Home

Chief KTG230B flat panel wall mount

image

Contents

1. 100 into pole bottom 50 60 70 and tighten to secure pole and grommets 110 to surface Figure 2 Grommet installation 6 Add pipe cap 40 to top of pole Mount Assembly 7 Mount Centris head assembly or array assembly to rail following the instructions outlined in KTG 220 KTG 230 Assembly 320 And 440 Assembly section of this document 8 Place front pole clamp with Centris Head 210 against pole in approximate mounting location 9 Place three BHCS 230 into rear pole clamp 220 and place against pole aligning with front pole clamp 210 See Figure 3 Installation Instructions Figure 3 Mount Centris Head with Pole Clamp NOTE Equally tighten screws 230 against front pole mount 210 and the rear pole clamp 220 see Figure 4 Keep equal distance between mount and clamp when tightening WS Figure 4 Tightening clamp to mount 10 Secure rear pole clamp 220 to front pole mount 210 and pole by tightening three BHCS 230 using 5 32 hex key 120 See Figure 3 KTG 220 320 And 440 Assembly To assemble the KTG 220 320 and 440 NOTE If mount is being installed without the base through a flat surface proceed to Grommet Mount Installation 1 Assemble pole 50 to base 40 using one 3 8 16 x 1 FHCS 90 see Figure 2 2 Assemble pole clamp back 240 to pole mount front using two FW 250 and two BHCS 260 using a 5 32 hex key See Figure
2. 5 Model KTG Series 3 Secure pole mount back 240 to pole mount front and pole by tightening two BHCS 260 using a 5 32 hex key Pole Pole Mount front 260 Pole Clamp Back 240 Figure 5 Assemble Array Rail to Pole Display Installation Attach Centris Head to Flush Mount Display A CAUTION CAUTION If display uses a screw size other than those included in the kit DO NOT use the screws provided Using the wrong screws could result in damage to your monitor 1 Install two M4 x 12mm Phillips pan head screws 160 into two upper mounting holes in display back see Figure 6 NOTE DO NOT fully tighten at this time 2 Hang display on Centris head see Figure 7 Install bottom two M4 x 12mm Phillips pan head screws 160 through Centris head mounting holes and into lower mounting holes in display back 4 Tighten ALL four M4 x 12mm Phillips pan head screws 160 see Figure 8 Model KTG Series Display Figure 8 Secure Display to Centris Bracket Installation Instructions Attach Centris Head to Recessed Mount Display NOTE Refer to Table 1 to select the applicable screw and spacer combination Uninstall end lock using the 5 32 hex key 120 see Figure 9 2 Remove Centris head from array rail 20 30 Centris Head Square Nut ESV Dy A N Ex XS LK LL AN mma LESS A SS a End Lock Centris Head Figure 10 Slide Centris Bracket
3. INSTALLATION INSTRUCTIONS Horizontal And Vertical Table Stands and Accessories Model KTG Series The KTG Series is a free standing pole mount solution for multiple displays BEFORE YOU BEGIN A CAUTION To prevent damage to the Kit which could affect or void the Factory warranty and to the equipment that will be attached to it thoroughly study all instructions and illustrations before you begin the installation If you have any questions about this installation contact Chief Manufacturing Chief is a trademark of Milestone AV Technologies All rights reserved E 8832 000188 RevG AN Chief Manufacturing a products division 2010 Milestone AV Technologies a iC lal of Milestone AV Technologies Duchossois Group Company 8401 Eagle Creek Parkway Savage MN 55378 www chiefmfg com P 800 582 6480 952 894 6280 F 877 894 6918 952 894 6918 03 10 Our Mounts Your Vision Model KTG Series Installation Instructions TOOLS REQUIRED FOR INSTALLATION e Drill and 1 2 drill bit larger if mounting through a flat surface and using cable management e Phillips Head Screw Driver e 3 4 Wrench e 3 32 Hex Key provided e 5 32 Hex Key provided e 7 32 Hex Key provided INSPECT MOUNT BEFORE ASSEMBLY Carefully inspect components for shipping damage If damage is apparent call your carrier claims agent and do not continue with installation until the carrier has reviewed the damage se
4. Slide Centris bracket with display left or right until properly positioned on array rail 3 Tighten Centris bracket rear adjustment knob Horizontal Adjustment Figure 14 Display Horizontal Adjustment Model KTG Series Display Pitch and Roll Adjustment To adjust display pitch or roll position 1 Loosen Centris bracket front adjustment knob see Figure 15 2 Tilt display up or down or adjust display roll left or right until properly positioned 3 Tighten Centris bracket front adjustment knob Pitch Roll Adjustment CABLE MANAGEMENT The KTG Series mount includes cable management features used to properly route and secure display cables To use the cable management features 1 Connect cables to display 2 Route cables through cable clips on array rail 3 Route cables down pole and away from mount and secure to pole using sheath 80 Installation Instructions Cable Clips ia MEEN ALLL Figure 16 Cable Management
5. e Figure 1 Installation Instructions Model KTG Series Table 1 Parts 9 CENTRIS HERD ASSEMBLY Poe Won ARRAY ASSEMBLY Duel 7 PRECARTTOD Pou Feesans1 QUANTITY By MODEL O O N O POLE Freestand 42 SHEATH Cable Management 8 1 220 I B a a a EE EE E E EE ES EE B a ana T EN EE 190 SPACER Nylon 3 8 used with item 170 00 SPACER Nylon 3 4 used with item 180 NO _h 260 SCREW Button Head Cap 1 4 20 x 3 4 2 Indicates an available optional accessory not included with above models For additional information pertaining to available accessories contact a Chief Customer Service represenatative or visit us at www chiefmfg com Quantity varies depending upon the number of displays being installed Model KTG Series Installation Instructions 10 Includes 210 220 230 60 70 Figure 1 Parts ASSEMBLY AND INSTALLATION 50 60 70 Grommet Mount Installation To install on a flat surface 1 Locate desired point on surface where mount is to be 1 2 dia installed see Figure 2 through hole 2 Drill a 1 2 dia hole through surface Slide one 3 8 16 x 6 HHCS 100 upward through lower grommet 110 through hole in surface and through upper grommet 110 4 Place pole 50 60 70 onto upper grommet 110 aligning threaded hole in pole bottom with threaded end of 3 8 16 x 6 HHCS 100 5 Thread 3 8 16 x 6 HHCS
6. off Array Rail Place display face down on a clean dry surface Place four 3 8 or 3 4 nylon spacers 190 or 200 over four mounting holes in display back see Figure 11 Align Centris head mounting holes with four nylon spacers see Figure 11 Secure Centris head to display using four M4 x 20mm Phillips pan head screws 170 or four M4 x 30mm Phillips pan head screws 180 see Figure 11 Installation Instructions Phillips Pan Head Screw 170 or 180 es Spacer 190 or 200 Centris Head Display Figure 11 Mount Centris Bracket to Display 7 Slide display with Centris bracket onto array rail 20 30 see Figure 12 NOTE Repeat previous steps for each additional display 8 Reinstall end locks into mounting rail using the 5 32 hex key 120 see Figure 13 Display with Centris Bracket Figure 12 Mount Display with Centris Bracket to Array Rail Model KTG Series Lf ioe 75 j HA n KA x ANAA w End Lock Retaining Screw Centris Head Figure 13 Reinstall End Lock s ADJUSTMENTS Display Adjustment The KTG Series mount allows horizontal pitch and rotational adjustment of each display The KTG Series mount also allows a full 360 deg of display rotation with a maximum pitch range of 15 up and 15 down Display Horizontal Position Adjustment To adjust display horizontal position 1 Loosen Centris bracket rear adjustment knob see Figure 14 2