Sanyo POA-FIL131
Contents
1. 0BKL ae a Replacement Filter Cartridge Type No Service Parts No 610 334 3747 5 7 Maintenance and Care Resetting the Filter Counter Be sure to reset the Filter counter after replacing the filter and the filter cartridge 1 Press the MENU button to display the On Screen Menu Use the Point lt P buttons to move the red frame pointer to the Setting Menu icon 2 Use the Point AV buttons to move the red frame pointer to Filter counter and then press the SELECT button A dialog box appears showing the Used time option and the Scrolls remaining option Use the Point AV buttons to select Used time 3 Used time shows the total accumulated time of the Tilter use a timer setting option and the Reset option Select Reset and the Filter counter Reset appears Select Yes to continue 4 Another confirmation dialog box appears select Yes to reset the Filter counter Resetting the Scroll Counter Be sure to reset the Scroll counter after replacing the filter cartridge 1 Press the MENU button to display the On Screen Menu Use the Point lt P buttons to move the red frame pointer to the Setting Menu icon 2 Use the Point AV buttons to move the red frame pointer to Filter counter and then press the SELECT button A dialog box appears showing the Used time option and the Scrolls remaining option Use the Point AV buttons to select Scroll s remaining 3 Scroll s remaining shows the number of the remaining scro
2. 56 Maintenance and Care Filter Instructions Filter prevents dust from accumulating on the optical elements inside the projector Should the filter becomes clogged with dust particles it will reduce cooling fans effectiveness and may result in internal heat buildup and adversely affect the life of the projector This projector has an electrically operated filter which helps you to replace the filter easily The projector monitors the condition of the filter at all time and replaces a filter with a new one automatically when it detects the clogging If the projector reaches a time set in the timer setting p 55 a Filter replacement icon Fig 1 appears on the screen and the WARNING FILTER indicator on the top panel lights up p 70 When you see this icon replace the filter as soon as possible pp 29 51 and reset the Filter counter p 58 If the filter is out of scroll and the projector reaches a time set in the timer setting Fig 2 appears on the screen indicating that the filter cartridge replacement is necessary When the filter scroll is counted down to 1 the Last scroll icon Fig 3 appears on the screen indicating that there is one scroll left in the filter cartridge p 55 If the projector detects that the filter is clogged and no scroll is left in the filter cartridge a Filter cartridge replacement icon Fig 4 appears on the screen and the WARNING Fig 3 Last scroll icon FILTER indicator on the to
3. Filter cartridge replacement icon SE Fig 5 Filter replacement icon and Please wait message e Do not use the filter cartridge with other projector The filter counter and the scroll counter do not recognize the correct number of remaining scrolls of the used filter cartridge and the reset function cannot work properly It may cause a breakdown e Make sure that the projection lamp is turn off when you are replacing the filter cartridge If you replace the filter cartridge when the projection lamp is turn on the projector will be shut down automatically for safety purpose e Always reset the filter counter in the setting menu after replacing the filter If you forget to reset the filter counter the projector cannot recognize the correct number of remaining scrolls and may cause a breakdown e Do not forget to reset the filter counter and the scroll counter in the setting menu after replacing the filter cartridge If you forget to reset the filter counter and the scroll counter the projector cannot recognize the correct number of remaining scrolls and may cause a breakdown Maintenance and Care Replacing the Filter Cartridge 7 Turn off the projector and unplug the AC power cord ii from the AC outlet liter cover First clean up the dust on the projector and around the air vents the filter cover Pull out the filter cartridge When taking out the filter cartridge put your finger on the filter cartrid
4. ge s tab and then pull 3 Press A on the filter cover to release the latch and open Put the new one back into the position and close the filter cover Make sure that the filter cartridge is properly and fully inserted OO Connect the AC power cord to the projector and turn on the projector Reset the filter counter and the scroll counter p 58 CAUTION AN Make sure the filter cartridge is inserted in the projector If the filter cartridge is not inserted the projector cannot be turned on Do not put anything into the air vents Doing so may result in malfunction of the projector RECOMMENDATION We recommend avoiding dusty smoky environments when operating the projector Usage in these environments may dg cause a poor image quality O NS HHan When using the projector under dusty or smoky conditions e dust may accumulate on a lens liquid crystal panels or optical J elements inside the projector Such condition may degrade the Filter cartridge quality of the projected image Tab When the symptoms above are noticed contact your authorized dealer or service station for proper cleaning ORDER REPLACEMENT FILTER CARTRIDGE Replacement filter cartridge can be ordered through your dealer When ordering give the following information to the dealer Model No of your projector J S CHE un AIDING PLC XP100L PLC XP10
5. lls and the Reset option Select Reset and the Scroll counter Reset appears Select Yes to continue 4 Another confirmation dialog box appears select Yes to reset the Scroll counter 58 Filter counter Filter counter Pal SVGA1 Ps amp amp Ga rA A yY J ag Scroll counter Filter counter Pa SVGA1 Ps amp s on ra A kd a E Used time Scrolls remainig Select Used time and the dialogue box below appears Hour s O L 0 Select Reset and the Filter counter Reset appears Filter counter Reset T Yes then another confirmation box appears Select Yes again to reset Yes J he Filter counter Scrolls remainig g Select Scrolls remaining and the dialogue box below appears 9 seron s E Select Reset and the Scroll counter Reset appears Scroll counter Select Yes Yes then another confirmation box appears Select Yes again to reset the Scroll counter
6. p panel lights up p 70 When you see this icon replace the filter cartridge p 57 and reset the Filter counter p 58 and the Scroll counter p 58 When the filter is being scrolled using the remote control 0 29 or the Filter control function in the setting menu 0 51 a Filter replacement icon and Please wait message Fig 5 appear on the screen and the WARNING FILTER indicator blinks slow approx 2 seconds ON 2 seconds OFF p 69 The WARNING FILTER indicator blinks fast when the projector detects an abnormal condition the filter cartridge is not installed properly or the filter scroll is not working properly p 70 V Note o Fig 1 Fig 2 Fig 3 Fig 4 and Fig 5 will not appear when the Display function is set to Off p 48 during Freeze p 28 or No show p 29 o The filter cannot be rewinded e The filter can be scrolled 9 times since the filter cartridge has 10 scrolls e The filter cartridge is disposable Do not clean and reuse the filter cartridge e Do not expose the filter cartridge to water or liquid or it may cause a breakdown e Replace the filter cartridge after all the scroll is used up If you replace the filter cartridge when there are some scrolls left in the filter cartridge the filter counter and the scroll counter do not recognize the correct number of remaining scrolls and the reset function cannot work properly It may cause a breakdown O Fig 4