Home

Datalogic Gryphon BT100

image

Contents

1. 4 Configure the OM Gryphon BT cradle Refer to the following paragraphs depending on the interface selection code required for your application USB Interface Selection OM Gryphon BT Host yp SIE c A The USB interface is compatible with Windows 98 and later IBM POS for Windows Mac OS 8 0 and later 4690 Operating System DATALOGIC USB START UP As with all USB devices upon connection the Host performs several checks by communicating with the OM Gryphon BT Before the OM Gryphon BT is ready the correct USB driver must be loaded For all systems the correct USB driver for the default USB KBD interface is included in the Host Operating System and will either be loaded automatically or will be suggested by the O S and should therefore be selected from the dialog box the first time only You can now read codes with the associated Gryphon BT reader At this point you can read the USB interface configuration code according to your application Load drivers from the O S if requested When configuring the USB COM interface the relevant files and drivers must be installed from the USB Device Installation software which are available on the CD ROM and can also be downloaded from the web site http www scanning datalogic com The OM Gryphon BT is ready First Start Up Connect OM Gryphon BT to Host Load drivers if requested Select desired USB interface code USB KBD is
2. e the radio connection is signaled by the blue LED through a single blink at regular intervals while if the reader radio is disconnected the LED emits two short blinks at regular intervals e uring the initialization procedure if the radio connection attempt is successful the reader emits four ascending tones e the radio disconnection is signaled by four descending tones STATUS LED INDICATOR Blue LED Meaning 1 blink 2 sec Radio connected 2 blinks 2 sec Radio not connected 1 Blink Good decoding Short blinks Master only Connection re connection attempts For more details and other meanings of the Gryphon BT indicators LED blue spot and beeper refer to the Gryphon BT Reference Manual on the configuration CD ROM DATA TRANSMISSION WITH A BT DEVICE When Gryphon BT is connected with a BT device the transmission of data can be transparent no ACK NACK protocol each character is read and immediately sent to the Host default value Otherwise data transmission can be with flow control with ACK NACK protocol after each reading Gryphon BT waits for an acknowledge that the remote Host received the data before reading and sending the following code RTS CTS handshaking should be set by the Bluetooth COM driver for correct serial communication If not used the RTS line must be forced to the level that doesn t block such communication DATALOGIC INITIAL SETUP Th
3. SERVICES 8 SUPPORT Datalogic Services Warranty Extensions and Maintenance Agreements Authorised Repair Centres CONTACT US E mail form and listing of Datalogic Subsidiaries WARRANTY Datalogic warranties this product against defects in workmanship and materials for a period of 24 months from the date of shipment provided that the product is operated under normal and proper conditions Datalogic has the faculty to repair or replace the product these provisions do nat prolong the original warranty term The warranty does not apply to any product that has been subject to misuse accidental damage unauthorized repair or tampering 27 DATALOGIC PATENTS This product is licensed under the U S patent 6 158 661 This product is covered by one or more of the following patents U S patents 5 992 740 6 305 606 B1 6 517 003 B2 6 631 846 B2 6 712 271 B2 6 808 114 B1 6 817 525 B2 and 6 834 806 B2 European patents 851 378 B1 895 175 B1 962 880 B1 997 760 B1 1 128 315 B1 and 1 164 536 1 Additional patents pending COMPLIANCE This device must be opened by qualified personnel only The batteries must be removed before opening the device FCC COMPLIANCE Modifications or changes to this equipment without the expressed written approval of Datalogic could void the authority to use the equipment This device complies with PART 15 of the FCC Rules Operation is subject to the following two conditio
4. however Datalogic reserves the right to change any specification at any time without prior notice Datalogic is a registered trademark of Datalogic S p A in many countries and the Datalogic logo is a trademark of Datalogic S p A all licensed to Datalogic Scanning Inc All other trademarks and trade names referred to herein are property of their respective owners CONTENTS UPDATES AND LANGUAGE AVAILABILITY eeeeeee eren nnne IV USING GRYPHON BT SERIES READERS s eeeeeereeennenn nennen 1 GUIDE TO SYSTEM START UP eeeeeeseeeeee eene nnne nenne nnns nnne nnns nnn 2 CONNECTING OM GRYPHON 6 6 2 2 nennen nn 3 Changing the Batteries cei scena nace need eder Ced de eb ent 4 GRYPHON BT OPERATION eeeeeeeeeeen nennen nennen nennen nnn nsn nnn nnns 5 Radio Connection su Status LED Indicator nD Data Transmission With a BT Device ccooocoocconccccnnnooooccnnccononoonncnnnnonannnonccnnncnnnns 5 INITIAL SETUP 2 tercer ence 6 Setting Up Gryphon BT with OM Gryphon BT mb USB Interface Selection ananwwaanawanwwwanawan und 5232 Interface Selection certet re Kinana ee eoe eed 10 WEDGE Interface Selection 11 PEN Emulation Interface Selection aa 14 Setting Up Gryphon BT with Bluetooth Device 15
5. max 8 W charging Battery charging red Charge completed green Power yellow max 5 hours 0 to 40 C 32910 104 F 20 to 70 C 4 to 158 F 90 non condensing IP30 RS232 9600 None about 250 g 8 81 oz 208 107 x 55 5 mm 8 1 4 2 x 2 18 in ABS DATALOGIC Electrical Features Supply voltage Power consumption Indicators Time of recharge Environmental Features Working temperature Storage temperature Humidity Protection class Communications Interface Mechanical Features Weight Dimensions Material Electrical Features Supply voltage Power consumption Indicators Time of recharge Environmental Features Working temperature Storage temperature Humidity Protection class Communications Interface Baud Rate Data Bits Stop Bit Parity Mechanical Features Weight Dimensions Material Having a switching regulator inside the OM Gryphon C Gryphon cradles draw the same power regardless of the supply voltage i e as the input voltage increases the current drawn decreases 24 Gryphon BT Cordless Reading Systems READING DIAGRAMS GRYPHON BT100 Reading Zones 10 skew angle EAN13 M 1 CODE 39 13 mm 0 33 mm 1mm 5 mils 13 mils 40 mils 5 10 15 20 25 30 35 40 cm GRYPHON BT200 Reading Zones 10 skew angle 10 0 13 mm 5 mils 5 000839 EAN13M 1 CODE39 0 0 33 mm 0 50 m
6. DATALOGIC GRYPHON BT CORDLESS READING SYSTEMS Quick Reference Guide OO Datalogic Scanning Inc 959 Terry Street Eugene Oregon 97402 Telephone 541 683 5700 Fax 541 345 7140 An Unpublished Work All rights reserved No part of the contents of this documentation or the procedures described therein may be reproduced or transmitted in any form or by any means without prior written permission of Datalogic Scanning Inc or its subsidiaries or affiliates Datalogic or Datalogic Scanning Owners of Datalogic products are hereby granted a non exclusive revocable license to reproduce and transmit this documentation for the purchaser s own internal business purposes Purchaser shall not remove or alter any proprietary notices including copyright notices contained in this documentation and shall ensure that all notices appear on any reproductions of the documentation Should future revisions of this manual be published you can acquire printed versions by contacting your Datalogic representative Electronic versions may either be downloadable from the Datalogic website www scanning datalogic com or provided on appropriate media If you visit our website and would like to make comments or suggestions about this or other Datalogic publications please let us know via the Contact Datalogic page DISCLAIMER Datalogic has taken reasonable measures to provide information in this manual that is complete and accurate
7. code identifier enabled no field adjustment code length not transmitted no header terminator CR character replacement disabled address stamping disabled address delimiter disabled ICL 9600 baud parity even 8 data bits 1 stop bit handshaking RTS always on delay disabled rx timeout 9 9 sec ack nack disabled serial trigger lock disabled DATA FORMAT code identifier enabled no field adjustment code length not transmitted no header terminator CR character replacement disabled address stamping disabled address delimiter disabled 20 Gryphon BT Cordless Reading Systems WEDGE USA keyboard caps lock off caps lock auto recognition enabled num lock unchanged inter character and inter code delays disabled DATA FORMAT code identifier disabled no field adjustment code length not transmitted no header terminator ENTER character replacement disabled address stamping disabled address delimiter disabled PEN EMULATION interpret mode conversion to code 39 disabled output level normal idle level normal minimum output pulse 600 us overflow medium inter block delay disabled DATA FORMAT for BT DEVICE code identifier disabled field adjustment disabled code length tx not transmitted character replacement disabled address stamping disabled address delimiter disabled no header terminator CR LF POWER SAVE maximum scan rate READING PARAMETERS hardware trigger trigg
8. default Load drivers if requested Read test codes OM Gryphon BT is READY Successive start ups will automatically recognize the previously loaded drivers Gryphon BT Cordless Reading Systems USB USB KBD default USB KBD ALT MODE USB KBD APPLE USB COM USB IBM Table Top USB IBM Hand Held When configuring USB COM the relevant files and drivers must be installed from the USB Device Installation software which are available on the CD ROM and can also be downloaded from the web site see http Awww scanning datalogic com DATALOGIC RS232 Interface Selection OM Gryphon BT Host yp 4 h T 1 Read the OM Gryphon BT restore default code Restore OM Gryphon BT Default 2 Read the interface selection code for your application Standard RS232 POS TERMINALS Nixdorf Mode A Fujitsu ICL Mode 10 Gryphon BT Cordless Reading Systems WEDGE Interface Selection Host OM Gryphon BT gt lt 1 Read the OM Gryphon BT restore default code Restore OM Gryphon BT Default 2 Read the interface selection code for your application WEDGE IBM AT or PS 2 PCs IBM XT PC Notebook 11 DATALOGIC IBM SURE1 IBM Terminal 3153 IBM Terminals 31xx 32xx 34xx 37xx To select the interface for these IBM Terminals read the correct key transmission code Select the keyboard type if necessar
9. remote Bluetooth Slave device the reader emits a series of ticks and short blinks of the blue LED The following figure shows an example Gryphon BT Master application Slave PLA Master Gryphon BT reader Barcode Printer Bluetooth device To configure the Gryphon BT as Master follow the given procedure Note for the hexadecimal character selection of step 4 use the Hex Numeric table on the following page 1 Restore Gryphon BT Default 2 Set Gryphon BT as Master 17 DATALOGIC 3 Enter Configuration 4 Set Remote Bluetooth Device Address slave 12 characters in HEX format for the remote Bluetooth device address specified in each Bluetooth device 5 Exit and Save Configuration 6 Request Radio Connection with Slave If the connection is not successful you can attempt a connection manually by double clicking the reader trigger YOUR READER IS NOW CONFIGURED TO READ BARCODES USING THE DEFAULT VALUES 18 Gryphon BT Cordless Reading Systems HEX NUMERIC TABLE 0 DIR 1 2 3 4 DIR 5 6 7 8 9 A III 8 0 D DIR E E 19 DATALOGIC GRYPHON BT DEFAULT CONFIGURATION USB DATA FORMAT code identifier disabled no field adjustment code length not transmitted character
10. replacement disabled address stamping disabled address delimiter disabled USB KEYBOARD USA keyboard inter character and inter code delays disabled USB COM no handshaking delay disabled rx timeout 5 sec ack nack disabled serial trigger lock disabled Default Headers and Terminators for each USB mode USB KBD no header terminator ENTER USB KBD ALT MODE no header terminator CR USB COM no header terminator CR LF USB IBM TABLE TOP not applicable USB IBM HAND HELD not applicable RS232 Standard 9600 baud no parity 8 data bits 1 stop bit no handshaking delay disabled rx timeout 5 sec ack nack disabled serial trigger lock disabled DATA FORMAT code identifier disabled no field adjustment code length not transmitted no header terminator CR LF character replacement disabled address stamping disabled address delimiter disabled Nixdorf Mode A 9600 baud parity odd 8 data bits 1 stop bit handshaking hardware RTS CTS delay disabled rx timeout 9 9 sec ack nack disabled serial trigger lock disabled DATA FORMAT code identifier enabled no field adjustment code length not transmitted no header terminator CR character replacement disabled address stamping disabled address delimiter disabled Fujitsu 9600 baud no parity 8 data bits 1 stop bit no handshaking delay disabled rx timeout 2 sec ack nack disabled serial trigger lock disabled DATA FORMAT
11. C Gun Locator Charging Battery reconditioning button red LED Charge completed green LED Power on Data yellow LED After many recharging cycles NiMh and NiCd batteries may tend to lose their operating autonomy This condition can be overcome by positioning the Gryphon BT onto the OM Gryphon BT cradle or C Gryphon charger and pressing the battery reconditioning button A complete discharge cycle will be performed and then the battery will be recharged This procedure may take several hours On OM Gryphon BT this button also activates the gun locator function see the Gryphon BT Reference Manual for details Changing the Batteries When the battery reconditioning procedure is no longer effective the batteries must be changed To change the batteries of your reader unscrew the battery cover screw replace the old batteries with new ones then insert the cover in the handle and screw it back into place See the following figures Do not incinerate disassemble short terminals or expose to high temperature Risk of fire explosion Use specified charger only Risk of explosion if the battery is replaced by an incorrect type Dispose of the batteries WARNING as required by the relevant laws in force Gryphon BT Cordless Reading Systems GRYPHON BT OPERATION RADIO CONNECTION The blue LED and or the beeper always indicate the reader radio connection status see the table below
12. Setup for Gryphon BT as Slave oococconncnoconnnnccconnnnnconcnnnonccnnnnrnonnnnrccnnnn rr 15 Setup for Gryphon BT as Master 17 GRYPHON BT DEFAULT CONFIGURATION 20 gt 23 READING DIAGRAMS nnns nsn nnn 25 TROUBLESHOOTING 26 SERVICES AND SUPPORT sns anna nn ennu 27 WARRANTY edicere id 27 LJ viz pee TED 28 COMPLIANCE 22ANG BAND AA dee 28 Ee le 28 Radio Compliance cec An denies 29 RETTEN 29 WEEE COMPLIANCE earen 29 29 UPDATES AND LANGUAGE AVAILABILITY UK US The latest drivers and documentation updates for this product are available on Internet Log on to www scanning datalogic com Su Internet sono disponibili le versioni aggiornate di driver e documentazione di questo prodotto Questo manuale 6 disponibile anche nella versione italiana Collegarsi a www scanning datalogic com F Les versions mises jour de drivers et documentation de ce produit sont disponibles sur Internet Ce manuel est aussi disponible en version francaise Cliquez sur www scanning datalogic com D Im Internet finden Sie die aktuellsten Versionen der Treiber und Dokumentation f r dieses Produkt Die deutschsprachige Version dieses Handbuches ist auch verf gbar Adresse www scanning datalogic com E En Internet est n disponibles las versiones actualizadas de los drivers y documentaci n de este producto Tambi n est disponible la versi n
13. al necessity of a user license Refer to the web site http europa eu int comm enterprise rtte spectr htm for further information CEO POWER SUPPLY For OM Gryphon BT and C Gryphon This device is intended to be supplied by a UL Listed or CSA Certified Power Unit marked Class 2 or LPS output rated 9 28 V minimum 0 9 A which supplies power directly to the unit via the jack connector WEEE COMPLIANCE 8 Ll LED CLASS 2105 i o HEHE O8S SAHI THH det GE EE Him E D iiir g Ces a HRE Os E en Bi TO EN60825 1 2001 C Bis 29 Datalogic Scanning Inc 959 Terry Street Eugene OR 97402 07 dichiara che declares that the d clare que le bescheinigt daB das Ger t declare que el Gryphon BT100 CSR CORDLESS SYSTEM Gryphon BT200 CSR CORDLESS SYSTEM e tutti i suoi modelli and all its models et tous ses mod les und seine Modelle y todos sus modelos sono conformi alle Direttive del Consiglio Europeo sottoelencate are in conformity with the requirements of the European Council Directives listed below sont conforme aux sp cifications des Directives de l Union Europ enne ci dessous der nachstehend angef hrten Direktiven des Europ ischen Rats cumple con los requisitos de las Directivas del Consejo Europeo seg n la lista siguiente 1999 5 EEC R amp TTE Questa dichiarazione basata sulla conformit dei prodotti alle norme seguenti This declaration is based up
14. e packing user friendly name Gryphon BTx00 auto connection enabled auto reconnection enabled 22 Gryphon BT Cordless Reading Systems TECHNICAL FEATURES Gryphon BT Electrical Features Battery Type 2 AA NiMh batteries 1 2 V 1850 mAh or 2100 mAh Time of recharge typ continuous reading Max scan rate Indicators Sensor CCD solid state 3648 pixels Illuminator LED array Wavelength 630 670 nm Max LED Output Power 0 33 mW LED Safety Class Class 1 EN 60825 1 Reading field see reading diagrams on page 25 Max resolution PCS minimum eading Pitch angle eading Skew angle eading Tilt angle Bluetooth version Profiles supported Class Working Temperature 0 to 40 C 32 to 104 F Storage Temperature SU Ng o without battery 20 to 70 C 4 to 158 F Humidity Drop resistance Ambient light immunity 100000 lux sunlight 4000 lux artificial light Protection class Weight with batteries Dimensions Material It is possible to employ also NiCd or non chargeable Alkaline AA batteries 23 OM Gryphon BT 9 28 Vdc max 8 W charging Battery charging red Charge completed green Power Data yellow max 5 hours 0 to 40 C 32 to 104 F 20 to 70 C 4 to 158 F 90 non condensing IP30 USB RS232 Wedge Pen emulation about 250 g 8 81 oz 208 107 55 5 mm 8 1 4 2 2 18 in ABS C Gryphon 9 28 Vdc
15. e Gryphon BT Reference Manual or power off the Bluetooth Slave device A second gun has erroneously remained connected to the cradle Unbind the second gun The OM Gryphon BT has lost the Bind address for example after a software upgrade and therefore refuses any connection Repeat the Bind procedure The beeper and LED signal radio disconnection from the remote Bluetooth device The requested radio connection by Gryphon BT Master does not activate The remote Bluetooth device recognizes Gryphon BT but cannot connect to it The radio range seems reduced A Gryphon BT Master fails to make an automatic connection A Gryphon BT Master remains connected to a Slave device A Gryphon BT gun continuously connects and disconnects from its OM Gryphon BT cradle 26 Gryphon BT Cordless Reading Systems Unbind Power OFF SERVICES AND SUPPORT Datalogic provides several services as well as technical support through its website Log on to www scanning datalogic com and click on the links indicated for further information including PRODUCTS Search through the links to arrive at your product page where you can download specific Manuals and Software amp Utilities including Datalogic Aladdin a multi platform utility program which allows device configuration using a PC It provides RS232 USB COM interface configuration as well as configuration barcode printing
16. en espa ol de este manual Direcci n Internet www scanning datalogic com Gryphon BT Cordless Reading Systems USING GRYPHON BT SERIES READERS The Gryphon BT Gryphon Bluetooth reader is a CCD wireless barcode scanner which is part of one of the Cordless Reading Systems described below CSR Kit When paired with the OM Gryphon BT cradle Gryphon BT builds a Cordless Reading System for the collection decoding and transmission of barcoded data OM GryphonTM BT can be connected to a Host PC through a USB RS232 Wedge or Pen emulation cable The OM Gryphon BT cradle also serves as battery charger for Gryphon BT CS Kit Gryphon BT can also be used together with a Bluetooth compatible remote device to build a Cordless Reading System The Bluetoothe compatible remote device can be a PC PDA printer etc with a built in Bluetoothe device or with external Bluetoothe adapter i e Bluetoothe dongle In this case the C Gryphon cradle serves as battery charger for Gryphon BT With this Quick Reference Manual you can set up your Gryphon BT reader and begin using it with its default values For configuration details refer to the Gryphon BT Reference Manual on the configuration CD ROM Gryphon BT readers automatically scan barcodes at a distance Simply aim the reader and pull the trigger Code scanning is performed along the center of the light bar emitted from the reading window This bar must cov
17. er active level no timeout Flash On 1 sec Flash Off 0 6 sec one read per cycle safety time 0 5 sec beeper intensity high tone 2 beeper type monotone beeper length short good read spot duration medium DECODING PARAMETERS ink spread enabled overflow control enabled interdigit control enabled Puzzle Solver disabled decoding safety one read 21 DATALOGIC CODE SELECTION enabled codes BT200 Code PDF417 EAN 8 EAN 13 UPC A UPC E without ADD ON check digit transmitted no conversions Interleaved 2 5 check digit control and transmission variable length code BT100 4 h BT200 99 characters Standard Code 39 no check digit control variable length code 1 99 characters Code 128 variable length code 1 99 characters disabled codes BT100 EAN 128 ISBT128 Code 93 Codabar pharmaceutical codes MSI Plessey Telepen Delta IBM Code 11 Code 16K Code 49 RSS family BT200 EAN 128 ISBT128 Code 93 Codabar pharmaceutical codes RSS family ADVANCED FORMATTING PARAMETERS concatenation disabled no advanced formats defined Zebra printer formatting disabled RADIO PARAMETERS ALL CONFIGURATIONS radio protocol timeout 3 seconds transmission retry none power off timeout 4 hours beeper control for radio response good decode and good reception GRYPHON BT WITH OM GRYPHON BT encryption disabled batch mode disabled GRYPHON BT WITH BT DEVICE no ACK NACK protocol nor fram
18. er the entire code READING ANGLE Successful scanning is performed by tilting the reader with respect to the barcode to avoid direct reflections which impair the reading performance see the figure below Successful reading is signaled by an audible tone plus a good read blue spot Good read LED Good read spot Not Advised DATALOGIC GUIDE TO SYSTEM START UP CSR KIT Connect the OM Gryphon BT cradle to a power supply and charge the Gryphon BT battery as described in this Quick Reference manual A full charge takes less than 5 hours with NiMh batteries Connect the OM Gryphon BT cradle to the Host PC and configure the reader as described in this Quick Reference manual under Setting Up Gryphon BT with OM Gryphon BT 1 CS KIT Connect the C Gryphon charger to a power supply and charge the Gryphon BT battery as described in this Quick Reference manual A full charge takes less than 5 hours with NiMh batteries Have a compatible remote Bluetooth device with built in Bluetooth radio or an external Bluetooth adapter ready to work See your Bluetooth compatible device documentation Configure the reader as described in this Quick Reference manual under Setting Up Gryphon BT with Bluetooth Device 1 CONNECTING OM GRYPHON BT C GRYPHON To connect the OM Gryphon BT or C Gryphon cradle Connect the OM Gryphon BT to the appropriate interface cable which must be simply pl
19. is procedure allows setting up the reader to operate with the default settings Two different procedures are available according to the type of application you are working with CSR Kit Gryphon BT paired to the OM Gryphon BT follow the procedures indicated in the paragraph below CS Kit GryphonTM BT communicating with a Bluetooth device follow the procedures indicated in the paragraph starting on page 15 Whenever you need to change the default values refer to the GryphonTM BT Reference Manual SETTING UP GRYPHON BT WITH OM GRYPHON BT Follow the given procedure to set communication between Gryphon BT and OM Gryphon BT Read the restore default parameters code below Restore Gryphon BT Default 2 Read the Bind code to pair the Gryphon BT to the OM Gryphon BT cradle The reader is dedicated to the cradle The cradle will refuse connection to any previously bound reader It is however advised to unbind any previously bound reader Bind The blue LED on the Gryphon BT will blink the reader is ready to be positioned onto the cradle 3 Firmly position the reader onto the OM Gryphon BT cradle within 4 seconds a beep will be emitted signaling that the OM Gryphon BT cradle has been paired to the Gryphon BT Gryphon BT Cordless Reading Systems Blue LED Wait for a series of beeps three sequences of tones separated by a pause indicating Bluetooth connection
20. m 5 mils 13 mils 20 mils 5 10 0 5 10 15 20 25 30 35 cm PDF417 codes Reading Zones 10 skew angle 8 T T T PDF417 Aspect Ratio 3 1 6 4 2 0 17 mm 0 38 mm 6 6mils 15mils 0 2 E 6 0 25 mm 10mils 8 1 0 2 4 6 8 10 12 14 16 cm 25 DATALOGIC TROUBLESHOOTING Problem____ Solution The distance between the remote device and GryphonTM BT may be too far or there may be obstacles to radio transmission between them Reconnect Reduce the distance between the devices Check that Gryphon BT is powered batteries are charged that the radio protocol software version is compatible with Gryphon BT that there is not already another BT 6 connected using the same SPP profile Insert the remote device address again to Gryphon BT Check the Gryphon M BT configuration using the Transmit configuration command via C Gryphon cradle Check that there are no limits set to the connection such as a password Check that the radio protocol software version is compatible with Gryphon BT Check that there are no obstacles to radio transmission between the devices Double click the trigger to force an immediate retry of the radio connection or read the Request Radio Connection code in the Gryphon BT Reference Manual Read the Request Radio Disconnection code in th
21. ngland Telephone 44 0 1923 809500 Fax 44 0 1923 809 505 Australia Datalogic Scanning Pty Ltd North Ryde Australia Telephone 61 2 9870 3200 Fax 61 2 9878 8688 France and Benelux Datalogic Scanning Sarl LES ULIS Cedex France Telephone 33 01 64 86 71 00 Fax 33 01 64 46 72 44 Germany Datalogic Scanning GmbH Darmstadt Germany Telephone 49 0 61 51 93 58 0 Fax 49 0 61 51 93 58 58 Italy Datalogic Scanning SpA Vimercate MI Italy Telephone 39 0 39 62903 1 Fax 39 0 39 6859496 SDATALOGIC www scanning datalogic com Datalogic Scanning Inc 959 Terry Street Eugene OR 97402 Telephone 541 683 5700 Fax 541 345 7140 2007 Datalogic Scanning Inc 820001691 Rev B 09 07
22. ns 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference which may cause undesired operation OM Gryphon BT This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help 28 Gryphon BT Cordless Reading Systems RADIO COMPLIANCE Contact the competent authority responsible for the management of radio frequency devices of your country to verify the eventu
23. on compliance of the products to the following standards Cette d claration repose sur la conformit des produits aux normes suivantes Diese Erkl rung basiert darauf daB das Produkt den folgenden Normen entspricht Esta declaraci n se basa en el cumplimiento de los productos con la siguientes normas ETSI EN 301 489 17 v1 2 1 ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM AUGUST 2002 MATTERS ERM ELECTROMAGNETIC COMPATIBILITY EMC STANDARD FOR RADIO EQUIPMENT AND SERVICES PART 17 SPECIFIC CONDITIONS FOR 2 4GHZ WIDEBAND TRANSMISSION SYSTEMS AND 5GHZ HIGH PERFORMANCE RLAN EQUIPMENT ETSI EN 300 328 v1 6 1 ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM NOVEMBER 2004 MATTERS ERM WIDEBAND TRANSMISSION SYSTEMS DATA TRANSMISSION EQUIPMENT OPERATING IN THE 2 4GHZ ISM BAND AND USING WIDE BAND MODULATION TECHNIQUES HARMONIZED EN COVERING ESSENTIAL REQUIREMENTS UNDER ARTICLE 3 2 OF THE R amp TTE DIRECTIVE EN 60950 1 DECEMBER 2001 INFORMATION TECHNOLOGY EQUIPMENT SAFETY PART 1 GENERAL REQUIREMENTS March 1st 2007 Japan Datalogic Scanning KK Shinagawa Tokyo Japan Telephone 81 0 3 3491 6761 Fax 81 0 3 3491 6656 Latin America Datalogic Scanning Inc Miami Florida USA Telephone 305 591 3222 Fax 305 591 3007 Spain and Portugal Datalogic Scanning Sarl Sucursal en Espa a Madrid Spain Telephone 34 91 746 28 60 Fax 34 91 742 35 33 United Kingdom Datalogic Scanning LTD Watford E
24. r communication however some radio parameters can be set to increase system performance and data transmission security see the Gryphon BT Reference Manual on the configuration CD ROM At startup the reader can only wait for the Master to initialize the radio communication The following is a general procedure recommended for Gryphon BT Slave applications 1 Power up the remote Bluetooth Master device example Laptop or PC 2 After charging the batteries power up the Gryphon BT reader within radio range 10 meters Any modifications to the radio configuration should be made at this time before the radio connection takes place 3 From the remote Bluetooth Master device execute the Discovery procedure according to the procedure given in the documentation of the Bluetooth Master device to recognize the Gryphon BT reader s within radio range 4 Check that Gryphon BTx00 is shown among the discovered devices 5 Request to open an SPP connection with Gryphon BT making sure to disable any required PIN and or pairing parameters Gryphon BT is always discoverable and connectable without any required PIN If the PIN of the Bluetooth Master device cannot be disabled use the PIN 1234 The Gryphon BT Slave will emit four ascending tones indicating radio connection NOTE After the Gryphon BT reader indicates radio connection see also the Status LED Indicator Table on page 5 you can start
25. sending barcodes The following figure shows an example Gryphon BT Slave application 15 DATALOGIC Laptop Bluetooth device Slave Master br BT readers 6 Slave If the Master Bluetooth device can support a piconet the communication can be established with up to 7 seven Slave readers at the same time To configure the Gryphon BT as Slave follow the given procedure 1 Restore Gryphon BT Default 2 Set Gryphon BT as Slave YOUR READER IS NOW READY TO BE DISCOVERED CONNECTED VIA RADIO BY A BLUETOOTH MASTER DEVICE AND READ BARCODES 16 Gryphon BT Cordless Reading Systems Setup for Gryphon BT as Master A Gryphon BT is Master when the remote Bluetooth device is Slave i e with a Bluetooth barcode printer Once set as Master a Gryphon BT reader must be configured with the address of the Slave device to which it wants to communicate As Master it can initiate a connection with only one Slave device By default at startup the reader initializes the communication with the Slave If the connection is successful the reader can send barcodes to the Slave device If the connection is not successful you can attempt a connection manually by double clicking the reader trigger Radio connections can also be managed manually as described in the GryphonTM BT Reference Manual on the configuration CD ROM During the request of radio connection or disconnection with a
26. ugged into the Host connector on the base of the cradle C Gryphon can be connected using RS232 only for optional Gryphon BT serial configuration or software upgrade Connect the cradle to an external power supply see the figure below Host Interface Cable Power Supply Bottom View 1 Gryphon BT Cordless Reading Systems To disconnect the Host Interface cable insert a paper clip or other similar object into the hole corresponding to the Host connector on the body of the cradle Push down on the clip while unplugging the cable Refer to the following figure Disconnecting the Cable CHARGING THE BATTERIES By placing the reader onto the OM Gryphon BT cradle or C Gryphon battery charger it is possible to charge the Gryphon BT batteries Make sure the charging LED goes on The LEDs positioned on the cradle signal the charge status as described in the following table LED STATUS Yellow On OM Gryphon BT C Gryphon is powered Yellow Blinking OM Gryphon BT receives data and commands from the Host or the reader Yellow Blinking C Gryphon receives commands from the Host Red On the battery charge is in progress Red Blinking the battery reconditioning is in progress Charge P completed Green On the battery is completely charged Power on Data Wi SEN Red and Green Blinking together the reader is not ER correctly placed onto the cradle or charger DATALOGI
27. y default advanced keyboard KEY TRANSMISSION MODE make only keyboard make break keyboard KEYBOARD TYPE advanced keyboard typewriter keyboard ALT MODE The following interface selection allows barcodes sent to the PC to be interpreted correctly independently from the Keyboard Nationality used You do not need to make a Keyboard Nationality selection default Num Lock Unchanged Make sure the Num Lock key on your keyboard is ON 12 Gryphon BT Cordless Reading Systems IBM AT ALT mode PC Notebook ALT mode WYSE TERMINALS ANSI Keyboard PC Keyboard ASCII Keyboard VT220 style Keyboard DIGITAL TERMINALS VT2xx VT3xx VT4xx APPLE APPLE ADB Bus 13 DATALOGIC PEN Emulation Interface Selection 1 Read the OM Gryphon BT restore default code Restore OM Gryphon BT Default 2 Read the interface selection code for your application PEN Pen Emulation 14 Gryphon BT Cordless Reading Systems SETTING UP GRYPHON BT WITH BLUETOOTH DEVICE Follow one of the following two procedures to set up Gryphon BT as Slave or as Master according to your application Setup for Gryphon BT as Slave A Gryphon BT is Slave when it sends barcodes to a Master remote Bluetooth device such as a PC Laptop PDA etc which has initialized the communication Once set as Slave a Gryphon BT reader requires no particular configuration fo

Download Pdf Manuals

image

Related Search

Related Contents

Presentación    Canon C5235A Product Brochure  User`s Manual - INHECO Industrial Heating & Cooling GmbH  Extron electronic Extron Electronics Speaker SPA 12 AAP User's Manual    1 Indicaciones de seguridad 2 Estructura del mecanismo  Linee Guida Fitodepurazione ARPAT  

Copyright © All rights reserved.