Home
Fantec TC-400R8A
Contents
1. power from 5V and 12V amp 3 3V shall not exceed 375W 2 Noise Test Noise bandwidth is from DC to 20 MHz 3 Ripple frequencies greater than 1MHz shall be attenuated by the measurement System 4 Add 0 1uF 10uF capacitor at output connector terminals for ripple and noise measurements Pgl 2 3 PS ON Remote On Off Control When PS ON is pulled to TTL Low the DC output is to be enabled When PS OFF is pulled to TTL high the DC output is to be disabled 2 4 PW OK PW OK is power good signal and should be asserted high by the power supply to indicate that 5 VDC and 3 3VDC output are above the under voltage thresholds of the power supply TTL compatible signal out with 100ms to 500ms TE Basen PW OK Sense Lever 95 of Timing of PS ON PW OK and Germane Voltage Rails Although there is no requirement to meet specific timing parameters The following signal timings are recommended 2ms lt T2 lt 200ms 100ms lt T3 lt 500ms T4 gt I1ms T5 10ms 2 5 Efficiency 67 at full load Normal Line 2 6 Hold Up Time 16ms at maximum load amp normal input voltage 3 PROTECTIONS 3 1 OVER VOLTAGE PROTECTION Standard on 5 0V output set at 6 25VDC 075VDC 3 2 SHORT CIRCUIT PROTECTION A short circuit placed between the DC Return and the output shall cause No damage and the power supply shall shutdown Pg2 3 3 OVER POWER PROTECTION The power supply shall s
2. 5 fa gt I STAR COMPUTER CO LTD Ic I STAR Dual AC Mini Redundant Power Supply 400W 400W for IPC Computer Model No TC 400R8A Table of content 1 Introduction ote eme Ud ode ee ee neos d den 1 2 Specification 2 1 Input Voltage ee tritt ete eo pr men ge ee tete GE 1 2 2 DC Output errorem e cere re E eret iue rer Weg teu die 1 2 3 PS ON Remote ON OFP cccccccccccsescceeseseceeeeesecseeeseeseeeeeeeees 2 2 4 PW OK power good signal seen 2 Died FGTICICNCY M 2 2 6 Hold Up Tame ee inside eene te RRR RAM eaten eee 2 3 PROTECTION 3 1 Over Voltage protection sess 2 3 2 Short Circuit Protection c cccccccccccsssscccessseeccessseeeeesesseeeeeceesseeses 2 3 3 Over Power Protection rmrrnnnnrrnnannnvrrrrnnnvrnrrnnnvrnrrnnnnrnrrnnnnnnnrvennvene 3 3 4 No Load operation ronvronnvnonvnonrnevrnnvrnnernnenrnenvnnnrannvrnsnsrsenenenenenenn 3 4 Environment Temperature serie re enata rta ek b rh ot rb 3 5 Reliability oooroorrooorororrronrorovorovonnvrrnnvenrvrsnvrenvvennvrnnnnnnnssnrsennssnnvennnennne 3 6 Agency approvals sees ener etnneennn entren 3 7 EMURLEL z eerte eere EN e t e eom ineo tha 3 8 Instructions ober eno enar etie pce i ARS 3 9 HOT SWAP Procedures eene 4 10 PINOUTS of connectors sssssssessseeeneeenene eee 4 Color Reference for LED cable oronnronnvronvrrn
3. OM SVDC SVYDC 3VDC 5 D0 COM Main Power Connector Fin Phe cow GJE c com EEG zvoc com KE m 12v06 com 12vo8 12V 8P Power Connector Pad OEI sec g 2v0C 12V Power Connector COM N 12VDC COM Peripheral Power Cannector Fin ce SYNE cc COM c CON Fins fr J 12WNC Floppy Drive Power Connector 12v yellow 42VSB brown amp v white 15V red aS ON gary 174 blue 2 2v purple PAR OK orange UOM black 11 DIMENSION TC XXXR8A L200 x W150 x H 86 mm I i 928989 gt K 2888 ar al 83008 0 m A ie E 9 9 L e 9 9 150 00 200 00 86 00 T o o i o foo Pg5
4. hut down when output power exceeds 130 to 160 of full load and require a power on cycle be performed by the operate 3 4 NO LOAD OPERATION No parts shall be damaged on the power supply 4 ENVIRONMENT TEMPERATURE 4 1 Operation Temperature 0 C to 50 C 4 2 Cooling By forced air 4 3 Storage Temperature 20 C to 70 C 4 4 Humidity 5 to 90 non condensing 5 RELIABILITY 5 1 MTBF OF POWER SUPPLY ELECTRONIS 100 000 hours at full load and 25 C ambient temperature 5 2 LIFE EXPECTANCY OF FAN 40 000 hours at 40 C 6 AGENCY APPROVALS UL 1950 QQGQ2 UL 1950 QQGQ8 TUV Rheinland EN60950 IEC950 mod CB Certification 7 EMI RFI FCC part 15 Subpart B Class B EN55022 CISPR22 Class B CE Make EN61000 3 3 1995 EN61000 4 2 3 4 5 6 8 11 8 INSTRUCTIONS The set still works properly even if either unit is removed The removed unit can t be used in other machinery nor for other purpose When one unit breaks down it s LED will blink buzzer will sound Push the Reset button and buzzer will stop REDUNDANCY Offer redundant function for power system and mutually backs up the outputs A zero transfer time when backup takes place HOT SWAP The power system provides a Hot Swap function This means when either one of the redundant power supplies fails or breaks down you can easily replace failed unit without any interference to the system Pg3 BUZZER warning buzzer sounds when any one of the power supplies fails The warning bu
5. vrrnnvrerrrrnvrrnvrrnnnrnnnrnnne 4 Main Power Connector essent enne 5 11 Dimension scseeeeeeeeeeeenn nennen enne enmet emet enr esses esses teens eee 5 1 Introduction The 400R8A Series products of Hot Swap amp Power Sharing redundant Power supply provides increased reliability when integrated a variety of Systems The 400R8A series is ideally suited to telecommunications and Industrial system as well as a variety of other applications where system Never shut down i E Zero down time TC 400R8A series redundant power supply it consists of x One of passive Back plane One of exothermal enclosure Two of compact size power modules with Hot Pluggable connector made by Germany Screw package x Alarm reset bottom Features Dual AC IN Put design AC 1 be Master source AC 2 be second source Dual AC PANTEN Taiwan USA Germany China PS 2 Size design x Hot Swappable amp Power Sharing capability Patent no 136053 Auto Select AC input 2 Specification 2 1 AC Input Voltage 90 to 132 or 180 to 264 auto selectable 47Hz 63 Hz 2 2 DC Output 400W maximum VOLTAGE 5V 12V 3 3V 12V 5V 5Vsb MAX LOAD 35A 18A 24A 0 8A 0 5A 2A MIN LOAD 3A 2A 0 3A 0 1A 0 1A 0 1A REGULATION t5 t5 t5 10 10 t5 RIPPLE mV 50 120 50 120 50 50 Note 1 The combined total power from 45V and 3 3V shall not exceed 175W The combined total
6. zzer is reset table from reset switch either the one in front control panel or the one on the rear side LED S The warning LED S can be found either on the rear side or the control panel of the power system Tells if one of the two power supplies has failed by LED blinking HOT PLUGGABLE _ The power system provides a Hot Pluggable function This method allows the power units in the Disk Array File Server to be removed or inserted very easily without 9 HOT SWAP PROCEDURES Please refer to the followings when either one power supply unit is fount defective A Locate the defective power supply by examining the individual LED on the power unit or the LED on the front control panel if LED is Blinking B Unlock amp Remove the defective power supply unit C Replace a new GOOD power supply unit Insert the power supply into the power system chassis in position amp it will auto Lock up D Turn on the new power supply unit E Check the module LED which indicate the power and LED of total power system status Both LED shall Have steady life 10 PINOUTS OF CONNECTORS 7x 5 25 1 x 3 5 1 x ATX 24Pin or 20Pin for motherboard 1 x 8Pin Power Connector 1 x 12V Power Connector Color Reference for LED cable POWER I LED Cable Brown with POWER 2 LED Cable Red with MAIN POWER LED Cable Green with Pg4 5 3VD0C 5 AVN0 COM 5MDC COM EVDC CON FWRLUDK 5v5n 1312vDC 412VDC 13 3VDC 3 WNC 12VDC Om PG ONS CG CON C
Download Pdf Manuals
Related Search
Related Contents
CD Radio Cassette manual Streamliner M user manual Ficha técnica Dextrion G5 manuale di utilizzo e manutenzione brushless blender n°62 LiteFENCE Mobile - IT - Manuale di installazione IC-F3102D/F4102D Manual PRO-SEOUL15 (Page 1) Progression January 2014 - East London Advanced Motorcyclists Copyright © All rights reserved.
Failed to retrieve file