Home
CyberPower PR750LCDRM1U uninterruptible power supply (UPS)
Contents
1. berPower Reliability Quality Value Smart App Sinewave Series PR750LCDRM1U PR1000LCDRM1U User s Manual K01 0000059 04 IMPORTANT SAFETY WARNINGS This manual contains important instructions that should be followed during installation and maintenance of the UPS and batteries Please read and follow all instructions carefully during installation and operation of the unit Read this manual thoroughly before attempting to unpack install or operate CAUTION The UPS must be connected to a grounded AC power outlet with fuse or circuit breaker protection DO NOT plug the UPS into an outlet that is not grounded If you need to de energize this equipment turn off and unplug the UPS CAUTION DO NOT USE FOR MEDICAL OR LIFE SUPPORT EQUIPMENT CyberPower Systems does not sell products for life support or medical applications DO NOT use in any circumstance that would affect operation or safety of any life support equipment with any medical applications or patient care CAUTION The battery can energize hazardous live parts inside even when the AC input power is disconnected CAUTION For pluggable equipment the socket outlet shall be installed near the equipment and shall be easily accessible CAUTION To prevent the risk of fire or electric shock install in a temperature and humidity controlled indoor area free of conductive contaminants Please see specifications for acceptable temperature and humidity range CAUTION To reduce t
2. REAR PANEL DESCRIPTION 3 2y1 1 Power Switch Master on off switch for equipment connected to the UPS 2 Power On Indicator Indicates the power is on 3 LCD Module Display a LCD shows all the UPS information with icons and messages _ oo A k ve ik 1 lh i oO i_o JLo jiLo jiLo ji_o l a _iO 8 e 4 LCD Display Toggle Button The button can be used to toggle between different data displays on the LCD 5 Battery Backup Protected Outlets Provides eight battery powered surge protected and AVR outlets for connected equipment and ensures temporary uninterrupted 8 USB port operation of connected equipment during a power failure USB communication port for management software Critical Non critical 9 Serial Port When the UPS is overloaded the circuit breakers will be tripped Serial port allows connection and communication between the UPS and the to interrupt the power supply to the uncritical outlets while computer 10 SNMP HTTP Network slot Remove the cover panel to install optional RMCARD that allows remote monitoring and control your UPS on networks 11 Site Wire Fault Indicator This LED will illuminate to warn the user that a wiring problem exists within the AC receptacle such as a bad ground missing ground or reversed wiring If illuminated disconnect all equipment and contact an electrici
3. printer copier space heater vacuum paper shredder or other large electrical device into the UPS The power demands of these devices will overload and possibly damage the unit 4 Plug the UPS into a 2 pole 3 wire grounded receptacle wall outlet Make sure the wall branch outlet is protected by a fuse or circuit breaker and does not service equipment with large electrical demands e g air When you first receive the unit plug in the unit to fully charge the battery conditioner refrigerator copier etc Avoid using extension cords 5 Depress the power switch to turn the unit on The power on indicator light will illuminate If an overload is detected an audible alarm will sound and the unit will emit one long beep To correct this turn the UPS off and unplug at least one piece of equipment from the battery power supplied outlets Wait 10 seconds Make sure the circuit breaker is depressed and then turn the UPS on 6 Your UPS is equipped with an auto charge feature When the UPS is plugged into an AC outlet the battery will automatically recharge 7 To maintain optimal battery charge leave the UPS plugged into an AC outlet at all times 8 To store your UPS for an extended period cover it and store with the battery fully charged battery every three months to ensure battery life 9 Professional Rack Mount UPS provides one serial port one dry contact and one USB port to allow connection and commun
4. misuse or alteration of either the product or the Connected Equipment 5 CyberPower excludes any liability for personal injury under the Limited Warranty and Connected Equipment Guarantee CyberPower excludes any liability for direct indirect special incidental or consequential damages whether for damage to or loss of property EXCEPT FOR AND ONLY FOR the specific limited agreement of CyberPower to provide certain warranty benefits regarding Connected Equipment under this Warranty loss of profits business interruption or loss of information or data NOTE Some States or Provinces do not allow the exclusion or limitation of incidental or consequential damages so the above limitation may not apply to you 6 The Product is not for use in high risk activities or with aquariums The Product is not designed or intended for use in hazardous environments requiring fail safe performance or for use in any circumstance in which the failure of the Product could lead directly to death personal injury or severe physical or property damage or that would affect operation or safety of any medical or life support device collectively High Risk Activities CyberPower expressly disclaims any express or implied warranty of fitness for High Risk Activities or with aquariums CyberPower does not authorize use of any Product in any High Risk Activities or with Aquariums ANY SUCH USE IS IMPROPER AND IS A MISUSE OF THE PRODUCT What is the Fine Print The ap
5. that is lost as a result of the failure or the restoration of data or records or the reinstallation of software 2 This Warranty does not cover or apply to misuse modification operation or storage outside environmental limits of the Product or the equipment connected to it nor for damage while in transit or in storage nor if there has been improper operation or maintenance or use with items not designed or intended for use with the Product such as laser printers appliances aquariums medical or life support devices etc What Other Limitations Apply 1 This Warranty does not apply unless the Product and the equipment that was connected to it were connected to properly wired and grounded outlets including compliance with electrical and safety codes of the most current electrical code without the use of any adapters or other connectors 2 The Product must have been plugged directly into the power source and the equipment connected to the Product must be directly connected to the Product and not daisy chained together in serial fashion with any extension cords another Product or device similar to the Product surge suppressor or power tap Any such installation voids the Limited Warranty 3 The Product and equipment connected to it must have been used properly in a suitable and proper environment and in conformance with any license instruction manual or warnings provided with the Product and the equipment connected to it 4 The Produ
6. 0LCDRM1U PR1000LCDRMI1U stabilizes inconsistent utility power The incoming utility power may be damaging to important data and hardware but with Automatic Voltage Regulation the computer will not experience damaging voltage levels An Automatic Voltage Regulator automatically increases low or decreases high voltage to a consistent computer safe 110v 120v The unit powerful sealed lead acid batteries will provide power only if the incoming voltage drops below 80v or increases above 150v SYSTEM BLOCK DIAGRAM EMI Input Output Suppressor Charger AC DC Inverter gt Normal Mode Battery Mode HARDWARE INSTALLATION GUIDE 1 Your new UPS may be used immediately upon receipt However recharging the battery for at least four hours is recommended to ensure that the battery s maximum charge capacity is achieved Charge loss may occur during shipping and storage To recharge the battery simply leave the unit plugged into an AC outlet The unit will charge in both the on and off position 2 If you will use the software connect the serial interface cable to the serial port on the UPS and the computer If you would like to use USB cable please connect the USB cable on the UPS then connect the USB cable to your computer 3 With the UPS unit off and unplugged connect your computer monitor and any externally powered data storage device Hard drive Tape drive etc into the battery power supplied outlets DO NOT plug a laser
7. MENT PROCEDURE 2 Remove the two retaining screws of the cable protection cover then remove the cover 1 Remove the right side front panel 3 Disconnect the black and red cable 5 4 Remove the one retaining screws 5 Charge a new battery pack Assemble the screws cover cable and front panel in the reverse sequence of above steps Recharge the unit for4 8 hours to ensure the UPS performs expected runtime Line mode UPS Status Display Capacity Display pans Input Output a a a x Digital Value Display Select SW of Load of Battery Battery Mode UPS Status Display Capacity Display oa gon Input Output ae 4 m epee PT Digital Value Display Select SW 0 Press of Load of Battery retu rn Press gt 4sec sound disable Press gt 4sec again sound enable overload V illuminated X Not illuminated either LCD SETUP FUCTIONS Set up Mode Step 1 The machine enters Set Up Mode after holding the Display toggle for 10 seconds Icon 3 4 5 6 7 8 lights to indicate Set Up Mode Step 2 By pressing the Display toggle users can switch between setup functions User configurable functions are as follows a Delay Time The time delay between switching from Battery Mode to Line Mode There are 9 different settings The default setting is 0 minutes b Battery Pack Numbers This function provides the estimated UPS runtime using various numbers of battery
8. an to ensure outlet is properly wired 12 EPO Emergency Power Off port The interface can be used to connect to switches for emergency power off continuing to supply the critical outlets As well as the battery capacity depletes under the threshold value the uncritical outlets will be shut down and provide energy for critical outlets The threshold can be determined and set by users Non critical outlets can also be turned on off manually through the software package provided 6 Input Power Cord Heavy duty extra long power cord 7 Input Circuit Breaker Resettable circuit breakers provide Input optimal overload Protection BATTERY REPLACEMENT Contact your dealer or email tech cpsww com Refer to replacement battery pack number RBP 422 for PR750LCDRM1U PR1000LCDRM1U Read and follow the IMPORTANT SAFETY INSTRUCTIONS before servicing the battery Service the battery under the supervision of personnel knowledgeable of batteries and their precautions Servicing the battery should only be performed by trained personnel Replacement of batteries located in an OPERATOR ACCESS AREA CAUTION When replacing batteries replace with the same number of the following battery HR9 6 BB for PR750LCDRM1U PR1000LCDRM1U CAUTION Risk of Energy Hazard 6V maximum 9 Ampere hour HR9Q 6 batteries Before replacing batteries remove conductive jewelry such as chains wrist watches and rings High energy through conductive materials could cause se
9. ct must have been used at all times within the limitations on the Product s VA capacity What are the Limitations The sole and exclusive remedies of the Initial Customer are those provided by this Warranty The Product was designed to eliminate disrupting and damaging effects of momentary less than 1ms voltage spikes or impulses from lightning or other power transients If it can be shown that a voltage spike lasting longer than 1ms has occurred the occurrence will be deemed outside the rated capabilities of the Product and the Limited Warranty is void CyberPower Does Not Cover or Undertake Any Liability in Any Event for Any of the Following 1 Loss of or damage to data records or software or the restoration of data or records or the reinstallation of software 2 Damage from causes other than AC Power Line Transients spikes or surges on properly installed grounded and code compliant 120 volt power lines in the United States and Canada transients surges or spikes on standard telephone land lines PBX telephone equipment lines or Base 10T Ethernet lines when properly installed and connected This exclusion applies for example to fluctuations in data transmission or reception by CATV or RF transmission or fluctuations or by transients in such transmission 3 Damage from any circumstance described as excluded above with respect to the Product 4 Damages from fire flood wind rain rising water leakage or breakage of plumbing abuse
10. does not perform expected runtime PowerPanel Personal Edition is inactive The unit is not providing battery power The serial cable is not the cable that was provided with the unit You must use the cable included with the unit for the software Additional troubleshooting information can be found at www cyberpowersystems com support htm TECHNICAL SPECIFICATIONS Model PR750LCDRM1U PR1000LCDRM1U Capacity Watts 560 750 Input Input Voltage Range Input Frequency Range Output On Battery Output Voltage Pure Sine Wave at 120Vac 7 On Battery Output Frequency 50 60 1 Transfer Time Typical Overload Protection On Utility Circuit Breaker On Battery Intemal Current Limiting Surge Protection and Filtering Output Receptacles SSS eee ee ee Dimensions cm Weight Kg 17 6 18 0 Battery ood Maintenance Free Lead 6V 9 0AHX4 Acid Battery 80Vac 150Vac 50 60Hz 3Hz auto sensing Hot Swappable Extemal Battery Yes Warning Diagnostics Indicators Power On Wiring Fault LCD Display Using Battery AVR Load Level Battery Level Audible Alarms Environmental Operating Temperature 32 F to 104 F 0 Cto40 C On Battery Low Battery Overload Operating Relative Humidity 0 to 95 Non Condensing wee POnemr anal Busness eg Windows 98 ME NT 2000 XP Vista Management Self Test Manual Self Test COM Interface True RS232 x1 SNMP HTTP Network Slot UL1778 cUL107 FCC Doc Class B Safety Appro
11. e for packaging and shipment and you must pay the cost of the repair estimate How Long Do I Have To Make A Claim All claims must be made within ten days of the occurrence What Will We Do To Correct Problems CyberPower will inspect and examine the Product If the Product is defective in material or workmanship CyberPower will repair or replace it at CyberPower s expense or if CyberPower is unable to or decides not to repair or replace the Product if defective within a reasonable time CyberPower will refund to you the full purchase price you paid for the Product purchase receipt showing price paid is required If it appears that our Product failed to protect any equipment plugged into it we will also send you forms for making your claim for the connected equipment We will repair or replace the equipment that was damaged because of the failure of our Product or pay you the fair market value NOT REPLACEMENT COST of the equipment at of the time of the damage We will use Orion Blue Book or another a third party valuation guide or eBay craigslist or other source to establish that amount Our maximum liability is limited to 400 000 for PR750LCDRM1U PR1000LCDRM1U Who Pays For Shipping We pay when we send items to you you pay when you send items to us What Are Some Things This Warranty Does Not Cover 1 This Warranty does not cover any software that was damaged or needs to be replaced due to the failure of the Product or any data
12. east 4 hours E ee a g Unit has been damaged by a Contact CyberPower Systems about replacement batteries at surge or spike tech cpsww com Uncritical outlets have turned off automatically due to an overload Note If the machine is left idle for over 30 seconds during setup it will turn off the backlight and return to general mode automatically Circuit breaker has tripped due to an overload to equipment Push the toggle button to make the uncritical outlets turn on Battery not fully charged Recharge the battery by leaving the UPS plugged in Battery is degraded Contact CyberPower Systems about replacement batteries at tech cpsww com The onon switeh Is designed Turn the UPS off Wait 10 seconds and then turn the to prevent damage by rapidly turning it off and on AUN it i ted t f The UPS will not turn on The upitie nol fonnagiad to The unit must be connected to a 110 120v outlet an AC outlet ntact P tems about replacement batteries at Te baieie wont out Contact CyberPower Systems ut replaceme eries tech cpsww com_ Mechanical problem Contact CyberPower Systems at tech cpsww com The serial cable or USB cable Connect the cable to the UPS unit You must use the cable that is not connected came with the unit The cable is connected to the Try another port of your computer wrong port Shutdown your computer and turn the UPS off Wait 10 seconds and turn the UPS back on This should reset the unit The UPS
13. es 1 Reorient or relocate the receiving antenna 2 Increase the separation between the equipment and receiver 3 Connect the equipment into an outlet on a circuit different from that to which the receiver is connected 4 Consult the dealer or an experienced radio TV technician for help Any special accessories needed for compliance must be specified in the instruction The Class B digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulation Cet appareil numerique de la class B respecte toutes les exigencies du Reglement sur le materiel brouilleur du Canada
14. he risk of electric shock do not remove the cover except to service the battery There are no serviceable parts inside except for the battery CAUTION To avoid electrical shock turn off the unit and unplug it from the AC power source before servicing the battery or installing a computer component CAUTION DO NOT USE WITH OR NEAR AQUARIUMS To reduce the risk of fire do not use with or near aquariums the aquarium can come in contact with metal electrical contacts and cause the machine to short out CAUTION DO NOT USE WITH LASER PRINTERS The power demands of laser printers are too large for a UPS INSTALLING YOUR UPS SYSTEM UNPACKING Inspect the UPS upon receipt The box should contain the following 1 UPS Unit 1 User s Manual for UPS 2 Rack mount Brackets 1 Emergency Power Off Cable gray 1 PowerPanel Business Edition Software CD 1 Serial Interface Cable DB 9 1 USB A B type cable 1 Warranty Registration Card Condensation from OVERVIEW The PR750LCDRM1U PR1000LCDRM1U provides automatic voltage regulation for inconsistent utility power The PR750LCDRM1U PR1000LCDRM1U features 1874 Joules of surge protection and provides battery backup during power outages The PR750LCDRM1U PR1000LCDRM1U ensures consistent power to your computer system and its included software will automatically save your open files and shutdown your computer system during a utility power loss AUTOMATIC VOLTAGE REGULATOR AVR The PR75
15. ication between the UPS and computers or equipment This allows the simultaneous shutdown of two computer systems Serial port II produces the basic information for equipment that can utilize a dry contact ups The Primary computers with PowerPanel Business Edition installed are the computers that you will use to control the UPS and make any changes to the operation of the UPS When there is a power failure the computer which connects to Primary port will start to shutdown after a user controlled delay PowerPanel Business Edition will save and close any open files prior to shutting the system down 10 EPO Emergency Power Off Port The feature is for the application to enable emergency power shutdown Use the gray cable provided to connect the UPS to a normally closed or normally open contact switch according to the circuit diagram EPO function is provided in the UPS EPO remote switch which is a Push Back button installed computer room outside by a phone line and not connected any other equipment Recharge the Unplug the unit and turn Power Off when first connecting your computer and peripherals OPTION 1 USER SUPPLIED NORMALLY CLOSED SWITCH 4 5 JUMPER ee N C EPO SWITCH ERE t eel E The Computer Install PowerPanel Business Edition OPTION 2 USER SUPPLIED NORMALLY OPEN SWITCH 1 felt ea RJ11 PLUG f N O EPO SWITCH RJ11 PLUG NO CONNECTION BASIC OPERATION FRONT
16. packs The default setting is 0 c Static Frequency Tolerance There are 6 settings The default setting is 6 Functional description The setting may be adjusted to the quality of the electricity in use d Slew rate also called Dynamic Frequency Tolerance The fault value is 4 Functional Description Slew Rate indicates the tolerance of a device in accepting frequency variance The lower Slew Rate results in less tolerance but better protection for the connected loads e Battery Shutdown Voltage This function adjusts the UPS shutdown point according to the battery voltage The settable items are sorted by unit as in the following table Step 3 Press and hold the toggle for 4 seconds When the icons blink the value of items i O Ue each item can be changed by slightly pressing the toggle Step 4 To save the value and return to general mode press and hold the toggle for Delay Time 4 seconds Battery Pack Numbers Static Frequency Tolerance Slew Rate Battery Shutdown Voltage Note If user wants to return to general mode without saving changes there are two methods 1 Wait for the backlight to turn off 2 Press and hold the Display toggle for 10 seconds TROUBLE SHOOTIMG O rmn roca OOOO o O O Turn the UPS off and unplug at least one piece of equipment Wait 10 seconds reset the circuit breaker by depressing the button and then turn the UPS on Batteries are discharged Recharge the unit for at l
17. plication of the United Nations Convention of Contracts for the International Sale of Goods is expressly excluded CyberPower is the warrantor under this Limited Warranty For further information please feel free to contact CyberPower at Cyber Power Systems USA Inc 4241 12th Ave E STE 400 Shakopee MN 55379 call us at 877 297 6937 or send us an e mail message at claims cpsww com FCC Notice This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation WARNING This equipment has been tested and found to comply with the limits for a Class B Digital Device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measur
18. rs defects in materials and workmanship in the Product under normal use and conditions It also covers equipment that was connected to the Product and damaged because of the failure of the Product What is the Period of Coverage This warranty covers the Product for three years and connected equipment for as long as you own the Product Who Is Covered This warranty only covers the original purchaser Coverage ends if you sell or otherwise transfer the Product How Do You Get Service 1 Call us at 877 297 6937 or write to us at Cyber Power Systems USA Inc 4241 12th Ave E STE 400 Shakopee MN 55379 or send us an e mail message at claims cpsww com for instructions 2 When you contact CyberPower identify the Product the Purchase Date and the item s of Connected Equipment Have information on all applicable insurance or other resources of recovery payment that are available to the Initial Customer and Request a Claim Number 3 You must provide a dated Proof of Purchase receipt or other proof of the original purchase and provide a description of the defect 4 Pack and ship the product with a dated Proof of Purchase receipt to CyberPower and if requested the item s of Connected Equipment a repair cost estimate for the damage to the Connected Equipment and all claim forms that CyberPower provides to you Show the Claim Number on the shipping label or include it with the product You must prepay all shipping costs you are responsibl
19. vals CYBERPOWER GREENPOWER UPS TECHNOLOGY GreenPower UPS The CyberPower GreenPower UPS cuts UPS energy costs by up to 75 compared to the conventional UPS circuits Conventional UPS systems pass power through a transformer to provide normal output voltage to protected devices By contrast the GreenPower UPS circuitry bypasses the transformer when utility power is normal significantly increasing the power efficiency of the UPS As a result a GreenPower UPS produces less heat and uses less energy reducing energy costs When utility power is abnormal the GreenPower UPS operates like a normal UPS Since utility power operates normally 88 of the time the GreenPower UPS operates primarily in its cost cutting bypass mode LIMITED WARRANTY AND CONNECTED EQUIPMEN GUARNTEE Read the following terms and conditions carefully before using the CyberPower PR750LCDRM1U PR1000LCDRM1U the Product By using the Product you consent to be bound by and become a party to the terms and conditions of this Limited Warranty and Connected Equipment Guarantee together referred to as this Warranty If you do not agree to the terms and conditions of this Warranty you should return the Product for a full refund prior to using it ENERGY SAVING TECHNOLOGY Who is Providing this Warranty CyberPower Systems USA Inc CyberPower provides this Limited Warranty What Does This Warranty Cover This warranty cove
20. vere burns CAUTION Risk of battery explosion if battery is replaced by an incorrect type Dispose of used battery according to the instructions CAUTION To reduce the risk of fire connect only to a circuit provided with 20 amperes maximum branch circuit overcurrent protection in accordance with the National Electric Code ANSI NFPA 70 CAUTION Use only the specified type of battery See your dealer for replacement batteries CAUTION The battery may present the risk of electrical shock Do not dispose of batteries in a fire as they may explode Follow all local ordinances regarding proper disposal of batteries CAUTION Do not open or mutilate the batteries Release electrolyte is harmful to the skin and eyes and may be toxic CAUTION A battery can present a high risk of short circuit current and electrical shock Take the following precautions before replacing the battery 1 Remove all watches rings or other metal objects 2 Only use tools with insulated handles 3 Do not lay tools or metal parts on top of battery or any terminals 4 Wear rubber gloves and boots 5 Determine if the battery is inadvertently grounded If inadvertently grounded remove source of ground CONTACT WITH A GROUNDED BATTERY CAN RESULT IN ELECTRICAL SHOCK The likelihood of such shock will be reduced if such grounds are removed during installation and maintenance applicable to a UPS and a remote battery supply not having a grounded circuit BATTERY REPLAC
Download Pdf Manuals
Related Search
Related Contents
機械設備工事一般仕様書 Manual - Logic RC 6809795R3 HFC User Manual CC Axis OfficeBasic USB Wireless G Fiche de données de sécurité conformément au règlement - Sobre o modelo da BVS GOT-5100T-830 ZyXEL WAC6502D-E Copyright © All rights reserved.
Failed to retrieve file