Sun StorEdge 6920 System Site Preparation Guide, Release 2.0

image

Contents

1. Sun microsystems Sun StorEdge 6920 System Site Preparation Guide Sun Microsystems Inc www sun com Part No 817 5224 10 May 2004 Revision 01 Submit comments about this document at http www sun com hwdocs feedback Copyright 2004 Sun Microsystems Inc 4150 Network Circle Santa Clara California 95054 U S A All rights reserved Sun Microsystems Inc has intellectual property rights relating to technology that is described in this document In particular and without limitation these intellectual property rights may include one or more of the U S patents listed at http www sun com patents and one or more additional patents or pending patent applications in the U S and in other countries This document and the product to which it pertains are distributed under licenses restricting their use copying distribution and decompilation No part of the product or of this document may be reproduced in any form by any means without prior written authorization of Sun and its licensors if any Third party software including font technology is copyrighted and licensed from Sun suppliers Parts of the product may be derived from Berkeley BSD systems licensed from the University of California UNIX is a registered trademark in the U S and in other countries exclusively licensed through X Open Company Ltd Sun Sun Microsystems the Sun logo AnswerBook2 docs sun com Solaris and Sun StorEdge are trademarks or registered
2. Environment 4 Electrical and Power Specifications 5 Physical Specifications 5 Physical Dimensions 6 Clearance and Service Access 6 Cabling Requirements 6 Collecting System Information 7 Planning the Storage Configuration 9 Sun StorEdge 6920 System Site Preparation Guide May 2004 v Preface The Sun StorEdge 6920 System Site Preparation Guide describes facilities requirements for installing a Sun StorEdge 6920 system Follow the guidelines as outlined in this document when planning your installation 6920 System Documentation The following is a list of documents related to the Sun StorEdge 6920 system For any document number with nn as a suffix use the most current document Part Number 816 5230 nn 817 5829 nn 817 5225 nn 817 5227 nn 817 5230 nn 817 5229 nn 817 5831 nn Preface Title Unpacking Guide Sun StorEdge 6920 System License Cards Sun StorEdge 6920 System Getting Started Guide Sun StorEdge 6920 System Regulatory and Safety Compliance Manual Sun StorEdge 6920 System Release Notes Sun StorEdge 6920 System Host Installation Software Guide Subject Unpacking instructions attached to the shipping container System license information System installation and initial configuration information System regulatory and safety information Late breaking information not included in the information set Instructions for software installation from CD System o
3. Site Preparation Guide May 2004
4. propriae intellectuels relatants la technologie qui est d crit dans ce document En particulier et sans la limitation ces droits de propri t intellectuels peuvent inclure un ou plus des brevets am ricains num r s http www sun com patents et un ou les brevets plus suppl mentaires ou les applications de brevet en attente dans les Etats Unis et dans les autres pays Ce produit ou document est prot g par un copyright et distribu avec des licences qui restreignent l utilisation la copie la distribution et la d compilation Aucune partie de ce produit ou document ne peut tre reproduite sous aucune forme par quelque moyen que ce soit sans l autorisation pr alable et crite de Sun et de ses bailleurs de licence s il y ena Le logiciel d tenu par des tiers et qui comprend la technologie relative aux polices de caract res est prot g par un copyright et licenci par des fournisseurs de Sun Des parties de ce produit pourront tre d riv es des syst mes Berkeley BSD licenci s par l Universit de Californie UNIX est une marque d pos e aux Etats Unis et dans d autres pays et licenci e exclusivement par X Open Company Ltd Sun Sun Microsystems le logo Sun AnswerBook2 docs sun com Solaris et Sun StorEdge sont des marques de fabrique ou des marques d pos es de Sun Microsystems Inc aux Etats Unis et dans d autres pays Toutes les marques SPARC sont utilis es sous licence et sont des marqu
5. rolling Do not use these pads to level the cabinet Placement of a Sun Product If you have ordered a Sun StorEdge 6920 system without an expansion cabinet make sure you allow enough room to install a second or third cabinet in the event that you want to expand your system Caution Do not block or cover the openings of your Sun product Never place a Sun product near a radiator or heat register Failure to follow these guidelines can cause overheating and affect the reliability of your Sun product Air cools the Sun StorEdge 6920 system cabinets from front to back Air enters at the front circulates and is expelled at the back of the cabinet The front and back door clearances provide sufficient space for cooling See TABLE5 for specific clearance specifications Facility Requirements This section contains the following information about the facility requirements for the Sun StorEdge 6920 system Environmental Requirements on page 4 m Electrical and Power Specifications on page 5 Physical Specifications on page 5 Site Preparation and Planning 3 Environmental Requirements The environmental requirements in TABLE 1 are the limits to which the systems are tested to ensure that they meet all functional requirements TABLE1 Facility Environmental Specifications Specifications Operating Nonoperating Temperature 41 F to 95 F 40 F to 76 F 5 C to 35 C 40 C to 60 C noncondensing
6. trademarks of Sun Microsystems Inc in the U S and in other countries All SPARC trademarks are used under license and are trademarks or registered trademarks of SPARC International Inc in the U S and in other countries Products bearing SPARC trademarks are based upon an architecture developed by Sun Microsystems Inc The OPEN LOOK and Sun Graphical User Interface was developed by Sun Microsystems Inc for its users and licensees Sun acknowledges the pioneering efforts of Xerox in researching and developing the concept of visual or graphical user interfaces for the computer industry Sun holds a non exclusive license from Xerox to the Xerox Graphical User Interface which license also covers Sun s licensees who implement OPEN LOOK BUIs and otherwise comply with Sun s written license agreements U S Government Rights Commercial use Government users are subject to the Sun Microsystems Inc standard license agreement and applicable provisions of the FAR and its supplements DOCUMENTATION IS PROVIDED AS IS AND ALL EXPRESS OR IMPLIED CONDITIONS REPRESENTATIONS AND WARRANTIES INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE OR NON INFRINGEMENT ARE DISCLAIMED EXCEPT TO THE EXTENT THAT SUCH DISCLAIMERS ARE HELD TO BE LEGALLY INVALID Copyright 2004 Sun Microsystems Inc 4150 Network Circle Santa Clara California 95054 Etats Unis Tous droits r serv s Sun Microsystems Inc a les droits de
7. 5 Physical Dimensions The values given in TABLE 4 are for the maximum hardware configuration TABLE4 System Physical Specifications System Height Width Depth Weight Sun StorEdge 6920 system base 75 in 23 9 in 37 in 1465 lb cabinet 190 5 cm 60 7 cm 94 cm 665 kg Sun StorEdge 6920 system with 75 in 47 8 in 37 in 3000 Ib one expansion cabinet 190 5 cm 121 4 cm 94 cm 1364 kg Sun StorEdge 6920 system with 75 in 71 7 in 37 in 4550 Ib two expansion cabinets 190 5 cm 182 1 cm 94 cm 2068 kg Clearance and Service Access TABLE 5 provides front and back physical clearance requirements for servicing the components in the system cabinet Refer to the Storage Automated Diagnostic Environment Service Advisor pages for specific service procedures TABLE5 Clearance and Service Access for the Sun StorEdge 6920 System Cabinet Access Location Clearance Needed Front 48 in 122 cm Back 36 in 92 cm Cabling Requirements When cabling the system follow these guidelines Keep the power and interface cables clear of walkways Route cables inside walls under the floor through the ceiling or in protective channels or raceways Route interface cables excluding fiber optic cables away from motors and other sources of magnetic or radio frequency interference 6 Sun StorEdge 6920 System Site Preparation Guide May 2004 Do not exceed cable length limitations TABLE 6 shows the cable specifications
8. Precautions on page 2 Secure Installation Requirements on page 3 m Placement of a Sun Product on page 3 Note Do not make mechanical or electrical modifications to the equipment Sun Microsystems Inc is not responsible for regulatory compliance of a modified Sun product Handling Precautions Caution A fully configured Sun StorEdge 6920 system cabinet can weigh in excess of 1400 pounds 627 kg Ensure that all surfaces this system will move over can withstand this load The cabinet is equipped with wheels so that you can move it Use enough personnel when moving the cabinet especially on sloped loading docks and ramps to gain access to a raised computer room floor Move the cabinet slowly and deliberately and make sure that the floor is free from foreign objects and cables that the cabinet could roll over Caution To avoid injury wear protective footwear when moving a system A 2 Sun StorEdge 6920 System Site Preparation Guide May 2004 Secure Installation Requirements To minimize personnel injury in the event of a seismic occurrence you must securely fasten the cabinet to a rigid structure extending from the floor to the ceiling or from the walls of the room in which the cabinet is located Install the cabinet on a level surface At each corner on the base of the cabinet are adjustable nonskid pads Extend these pads when the cabinet is installed to prevent the cabinet from
9. and Maximum Length 328 084 ft 100 m 82 021 ft 25 m Not applicable lengths TABLE6 Cable Specifications Cable Type Connector Shielded Ethernet RJ 45 10 100BASE T category 5 Serial RJ 45 Available only to qualified field service representatives Power 220V Standard The power cables are the standard ones shipped with the Sun StorEdge system The cables that connect two cabinets together are standard Fibre Channel FC cables Collecting System Information Before beginning the installation prepare the site and gather the information that you will need to perform the installation To do this refer to the worksheet on page 8 Caution The Sun StorEdge 6920 system uses the private network addresses 10 0 0 x and 192 168 0 x Therefore do not use these addresses when connecting directly to the Sun StorEdge 6920 system If your network uses these addresses ensure that they are behind a firewall as dictated by the network RFCs Site Preparation and Planning 7 Use this worksheet to collect the information you will need during the system installation Sun StorEdge 6920 System Configuration Worksheet Sun StorEdge 6920 System ID 0 7 o Sun StorEdge 6920 System IP Address oO Sun StorEdge 6920 System Network Mask Name Server Domain Name IP Address of the Domain Name Server DNS Gateway IP Address Telephone Number analog phone line for remote monito
10. cations All Sun StorEdge 6920 systems require two independent power sources Each Short Name all caps cabinet has two power conditioners for redundancy mounted in the base of the cabinet To maintain the power redundancy each conditioner must be connected to an independent power source TABLE 3 lists the power required for each conditioner TABLE3 Power Specifications for Each Cabinet Specification Rating AC voltage rating 200 to 240 VAC AC voltage range 180 to 264 VAC Frequency range 50 to 60 Hz single phase Current at 240 VAC 32A Power consumption maximum Sun StorEdge 6920 system base cabinet 4 2 kW Sun StorEdge 6920 system with one 8 4 kW expansion cabinet The following is recommended for all installations m All AC mains and supply conductors to power distribution boxes for the system cabinet must be enclosed in a metal conduit or raceway when specified by local national and or other applicable government codes and regulations The supply conductors and power distribution boxes or equivalent metal enclosures must be grounded at both ends The supplied Short Name all caps s require voltages within minimum fluctuation The facilities voltage at the customer facility must not vary by more than 5 m The customer facilities must provide suitable surge protection Physical Specifications This section contains the physical requirements for the Sun StorEdge 6920 system Site Preparation and Planning
11. e Default profile to specify its storage parameters The default storage profile is RAID level RAID 5 Segment size 64 Kbyte Read ahead mode On Number of drives variable Array type Best Available Match Bandwidth Number of disks variable Dedicated hot spare No Virtualization strategy Stripe Stripe size 1 Mbyte Storage domains Storage profiles Storage Configuration Options Continued Configuration Options You can choose either of the following options when configuring storage pools Use the existing default configuration as is Create a new storage pool You can choose any of the following options when configuring storage pools Use the existing default configuration Move the default RAID 5 virtual disk to a new pool e Delete the RAID 5 virtual disk and create a different virtual disk in a new pool You must configure volumes TABLE 7 Default Configuration All virtual disks are in one storage pool Default Virtual disks are preconfigured at the factory as based on the number of drives ordered for your system The virtual disks are configured as RAID 5 If an array has 7 drives per tray all 7 drives are configured as a single RAID 5 virtual disk If an array has 14 drives the tray is configured as two RAID 5 virtual disks The default configuration does not include predefined volumes Storage pools Virtual disks Volumes 10 Sun StorEdge 6920 System
12. es de fabrique ou des marques d pos es de SPARC International Inc aux Etats Unis et dans d autres pays Les produits protant les marques SPARC sont bas s sur une architecture d velopp e par Sun Microsystems Inc L interface d utilisation graphique OPEN LOOK et Sun a t d velopp e par Sun Microsystems Inc pour ses utilisateurs et licenci s Sun reconna t les efforts de pionniers de Xerox pour la recherche et le d veloppement du concept des interfaces d utilisation visuelle ou graphique pour l industrie de l informatique Sun d tient une license non exclusive de Xerox sur l interface d utilisation graphique Xerox cette licence couvrant galement les licenci es de Sun qui mettent en place l interface d utilisation graphique OPEN LOOK et qui en outre se conforment aux licences crites de Sun LA DOCUMENTATION EST FOURNIE EN L TAT ET TOUTES AUTRES CONDITIONS DECLARATIONS ET GARANTIES EXPRESSES OU TACITES SONT FORMELLEMENT EXCLUES DANS LA MESURE AUTORISEE PAR LA LOI APPLICABLE Y COMPRIS NOTAMMENT TOUTE GARANTIE IMPLICITE RELATIVE A LA QUALITE MARCHANDE A L APTITUDE A UNE UTILISATION PARTICULIERE OU A L ABSENCE DE CONTREFA ON Ob com ca Adobe PostScript Contents Preface v Site Preparation and Planning 1 Customer Obligations 1 Safety Information 2 Handling Precautions 2 Secure Installation Requirements 3 Placement of aSun Product 3 Facility Requirements 3 Environmental Requirements 4 Recommended Operating
13. instructions and other information about Brocade and McData Fibre Channel switches refer to the product documentation provided by the vendor Sun StorEdge 6920 System Site Preparation Guide May 2004 Accessing Sun Documentation Online You can view print or purchase a broad selection of Sun documentation including localized versions at http www sun com documentation For Sun StorEdge 6920 system documentation go to http www sun com products n solutions hardware docs Network_Storage_Solutions Midrange 6920 index html Contacting Sun Technical Support If you have technical questions about this product that are not answered in this guide go to http www sun com service contacting Sun Welcomes Your Comments Sun is interested in improving its documentation and welcomes your comments and suggestions You can submit your comments by going to http www sun com hwdocs feedback Please include the title and part number of this document with your feedback Sun StorEdge 6920 System Site Preparation Guide part number 817 5224 10 Preface vii viii Sun StorEdge 6920 System Site Preparation Guide May 2004 Site Preparation and Planning This document provides the information you need to prepare your site before installing the Sun StorEdge 6920 system Follow the guidelines as outlined in this document when planning your installation To determine the complete list of components and Sho
14. noncondensing Relative humidity 10 to 90 noncondensing 93 noncondensing maximum gradient 10 per hour maximum gradient 10 per hour Altitude 9 840 feet 39 370 feet 3 000 meters 12 000 meters Avoid temperature extremes and keep the work area clean Maintain the operating conditions described in TABLE 2 The Short Name all caps typically resides in a computer room environment that provides control over environmental factors such as temperature humidity and airborne dust A computer room installation can also help protect equipment from fire flood or other danger originating in the building Recommended Operating Environment The operating environmental limits in TABLE 1 reflect what the systems have been tested to in order to meet all functional requirements The optimum operating condition in TABLE 2 is the recommended operating environment Operating computer equipment for extended periods of time at or near the temperature or humidity extremes is known to significantly increase the failure rate of hardware components To minimize any chance of down time due to component failure plan to use the optimal temperature and humidity ranges TABLE2 Facility Optimal Environmental Specifications Environmental Factor Ambient Temperature Range Ambient Relative Humidity Operating 70 F to 73 5 F 21 C to 23 C 45 to 50 Sun StorEdge 6920 System Site Preparation Guide May 2004 4 Electrical and Power Specifi
15. ring Site Address another host on your network Sun StorEdge 6920 System Site Preparation Guide May 2004 Email Notification Address Host IP Address O Host Bus Adapter HBA WWNs 8 Planning the Storage Configuration After you collect the information you will need and before you actually configure the system you must determine how to configure your Sun StorEdge 6920 system according to your needs and the needs of your clients Use TABLE 7 as a guide for planning your site storage configuration For more information about specific features and configuration options see the Sun StorEdge 6920 System Getting Started Guide and the online help system Configuration Options You can choose either of the following options when configuring storage domains Use the existing default configuration as is e Create a custom storage domain You can choose any of the following options when configuring storage profiles Use the existing default configuration as is e Select one of the predefined storage profiles shipped with the system Create a custom storage profile Site Preparation and Planning 9 Help TABLE7 Storage Configuration Options Default Configuration All storage elements are in one storage domain DEFAULT which can be accessed by all hosts initiators The default storage domain uses th
16. rt Name all caps s your shipment will include consult your local Sun sales representative For a product overview and installation instructions refer to the Sun StorEdge 6920 System Getting Started Guide This document contains the following sections m Customer Obligations on page 1 Safety Information on page 2 Facility Requirements on page 3 Cabling Requirements on page 6 m Collecting System Information on page 7 m Planning the Storage Configuration on page 9 Customer Obligations The customer is obliged to inform Sun Microsystems Inc of any and all ordinances and regulations that might affect the installation The customer is responsible for meeting all government codes and regulations concerning facilities The customer is also required to do the following Comply with all local national and international codes covered in this specification The subjects covered include fire and safety building and electrical codes Document and inform Sun Microsystems Inc of any deviations from this specification Safety Information Install the Sun StorEdge 6920 system in accordance with the local safety codes and regulations at the facility site Make sure that you read the safety precautions in the Sun StorEdge 6920 System Regulatory and Safety Compliance Manual The following sections contain additional safety information for the local facility Handling
17. verview information as well as information on system configuration maintenance and basic troubleshooting is covered in the online help included with the software In addition the sscs 1M man page provides information about the commands used to manage storage using the command line interface CLI Related Documentation The following documents provide detailed information if needed about system components Part Number 875 3364 nn 817 0064 nn 817 0770 nn 817 0977 nn 817 0062 nn 817 0063 nn 805 3067 nn 816 2756 nn 816 4468 nn Title Sun StorEdge Network 2Gb FC Switch 8 SANbox2 8c Installer s User s Manual Sun StorEdge Network 2Gb FC Switch 8 and Switch 16 FRU Installation Sun StorEdge Network 2Gb FC Switch 8 and Switch 16 Release Notes Sun StorEdge Network 2Gb FC Switch 64 Release Notes Sun StorEdge Network 2Gb Brocade SilkWorm 3200 3800 and 12000 Switch 3 1 4 1 Firmware Guide to Documentation Sun StorEdge 2Gb McData Intrepid 6064 Director Guide to Documentation Sun StorEdge Expansion Cabinet Installation and Service Manual Sun Fire V100 Server User s Guide Solaris Handbook for Sun Peripherals Product Sun StorEdge network Fibre Channel switch 8 switch 16 and switch 64 Sun StorEdge Brocade switch documentation Sun StorEdge McData switch documentation Expansion cabinet Storage Service Processor Solaris Operating System Related Vendor Documentation For installation

Download Pdf Manuals

image

Related Search

Related Contents

LG 42LV4400 Specification Sheet  HP XB4000 User's Manual  User Manual POI-1501  Samsung Galaxy Note (8.0, Wi-Fi) Instrukcja obsługi  Manual de Instruções  Art.-Nr. 16612 Intelligentes Batterieladegerät EAL  StarTech.com 2m Cisco Compatible SFP+ 10-Gigabit Ethernet (10GbE) Passive Twinax Direct Attach Cable  Benutzen des Notebooks  PLANO DE AÇÕES ARTICULADAS (PAR) - CDI  TITAN 12 • 2-way Passive Loudspeaker  