Home
        APC SURT15KRMXLT uninterruptible power supply (UPS)
         Contents
1.     Literature kit containing       Product documentation      Smart UPS RT User Manuals CD      Safety information      Warranty information    Hardware    4  Pan head screws for securing rail cleats to unit    8  Flat head screws for securing rack mount or tie brackets to unit    20  Ornamental screws       4 for securing unit to rack      16 for securing tie brackets in stack configuration    2  Cage nuts used in rack mount installation    2  Rack mount brackets    2  Rail cleats    2  Tie brackets for securing units in stack configuration    SURT192RMXLBP2 SURT192RMXLBP2J User Manual  4    Accessories    Install accessories prior to connecting power to the UPS     Refer to the APC Web site  www apc com for available accessories     Specifications    Environmental Specifications    Physical Specifications    Temperature  Operating  0   to 40   C  32   to 104   F   This unit is intended for indoor use  only  Select a location sturdy  enough to handle the weight     Do not operate unit where there is  excessive dust or temperature or  humidity are outside specified  limits     Environmental factors impact  battery life  High temperatures  poor  utility power  and frequent  short  duration discharges will shorten  battery life     Storage   15   to 30   C  5   to 86   F   charge UPS battery every six months  30   to 70   C  86   to 158   F   charge UPS battery every three months    Maximum  Elevation  Operating  3 000 m  10 000 ft     Storage  15 000 m  50 000 ft     Humidity
2.   0 to 95  relative humidity   non condensing    Weight  Refer to the Safety Guide supplied with this unit for lifting guidelines     Battery Pack  with eight battery modules  181 kg  400 lbs     without battery modules  44 kg  96 lbs     each battery module  17 kg  38 lbs     Maximum number of external battery packs  XLBPs   10  Combined weights of UPS  battery pack and  all XLBPs installed in a rack must not exceed  rack weight limits     Dimensions    Battery Pack  width  482 mm  19 in  with rack mount brackets  432 mm  17 in  without rack mount brackets    height  263 mm  10 in     depth  739 mm  29 in  with PDU  720 mm  28 in  without PDU    SURT192RMXLBP2 SURT192RMXLBP2J User Manual  5    Installation    Batteries must be removed from battery pack and XLBPs prior to installing units in  stack or rack mount configuration  Refer to instructions on packaging for details on  removing batteries from battery pack and XLBPs     Always place the UPS above the battery pack and XLBPs     Stack configuration    Rack mount configuration  Read the Safety Guide included in the package and refer to Physical Specifications in this manual  before installing the UPS     Install rails in rack  For details on rail installation refer to instructions included in rail kit package     Total stack configuration height must NOT exceed 18U  The UPS  and battery pack together equal 12U  Adding one XLBP creates an  18U configuration     For detailed instructions on installing batteries  and battery
3.  doors   refer to Rack mount configuration in this manual     Install tie brackets  Four ornamental screws  supplied in battery pack package    must be used to secure each tie bracket to the units     su0182a    8x    8x    8x    su0167a    4x  4x    external battery pack    UPS    su0166a    2x  2x    external battery pack    UPS    Install rack mount brackets  Four flat head screws  must be used to secure  each rack mount bracket  to unit     Install rail cleats  Two pan head screws must  be used to secure each rail  cleat to unit     SURT192RMXLBP2 SURT192RMXLBP2J User Manual  6    Install units in rack  Secure UPS  battery pack and XLBP in rack using cage nuts and ornamental screws included in package     Four ornamental screws and two cage nuts must be used to secure each unit     A cage nut must be used in the top hole of each rack mount bracket when securing the unit in the rack     The bottom hole of each rack mount bracket can be secured using an ornamental screw in the threaded  hole     Install and connect battery modules  Connect all eight battery modules  Failure to do so may cause equipment damage     Replace battery compartment doors  Tighten screws to secure battery compartment doors     Install bezels  There is a single latch on each side of the UPS bezel   There are two latches on each side of the battery pack and  XLBP bezels     su0183a    4x    4x    su0184a    7 holes    7 holes    su0173a    su0185a    su0186a    SURT192RMXLBP2 SURT192RMXLBP2J User Manu
4.  the range of the intended use     THERE ARE NO WARRANTIES  EXPRESS OR IMPLIED  BY OPERATION OF LAW OR OTHERWISE  OF PRODUCTS SOLD   SERVICED OR FURNISHED UNDER THIS AGREEMENT OR IN CONNECTION HEREWITH  APC DISCLAIMS ALL IMPLIED  WARRANTIES OF MERCHANTABILITY  SATISFACTION AND FITNESS FOR A PARTICULAR PURPOSE  APC EXPRESS  WARRANTIES WILL NOT BE ENLARGED  DIMINISHED  OR AFFECTED BY AND NO OBLIGATION OR LIABILITY WILL  ARISE OUT OF  APC RENDERING OF TECHNICAL OR OTHER ADVICE OR SERVICE IN CONNECTION WITH THE PRODUCTS   THE FOREGOING WARRANTIES AND REMEDIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES AND  REMEDIES  THE WARRANTIES SET FORTH ABOVE CONSTITUTE APC SOLE LIABILITY AND PURCHASER EXCLUSIVE  REMEDY FOR ANY BREACH OF SUCH WARRANTIES  APC WARRANTIES EXTEND ONLY TO PURCHASER AND ARE NOT  EXTENDED TO ANY THIRD PARTIES     IN NO EVENT SHALL APC  ITS OFFICERS  DIRECTORS  AFFILIATES OR EMPLOYEES BE LIABLE FOR ANY FORM OF  INDIRECT  SPECIAL  CONSEQUENTIAL OR PUNITIVE DAMAGES  ARISING OUT OF THE USE  SERVICE OR INSTALLATION   OF THE PRODUCTS  WHETHER SUCH DAMAGES ARISE IN CONTRACT OR TORT  IRRESPECTIVE OF FAULT  NEGLIGENCE  OR STRICT LIABILITY OR WHETHER APC HAS BEEN ADVISED IN ADVANCE OF THE POSSIBILITY OF SUCH DAMAGES   SPECIFICALLY  APC IS NOT LIABLE FOR ANY COSTS  SUCH AS LOST PROFITS OR REVENUE  LOSS OF EQUIPMENT  LOSS  OF USE OF EQUIPMENT  LOSS OF SOFTWARE  LOSS OF DATA  COSTS OF SUBSTITUENTS  CLAIMS BY THIRD PARTIES  OR  OTHERWISE     NO SALESMAN  EMPLOYEE OR AGENT 
5.  this manual     The XLBP LED remains  illuminated   A potential hardware fault exists   Contact APC  refer to Service in this manual     XLBP LED does not illuminate    On start up the XLBP LED  does not illuminate  Normal operation   No action is necessary     SURT192RMXLBP2 SURT192RMXLBP2J User Manual  9    Battery module and pair identification  The display interface will reference XLBP configuration in the following manner     Contact Information    APC Worldwide Customer Support    Customer support for this or any other APC product is available at no charge in any of the following ways         Refer to the APC Web site to access documents in the APC Knowledge Base and to submit  customer support requests         www apc com  Corporate Headquarters   Connect to localized APC Web sites for specific countries  each of which provides customer  support information         www apc com support   Global support searching APC Knowledge Base and using e support         Contact an APC Customer Support center by telephone or e mail   Local  country specific centers   go to www apc com support contact for information     Contact the APC representative or other distributor from whom you purchased your APC product for  information on how to obtain local customer support     External Battery Pack    Negative BattPair 1  Positive BattPair 2    Module 1  Module 2  Module 3  Module 4    Negative BattPair 3  Positive BattPair 4    Module 5  Module 6  Module 7  Module 8    su0178a    SURT19
6. 2RMXLBP2 SURT192RMXLBP2J User Manual  10    Maintenance  Transport  and Service    Replace battery modules  This UPS has easy to replace  hot swappable battery modules  Replacement is a safe procedure  isolated  from electrical hazards  You may leave the UPS and connected equipment on during the replacement  procedure     Once the batteries are disconnected the connected equipment is not protected from power outages     Refer to the appropriate replacement battery user manual for battery module installation instructions  See  your dealer or contact APC at www apc com for information on replacement battery modules     Service  If the unit requires service do not return it to the dealer  Follow these steps     1  Review the problems discussed in Troubleshooting in the UPS manual to eliminate common  problems     2  If the problem persists  contact APC Customer Support through the  APC Web site  www apc com         Note the model number of the unit  the serial number located on the back of the unit  and the  date purchased  If you call APC Customer Support  a technician will ask you to describe the  problem and attempt to solve it over the phone  If this is not possible  the technician will issue  a Returned Material Authorization Number  RMA           If the unit is under warranty  repairs are free         Procedures for servicing or returning products may vary internationally  Refer to the APC Web  site for country specific instructions     3  Pack the unit in its original pac
7. 990 2485B  02 2009    Smart UPS   RT    External Battery Pack    Stack Rack Mount 6U    SURT192RMXLBP2    SURT192RMXLBP2J    English    SURT192RMXLBP2 SURT192RMXLBP2J User Manual  3    Introduction    About this UPS  The American Power Conversion  APC    SURT192RMXLBP2 external battery pack  XLBP  connects to  an APC Smart UPS   RT greater than 10 kVA  Together these units provide extended protection for  electronic equipment  load  from utility power blackouts  brownouts  sags and surges  The UPS and the  XLBP together provide continuous power from the batteries until utility power returns to safe levels or the  batteries are fully discharged     The UPS and the battery pack are packaged separately     Unpack package contents  Read the Safety Guide before installing the unit     Inspect the battery pack upon receipt  Notify the carrier and dealer if there is damage     The packaging is recyclable  save it for reuse or dispose of it properly     Check the battery pack package contents     NOTE  The model and serial numbers are located on a small  rear panel label  For some models  an  additional label is located on the chassis under the front bezel          External battery pack       Front bezel       Battery compartment doors       Ground wire       Four tie brackets       Sixteen ornamental screws         Rail Kit       Four ornamental screws       Two cage nuts       Two rail cleats       Four pan head screws       Two rack mount brackets       Eight flat head screws     
8. OF APC IS AUTHORIZED TO ADD TO OR VARY THE TERMS OF THIS WARRANTY   WARRANTY TERMS MAY BE MODIFIED  IF AT ALL  ONLY IN WRITING SIGNED BY AN APC OFFICER AND LEGAL  DEPARTMENT     Warranty claims  Customers with warranty claims issues may access the APC customer support network through the Support page of the APC Web site   www apc com  Select your country from the country selection pull down menu  Open the Support tab at the top of the Web page to obtain  contact information for customer support in your region     
9. Verify that display interface shows CHRG  battery charge   is greater the 95      4   Verify that display interface shows Load is greater than 5  x the number of external battery packs installed     5   Verify that display interface shows Runtime is greater than 00hr3 3m     6   Perform a self test as described in Smart UPS user manual   If the LED remains illuminated after performing these steps  refer to the troubleshooting table below     LED Activity  Possible Cause  Corrective Action after a Self Test is  Performed    XLBP LED illuminates briefly        On start up the XLBP LED will  illuminate and blink within the first  minute       The XLBP is establishing  communication with other  components of the system       The XLBP is conducting a normal  periodic self test    Normal operation  No action is necessary     XLBP LED remains illuminated  NOTE  Read the information and perform steps outlined in the list above prior to performing the actions listed in  this table     XLBP LED is blinking slowly   one blink per second    One or more battery modules are not  connected       Check that all battery connections in the UPS   XLBP configuration are secure       Replace battery modules     XLBP LED is blinking rapidly   three blinks per second    A communication fault exists  check  cable connections      Check that all cable and battery connections  in the UPS XLBP configuration are secure       Testing beyond the self test may be required   Contact APC  Refer to Service in
10. al  7    Connect UPS  battery pack and XLBP    Units may vary in appearance from those depicted in this manual     su0189a    su0208a      Remove safety covers on  battery pack  and XLBP s      su0188a    su0190a    su0191a    UPS    Battery pack with  PDU installed    XLBP with no  PDU installed      Connect batteries as shown       Rotate safety covers      Re install safety covers   Ensure all battery  connectors used and  unused  have safety  covers installed     su0187a      Connect ground wires as shown     Ground    Ground    Ground    Thumb screw    Thumb screw     amp  Prior to connecting the battery pack to the UPS the safety cover  on the UPS battery connector must be adjusted       Loosen two thumb screws on safety cover       Slide safety cover so that battery connectors are exposed       Securely engage battery connectors       Slide safety cover to lock battery connectors in place       Tighten thumb screws     SURT192RMXLBP2 SURT192RMXLBP2J User Manual  8    Operation    Battery LED  The battery LED is located on the front bezel of the XLBP  During normal operation the LED is not  illuminated     On start up the XLBP LED will illuminate and blink within the first minute  The LED should then  extinquish     If the LED remains illuminated perform the following steps to extinguish the LED     1   Allow unit to run for two continuous hours without removing or installing batteries     2   Verify that display interface shows actual number of XLBPs connected     3   
11. ears from the date of purchase  The  obligation of APC under this warranty is limited to repairing or replacing  at its sole discretion  any such defective products  This warranty  does not apply to equipment that has been damaged by accident  negligence or misapplication or has been altered or modified in any way   Repair or replacement of a defective product or part thereof does not extend the original warranty period  Any parts furnished under this  warranty may be new or factory remanufactured     Non transferable warranty  This warranty extends only to the original purchaser who must have properly registered the product  The product may be registered at the  APC Web site  www apc com     Exclusions  APC shall not be liable under the warranty if its testing and examination disclose that the alleged defect in the product does not exist or was  caused by end user or any third person misuse  negligence  improper installation or testing  Further  APC shall not be liable under the  warranty for unauthorized attempts to repair or modify wrong or inadequate electrical voltage or connection  inappropriate on site operation  conditions  corrosive atmosphere  repair  installation  start up by non APC designated personnel  a change in location or operating use   exposure to the elements  Acts of God  fire  theft  or installation contrary to APC recommendations or specifications or in any event if the  APC serial number has been altered  defaced  or removed  or any other cause beyond
12. kaging  If this is not available         Pack the unit carefully to avoid damage in transit  Never use Styrofoam beads for packaging         Damage sustained in transit is not covered under warranty     4  Always DISCONNECT THE UPS BATTERY before shipping in compliance with U S   Department of Transportation  DOT  and IATA regulations  The battery s  may remain in the  unit     5  Mark the RMA  on the outside of the package     6  Return the unit by insured  prepaid carrier to the address given to you by Customer Support     Entire contents copyright 2008 American Power Conversion Corporation  All rights reserved  Reproduction in whole or in part without  permission is prohibited     APC  the APC logo  Smart UPS and PowerChute are trademarks of American Power Conversion Corporation  All other trademarks  product  names  and corporate names are the property of their respective owners and are used for informational purposes only     Be sure to deliver the spent battery s  to a recycling facility or ship it to APC in the  replacement battery packing material     SURT192RMXLBP2 SURT192RMXLBP2J User Manual  11    Two Year Warranty    The limited warranty provided by American Power Conversion  APC    in this statement of Limited Factory Warranty applies only to  products you purchase for your commercial or industrial use in the ordinary course of your business     Terms of warranty  APC warrants its products to be free from defects in materials and workmanship for a period of two y
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
  ITALY TERMO - BUILT IN - DSA  La nouvelle référence des tests OEA  Manual plataforma suspensa  Wiley iPad Fully Loaded  Ewent EW-110103-020-N-P  Handbuch - Olympus  CareDirector Youth User Guide  User Guide - Nelson Email Organizer  Manuale di installazione e manutenzione Elettrovalvola a 2    Copyright © All rights reserved. 