1. erSure Personal 450 700 1250 VA 230V Technical Support U S A 1 800 222 5877 Outside the U S A 614 841 6755 U K 44 0 1793 553355 France 33 0 1 43 60 01 77 Germany 49 89 99 19 220 Italy 39 02 98250 1 Netherlands 31 0 475 503333 E mail upstech liebert com Web site http Awww liebert com Worldwide FAX tech support The Company Behind The Products With more than 1 000 000 installations around the globe Liebert is the world leader in computer protection systems Since its founding in 1965 Liebert has developed a complete range of support and protection systems for sensitive electronics Environmental systems close control air conditioning from 1 5 to 60 tons Power conditioning and UPS with power ranges from 250 VA to more than 1000 kVA e Integrated systems that provide both environmental and power protection in a single flexible package Monitoring and control on site or remote from systems of any size or location Service and support through more than 100 service centers around the world and a 24 hour Customer Response Center 12 4 614 841 5471 While every precaution has been taken to ensure accuracy and completeness of this literature Liebert Corporation assumes no responsibility and disclaims all liability for damages resulting from use of this information or for any errors or omissions 1999 Liebert Corporation All rights reserved throughout th
2. Contact your dealer PS PXT inglese qxd 6 06 2001 9 51 Pag 9 COMMUNICATIONS You can use MultiLink Software to allow your UPS to communicate to your computer via your DB 9 communications port A MultiLink Software CD is included in the box or you can download it from our web site at www liebert com The PowerSure Personal XT UPS contains a standard DB 9 receptacle located on the rear of the UPS unit Several signals are provided on this port and are assigned as follows L BIN ASSIGNMENT DESCRIPTION Low Battery open collector No connection No connection Remote Shutdown 5 12V on battery operation Common Remote Shutdown short to pind any mode operation Low Battery open emitter AC Fail open emitter AC Fail open collector 10 IN ID O OO N PIN Assigment The DB 9 communication port allows the status of UPS to be monitored e data to be backed up computer to be switched off MAINTENANCE The PowerSure Personal XT UPS requires very little maintenance The batteries are valve regulated nonspillable lead acid and require that they be kept charged to obtain their designed life When connected to the mains supply the battery is continuously charged When storing the UPS for any length of time it is recommended to plug in the UPS for at least 24 hours every four to six months to ensure full recharge of the batteries Battery disposal Wh
3. 1 5 Inspect the packaging carton and its contents for damage Please inform the trasport agency immediately should you find signs of damage Please keep the packaging in a safe for future use Plug the UPS into a wall outlet see figure 1 Let the UPS charge the battery for at least 2 hours You may use the UPS while the battery charges but the UPS backup time will be reduced until the battery is fully charged It will take up to 8 hours to charge the fully discharged battery To start up the UPS press the On Off switch When the UPS start it will beep an both LEDs of the front panel will light up for 2 seconds The green light up continuously This indicates normal operation Note If the UPS continues to beeps or the green light is not alight even mains power is available please see the chapter Troubleshooting for more information Switch off the equipment you want to protect and connect it to the outlets of the UPS Switch on the protected equipment one piece per time BATTERY MODE OPERATION Battery mode occurs in event of extreme input mains conditions or a complete mains failure During Battery mode the Mains Battery LED green will flash every 4 seconds and an alarm will sound every 4 seconds This will change to a beep every second when the battery runs low approximately 2 minutes remaining WARNING Turning off the UPS while in Battery mode will result in loss of output power PS PXT inglese qxd 6 06 2
4. must be rated between 10 20 amperes When using the communication features on the UPS ensure the cabling connected to the DB9 communication port or the network connection are kept separated by 25mm from the power leads to the UPS input and output p PS PXT inglese qxd 6 06 2001 9 51 Paoi 3 These units bear TUV GS mark CE mark and comply with the following standards limits value class B EN 60950 1998 8 EN 50091 1 1994 4 EMI RFI EN550222 class B EMS IEC 1000 4 2 ESD Level 3 IEC 1000 4 3 RS Level 3 IEC 1000 4 4 EFT Level 3 IEC 1000 4 5 Lightning surge Level 3 CAUTION Although your UPS has been designed and manufactured to assure personal safety improper use can result in electrical shock or fire To insure safety please observe the following rules a Turn off and unplug your UPS before cleaning Do not use liquid or aerosol cleaners A dry cloth is recommended to remove dust from the surface of your UPS Do not install or operate your UPS in or near water Do not place UPS on an unstable cart stand or table Do not place UPS under direct sunlight or close to heat emitting sources Do not place UPS power cord in any area where it may get damaged by heavy objects a Follow all warnings and instructions marked on the UPS Do not attempt to service the UPS as it has no user serviceable parts inside Refer all repairs to qualified service personnel ATTENTION Turn off and unplug your UPS f
5. repeat the steps in the installation section of this manual If the problem persists refer to the chart below PROBLEM POSSIBLE CAUSE No indication no beep even UPS is connected to mains power supply No input voltage Check building wall outlet and mains cable by connecting another device with cable to this wall outlet Fuse has been melt Replace fuse by fuse with same rating Green LED blinks red LED off 1 beep every 4 sec Mains power failure Wait until mains power recovers UPS input power cord not plugged in Make sure the power cord is connected Power cord defective Please contact your dealer Grenn LED blinks red LED off 1 beep every sec very low battery voltage Plug the UPS into a working wall outlet for at least 8 hours to recharge the batteries If the problem still rmains the UPS will not operate during power failure or it will turn off immediately In this case contact your dealer Grenn LED lights up red LED blinks 2 beep every 2 sec Battery cannot be charged Please contact your dealer Grenn LED lights up red LED blinks 1 beep every half sec The power required from the equipments is too high Remove equipment until the UPS stops beeping Green LED off red LED lights up continuous beeps Output short circuit Remove alla off the equipments and contact your dealer Overload exceeds 120 Reduce the load UPS fault
6. 001 9 51 Paoi Z LED amp ALARMS The front panel LEDs and audio beeps indicate the UPS status Switch and LEDs Symbol Function On off D Turn the UPS system an and off 1 Steady Input power is acceptable the UPS is in normal mode online Status LED 2 Blinking Input power is out of green tolerance the UPS is battery mode 3 Off No input power or the battery is exhausted or the UPS is switched off 1 Blinking The UPS is overloaded or Fault LED A has failed at battery test red 2 Steady UPS fault Switch and LEDs Function Beep continuously Starting up the UPS for 2 sec 1 beep every 4 sec Power failure UPS is battery mode 1 beep every sec Battery low UPS is in battery mode batteries are nearly axhausted and UPS will be shut down 1 beep every 2 sec Battery weak UPS is normal mode online battery is not fully charged backup time during power failure shorter than nominal value 3 beep every 2 sec Battery replacement battery needs to be replaced 2 beep every 2 sec Charger fault UPS cannot recharge the battery See chapter Troubleshooting for more information 1 beep every half Overload See chapter Troubleshooting for more information sec Continuous Fault please contact your dealer PS PXT inglese qxd 6 06 2001 9 51 TROUBLESHOOTING If the UPS fails to operate properly turn off the unit and
7. PS PXT inglese qxd 6 06 2001 9 51 Pagi 1 W Liebert Keeping Business in Business 450 700 1250 VA 230V Powersure Personal XT User MANUAL English enmen Fran ais italiano Espa ol PS PXT inglese qxd 6 06 2001 9 51 Paoi 2 IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS This manual contains important safety instructions that should be followed during the installation and maintenance of the UPS and its batteries Please read this manual thoroughly before attempting to install or operate this UPS This equipment can be installed and operated by individuals without previous training 1 PowerSure Personal XT models are available for 230VAC supply voltages and loads Please verify that this model matches your AC mains load voltage requirements This equipment is designed for Commercial Industrial use only Liebert Corporation neither recommends nor knowingly sells this product for use in critical life support applications The PowerSure Personal XT 230VAC models are not supplied with an input power lead for connection to the mains supply Use the input mains power lead from your data processing equipment to connect the UPS to the mains supply The UPS is supplied with two output power leads with moulded connectors to connect from the UPS output to your equipment Additional input output leads can be obtained from your dealer Also provided is a Liebert spec
8. e world Specifications subject to change without notice Liebert and the Liebert logo are registered trademarks of Liebert Corporation All names referred to are trademarks or registered trademarks of their respective owners SLI 23265 5 99 Rev 0 p
9. en the battery life is expended see alarm indications dispose of the discarded batteries in accordance with local environmental laws p PS PXT inglese qxd 6 06 2001 9 51 Pag 10 230V SPECIFICATIONS ELECTRICAL SPECIFICATION Model Number PSPXT450 230 PSPXT700 230 INPUT Voltage 230 VAC 197 262 VAC Frequency 50 Hz 4Hz 60 Hz 4Hz Amperage maximum 4 0A Phase 12 2W Ground OUTPUT Power rating 450 VA 270 W 700 VA 420 W 1250 VA 750 W Voltage 230 VAC 10 Frequenc 50 Hz 1Hz 60 Hz 1Hz Wave form STEP Line mode 2 105 lt 130 load 3 minutes to fault Overload protection Line mode gt 130 load 7s to fault Battery mode gt 105 lt 120 load 20s to shutdown Battery mode gt 120 load 5s to shutdown Type Valve regulated nonspillable lead acid S x Voltage x 1 x 12V x7 Ah 1 x 12V x 9 Ah 2 x 12V x7Ah ating Approved Battery CSB Panasonic BB Battery and Yuasa Manufacturers Transfer Time 2 6 ms typical Operating Back up time gt 10 minutes Recharge time 8hr up to 90 DIMENSION AND WEIGHTS Dimensions wxhxd mm 80 176 5 233 80 176 5 233 92 238 283 Net Weight Kg 3 5 3 6 6 5 Gros Weight Kg 4 5 4 6 7 9 Operation temperature 0 C to 40 C Storage Temperature 15 C to 40 C Operation humidity 20 to 90 10 PS PXT inglese qxd 6 06 2001 9 51 Pagi all LIMITED WARRANTY Liebert Corporation extends the follo
10. ial interconnection cable for connection to DB9 connector on the rear of the UPS for use with Liebert s SiteNet MultiLink software see user manual for details DO NOT USE FOR OTHER APPLICATIONS Store in safe place if not required at this time This UPS must be earthed at all times during operation Connect only to a mains supply socket outlet with an earth connection A means of disconnection of the mains supply should be within 2 metres of the UPS WARNING Output receptacles on the UPS are electrically live if the UPS is switched ON even if the UPS is not plugged in to a mains supply The On Off button on the UPS does not electrically isolate the internal parts To isolate the UPS switch OFF the UPS first then unplug it from the mains To reduce the risk of electric shock do not remove the cover as it has no user serviceable parts inside Some components are live even when AC power is disconnected For service contact a qualified technician To reduce the risk of fire use the proper rating when replacing the fuse To prevent the risk of fire or electric shock install the UPS in a temperature and humidity controlled room free of conductive contaminants Your total load earth leakage current must not exceed 3 5 milli amperes Most data processing equipment meets this requirement if you use no more than 2 pieces of equipment For further advice contact your dealer The UPS relies on your building wiring overcurrent protection which
11. rom the outlet and contact qualified service personnel if The power cord or plug is damaged a Liquid has been spilled on the UPS a The fuse blows frequently a The UPS does not operate even when user follows the operating instructions CONDITIONS OF USE Your UPS provides conditioned power to connected equipment Maximum load must not exceed that shown on UPS rating label If uncertain consult your distributor or Liebert Placing magnetic storage media on top of the UPS may result in data corruption PS PXT inglese qxd 6 06 2001 9 51 Pagi 4 INTRODUCTION amp SYSTEM DESCRIPTION Congratulations on your choice of the Liebert PowerSure Personal XT Uninterruptible Power System UPS It provides conditioned power to microcomputers and other sensitive electronic equipment MAJOR COMPONENTS PowerSure On Off Status LED Cans Fault LED c AS Blei Akkumulator innerhalb des Gehause INPUT FUSE 250V 5A T Lead acid battery inside the enclosure OUTPUT Liebert FRONT BACK PS PXT inglese qxd 6 06 2001 9 51 Pagi 5 GENERAL INSTALLATION Remove from Box Remove Plug from Units and replace in UPS ill C_J Game 5 Plug Units s into UPS Press ON Button PS PXT inglese qxd 6 06 2001 9 51 Pag 6 NORMAL MODE OPERATION
12. ut limitation use in a manner contrary to the accompanying instructions or applicable codes WARNING Warranty is void if the battery is allowed to discharge below the minimum battery cutoff point To prevent such discharge DO NOT leave the unit power switch ON for more than two 2 days without AC power being supplied to the UPS The battery must be recharged every four 4 to six 6 months when not in use If the UPS fails to conform with the above warranty within the two year warranty period Liebert will repair or replace the UPS at Liebert s option Repairs or replacements are warranted for the remainder of the original warranty period To make a warranty claim purchaser should call a Liebert Representative to obtain a Returned Goods Authorization number and shipping instructions Return transportation costs to Liebert are the responsibility of the Purchaser LIFE SUPPORT APPLICATIONS Due to the diversity of applications and considerations to be applied in each case Liebert does not recommend or knowingly sells its products for such use The responsibility for risk assessment and management in applications where the malfunction or failure of the UPS could be reasonably expected to give rise to a risk of human life shall be the sole responsibility of the purchaser Liebert accepts no liability for consequential harm in such applications 11 PS PXT inglese qxd 6 06 2001 9 51 Pagi 12 Liebert Keeping Business in Business
13. wing LIMITED WARRANTY to the purchaser and to its customer collectively referred to as the Purchaser the enclosed Uninterruptible Power System UPS and components are free from defects in materials and workmanship under normal use service and maintenance FOR A PERIOD OF TWO YEARS FROM THE DATE OF ORIGINAL PURCHASE from Liebert or the Liebert dealer or retailer THE FOREGOING WARRANTY IS THE ONLY WARRANTY GIVEN AND NO OTHER WARANTY IS PROVIDED EXPRESS OR IMPLIED INCLUDING WITHOUT LIMITATION MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE Certain aspects of disclaimers are not applicable to consumer products acquired by individuals and used for personal family or household purposes as distinguished from industrial or other purposes Local laws may not allow limitations on how long an implied warranty lasts so the above limitation may not apply to you This warranty gives you specific legal rights and you may have other rights which vary according to local law Certain repairs or services are the responsibility of the Purchaser and the Purchaser is expected to pay for them This warranty does not extend either to products with removed or altered serial numbers or to any losses or damages due to act of God or source external to the product misuse accident abuse neglect negligence unauthorized modification alteration or repair use beyond rated capacity or improper installation maintenance application or use including witho