Home
        Intel AXXBASRAIL13 mounting kit
         Contents
1.  The inner slides must be positioned all the way forward in the rails to ensure proper  installation of the server     2  Engage the matching rails and slide the server chassis into the rack  see letter    B    in  Figure 5  until the two safety stops lock into position  see letter  C  in Figure 5               AF000631    Figure 5  Installing the Server Chassis into the Rack    6 Basic Rail Kit Install Guide for Intel   Server Chassis    Rail Kit Installation Instructions    3  Depress the two safety locks  one on each side   See letter    A    in Figure 6   4  Slide the server chassis all the way into the rack  See letter  B  in Figure 6     5  Use the rack screws  778 32 x 3 4  to secure the chassis and rack handles into the rack   See letter  C  in Figure 6              AF000630    Figure 6  Installing the Server Chassis into the Rack    Basic Rail Kit Install Guide for Intel   Server Chassis 7    Rail Kit Installation Instructions    8 Basic Rail Kit Install Guide for Intel   Server Chassis    
2.  at http   support intel com support   motherboards server sb cs 010770 htm     Wichtige Sicherheitshinweise    Lesen Sie zun  chst s  mtliche Warnund Sicherheitshinweise in diesem Dokument  bevor  Sie eine der Anweisungen ausf  hren  Beachten Sie hierzu auch die Sicherheitshinweise zu  Intel Serverplatinen und Servergeh  usen auf der Intel  Server Deployment Toolkit CD  oder unter http   support intel com support motherboards server sb cs 010770 htm     Consignes de s  curit      Lisez attention toutes les consignes de s  curit   et les mises en garde indiqu  es dans ce  document avant de suivre toute instruction  Consultez Intel Server Boards and Server  Chassis Safety Information sur le  ntel   Server Deployment Toolkit CD ou bien rendez   vous sur le site http   support intel com support motherboards server sb cs 010770 htm     Instrucciones de seguridad importantes    N          Lea todas las declaraciones de seguridad y precauci  n de este documento antes de realizar  cualquiera de las instrucciones  Vea Intel Server Boards and Server Chassis Safety  Information en el Intel   Server Deployment Toolkit CD y o en http   support intel com   support motherboards server sb cs 010770 htm        EITHER A Z BU  BMAP ARRAREN FHS   http   support  intel com support motherboards server sb CS 010770 htm EA Intel Server  Boards and Server Chassis Safety Information    Intel IRSOEBERSMRSBVAZE  fig                               Basic Rail Kit Install Guide for Intel   Server Chassis i
3.  death may occur  Intel may make changes to specifications and product descriptions at any time   without notice     Intel   server boards contain a number of high density VLSI and power delivery components that need adequate  airflow for cooling  Intel s own chassis are designed and tested to meet the intended thermal requirements of these  components when the fully integrated system is used together  It is the responsibility of the system integrator that  chooses not to use Intel developed server building blocks to consult vendor datasheets and operating parameters to  determine the amount of airflow required for their specific application and environmental conditions  Intel  Corporation can not be held responsible if components fail or the server board does not operate correctly when used  outside any of their published operating or non operating limits     Intel  Intel Pentium  and Intel Xeon are trademarks or registered trademarks of Intel Corporation or its subsidiaries in  the United States and other countries       Other names and brands may be claimed as the property of others   Copyright    2008  Intel Corporation  All Rights Reserved    ii Basic Rail Kit Install Guide for Intel   Server Chassis    Safety Information    Important Safety Instructions    Read all caution and safety statements in this document before performing any of the  instructions  See also Intel Server Boards and Server Chassis Safety Information on the  Intel  Server Deployment Toolkit CD and or
4.  inner rail from the rail assembly  See letter  C  in Figure 2                             AF000627    Figure 2  Removing the Inner Rail from the Rail Assembly    Basic Rail Kit Install Guide for Intel   Server Chassis 3    Rail Kit Installation Instructions  Install Outer Rail Slides to Rack Posts    1  Attach the outer rail slides to the rack posts using two 48 32 x 1 2 screws at the front  posts  and two 28 32 x 1 2 screws at the rear posts  See letter    A    in Figure 3   Note  The rail flanges mount to the inside of each post                                                           AF000628    Figure 3  Installing the Outer Rail Slides to the Rack Posts    Basic Rail Kit Install Guide for Intel   Server Chassis    Rail Kit Installation Instructions    Attach Inner Rails to Server Chassis Sidewalls    1  Insert the inner rails over the server chassis sidewall studs  See letter    A    in Figure 4   2  Slide the inner rails toward the front of the server chassis  See letter  B  in Figure 4     3  Secure the inner rails with one   6 32 x 1 4 screw for each rail  See letter    C    in  Figure 4        AF000629    Figure 4  Attaching the Inner Rails to the Server Chassis Sidewalls    Basic Rail Kit Install Guide for Intel   Server Chassis    Rail Kit Installation Instructions    Install the Server Chassis into the Rack    1  Align the inner rails  attached to the server chassis  with the outer rail assemblies   attached to the rack   See letter    A    in Figure 5     Note 
5. 6  Installing the Server Chassis into the Rack    7    Basic Rail Kit Install Guide for Intel   Server Chassis vii    List of Figures    viii Basic Rail Kit Install Guide for Intel   Server Chassis    1 Rail Kit Installation Instructions    Use the instructions in this installation guide to install the AXXBASRAIL13 rail kit to  one of the following Intel   products       Intel   Server Chassis SR1500    Intel   Server Chassis SR1550    Intel   Server Chassis SR1600    Intel   Server Chassis SR1625    Intel   Server Chassis SR2400    Intel   Server Chassis SR2500    Intel   Server Chassis SR2600    Intel   Server Chassis SR2625    Intel   Server System SR1560SF    Before You Begin    Before installing the rail kit  observe these safety guidelines   1  Turn off all peripheral devices connected to the server     2  Turn off the server by pressing the power button on the front of the chassis  Then  unplug the AC power cord s  from the chassis or wall outlet     3  Label and disconnect all peripheral cables and all telecommunications lines connected  to I O connectors or ports on the back of the chassis     4  Provide electrostatic discharge  ESD  protection by wearing an anti static wrist strap  attached to a chassis ground   any unpainted metal surface   when handling  components     Tools and Supplies Needed      Phillips   cross head  screwdriver   1 bit and  2 bit       Anti static wrist strap and conductive foam pad  recommended     Basic Rail Kit Install Guide for Intel   S
6. Basic Rail Kit Install Guide for  Intel amp  Server Chassis   A Guide for Technically Qualified Assemblers of Intel  Identified Subassemblies   Products   Intel  Server Chassis SR1500   Intel  Server Chassis SR1550   Intel  Server Chassis SR1600   Intel  Server Chassis SR1625   Intel  Server Chassis SR2400   Intel  Server Chassis SR2500   Intel  Server Chassis SR2600   Intel  Server Chassis SR2625    Intel  Server System SR1560SF    Intel Order Number  D59599 003  Rev  02                                                                                                                                                                   Disclaimer    Information in this document is provided in connection with Intel   products  No license  express or implied  by  estoppel or otherwise  to any intellectual property rights is granted by this document  Except as provided in Intel s  Terms and Conditions of Sale for such products  Intel assumes no liability whatsoever  and Intel disclaims any  express or implied warranty  relating to sale and or use of Intel   products including liability or warranties relating to  fitness for a particular purpose  merchantability  or infringement of any patent  copyright or other intellectual property  right  Intel products are not designed  intended or authorized for use in any medical  life saving  or life sustaining  applications or for any other application in which the failure of the Intel product could create a situation where  personal injury or
7. able  provide some ESD protection by  wearing an antistatic wrist strap attached to chassis ground any unpainted metal surface on  your server when handling parts     ESD and handling boards  Always handle boards carefully  They can be extremely  sensitive to ESD  Hold boards only by their edges  After removing a board from its  protective wrapper or from the server  place the board component side up on a grounded   static free surface  Use a conductive foam pad if available but not the board wrapper  Do  not slide board over any surface     Installing or removing jumpers  A jumper is a small plastic encased conductor that slips  over two jumper pins  Some jumpers have a small tab on top that you can grip with your  fingertips or with a pair of fine needle nosed pliers  If your jumpers do not have such a  tab  take care when using needle nosed pliers to remove or install a jumper  grip the  narrow sides of the jumper with the pliers  never the wide sides  Gripping the wide sides  can damage the contacts inside the jumper  causing intermittent problems with the  function controlled by that jumper  Take care to grip with  but not squeeze  the pliers or  other tool you use to remove a jumper  or you may bend or break the pins on the board     iv Basic Rail Kit Install Guide for Intel   Server Chassis    Contents    Contents    Safety Information E iii  Important Safety Instructions eism  t iii  Wichtige Sicherheitshinweise AEN iii  Mrapiisp  Es  N  be                            
8. erver Chassis 1    Rail Kit Installation Instructions    Kit Content List  AXXBASRAIL13   Each Rack Mount Kit contains the following     Note  The two included rail assemblies are NOT interchangeable  Each is installed into the rack  by its orientation  right or left  when standing in front of the rack  The right rail assembly  is identified with a BLUE  RH  sticker and the left rail assembly is identified with a  GREEN  LH  sticker     Note  This kit includes two sets of 8 32x 1 2  screws  One set of eight has a larger screw head  size than the second set of eight  Use the set of 8 32x1 2    screws that best fits the rack in  which the rail kit is being installed       Outer Rail Slide Assembly  2   See letter    A    in Figure 1      Inner Rail Slide  2   See letter    B    in Figure 1      Rail Safety Stop  one each on inner slides   See letter  C  in Figure 1     Outer Slide Rail Screws  8 48 32 x 1 2   See letter    D    in Figure 1      Inner Slide Rail Screw  8 46 32 x 1 4   See letter    D    in Figure 1    e Rack Screws  2 28 32 x 3 4   See letter    D    in Figure 1        AF000626    Figure 1  Rail Kit Components    2 Basic Rail Kit Install Guide for Intel   Server Chassis    Rail Kit Installation Instructions    Installation Instructions    Remove the Inner Rail from the Rail Assembly    1  Extend the inner rail until it locks  See letter    A    in Figure 2   2  Depress the spring safety lock to release the inner rail  See letter  B  in Figure 2     3  Remove the
9. ii    Safely Information    Warnings    Heed safety instructions  Before working with your server product  whether you are  using this guide or any other resource as a reference  pay close attention to the safety  instructions  You must adhere to the assembly instructions in this guide to ensure and  maintain compliance with existing product certifications and approvals  Use only the  described  regulated components specified in this guide  Use of other products    components will void the UL listing and other regulatory approvals of the product and  will most likely result in noncompliance with product regulations in the region s  in which  the product is sold     System power on off  The power button DOES NOT turn off the system AC power  To  remove power from system  you must unplug the AC power cord from the wall outlet   Make sure the AC power cord is unplugged before you open the chassis  add  or remove  any components     Hazardous conditions  devices and cables  Hazardous electrical conditions may be  present on power  telephone  and communication cables  Turn off the server and  disconnect the power cord  telecommunications systems  networks  and modems attached  to the server before opening it  Otherwise  personal injury or equipment damage can  result     Electrostatic discharge  ESD  and ESD protection  ESD can damage disk drives   boards  and other parts  We recommend that you perform all procedures in this chapter  only at an ESD workstation  If one is not avail
10. iii  Instrucciones de seguridad importantes                       ssssseeeseeen menn iii   Rail Kit Installation Instructions                                eeeeeeee eee ee Lceeeeeeeeeeee eene 1  Before You BegiN                                      1   Tools and Supplies Needed                        sess seen enne nennen nnn enn nnn tenerent rennen nene 1  Kit Content List  AXXBASRAJIL139    2    ierra cena senatui denar re ek nau dr nad Ra AR 2  Installation Instructions                    ssssssse mme nennen nnne nnne nnne 3  Remove the Inner Rail from the Rail Assembly AAA 3  Install Outer Rail Slides to Rack Posts                     sssessessssessseeseeeeeenee nnne eene nnn 4  Attach Inner Rails to Server Chassis Sidewalls                           eesssseeeeeennnnns 5  Install the Server Chassis into the Rack                   ssssssssssssesseeeeeeneee enne eene nnne 6    Basic Rail Kit Install Guide for Intel   Server Chassis V    Contents    vi    Basic Rail Kit Install Guide for Intel   Server Chassis    List of Figures    List of Figures    Figure 1  Rail Kit Components            ecsici necs nent rtkhn tana nn ink una a nR tk ne cra Fu SR CER RR REN Rapids 2  Figure 2  Removing the Inner Rail from the Rail Assemblv  A 3  Figure 3  Installing the Outer Rail Slides to the Rack Poet    4  Figure 4  Attaching the Inner Rails to the Server Chassis Sidewalls                                           5  Figure 5  Installing the Server Chassis into the Rack    6  Figure 
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
PowerTraveller PMEV2001 mobile device charger  Modo de empleo Mantenimiento ¿Qué hacer?  OPENCOCKPITS IOCard USBRELAYS MANUAL DE INSTALACION  FICHA DATOS TÉCNICOS AR C.C. 30%  Cahier n° 4 : Accompagner une PME dans son  CDA WF250SS User's Manual    SXS500M2: Back Up Alarm  Spin and Learn Top Manual  NuTiny-SDK-NUC123 User Manual    Copyright © All rights reserved. 
   Failed to retrieve file