Home
TELULAR SX4E PHONECELL WITH THE 8210 SPEECH MODEM
Contents
1. gt gt gt GSM TDMA PCS AMPS ANALOG Transmit Power gt Maximum 600mW Operating Voltage gt 12VDC 11 5 to 26 VDC Environment gt gt gt Operating temperature range 10C to 50C Storage Temperature Range 25C to 65C Humidity 5 to 95 LED Indicators gt gt gt Power Status Cellular Status FWT Status Connectors gt RJ 45 interface jack for voice Accepts RJ 11 phone line connector 3 2 1 8210 Speech Modem Features gt gt gt S IT O N 21300 RIDGETOP CIRCLE STERLING VA 20166 WWW SUTRON COM 703 406 2800 703 406 2801 FAX SALES SUTRON COM Provides voice report of sensor values DTMF Dual Tone Multi Frequency Decode Speech menu options using DTMF signals TELULAR PHONECELL WITH THE 8210 SPEECH MODEM 4 gt 40C to 85C extended operating temperature 3 2 1 1 Specifications gt gt Operating Temperature 40 C to 60 C Electronics Protected to 3000 Volt peak 500 Joule transient phone line surges from tip to ring tip to ground and ring to ground Low power standby mode Receiver sensitivity 45dBm Receiver dynamic range 36dBm 9dBm to 45dBm Standard Interface Telephone 2 wire to RJ 11 modular jack Mode Capability Full duplex over public switched telephone network PSTN Bell 212A 1200 pbs and Bell 103 300 bps CCITT V 22 1200 bps and V 21 300 bps Answer Mode Ring detect Auto baud rate detect
2. TELULAR SX4E PHONECELL WITH THE 8210 SPEECH MODEM APPLICATION NOTE September 2004 Integrated Systems Division The Sutron Corporation 21300 Ridgetop Circle Sterling VA 20166 Copyright 2004 Sutron Corporation 5 T O N 21300 RIDGETOP CIRCLE STERLING VA 20166 WWW SUTRON COM LJ l 703 406 2800 703 406 2801 FAX SALES SUTRON COM TELULAR PHONECELL WITH THE 8210 SPEECH MODEM i TABLE OF CONTENTS 1 OVervieW ssssssesseessessesssesssessesscesseesesssesssesseossesseestessesssesseossesseeseesseeseeoseossesseeseessee 1 2 Equipment and OptiOnNS s esssessseesscessecsseesseesseeesssessseosecsseeesssesssesssessseesseesss 2 3 Equipment Connections and Specifications s ssssssssseessssessssessssesesseess 2 3 1 Equipment SpecificationS sesssessessesssssessseseessereeeeserseresreeneeessensensensssssn sse ssse set ssetsttreeeeerrereerrereereeeeseess 3 3 1 1 CELLULAR MODEM FEATURES uscssssssssssssssssssssssssnssssssssnsssnsssnsssunsssnessnsssasessnesssassaeeestn 3 3 2 1 8210 Speech Modem Features acnsstiacicanciantaaiiaini an desdenndonauieuiommunanan 3 4 Cellular Modem Activation cccsssssssessssscsesscsecsssessesesssssssessssscnsseesseneaeees 5 5 Speech Modem S tUPencanacnsccminrnnsnnnaannnnnn 6 6 8210 Data Logger with Speech Modem SetUup sssseessssessssessssesssseess 7 6 1 Speech Modem Menu SetUP cccsssssesssssssecsesseesssssscssecesscsncssecsscssecsuscsscsuecsscessssucessceecsseceaccsncescsncesses
3. band assignment Band Order Digits EIA TIA 136 1 System A 800 MHz 2 System B 800 MHz 3 Band A 1900 MHz 4 Band B 1900 MHz 5 Band C 1900 MHz 6 Band D 1900 MHz 7 Band E 1900 MHz 8 Band F 1900 MHZ If the band order values are not in the range of 1 to 8 or there are less than 1 or more than 8 digits the entry is considered invalid The factory default is3 4125678 7 Hang up the phone The flashing LED indicator will become solid GREEN Phone Number Setup is complete 5 Speech Modem Setup The 8210 3014 1A is shipped from the factory with the Speech Modem installed and the 8210 configured as a Speech Modem unit Users can purchase Speech Modem modules to be added in the field The part number for this module is 8200 3000 3 and includes gt Speech Modem Module gt Interface Cable gt RJ 11 receptacle with 6 inch phone cable gt Mounting hardware screws and washers The typical installation would place the Speech Modem module in the upper option location of the 8210 The interface cable would be connected to the cable header labeled J5 nearest the edge of the 8210 Microprocessor module When connected to the J5 header the S1 DIP switches on the 8210 Microprocessor board need to be set as gt SW3 CLOSED gt SW4 OPEN Switch settings the 8210 are described in Chapter 11 of the 8270 Operations Manual IT O N 21300 RIDGETOP CIRCLE STERLING VA 20166 WWW SUTRON COM 703 406 2800 703 406 280
4. provide a typical programming setup Consult the Phonecell SX4e User Manual for the detailed programming instructions Except for the Mobile Identification Number MIN discussed below the factory defaults will work in most cases Be certain to review the programming steps given below with your service provider or have your service provider program the Phonecell The exact programming may vary from model to model refer to Telular Phonecell User Manual sent with the unit for final instructions Before you begin programming connect the antenna plug in the power and connect a tone dial DTMF telephone 1 Pick up the POTS telephone handset and listen for a tone either a steady dial tone or a beeping no service tone 2 Press 0 12344321 The tone will change to a different steady Programming tone and the bottom LED indicator on the Phonecell will blink alternately RED and GREEN to indicate that you re in programming mode You now have two minutes to start the programming steps 3 Press 1 lt MIN gt This key sequence is used to enter your 10 digit telephone number Mobile Identification Number or MIN If you enter the number incorrectly you ll hear 3 short tones followed by the programming tone If correct you ll hear the programming tone again If the MIN phone number value is not 10 digits it is considered invalid and the FWT will not update or store this value the currently stored value will remain Note With
5. 1 FAX SALES SUTRON COM TELULAR PHONECELL WITH THE 8210 SPEECH MODEM 7 6 8210 Data Logger with Speech Modem Setup This section presents the setup steps that enable the 8210 to use the Speech Modem An example setup of one sensor input configured to use the Speech Modem is included Complete details for setting up the Speech Modem are presented in the Modem Setup section of Chapter 4 of the 8210 Operators Manual 6 1 SPEECH MODEM MENU SETUP The 8210 unit requires the following minimum setup to use the Speech Modem gt Configure the Speech Modem Menu gt Configure a sensor in the ALARMS Menu The Speech Modem will also operate in the data mode when used with the Phonecell unit and AMPS service is available If data access is planned it is highly recommended to do the following additional setup steps gt Seta phone password in the Speech Modem Menu gt Set the Enter Key Required mode to ON in the EEROM Menu Failure to do this last step can lead to loss of the 8210 setup configuration due to a noisy or poor quality phone connect S IT O N 21300 RIDGETOP CIRCLE STERLING VA 20166 WWW SUTRON COM 703 406 2800 703 406 2801 FAX SALES SUTRON COM TELULAR PHONECELL WITH THE 8210 SPEECH MODEM 8 6 1 1 Configuring the Speech Modem Menu The 8210 Main Menu is displayed below Enter M to go to the Speech Modem Setup Menu SUTRON Corp 82160A SR amp 8 Peer to Peer RIU Software MAIN MENU Unit Name PHONECEL Set Date 6
6. 68 1 Antenna YAGI 800MHz 6db w 20ft RF cable 8111 1168 2 Antenna ONMI Dual Band 800 1900 MHz Xdb w 20ft RF cable 8111 1168 3 Antenna YAGI 1900MHz 6db w 20ft RF cable Each includes a coaxial surge protector and 3ft jumper cable to interface from the protector to the SX4e FWT 3 Equipment Connections and Specifications The equipment configuration consists of an 8210 3014 1A Data Logger with Speech Modem option and a SX4e cellular FWT The cellular modem transceiver will be connected to the 8210 Speech Modem using an RJ 11 connection The cellular modem has an RJ 45 receptacle connect a cable from this port to the RJ 11 receptacle of the Sutron RJ 11 module that comes with the 8210 Speech Modem This RJ 11 module connects to the Phone T and R inputs in the 8210 terminal block Ru 11 Connection Figure 1 8210 connects to the SX4e FWT via a standard RJ 11 phone cable S IT O N 21300 RIDGETOP CIRCLE STERLING VA 20166 WWW SUTRON COM 703 406 2800 703 406 2801 FAX SALES SUTRON COM TELULAR PHONECELL WITH THE 8210 SPEECH MODEM 3 1 Equipment Specifications 3 1 1 CELLULAR MODEM FEATURES Exceptional voice quality with echo cancellation and digital voice data privacy DTMF and pulse dial capability External linear power supply Built in signal strength indication and self monitoring capabilities for user diagnostics Easily programmed using ordinary telephone 3 1 1 1 Specifications Air Interface Standard gt
7. 9 09 2004 Set Time 17 37 58 Recording Status ON Clear Alarm NORMAL View Sensor Data System Setup Options Upload Download Data EEROM Setup Options Protocol Setup Options Speech Modem Setup GOES Radio Setup Inspect System Application Menu AK25 Alarms Setup Menu Exit ae jami ee eee ne ee co vi ge Figure 2 8210 Main Menu The Speech Modem Menu is shown below A minimum setup would include setting gt the Answer Mode Voice Voice amp Data Data amp Voice gt the number of rings before answering default 1 gt Dial In message Modem Setup Menu Dial Out Enable OFF Answer Hode VOICE amp DATA Number of Rings 1 Phone Password A Dial In Message Liv Dial Out Message Phone 1 Phone 2 Phone 3 Redial Delay 66 16 06 Choose _ D A N P I 0 1 2 3 R Figure 3 Speech Modem Menu S iT O N 21300 RIDGETOP CIRCLE STERLING VA 20166 WWW SUTRON COM 703 406 2800 703 406 2801 FAX SALES SUTRON COM TELULAR PHONECELL WITH THE 8210 SPEECH MODEM 9 The Dial In message shown above is one of the canned reports that will speak the name and value of the last measured value of each sensor enabled for current data see Section 6 2 below Users can create a message using a vocabulary string An example shown below uses a Speech Modem string to speak the following message Welcome to the Sutron 82 182 2 1173 170 82 Speech Mode
8. L Low Limit 6 600 R ROC Level 6 600 B DeadBand 0 606 Alarm Phrases P Prefix Name 67 S Suffix Units 177 Figure 5 Alarm Sensor Option Menu The figure above shows that the sensor named Battery has Alarm Options Enable ON with the Alarm Phases set to 67 battery and 177 volts These settings will cause the Liv report to state Battery is 12 52 volts Other settings in the Alarm Sensor Option menu can be used to set high low or ROC rate of change alarms These settings could be used to have the Speech Modem dial out to up to three phone numbers and announce alarm conditions with current sensor values Complete details for using the 8210 Alarm Sensor Option are presented in the System Setup Alarm Options section of Chapter 4 of the 8210 Operators Manual 5S IT O N 21300 RIDGETOP CIRCLE STERLING VA 20166 WWW SUTRON COM 703 406 2800 703 406 2801 FAX SALES SUTRON COM TELULAR PHONECELL WITH THE 8210 SPEECH MODEM 11 7 Troubleshooting Possible Problem Checkpoints Solutions Check cell phone coverage in the area The modem answers but the voice is of The cell phone has 3 LEDS they should all poor quality noisy be green The modem does not pick up you obtain a dead signal Check if the cell modem has 12V Check external battery voltage should be around 12VDC can obtain voice messages from the Contact local cellular provider to see if this modem but no da
9. dial in and obtain real time readings via voice reports Voice reports of alarm conditions defined by the user can be transmitted to up to three different phone numbers by the 8210 Speech Modem dialing out using the SX4e Phonecell FWT The following sections present gt The required equipment and options gt Equipment cable connections and equipment specifications gt Instructions for setting up cellular service and the SX4e FWT gt Instructions for setting up the 8210 Speech Modem Complete instructions for programming the 8210 can be found in the 8210 Users Manual A copy this manual is available at www sutron com DownloadsUpdates 8200_8210Manuals ZIP S IT O N 21300 RIDGETOP CIRCLE STERLING VA 20166 WWW SUTRON COM 703 406 2800 703 406 2801 FAX SALES SUTRON COM TELULAR PHONECELL WITH THE 8210 SPEECH MODEM 2 2 Equipment and Options The application requires the following equipment Part Number Description 1 8210 3014 1A 8210 Data Logger with Speech Modem 2 8111 7000 1 Phonecell SX4e FWT with RJ 11 serial cables battery power cable PHONECELL is a register trade mark of the Telular Corporation The Telular SX4e is supply with an eight 8 inch ONMI antenna intended for interior mounting The antenna input connection of the SX4e is a TNC female connection This antenna is suited for use in areas with strong cellular service signal The following antenna options are available 8111 11
10. ion 2225 Hz Answerback Tone 30 second timeout if baud rate training sequence not complete On Hook Off Hook On hook call termination after autoanswer or auto dial timeout With Call Termination 30 seconds programmable of data inactivity System reset Power up initialization Applicable Standards Phone Line Interface meets or exceeds the following standards o U S Federal Communications o Commission FCC Rules and o Regulations Part 68 o Canadian Department of o Communications Standard CS 03 o Electronic Industries Assoc EIA Standard RS 496 S IT O N 21300 RIDGETOP CIRCLE STERLING VA 20166 WWW SUTRON COM 703 406 2800 703 406 2801 FAX SALES SUTRON COM TELULAR PHONECELL WITH THE 8210 SPEECH MODEM 5 4 Cellular Modem Activation Selection of a cellular service provider involves several considerations including signal strength at the remote site system type TDMA PCS AMPS and service plan cost Most established services started with AMPS and are required to maintain this service Digital data service may be available and may be at a lower cost Consult your service providers in the area of the station to determine the best selection Once a service provider has been selected and service has been initiated the SX4e needs to be programmed for the system The SX4e is programmed with an ordinary tone dial DTMF telephone which is sometimes referred to as POTS Plain Old Telephone Service phone The following steps
11. m Henu Dial Out Enable OFF Answer Mode VOICE amp DATA Number of Rings 1 Phone Password Dial In Message 18 2 173 170 82 10n34 Dial Out Message Phone 1 Phone 2 Phone 3 Redial Delay 66 16 66 Choose DialIn 182 2 173 170 82 10n34 12 r34u34 fe ee Figure 4 Example Speech Modem Vocabulary String The 8210 can be setup to Dial Out and make voice reports of alarm conditions This would be enabled by setting the Dial Out Enable to ON at least one phone number and establishing a Dial out Message string Complete details for using the 8210 vocabulary are presented in the Modem Setup section of Chapter 4 of the 8210 Operators Manual 5S IT O N 21300 RIDGETOP CIRCLE STERLING VA 20166 WWW SUTRON COM 703 406 2800 703 406 2801 FAX SALES SUTRON COM TELULAR PHONECELL WITH THE 8210 SPEECH MODEM 10 6 2 SAMPLE SENSOR SETUP The last step in this example setup shows how a sensor is set to enable Current Data to be included in the canned Liv report This is done using the Alarm Sensor Options Menu This Menu is accessed from the System Setup Menu ALARM SENSOR OPTIONS J Choose U p Dlown E G C T 1 2 3 H L R B CP 1 Active Sensors Alarm Options gt Battery E Enable ON BARO G Groups 6608 C Control OFF T Trend OFF 1 High Alarm OFF 2 Low Alarm OFF 3 ROC Alarm OFF Alarm Limits H High Limit 6 600
12. ses 7 6 2 Sampl Sensor SOU wicieisesscccssitsarstssperenterteedsiveansnstenreassinntrintadeatinenamnianaiannanats 10 Js MOUDlesSROOtNO sa s crcseeceas acer anieininenecaneaneaanets 11 5 IT O N 21300 RIDGETOP CIRCLE STERLING VA 20166 WWW SUTRON COM 703 406 2800 703 406 2801 FAX SALES SUTRON COM TELULAR PHONECELL WITH THE 8210 SPEECH MODEM 1 1 Overview The Telular PhoneCell SX4e is a tri mode TDMA PCS AMPS cellular modem capable of supporting Voice FAX and Data operation Voice operation is supported in all modes This makes the Telular PhoneCell SX4e best suited for applications requiring voice reports The Telular PhoneCell SX4e is a fixed wireless terminal FWT These FWT devices are based on Telular s proprietary RJ 11 to cellular interface technologies This allows connection to the Sutron 8210 Speech Modem using a standard RJ 11 cable connection Data operations with the Phonecell are dependent on several factors including your local cellular service provider Because most TDMA and PCS networks do not support digital fax and data services AMPS 800 MHz networks or AMPS 800 MHz channels on TDMA 800 MHz networks are used for fax and data services Contact your local cellular dealer or service provider to determine the availability of an AMPS analog network Other cellular products are best suited for data only applications The Sutron 8210 Speech Modem will allow voice communication with the 8210 Data Loggers User s may
13. ta feature is available S IT O N 21300 RIDGETOP CIRCLE STERLING VA 20166 WWW SUTRON COM 703 406 2800 703 406 2801 FAX SALES SUTRON COM
14. the instigation of phone number portability user phone number may be different from the MIN Make certain the service provider gives you both the user phone number and the MIN 4 Press 5 lt SID gt This key sequence is used to enter the 1 to 5 digit System Identifier or SID This information identifies your cellular service company If you enter the SID incorrectly you ll hear three short tones followed by the programming tone if correct you ll hear the programming tone again If the SID value is not in the range of 0 to 32 767 it is considered invalid The factory default is 69 5 Press 4 lt paging channel gt This key sequence is used to set up your 1 to 4 digit initial paging channel When you turn on your Phonecell this channel helps the service provider find you and viceversa If the paging channel is not in the range of 1 to 1023 it is considered invalid NOTE channels 800 to 990 are invalid The factory default channel setting is 333 6 Press 7 lt band order gt 5S IT O N 21300 RIDGETOP CIRCLE STERLING VA 20166 WWW SUTRON COM 703 406 2800 703 406 2801 FAX SALES SUTRON COM TELULAR PHONECELL WITH THE 8210 SPEECH MODEM 6 This key sequence is used to enter the band order The band order value is a series of digits between 1 and 2 that must be at least 1digit and not more than 2 digits long The following table describes the relationship between the band order digits and EIA TIA 136 system