w window opens that enables you to remotely control the Smart 1 appliance Remotely Controlling the Power of the Appliance Using the LOM card it is possible to remotely switch ON the Smart 1 appliance even if the power is off switch OFF the appliance or reset the appliance Note The main power switch at the rear of the appliance must be turned ON If the switch is in the OFF position remote power management is not possible To turn ON OFF or reset the appliance 1 Click the Appliance Control menu option 2 Select Power Control the relevant option and click Apply Changes Managing LOM Card Users You can create modify and delete users You can also assign privileges to users To create a user 1 Click the LOM User Management menu option The User Management page appears 2 Select a row and click Create The User Add dialog box appears 3 Enter the following e User name a user name maximum fourteen characters e Password a password for the login name The password must have a minimum of 5 anda maximum of 14 characters e Confirm Password confirm the password e Network Privileges assign the Administrator or Operator privileges according to the table below Network Privileges Administrator Operator Login Yes Yes Enter KVM console Yes Yes Create user Yes N A Modify user Yes N A Delete user Yes N A Date time settings Yes Yes Edit login message Yes N A Remote power management Yes Yes Network setting Yes N A
42. work IPS and endpoint security with unsurpassed extensibility e Provides a comprehensive set of security management Software Blades e Maximize efficiency with a single unified management console for network and endpoint security e Reduce costs and conserve resources with up to 12 TB of built in storage capabilities e Ensure operational continuity for the most demanding environments Security Management Software Blades Smart 1 Appliances includes the following Security Management Software Blades e Network Policy Management e Endpoint Policy Management e Logging amp Status e SmartProvisioning Page 8 Shipping Carton Contents e Monitoring e User Directory e Management Portal e SmartEvent IPS Event Analysis Reporting and Event Correlation SmartEvent Smart 1 includes SmartEvent which is made up of IPS Event Analysis Reporting and Event Correlation SmartEvent provides centralized reporting and real time security event correlation and management of your security data Security teams no longer need to comb through the massive amount of data generated by the devices in their environment Instead they can focus on deploying resources on the important threats and trends that pose the greatest risk to their business You can configure Smart 1 as a Security Management server with SmartEvent In R75 and higher you can also configure Smart 1 as a dedicated server for SmartEvent This document provides e A brief overview
43. ype Member of IP Address Netmask Status Details F esthi Ethernet disabled E eth2 Ethernet disabled eth3 Ethernet disabled E ethe Ethernet disabled F eths Ethernet disabled eths Ethernet disabled eth7 Ethernet disabled E Mamt Ethernet 192 168 1 1 255 255 255 0 up You can change the Management IP address Connectivity is maintained with an automatically created secondary interface You can remove this interface after you complete the wizard in the Network gt Network Connections page Routing Table Configure the routing settings on the Routing Table page DNS and Domain Settings Set the Host Domain and DNS Servers in the DNS and Domain Settings page The host name must start with a letter and cannot be named Com1 Com2 Com9 Security Management Installation Type Note This page is only available in R75 or higher In the Installation Type page Installation Type Pa Please select one of the following options XY Security Management Supports additional management Blades Eventia Suite Dedicated server for Eventia Suite and Log Server e Security Management Configure Smart 1 as a Security Management server with all the management Software Blades including SmartEvent Configuring Smart 1 Page 20 Using the First Time Configuration Wizard e Eventia Suite SmartEvent and Reporter Suite Configure Smart 1 as a dedicated server for SmartEvent and no other