Home
Smeg KI90C-1 cooker hood
Contents
1. ELECTRICAL CONNECTION Connect the hood to the mains through a two pole switch having a contact gap of at least 3 mm Remove the grease filters see paragraph Maintenance being sure that the connector of the feeding cable is correctly inserted in the socket placed on the side of the fan Connect the control connector Cmd Place the connectors in the junction box 24 and close it using the 2 screws 12e 2 9 x 9 5 provided Fix the junction box to the hood body using the 2 screws 12c 2 9 x 6 5 provided For the recirculation version fit the activated carbon odour filter Refit the grease filters USE L KOOD S Vi 3 Light Switches the lighting system on and off S Led Motor running led 1 Motor Switches the extractor motor on and off at low speed Used to provide a contin uos and silent air change in the presence of light cooking vapours V2 Speed Medium speed suitable for most operating conditions given the optimum treated air flox noise level ratio V3 Intensive Maximum speed used for eliminating the highest cooking vapour emission including long periods MAINTENANCE Grease filters CLEANING METAL SELF SUPPORTING GREASE FILTERS The filters must be cleaned every 2 months of operation or more frequently for particularly heavy usage and can be washed in a dishwasher Remove the filters one at a time by pushing them towards the back of the group
2. ance MAINTENANCE lt Switch off or unplug the appliance from the mains supply before carrying out any maintenance work Clean and or replace the Filters after the specified time period Fire hazard Clean the hood using a damp cloth and a neutral liquid detergent The symbol x on the product or on its packaging indicates that this product may not be treated as household waste Instead it shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment By ensuring this product is disposed of correctly you will help prevent potential negative consequences for the environment and human health which could otherwise be caused by inappropriate waste handling of this product For more detailed information about recycling of this product please contact your local city office your household waste disposal service or the shop where you purchased the product CHARACTERISTICS Dimensions 5 Y oO 130 oO 8 g cN 898 350 e 0150 l nm a 698 290 Components Ref Q ty Product Components 2 1 1 Hood Body complete with Controls Light Blower Filters 2 1 Telescopic Chim
3. SUGESTOES 58 CARACTERISTICAS 29 INSTALA O UTILIZAC O 65 MANUTENCAO 66 aa a 67 SADE NI Marre SADE NOS ai INNEHALL 76 EGENSKAPER ANVANDING pan RECOMMENDATIONS AND SUGGESTIONS Instructions for Use apply to several versions of this appliance Accord ingly you may find descriptions of individual features that do not apply to your specific appliance INSTALLATION The manufacturer will not be held liable for any damages resulting from in correct or improper installation The minimum safety distance between the cooker top and the extractor hood is 650 mm some models can be installed at a lower height please re fer to the paragraphs on working dimensions and installation Check that the mains voltage corresponds to that indicated on the rating plate fixed to the inside of the hood For Class appliances check that the domestic power supply guarantees adequate earthing Connect the extractor to the exhaust flue
4. ese gt Libretto Istruzioni Instructions Manual Manuel d Instructions Bedienungsanleitung Gebruiksaanwijzing Manual de instrucciones Manual de Instru es Bruksanvisning KI90C 1 INDICE CONSIGLIE SUGGERIMENTI R S A S CARATTERISTICHE RECOMMENDATIONS AND SUGGESTIONS CHARACTERISTICS INSTAEEATON AARNA ONAN aw h acu ten aaa Saa sa 16 SOMMAIRE 5 15 5066 5 0 22 CARACTERISTIQUES INSTALLATION UTILISATION suqya INHALTSVERZEICHNIS EMPFEHLUNGEN UND HINWEISE 31 5 BEDIENUNG INHOUDSOPGAVE ADVIEZEN EN SUGGES TIES 40 INSTALLATIE GEBRUKK D n Ou wa Q Suysa us NDICE CONSEJOS SUGERENCIAS u as aan 49 CARACTERISTICAS NDICE CONSELHOS
5. and pulling down at the same time Wash the filters taking care not to bend them Allow them to dry before refitting When refitting the filters make sure that the handle is visible on the outside Activated charcoal filter Recirculation version REPLACING THE ACTIVATED CHARCOAL FILTER The filter is not washable and cannot be regenerated and must be replaced approximately every 4 months of operation or more frequently for particularly heavy usage Remove the metal grease filters Remove the saturated activated carbon filter by releasing the fixing hooks Fit the new filter by hooking it into its seating Refit the metal grease filters Lighting LIGHT REPLACEMENT 20 W halogen light Remove the 2 screws fixing the Lighting support and pull it out of from the Hood Extract the lamp from the Support Replace with another of the same type making sure that the two pins are properly inserted in the lamp holder socket holes Refit the Support fixing it in place with the two screws re moved as above
6. at the activated charcoal filters have been inserted Flue assembly Mounting the hood body Position the upper chimney section and fix the upper part to the frame using the 2 screws 12c 2 9 x 6 5 provided Similarly position the lower chimney section and fix the lower part to the frame using the 2 screws 12c 2 9 x 6 5 pro vided Recirculation version Make sure that the outlet of the extension pieces 14 1 is hori zontally and vertically aligned with the chimney outlets Otherwise remove the lower chimney and adjust the position by inverting the extension pieces for air outlet connection 14 1 or by cutting the hood body extension piece 14 if any along one of the chases destined to the predetermined extension lengths Replace then the elements as earlier described Fit the directional grids 8a 8b in their housings making sure that the directional symbols are towards the top Also make sure that they are correctly inserted in the connection exten sion pieces 14 1 Before fixing the hood canopy to the frame Screw the 2 screws 12f half way into the holes provided in the sides of the bottom of the frame Remove the grease filters from the hood canopy Remove any activated charcoal filters Lift the hood canopy and engage the screws 12f in the slots A as far as they will go Working from below fix the hood canopy to the frame B using the 4 screws 124 and 4 washers 22 provided then tighten all the screws securely
7. den beam ceilings drill according to the wood screws used For wooden shelf drill 7 mm For the power supply cable feed drill 10 mm For the air outlet Ducted Version drill according to the diameter of the external air ex haust duct connection Insert two screws of the following type crossing them and leaving 4 5 mm from the ceiling For concrete ceilings use the appropriate plugs for the screw size not provided for Cavity ceiling with inner space with wall thickness of approx 20 mm Screws 12h supplied For wooden beam ceilings use 4 wood screws not provided For wooden shelf use 4 screws 12g with washers 22 and nuts 23 provided Fixing the frame Loosen the two screws fastening the lower chimney and re move this from the lower frame Loosen the two screws fastening the upper chimney and re move this from the upper frame If you wish to adjust the height of the frame proceed as follows Unfasten the metric screws joining the two columns located at the sides of the frame Adjust the frame to the height required then refit all the screws removed as above Insert the upper chimney stack from above and leave it run ning free on the frame Lift up the frame fit the frame slots onto the screws up to the slot end positions Tighten the two screws and fasten the other two screws pro vided with the hood Before tightening the screws completely i
8. ney comprising 2 1 1 Upper Section 2 2 1 Lower Section 7 1 1 Telescopic frame complete with extractor consisting of 1 Upperframe 740 1 Lower frame 8 1 Right Air Outlet Grill 8b 1__LeftAir Outlet Grill 9 1 Reducer Flange 0 150 120 mm 10 1 Damper Optional 14 1 Hood Air Outlet Extension Piece consisting of two Half Shells Optional 14 1 1 Air Outlet Connection Extension 15 1 Air Outlet Connection 24 1 Junction box 25 Pipe clamps not included Ref Installation Components 11 4 Wall Plugs 10 12 6 Screws 2 9 x 6 5 12e 2 Screws 2 9 x 9 5 12f 2 Screws x 80 12g 24 Screws M6 x 80 12h 4 Screws 5 2 x 70 14 24 Screws 3 5 9 5 21 1 Drilling template 22 8 6 4 dia washers 23 4 Q ty Documentation 1 Instruction Manual INSTALLATION Drilling the Ceiling shelf and fixing the frame DRILLING THE CEILING SHELF Use a plumb line to mark the centre of the hob on the ceiling support shelf Place the drilling template 21 provided on the ceiline support shelf making sure that the template is in the correct position by lining up the axes of the template with those of the hob Mark the centres of the holes in the template Drill the holes at the points marked For concrete ceilings drill for plugs appropriate to the screw size For hollow brick ceilings with wall thickness of 20 mm drill 10 mm immediately insert the Dowels 11 supplied For woo
9. t is possible to adjust the frame by turning it Make sure that the screws do not come out of their seats in the slotted holes The frame mountings must be secure to withstand the weight of the hood and any stresses caused by the occasional side thrust applied to the device On completion check that the base is stable even if the frame is subjected to bending In all cases where the ceiling is not strong enough at the sus pension point the installer must provide strengthening using suitable plates and backing pieces anchored to the structurally sound parts Ducted version air exhaust system Connection When installing the ducted version connect the hood to the chimney using either a flexible or rigid pipe 0 150 or 120 mm the choice of which is left to the installer To install a 0 120 mm air exhaust connection insert the ducer flange 9 on the hood body outlet Fix the pipe using the pipe clamps 25 not provided Remove any activated charcoal filters RECIRCULATION VERSION AIR OUTLET Push fit connection 15 onto the hood body outlet Insert the connection extension pieces laterally 14 1 in connec tion 15 Make sure that the outlet of the extension pieces 14 1 is hori zontally and vertically aligned with the chimney outlets If this is not the case adjust the position by either reversing the con nection extension pieces 14 1 and then reassemble as described previously Ensure th
10. through a pipe of minimum diame ter 120 mm The route of the flue must be as short as possible Do not connect the extractor hood to exhaust ducts carrying combustion fumes boilers fireplaces etc If the extractor is used in conjunction with non electrical appliances e g gas burning appliances a sufficient degree of aeration must be guaranteed in the room in order to prevent the backflow of exhaust gas The kitchen must have an opening communicating directly with the open air in order to guarantee the entry of clean air USE The extractor hood has been designed exclusively for domestic use to elimi nate kitchen smells a Never use the hood for purposes other than for which it has been designed lt 650 mm min Neverleave high naked flames under the hood when it is in operation Adjust the flame intensity to direct it onto the bottom of the pan only making sure that it does not engulf the sides Deep fat fryers must be continuously monitored during use overheated oil can burst into flames Do not flamb under the range hood risk of fire This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concern ing use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appli
Download Pdf Manuals
Related Search
Related Contents
Anleitung - ViewSonic PO4053 - Interface de Rede PROFIBUS-DP 現場説明書 STEVAL-MKI062V2, iNEMO™ (iNErtial MOdule) demonstration Rollei CT-5A 平成13年函審第9号 漁船第五十八妙力丸火災事件 言渡年月日 平成 RIMBOU Lotus MANUAL Centrale antintrusione senza fili mod. HELIOS MANUALE TECNICO Copyright © All rights reserved.