1. c configure When you set mpxio disable no in the scsi_vhci conf file a simple reboot causes extra device paths to appear in dev dsk The command reboot r corrects the problem The extra paths in dev dsk and dev rdsk point to physical devices and you should never use them Correct device paths for the Sun Chapter 3 Known Issues 31 StorEdge A1000 A3x00 and A3500FC arrays have rdnexus in them Do not enable the mpxio setting in any way as described on page 9 under the section Limitations in RAID Manager 6 22 1 on page 7 m 4492436 LUNS Of New Sun StorEdge A1000 Arrays Are Not Seen From format When You Use Just hot_add On the Solaris 8 Operating Environment Adding a Sun StorEdge A1000 array to a host and using hot __add 1m is not sufficient to make format see the array s LUNs using the Solaris 8 operating environment The RAID Manager 6 commands work but the device paths in dev dsk are not correct causing format and other user accesses to fail Do a reconfiguration reboot of the host after the hot_add command to repair the device paths in dev r dsk m 4494030 The RAID Manager 6 22 Recovery Guru Battery Replacement Procedure Is Incorrect The battery replacement text in the Recovery Guru has not been updated to reflect the new battery replacement procedure The current text says the RAID module should be powered off when the battery is removed and replaced The following two procedures explain how to replace old and
2. Notes dialog click OK 5 In the Select Upgrade Type window click Offline 6 Enter usr lib osa fw NVSRAMfile in the path field where NVSRAMfile is the NVSRAM file from TABLE 2 1 Click OK in the Offline Firmware Upgrade dialog 7 Power cycle each controller to activate the new NVSRAM Do not reboot the host computer rebooting the host does not activate the NVSRAM Note After you download the RAID Manager s firmware and NVSRAM during a fresh installation or an upgrade you can verify that the new NVSRAM is installed with the raidutil c device i command The module profile should show a revision of 0003 Non root Access to Raw Partitions To close a security hole described in bug 4352516 listed in the Sun StorEdge RAID Manager 6 22 Release Notes 805 7758 12 RAID Manager 6 22 1 does not allow users not logged in at the root level to open raw partitions If you are using a database management system such as Oracle or Sybase or if you put logs data or database data directly on partitions you may have difficulty accessing your files You can use one or more of the following workarounds Chapter 2 Late Breaking Information 5 a Put a volume manager on top of the raw partitions You can use VERITAS Volume Manager or a file system such as UFS for a volume manager m If the system has only Sun StorEdge A1000 arrays on it set Rdac_SupportDisabled TRUE in the etc raid rmparams directory and then reboot the system
3. are not reported normally but the read can not be completed because the LUN is already degraded In order to complete reconstruction perform a surface check to determine which drive has the problem dd if dev rdsk c6t4d1s2 of dev null bs 512k m 4471208 RAID Manager 6 Causes a Mismatch In Controller Numbers In dev cfg Using cfgadm shows incorrect controller numbers when you install RAID Manager 6 22 or 6 22 1 RAID Manager 6 does not update the dev cfg directory links with its controller numbers The output of cfgadm shows a wrong controller number in the first column but the device paths are correct m 4477032 Solaris 8 10 00 With RAID Manager 6 22 Generates High Controller Numbers If you have controller numbers for RAID Manager 6 LUN s above 63 for example c72t4d0s0 then these LUNs will not behave properly Correct entries in dev dsk which are for RAID Manager 6 LUNs show rdnexus in the device path when you use the command 1s 1 For example ls dev dsk c0t5d0s0 Irwxrwxrwx 1root root 44 Jul 18 16 27 cOt5d0s0 gt devices pseudo rdnexus 0 rdriver 5 0 a Any dev dsk or dev rdsk entry which does not contain rdnexus is not usable m 4479887 RDAC Open Failure Messages When an Oracle or Sybase RDBMS Accesses Raw LUN Devices Access to raw partitions can only be safely accomplished by user 0 root By default the raw partitions belong to root If their ownership has been changed to a non root
4. arrays whose identifiers are listed The default settings are Rdac_HotAddDisabled PARTIAL and Rdac_HotAddIDs 4 5 The easiest way to correct this is to set Rdac_HotAddDisabled FALSE for systems where the Fibre Channel arrays might have a variety of loop IDs Then reboot the host system or restart the rdriver However on systems with SCSI Sun StorEdge A3x00 or A1000 arrays add SCSI identifier numbers to the rmparams file list For example if your system has arrays with SCSI identifier 6 and 8 as well as 4 and 5 edit rmparams to say Rdac_HotAddIDs 4 5 6 8 Then reboot the system for the new configuration to be active m The following error message might occur when you use RAID Manager 6 22 1 if you are adding LUNs or resetting the configuration drvconfig driver failed to attach ssd If your system has no Sun StorEdge A3500FC arrays edit the rmparams file to speed booting and hot_add To edit the file remove ssd from the line Rdac_NativeScsiDrivers sd ssd m The controllers must be in an optimal state before an installation To determine the state of the controllers see the Sun StorEdge A3500 A3500FC Controller Module Guide to determine the meaning of the LED patterns If the array controllers are not in optimal state contact your service representative A controller might go offline during installation of a Solaris operating system in a Fibre Channel loop configuration You can avoid this by detaching the arrays before beginni
5. not deleting LUN 0 LUN 0 comes from the factory on all arrays as a 10 Mbyte RAID 0 device which is not a useful size Historically LUN 0 had to be resized to be used but that is accomplished only by deleting it and recreating it However all Solaris drivers support multiple LUNs per array so LUN 0 can be left alone Chapter 2 Late Breaking Information 23 v To Reset the Factory Default Configuration of the Entire Array 1 Select Configuration gt File gt Reset Configuration in the GUI Reset Configuration This step leaves a default LUN 0 on controller A 2 Make sure you always use the path to a controller with at least one LUN on it when using the CLI version raidutil c lt module specifier gt X Do not use the command raidutil D all v To Create a Default LUN 0 If the array gets into a state where there is no LUN 0 power the array off and back on which causes it to go through Start of Day SOD processing SOD processing creates a default LUN 0 In this case only the controller modules must be power cycled not all the trays A host reboot does not accomplish the same thing Resetting the Configuration Follow these guidelines to reset the configuration on a Sun StorEdge A3x00 SCSI system or Sun StorEdge A3500FC system m Ensure that controller A owns at least one LUN m Resetting the configuration does not remove the device paths When using the Solaris 7 11 99 operating system or a compatible version usin
6. on nvutil command succeeded v To Install RAID Manager 6 22 1 1 Install the appropriate packages with pkgadd Four of the five necessary packages and their loading instructions are described in the Sun StorEdge RAID Manager 6 22 Installation and Support Guide for Solaris The newest package Sunosanv contains the NVSRAM files and is not listed in the guide and is necessary 2 Download the RAID Manager firmware a If you are installing RAID Manager for the first time refer to the Sun StorEdge RAID Manager 6 22 Installation and Support Guide for Solaris for procedures to download the firmware listed in Table 2 2 on page 14 Chapter 2 Late Breaking Information 11 a If you are upgrading RAID Manager refer to the Sun StorEdge RAID Manager 6 22 1 Upgrade Guide for procedures to download the firmware listed in Table 2 2 on page 14 Refer to bug 4488704 on page 31 for more information 3 Download the NVSRAM and power cycle the controllers Refer to To Install New NVSRAM with the RAID Manager 6 22 1 Upgrade on page 5 The following issues are specific to the installation of RAID Manager 6 22 1 Installation Issues m You must edit the rmparams file on systems with Fibre Channel loops with more than two Sun StorEdge A3500FC arrays or any system where the loop SCSI identifiers on the arrays are not the factory settings 4 and 5 The rmparams file specifies that hot adding of arrays is disabled for all but those
7. 11 6 1 1 Update 1 with Patch ID 106513 02 2 05 02 14 6 1 1 Update 1 with Patch ID 106707 01 2 05 02 15 6 1 1 Update 2 2 05 02 32 6 1 1 Update 2 with Patch ID 106513 03 2 05 02 32 6 1 1 Update 2 with Patch ID 106513 04 2 05 06 33 6 1 1 Update 2 with Patch ID 106707 02 2 05 02 32 6 22 3 01 02 35 6 22 with Patch ID 108834 01 3 01 03 54 6 22 with Patch ID 108834 03 3 01 03 54 6 22 with Patch ID 108553 03 3 01 03 54 6 22 with Patch ID 108834 07 3 01 03 60 6 22 with Patch ID 108553 07 3 01 03 60 6 22 1 3 01 04 68 t If your controller appware is below level 2 04 04 01 you must first upgrade to level 2 04 04 01 before upgrading to level 2 05 02 xx level 2 04 04 01 is provided on the RAID Manager 6 22 1 CD Before upgrading to level 3 01 02 xx you must first upgrade to level 2 05 06 32 level 2 05 06 32 is provided on the RAID Manager 6 22 1 CD For a complete list of firmware levels supported by all earlier versions of Sun StorEdge RAID Manager software see the Sun StorEdge RAID Manager Installation 6 22 and Support Guide 805 7756 14 Sun StorEdge RAID Manager 6 22 1 Release Notes January 2003 For detailed instructions on upgrading controller firmware refer to the Sun StorEdge RAID Manager 6 22 User s Guide 806 0478 and the Sun StorEdge RAID Manager 6 22 and 6 22 1 Upgrade Guide 806 7792 Upgrading the Solaris Environment With RAID Manager 6 22 1 Already Installed Note Before upgrading to the Solaris 2 6 and hig
8. 22 Release Notes 805 7758 12 Topics in this chapter include Late Breaking Bugs on page 29 Resolved Bugs Listed by Priority on page 33 Late Breaking Bugs The following is a list of new bugs you might encounter and recommended actions when using RAID Manager 6 22 1 Bug 4381439 Logical Links Not Cleaned Up Under dev r dsk Directory When you delete LUNs the RAID Manager does not remove their paths in the dev directory Do not be concerned the open 2 system call and commands like format 1m discover there is no device behind the path and the commands fail appropriately The commands fail even if you use the CLI raidutil x or the GUI setting which is Configuration gt File gt Reset Configuration Bug 4399135 Write Cache Mirroring With Independent Controller Configuration Not Supported When two controllers in a control module are configured in independent controller mode you can still enable write cache mirroring This is not supported so do not do it 4459961 System Response Degrades When a Drive Fails In a LUN With a Single CPU On small servers where there is only one CPU a degraded LUN can cause much reduced response times for the user at the console This is particularly true when VxVM is also in use 4477099 For the A3500 array RAID 5 Reconstruction Fails to Spare a Disk 29 When a RAID 5 LUN is being reconstructed a read error might occur on the remaining part of the LUN Read errors
9. 805 7854 contains incorrect text in the procedure To Determine Whether to Upgrade or Downgrade the New Controller Firmware The current instructions say you should upgrade the firmware The text should say Earlier than the universal controller FRU downgrade the controller firmware The statement that follows should say to upgrade the controller firmware instead of downgrade the controller firmware For complete instructions refer to FIN 10553 Sun StorEdge RAID Manager 6 22 1 Release Notes January 2003 Installing and Uninstalling RAID Manager 6 22 1 If you are jumpstarting RAID Manager 6 22 1 for the first time the application gets NVSRAM warnings because the NVSRAM is not yet loaded You can ignore these messages For example The Status notification bit disabled NVSRAM field of controller c2t5d0 1T93401584 at offset Oxld is invalid The value is 0x0 the valid value should be 0x80 The Bus device reset message NVSRAM field of controller c2t5d0 1T93401584 at offset 0x28 is invalid The value is Oxc the valid value should be0x2c The Product revision level NVSRAM field of controller c2t5d0 1T93401584 at offset 0x33 is invalid The value is 0x1 the valid value should be 0x5 The incorrect NVSRAM settings of controller c2t5d0 1T93401584 have been fixed The new settings will not take effect until the controller is reset While the subsystem is idle turn the controller module off then back
10. 93 listed in the Sun StorEdge RAID Manager 6 22 Release Notes 805 7758 12 RAID 0 LUNs do not reformat after you replace a drive When a disk drive in a RAID 0 LUN fails data is lost because the definition of RAID 0 is that there is no redundancy Users often provide redundancy by mirroring the LUN with a volume manager When a drive fails in such a LUN you can replace the drive and RAID Manager 6 notices the new drive and marks the LUN optimal The optimal designation only means the drive is ready for reformatting and reloading of the data However if the volume manager is running but not accessing the LUN with the failed drive it might not be aware the data was lost Do not let the volume manager continue to run while the drive is replaced because it might never be aware of the data loss and could access the new data on the replaced drive before it is reformatted and reloaded causing corruption of the data in the mirror Moving Drives Between Sun StorEdge Array Subsystems Do not move drives from one RAID module to another Sun StorEdge A1000 or A3x00 because this is not supported You can add drives to a Sun StorEdge A3x00 or A3500FC array system that is already running for the purpose of adding disk capacity However if the added drives are being moved from another Sun StorEdge A1000 A3x00 or A3500FC system or were once installed on another Sun StorEdge A1000 A3x00 or A3500FC array system delete any LUNs configured on those drive
11. ISCLAIMED EXCEPT TO THE EXTENT THAT SUCH DISCLAIMERS ARE HELD TO BE LEGALLY INVALID Copyright 2003 Sun Microsystems Inc 4150 Network Circle Santa Clara California 95054 Etats Unis Tous droits r serv s Sun Microsystems Inc a les droits de propri t intellectuels relatants a la technologie incorpor e dans le produit qui est d crit dans ce document En particulier et sans la limitation ces droits de propri t intellectuels peuvent inclure un ou plus des brevets am ricains num r s a http www sun com patents et un ou les brevets plus suppl mentaires ou les applications de brevet en attente dans les Etats Unis et dans les autres pays Ce produit ou document est prot g par un copyright et distribu avec des licences qui en restreignent l utilisation la copie la distribution et la d compilation Aucune partie de ce produit ou document ne peut tre reproduite sous aucune forme parquelque moyen que ce soit sans l autorisation pr alable et crite de Sun et de ses bailleurs de licence s il y ena Le logiciel d tenu par des tiers et quicomprend la technologie relative aux polices de caract res est prot g par un copyright et licenci par des fournisseurs de Sun Des parties de ce produit pourront tre d riv es des syst mes Berkeley BSD licenci s par l Universit de Californie UNIX est une marque d pos e aux Etats Unis et dans d autres pays et licenci e exclusivement par X Open Company Ltd
12. ITE MARCHANDE A L APTITUDE A UNE UTILISATION PARTICULIERE OU A L ABSENCE DE CONTREFA ON SA Ca Adobe PostScript Contents About These Release Notes 1 Late Breaking Information 3 Changes in RM6 22 1 4 Upgrading RAID Manager 4 NVSRAM Installation for Upgrading and Installing RAID Manager 4 v To Install New NVSRAM with the RAID Manager 6 22 1 Upgrade 5 Non root Access to Raw Partitions 5 Additional Sense Codes and Qualifiers 6 Parity Check 6 Recovery Guru Revive Option Is Removed 7 DacStore Script Checks LUN Capacity 7 Limitations in RAID Manager 6 22 1 7 v To Expand DacStore Space on Old LUNs 8 Required Patches 9 FRU Replacement Guide Instructions Incomplete 10 Installing and Uninstalling RAID Manager 6 22 1 11 v To Install RAID Manager 6 22 1 11 Installation Issues 12 Uninstallation Issues 13 Contents iii Upgrading Controller Firmware 13 Upgrading the Solaris Environment With RAID Manager 6 22 1 Already Installed 15 v To Upgrade the Solaris Environment With RAID Manager 6 22 1 Installed 15 Onboard SOC Support for Sun StorEdge A3500FC Array 16 Hardware and Fcode Requirements for Onboard SOC 16 Sun StorEdge Volume Manager and Layered File System Issues 16 Dynamic Multi Pathing and RAID Manager 6 22 1 17 Switching Cables on the Sun StorEdge A3x00 or A3500FC Array With Volume Manager Installed 17 Multiple Paths on the Sun StorEdge A3x00 or A3500FC Array 17 Device Links in dev dsk 18 RAID Manager LUNs Under Volum
13. If you want to enable or disable the DMP feature reference the VERITAS DMP documentation for the correct procedures Refer to the Sun StorEdge Volume Manager 2 6 Release Notes 805 5708 for more information about DMP issues and to the Sun StorEdge Volume Manager 2 6 System Administrator s Guide 805 5706 for instructions on disabling DMP Switching Cables on the Sun StorEdge A3x00 or A3500FC Array With Volume Manager Installed After installing Volume Manager on your host computer do not change the cables between the controllers in a RAID module Caution Switching cables between controllers on your Sun StorEdge A3x00 or A3500FC RAID module can lead to data loss or corruption Multiple Paths on the Sun StorEdge A3x00 or A3500FC Array The vxinstall utility can present multiple paths to the Sun StorEdge A3x00 array If controller failovers occur Volume Manager might see multiple paths to the enclosure and treat them as independent devices This scenario can lead to data loss or corruption To avoid this issue hot_add immediately after installing the Volume Manager packages Chapter 2 Late Breaking Information 17 Device Links in dev dsk Installing some Volume Manager packages such as VRTSvxvm on a host computer with RAID Manager 6 22 1 installed and with LUNs configured causes devlinks to run and both paths to the Sun Storage A3x00 or A3500FC RAID controllers to be listed by the format 1m command Under Fibre Channel con
14. Sun Sun Microsystems the Sun logo AnswerBook2 docs sun com Solaris Sun StorEdge OpenBoot RSM Sun Enterprise SunVTS SunSolve Online SunInstall Sun Enterprise SYMON Ultra et Ultra Enterprise sont des marques de fabrique ou des marques d pos es de Sun Microsystems Inc aux Etats Unis et dans d autres pays Toutes les marques SPARC sont utilis es sous licence et sont des marques de fabrique ou des marques d pos es de SPARC International Inc aux Etats Unis et dans d autres pays Les produits protant les marques SPARC sont bas s sur une architecture d velopp e par Sun Microsystems Inc L interface d utilisation graphique OPEN LOOK et Sun a t d velopp e par Sun Microsystems Inc pour ses utilisateurs et licenci s Sun reconnait les efforts de pionniers de Xerox pour la recherche et le d veloppment du concept des interfaces d utilisation visuelle ou graphique pour l industrie de l informatique Sun d tient une license non exclusive do Xerox sur l interface d utilisation graphique Xerox cette licence couvrant galement les licenci es de Sun qui mettent en place l interface d utilisation graphique OPEN LOOK et qui en outre se conforment aux licences crites de Sun LA DOCUMENTATION EST FOURNIE EN L TAT ET TOUTES AUTRES CONDITIONS DECLARATIONS ET GARANTIES EXPRESSES OU TACITES SONT FORMELLEMENT EXCLUES DANS LA MESURE AUTORISEE PAR LA LOI APPLICABLE Y COMPRIS NOTAMMENT TOUTE GARANTIE IMPLICITE RELATIVE A LA QUAL
15. TAS control creating a LUN or using hot_add could remove the forceload of sd or ssd from the VERITAS section of etc system This would mean that the next reboot of the host would fail You would need to boot from your Solaris CD or network and repair etc system Before you reboot check if the line forceload drv sd is still in the etc systen file Put the forceload line in your etc systen file in front of the RAID Manager 6 section which is labeled BEGIN RAID Manager addition Restore the line forceload drv ssd if your boot device used the ssd driver Upgrading Controller Firmware Caution When upgrading controller firmware make sure that both controllers within a dual controller system have the same firmware level Chapter 2 Late Breaking Information 13 You can use TABLE 2 2 to verify that the firmware level on your controller is supported by your installed version of RAID Manager software Upgrade the controllers to the highest firmware level supported by your current version of RAID Manager Note The array must be in an optimal state for an upgrade If you are upgrading from RAID Manager 6 1 1 Update 2 or a compatible version or if you have any 2 05 xx yy firmware see the Sun StorEdge RAID Manager 6 22 1 Upgrade Guide TABLE 2 2 Supported Controller Firmware Levels Sun StorEdge RAID Manager Version Controller Firmware Appware Level 6 1 2 04 04 01 6 1 1 2 05 02 09 6 1 1 Update 1 2 05 02
16. a Sun Enterprise 4X00 system a Sun Enterprise 5X00 system a Sun Enterprise 6X00 systems m Supported types of I O boards with Onboard SOC a X2611 501 4266 06 I O type 4 83 MHz Gigaplane X2612 501 4883 05 I O type 4 83 90 100 MHz Gigaplane X2622 501 4884 05 I O type 5 83 90 100 MHz Gigaplane a Minimum Fcode requirement for supported I O boards 1 8 25 Sun StorEdge Volume Manager and Layered File System Issues m Switching Cables on the Sun StorEdge A3x00 or A3500FC Array With Volume Manager Installed on page 17 a Multiple Paths on the Sun StorEdge A3x00 or A3500FC Array on page 17 m Device Links in dev dsk on page 18 a RAID Manager LUNs Under Volume Manager on page 18 Root Disk Group and RAID Manager LUNs on page 18 16 Sun StorEdge RAID Manager 6 22 1 Release Notes January 2003 m Warning About VxFS File System Corruption When Running With a Turned Off Array on page 18 a RAID 0 LUN Disk Replacement Warning on page 19 Dynamic Multi Pathing and RAID Manager 6 22 1 The Dynamic Multi Pathing DMP feature in VERITAS Volume Manager 2 x is not compatible with RAID Manager 6 22 1 By default DMP is disabled if you install Volume Manager 2 x after you have installed RAID Manager 6 22 1 If you need to enable this feature for other storage devices you must install Volume Manager 3 0 4 or compatible versions If you are running Volume Manager 2 6 DMP must remain disabled
17. considerably by as much as 50 percent depending on the drive model The same factors that affect the length of time taken to run parityck directly also affect the amount of time required for LUN reconstruction 6 Sun StorEdge RAID Manager 6 22 1 Release Notes January 2003 Recovery Guru Revive Option Is Removed The Recovery Guru no longer allows you to revive drives while a LUN is degraded The potentially dangerous Revive Drive option is not available when you choose the Options gt Manual Recovery gt Drives menu You should only revive drives when a recovery procedure instructs you to do so The drivutil u command allows the same dangerous action to be performed Do not use drivutil u to revive a drive in a degraded LUN as this causes data corruption See bug 4481150 DacStore Script Checks LUN Capacity The new script etc raid bin dacdiscovery allows you to check whether your arrays have old 2 Mbyte DacStore LUNs See the section on LUNs in Limitations in RAID Manager 6 22 1 on page 7 Limitations in RAID Manager 6 22 1 The following are known caveats and issues with the RAID Manager 6 22 1 software a Platforms no longer supported The following platforms are no longer supported in RAID Manager 6 22 1 Sun Ultra 2 workstation SPARCcenter 2000E 2000 and SPARCSserver 1000E 1000 system Sun StorEdge A3500FC array configuration Each Sun StorEdge A3500FC array controller should be on a separate h
18. e Manager 18 Root Disk Group and RAID Manager LUNs 18 Warning About VxFS File System Corruption When Running With a Turned Off Array 18 RAID 0 LUN Disk Replacement Warning 19 Moving Drives Between Sun StorEdge Array Subsystems 19 Dynamic Reconfiguration for Sun StorEdge A3x00 and A3500FCArrays 20 v To Ensure a Module Is Recognized in a Domain Without Reboot 20 Maximum LUN Support in Solaris 2 6 and Higher Environments 21 Guidelines for Creating or Deleting LUNs 23 Creating or Deleting LUNs 23 v To Avoid Problems Creating or Deleting LUNs 23 v To Reset the Factory Default Configuration of the Entire Array 24 v To Create a Default LUNO 24 Resetting the Configuration 24 v To Reset the Array Configuration 25 Removing RAID Modules 25 iv Sun StorEdge RAID Manager 6 22 1 Release Notes January 2003 LUN Segment Size Issues 26 Default Segment Size for RAID Five LUNs 26 Eight Block Segment Size Not Supported in RAID Manager GUI 26 v To Create LUNs With Eight Block Segment Sizes 26 Power Sequencer Local Remote Switch 27 Known Issues 29 Late Breaking Bugs 29 Resolved Bugs Listed by Priority 33 Frequently Asked Questions 37 PATH Update Required After RAID Manager Installation 37 man Page Recognition 38 Screen Refresh in Multiple Module Configurations 38 Host With Sun StorEdge A1000 A3x00 and A3500FC Systems 38 Sun StorEdge A3x00 and A3500FC Support for Dual Hosting and Multi Initiator Configurations 40 Contents v vi Sun Sto
19. e error code ASC ASCQ is 5D 80 RAID Manager 6 used to report PFAs as unit attentions on check conditions and put them on the console log You can ignore the LUN number in all PFA reports Replace the failing drive within 12 hours to avoid having a single point of failure where one drive in a LUN is bad m 4486082 RAID Manager 6 22 Installation On the Boot Device Fails In some cases you can not install the Solaris operating environment or RAID Manager 6 22 and 6 22 1 on the boot device This applies if the boot device is the Sun StorEdge A1000 A3x00 or A3500FC array After installing the operating system and RAID Manager 6 22 x on the new boot device you might get the following error panic cpu0 thread 10404000 vfs_mountroot cannot mount root The error indicates the path for the root device is not set up correctly The workaround is to not boot off the Sun StorEdge A1000 A3x00 or A3500FC array m 4488704 RAID Manager 6 22 1 Build 53 Shows fwutil Failed Messages At Boot Time When the Array Is Not Connected If you reboot the host with RAID Manager 6 22 1 installed and all the Sun StorEdge A1000 and A3x00 arrays are disconnected or powered off the message fwutil failed appears in the log The message indicates the fwutil 1m could not connect to any array It does not indicate any other problem and you can ignore it You can use the arrays when they are powered up m 4488911 Physical Paths Are Seen After Rebooting Or cfgadm
20. en Company Ltd Sun Sun Microsystems the Sun logo AnswerBook2 docs sun com Solaris Sun StorEdge OpenBoot RSM Sun Enterprise Sun VTS SunSolve Online SunInstall Sun Enterprise SYMON Ultra and Ultra Enterprise are trademarks or registered trademarks of Sun Microsystems Inc in the U S and in other countries All SPARC trademarks are used under license and are trademarks or registered trademarks of SPARC International Inc in the U S and in other countries Products bearing SPARC trademarks are based upon an architecture developed by Sun Microsystems Inc The OPEN LOOK and Sun Graphical User Interface was developed by Sun Microsystems Inc for its users and licensees Sun acknowledges the pioneering efforts of Xerox in researching and developing the concept of visual or graphical user interfaces for the computer industry Sun holds a non exclusive license from Xerox to the Xerox Graphical User Interface which license also covers Sun s licensees Wie implement OPEN LOOK GUIs and otherwise comply with Sun s written license agreements U S Government Rights Commercial use Government users are subject to the Sun Microsystems Inc standard license agreement and applicable provisions of the FAR and its supplements DOCUMENTATION IS PROVIDED AS IS AND ALL EXPRESS OR IMPLIED CONDITIONS REPRESENTATIONS AND WARRANTIES INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE OR NON INFRINGEMENT ARE D
21. evice name select Module Profile and look at the Summery Information screen Wait 15 minutes and re run the Recovery Guru to verify that the failure has been fixed If the system reports a battery alert or failure again verify that you reset the battery age on each controller Enable the cache again after you replace the battery Write cache should become active within 12 hours after the battery is fully charged Resolved Bugs Listed by Priority The following is a list of bugs that have been fixed in the 6 22 1 release Priority One m 4405242 Customer lost connectivity to an entire raid module until a controller was removed Priority Two m 4345621 The RAID Manager 6 22 panics on install on s81_15 m 4345987 The RAID Manager 6 22 rdacutil raidutil and drivutil commands return exit status 0 successful completion when invalid arguments are given Chapter 3 Known Issues 33 34 4347418 After executing the usr lib osa bin hot_add command the system could not be rebooted if the boot disks are under VERITAS control 4388578 The firmware 03010300 bwd 03010354 apd and 03010304 bwd 03010360 apd break root boot functionality on the A1000 and A3x00 arrays 4396584 The RAID Manager 6 1 1_Update2 parityck command with correction could mask or exacerbate data corruption 4412025 A Segmentation Fault is displayed with a RAID Manager 6 core dump when used with long WWN s 4453774 The healthck command is continually identi
22. f RAID Manager 6 22 1 as described in Installing and Uninstalling RAID Manager 6 22 1 on page 11 you must install new NVSRAM RAID Manager 6 22 1 contains a new NVSRAM for all Sun StorEdge A1000 A3x00 and A3500FC arrays You must first install RAID Manager 6 22 1 then download the RAID Manager firmware then download the NVSRAM and finally reboot the system The NVSRAM not only fixes some problems but in the case of SCSI arrays ensures reporting of power supply and fan problems You can use the module profile command to make the new NVSRAMs display an Inquiry Product Revision of 0003 TABLE 2 1 lists the new NVSRAM by array type TABLE 2 1 New NVSRAM for Arrays NVSRAM file Array Type 44072dn dl A3500FC RSM tray 44073dn dl A3500FC sie3240c dl A1000 sie3621 dl1 A3000 RSM tray sie3621h dl A3500 4 Sun StorEdge RAID Manager 6 22 1 Release Notes January 2003 v To Install New NVSRAM with the RAID Manager 6 22 1 Upgrade 1 Locate the NVSRAM appropriate for your array s according to TABLE 2 1 The NVSRAM files were put into the usr lib osa fw directory of your system during the RAID Manager installation or upgrade process as part of the SUNWosanv package 2 Launch the Configuration application of RAID Manager etc raid bin rm6 3 Click Maintenance Tuning gt the module name of your array gt Firmware Upgrade Alternately you can click the firmware upgrade button 4 When you see the Important
23. figurations with Solaris 7 and later operating systems sometimes additional device links for the physical devices appear in dev dsk as well These links might have large controller numbers greater than c64 The workaround is to run rdac_disks as soon as the problem appears because it hides the extra controller paths RAID Manager LUNs Under Volume Manager When a RAID Manager LUN is not labeled it might not be recognized as a Volume Manager volume and needs to be labeled If you create a LUN in RAID Manager 6 22 1 and the LUN does not appear to have a label run the format command and label all RAID LUNs Root Disk Group and RAID Manager LUNs Volume Manager volumes configured using devices from the Sun StorEdge A3x00 or A3500FC array subsystem cannot be a part of the root disk group rootdg Configure Sun StorEdge A3x00 or A3500FC array devices to non rootdg disk groups only Warning About VxFS File System Corruption When Running With a Turned Off Array When you turn off a Sun StorEdge A1000 A3x00 or A3500FC array under VERITAS File System VxFS this might eventually result in loss of data in the file system Whenever you turn off an array such as for maintenance ensure that VxFS disables the file systems on that array If VxFS does not disable the file systems automatically you must manually disable them 18 Sun StorEdge RAID Manager 6 22 1 Release Notes January 2003 RAID 0 LUN Disk Replacement Warning According to bug 44651
24. fying unresponsive drives randomly 4470238 The five minute bus reset causes the controller to be offline with RAID Manager 6 22 1 to be offline after three or four hours Priority Three 4241406 Upgrading from RAID Manager 6 1 x fails if Volume Manager is installed on the system 4252937 The RAID Manager 6 22 nvut il command repeats an operation on same device two or three times 4273276 LUN creation can cause repeating error dialogue boxes 4305815 A3000 array PFA Unit Attentions sense data become sd isp fatal errors 4307048 The user cannot boot the D1000 array if RAID Manager 6 is removed and re installed 4324194 RAID Manager 6 CLI controller restore doesn t work as expected 4343416 When the system administrator uses the RAID Manager 6 GUI and healthck command the system does not report controller fan failures 4345328 The fwut il command shows the wrong message for a firmware revision request even though the firmware 3 1 x is installed 4346453 The default rmparams entry for Rdac_HotAddDisabled is wrong for Fibre Channel loops 4365391 RAID Manager 6 1 1 Update2 rmparams is lost when the system is hung or panics 4374861 Unused devinfo nodes under rdnexus waste memory and confuse ownership 4378760 Invoking drivutil p with an unrecognized LUN parameter displays the status or reconstruction progress for LUN 0 instead of the usage information 4392597 ASC ASCQ 3F 0E is unknown and not in raidcode txt 4392601 RAID Manager 6
25. g the Reset Configuration GUI command the dev dsk and dev rdsk paths for the previously existing LUNs are not removed The same is true when using the command line version raidutil X Format 1m then accesses these LUNs and gives errors as described in bug 4339704 listed in the Sun StorEdge RAID Manager 6 22 Release Notes 805 7758 12 These error messages continue until the links are removed or each of the previously existing LUNs is re created 24 Sun StorEdge RAID Manager 6 22 1 Release Notes January 2003 v To Reset the Array Configuration To reset the configuration with the command line CLI interface issue the following commands to controller A usr lib osa bin lad c3t4d0 1771322073 LUNS 0 c8t5d1 1771322005 LUNS 1 rdacutil i c3t4d0 turing72_001 dual active Active controller a c8t5dl units 1 Active controller b c3t4d0 units 0 rdacutil succeeded usr sbin osa raidutil c c8t5d1 X usr lib osa bin lad c3t4d0 1T71322073 LUNS c8t5d0 1T71322005 LUNS 0 6 7 2 4 3 59 3507 of 24 6 Note Device links under dev r dsk of previously existing LUNs are not removed after the configuration is reset Removing RAID Modules Removing an entire RAID module from RAID Manager 6 22 1 does not remove the modules from the Solaris environment The individual LUN device links are not removed when you give the RAID Manager 6 GUI command to Remove the Module If format 1m is cal
26. h to a different module Answer data path to the RAID controllers is initialized when at least one LUN has been created On a system with either no LUN or a first LUN still being formatted the configuration window updates only when the LUN creation has completed This condition affects only the configuration window Normal operation should continue on all other screens Host With Sun StorEdge A1000 A3x00 and A3500FC Systems Question Can I connect a Sun StorEdge A1000 system to a host that has a Sun StorEdge A3x00 and A3500FC system already attached Answer Yes but you must be running RAID Manager 6 1 1 Update 1 or Update 2 or RAID Manager 6 22 and the host must be supported by both Sun StorEdge A1000 and A3x00 and A3500FC platforms 38 Sun StorEdge RAID Manager 6 22 1 Release Notes January 2003 Note Sun StorEdge A1000 array requires support on Solaris 2 5 1 SHWP 4 97 or later The following is a list of platforms currently supported for the Sun StorEdge A1000 A3000 and A3500FC systems at the time this manual was published m Sun StorEdge A1000 array U U U U U U U U U 5 ltra 10 system ltra 30 system Itra Enterprise 250 system Itra Enterprise 450 system Itra Enterprise 3000 system Itra Enterprise 4000 system Itra Enterprise 5000 system Itra Enterprise 6000 system Itra Enterprise 3800 4800 4810 StorEdge A3000 Array Itra Enterprise 250 system Itra Enterprise 450 system Itra E
27. her operating environments you must first complete the RAID Manager upgrade procedure as described in the Sun StorEdge RAID Manager Installation and Support Guide for Solaris 805 7756 or the Sun StorEdge A3500FC Controller Upgrade Guide 806 0479 You can upgrade to a later version of Solaris software with the RAID Manager 6 22 1 software installed that is without uninstalling and reinstalling the RAID Manager software To Upgrade the Solaris Environment With RAID Manager 6 22 1 Installed Save a copy of the kernel drv sd conf file to a safe place You might put the file in a home directory before starting the operating system upgrade procedure After completing the upgrade procedure restore the kernel drv sd conf file If you use the glm driver and you are upgrading from Solaris operating environment 2 5 1 or 2 6 you must modify glm conf See the FIN 10589 Reboot the system Note If you are upgrading to the Solaris 8 operating environment there are several issues to consider See the latest revision of FIN 10685 Chapter 2 Late Breaking Information 15 Onboard SOC Support for Sun StorEdge A3500FC Array Connection of Sun StorEdge A3500FC arrays to onboard SOC interfaces is supported This section discusses the I O boards with onboard SOC that are supported with Sun StorEdge A3500FC array Hardware and Fcode Requirements for Onboard SOC m Supported host platforms a Sun Enterprise 3X00 system
28. icate with the RAID module or view the RAID module through the RAID Manager GUI To work around this issue you can archive and then delete all LUNs over the eight LUN limit prior to moving the RAID modules Sun StorEdge RAID Manager 6 22 1 Release Notes January 2003 Note The more LUNs you have configured the longer reconfiguration boots and add_disks 1m will take Guidelines for Creating or Deleting LUNs This section contains procedures for creating or deleting LUNs on a Sun StorEdge A3x00 and a A3500FC array and guidelines for resetting the configuration on a Sun StorEdge A3x00 array SCSI or a Sun StorEdge A3500FC array Creating or Deleting LUNs Sun StorEdge A1000 A3x00 and A3500FC arrays require the existence of LUN 0 for proper operation While RAID Manager 6 does allow a user to delete LUN 0 its removal causes unpredictable behavior including communication problems through both the GUI and CLI with the array and loss of availability due to random LUN failures To Avoid Problems Creating or Deleting LUNs If a host exhibits delays or an inability to recover from I O faults or rebalance LUNs look for the presence or absence of an optimal LUN 0 On systems without a LUN 0 run RAID Manager 6 to add an optimal LUN 0 to the configuration On systems without disk space available you must architect a workaround to allow for the addition of LUN 0 on a time and materials basis The problem can be avoided by
29. ity than LUNs created before the upgrade even if the drive groups are the same size This condition occurs when the LUNs you create use the maximum available capacity in the drive group Firmware level 2 05 02 or compatible versions requires 40 Mbytes of DacStore disk space per drive whereas earlier versions of firmware 2 04 04 01 or earlier require only 2 Mbytes of DacStore disk space v To Expand DacStore Space on Old LUNs 1 Run the dacdiscovery script in etc raid bin to check whether your arrays have old 2 Mbyte DacStore LUNs 2 Back up the data on existing LUNs that have 2 MByte DacStores 3 Delete existing LUNs 4 Create new LUNs 5 Restore the data previously backed up on the new LUNs a RAID Manager 6 22 1 does not support Solaris operating environment 2 5 1 because that environment is now at end of life m Fibre Channel connections on Sun Enterprise 3x00 servers The use of onboard SOC devices with Sun StorEdge A3500FC array systems is now supported For additional information see Onboard SOC Support for Sun StorEdge A3500FC Array on page 16 a Moving drives between array subsystems Moving drives from one Sun StorEdge A1000 A3x00 or A3500FC array subsystem to another storage array is not supported when the systems are powered off See Moving Drives Between Sun StorEdge Array Subsystems on page 19 for more information 8 Sun StorEdge RAID Manager 6 22 1 Release Notes January 2003 m SunVTS diag
30. led after the command to remove the RAID module messages appear about the module The Array drive has failed a controller on A3000 due to an RDAC open failure of LUN 0 RDAC Failover failed on A3000 LUN O with status 0x5 The workaround is to boot r or delete the LUNs explicitly before removing the module that contains them Chapter 2 Late Breaking Information 25 LUN Segment Size Issues The following sections describe issues that you might encounter when you set or change the segment size of LUNs See the Sun StorEdge RAID Manager User s Guide for information on setting and changing the segment size of individual LUNs in a drive group Default Segment Size for RAID Five LUNs When you create a LUN the default segment size is the optimal size for that RAID level Under Sun StorEdge RAID Manager 6 1 1 including Update 1 and Update 2 the default segment size for RAID 5 LUNs is 32 blocks Under RAID Manager 6 22 1 the default segment size for RAID 5 LUNs has been increased to 64 blocks However you can still select 32 blocks or other segment sizes when creating LUNs In general larger segment sizes might improve performance In RAID Manager 6 22 1 partial I O that is writes to only part of a segment are more efficient than in earlier versions of the software Eight Block Segment Size Not Supported in RAID Manager GUI In earlier versions of Sun StorEdge RAID Manager software eight blocks was the smallest seg
31. m If you are not using a database management system you can also make root the owner of raw partitions and then perform I O at the root level or with a SUID program For more information see bug 4479887 in Chapter 3 Additional Sense Codes and Qualifiers The array controller reports ASC ASCQ combination 0x5d 80 as an AEN that indicates a drive has an excessive soft error rate which suggests the drive might fail Replace the drive within 12 hours to avoid failure Previously the controller reported 0x5d 80 as a unit attention error For a list of ASC ASCQ values that the array controller returns in the sense data refer to the file usr lib osa raidcode txt Parity Check The default parity check setting for the graphical user interface GUI is now set as Report With No Repair When using the CLI you can use the following new options m r reports problems without repairing them It is the default and you should use it when running a manual parity check The reporting function makes sure you do not ignore problems because they will be reported for each run of parityck until you take explicit action to correct the problem a t allows you to investigate potential problems when you combine it with r The option creates a trace file enumerating which blocks had problems that are described on the man page for parityck 1m m R reverses the default by repairing all problems Note The length of time to run parityck can vary
32. ment size allowed for individual LUNs Under RAID Manager 6 22 1 this segment size is not available in the GUI on the Segment Size screen or the Modify Segment Size screen v To Create LUNs With Eight Block Segment Sizes 1 Back up any data stored in the LUN 2 Delete the LUN 3 Use the CLI to create the LUN again and set the segment size as shown in the following example raidutil q c citO0d0 r fast n 0 1 5 z 8 s 34389 g 10 20 11 21 22 amp 26 Sun StorEdge RAID Manager 6 22 1 Release Notes January 2003 4 Reload that data on to the LUN For more information refer to the Sun StorEdge RAID Manager User s Guide Power Sequencer Local Remote Switch The Local Remote switch on each power sequencer is factory set to Remote default This allows power on off control of each power sequencer through the front key switch If the Local Remote switch is set to Local the power on off control of each power sequencer is controlled by each power sequencer s main power circuit breaker switch For further information regarding power sequencer configuration refer to the Sun StorEdge A3500 A3500FC Hardware Configuration Guide Chapter 2 Late Breaking Information 27 28 Sun StorEdge RAID Manager 6 22 1 Release Notes January 2003 CHAPTER 3 Known Issues This chapter contains the latest bugs For a complete list of bugs from earlier versions of RAID Manager refer to the Sun StorEdge RAID Manager 6
33. n 6 22 you must see the Sun StorEdge RAID Manager 6 22 1 Upgrade Guide for more information The chapter covers the following topics Changes in RM 6 22 1 on page 4 Limitations in RAID Manager 6 22 1 on page 7 Required Patches on page 9 Installing and Uninstalling RAID Manager 6 22 1 on page 11 Upgrading the Solaris Environment With RAID Manager 6 22 1 Already Installed on page 15 Onboard SOC Support for Sun StorEdge A3500FC Array on page 16 Sun StorEdge Volume Manager and Layered File System Issues on page 16 Moving Drives Between Sun StorEdge Array Subsystems on page 19 Dynamic Reconfiguration for Sun StorEdge A3x00 and A3500FCArrays on page 20 Maximum LUN Support in Solaris 2 6 and Higher Environments on page 21 Guidelines for Creating or Deleting LUNs on page 23 LUN Segment Size Issues on page 26 Power Sequencer Local Remote Switch on page 27 Changes in RM 6 22 1 Upgrading RAID Manager If you already have RAID Manger 6 installed see the Sun StorEdge RAID Manager 6 22 1 Upgrade Guide The guide provides a checklist to ensure a safe upgrade The procedure is critical if you are upgrading from a version prior to RAID Manager 6 22 During the course of upgrading RAID Manager you must also upgrade the NVSRAM See the following section for more information NVSRAM Installation for Upgrading and Installing RAID Manager During installation o
34. n the etc system file that identify the rdriver as a Dynamic Reconfiguration safe device Dynamic Reconfiguration detach of a system board that contains nonpageable memory might fail to quiesce the operating environment if it is configured with a Sun StorEdge A1000 A3x00 or A3500FC storage array RAID Manager 6 1 1 or 6 22 1 raid controller software and Solaris 2 5 1 or 2 6 operating environment software For additional information and procedures see the Special Handling of Sun StorEdge A3000 section under Chapter 2 in the Sun Enterprise 10000 Dynamic Reconfiguration User Guide 806 2249 for details Maximum LUN Support in Solaris 2 6 and Higher Environments Support for RAID modules that have more than eight LUNs is available in the Solaris 2 6 5 98 and higher releases for SBus and PCI host adapters To support more than eight LUNs you must run one of three possible scripts add16lun sh add32lun sh or the genscsiconf 1 command The add16lun sh script which is available in earlier versions of the RAID Manager software and the add32lun sh script are available on the RAID Manager 6 22 1 CD However you can modify the etc osa rmparams file and run the genscsiconf 1 command for your Sun StorEdge A1000 A3x00 or A3500FC array TABLE 2 3 lists the number of LUNs per RAID module on your Sun StorEdge A3x00 or A3500FC array that are supported for the various combinations of host interfaces host adapters Solaris operating environmen
35. needs to co exist with SYMsm7 on the same host 4402798 The healthck command does not report a power failure if there is no I O to the device 4408321 s8U4_b4 and later failed to show RAID Manager 6 LUNs under format using jumpstart 4418101 How to restart a daemon after changes to rmparams is not clearly documented Sun StorEdge RAID Manager 6 22 1 Release Notes January 2003 4420965 The RAID Manager 6 22 GUI miscalculates the available capacity of drive groups Priority Four 4237586 The pkgrm for RAID Manager 6 22 leaves the rdriver conf file in the kernel drv sparcv9 directory 4332283 RAID Manager 6 reports faults at the Power Supply Unit differently between RAID modules 4382087 The RAID Manager 6 recovery guru procedure for the ESM card replacement is incorrect 4396049 RAID Manager needs a mechanism in the GUI or CLI to display the NVSRAM name or revision 4399135 Write cache mirroring with independent controller configuration is not supported 4432750 The documents should show that parity check and reconstruction times can vary with different disks 4447988 The RAID Manager 6 22 rmparams 4 cluster setting for the Rdac_NoAltOffline entry is TRUE 4468699 rmlogs shows excessive 9501 RAID ASC ASCQ RAID events occurring during normal running Chapter 3 Known Issues 35 36 Sun StorEdge RAID Manager 6 22 1 Release Notes January 2003 CHAPTER 4 Frequently Asked Questions This chapter covers the following iss
36. new batteries New batteries unlike old ones are hot swappable and have LEDs on the front Y To Replace Old Batteries 1 Stop all I O activity to the controller and turn off the power to the RAID module 2 Remove the battery canister and replace it with a new one 3 Record the current date of the installation and the new replacement date on the label The replacement date is two years from the installation date 4 Turn on the power to the RAID module 5 Reset the battery age for each controller device raidutil c device name R If you need information on the device name select Module Profile and look at the Summery Information screen 6 Wait 15 minutes and re run the Recovery Guru to verify that the failure has been fixed If the system reports a battery alert or failure again verify that you reset the battery age on each controller 32 Sun StorEdge RAID Manager 6 22 1 Release Notes January 2003 To Replace New Batteries Turn off the cache and verify the cache LED is off before changing the battery The controller module can still be on because new batteries are hot swappable Remove the battery canister and replace it with a new one Record the current date of the installation and the new replacement date on the label The replacement date is two years from the installation date Reset the battery age for each controller device raidutil c device name R If you need information on the d
37. ng installation and then typing boot r after you install the operating system 12 Sun StorEdge RAID Manager 6 22 1 Release Notes January 2003 ASC ASCQ 5D 80 for a predictive drive failure PFA is normally reported only for the LUN containing the suspect drive and then only once between array reboots This error is now reported as an Asynchronous Event Notification AEN See the section on AEN and SNMP traps on p 70 of the Sun StorEdge RAID Manager 6 22 Installation and Support Guide If no arrays are connected to the host or all of them are powered off during the installation there may be a message in the log saying fwutil failed This is normal and you can ignore it For more information see bug 4488704 in Chapter 3 Uninstallation Issues The kernel drv ap file is not removed during the pkgrm of the RAID Manager 6 packages Installing RAID Manager 6 22 creates file kernel drv ap in order to prevent VERITAS DMP from being enabled inappropriately If the length of kernel drv ap is 0 remove the file so subsequent software installations will work properly Some files are preserved when you remove the RAID Manager 6 packages To completely remove any configuration information so that you can make a completely new installation next time use the command rm rf var osa Files left in var osa which the next installation picks up are mnf rdnexus conf rdriver conf rmlog log and sd conf If your boot disk is under VERI
38. nostic extensions no longer on RAID Manager CD ROM In earlier versions of RAID Manager the diagnostic extensions to the SunVTS product for the Sun StorEdge A1000 were available on the RAID Manager CD as the SUNWvtsse package In RAID Manager 6 22 1 the SUNWvtsse package is no longer available on the RAID Manager CD LUN 0 should not be deleted Do not use the D all option of the raidutil command on Sun StorEdge subsystem arrays The D all option removes all LUNs including the default LUN 0 A LUN 0 must always exist on one controller as a requirement of the SCSI specification For more information about this feature refer to Creating or Deleting LUNs on page 23 For multihost configurations make sure the same Solaris software versions and the same Sun StorEdge RAID Manager software versions are installed on both hosts In addition dual hosting and multi initiator configurations are only supported with Sun Cluster software a The mpxio parameter in the scsi_vhci conf file should not be used to enable multipathing on a system with RAID Manager 6 22 1 Extra physical paths show up in the dev dsk directory See bugs 4488911 4427441 4492343 4493133 in Chapter 3 Required Patches You can get a list of all required patches in Early Notifier 20029 The Early Notifier which is a notice of late breaking changes posted on the Web for customer support provides an overview of the patches necessary to use this product on Solaris e
39. nterprise 3000 system Itra Enterprise 3800 4800 4810 Itra Enterprise 4000 system Itra Enterprise 5000 system Itra Enterprise 6000 system Itra Enterprise 10000 system StorEdge A3500 A3500FC Array Itra Enterprise 250 system Itra Enterprise 450 system Itra Enterprise 3000 3500 system Itra Enterprise 3800 4800 4810 Itra Enterprise 4000 4500 system Itra Enterprise 5000 5500 system Itra Enterprise 6000 6500 system Itra Enterprise 10000 system Chapter 4 Frequently Asked Questions 39 Sun StorEdge A3x00 and A3500FC Support for Dual Hosting and Multi Initiator Configurations Question Are dual hosting and multi initiator configurations supported Answer Dual hosting and multi initiator configurations are only supported with Sun Cluster 2 1 and 2 2 software Sun StorEdge A1000 A3500FC and A3x00 systems are qualified with Sun Cluster software Refer to the Sun Enterprise Hardware Planning and Installation Guide for instructions on cabling your Sun StorEdge A3x00 or A3500FC systems to the nodes and to the Sun Cluster Software Planning and Installation Guide for multi initiator issues For Sun StorEdge A3x00 systems you must update your sd and isp drivers Note This is different from independent controller configurations in which each node owns one of the Sun StorEdge A3x00 or A3500FC controllers and the LUNs on that controller No special software is required for independent controller configurations other than the set
40. nvironment platforms Patches are listed in the order in which they should be installed Installing the Recommended and Security Patch Cluster is a good basis for your environment Caution To avoid the possibility of data corruption you must install all required patches for your configuration You can download the Early Notifier and patches from the SunSolve Online web site http sunsolve sun com Make sure you download the latest revision level for each patch If you have any questions contact your local Sun solution center or Sun service provider for assistance in downloading the patches To use Patch Pro which helps determine which patches your system needs select the Storage Product Patches link from the SunSolve home page or you can use the URL Chapter 2 Late Breaking Information 9 http sunsolve sun com pub cgi show pl target patches patch access Prior to starting the RAID Manager installation or upgrade procedure apply and execute all hardware specific patches disk firmware downloaded system board PROM updated and so on Note Apply the required patches from Early Notifier 20029 and other device driver patches applicable to your operating environment before downloading any RAID controller firmware or executing any hardware patches so that the installation or upgrade is successful 10 FRU Replacement Guide Instructions Incomplete The Sun StorEdge A3x00 Controller FRU Replacement Guide
41. ost bus adapter Check for limitations with your Sun representative regarding Field Information Notice FIN 10586 1 Important No storage device other than the Sun StorEdge A3500FC array should share the same loop with a Sun StorEdge A3500FC array Refer to the Sun StorEdge A3500 A3500FC Hardware Configuration Guide 805 4981 for information on configuring your Sun StorEdge A3500FC array system Bootability with Sun StorEdge A3000 and A3500 Arrays Bootability is now supported The Sun StorEdge RAID Manager 6 22 Installation and Support Guide 805 7756 does not include instructions for installing the software on a RAID Chapter 2 Late Breaking Information 7 module boot device Contact your local Sun solution center or your Sun service provider for information about installing the RAID Manager software on a RAID module boot device See FIN 10619 See also bug 4486082 in Chapter 3 a LUNs created under RAID Manager 6 0 or 6 1 RAID Manager 6 22 and 6 22 1 do not support 2 Mbytes of DacStore When an array is upgraded to 3 x firmware upon the first reboot of the controller the DacStore region is expanded to use the additional 38 Mbyte of the 40 Mbyte reserved area If there is not the additional 38 Mbyte of space the 2 Mbyte DacStore is left intact After upgrading to RAID Manager 6 1 1 or compatible versions you might notice that Sun StorEdge A3x00 LUNs created with firmware level 2 05 02 or compatible versions are smaller in capac
42. performs a system sanity check and then it performs commands to ensure a Sun StorEdge system is recognized by the operating system without requiring a reboot If there are still other SCSI devices in a domain but the last Sun StorEdge A3x00 array has been detached from the domain there might be occasional warning messages in the console window from the array monitoring software These messages are warnings about the inability of the software to communicate with a Sun StorEdge device Note It is good practice to label configurations that is cables RAID modules and so on especially in clustered configurations This helps eliminate confusion when you remove or replace system devices If you must detach a Sun StorEdge device from a large system proper labeling makes it much easier to locate the correct device and also minimizes any chance of mistakes 20 Sun StorEdge RAID Manager 6 22 1 Release Notes January 2003 Before dynamically moving a Sun StorEdge device between domains ensure that at least one LUN is owned by each RAID controller If a Sun StorEdge device is moved to a new domain and hot added to that domain a controller that does not own any LUNs might end up having node names that conflict with other devices on the system If no LUNs exist on a given controller create a small LUN for that controller before performing these types of reconfiguration operations System downtime might be required to add entries i
43. rEdge RAID Manager 6 22 1 Release Notes January 2003 CHAPTER 1 About These Release Notes The Sun StorEdge RAID Manager 6 22 1 Release Notes contain important information about the installation and operation of the Sun StorEdge RAID Manager software that was not available at the time the product documentation was published Read all of these release notes before attempting to install or operate the Sun StorEdge RAID Manager 6 22 1 software on a Sun StorEdge A1000 Sun StorEdge A3000 or Sun StorEdge A3500 and Sun StorEdge A3500FC system Unless the Sun StorEdge A3000 array or Sun StorEdge A3500 array is uniquely identified both systems are referred to as Sun StorEdge A3x00 array throughout this document For late breaking news about the RAID Manager software including required patches and patch revisions the Sun StorEdge A1000 or A3x00 array refer to the Sun StorEdge A1000 and A3x00 Installation Supplement on the Sun documentation web site http docs sun com 2 Sun StorEdge RAID Manager 6 22 1 Release Notes January 2003 CHAPTER 2 Late Breaking Information Much of the information in this chapter consists of late breaking information Some of the topics have appeared in earlier versions of the document and have been updated for this version Other topics have not been updated but they remain in this section due to their importance Note If you are already running a version of RAID Manager earlier tha
44. s by physically reformatting the disk media before the drives are installed Caution Do not migrate data by transferring disks between systems Migrating data might cause the array to become inaccessible the wrong nvsram might be loaded from a foreign disk or ghost drives might appear Data migration is unsupported by RAID Manager 6 Adding a drive to a powered off Sun StorEdge A1000 A3x00 or A3500FC array from another Sun StorEdge A1000 A3x00 or A3500FC array transfers the DacStore information and confuses the controller Phantom drives might be reported Contact your service representative to remove the phantom drives if they are reported Chapter 2 Late Breaking Information 19 Dynamic Reconfiguration for Sun StorEdge A3x00 and A3500FCArrays RAID Manager 6 enables a Sun StorEdge A3x00 or A3500FC array device to be recognized in a new Sun Enterprise E10000 system domain without having to perform a reconfiguration reboot boot r This facility is also included with RAID Manager 6 22 1 v To Ensure a Module Is Recognized in a Domain Without Reboot 1 Install and configure the RAID Manager software in both source and destination domains 2 Attach a Sun StorEdge device that is a new domain 3 Execute the following manual command in the new domain as superuser so that the RAID Manager software recognizes the device without having to reboot the domain usr lib osa bin hot add The hot_add command
45. sS amp o SUN microsystems Sun StorEdge RAID Manager 6 22 1 Release Notes For Sun StorEdge A1000 A3000 A3500 and Sun Microsystems Inc 4150 Network Circle Santa Clara CA 95054 U S A 650 960 1300 Part No 805 7758 14 January 2003 Revision A A3500FC Subsystems Send comments about this document to docfeedback sun com Copyright 2003 Sun Microsystems Inc 4150 Network Circle Santa Clara California 95054 U S A All rights reserved Sun Microsystems Inc has intellectual property rights relating to technology embodied in the product that is described in this document In particnlar and without limitation these intellectual property rights may include one or more of the U S patents listed at ttp www sun com patents and one or more additional patents or pending patent applications in the U S and in other countries This document and the product to which it pertains are distributed under licenses restricting their use copying distribution and decompilation No part of the product or of this document may be reproduced in any form by any means without prior written authorization of Sun and its licensors if any Third party software including font technology is copyrighted and licensed from Sun suppliers Parts of the produet may be derived from Berkeley BSD systems licensed from the University of California UNIX is a registered trademark in the U S and in other countries exclusively licensed through X Op
46. ts and patch levels Chapter 2 Late Breaking Information 21 TABLE 2 3 Maximum Numbers of LUNs Per RAID Module Type of HBA Solaris Operating Number Interface Part Number Environment Required Patch if any Patch Description of LUNs SCSI SBus X1065A none none PCI X6541A 2 6 5 98 105580 13 or compatible glm device driver patch for PCI revision level t 7 8 99 106925 05 or compatible glm device driver patch for PCI revision level FC SBus 2 6 5 98 105375 17 or compatible sf and socal device drivers X6730A revision level t patch 7 8 99 PCI X6729A 2 6 5 98 107469 04 or compatible revision level none 107280 04 or compatible revision level sf and socal device drivers patch ifp device driver patch 32 7 8 99 107292 03 or compatible ifp device driver patch 16 revision level 8 none Contact your local Sun solution center or service provider to get the latest patch revision level and information about 32 LUN support 22 Note For best results configure all 32 LUNs on your RAID modules if you make changes to support 32 LUNS If you do not configure all the LUNs you might notice system delays when you boot SCSI systems If you are moving RAID modules with more than eight LUNs configured to a host system that does not support more than eight LUNs for example a host system running the Solaris 2 5 1 environment you will not be able to commun
47. ues m SPATH Update Required After RAID Manager Installation on page 37 m man Page Recognition on page 38 m Screen Refresh in Multiple Module Configurations on page 38 a Host With Sun StorEdge A1000 A3x00 and A3500FC Systems on page 38 m Sun StorEdge A3x00 and A3500FC Support for Dual Hosting and Multi Initiator Configurations on page 40 For additional listings of frequently asked questions refer to the Sun StorEdge RAID Manager Installation and Support Guide for Solaris and the Sun StorEdge RAID Manager User s Guide SPATH Update Required After RAID Manager Installation Question What environment variables do I need to update after installing the RAID Manager software Answer You must include the following location in your PATH environment variable to enable command line access to the various tools and utilities etc raid bin 37 man Page Recognition Question I have installed the SUNWosamn package yet I cannot get the man command to reference any StorEdge RAID Manager utilities What should I do Answer To have the man pages recognized on your system the man page indexes must be rebuilt after the SUNWosamn package has been installed To do this run the catman Im utility as follows catman w Screen Refresh in Multiple Module Configurations Question In a multiple RAID module configuration why doesn t the first configuration window refresh when I switc
48. up through RAID Manager 40 Sun StorEdge RAID Manager 6 22 1 Release Notes January 2003
49. user access by that user causes error messages Further failover does not occur properly in all cases on these partitions Databases or data base logs are sometimes configured on top of raw RAID Manager 6 disk partitions RAID Manager 6 22 1 and RAID Manager 6 22 with patch 108853 03 or 108834 03 closed a security hole as described in bug 4336484 It is possible to get permission denied messages or log message about access failures You might see a message saying I O to invalid geometry when a non root user opens a raw partition Other messages might be about failover attempts but failover does not actually occur See Non root Access to Raw Partitions on page 5 30 Sun StorEdge RAID Manager 6 22 1 Release Notes January 2003 m 4480763 RAID Manager 6 22 1 GUI Shows Garbage With the Controller Mode Option With the Sun StorEdge A1000 Array When a system has only a Sun StorEdge A1000 array installed the Maintenance application does not label the display column properly This is only cosmetic Under maintenance select All RAID Modules for RAID Module and select Options gt Controller mode You see RAID Module Controller A y eA1000 Active No Controller You should see Controller B instead of seeing y e m 4485449 RAID Manager Does Not Correctly Report LUN Numbers With PFAs Because RAID Manager 6 22 1 reports predicted drive failure alerts PFAs are reported in rmlog as AENs there is no LUN information Th