Home
SUUNTO COMBOS AND MECHANICAL
Contents
1. s intended zone the more the needle will tilt In extreme situations the needle might stick For this reason it is very important to know in which country the compass will be used Compass zone map SUUNTO Mechanical Gauges Suunto depth gauge SM 16 Models available 45 m 70 m 150 ft 230 ft Suunto pressure gauge SM 36 Models available 300 bar and 4000 psi Before usage Depth gauge Before diving check the position of the depth indicating pointer Atmospheric conditions altitude temperature may cause he point to not indicate zero If this is the case turn the adjusting screw located at the right side of the gauge to align the pointer to zero The adjustment is to be made at the temperature of usage Repeated unnecessary adjustments may cause excessive wear to the seals and eventual leakage CAUTION Do not attempt to adjust the water entry port located at the left side of gauge Tampering with the port can cause damage to internal components Do not pressure test gauge in air Always immerse the gauge in water while pressure testing it Pressure gauge The hose has an end fitting with 7 16 20 UNF thread If your regulator has a different thread size in the high pressure HP output port ask your dealer for the correct adapter Always inspect the o ring at the male thread to be sure it is clean and undamaged before connecting it to the regulator Always turn your air supply on slowly Always turn the pre
2. C to 40 C 32 F to 104 F Storage temperature 20 C to 50 C 4 F to 122 F SM 36 Operating and storage temperature 0 C to 40 C 32 F to 104 F Technical Specifications The Suunto depth gauge SM 16 complies with the prEN 13319 standard The tolerances for depth gauges are At 3m 0 8 0 4m At 6m 0 8 0 4m At 9m 0 8 m At 15m 1 1 2m At 30m 1 1 2m At 45m 1 1 5m At 60m 1 1 5m The SM 36 pressure gauges comply with the EN 250 standard The tolerances for pressure gauges measured at decreasing pressure are At 40bar 5 bar At 100bar 10 bar At 200bar 10 bar At 300bar 10 bar 10 Suunto Limited Warranty Suunto warrants that during the Warranty Period Suunto or a Suunto Authorized Service Center hereinafter Service Center will at its sole discretion remedy defects in materials or workmanship free of charge either by a repairing or b replacing or c refunding subject to the terms and conditions of this Limited Warranty This Limited Warranty is only valid and enforce able in the country of purchase unless local law stipulates otherwise Warranty Period The Limited Warranty Period starts at the date of original retail purchase The Warranty Period is two 2 years for display devices The Warranty Period is one 1 year for accessories and consumable parts including but not limited to chargeable batteries chargers docking stations straps cables and hoses Exclusions and Limit
3. at the dive site paying special attention to memorizing the direction of the shoreline and bearings of landmarks that may be of importance Natural aids to underwater navigation The underwater extension of the shore s inclination tells the diver if he is following the shoreline Be careful however as underwater ridges may lead you astray Surface occasionally to check your position The dip and stratification of rocks on the shore can often be followed over large areas under water 6 Sand ripples usually form long lines parallel to the shore The direction of currents should be noted by their effect on algae or drifting particles Use the compass to check the bearing of the current In shallow water the sun s direction can be seen from shadows on the bottom or by looking towards the surface Swimming in a straight line along the bottom is greatly facilitated if you can line up three distinctive objects in your line of vision As you reach the first one line up a new one farther away so that you again have three points determining your course This way you can counteract the effects of side current Compass Balancing The horizontal and vertical components of earth s magnetic field vary in different locations For this reason Suunto compass es are balanced for 2 different zones If the compass is used in an adjacent balancing zone the compass needle will tilt only slightly However the farther the compass is used from it
4. ations This Limited Warranty does not cover 1 a normal wear and tear b defects caused by rough handling or c defects or damage caused by misuse contrary to intended or recommended use 2 user manuals or any third party items 3 defects or alleged defects caused by the use with any product accessory software and or service not manufac tured or supplied by Suunto 4 replaceable batteries This Limited Warranty is not enforceable if item 1 has been opened beyond intended use 2 has been repaired using unauthorized spare parts modified or repaired by unauthorized Service Center 3 serial number has been removed altered or made illegible in any way as determined at the sole discretion of Suunto 4 has been exposed to chemicals including but not limited to mosquito repellents Suunto does not warrant that the operation of the Product will be uninterrupted or error free or that the Product will work with any hardware or software provided by a third party Access to Suunto warranty service You must have proof of purchase to access Suunto warranty service For instructions how to obtain warranty service visit www suunto com warranty contact your local authorized Suunto retailer or call Suunto Help Desk 358 2 2841160 national or premium rates may apply 11 Limitation of Liability To the maximum extent permitted by applicable mandatory laws this Limited Warranty is your sole and exclusive remedy and is in lieu of all other wa
5. en SUUNTO COMBOS AND MECHANICAL INSTRUMENTS INSTRUCTION MANUAL Combo Consoles Console Compasses CB 71 STD and CB 71 DS Depth Gauge SM 16 Pressure Gauge SM 36 SUUNTO Combo Consoles Introduction The Suunto combo consoles for recreational use allow you to create a personal combo according to your own specific needs Analog gauges dive computers and compasses fit together like building blocks The combos consist of four main modules the pressure gauge module the instrument module and two different compass modules The pressure gauge module is designed for the Suunto pressure gauges and it can also be used with the new Suunto Quick Release QR The basic combinations are displayed below CB 71 SK 7 STD CB TWO CB ONE CB 71 SK 7 DS CB DOUBLE CB IN LINE CB DOUBLE IN LINE CB IN LINE fee Assembling the Combo Modules 1 CB ONE module front cover with SM 36 pressure gauge in place see section CB ONE Module assembly 2 CB IN LINE module front cover 3 CB end piece or CB 71 STD compass optional 4 CB IN LINE module back cover with instrument 5 CB ONE module back cover or CB 71 DS compass optional 3 CB ONE Module Assembly The CB ONE Module is designed to fit the Suunto SM 36 analog pressure gauges Before assembling the CB ONE module the hose cover needs to be fitted on the pressure hose The hose cover ensures that the SM 36 pressure gauge fits properly on the CB ONE module If the Suun
6. needle will sting The SK 7 compass may however be inclined about 30 degrees Sighting a compass bearing Hold the compass so that the compass is in a horizontal position and the direction line points away from you Turn with the compass until the direction line points at your destination then turn the direction ring until the magnetic North needle is aligned between the slit marks The front end of the direction line on the SK 7 shows your compass bearing and as long as he North needle is aligned between the slit marks the direction points toward your destination The SK 7 compasses also have a side reading window which also enables you to take a bearing by directing the compass towards the destination and by reading the compass bearing from the side window This bearing can be memorized by turning the direction ring to hat bearing Setting a given bearing or direction The scale division on the SK 7 is 360 degrees clockwise from 0 degrees at North Turn the direction ring until the front end of the direction line is at the desired direction Turn the compass until the needle falls between the slit marks The direction ine now points in the desired direction Magnetic declination Maps and marine charts are drawn in correlation to the geographic poles while the magnetic compass needle is subject to magnetic declination which varies according to the location General orientation on the diving site Before diving check the main compass bearings
7. rranties expressed or implied Suunto shall not be liable for special incidental punitive or consequential damages including but not limited to loss of anticipated benefits loss of data loss of use cost of capital cost of any substitute equipment or facilities claims of third parties damage to property resulting from the purchase or use of the item or arising from breach of the warranty breach of contract negligence strict tort or any legal or equitable theory even if Suunto knew of the likelinood of such damages Suunto shall not be liable for delay in rendering warranty service 12 IJ SUUNTO HELP DESK GLOBAL 358 2 284 1160 USA toll free 1 800 543 9124 CANADA toll free 1 800 267 7506 www suunto com SUUNTO Suunto Oy 11 2005 09 2006 11 2011 All rights reserved Suunto is a registered trademark of Suunto Oy
8. ssure gauge dial face away from your face when turning on the air supply Do not overtighten the hose at the gauge the fitting is pressure proof even when tightened with fingers Service Avoid subjecting the gauges to excessive shock loads such as those that might occur from being dropped or hit against an 8 immovable object Do not subject the gauges to pressures beyond their maximum range Temperature extremes can be damaging In general the gauges should not be exposed to temperatures to which you would not expose yourself CAUTION After use rinse the gauges or the console with fresh water and store them out of direct sunlight in a dry place at room temperature CAUTION Do not attempt to clean the gauges with anything other than water Use of cleaning agents or compressed air can cause permanent damage The introduction of any probe into the water entry port of the depth gauge or the pressure relief valve opening of the pressure gauge can also damage internal components Before prolonged storage the instruments should be removed from the console rinsed with fresh water and stored separately CAUTION Do not attempt to disassemble the gauges Special tools and training are required to perform the adequate service The instruments must be serviced by an authorized dealer every second year or after 200 dives whichever comes first Operating and Storage Temperatures SM 16 Operating temperature 0
9. to Quick Release is used the hose cover is not to be used See section CB ONE module assembly using the SUUNTO Quick Release After attaching the hose cover the pressure hose and gauge are assembled on the CB ONE front cover according to the picture After the pressure gauge is in place the CB ONE back cover or alternatively the CB 71 SK 7 DS compass is attached with four screws 4 CB ONE Module Assembly when using the SUUNTO Quick Release If the SUUNTO Quick Release QR is used the hose cover should be attached on the high pressure hose below the female end of the QR The male part is attached to the pressure gauge which is then fitted onto the CB ONE front cover according to the picture below CB IN LINE Module Assembly The CB IN LINE module fits the Suunto Vyper and Zoop dive computers or the SM 16 round depth gauge The Vyper locks in place on the IN LINE module back cover For the other instruments there are lugs on the back cover aiding the orientation The Suunto Vyper and Zoop are delivered with a display shield 5 SUUNTO Console Compasses CB 71 SK 7 STD and CB 71 SK 7 DS The CB 71 SK 7 is available in two versions the CB 71 SK 7 STD for attachment on top of the combo modules or the Cobra dive computer and the CB 71 SK 7 DS for attachment on the back side of the CB ONE module Compass use for divers General instructions Usually a compass must be held precisely in a horizontal position otherwise the
Download Pdf Manuals
Related Search
Related Contents
2014.9.30 No.346 Whirlpool RS6700XV User's Manual Manual de instruções MANUAL DE USUARIO DE LA APLICACIÓN “CONSULTA Bosch A5 User's Manual Calorex Pro-Pac 8-22kw User Manual Designer Reference Manual EL160.80.50 Small Graphics Display USER`S MANUAL FRULLATORE TVWall User`s Manual 4.1 - ZENIT IP Surveillance Cameras Copyright © All rights reserved.
Failed to retrieve file