Home
Sun Datacenter InfiniBand Switch 36 Command Reference
Contents
1. 1X or 4X LinkWidthActive 4X LinkSpeedSupported 2 5 Gbps or 5 0 Gbps or 10 0 Gbps LinkSpeedEnabled 2 5 Gbps or 5 0 Gbps or 10 0 Gbps LinkSpeedActive 4 2 5 Gbps After PortInfo set Port info DR path slid 65535 dlid 65535 0 port 7 j Related Information m enableswitchport Command on page 22 m ibportstate Command on page 99 m getportstatus Command on page 31 m Linux Shells for Hardware Commands on page 3 Understanding Hardware Commands 19 enablecablelog Command Enables logging of cable events Syntax enablecablelog Description This hardware command enables logging of cable events to the Syslog The enablecablelog command is available from the SYS Fabric_Mgmt Linux shell target of the Oracle ILOM CLI interface Example The following example shows how to enable logging of cable events to the Syslog with the enablecablelog command enablecablelog Stopping Environment daemon OK Starting Environment daemon OK Related Information m disablecablelog Command on page 15 m enablelinklog Command on page 20 m Linux Shells for Hardware Commands on page 3 enablelinklog Command Enables logging of link events 20 Sun Datacenter InfiniBand Switch 36 Command Reference April 2011 Syntax enablelinklog Description This hardware command enables log
2. 1X or 4X LINKWidthActiVe o ooooooooooo 4X LinkSpeedSupported 2 5 Gbps or 5 0 Gbps or 10 0 Gbps LinkSpeedEnabled 2 5 Gbps or 5 0 Gbps or 10 0 Gbps LinkSpeedActiVe oooooooooooo 10 0 Gbps Related Information ibportstate man page m disableswitchport Command on page 18 m enablesm Command on page 21 m ibdevreset Command on page 34 m listlinkup Command on page 35 m Linux Shells for InfiniBand Commands on page 59 ibroute Command Queries InfiniBand switch forwarding tables Understanding InfiniBand Commands 101 Syntax ibroute d a n D e G h M s smlid v V C ca_name P ca_port t timeout lid dr_path guid startlid endlid 1 where smlid is the Subnet Manager LID ca_name is the channel adapter name ca_port is the channel adapter port timeout is the timeout in milliseconds lid is the local identifier dr_path is the directed path guid is the global unique identifier startlid is the starting local identifier endlid is the ending local identifier Description This InfiniBand command uses SMPs to display the forwarding tables for the specified switch LID and optionally the LID range By default the range is all valid entries from 1 to FDBTop The ibroute command is available from the SYS Switch_Diag and SYS Fabric_Mgmt Linux shell targets of the Oracle ILOM CLI interface Options
3. G generatetopology command 27 getfanspeed command 28 getmaster command 29 getnm2type command 30 getportstatus command 31 H hardware commands 1 help command 32 l ibaddr command 60 ibcheckerrors command 62 ibchecknet command 64 ibchecknode command 66 ibcheckport command 67 ibcheckportstate command 69 ibcheckportwidth command 71 ibcheckstate command 72 ibcheckwidth command 74 ibclearcounters command 76 ibclearerrors command 77 ibdatacounters command 79 ibdatacounts command 80 ibdevreset command 34 ibdiagnet command 82 support files 83 ibdiagpath command 87 support files 87 ibhosts command 90 ibnetdiscover command 92 topology file 92 ibnetstatus command 95 ibnodes command 97 ibportstate command 99 ibroute command 101 ibrouters command 104 ibstat command 105 ibstatus command 107 ibswitches command 109 ibsysstat command 110 ibtracert command 112 InfiniBand commands 57 L listlinkup command 35 M managementreset command 36 matchtopology command 37 O object identifiers 127 P perfquery command 114 S saquery command 117 168 Sun Datacenter InfiniBand Switch 36 Command Reference April 2011 setcontrolledhandover command 38 setloghost command 40 setmsmlocationmonitor command 41 setsmpriority command 42 setsubnetprefix command 44 showfruinfo command 45 showpsufru command 46 showsmlog command 47 showtemps command 49 showtopology command
4. There is no authentication or privacy a authNoPriv There is authentication but no privacy a authPriv There is authentication and privacy m authentication_protocol is either MD5 or SHA m authentication_password is the snmp_user s authentication password m privacy_password is the snmp_user s privacy password m mc_IP is the IP address of the management controller m object_id is the object identifier as listed in the right column of the tables m argument is a combination of options and variables that support the object identifier For example to securely display the version of the MIB on the management controller with IP address of 123 45 67 89 snmpget v3 u usersnmp 1 authPriv a MD5 A authpass x DES X privpass 123 45 67 89 SUN DCS MIB mibVersion Related Information m SUN ILOM CONTROL MIB MIB OID Command Syntax on page 143 m SUN PLATFORM MIB MIB OID Command Syntax on page 153 Understanding SNMP MIB OIDs 129 a ENTITY MIB MIB OID Command Syntax on page 164 Enclosure OIDs The following table lists enclosure object identifiers supported by the SUN DCS MIB MIB Description of Task or Activity Action MIB OID Display the MIB version read mibVersion Display the type of platform Sun DCS 36p and read plat formName so on Display the service processor firmware version read spFwVersion Display the FRGA CPLD firmware version read fpgaVersion Related Information
5. This software or hardware and documentation may provide access to or information on content products and services from third parties Oracle Corporation and its affiliates are not responsible for and expressly disclaim all warranties of any kind with respect to third party content products and services Oracle Corporation and its affiliates will not be responsible for any loss costs or damages incurred due to your access to or use of third party content products or services Copyright 2009 2011 Oracle et ou ses affili s Tous droits r serv s Ce logiciel et la documentation qui Laccompaghe sont pee par les lois sur la propri t intellectuelle Ils sont conc d s sous licence et soumis des restrictions d utilisation et de divulgation Sauf disposition de votre contrat de licence ou de la loi vous ne pouvez pas copier reproduire traduire diffuser modifier breveter transmettre distribuer exposer ex cuter publier ou afficher le logiciel m me partiellement sous quelque forme et par uelque proc d que ce soit Par ailleurs il est interdit de proc der a toute ing nierie inverse du logiciel de le d sassembler ou de le d compiler except a es fins d interop rabilit avec des logiciels tiers ou tel que prescrit par la loi Les informations fournies dans ce document sont susceptibles de modification sans pr avis Par ailleurs Oracle Corporation ne garantit pas qu elles soient exemptes d erreurs et vous in
6. m OID Tables Overview on page 127 m SUN DCS MIB MIB OID Command Syntax on page 129 Enclosure Nodes OIDs The following table lists enclosure node object identifiers supported by the SUN DCS MIB MIB Description of Task or Activity Action MIB OID Display a table of information about the read ibEncNodesTable InfiniBand nodes belonging to the enclosure Display a row of the ibEncNodesTable read ibEncNodesEntry Display an index of InfiniBand nodes belonging read ibEncNodesIndex to the enclosure Display the type of InfiniBand node switch CA read ibEncNodesType and so on Display the GUID of the node read ibEncNodesGuid Display the number of ports of the node read ibEncNodesPorts Display the NodeDescription of the node read ibEncNodesDescr Display the LID of the node read ibEncNodesLid 130 Sun Datacenter InfiniBand Switch 36 Command Reference April 2011 Description of Task or Activity Action MIB OID Display the firmware version of the node read ibEncNodesFwVersion Display the board or FRU on which the read ibEncNodesBoard InfiniBand node is located Display additional identification information of read ibEncNodesName the InfiniBand node Related Information a OID Tables Overview on page 127 m SUN DCS MIB MIB OID Command Syntax on page 129 Neighbor Node OIDs The following table lists neighbor node object identifiers supported by the S
7. Display or set the host name for Oracle ILOM read ilomCtrlHostName write Related Information m OID Tables Overview on page 127 m SUN ILOM CONTROL MIB MIB OID Command Syntax on page 143 SMTP OIDs The following table lists SMTP object identifiers supported by the SUN ILOM CONTROL MIB MIB Description of Task or Activity Action MIB OID Display or set whether or not the SMTP client is read ilomCtr1SMTPEnabled enabled write Display or set the IP address of the SMTP server read ilomCtr1SMTPServerIP used as a name service for user accounts write Display or set the port number for the SMTP read ilomCtr1SMTPPortNumber client write Display or set an optional format to identify the read ilomCtr1SMTPCustomSender sender or the from address write Related Information m OID Tables Overview on page 127 m SUN ILOM CONTROL MIB MIB OID Command Syntax on page 143 152 Sun Datacenter InfiniBand Switch 36 Command Reference April 2011 Understanding the SUN PLATFORM MIB MIB OIDs This topic provides tables of the hardware sensor alarms and watchdog object identifiers Tables of object identifiers are provided in the following topics m SUN PLATFORM MIB MIB OID Command Syntax on page 153 m Understanding MIB Physical OIDs on page a MIB Trap OIDs on page 162 Related Information a OID Tables Overview on page 127 154 m Understanding the SUN DCS MIB MIB OIDs on page 128 m SUN HW
8. ibnetdiscover Command on page 92 m ibnodes Command on page 97 m Linux Shells for InfiniBand Commands on page 59 ibstat Command Queries basic status of InfiniBand devices Syntax ibstat d e h 1 s p V ca_name ca_port where m ca_name is the channel adapter name m ca_port is the channel adapter port Understanding InfiniBand Commands 105 Description This InfiniBand software command displays basic information retrieved from the local InfiniBand driver Output of the command includes m LID m SMLID m port logical state m link width m port physical state The ibstat command is similar to the ibstatus command however the ibstat command is a binary executable has options to display channel adapters and ports and provides more information than the ibstatus command The ibstat command is available from the SYS Switch_Diag and SYS Fabric_Mgmt Linux shell targets of the Oracle ILOM CLI interface Options The following table describes the options to the ibstat command and their purposes Option Purpose d Sets the debug level Can be used several times to increase the debug level e Displays send and receive errors h Provides help 1 Lists all InfiniBand devices s Provides short output p Shows port list V Displays the version information 106 Sun Datacenter InfiniBand Switch 36 Command Reference April 2011 Example The following example
9. Display the performance counter causing a trap read ibSnmpTrapPerfErrCounter Display the counter value causing a trap read ibSnmpTrapCounterVal Display a mapping of SNMP InfiniBand device read ibSnmpTrapPortConnector port to connector causing a trap Identify the master Subnet Manager causinga read ibSnmpTrapMasterSMPresent trap Display the LID of the master Subnet Manager read ibSnmpTrapMasterSMLid of a trap Display the currently active link width of a trap read ibSnmpTrapLinkWidthActive Display the state of the link on the port of a trap read ibSnmpTrapLinkState Display the currently active link speed of a trap read ibSnmpTrapLinkSpeedActive Display the GUID of the trap s node read ibSnmpTrapNodeGuid Display the LID of the trap s node read ibSnmpTrapNodeLid Display the NodeDescription of the trap s read ibSnmpTrapNodeDescr node Display how much the symbol error counter read ibSnmpSymErrIncrease increased during the error rate monitoring interval Display and set the error rate monitoring read ibSnmpErrRateInterval interval write A performance error counter threshold was ibSnmpPer fErrCounterTrap exceeded Node port counter and its value are passed inside the trap 140 Sun Datacenter InfiniBand Switch 36 Command Reference April 2011 Description of Task or Activity Action MIB OID This trap is sent when a change happens in master Subnet Manager presence ibSnmpNoMasterSMTrap This trap is s
10. For example using the V2c protocol command v2c c public mc_IP ENTITY MIB object_id argument Or using the V3 protocol command v3 u snmp_user 1 security_level a authentication_protocol A authentication_passwor x DES X privacy_password mc_IP ENTITY MIB object_id argument where a command is the command of the SNMP client that performs the action m snmp_user is a configured user of the SNMP services m security_level is noAuthNoPriv There is no authentication or privacy a authNoPriv There is authentication but no privacy authPriv There is authentication and privacy m authentication_protocol is either MD5 or SHA m authentication_password is the snmp_user s authentication password m privacy_password is the snmp_user s privacy password a mc_IP is the IP address of the management controller m object_id is the object identifier as listed in the right column of the tables m argument is a combination of options and variables that support the object identifier For example to securely display the discription of physical entity 4 on the management controller with IP address of 123 45 67 89 snmpget v3 u usersnmp 1 authPriv a MD5 A authpass x DES X privpass 123 45 67 89 ENTITY MIB entPhysicalDescr 4 Related Information m SUN DCS MIB MIB OID Command Syntax on page 129 m SUN ILOM CONTROL MIB MIB OID Command Syntax on page 143 m SU
11. Sun Platform Alarm Table OIDs 161 MIB Trap OIDs 162 Understanding the ENTITY MIB MIB OIDs 163 ENTITY MIB MIB OID Command Syntax 164 Physical Entity Table OIDs 165 Index 167 xvi Sun Datacenter InfiniBand Switch 36 Command Reference April 2011 Using This Documentation This command reference provides detailed information regarding the commands to administer the Sun Datacenter InfiniBand Switch 36 from Oracle This document is written for developers system administrators and users who have advanced experience administering InfiniBand fabrics and hardware m Related Documentation on page xvii m Documentation Support and Training on page xviii Related Documentation The documents listed as online are available at http www oracle com pls topic lookup ctx E19197 01 amp id homepage Application Title Format Location Getting started Sun Datacenter InfiniBand Switch 36 Getting Printed Shipping Started Guide PDE kit Online Last minute Sun Datacenter InfiniBand Switch 36 Product PDF Online information Notes Installation Sun Datacenter InfiniBand Switch 36 User s PDF Online administration Guide HTML and service xvii Application Title Format Location Command Sun Datacenter InfiniBand Switch 36 Command PDF Online reference Reference HTML Compliance Sun Datacenter InfiniBand Switch 36 Safety and PDF Online Compliance Guide Oracle ILOM Oracle Integrated Lights Out
12. ibnetdiscover Command on page 92 m ibnodes Command on page 97 m Linux Shells for InfiniBand Commands on page 59 ibsysstat Command Displays system status of an InfiniBand address Syntax ibsysstat d e G h s smlid v V C ca_name P ca_port t timeout o oui S lid guid op where a smlid is the Subnet Manager LID m topology is the topology file m ca_name is the channel adapter name m ca_port is the channel adapter port m timeout is the timeout in milliseconds m oui is the OUI number 110 Sun Datacenter InfiniBand Switch 36 Command Reference April 2011 m lid is the local identifier m guid is the global unique identifier m op is the operation to perform on the node a ping Verify connectivity to the server a host Obtain host information from the server cpu Obtain CPU information from the server Description This InfiniBand command uses vendor supplied management datagrams to validate connectivity between InfiniBand nodes and return other information about the node The command is a client server in that a remote node is configured as a server while a local node performs as a client The command is first run locally on the server The command is then run again locally on the client pointing to the LID of the server The ping repeats every second on the server until you type the Ctrl C key combination to exit the command Options The following
13. on page 127 m Understanding the SUN DCS MIB MIB OIDs on page 128 m SUN HW TRAP MIB MIB OIDs on page 141 m Understanding the SUN PLATFORM MIB MIB OIDs on page 153 m Understanding the ENTITY MIB MIB OIDs on page 163 SUN ILOM CONTROL MIB MIB OID Command Syntax When you use the object identifiers in a command syntax you must include the SUN ILOM CONTROL MIB MIB name For example using the V2c protocol command v2c c public mc_IP SUN ILOM CONTROL MIB object_id argument Or using the V3 protocol command v3 u snmp_user 1 security_level a authentication_protocol A authentication_password x DI ES X privacy_password mc_IP SUN ILOM CONTROL MIB object_id argument where command is the command of the SNMP client that performs the action m snmp_user is a configured user of the SNMP services m security_level is a noAuthNoPriv There is no authentication or privacy a authNoPriv There is authentication but no privacy a authPriv There is authentication and privacy m authentication_protocol is either MD5 or SHA m authentication_password is the snmp_user s authentication password m privacy_password is the snmp_user s privacy password m mc_IP is the IP address of the management controller m object_id is the object identifier as listed in the right column of the tables Understanding SNMP MIB OIDs 143 m argument is a combination of options and varia
14. purposes Option Purpose L Does not output to syslog h Provides help Example The following example shows how to test the Subnet Manager configuration with the smconfigtest command smconfigtest Related Information m getmaster Command on page 29 m Linux Shells for Hardware Commands on page 3 version Command Hardware Displays switch version Syntax version Description This hardware command shows the hardware and software versions and date information for the switch and management controller Understanding Hardware Commands 55 56 The version command is available from the SYS Switch_Diag and SYS Fabric_Mgmt Linux shell targets of the Oracle ILOM CLI interface Example The following example shows how to display the version information with the version command version SUN DCS 36p version 1 3 0 1 Build time Aug 17 2010 14 36 41 SP board info Manufacturing Date 2010 01 22 Serial Number NCD4J0165 Hardware Revision 0x0100 Firmware Revision 0x0102 BIOS version NOW1R112 BIOS date 04 24 2009 Related Information m Switch Service display switch chip firmware version m Linux Shells for Hardware Commands on page 3 Sun Datacenter InfiniBand Switch 36 Command Reference April 2011 Understanding InfiniBand Commands The InfiniBand commands act upon or monitor many aspects of the InfiniBand fabric A portion of the comman
15. write Display or set the IP address of the second read ilomCtrlRemoteSyslogDest2 remote syslog destination log host write Related Information a OID Tables Overview on page 127 m SUN ILOM CONTROL MIB MIB OID Command Syntax on page 143 HTTP OIDs The following table lists HTTP service object identifiers supported by the SUN ILOM CONTROL MIB MIB Description of Task or Activity Action MIB OID Display or set whether or not the embedded web read server is running and listening on the HTTP port write ilomCtrlHttpEnabled Display or set the port number that the read embedded web server should listen to for HTTP write requests Display or set whether or not the embedded web read server should redirect HTTP connections to write HTTPS ilomCtrlHttpPortNumber ilomCtrlHttpSecureRedirect Related Information a OID Tables Overview on page 127 m SUN ILOM CONTROL MIB MIB OID Command Syntax on page 143 Understanding SNMP MIB OIDs 145 HTTPS OIDs The following table lists HTTPS service object identifiers supported by the SUN ILOM CONTROL MIB MIB Description of Task or Activity Action MIB OID Display or set whether or not the embedded web read ilomctrlHttpsEnabled server is running and listening on the HTTPS write port Display or set the port number that the read ilomCtr1lHttpsPortNumber embedded web server should listen to for
16. 124 Description 124 Options 125 Example 126 Understanding SNMP MIB OIDs 127 OID Tables Overview 127 Understanding the SUN DCS MIB MIB OIDs 128 SUN DCS MIB MIB OID Command Syntax 129 Enclosure OIDs 130 Enclosure Nodes OIDs 130 Neighbor Node OIDs 131 Subnet Manager Info OIDs 132 Subnet Manager Agent Data Port OIDs 132 Understanding Performance Manager Agent OIDs 134 PMA Port Counters Table OIDs 135 PMA Extended Port Counters Table OIDs 136 Understanding SNMP Trap OIDs 137 Trap Control OIDs 138 Trap Threshold OIDs 138 Trap Notification OIDs 140 SUN HW TRAP MIB MIB OIDs 141 Understanding the SUN ILOM CONTROL MIB MIB OIDs 142 SUN ILOM CONTROL MIB MIB OID Command Syntax 143 NTP OIDs 144 Remote Syslog OIDs 145 HTTP OIDs 145 Contents xv HTTPS OIDs 146 Network OIDs 146 User OIDs 148 Session OIDs 148 Event Log OIDs 149 Alert OIDs 150 Clock OIDs 151 Backup and Restore OIDs 151 Identification OIDs 152 SMTP OIDs 152 Understanding the SUN PLATFORM MIB MIB OIDs 153 SUN PLATFORM MIB MIB OID Command Syntax 153 Understanding MIB Physical OIDs 154 High Level OIDs 155 NIM Equipment Table OIDs 155 Physical Class Extension Table OIDs 156 Sun Platform Sensor Table OIDs 157 Sun Platform Binary Sensor Table OIDs 157 Sun Platform Numeric Sensor Table OIDs 158 Discrete Sensor Table OIDs 160 Discrete Sensor States Table OIDs 160 Sun Platform Fan Table OIDs 161
17. 127 m SUN PLATFORM MIB MIB OID Command Syntax on page 153 Discrete Sensor States Table OIDs The following table lists discrete sensor state object identifiers supported by the SUN PLATFORM MIB MIB Description of Task or Activity Action MIB OID Display a table of available states fora read sunPlatDiscreteSensorStatesTable discrete sensor of the Discrete Sensor Table Display information about a sensor read sunPlatDiscreteSensorStatesEntry state for a sensor in the Discrete Sensor Table Display a number identifying the read sunPlatDiscreteSensorStatesIndex sensor state Display an interpretation of a discrete read sunPlatDiscreteSensorStatesInterpretation sensor state Display or set whether the state value is read sunPlatDiscreteSensorStatesAcceptable acceptable Related Information m OID Tables Overview on page 127 m SUN PLATFORM MIB MIB OID Command Syntax on page 153 160 Sun Datacenter InfiniBand Switch 36 Command Reference April 2011 Sun Platform Fan Table OIDs The following table lists fan object identifiers supported by the SUN PLATFORM MIB MIB Description of Task or Activity Action MIB OID Display a table of attributes common to all fans read sunPlatFanTable and cooling devices Display information about a piece of equipment read sunPlatFanEntry with an entPhysicalClass of fan 7 Display the class of the cooling device read sunPlatFanClass Related
18. 14 29 37 CEST 2010 Related Information m generatetopology Command on page 27 m matchtopology Command on page 37 m Linux Shells for Hardware Commands on page 3 showunhealthy Command Displays problematic components Syntax showunhealthy Description This hardware command shows a list of switch components that appear to have a problem Unlike the env_test command the showunhealty command only displays messages for components that have failed testing The showunhealthy command is available from the SYS Switch_Diag and SYS Fabric_Mgmt Linux shell targets of the Oracle ILOM CLI interface Understanding Hardware Commands 53 Example The following example shows how to display a list of unhealthy components in the switch with the showunhealthy command showunhealthy OK No unhealthy sensors Related Information m env_test Command on page 24 m Linux Shells for Hardware Commands on page 3 smconfigtest Command Tests Subnet Manager configuration Syntax smconfigtest 1 h Description This hardware command tests the Subnet Manager configuration and reports if it is corrupt The smconfigtest command is available from the SYS Fabric_Mgmt Linux shell target of the Oracle ILOM CLI interface 54 Sun Datacenter InfiniBand Switch 36 Command Reference April 2011 Options The following table describes the options to the smconfigtest command and their
19. Commands The hardware commands act upon or monitor the switch hardware They are available through the Oracle ILOM CLI interface with the SYS Fabric_Mgmt target A smaller subset of commands are available for monitoring purposes with the SYS Switch_Diag target See Linux Shells for Hardware Commands on page 3 With the standard Linux shell CLI interface only the root user of the management controller can run all of the hardware commands The format of the hardware commands is as follows command arguments arguments Command Syntax Links chassis_led on off green yellow white chassis_led Command on page 5 checkboot checkboot Command on page 6 checkguidfilesftree h q v checkguidfilesftree Command on page 7 checkpower checkpower Command on page 8 checktopomax h 1 v checktopomax Command on page 9 checkvoltages checkvoltages Command on page 11 connector name present portstate info dump h connector Command on page 12 desport port port connector connector dcsport Command on page 14 printconnectors disablecablelog disablecablelog Command on page 15 disablelinklog disablelinklog Command on page 16 disablesm disablesm Command on page 17 disableswitchport reason reason connector disableswitchport Command on page 18 Switch port enablecablelog enablecablelog Command on page 20 enablelinklog
20. HTTPS write requests Related Information a OID Tables Overview on page 127 m SUN ILOM CONTROL MIB MIB OID Command Syntax on page 143 Network OIDs The following table lists network object identifiers supported by the SUN ILOM CONTROL MIB MIB Description of Task or Activity Action MIB OID Display a table of targets whose networks canbe read ilomCtr1lNetworkTable controlled Display information about a target which canbe read ilomCtr1NetworkEntry reset Display the nomenclature name for a target read ilomCtr1lNetworkTarget which has a configurable network Display the MAC address of the service read ilomCtr1NetworkMacAddress processor or system controller Display whether the current target is configured read ilomCtr1lNetworkIpDiscovery to have static IP settings or whether these settings are retrieved dynamically from DHCP Display the current IP address for the given read ilomCtr1lNetworkIpAddress target Display the current IP gateway for the given read ilomCtr1lNetworkIpGateway target 146 Sun Datacenter InfiniBand Switch 36 Command Reference April 2011 Description of Task or Activity Action MIB OID Display the current IP netmask for the given read ilomCtr1NetworkIpNetmask target Display or set the pending value for the mode of read ilomCtr1NetworkPendingIpDiscovery IP discovery for the given target write Display or set the pending IP address for the read ilomCtr1NetworkPendingIp
21. Linux Shells for InfiniBand Commands on page 59 ibportstate Command Manages the state and link speed of an InfiniBand port Syntax ibportstate d D e G h s smlid v C ca_name P ca_port t timeout lid dr_path guid port op where smlid is the Subnet Manager LID topology is the topology file ca_name is the channel adapter name ca_port is the channel adapter port timeout is the timeout in milliseconds lid is the local identifier dr_path is the directed path guid is the global unique identifier port is the port being validated op is the operation to perform on the port enable disable reset speed number where number is 1 for SDR 2 for DDR and 4 for QDR query default Understanding InfiniBand Commands 99 Description This InfiniBand command queries the logical and physical state of an InfiniBand port The command can return the link width and speed of a switch port as well as enabling disabling or resetting the port The command can also set the link speed of any InfiniBand port Note Speed changes are not affected until the port undergoes link renegotiation Additionally speed values are additive for enabling For example speed 7 is 2 5 5 0 and 10 0 Gbyte sec The ibportstate command is available from the SYS Switch_Diag and SYS Fabric_Mgmt Linux shell targets of the Oracle ILOM CLI interface Options The following table describes the
22. Note The output for your InfiniBand fabric will differ from that in the example ibnetstatus Loading IBDIAGNET from usr lib ibdiagnet1 2 W Topology file is not specified Reports regarding cluster links will use direct routes Loading IBDM from usr lib ibdm1 2 I Using port 0 as the local port I Discovering 9 nodes 2 Switches amp 7 CA s discovered ts I St an atte E tk ell nr Sa pce id a a sp San sine SS Si a a dl a eh Nes a Sa Va I Bad Guids LIDs Info ae I a PR A A S a a A E AA a E E E e A a a a gy N I skip option set no report will be issued pam I ES A A A a A A RO ME E A A E S N I Links With Logical State INIT pea I A a E ae e II A ah A A NA E eee i I No bad Links with logical state INIT were found se E a A A A A E E E A O A E O A A A I PM Counters Info rey TI Ea NI ON A A A E A AN AN AN RN eer W 1id 0x0010 guid 0x00212856cfe2c0a0 dev 48438 Port 1 Performance Monitor counter Value symbol_error_counter Oxffff overflow W 1id 0x0010 guid 0x00212856cfe2c0a0 dev 48438 Port 2 Performance Monitor counter Value symbol_error_counter Oxffff overflow W 1id 0x0010 guid 0x00212856cfe2c0a0 dev 48438 Port 3 Performance Monitor counter Value symbol_error_counter Oxffff overflow W 1id 0x0010 guid 0x00212856cfe2c0a0 dev 48438 Port 4 Performance Monitor counter Value symbol_error_counter Oxffff overflow T a a A AS
23. Sept8 topo The following is a portion of a topology file created by the generatetopology command Understanding Hardware Commands 27 Note Your topology file will differ DEV26418_02P nsn34 45_HCA 1 P1 4x 10G gt SUNDCS36QDR nsn34 170 C 0A P2 4x 10G gt SUNDCS36QDR nsn34 170 C OB SUNDCS360DR nsn34 170 P1 4x 10G gt SUNIBQDRGW nsn34 97 C 7A P2 4x 10G gt I4_ GENERIC nsn34 98 P33 SUNIBODRGW nsn34 97 C 17A 4x 10G gt SUNDCS36QDR nsn34 170 C 17B C 17B 4x 10G gt SUNDCS360DR nsn34 170 C 17A C 16A 4x 10G gt SUNDCS36QDR nsn34 170 C 16B C 16B 4x 10G gt SUNDCS36QDR nsn34 170 C 16A C 15A 4x 10G gt SUNDCS36QDR nsn34 170 C 15B C 15B 4x 10G gt SUNDCS36QDR nsn34 170 C 15A C 14A 4x 10G gt SUNDCS36QDR nsn34 170 C 13A C 14B 4x 10G gt SUNDCS36QDR nsn34 170 C 8A DEV26418_02P nsn34 39_HCA 1 P1 4x 10G gt SUNDCS36QDR nsn34 170 C 12A P2 4x 10G gt SUNDCS36QDR nsn34 170 C 13B Created from nsn34 170 at Wed Sep 8 14 18 52 CEST 2010 Related Information m matchtopology Command on page 37 m showtopology Command on page 50 m ibnetdiscover Command on page 92 m Linux Shells for Hardware Commands on page 3 getfanspeed Command Displays fan speed 28 Sun Datacenter InfiniBand Switch 36 Command Reference April 2011 Syntax getfanspeed Description This hardware command displays the speed of the fans The comman
24. The following table describes the options to the ibroute command and their purposes Option Purpose a Shows all LIDs in the range including invalid entries n Does not try to resolve destinations d Sets the debug level Can be used several times to increase the debug level D Uses the directed path address The path is a comma delimited sequence of out ports e Displays send and receive errors 102 Sun Datacenter InfiniBand Switch 36 Command Reference April 2011 Option Purpose G Uses the port GUID address h Provides help M Shows multicast forwarding tables s Uses smlid as the target LID for Subnet Manager or Subnet Administrator queries v Provides verbose output V Displays the version information c Uses the specified channel adapter name P Uses the specified channel adapter port t Overrides the default timeout Example The following example shows how to display the forwarding table for LID 15 with the ibroute command Note The output for your InfiniBand fabric will differ from that in the example ibroute 15 Unicast lids 0x0 0xf of switch Lid 15 guid 0x0021283a8389a0a0 Sun DCS 36 QDR switch localhost Lid Out Destination Port Info 0x000e 023 Channel Adapter portguid 0x0003ba000100e38a nsn33 43 HCA 1 0x000f 000 Switch portguid 0x0021283a8389a0a0 Sun DCS 36 QDR switch localhost 2 valid lids dumped Related Information ibroute ma
25. ea bls 6048 MME PK ES 2 aioe sa idos 84 ROVEKES E ie ee ochik cita quacks deena Bee 84 Related Information m ibdatacounts man page m ibaddr Command on page 60 m perfquery Command on page 114 ibdiagnet Command Performs InfiniBand fabric diagnostic Syntax ibdiagnet c count v r o outputdir t topology s system i device p port wt topology pm pc P PM value 1w 1x 4x 12x ls 2 5 5 10 skip checks load_db file h V where m count is the number of packets m outputdir is the output directory m topology is the topology file m system is the local system name m device is the index of the device connecting to the InfiniBand fabric m port is the port of the device m PM is the Performance Manager counter number 82 Sun Datacenter InfiniBand Switch 36 Command Reference April 2011 m value is the threshold of the Performance Manager counter m checks is one or more strings that identify the checks made dup_guids zero_guids pm logical_state part ipoib all m file is the subnet database db file Description This InfiniBand command scans the InfiniBand fabric using directed route packets extracting all the available information regarding the connectivity and devices This command produces a set of files in the output directory By default the output directory is tmp The following table describes the files File Name Descriptio
26. enablelinklog Command on page 20 Command Syntax Links enablesm enableswitchport reason reason connector Switch port env_test exit generatetopology topofile h getfanspeed getmaster 1 getnm2type getportstatus connector Switch port v help command class ibdevreset Switch listlinkup managementreset r matchtopology topofile h setcontrolledhandover state list setloghost IP_address hostname localhost setmsmlocationmonitor state list h setsmpriority priority list setsubnetprefix prefix list showfruinfo showpsufru slot showsmlog h showtemps showtopology h showunhealthy smconfigtest 1 h version enablesm Command on page 21 enableswitchport Command on page 22 env_test Command on page 24 exit Command Hardware on page 26 generatetopology Command on page 27 getfanspeed Command on page 28 getmaster Command on page 29 getnm2type Command on page 30 getportstatus Command on page 31 help Command Hardware on page 32 ibdevreset Command on page 34 listlinkup Command on page 35 managementreset Command on page 36 11 matchtopology Command on page 37 1 setcontrolledhandover Command on page 38 setloghost Command on page 40 setmsmlocationmonitor Command on page 41 setsmpriority Command on page 42 setsubnetprefix Comm
27. enables the ilom admin user and users with similar permissions to run both diagnostic and fabric management commands Note The ilom operator user cannot access the Linux shell from the SYS Fabric_Mgmt target Understanding InfiniBand Commands 59 The following table lists the InfiniBand commands and their availability from the respective Linux shell targets Typing the help all command from within the restricted shells lists the commands available to that shell Note InfiniBand commands that are not listed are unavailable from the SYS Switch_Diag or SYS Fabric_Mgmt targets Command SYS Switch_Diag SYS Fabric_Mgmt ibdiagnet Available ibhosts Available Available ibnetstatus Available Available ibnodes Available Available ibportstate Available Available ibroute Available Available ibrouters Available Available ibstat Available Available ibswitches Available Available ibtracert Available Available perfquery Available Available saquery Available smpquery Available Available Related Information m Linux Shells for Hardware Commands on page 3 ibaddr Command Queries InfiniBand addresses 60 Sun Datacenter InfiniBand Switch 36 Command Reference April 2011 Syntax ibaddr d D G 11 91 C ca_name P ca_port t timeout V h lid dr_path guid where ca_name is the channel adapter name ca_port is the channel adapter port timeout is the timeout in milliseconds lid i
28. help List of avaliable classes general diag ibdiag sm other all Type help Type help General commands Switch diagnostics commands Infiniband diagnostics commands Subnet Managager administration commands Other managagement commands Show all commands followed by a class name for a list of commands in that class followed by a command name for description and usage of the command Related Information m Switch Remote Administration help command m Linux Shells for Hardware Commands on page 3 Understanding Hardware Commands 33 ibdevreset Command Resets the switch chip Syntax ibdevreset Switch Description This hardware command resets the switch chip Example The following example shows how to reset the switch chip with the ibdevreset command ibdevreset Switch Stopping IB Subnet Manager OK Stopping whereismaster daemon OK Stopping Environment daemon OK Resetting Switch Starting Environment daemon OK Starting whereismaster daemon OK Starting IB Subnet Manager OK Related Information m checkboot Command on page 6 m ibportstate Command on page 99 34 Sun Datacenter InfiniBand Switch 36 Command Reference April 2011 listlinkup Command Displays links presence Syntax listlinkup Description This hardware command lists the presence of links and the up down state of the associated ports on the switch chip N
29. ibcheckport h v N G C ca_name P ca_port t timeout lid guid port where m ca_name is the channel adapter name m ca_port is the channel adapter port m timeout is the timeout in milliseconds m lid is the local identifier guid is the global unique identifier port is the port being validated Description This InfiniBand command checks port connectivity and performs simple sanity checks for the specified port Note The port address is a LID unless the G option is used to specify a GUID address Options The following table describes the options to the ibcheckport command and their purposes Option Purpose h Provides help v Provides verbose output N Uses mono mode instead of color mode G Uses the port GUID address C Uses the specified channel adapter name P Uses the specified channel adapter port t Overrides the default timeout 68 Sun Datacenter InfiniBand Switch 36 Command Reference April 2011 Example The following example shows how to check port 23 on LID 15 with the ibcheckport command ibcheckport v 15 23 Port check lid 15 port 23 OK Related Information ibcheckport man page m getportstatus Command on page 31 m ibaddr Command on page 60 a smpquery Command on page 124 ibcheckportstate Command Validates an InfiniBand port Syntax ibcheckportstate v G h N C ca_name P ca_port t timeout l
30. local system this option specifies the index of the device of the port used to connect to the InfiniBand fabric Specifies the local device port number used to connect to the InfiniBand fabric Specifies the output directory 88 Sun Datacenter InfiniBand Switch 36 Command Reference April 2011 Option Purpose 1w Specifies the expected link width 1s Specifies the expected link speed pm Dumps all the fabric link Performance Manager counters into ibdiagpath pm pc Resets all the fabric link Performance Manager counters P Use the Performance Manager counter of PM set to the threshold of value h Provides help V Displays the version information Example The following example shows how to display the route from LID 15 to LID 14 with the ibdiagpath command Note The output for your InfiniBand fabric will differ from that in the example ibdiagpath 1 14 15 Loading IBDIAGPATH from usr lib ibdiagpath1 2 W Topology file is not specified Reports regarding cluster links will use direct routes Loading IBDM from usr lib ibdm1 2 I Using port 0 as the local port I PE IS E E SNA IA E A E A E EN a I Traversing the path from local to source I From lid 0x000f guid 0x0021283a8389a0a0 dev 48438 Port 23 I To 1id 0x000e guid 0x0003ba000100e38a dev 26428 nsn33 43 P2 I From 1id 0x000e guid 0x0003ba000100e38a dev 26428 nsn33 43 P2 I To 1id 0x000f guid 0x0021283a8389a0a0 dev 4
31. m ca_name is the channel adapter name m ca_port is the channel adapter port m timeout is the timeout in milliseconds m guid is the global unique identifier m port is the port being validated Description This InfiniBand command checks connectivity and if the specified port is at 1x link width Note The port address is a LID unless the G option is used to specify a GUID address Options The following table describes the options to the ibcheckportwidth command and their purposes Option Purpose G Uses the port GUID address h Provides help N Uses mono mode instead of color mode Understanding InfiniBand Commands 71 Option Purpose Q Uses the specified channel adapter name P Uses the specified channel adapter port Overrides the default timeout Example The following example shows how to check the width of port 23 on LID 15 with the ibcheckportwidth command ibcheckportwidth v 15 23 Port check lid 15 port 23 OK Related Information m ibcheckportwidth man page m getportstatus Command on page 31 m ibaddr Command on page 60 m smpquery Command on page 124 ibcheckstate Command Displays ports that are LinkUp but not Active Syntax ibcheckstate h N v topology C ca_name P ca_port t timeout where m topology is the topology file m ca_name is the channel adapter name m ca_port is the channel adapter port
32. nodes and systems Hop count information containing maximal hop count an example path and a hop count histogram m All CA to CA paths traced m Credit loop report a MGID MLID HCAs multicast group and report m Partitions report m IPoIB report Note If the InfiniBand fabric includes only one CA then CA to CA paths are not reported Additionally if a topology file is provided the ibdiagnet command uses the names defined in the topology file for the output reports The ibdiagnet command is available from the SYS Fabric_Mgmt Linux shell target of the Oracle ILOM CLI interface Options The following table describes the options to the ibdiagnet command and their purposes Option Purpose c Sets the minimum number of packets sent across each link v Provides verbose output r Provides a report of fabric qualities t Specifies the topology file name s Specifies the local system name i In the case of multiple devices on the local system this option specifies the index of the device of the port used to connect to the InfiniBand fabric p Specifies the local device port number used to connect to the InfiniBand fabric 84 Sun Datacenter InfiniBand Switch 36 Command Reference April 2011 Option Purpose 0 Specifies the output directory 1w Specifies the expected link width 1s Specifies the expected link speed pm Dumps all the fabric link Performance Manager counters into ibdiagnet
33. of the QSFP connector 04 178 m port is the number of the port 1 36 Description This hardware command disables a QSFP connector and port on the switch chip The command addresses either the connector or the port on the switch chip The reason option enables you to use a passphrase to lock the state of the port 18 Sun Datacenter InfiniBand Switch 36 Command Reference April 2011 m Blacklist A connector and port pair are identified as being inaccessible because of unreliable operation m Partition A connector and port pair are identified as being isolated from the InfiniBand fabric Both the Blacklist and Partition passphrases survive reboot and are unlocked using the enableswitchport command with the reason option Note State changes made with the ibportstate command are not recognized by the disableswitchport enableswitchport or listlinkup commands The disableswitchport command is available from the SYS Fabric_Mgmt Linux shell target of the Oracle ILOM CLI interface Example The following example shows how to disable and blacklist connector 14A with the disableswitchport command disableswitchport reason Blacklist 14A Disable Switch port 7 reason Blacklist Initial PortInfo t Port info DR path slid 65535 dlid 65535 0 port 7 LINnKState tsi hee tie epee eee ees Down PhysSLinkState oi resed ace aiias ao Polling LinkWidthSupported 1X or 4X LinkWidthEnabled
34. options to the ibportstate command and their purposes Option Purpose d Sets the debug level Can be used several times to increase the debug level D Uses the directed path address The path is a comma delimited sequence of out ports e Displays send and receive errors G Uses the port GUID address h Provides help s Uses smlid as the target LID for Subnet Manager or Subnet Administrator queries v Provides verbose output G Uses the specified channel adapter name P Uses the specified channel adapter port t Overrides the default timeout 100 Sun Datacenter InfiniBand Switch 36 Command Reference April 2011 Example The following example shows how to query the state and link speed of LID 15 port 23 with the ibportstate command ibportstate 15 23 Peer PortiInfo Port info Lid 15 DR path slid 15 dlid 65535 0 23 PortInfo Port info Lid 15 port 23 bInkStatel ss ek5 00d Sale ee oe eae ee Active PhyshinkState i o4sies aha eee es LinkUp LinkWidthSupported 1X or 4X LinkWidthEnabled 1X or 4X LinkWidthActive 0 4X LinkSpeedSupported 2 5 Gbps or 5 0 Gbps or 10 0 Gbps LinkSpeedEnabled 2 5 Gbps or 5 0 Gbps or 10 0 Gbps LinkSpeedActiVe oooooooooooo 10 0 Gbps BINKState ri Rae a ee hs Active PhysLinkState 200 LinkUp LinkWidthSupported 1X or 4X LinkWidthEnabled
35. ou a leur utilisation ES m Adobe PostScript Contents Using This Documentation xvii Understanding Hardware Commands 1 Linux Shells for Hardware Commands chassis_led Command 5 Syntax 5 Description 5 Options 5 Example 6 checkboot Command 6 Syntax 6 Description 6 Example 7 checkguidfilesftree Command 7 Syntax 7 Description 7 Options 8 Example 8 checkpower Command 8 Syntax 8 Description 9 Example 9 3 checktopomax Command 9 Syntax 9 Description 10 Options 10 Example 10 checkvoltages Command 11 Syntax 11 Description 11 Example 11 connector Command 12 Syntax 12 Description 12 Options 13 Example 13 desport Command 14 Syntax 14 Description 14 Options 14 Example 15 disablecablelog Command 15 Syntax 15 Description 15 Example 16 disablelinklog Command 16 Syntax 16 Description 16 Example 17 disablesmCommand 17 iv Sun Datacenter InfiniBand Switch 36 Command Reference April 2011 Syntax 17 Description 17 Example 18 disableswitchport Command 18 Syntax 18 Description 18 Example 19 enablecablelog Command 20 Syntax 20 Description 20 Example 20 enablelinklog Command 20 Syntax 21 Description 21 Example 21 enablesmCommand 21 Syntax 21 Description 22 Example 22 enableswitchport Command 22 Syntax 23 Description 23 Example 23 env_test Command 24 Syntax 24 Description 24 Example 25 exit Command Hardware 26 Contents v Syntax 26 Description 26 Example 26 gener
36. pm pc Resets all the fabric link Performance Manager counters P Uses the Performance Manager counter of PM set to the threshold of value skip Skips the executions of the selected checks One or more checks can be specified wt Writes out the discovered topology into the given file load_db Loads subnet data from the given db file and skips the subnet discovery stage Note Some checks require actual subnet discovery and are disabled if load_db is specified Those checks are for duplicate zero GUIDs link state and Subnet Manager status h Provides help V Displays the version information Example The following example shows how to test the InfiniBand fabric with the ibdiagnet command The command checks for 4x link width and 10 Gbyte sec speed dumps the Performance Manager counters and then clears them Note The output for your InfiniBand fabric will differ from that in the example ibdiagnet lw 4x ls 10 pm pc skip dup_guids Loading IBDIAGNET from usr lib ibdiagnet1 2 W Topology file is not specified Reports regarding cluster links will use direct routes Loading IBDM from usr lib ibdm1 2 I Using port 0 as the local port I Discovering 2 nodes 1 Switches amp 1 CA s discovered I A EN T EPE e ee ee E A I Bad Guids LIDs Info I Pa ae gf E EA a S ey eg I No bad Guids were found I PE A A E S 2 Understanding InfiniBand Commands 85 I Links With Logi
37. shows how to display the InfiniBand fabric topology with the showtopology command Note The output for your InfiniBand fabric will differ from that in the example showtopology DEV26418_02P nsn34 45 HCA 1 P1 4x 10G gt SUNDCS36QDR nsn34 170 C 0A P2 4x 10G gt SUNDCS36QDR nsn34 170 C 0B SUNDCS36QDR nsn34 170 C 17A 4x 10G gt SUNDCS36QDR nsn34 170 C 17B C 17B 4x 10G gt SUNDCS36QDR nsn34 170 C 17A Understanding Hardware Commands 51 52 P2 4x 1 P1 4x 1 Pl 4x 1 P1 4x 1 P2 4x 1 P1 4x 1 P2 4x 1 DEV26418_02P nsn34 DEV26418_02P nsn33 DEV26418_02P nsn34 DEV26418_02P nsn34 C 16A 4x 10G gt C 16B 4x 10G gt C 15A 4x 10G gt C 15B 4x 10G gt C 14A 4x 10G gt C 14B 4x 10G gt C 13A 4x 10G gt C 13B 4x 10G gt C 12A 4x 10G gt C 12B 4x 10G gt C 9B 4x 10G gt SUNDCS36QDR nsn34 170 C 6A C 9A 4x 10G gt DEV26418_02P nsn34 44 HCA 1 P1 C 10B 4x 10G gt C 10A 4x 10G gt C 11B 4x 10G gt C 11A 4x 10G gt C 3A 4x 10G gt SUN C 8A 4x 10G gt SUN LOG gt SUN LOG gt SUN S S S S S S S D D D 23323232322 EV26418_02P nsn34 EV26418_02P nsn34 DEV26418_02P nsn34 41_HCA 1 DCS36QDR nsn34 170 LOG gt SUNDCS36QDR nsn34 170 59_HCA 1 LOG gt SUNDCS36QDR nsn34 170 44_HCA 1 LOG gt SUNDCS36QDR nsn34 170 LOG gt SUNDCS36QDR nsn34 170 42_HCA 1 LOG
38. shows how to display the basic status from the local InfiniBand driver with the ibstat command ibstat Switch is4_0 Switch type MT48436 Number of ports 0 Firmware version 7 3 0 Hardware version a0 Node GUID 0x00212856cfe2c0a0 System image GUID 0x00212856cfe2c0a3 Port 0 State Active Physical state LinkUp Rate 40 Base lid 16 LMC 0 SM lid 16 Capability mask 0x4250084a Port GUID 0x00212856cfe2c0a0 Related Information m ibstat man page m ibstatus Command on page 107 m Linux Shells for InfiniBand Commands on page 59 ibstatus Command Queries basic status of InfiniBand devices Syntax ibstatus h devname ib_port where m devname is the InfiniBand device name Understanding InfiniBand Commands 107 m ib_port is the port number of the InfiniBand device Description This InfiniBand command displays basic information retrieved from the local InfiniBand driver Output of the command includes m LID m SMLID m port logical state m link width m port physical state Note This command is an alternative to the ibstat command Options The h option provides help Example The following example shows how to display the basic status from the local InfiniBand driver with the ibstatus command ibstatus Infiniband device is4_0 port 0 status default gid fe80 0000 0000 0000 0021 283a 8389 a0a0 base lid Oxf sm lid Oxf state 4 ACTIVE ph
39. software revision read entPhysicalSoftwareRev string of the physical entity Display or set the vendor specific serial number read entPhysicalSerialNum string for the physical entity write Display or set the name of the manufacturer of read entPhysicalMfgName the physical component write Display or set the vendor specific model name read entPhysicalModelName string associated with the physical component write Understanding SNMP MIB OIDs 165 Description of Task or Activity Action MIB OID Display or set a handle or alias for the physical read entPhysicalAlias entity as specified by the network manager write Display or set the nonvolatile asset tracking read entPhysicalAssetID identifier for the physical entity as specified by write a network manager Display whether or not the physical entity is read entPhysicalIsFRU considered a field replaceable unit by the vendor Related Information a OID Tables Overview on page 127 a ENTITY MIB MIB OID Command Syntax on page 164 166 Sun Datacenter InfiniBand Switch 36 Command Reference April 2011 Index C chassis_led command 5 checkboot command 6 checkguidfilesftree command 7 checkpower command 8 checktopomax command 9 checkvoltages command 11 command hardware 1 chassis_led 5 checkboot 6 checkguidfilesftree 7 checkpower 8 checktopomax 9 checkvoltages 11 connector 12 dcsport 14 disablecablelog 15 disablelinklog 16 disabl
40. the FRU ID information h Provides help Example The following example shows how to display the FRU ID information for connector 1A with the connector command connector 1A info Cable connector 1A present Indentifier QSFP Connector type Copper pigtail Vendor Amphenol Vendor OUI 415048 Partnumber 568400005 Revision C Serialnumber APF08510050019 Date 081219 Related Information m env_test Command on page 24 m listlinkup Command on page 35 a Linux Shells for Hardware Commands on page 3 Understanding Hardware Commands 13 dcsport Command Maps between switch chip ports and QSFP connectors Syntax dcsport port port connector connector printconnectors where m port is the number of the port 1 36 connector is the number of the QSFP connector 0A 17B Description This hardware command displays the mapping between switch chip ports and QSFP connectors You can specify either a port or a connector The dcsport command is available from the SYS Switch_Diag and SYS Fabric_Mgmt Linux shell targets of the Oracle ILOM CLI interface Options The following table describes the options to the desport command and their purposes Option Purpose port Identifies the port to provide the connector mapping connector Identifies the connector to provide the port mapping printconnectors Displays mapping for all connectors 14 Sun Datacenter I
41. the switch The showtemps command is available from the SYS Switch_Diag and SYS Fabric_Mgmt Linux shell targets of the Oracle ILOM CLI interface Example The following example shows how to display switch temperatures with the showtemps command showtemps Back temperature 29 Front temperature 30 SP temperature 36 Switch temperature 52 maxtemperature 56 All temperatures OK Related Information m env_test Command on page 24 m Linux Shells for Hardware Commands on page 3 Understanding Hardware Commands 49 showt opology Command Displays the topology Syntax showtopology h Description This hardware command displays the InfiniBand fabric topology The showtopology command displays the topology in a format different than the ibnetdiscover command The output of the showtopology command follows this basic format for each node device_type device_name and panel_label link_status gt connected_device_type connected_device_name connected_panel_label panel_label link_status gt connected_device_type connected_device_name connected_panel_label for each subsequent port of that device_type where m device_type is the type of InfiniBand device The device_type might be SUNBONEM48 Sun Blade 6048 InfiniBand QDR Switched Network Express Module DEV26418_01P Single port Sun Blade X6275 Server Module DEV26418_02P Dual port Sun Blade X6275 S
42. toutes les mesures de secours de sauvegarde de redondance et autres mesures n cessaires a son utilisation dans des conditions optimales de s curit Oracle Corporation et ses affili s d clinent toute responsabilit quant aux dommages caus s par l utilisation de ce logiciel ou mat riel pour ce type d applications Oracle et Java sont des marques d pos es d Oracle Corporation et ou de ses affili s Tout autre nom mentionn peut correspondre a des marques appartenant d autres propri taires qu Oracle AMD Opteron le logo AMD et le logo AMD Opteron sont des marques ou des marques co d Advanced Micro Devices Intel et Intel Xeon sont des marques ou des marques d pos es d Intel Corporation Toutes les marques SPARC sont utilis es sous licence et sont des marques ou des marques d pos es de SPARC International Inc UNIX est une marque d pos e conc d e sous licence par X Open Company Ltd Ce logiciel ou mat riel et la documentation qui l accompagne peuvent fournir des informations ou des liens donnant acc s a des contenus des produits et des services manant de tiers Oracle Corporation et ses affili s d clinent toute responsabilit ou garantie expresse quant aux contenus produits ou services manant de tiers En aucun cas Oracle Corporation et ses affili s ne sauraient tre tenus pour responsables des pertes subies des co ts occasionn s ou des dommages caus s par l acc s des contenus produits ou services tiers
43. whether high error rate traps are read ibSnmpPer fHighErrorRateTrapEnable generated write Related Information m OID Tables Overview on page 127 m SUN DCS MIB MIB OID Command Syntax on page 129 Trap Threshold OIDs The following table lists trap threshold object identifiers supported by the SUN DCS MIB MIB Description of Task or Activity Action Display or set whether a trap is generated read should the SymbolErrCounter threshold wri be exceeded te MIB OID ibSnmpPerfSymbolErrCounterThreshold Display or set whether a trap is generated read should the LinkErrRecoveryCntr wri threshold be exceeded te ibSnmpPerfLinkErrRecoveryCntrThreshold Display or set whether a trap is generated read should the LinkDownedCntr threshold be wri exceeded te ibSnmpPerfLinkDownedCntrThreshold Display or set whether a trap is generated read should the PortRevErr threshold be wri exceeded te ibSnmpPerfPortRcvErrThreshold 138 Sun Datacenter InfiniBand Switch 36 Command Reference April 2011 Description of Task or Activity Action MIB OID Display or set whether a trap is generated read ibSnmpPerfPortRcvRemPhysErrThreshold should the PortRcvRemPhysErr write threshold be exceeded Display or set whether a trap is generated read ibSnmpPerfPortRcvSwitchRelayErrThreshold should the PortRevSwitchRelayErr write threshold be
44. will differ from that in the example ibnetdiscover Topology file generated on Sat Apr 13 22 28 55 2002 Max of 1 hops discovered Initiated from node 0021283a8389a0a0 port 0021283a8389a0a0 vendid 0x2c9 devid 0xbd36 sysimgguid 0x21283a8389a0a3 se Ho HH OH e 94 Sun Datacenter InfiniBand Switch 36 Command Reference April 2011 switchguid 0x21283a8389a0a0 21283a8389a0a0 Switch 36 S 0021283a8389a0a0 Sun DCS 36 QDR switch localhost enhanced port O lid 15 lmc O 23 H 0003ba000100e388 2 3ba000100e38a nsn33 43 HCA 1 lid 14 4xQDR vendid 0x2c9 devid 0x673c sysimgguid 0x3ba000100e38b caguid 0x3ba000100e388 Ca 2 H 0003ba000100e388 nsn33 43 HCA 1 2 3ba000100e38a S 0021283a838 9a0a0 23 lid 14 lmc 0 Sun DCS 36 QDR switch localhost lid 15 4xQDR Related Information m ibnetdiscover man page ibnetstatus Command Displays status of the InfiniBand fabric Syntax ibnetstatus h Description This InfiniBand command provides a short status report of the InfiniBand fabric It provides output equivalent to ibdiagnet ls 10 lw 4x The ibnetstatus command is available from the SYS Switch_Diag and SYS Fabric_Mgmt Linux shell targets of the Oracle ILOM CLI interface Options The h option provides help Understanding InfiniBand Commands 95 Example The following example shows how to display the status of the InfiniBand fabric with the ibnetstatus command
45. xi ibdiagpath Command 87 Syntax 87 Description 87 Options 88 Example 89 ibhosts Command 90 Syntax 90 Description 91 Options 91 Example 91 ibnetdiscover Command 92 Syntax 92 Description 92 Options 93 Example 94 ibnetstatus Command 95 Syntax 95 Description 95 Options 95 Example 96 ibnodes Command 97 Syntax 97 Description 98 Options 98 Example 98 ibportstate Command 99 Syntax 99 Description 100 xii Sun Datacenter InfiniBand Switch 36 Command Reference April 2011 Options 100 Example 101 ibroute Command 101 Syntax 102 Description 102 Options 102 Example 103 ibrouters Command 104 Syntax 104 Description 104 Options 104 Example 105 ibstat Command 105 Syntax 105 Description 106 Options 106 Example 107 ibstatus Command 107 Syntax 107 Description 108 Options 108 Example 108 ibswitches Command 109 Syntax 109 Description 109 Options 109 Example 110 ibsysstat Command 110 Contents xiii Syntax 110 Description 111 Options 111 Example 112 ibtracert Command 112 Syntax 113 Description 113 Options 113 Example 114 perfquery Command 114 Syntax 115 Description 115 Options 115 Example 116 saquery Command 117 Syntax 117 Description 118 Options 118 Example 119 sminfoCommand 120 Syntax 120 Description 121 Options 121 Example 122 smpdump Command 122 Syntax 122 Description 123 Options 123 xiv Sun Datacenter InfiniBand Switch 36 Command Reference April 2011 Example 123 smpquery Command 124 Syntax
46. 0100827 09 27 45 No Master SubnetManager 20100908 15 00 18 Master SubnetManager on SUN DCS 36P QDR nsn34 170 sm lid 0 sm sm lid 2 sm seen in the sm lid 2 sm guid 0x21283a83eea0a0 guid 0x21283a83eea0a0 system guid 0x21283a83eea0a0 Related Information m sminfo Command on page 120 m Linux Shells for Hardware Commands on page 3 getnm2 type Command Displays the device type 30 Sun Datacenter InfiniBand Switch 36 Command Reference April 2011 Syntax getnm2type Description This hardware command displays the type of InfiniBand device the management controller is installed within The output is m gw Sun Network QDR InfiniBand Gateway Switch m 36p Sun Datacenter InfiniBand Switch 36 m 72p Sun Datacenter InfiniBand Switch 72 Example The following example shows how to display the type of InfiniBand device with the getnm2type command getnm2type 36p Related Information m version Command Hardware on page 55 getportstatus Command Displays port status Syntax getportstatus connector Switch port v where connector is the number of the QSFP connector 0A 17B Understanding Hardware Commands 31 m port is the number of the port 1 36 Description This hardware command returns the status of the specified connector or port of the switch chip The v option provides verbose output Example The following example shows how
47. 0e388 Node check lid 14 OK Port check lid 14 port 2 OK Summary 5 nodes checked 0 bad nodes found HH 10 ports checked 0 ports with 1x width in error found Related Information m ibcheckwidth man page Understanding InfiniBand Commands 75 76 ibchecknode Command on page 66 ibcheckportwidth Command on page 71 ibnetdiscover Command on page 92 ibclearcounters Command Clears port counters in the InfiniBand fabric Syntax ibclearcounters h topology C ca_name P ca_port t timeout where topology is the topology file ca_name is the channel adapter name ca_port is the channel adapter port timeout is the timeout in milliseconds Description This InfiniBand command is a script that clears the Performance Manager agent port counters by either discovering the InfiniBand fabric topology or using an existing topology file The counters are XmtData RevData XmtPkts RevPkts Sun Datacenter InfiniBand Switch 36 Command Reference April 2011 Options The following table describes the options to the ibclearcounters command and their purposes Option Purpose h Provides help C Uses the specified channel adapter name P Uses the specified channel adapter port t Overrides the default timeout Example The following example shows how to clear the Performance Manager agent port counters with the ibclearcounters command ibclearcounters Summary 5
48. 100 lid 25 port 28 Error check on lid 25 Sun DCS 72 QDR FC switch o4nm2 72p 2 port 28 FAILED warn counter RcvSwRelayErrors 56839 threshold 100 lid 25 port 9 Error check on lid 25 Sun DCS 72 QDR FC switch o4nm2 72p 2 port 9 FAILED Understanding InfiniBand Commands 63 warn counter XmtDiscards 9714 threshold 100 lid 25 port 1 Error check on lid 25 Sun DCS 72 QDR FC switch o4nm2 72p 2 port 1 FAILED Summary 6 nodes checked 0 bad nodes found 142 ports checked 3 ports have errors beyond threshold Related Information m ibcheckerrors man page m ibchecknode Command on page 66 m ibcheckport Command on page 67 m ibnetdiscover Command on page 92 senal ibchecknet Command A simplified version of the ibcheckerrors command Syntax ibchecknet h N topology C ca_name P ca_port t timeout where m topology is the topology file m ca_name is the channel adapter name m ca_port is the channel adapter port m timeout is the timeout in milliseconds Description This InfiniBand command is a script that uses the topology file created by the ibnetdiscover command to scan the InfiniBand fabric to validate the connectivity and report errors from the port counters 64 Sun Datacenter InfiniBand Switch 36 Command Reference April 2011 Options The following table describes the options to the ibchecknet command and their purposes Option Purpose h P
49. 50 showunhealthy command 53 smconfigtest command 54 sminfo command 120 smpdump command 122 smpquery command 124 SNMP MIB OIDs 127 tables overview 127 SUN DCS MIB enclosure nodes OIDs 130 enclosure OIDs 130 MIB OIDs 128 neighbor node OIDs 131 OID command syntax 129 Performance Manager agent OIDs 134 PMA extended port counters OIDs 136 PMA port counters OIDs 135 SNMP trap control OIDs 138 SNMP trap notification OIDs 140 SNMP trap OIDs 137 SNMP trap threshold OIDs 138 Subnet Manager agent OIDs 132 Subnet Manager OIDs 132 SUN HW TRAP MIB MIB OIDs 141 SUN ILOM CONTROL MIB alert OIDs 150 backup and restore OIDs 151 clock OIDs 151 event log OIDs 149 HTTP OIDs 145 HTTPS OIDs 146 identification OIDs 152 MIB OIDs 142 network OIDs 146 NTP OIDs 144 OID command syntax 143 remote syslog OIDs 145 session OIDs 148 SMTP OIDs 152 user OIDs 148 SUN PLATFORM MIB alarm OIDs 161 binary sensor OIDs 157 discrete sensor OIDs 160 discrete sensor state OIDs 160 fan OIDs 161 high level OIDs 155 MIB OIDs 153 MIB physical OIDs 154 MIB trap OIDs 162 NIM equipment OIDs 155 numeric sensor OIDs 158 OID command syntax 153 physical class extension OIDs 156 sensor OIDs 157 understanding hardware commands 1 InfiniBand commands 57 version command 55 Index 169 170 Sun Datacenter InfiniBand Switch 36 Command Reference April 2011
50. 8438 Port 23 I A A A SS SA A id a Se ees Be I PM Counters Info I Aa a A A A a A a A ct tae 1 No illegal PM counters values were found I AAA EIA AE AA AE A I Path Partitions Report I PE ENA a a E E el E E E NR A ENEN EN Sats mi E EE E EAE E E E eS E ae I Source nsn33 43 P2 lid 0x000e guid 0x0003ba000100e38a dev 26428 Port 2 PKeys 0xffff Understanding InfiniBand Commands 89 I Destination 1id 0x000f guid 0x0021283a8389a0a0 dev 48438 PKeys 0xffff I Path shared PKeys Oxffff I A ii a a a a A I IPoIB Path Check I A o A G a gn G ed I Subnet IPv4 PKey 0x7fff OKey 0x00000b1b MTU 2048Byte rate 10Gbps SL 0x00 I A A a a a lt p Sa Ss Gas a I QoS on Path Check I A a a a Sn Smet A Sag de G A i secs GSS a Sa Sm SSN mg ua Sls im GS Sun ass e ol I The following SLs can be used 0 123 45 678 9 10 11 12 13 14 15 I Stages Status Report STAGE Errors Warnings LFT Traversal local to source LFT Traversal source to destination Performance Counters Report Path Partitions Check Path IPoIB Check QoS on Path Check Please see tmp ibdiagpath log for complete log Ooo0oooo o0o00o0ooooO I Done Run time was 0 seconds Related Information m ibdiagpath man page m ibdiagnet Command on page 82 ee ibhosts Command Displays host nodes Syntax ibhosts h topology C ca_name P ca_port t timeout where m topology is the topology file m ca_name
51. A AAA A I Links With links width 4x as set by lw option deta T E ARS A AAA IA ES PRA ON nik ASIN AN e TS I No unmatched Links with width 4x were found as T A A as aca ee hy ns a a i Meh a can Seely ST a ncn dae a as es ee I Links With links speed 10 as set by ls option i T SRA IP IE a a A E Sa ah a i AA PS AS E eS ak ed a I No unmatched Links with speed 10 were found ray I A A a A A A a a a 96 Sun Datacenter InfiniBand Switch 36 Command Reference April 2011 I Fabric Partitions Report see ibdiagnet pkey for a full hosts list I IPoIB Subnets Check I pe E E E EE EEEE A EE E iii EE E EE I Subnet IPv4 PKey 0x0001 QKey 0x00000b1b MTU 2048Byte rate 10Gbps SL 0x00 W No members found for group I Subnet IPv4 PKey 0x7fff OKey 0x00000b1b MTU 2048Byte rate 10Gbps SL 0x00 W No members found for group I Fa a ce sp e ees aa a a ps se as iy wk a a ast A a ar nme a a a e a ig SS te a ps a I Bad Links Info I No bad link were found I A A A A EAS I Stages Status Report STAGE rrors Warnings Bad GUIDs LIDs Check 0 Link State Active Check 0 0 Performance Counters Report 0 4 Specific Link Width Check 0 0 0 0 0 0 0 2 Specific Link Speed Check Partitions Check IPoIB Subnets Check I Done Run time was 22 seconds Related Information m ibnetstatus man page m ibdiagnet Command on page 82 m Linux Shells for InfiniBand Commands on page 59 ibno
52. Address given target write Display or set the pending IP gateway for the read ilomCtr1NetworkPendingIpGateway given target write Display or set the pending IP netmask for the read ilomCtr1NetworkPendingIpNetmask given target write Commit pending properties read ilomCtr1NetworkCommit Pending write Display or set the pending management port for read ilomCtr1NetworkPendingManagement Por the given target write t Display or set the current management port for read ilomCtr1NetworkManagement Port the given target write Display the address of the DHCP server for the read ilomCtr1NetworkDHCPServerAddr given target Display or set whether or not the parameters are read ilomCtriNetworkState enabled write Related Information m OID Tables Overview on page 127 m SUN ILOM CONTROL MIB MIB OID Command Syntax on page 143 Understanding SNMP MIB OIDs 147 User OIDs The following table lists user object identifiers supported by the SUN ILOM CONTROL MIB MIB Description of Task or Activity Action MIB OID Display a table of information about the current read ilomCtrlLocalUserTable local users with their password state Display information about a local user in the read ilomCtrlLocalUserEntry database Display the user name of a local user on the read ilomCtrlLocalUserUsername device Set the password of a local user on the device read ilomCtrlLocalUserPassword write Di
53. Band fabric for data counters Syntax ibdatacounters b h N v topology C ca_name P ca_port t timeout where m topology is the topology file m ca_name is the channel adapter name m ca_port is the channel adapter port m timeout is the timeout in milliseconds Description This InfiniBand command is a script that uses the topology file created by the ibnetdiscover command The script scans the InfiniBand fabric to validate the connectivity and reports the values of the data counters Options The following table describes the options to the ibdatacounters command and their purposes Option Purpose b Enables brief mode Reduced output is only if errors are present Does not identify the errors h Provides help N Uses mono mode instead of color mode v Provides verbose output Understanding InfiniBand Commands 79 Option Purpose Q Uses the specified channel adapter name P Uses the specified channel adapter port Overrides the default timeout Example The following example shows how to display the data counters for all ports with the ibdatacounters command Note You might see more output than what is in the example ibdatacounters Summary 5 nodes checked 0 bad nodes found 10 ports checked Related Information m ibdatacounters man page a ibdatacounts Command on page 80 m ibnetdiscover Command on page 92 ibdatacou
54. Command Reference April 2011 Note By rebooting the management controller the link to the management console is severed You must re access the management controller to regain administrative control managementreset Stopping Environment daemon please wait Resetting CPLD please wait Restarting Environment daemon Reboot needed to reconnect to I4 and enable IB ports Do you want do reboot now yes no yes Broadcast message from root pts 0 Fri Nov 20 17 10 27 2009 The system is going down for reboot NOW Connection to 123 45 67 89 closed by remote host Connection to 123 45 67 89 closed Related Information m ibdevreset Command on page 34 m ibportstate Command on page 99 matchtopology Command Compares topology file to InfiniBand fabric Syntax matchtopology topofile h where topofile is the filename and path to the topology file Description This hardware command compares the topology file created with the generatetopology command with the current InfiniBand fabric topology An error is displayed upon mismatch The h option provides help Understanding Hardware Commands 37 The matchtopology command is available from the SYS Fabric_Mgmt Linux shell target of the Oracle ILOM CLI interface Example The following example shows how to compare the topology file to the current topology with the matchtopology command matchtopology Sept8 topo Topology matching
55. Information m OID Tables Overview on page 127 m SUN PLATFORM MIB MIB OID Command Syntax on page 153 Sun Platform Alarm Table OIDs The following table lists alarm object identifiers supported by the SUN PLATFORM MIB MIB Description of Task or Activity Action MIB OID Display a table with indications of alarm states read sunPlatAlarmTable Display information about a piece of equipment read sunPlatAlarmEntry with an sunPlatPhysicalClass of alarm 2 Display the type of alarm read sunPlatAlarmType Display or set the state of the alarm read sunPlatAlarmState write Display or set the urgency of the alarm read sunPlatAlarmUrgency Related Information m OID Tables Overview on page 127 m SUN PLATFORM MIB MIB OID Command Syntax on page 153 Understanding SNMP MIB OIDs 161 MIB Trap OIDs The following table lists MIB trap object identifiers supported by the SUN PLATFORM MIB MIB Description of Task or Activity Action MIB OID Display or set a unique ID for the notification read sunPla No tifica tionEventiId Display the time that the notification was generated read sunPla No tifica tionTime Display the name of the object to which the notification applies read sunPla No tifica tionObject Display the perceived severity of the alarm as specified by the agent that generated it read sunPla N
56. Manager ILOM PDF Online information 3 0 Supplement for the Sun Datacenter InfiniBand HTML Switch 36 The Oracle ILOM 3 0 documents listed as online are available at http www oracle com pls topic lookup ctx E19860 01 amp id homepage Application Title Format Location Last minute Oracle Integrated Lights Out Manager ILOM 3 0 PDF Online information Feature Updates and Release Notes HTML Getting started Oracle Integrated Lights Out Manager ILOM 3 0 PDF Online Getting Started Guide HTML Overview Oracle Integrated Lights Out Manager ILOM 3 0 PDF Online Concepts Guide HTML Administration Oracle Integrated Lights Out Manager ILOM 3 0 PDF Online from web Web Procedures Guide HTML interface Administration Oracle Integrated Lights Out Manager ILOM 3 0 PDF Online from CLI CLI Procedures Guide HTML interface Administration Oracle Integrated Lights Out Manager ILOM 3 0 PDF Online from SNMP and Management Protocols Reference Guide HTML IPMI interface Documentation Support and Training These web sites provide additional resources Documentation dex htm1 E Support https support oracle com Sun Datacenter InfiniBand Switch 36 Command Reference April 2011 http www oracle com technetwork documentation in m Training https education oracle com Using This Documentation xix XX Sun Datacenter InfiniBand Switch 36 Command Reference April 2011 Understanding Hardware
57. N PLATFORM MIB MIB OID Command Syntax on page 153 164 Sun Datacenter InfiniBand Switch 36 Command Reference April 2011 Physical Entity Table OIDs The following table lists physical entity object identifiers supported by the ENTITY MIB MIB Description of Task or Activity Action MIB OID Display a table of information about the read entPhysicalTable physical entities Display information about a particular physical read entPhysicalEntry entity Display the index of the physical entity read entPhysicalIndex Display or set the description of the physical read entPhysicalDescr entity write Display or set the vendor specific hardware read entPhysicalVendorType type of the physical entity write Display the value of entPhysical Index for read entPhysicalContainedIn the physical entity which is the container for this physical entity Display or set the general hardware type of the read entPhysicalClass physical entity write Display or set an indication of the relative read entPhysicalParentRelPos position of the child component among all its write sibling components Display or set the name of the physical entity read entPhysicalName write Display or set the vendor specific hardware read entPhysicalHardwareRev revision string of the physical entity write Display the vendor specific firmware revision read entPhysicalFirmwareRev string of the physical entity Display the vendor specific
58. Shells for Hardware Commands on page 3 showpsufru Command Displays power supply FRU ID information Syntax showpsufru slot where slot is the power supply slot 0 or 1 46 Sun Datacenter InfiniBand Switch 36 Command Reference April 2011 Description This hardware command displays FRU ID information for the power supplies The showpsufru command is available from the SYS Switch_Diag and SYS Fabric_Mgmt Linux shell targets of the Oracle ILOM CLI interface Example The following example shows how to display the FRU ID information for power supply 0 with the showpsufru command showpsufru 0 Sun_SpecPartNo 885 1165 02 UNIX_Timestamp32 Wed May 6 09 18 21 2009 Sun_Part_Number gt 3002143 Sun_Serial_No BFOCGS Vendor_ID_Code O2a2 Initial_HW_Dash_Level 02 PSU_Voltage 1 0x04b0 1200 PSU_Current 1 Ox186a 6250 PSU_Voltage 2 0x014a 330 PSU_Current 2 Ox012c 300 Sun_Hazard_Class_Code s Y IPMI_Board_Manufacturer EMERSON IPMI_Board_Product_Name A237 IPMI_Board_Serial_Number 1357ZHO 0919BFOCG5 IPMI_Board_Part_Number 300 2143 02 Related Information m showfruinfo Command on page 45 m Linux Shells for Hardware Commands on page 3 showsmlog Command Displays the Subnet Manager log Understanding Hardware Commands 47 Syntax showsmlog h Description This hardware command displays the log entries for the Subnet Manager within the man
59. Sun Datacenter InfiniBand Switch 36 Command Reference Sy ESO S u n Part No 820 7747 13 aj Xal MS April 2011 Revision A Copyright 2009 2011 Oracle and or its affiliates All rights reserved This software and related documentation are provided under a license agreement containing restrictions on use and disclosure and are protected by intellectual property laws Except as expressly permitted in your license agreement or allowed by law you may not use copy reproduce translate broadcast modify license transmit distribute exhibit perform publish or display any part in any form or by any means Reverse engineering disassembly or decompilation of this software unless required by law for interoperability is prohibited The information contained herein is subject to change without notice and is not warranted to be error free If you find any errors please report them to us in writing If this is software or related software documentation that is delivered to the U S Government or anyone licensing it on behalf of the U S Government the following notice is applicable U S GOVERNMENT RIGHTS Programs software databases and related documentation and technical data delivered to U S Government customers are commercial computer software or commercial technical data pursuant to the applicable Federal Acquisition Regulation and agency specific ja ieee oleae regulations As such the use duplication disclosure modificatio
60. TRAP MIB MIB OIDs on page 141 m Understanding the SUN ILOM CONTROL MII m Understanding the ENTITY MIB MIB OIDs B MIB OIDs on page 142 on page 163 SUN PLATFORM MIB MIB OID Command Syntax When you use the object identifiers in a command syntax you must include the SUN PLATFORM MIB MIB name For example using the V2c protocol command v2c c public mc_IP SUN PLATFORM MIB object_id argument Or using the V3 protocol command v3 u snmp_user 1 security_level a authentication_protocol A authentication_password ES X privacy_password mc_IP SUN PLATFORM MIB object_id argument x DI where command is the command of the SNMP client that performs the action m snmp_user is a configured user of the SNMP services m security_level is noAuthNoPriv There is no authentication or privacy Understanding SNMP MIB OIDs 153 authNoPriv There is authentication but no privacy authPriv There is authentication and privacy m authentication_protocol is either MD5 or SHA m authentication_password is the snmp_user s authentication password m privacy_password is the snmp_user s privacy password a mc_IP is the IP address of the management controller m object_id is the object identifier as listed in the right column of the tables m argument is a combination of options and variables that support the object identifier For example to securely display a t
61. UN DCS MIB MIB Description of Task or Activity Action MIB OID Display a table of information about read ibNeighborTable neighboring InfiniBand nodes Display a row of the ibNodeNeighborTable read ibNeighborEntry Display an index of neighboring InfiniBand read ibNeighNodeIndex nodes Display an index of neighboring InfiniBand read ibNeighPort Index node data ports Display the type of remote InfiniBand node read ibNeighRemoteNodeType switch CA and so on Display the GUID of the remote node read ibNeighRemoteNodeGuid Display the number of ports of the remote node read ibNeighRemoteNodePort Display the NodeDescription of the remote read ibNeighRemoteNodeDescr node Display the LID of the remote node read ibNeighRemoteNodeLid Display a mapping of neighboring InfiniBand read ibNeighPortConnectorPosition device port to connector Related Information a OID Tables Overview on page 127 Understanding SNMP MIB OIDs 131 m SUN DCS MIB MIB OID Command Syntax on page 129 Subnet Manager Info OIDs The following table lists Subnet Manager object identifiers supported by the SUN DCS MIB MIB Description of Task or Activity Action MIB OID Identify the master Subnet Manager in the read smMasterSMPresent subnet Display the LID of the master Subnet Manager read smMasterSMLid Display the GUID of the master Subnet read smMasterSMGuid Manager Display infor
62. a table of attributes read sunPlatNumericSensorTable specific to numeric sensors Display information about a read sunPlatNumericSensorEntry sensor with a sunPlatSensorClass value of numeric 2 Display the base unit of the value read sunPlatNumericSensorBaseUnits returned by the sensor For example volts Display the exponent of 10 tobe read sunPlatNumericSensorExponent multiplied by the base unit For example 2 So the multiplier is 1042 or 100 Display or set the rate associated read sunPlatNumericSensorRateUnits with the base units if any For example per second Display the current reading of the read sunPlatNumericSensorCurrent sensor Display or set the lowest expected read sunPlatNumericSensorNormalMin value from the sensor Display the highest expected read sunPlatNumericSensorNormalMax value from the sensor 158 Sun Datacenter InfiniBand Switch 36 Command Reference April 2011 Description of Task or Activity Action MIB OID Display or set the accuracy of the read sunPlatNumericSensorAccuracy sensor expressed as a value in units of 100ths of a percent Display or set the lower threshold read sunPlatNumericSensorLowerThresholdNonCritical at which a noncritical condition write occurs Display or set the upper threshold read sunPlatNumericSensorUpperThresholdNonCritical at which a noncritical condition write occurs Display
63. able of switch components addressable by the management controller with IP address of 123 45 67 89 snmpwalk v3 u usersnmp 1 authPriv a MD5 A authpass x DES X privpass 123 45 67 89 SUN PLATFORM MIB sunPlatEquipment Table Related Information m SUN DCS MIB MIB OID Command Syntax on page 129 m SUN ILOM CONTROL MIB MIB OID Command Syntax on page 143 m ENTITY MIB MIB OID Command Syntax on page 164 Understanding MIB Physical OIDs Sensor and hardware information object identifiers are provided in these tables m High Level OIDs on page 155 a NIM Equipment Table OIDs on page 155 m Physical Class Extension Table OIDs on page 156 m Sun Platform Sensor Table OIDs on page 157 m Sun Platform Binary Sensor Table OIDs on page 157 a Sun Platform Numeric Sensor Table OIDs on page 158 m Discrete Sensor Table OIDs on page 160 m Discrete Sensor States Table OIDs on page 160 m Sun Platform Fan Table OIDs on page 161 a Sun Platform Alarm Table OIDs on page 161 154 Sun Datacenter InfiniBand Switch 36 Command Reference April 2011 Related Information m MIB Trap OIDs on page 162 m OID Tables Overview on page 127 m Understanding the SUN DCS MIB MIB OIDs on page 128 m SUN HW TRAP MIB MIB OIDs on page 141 m Understanding the SUN ILOM CONTROL MIB MIB OIDs on page 142 m Understanding the ENTITY MIB MIB OIDs o
64. ableswitchport command enableswitchport reason Blacklist 14A Enable Switch port 7 Initial PortInfo Port info DR path slid 65535 dlid 65535 LINKStatet wii eee dad Ae E a Down PhysLinkState ooooooo ooo oo Disabled LinkWidthSupported 1X or 4X LinkWidthEnabled 1X or 4X 2 5 Gbps or 2 5 Gbps or 2 5 Gbps LinkSpeedAc After PortInfo set Port info DR path slid 65535 dlid 65535 Understanding Hardware Commands 0 port 7 5 0 Gbps or 10 0 Gbps 5 0 Gbps or 10 0 Gbps 0 port 7 23 Related Information m disableswitchport Command on page 18 m ibportstate Command on page 99 m getportstatus Command on page 31 m Linux Shells for Hardware Commands on page 3 env_test Command Displays environmental status Syntax env_test Description This hardware command performs a series of hardware and environmental tests of the switch This command is an amalgamation of the following commands m checkpower m checkvoltages m showtemps m getfanspeed m connector m checkboot The command output provides voltage and temperature values pass fail results and error messages The env_test command is available from the SYS Switch_Diag and SYS Fabric_Mgmt Linux shell targets of the Oracle ILOM CLI interface 24 Sun Datacenter InfiniBand Switch 36 Command Reference April 2011 Example The following example shows how to displa
65. agement controller The output of the command is an invocation of less var log opensm log Tapping the space bar displays the next screen of the log Pressing the Q key quits The h option provides help The showsmlog command is available from the SYS Switch_Diag and SYS Fabric_Mgmt Linux shell targets of the Oracle ILOM CLI interface Example The following example shows how to display the Subnet Manager log with the showsmlog command Note The output of the example is a very small portion and will differ from your output showsmlog Aug 13 15 58 22 679655 B75F1B90 0x01 gt osm_mcmr_rcv_join_mgrp ERR 1B11 method Subn AdmSet scope _state 0x1 component mask 0x0000000000010003 expected comp mask 0x0000 0000000130c7 MGID ff12 e01b 2 22 2000 from port 0x0003ba000100e371 nsn34 60 HCA 1 Aug 13 15 58 22 692653 B75F1B90 0x01 gt osm_mcmr_rcv_join_mgrp ERR 1B11 method Subn AdmSet scope _state 0x1 component mask 0x0000000000010003 expected comp mask 0x0000 0000000130c7 MGID ff12 e01b 3 22 b000 from port 0x00212800013ece9f nsn34 55 HCA 1 48 Sun Datacenter InfiniBand Switch 36 Command Reference April 2011 Related Information m setloghost Command on page 40 m Linux Shells for Hardware Commands on page 3 showtemps Command Displays switch temperatures Syntax showtemps Description This hardware command displays internal temperatures for
66. and on page 44 showfruinfo Command on page 45 showpsufru Command on page 46 showsmlog Command on page 47 showtemps Command on page 49 showtopology Command on page 50 showunhealthy Command on page 53 smconfigtest Command on page 54 version Command Hardware on page 55 2 Sun Datacenter InfiniBand Switch 36 Command Reference April 2011 Related Information Understanding InfiniBand Commands on page 57 Linux Shells for Hardware Commands The preferred method of accessing the Linux shell is through the SYS Switch_Diag and SYS Fabric_Mgmt Linux shell targets of the Oracle ILOM CLI interface Using the show command on the SYS Switch_Diag target opens a restricted Linux shell that enables the ilom admin user ilom operator user and users with similar permissions to run diagnostic commands Using the show command on the SYS Fabric_Mgmt target opens a different restricted Linux shell that enables the ilom admin user and users with similar permissions to run both diagnostic and fabric management commands Note The ilom operator user cannot access the Linux shell from the SYS Fabric_Mgmt target The following table lists the hardware commands and their availability from the respective Linux shell targets Typing the help all command from within the restricted shells lists the commands available to that shell Note Hardware commands that are not liste
67. atetopology Command 27 Syntax 27 Description 27 Example 27 getfanspeed Command 28 Syntax 29 Description 29 Example 29 getmaster Command 29 Syntax 30 Description 30 Example 30 getnm2type Command 30 Syntax 31 Description 31 Example 31 getportstatus Command 31 Syntax 31 Description 32 Example 32 help Command Hardware 32 Syntax 33 Description 33 Example 33 ibdevreset Command 34 Sun Datacenter InfiniBand Switch 36 Command Reference April 2011 Syntax 34 Description 34 Example 34 listlinkup Command 35 Syntax 35 Description 35 Example 35 managementreset Command 36 Syntax 36 Description 36 Example 36 matchtopology Command 37 Syntax 37 Description 37 Example 38 setcontrolledhandover Command 38 Syntax 38 Description 39 Example 40 setloghost Command 40 Syntax 40 Description 41 Example 41 setmsmlocationmonitor Command 41 Syntax 41 Description 42 Example 42 setsmpriority Command 42 Contents vii Syntax 42 Description 42 Example 43 setsubnetprefixCommand 44 Syntax 44 Description 44 Example 45 showfruinfo Command 45 Syntax 45 Description 45 Example 46 showpsufru Command 46 Syntax 46 Description 47 Example 47 showsmlog Command 47 Syntax 48 Description 48 Example 48 showtemps Command 49 Syntax 49 Description 49 Example 49 showtopology Command 50 Syntax 50 Description 50 Example 51 showunhealthy Command 53 Sun Datacenter InfiniBand Switch 36 Command Refer
68. atus Syntax checkpower 8 Sun Datacenter InfiniBand Switch 36 Command Reference April 2011 Description This hardware command checks the status of the power supplies Output is a simplified OK The checkpower command is available from the SYS Switch_Diag and SYS Fabric_Mgmt Linux shell targets of the Oracle ILOM CLI interface Example The following example shows how to check the power supply status with the checkpower command checkpower PSU 0 present status OK PSU 1 present status OK All PSUs OK Related Information m checkvoltages Command on page 11 m env_test Command on page 24 m Linux Shells for Hardware Commands on page 3 checktopomax Command Displays size of topology Syntax checktopomax h 1 v Understanding Hardware Commands 9 Description This hardware command is a script that verifies if the number of switches and HCAs found in the InfiniBand fabric is less than the maximum values provided in the conf desmonitor conf file The checktopomax command is available from the SYS Fabric_Mgmt Linux shell target of the Oracle ILOM CLI interface Options The following table describes the options to the checktopomax command and their purposes Option Purpose h Provides help 1 Disables writing output to Syslog v Verbose mode Example The following example shows how to verify the number of switches and HCAs within your InfiniBand
69. atus LEDs Syntax usr local util chassis_led on off green yellow white Description This hardware command monitors and controls the state of the chassis LEDs If no on or off option is specified the command displays the current state of the chassis LEDs Options The following table describes the options to the chassis_led command and their purposes Option Purpose on Turns the specified color LEDs on off Turns the specified color LEDs off green The OK LED yellow The Attention LED white The Locator LED Understanding Hardware Commands 5 Example The following example shows how to display the status of the chassis LEDs with the chassis_led command chassis led LED values Green on Yellow off White off Related Information m Switch User s Guide understanding the LEDs checkboot Command Displays switch chip boot status Syntax checkboot Description This hardware command checks the boot status of the switch chip Output is a simplified OK The checkboot command is available from the SYS Switch_Diag and SYS Fabric_Mgmt Linux shell targets of the Oracle ILOM CLI interface 6 Sun Datacenter InfiniBand Switch 36 Command Reference April 2011 Example The following example shows how to check the boot status of the switch chip with the checkboot command checkboot Switch OK Related Information m ibdevreset Command on page 34 m
70. bles that support the object identifier For example to securely display a table of information about the current local users on the management controller with IP address of 123 45 67 89 snmpwalk v3 u usersnmp 1 authPriv a MD5 A authpass x DES X privpass 123 45 67 89 SUN ILOM CONTROL MIB ilomCtrlLocalUserTable Related Information m SUN DCS MIB MIB OID Command Syntax on page 129 m SUN PLATFORM MIB MIB OID Command Syntax on page 153 m ENTITY MIB MIB OID Command Syntax on page 164 NTP OIDs The following table lists network time protocol object identifiers supported by the SUN ILOM CONTROL MIB MIB Description of Task or Activity Action MIB OID Display or set the IP address of the first NTP read ilomCtr1lDeviceNTPServerOneIP server used by the device write Display or set the IP address of the second NTP read ilomCtrlDeviceNTPServerTwoIP server used by the device write Related Information m OID Tables Overview on page 127 m SUN ILOM CONTROL MIB MIB OID Command Syntax on page 143 144 Sun Datacenter InfiniBand Switch 36 Command Reference April 2011 Remote Syslog OIDs The following table lists remote syslog object identifiers supported by the SUN ILOM CONTROL MIB MIB Description of Task or Activity Action MIB OID Display or set the IP address of the first remote read ilomCtrlRemoteSyslogDest1 syslog destination log host
71. cal State INIT I gt 25 As o SS a a a r I No bad Links with logical state INIT were found I E E E E NEEE EE E a ir aa au E E EE eS I PM Counters Info I Se NEEE EE E E NEE E ee EEE EEE E EEN EEEE E EE EOE I No illegal PM counters values were found I A AAA E N E E NE a E I Links With links width 4x as set by lw option I Sah samt ap chan A A E E E aa gi hc a a ic Wa e A a E nm E nh Sse a N ac E ss a ea I No unmatched Links with width 4x were found I A A ri EE E EE ec EE E EE EE A L E a E a i ee I Links With links speed 10 as set by ls option I A A E A A A A A a E I No unmatched Links with speed 10 were found I AA ASA A A A E E E E EE EEE EEE I Fabric Partitions Report see ibdiagnet pkey for a full hosts list I Subnet IPv4 PKey 0x7fff OKey 0x00000b1b MTU 2048Byte rate 10Gbps SL 0x00 W No members found for group I Bad Links Info I No bad link were found I Stages Status Report STAGE Errors Warnings Bad GUIDs LIDs Check Link State Active Check Performance Counters Report Specific Link Width Check Specific Link Speed Check Partitions Check IPoIB Subnets Check 0 Please see tmp ibdiagnet log for complete log ROOOOOO I Done Run time was 2 seconds Related Information m ibdiagnet man page m ibdiagpath Command on page 87 m Linux Shells for InfiniBand Commands on page 59 86 Sun Datacenter InfiniBand Switch 36 Command Reference Ap
72. cast packets read received from all virtual lanes on the port ibPmaPortMulticastRcvPkts Display a mapping of external PMA InfiniBand read device port to connector ibPmaExtPortConnector Related Information a OID Tables Overview on page 127 m SUN DCS MIB MIB OID Command Syntax on page 129 Understanding SNMP Trap OIDs SNMP trap object identifiers are provided in these tables a Trap Control OIDs on page 138 m Trap Threshold OIDs on page 138 a Trap Notification OIDs on page 140 Related Information 2 OID Tables Overview on page 127 S U U Y nderstanding Performance Manager Agent OIDs on page 134 UN HW TRAP MIB MIB OIDs on page 141 nderstanding the SUN ILOM CONTROL MIB MIB OIDs on page 142 nderstanding the SUN PLATFORM MIB MIB OIDs on page 153 nderstanding the ENTITY MIB MIB OIDs on page 163 Understanding SNMP MIB OIDs 137 Trap Control OIDs The following table lists trap control object identifiers supported by the SUN DCS MIB MIB Description of Task or Activity Action MIB OID Display or set the state whether performance read ibSnmpPerfCountersTrapEnable counters traps are generated write Display or set whether master Subnet Manager read ibSnmpMasterSMTrapEnable traps are generated write Display or set whether link state and speed read ibSnmpLinkTrapEnable traps are generated write Display or set
73. d also indicates if the fan is not present or has stopped The getfanspeed command is available from the SYS Switch_Diag and SYS Fabric_Mgmt Linux shell targets of the Oracle ILOM CLI interface Example The following example shows how to display fan speeds with the getfanspeed command getfanspeed Fan Fan Fan Fan Fan 0 un bP not present running at rpm 11212 running at rpm 11313 running at rpm 11521 not present Related Information m env_test Command on page 24 m Linux Shells for Hardware Commands on page 3 getmaster Command Displays primary or master Subnet Manager node information Understanding Hardware Commands 29 Syntax getmaster 1 Description This hardware command returns information about the node that hosts the primary or master Subnet Manager of the InfiniBand fabric The 1 option provides a short historical list of Subnet Manager activity The getmaster command is available from the SYS Switch_Diag and SYS Fabric_Mgmt Linux shell targets of the Oracle ILOM CLI interface Example The following example shows how to display information about the node that hosts the master Subnet Manager with the getmaster command getmaster 1 Local SM enabled and running Last ring buffer history listed 20100824 20 35 43 whereismaster started 20100824 20 35 44 Master SubnetManager on 20100824 20 36 01 Master SubnetManager on SUN DCS 36P QDR nsn34 170 2
74. d are unavailable from the SYS Switch_Diag or SYS Fabric_Mgmt targets Command SYS Switch_Diag SYS Fabric_Mgmt checkboot Available Available checkguidfilesftree Available checkpower Available Available checktopomax Available checkvoltages Available Available connector Available Available desport Available Available disablecablelog Available Understanding Hardware Commands 3 4 Command SYS Switch_Diag SYS Fabric_Mgmt disablelinklog disablesm disableswitchport enablecablelog enablelinklog enablesm enableswitchport env_test Available exit Available generatetopology getfanspeed Available getmaster Available getportstatus Available help Available listlinkup Available matchtopology setcontrolledhandover setsmpriority setsubnetprefix showfruinfo Available showpsufru Available showsmlog Available showtemps Available showtopology Available showunhealthy Available smconfigtest version Available Available Available Available Available Available Available Available Available Available Available Available Available Available Available Available Available Available Available Available Available Available Available Available Available Available Available Available Related Information m Linux Shells for InfiniBand Commands on page 59 Sun Datacenter InfiniBand Switch 36 Command Reference April 2011 chassis led Command Displays and controls chassis st
75. des Command Displays InfiniBand nodes in topology Syntax ibnodes h topology C ca_name P ca_port t timeout where Understanding InfiniBand Commands 97 m topology is the topology file m ca_name is the channel adapter name m ca_port is the channel adapter port m timeout is the timeout in milliseconds Description This InfiniBand command is a script that discovers the InfiniBand fabric topology or uses the existing topology file to extract the InfiniBand nodes of the channel adapters switches and routers The ibnodes command is available from the SYS Switch_Diag and SYS Fabric_Mgmt Linux shell targets of the Oracle ILOM CLI interface Options The following table describes the options to the ibnodes command and their purposes Option Purpose h Provides help C Uses the specified channel adapter name P Uses the specified channel adapter port t Overrides the default timeout Example The following example shows how to display the node GUIDs with the ibnodes command Note The output for your InfiniBand fabric will differ from that in the example ibnodes Ca 0x0003ba000100e388 ports 2 nsn33 43 HCA 1 Switch 0x0021283a8389a0a0 ports 36 Sun DCS 36 QDR switch localhost enhanced port 0 lid 15 Imc 0 98 Sun Datacenter InfiniBand Switch 36 Command Reference April 2011 Related Information ibnodes man page ibnetdiscover Command on page 92
76. ds are available through the Oracle ILOM CLI interface with the SYS Fabric_Mgmt target A smaller set of commands are available for monitoring purposes with the SYS Switch_Diag target See Linux Shells for InfiniBand Commands on page 59 With the standard Linux shell CLI interface only the root user of the management controller can run all of the InfiniBand commands The format of the InfiniBand commands is typically as follows command option option Command Syntax Links ibaddr d D G 1 g C ca_name P ca_port t ibaddr Command on timeout V h lid dr_path guid page 60 ibcheckerrors h b v N topology C ca_name P ca_port t ibcheckerrors timeout ibchecknet h N topology C ca_name P ca_port t timeout ibchecknode h v N G C ca_name P ca_port t timeout lid dr_path guid ibcheckport h v N G C ca_name P ca_port t timeout lid guid port ibcheckportstate G h N v C ca_name P ca_port t timeout lid guid port ibcheckportwidth G h N v C ca_name P ca_port t timeout lid guid port ibcheckstate h N v fopology C ca_name P ca_port t timeout ibcheckwidth h N v fopology C ca_name P ca_port t timeout Command on page 62 ibchec page 64 ibchec on page 66 ibchec on page 67 ibchec knet Command on kn
77. e m ibnetdiscover Command on page 92 m ibnodes Command on page 97 m Linux Shells for InfiniBand Commands on page 59 ibnetdiscover Command Discovers the InfiniBand topology Syntax ibnetdiscover d e v s 1 g H S R C ca_name P ca_port t timeout V node name map map p h topology where m ca_name is the channel adapter name m ca_port is the channel adapter port m timeout is the timeout in milliseconds a map is the file name of the node name map m topology is the topology file Description This InfiniBand command performs InfiniBand fabric discovery and outputs a human readable topology file Nodes node types node descriptions links port numbers port LIDs and GUIDs are displayed The output is directed to a topology file if the file name is specified 92 Sun Datacenter InfiniBand Switch 36 Command Reference April 2011 The output of the topology file follows this basic format for each node vendid vendor_ID_in_hex devid device _ID_in_hex and sysimgguid GUID_in_hex and or switchguid GUID_in_hex portGUID_in_hex Switch ports_total type nodeGUID_in_hex NodeDescription base port 0 lid LID Imc 0 or caguid GUID_in_hex Ca ports_total type nodeGUID_in_hex NodeDescription and port type nodeGUID_in_hex port portGUID_in_hex NodeDescription lid LID widthspeed port type nodeGUID_in_hex port portGUID_in_hex N
78. eckportstate Command on page 69 m ibnetdiscover Command on page 92 ibcheckwidth Command Finds 1x links in the InfiniBand fabric Syntax ibcheckwidth h N v topology C ca_name P ca_port t timeout where m topology is the topology file m ca_name is the channel adapter name m ca_port is the channel adapter port a timeout is the timeout in milliseconds Description This InfiniBand command is a script that uses the topology file created by the ibnetdiscover command The script scans the InfiniBand fabric to validate Active link widths and report the links that are 1x links 74 Sun Datacenter InfiniBand Switch 36 Command Reference April 2011 Options The following table describes the options to the ibcheckwidth command and their purposes Option Purpose h Provides help N Uses mono mode instead of color mode v Provides verbose output C Uses the specified channel adapter name P Uses the specified channel adapter port Overrides the default timeout Example The following example shows how to check the 1x links for all ports with the ibcheckwidth command Note The output for your InfiniBand fabric will differ from that in the example ibcheckwidth v Checking Switch nodeguid 0x0021283a8389a0a0 Node check lid 15 OK Port check lid 15 port 23 OK Port check lid 15 port 19 OK Port check lid 15 port 17 OK Checking Ca nodeguid 0x0003ba00010
79. eference April 2011 Option Purpose U Returns the name of the specified GUID G Uses the port GUID address Displays the Subnet Administrator class port information s Returns the PortInforRecords with the isSM or isSMdisabled capability mask bit enabled g Displays multicast group information m Displays multicast member information If a group is specified provides only the GUID and node description for each entry x Displays LinkRecord information src to dst Displays a PathRecord for source destination where source and destination are either node names or LIDs sgid to dgid Displays a PathRecord for source destination where source and destination are GIDs in an IPv6 format acceptable to inet_pton C Uses the specified channel adapter name P Uses the specified channel adapter port t Overrides the default timeout Example The following example shows how to produce a node record dump of every LID in the InfiniBand fabric with the saquery command Note The output in the example is a portion of the full output saquery NodeRecord dump reserved base_version class_version node_type port_guid partition_cap device_id revision Understanding InfiniBand Commands 119 Vendor lia tiee eia 0x2C9 NodeDescription nsn33 43 HCA 1 NodeRecord dump USI ous eet eames te E S ae cet E tated OxF reserved 0x0 Related Information m saq
80. ence April 2011 Syntax 53 Description 53 Example 54 smconfigtest Command 54 Syntax 54 Description 54 Options 55 Example 55 version Command Hardware 55 Syntax 55 Description 55 Example 56 Understanding InfiniBand Commands 57 Linux Shells for InfiniBand Commands 59 ibaddr Command 60 Syntax 61 Description 61 Options 61 Example 62 ibcheckerrors Command 62 Syntax 62 Description 63 Options 63 Example 63 ibchecknet Command 64 Syntax 64 Description 64 Options 65 Contents ix Example 65 ibchecknode Command 66 Syntax 66 Description 66 Options 67 Example 67 ibcheckport Command 67 Syntax 68 Description 68 Options 68 Example 69 ibcheckportstate Command 69 Syntax 69 Description 70 Options 70 Example 70 ibcheckportwidth Command 71 Syntax 71 Description 71 Options 71 Example 72 ibcheckstate Command 72 Syntax 72 Description 73 Options 73 Example 73 ibcheckwidth Command 74 Syntax 74 x Sun Datacenter InfiniBand Switch 36 Command Reference April 2011 Description 74 Options 75 Example 75 ibclearcounters Command 76 Syntax 76 Description 76 Options 77 Example 77 ibclearerrors Command 77 Syntax 77 Description 78 Options 78 Example 78 ibdatacounters Command 79 Syntax 79 Description 79 Options 79 Example 80 ibdatacounts Command 80 Syntax 80 Description 81 Options 81 Example 82 ibdiagnet Command 82 Syntax 82 Description 83 Options 84 Example 85 Contents
81. ent when a change in LinkState LinkSpeedActive or LinkWidthActive happens on a port This trap is sent when error rate on a port is high according to the configured values ibSnmpLinkTrap ibSnmpHighErrRateTrap Related Information a OID Tables Overview on page 127 m SUN DCS MIB MIB OID Command Syntax on page 129 SUN HW TRAP MIB MIB OIDs The following table lists hardware trap configuration object identifiers supported by the SUN HW TRAP MIB MIB Description of Task or Activity Action MIB OID Display or set the text string used to identify the read sunHwTrapSystemIdentifier source of the trap Typically the host name Display the name of the component which is the read sunHwTrapComponentName source of the trap Display the threshold type that the sensor is read sunHwTrapThresholdType reporting Display the threshold value that has been read sunHwTrapThresholdValue exceeded Display the threshold sensor s reading at the read sunHwTrapSensorValue time of the trap Display or set an optional description which read sunHwTrapAdditionalInfo provides additional information Display the object in the entPhysicalTableto read sunHwTrapAssocObjectId which the notification applies Display an indication of the severity of the read sunHwTrapSeverity notification Understanding SNMP MIB OIDs 141 Description of Task or Activity Action MIB OID D
82. env_test Command on page 24 m Linux Shells for Hardware Commands on page 3 checkguidfilesftree Command Performs check of Ftree GUID files Syntax checkguidfilesftree h q v Description This hardware command is a script that performs a search for and check of the root node GUID file used for the Ftree routing algorithm The command searches the etc opensm opensm conf file for the specified root node GUID filename and checks the integrity of that file The file is typically the etc opensm guid txt file This command is only useful for InfiniBand fabrics using the Ftree routing algorithm The checkguidfilesftree command is available from the SYS Fabric_Mgmt Linux shell target of the Oracle ILOM CLI interface Understanding Hardware Commands 7 Options The following table describes the options to the generic command and their purposes Option Purpose h Provides help q Disables output unless errors are detected v Verbose mode Example The following example shows how to check for the root node GUID file with the checkguidfilesftree command checkguidfilesftree v From etc opensm opensm conf file routing_engine explains ftree root_guid_file given null checkguidfilesftree INFO root file not specified null Can not investigate further Related Information m Linux Shells for Hardware Commands on page 3 checkpower Command Displays power supply st
83. erver Module SUNDCS36QDR Sun Datacenter InfiniBand Switch 36 SUNDCS72QDR Sun Datacenter InfiniBand Switch 72 m SUNDCS648QDR Sun Datacenter InfiniBand Switch 648 SUNIBQDRGW Sun Network QDR InfiniBand Gateway Switch m 4 GEN ERIC An I4 switch chip m device_name is the node description of the device the hostname and number or the modified GUID 50 Sun Datacenter InfiniBand Switch 36 Command Reference April 2011 m panel_label is the name of the connector hard wire link or port as defined by the ibn1 files For example C 6A is connector 6A BX1 is BridgeX slice 1 A SW is switch chip A and P1 is port 1 m link_status is one of the following a 1x 2 5G single data rate SDR a 2x 5G dual data rate DDR a 4x 10G quad data rate QDR m connected_device_type is the device type at the other end of the link m connected_device_name is the name of the device at the other end of the link m connected_panel_label is the name of the connector or port at the other end of the link For example SUNDCS36QDR nsn34 170 C 17A 4x 10G gt SUNDCS36QDR nsn34 170 C 17B C 17B 4x 10G gt SUNDCS36QDR nsn34 170 C 17A C 16A 4x 10G gt SUNDCS36QDR nsn34 170 C 16B C 16B 4x 10G gt SUNDCS36QDR nsn34 170 C 16A The showtopology command is available from the SYS Switch_Diag and SYS Fabric_Mgmt Linux shell targets of the Oracle ILOM CLI interface Example The following example
84. es ae eee ew ESAS 23 CounterSelects ce cocinera Ox1b01 SVMDOLEF LOLS is 0 LinkReEcovers Tati oS 0 LinkDowned rai e ra a das ak 0 ROVEELOES Vii e si 0 RevRemotePhysErrorS t oooo o 0 RevSwRelayElTTOYS ooooooooo o o 0 XMEDISCATAS E uo inde ees 0 XmtConstraintErrors 0 RevConstraintErrors 0 LinkIntegrityErrors 0 ExcBufOverrunErrors 0 VELIDEOPPEdi ii ee tek 0 RMCDACAL oases ge Gee A Be ee Sw btw Glee te 20232 REVDALA Ss oie eG aE A Sew es FS 20232 AME PKU 2d PA da octs 281 REVPKUS 2 Siw ida 281 Sun Datacenter InfiniBand Switch 36 Command Reference April 2011 Related Information saquery Command perfquery man page ibcheckerrors Command on page 62 ibdatacounters Command on page 79 ibdatacounts Command on page 80 Linux Shells for InfiniBand Commands on page 59 Queries InfiniBand fabric administration attributes Syntax saquery h d p N D S I I L 1 G 0 U c s g m x C ca_name P ca_port t timeout src to dst source destination sgid to dgid source destination name lid guid where m ca_name is the channel adapter name ca_port is the channel adapter port timeout is the timeout in milliseconds lid is the local identifier guid is the global unique identifier name is the query name described in the following table Query Na
85. esm 17 disableswitchport 18 enablecablelog 20 enablelinklog 20 enablesm 21 enableswitchport 22 env_test 24 exit 26 generatetopology 27 getfanspeed 28 getmaster 29 getnm2type 30 getportstatus 31 help 32 ibdevreset 34 listlinkup 35 managementreset 36 matchtopology 37 setcontrolledhandover 38 setloghost 40 setmsmlocationmonitor 41 setsmpriority 42 setsubnetprefix 44 showfruinfo 45 showpsufru 46 showsmlog 47 showtemps 49 showtopology 50 showunhealthy 53 smconfigtest 54 version 55 InfiniBand 57 ibaddr 60 ibcheckerrors 62 ibchecknet 64 ibchecknode 66 ibcheckport 67 ibcheckportstate 69 ibcheckportwidth 71 ibcheckstate 72 ibcheckwidth 74 ibclearcounters 76 ibclearerrors 77 ibdatacounters 79 ibdatacounts 80 ibdiagnet 82 ibdiagpath 87 ibhosts 90 ibnetdiscover 92 ibnetstatus 95 ibnodes 97 ibportstate 99 ibroute 101 ibrouters 104 ibstat 105 ibstatus 107 167 ibswitches 109 ibsysstat 110 ibtracert 112 perfquery 114 saquery 117 sminfo 120 smpdump 122 smpquery 124 connector command 12 D desport command 14 disablecablelog command 15 disablelinklog command 16 disablesm command 17 disableswitchport command 18 E enablecablelog command 20 enablelinklog command 20 enablesm command 21 enableswitchport command 22 ENTITY MIB MIB OIDs 163 OID command syntax 164 physical entity OIDs 165 env_test command 24 exit command 26
86. et Manager fails the secondary and standby Subnet Manager takes on the role of the new master Subnet Manager During this time traffic is temporarily suspended as the secondary and master Subnet Manager discovers and sets up the InfiniBand fabric If the primary Subnet Manager is able to recover from the failure reboot and reinitialize itself it identifies itself as the intended master Subnet Manager Again traffic is temporarily suspended as the primary and master Subnet Manager re discovers and sets up the InfiniBand fabric The secondary Subnet Manager returns to the standby status If controlled handover is enabled then some priority values become reserved The Subnet Managers dynamically adjust their respective priorities to avoid the dual handover situation A secondary Subnet Manager that became a master Subnet Manager due to a handover raises its priority to a reserved value and retains its master Subnet Manager status Regardless if the primary Subnet Manager comes back online the second handover does not occur The user configured priorities of the Subnet Managers are retained only during a handover are reserved priorities used The result of this scheme is that the user configured priority is respected during system boot but dual handover does not occur because the primary Subnet Manager loses its master Subnet Manager status secondary Subnet Manager priority changes to reserve Note Manually starting Subnet Managers i
87. etsubnetprefix command is available from the SYS Fabric_Mgmt Linux shell target of the Oracle ILOM CLI interface Example The following example shows how to set the subnet prefix with the setsubnetprefix command setsubnetprefix Oxabbababe Related Information m enablesm Command on page 21 m setcontrolledhandover Command on page 38 m setsmpriority Command on page 42 m Linux Shells for Hardware Commands on page 3 showfruinfo Command Displays chassis FRU information Syntax showfruinfo Description This hardware command displays the contents of the chassis FRU ID registers Understanding Hardware Commands 45 The showfruinfo command is available from the SYS Switch_Diag and SYS Fabric_Mgmt Linux shell targets of the Oracle ILOM CLI interface Example The following example shows how to display the chassis FRU ID registers with the showfruinfo command showfruinfo UNIX_Timestamp32 Fri Apr 16 16 42 09 2010 Sun_Fru_Description ASSY NM2 36P Vendor_ID_Code 01 2C Vendor_ID_Code_Source 01 Vendor_Name_And_Site_Location Celestica San Jose Sun_Part_Number 5111232 Sun_Serial_Number 0110S7C 0945NG0036 Serial_Number_Format 4V3F1 2Y2W2X4S Initial_HW_Dash_Level 06 Initial_HW_Rev_Level 01 Sun_Fru_Shortname NM2 36 ports Sun_Hazard_Class_Code gt 4 Sun_SpecPartNo 885 1507 06 Related Information m showpsufru Command on page 46 m Linux
88. exceeded Display or set whether a trap is generated read ibSnmpPerfPortXmitDiscardThreshold should the PortXmitDiscards threshold write be exceeded Display or set whether a trap is generated read ibSnmpPerfPortXmitConstraintErrThreshold should the PortXmitConstraintErr write threshold be exceeded Display or set whether a trap is generated read ibSnmpPerfPortRcvConstraintErrThreshold should the PortRcvConstraintErr write threshold be exceeded Display or set whether a trap is generated read ibSnmpPerfLocalLinkIntegrityErrThreshold should the LocalLinkIntegrityErr write threshold be exceeded Display or set whether a trap is generated read ibSnmpPer fExcessBufOverrunErrThreshold should the ExcessBufOverrunErr write threshold be exceeded Display or set whether a trap is generated read ibSnmpPerfV115DroppedThreshold should the V115Dropped threshold be write exceeded Related Information m OID Tables Overview on page 127 m SUN DCS MIB MIB OID Command Syntax on page 129 Understanding SNMP MIB OIDs 139 Trap Notification OIDs The following table lists trap notification object identifiers supported by the SUN DCS MIB MIB Description of Task or Activity Action MIB OID Display an index of InfiniBand nodes read ibSnmpTrapNodeIndex originating a trap Display an index of InfiniBand data ports read ibSnmpTrapPort Index originating a trap
89. fabric with the checktopomax command Note The output for your InfiniBand fabric will differ from that in the example checktopomax v checktopomax INFO You have allowed max number of Switch elements to be 48 checktopomax INFO You have allowed max number of CA elements to be 1500 checktopomax INFO Number of Switch elements empiric found by application usr sbin ibnodes 2 checktopomax INFO Number of Ca elements empiric found by application usr sbin ibnodes 7 Related Information m ibnodes Command on page 97 m ibhosts Command on page 90 10 Sun Datacenter InfiniBand Switch 36 Command Reference April 2011 m Linux Shells for Hardware Commands on page 3 checkvoltages Command Verifies voltages Syntax checkvoltages Description This hardware command displays the internal voltages for the main board On the left side of the equals sign is the expected voltage On the right side of the equals sign is the measured voltage If the difference between the expected voltage and the measured voltage is more than 10 the cause should be investigated The command also provides a summary of the voltage conditions The checkvoltages command is available from the SYS Switch_Diag and SYS Fabric_Mgmt Linux shell targets of the Oracle ILOM CLI interface Example The following example shows how to check that voltages are at nominal values with the checkvoltages command c
90. finiBand path Sun Datacenter InfiniBand Switch 36 Command Reference April 2011 680 680 680 680 Syntax ibtracert d D G h m mlid s smlid v v c ca_name P ca_port t timeout lid dr_path guid startlid endlid where a mlid is the multicast LID m smlid is the Subnet Manager LID m ca_name is the channel adapter name m ca_port is the channel adapter port m timeout is the timeout in milliseconds m lid is the local identifier m dr_path is the directed path m guid is the global unique identifier m startlid is the starting LID for a range m endlid is the ending LID for a range Description This InfiniBand command uses SMPs to trace the path from a source GID or LID to a destination GID or LID Each responding hop in the path is displayed The m option enables multicast path tracing between source and destination nodes The ibtracert command is available from the SYS Switch_Diag and SYS Fabric_Mgmt Linux shell targets of the Oracle ILOM CLI interface Options The following table describes the options to the ibtracert command and their purposes Option Purpose d Sets the debug level Can be used several times to increase the debug level D Uses the directed path address The path is a comma delimited sequence of out ports G Uses the port GUID address h Provides help Understanding InfiniBand Commands 113 Option Purpose m Shows t
91. g table describes the options to the smodump command and their purposes Option Purpose D Uses the directed path address The path is a comma delimited sequence of out ports e Displays send and receive errors g Shows the GID address only h Provides help V Displays the version information C Uses the specified channel adapter name P Uses the specified channel adapter port E Overrides the default timeout Example The following example shows how to display a raw dump of the InfiniBand management attributes for the directed path through LIDs 14 and 15 with the smpdump command smpdump 14 15 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 SMP status Oxc Related Information m smpdump man page Understanding InfiniBand Commands 123 m smpquery Command on page 124 smpquery Command Queries InfiniBand fabric management attributes Syntax smpquery d 1 D e G h v V C ca_namel P ca_port t timeout op lid dr_path guid params where m ca_name is the channel adapter name m ca_port is the channel adapter port a timeout is the timeout in milliseconds m op is the supported operation m lid is the local identifier m dr_path is the directed path m guid is the global unique identifier m params is the parameter of the
92. ging of link events to the Syslog The enablelinklog command is available from the SYS Fabric_Mgmt Linux shell target of the Oracle ILOM CLI interface Example The following example shows how to enable logging of link events to the Syslog with the enablelinklog command enablelinklog Stopping Environment daemon OK Starting Environment daemon OK Related Information m disablelinklog Command on page 16 m enablecablelog Command on page 20 m Linux Shells for Hardware Commands on page 3 enablesm Command Enables the Subnet Manager within the management controller Syntax enablesm Understanding Hardware Commands 21 Description This hardware command enables the OpenSM opensmd daemon on the management controller Note Similarly both the enablesm and opensm commands invoke an instance of the same Subnet Manager Conversely the enablesm command merely starts the Subnet Manager while the opensm command can configure the Subnet Manager The enablesm command initiates an instance of the opensmd daemon The daemon reads the etc opensm opensm conf configuration file upon startup which it uses to configure the OpenSM Subnet Manager The enablesm command is more user friendly because it is not necessary to provide command line options and arguments The enablesm command is available from the SYS Fabric_Mgmt Linux shell target of the Oracle ILOM CLI interface Example T
93. gt SUNDCS36QDR nsn34 170 DCS36QDR nsn34 170 DCS36QDR nsn34 DCS36QDR nsn34 DCS36QDR nsn34 DCS36QDR nsn34 DCS36QDR nsn34 DCS36QDR nsn34 DCS36QDR nsn34 EV26418_02P nsn34 DEV26418_02P nsn34 DEV26418_02P nsn34 DEV26418_02P nsn34 C 0B 4x 10G gt DEV26418_02P nsn34 45_HCA 1 P2 C 0A 4x 10G gt DEV26418_02P nsn34 45_HCA 1 P1 C 1B 4x 10G gt SUNDCS360DR nsn34 170 C 1A C 1A 4x 10G gt SUNDCS360DR nsn34 170 C 1B C 2B 4x 10G gt SUNDCS360DR nsn34 170 C 2A C 2A 4x 10G gt SUNDCS360DR nsn34 170 C 2B C 3B 4x 10G gt SUNDCS360DR nsn34 170 C 3A DCS36QDR nsn34 170 C 3B C 4B 4x 10G gt SUNDCS360DR nsn34 170 C 4A C 4A 4x 10G gt SUNDCS36QDR nsn34 170 C 4B C 5B 4x 10G gt SUNDCS360DR nsn34 170 C 5A C 5A 4x 10G gt SUNDCS360DR nsn34 170 C 5B DCS36QDR nsn34 170 C 14B C 7A 4x 10G gt SUNDCS36QDR nsn34 170 C 7B C 7B 4x 10G gt SUNDCS36QDR nsn34 170 C 7A C 6A 4x 10G gt SUNDCS36QDR nsn34 170 C 9B C 6B 4x 10G gt DEV26418_02P nsn33 59_HCA 1 P1 170 C 16B 170 C 16A 170 C 15B 170 C 15A 170 C 13A 170 C 8A 170 C 14A 39_HCA 1 P2 39_HCA 1 P1 41_HCA 1 P1 44 HCA 1 P2 42_HCA 1 P1 41_HCA 1 P2 42_HCA 1 P2 C 11B C 12B C 6B C 9A C 10B C 10A C 11A Sun Datacenter InfiniBand Switch 36 Command Reference April 2011 DEV26418_02P nsn34 39_HCA 1 P1 4x 10G gt SUNDCS36QDR nsn34 170 C 12A P2 4x 10G gt SUNDCS36QDR nsn34 170 C 13B Created from nsn34 170 at Wed Sep 8
94. he following example shows how to enable the opensmd daemon with the enablesm command enablesm Starting IB Subnet Manager OK Starting partitiond daemon OK Related Information m disablesm Command on page 17 m setsmpriority Command on page 42 m Linux Shells for Hardware Commands on page 3 enableswitchport Command Enables a connector or switch chip port 22 Sun Datacenter InfiniBand Switch 36 Command Reference April 2011 Syntax enableswitchport reason reason connector Sw where m reason is the reason for disabling the port Blacklist m connector is the number of the QSFP connector 0A 171 m port is the number of the port 1 36 Description itch port or Partition B This hardware command enables a QSFP connector and port on the switch chip The command addresses either the connector or the port on the switch chip Blacklist The reason option enables you to use the 1 or Partition passphrases to unlock the state of the port as locked using the disableswitchport command Note State changes made with the ibportstate command are not recognized by the disableswitchport enableswitchport or listlinkup commands The enableswitchport command is available from the shell target of the Oracle ILOM CLI interface Example SYS Fabric_Mgmt Linux The following example shows how to enable and de blacklist connector 14A with the en
95. he multicast trace of the specified MLID s Uses smlid as the target LID for Subnet Manager or Subnet Administrator queries v Provides verbose output V Displays the version information C Uses the specified channel adapter name P Uses the specified channel adapter port E Overrides the default timeout Example The following example shows how to display the path from LID 25 to LID 24 with the ibtracert command Note The output for your InfiniBand fabric will differ from that in the example ibtracert 15 14 From switch 0x0021283a8389a0a0 portnum 0 lid 15 15 Sun DCS 36 QDR switch localhost 23 gt ca port 0x0003ba000100e38a 2 lid 14 14 nsn33 43 HCA 1 To ca 0x0003ba000100e388 portnum 2 lid 14 14 nsn33 43 HCA 1 Related Information m ibtracert man page m ibroute Command on page 101 m Linux Shells for InfiniBand Commands on page 59 perfquery Command Queries InfiniBand port counters 114 Sun Datacenter InfiniBand Switch 36 Command Reference April 2011 Syntax perfquery d e G h a 1 r R v V C ca_name P ca_port t timeout lid guid port reset_mask where m ca_name is the channel adapter name m ca_port is the channel adapter port m timeout is the timeout in milliseconds m lid is the local identifier m guid is the global unique identifier m port is the port being queried m reset_mask is the two b
96. heckvoltages Voltage Measured Measured Measured Measured Measured Measured Measured ECB OK 3 3V Main 3 28 V 3 3V Standby 3 37 V 12V 12 06 V 5V 5 03 V VBAT 3 25 V 2 5V 2 52 V 1 8v 1 80 V Understanding Hardware Commands 11 Measured I4 1 2V 1 22 V All voltages OK Related Information a checkpower Command on page 8 m env_test Command on page 24 m Linux Shells for Hardware Commands on page 3 connector Command Reads OSFP cable information Syntax connector name present portstate info dump h where name is the name of the connector 0A 17B Description This hardware command performs a pass fail test to verify that an InfiniBand cable is connected to a particular connector and to the switch chip port that the link routes The command can also read the data registers of the cable and report FRU ID information The connector command is available from the SYS Switch_Diag and SYS Fabric_Mgmt Linux shell targets of the Oracle ILOM CLI interface 12 Sun Datacenter InfiniBand Switch 36 Command Reference April 2011 Options The following table describes the options to the connector command and their purposes Option Purpose present Checks for the presence of connector number portstate Returns a mapping of the connector to the respective port of the switch chip info Displays FRU ID information dump Displays a raw hexadecimal dump of
97. id guid port where m ca_name is the channel adapter name m ca_port is the channel adapter port m timeout is the timeout in milliseconds m lid is the local identifier m guid is the global unique identifier m port is the port being validated Understanding InfiniBand Commands 69 Description This InfiniBand command checks the specified port for the logical Active and physical LinkUp states Note The port address is a LID unless the G option is used to specify a GUID address Options The following table describes the options to the ibcheckportstate command and their purposes Option Purpose G Uses the port GUID address h Provides help N Uses mono mode instead of color mode C Uses the specified channel adapter name P Uses the specified channel adapter port s Overrides the default timeout Example The following example shows how to check port 23 on LID 15 with the ibcheckportstate command ibcheckportstate v 15 23 Port check lid 15 port 23 OK Related Information m ibcheckportstate man page m getportstatus Command on page 31 m ibaddr Command on page 60 a smpquery Command on page 124 70 Sun Datacenter InfiniBand Switch 36 Command Reference April 2011 ibcheckportwidth Command Validates InfiniBand ports for 1x link width Syntax ibcheckportwidth v G h N C ca_name P ca_port t timeout lid guid port where
98. is the channel adapter name 90 Sun Datacenter InfiniBand Switch 36 Command Reference April 2011 m ca_port is the channel adapter port a timeout is the timeout in milliseconds Description This InfiniBand command is a script that discovers the InfiniBand fabric topology or uses the existing topology file to extract the channel adapter nodes The ibhosts command is available from the SYS Switch_Diag and SYS Fabric_Mgmt Linux shell targets of the Oracle ILOM CLI interface Options The following table describes the options to the ibhosts command and their purposes Option Purpose h Provides help C Uses the specified channel adapter name P Uses the specified channel adapter port t Overrides the default timeout Example The following example shows how to display the host node GUIDs with the ibhosts command Note The output in the example is a portion of the full output and varies for each InfiniBand topology ibhosts Ca 0x0003ba000100eE388 ports 2 nsn33 43 HCA 1 Ca 0x5080020000911310 ports 1 nsn32 20 HCA 1 Ca 0x50800200008e532c ports 1 ib 71 HCA 1 Ca 0x50800200008e5328 ports 1 ib 70 HCA 1 Ca 0x50800200008296a4 ports 2 ib 90 HCA 1 Ca 0x50800200008296a0 ports 2 ib 91 HCA 1 Understanding InfiniBand Commands 91 Ca 0x508002000082dc34 ports 1 ib 231 HCA 2 Ca 0x0144f6c666b50100 ports 2 nsn32 10 HCA 1 Related Information m ibhosts man pag
99. iscarded because the port is down or congested Display the number of packets not transmitted from the port because the packet is raw or fails partition key check or IP version check read read ibPmaPor ibPmaPor tXmitDiscard tXmitConstrain tErr Display the number of packets received on the port that are discarded because the packet is raw or fails partition key check or IP version check read ibPmaPor tRcevConstraintl BKET Display the number of times that the local physical errors threshold was exceeded read ibPmaLocalLinkIntegrityErr Understanding SNMP MIB OIDs 135 Description of Task or Activity Action MIB OID Display the number of times that buffer overrun read ibPmaExcessBufOverrunErr errors occurred Display the number of incoming VL 15 packets read ibPmaV115Dropped dropped due to lack of buffers Display a mapping of PMA InfiniBand device read ibPmaPortConnector port to connector Display the number of symbol errors for a port read ibPmaSymErrors10min during the last 10 minutes Display the number of symbol errors for a port read ibPmaSymErrorslhour during the last hour Display the number of symbol errors for a port read ibPmaSymErrors24hours during the last 24 hours Related Information a OID Tables Overview on page 127 m SUN DCS MIB MIB OID Command Syntax on page 129 PMA Extended Port Counters Table OIDs The fo
100. isplay the text string containing the chassis read sunHwTrapChassisId serial number Display the text string containing the product read sunHwTrapProductName name Display an indication as to why the component read sunHwTrapDisableReason was disabled Display or set the message used by the test trap read sunHwTrapTestMessage Related Information m OID Tables Overview on page 127 Understanding the Understanding the SUN DCS MIB MIB OIDs on page 128 Understanding the SUN ILOM CONTROL MIB MIB OIDs on page 142 Understanding the SUN PLATFORM MIB MIB OIDs on page 153 Understanding the ENTITY MIB MIB OIDs on page 163 SUN ILOM CONTROL MIB MIB OIDs This topic provides many tables of the Oracle ILOM object identifiers Tables of object identifiers are provided in the following topics m SUN ILOM CONTROL MIB MIB OID Command Syntax on page 143 NTP OIDs on page 144 Remote Syslog OIDs on page 145 HTTP OIDs on page 145 HTTPS OIDs on page 146 Network OIDs on page 146 User OIDs on page 148 Session OIDs on page 148 Event Log OIDs on page 149 Alert OIDs on page 150 Clock OIDs on page 151 142 Sun Datacenter InfiniBand Switch 36 Command Reference April 2011 m Backup and Restore OIDs on page 151 m Identification OIDs on page 152 SMTP OIDs on page 152 Related Information m OID Tables Overview
101. le of information about the current read ilomCtrlEventLogTable entries in the event log Display an integer representing the type of event read ilomCtrlEventLogType Display the date and time that the event log entry read ilomCtrlEventLogTimestamp was recorded Display an integer representing the class of event read ilomCtrlEventLogClass Display the event severity corresponding to the read ilomCtrlEventLogSeverity given log entry Display the description of the event read ilomCtrlEventLogDescription Clear the event log write ilomCtrlEventLogClear Related Information a OID Tables Overview on page 127 m SUN ILOM CONTROL MIB MIB OID Command Syntax on page 143 Understanding SNMP MIB OIDs 149 Alert OIDs The following table lists alert object identifiers supported by the SUN ILOM CONTROL MIB MIB Description of Task or Activity Action MIB OID Display a table of information used to view and read ilomCtrlAlertsTable add alert rules Display or set the minimum event severity read ilomCtrlAlertSeverity which should trigger an alert for a given class write Display or set the type of notification for a read ilomCtrlAlertType given alert write Display or set the IP address to receive alert read ilomCtrlAlertDestinationIP notifications when the alert type is write snmptrap 2 ipmipet 3 or remotesyslog 4 Display or set the email address to send alert read ilomCt
102. les Overview on page 127 m SUN PLATFORM MIB MIB OID Command Syntax on page 153 Physical Class Extension Table OIDs The following table lists physical class extension object identifiers supported by the SUN PLATFORM MIB MIB Description of Task or Activity Action MIB OID Display a table of information about the read sunPlatPhysicalTable physical class of the entity if it is classified as other 1 Display information about a piece of equipment read with an entPhysicalClass of other 1 Display possible physical classes where read entPhysicalClass is specified as other 1 sunPlatPhysicalEntry sunPlatPhysicalClass 156 Related Information m OID Tables Overview on page 127 m SUN PLATFORM MIB MIB OID Command Syntax on page 153 Sun Datacenter InfiniBand Switch 36 Command Reference April 2011 Sun Platform Sensor Table OIDs The following table lists sensor object identifiers supported by the SUN PLATFORM MIB MIB Description of Task or Activity Action MIB OID Display a table of attributes common to all read sunPlatSensorTable sensors Display information about a piece of equipment read with an entPhysicalClass of sensor 8 sunPlatSensorEntry Display possible sensor classes where read entPhysicalClass is specified as sensor 8 sunPlatSensorClass Display possible sensor types where read entPhysicalClass is specified as sensor 8 sunPlatSens
103. llowing table lists extended PMA port counter object identifiers supported by the SUN DCS MIB MIB Description of Task or Activity Action MIB OID Display a table of PMA extended port counters read ibPmaExtPortCntrsTable information Display a row of the read ibPmaExt PortCntrsEntry ibPmaExtPortCntrsTable Display an index of external PMA nodes read ibPmaExtPortCntrsNode Display an index of external PMA InfiniBand read ibPmaExtPortCntrsPort data ports Display the number of data octets divided by 4 read ibPmaPortXmitData transmitted on all virtual lanes from the port Display the number of data octets divided by 4 read ibPmaPortRcvData received on all virtual lanes at the port Display the number of packets transmitted on read ibPmaPortXmitPkts all virtual lanes from the port 136 Sun Datacenter InfiniBand Switch 36 Command Reference April 2011 Description of Task or Activity Action MIB OID Display the number of packets received from all read virtual lanes on the port ibPmaPortRcvPkts Display the number of unicast packets read transmitted on all virtual lanes from the port ibPmaPortUnicastXmitPkts Display the number of unicast packets received read from all virtual lanes on the port ibPmaPortUnicastRevPkts Display the number of multicast packets read transmitted on all virtual lanes from the port ibPmaPortMulticastXmitPkts Display the number of multi
104. m timeout is the timeout in milliseconds 72 Sun Datacenter InfiniBand Switch 36 Command Reference April 2011 Description This InfiniBand command is a script that uses the topology file created by the ibnetdiscover command The script scans the InfiniBand fabric to validate the port logical and physical states and reports any ports that have a logical state other than Active or a physical state other than LinkUp Options The following table describes the options to the ibcheckstate command and their purposes Option Purpose h Provides help N Uses mono mode instead of color mode v Provides verbose output c Uses the specified channel adapter name P Uses the specified channel adapter port St Overrides the default timeout Example The following example shows how to check the state of all ports with the ibcheckstate command Note The output for your InfiniBand fabric will differ from that in the example ibcheckstate v Checking Switch nodeguid 0x0021283a8389a0a0 Node check lid 15 OK Port check lid 15 port 23 OK Port check lid 15 port 19 OK Checking Ca nodeguid 0x0003ba000100e388 Node check lid 14 OK Port check lid 14 port 2 OK Understanding InfiniBand Commands 73 Summary 5 nodes checked 0 bad nodes found 10 ports checked 0 ports with bad state found Related Information m ibcheckstate man page m ibchecknode Command on page 66 m ibch
105. mand smpquery nodeinfo 15 Node info Lid 15 BaSseVerS resina ae BSR SR es 1 CLASSVEFS che eee hte ee wee eee de 1 NOGETYV DE Si Sad Ghar ES Switch NUMBOTES rta aan ee arate 36 SystemGuid oa Sees eck 0x0021283a8389a0a3 GU a 0x0021283a8389a0a0 POPEGUES teva ane eee Be Se we ee 0x0021283a8389a0a0 Partap aaa seca dade Tad icons 8 DOVE x acts doa bce a hob eee BB sic 0xbd36 REVISTA ls 0x000000a0 LOCAUPOL Es ici si oe 1 Vendor i tates oa Rae a ete se 0x0002c9 Related Information m smpquery man page m saquery Command on page 117 smpdump Command on page 122 m Linux Shells for InfiniBand Commands on page 59 Sun Datacenter InfiniBand Switch 36 Command Reference April 2011 Understanding SNMP MIB OIDs These topics provide tables of object identifiers OIDs for their respective management information bases MIBs a OID Tables Overview on page 127 m Understanding the SUN DCS MIB MIB OIDs on page 128 m SUN HW TRAP MIB MIB OIDs on page 141 m Understanding the SUN ILOM CONTROL MIB MIB OIDs on page 142 m Understanding the SUN PLATFORM MIB MIB OIDs on page 153 m Understanding the ENTITY MIB MIB OIDs on page 163 Related Information m Understanding Hardware Commands on page 1 Understanding InfiniBand Commands on page 57 OID Tables Overview Each OID table has three columns of information From left to right the c
106. mation about the Subnet Manager read smLocalSMRunning Disable or enable the Subnet Manager write Display the state of the Subnet Manager read smLocalSMState Related Information a OID Tables Overview on page 127 m SUN DCS MIB MIB OID Command Syntax on page 129 Subnet Manager Agent Data Port OIDs The following table lists SMA object identifiers supported by the SUN DCS MIB MIB Description of Task or Activity Action MIB OID Display a table of SMA PortInfo information read ibSmaPortInfoTable Display a row of the ibSmaPortInfoTable read ibSmaPortInfoEntry Display an index of SMA InfiniBand nodes read ibSmaNodeIndex Display an index of SMA InfiniBand data ports read ibSmaPort Index Display SMA enabled link width read ibSmaPortLinkWidthEnabled Display SMA supported link width read ibSmaPortLinkWidthSupported Display SMA currently active link width read ibSmaPortLinkWidthActive Display SMA supported link speed read ibSmaPortLinkSpeedSupported 132 Sun Datacenter InfiniBand Switch 36 Command Reference April 2011 Description of Task or Activity Action MIB OID Display the SMA link state of the port read ibSmaPortLinkState Display the SMA physical state of the port read ibSmaPortPhysState Display the SMA LinkDownDefault state read ibSmaPortLinkDownDefaultState Display the SMA LID mask control count for read ibSmaPortLidMaskCo
107. mes Alias for name Format ClassPortInfo CPI NodeRecord NR PortInfoRecord PIR SL2VLTableRecord SL2VL Jid in_port out_port PKeyTableRecord PKTR Jid port block VLArbitrationTableRecord VLAR Jid port block InformInfoRecord IIR Understanding InfiniBand Commands Query Names Alias for name Format LinkRecord LR from_lid from_port to_lid to_port ServiceRecord SR PathRecord PR MCMemberRecord MCMR LFTRecord LFTR lid block MFTRecord MFTR mlid position block Description This InfiniBand command performs the selected Subnet Administrator query Node records are queried by default The saquery command is available from the SYS Fabric_Mgmt Linux shell target of the Oracle ILOM CLI interface Options The following table describes the options to the saquery command and their purposes Option Purpose h Provides help d Sets the debug level Can be used several times to increase the debug level p Displays the PathRecord information N Displays the NodeRecord information D Displays the NodeDescriptions of channel adapters only S Displays ServiceRecord information I Displays InformInfoRecord information L Returns the LIDs of the specified name 1 Returns the unique LID of the specified name G Returns the GUIDs of the specified name 0 Returns the name of the specified LID 118 Sun Datacenter InfiniBand Switch 36 Command R
108. n ibdiagnet log Dump of all the application reports generated according to the provided flags ibdiagnet lst List of all the nodes ports and links in the fabric ibdiagnet fdbs Dump of the unicast forwarding tables of the fabric switches ibdiagnet mcfdbs Dump of the multicast forwarding tables of the fabric switches ibdiagnet masks In case of duplicate port node GUIDs this file includes the map between masked GUIDs and real GUIDs ibdiagnet sm List of all the Subnet Manager state and priority in the fabric ibdiagnet pm Dump of the Performance Manager counters values for the fabric links ibdiagnet pkey Dump of the existing partitions and their member host ports ibdiagnet mcg Dump of the multicast groups their properties and member host ports ibdiagnet db Dump of the internal subnet database You can load this file in later runs using the load_db option During the discovery phase the command also checks for duplicate node port GUIDs in the InfiniBand fabric If such an error is detected it is displayed on the standard output Understanding InfiniBand Commands 83 After the discovery phase is completed directed route packets are sent multiple times to detect possible problematic paths on which packets might be lost A report of suspected bad links is displayed on the standard output If requested with the r option a full report of fabric qualities is displayed including m Subnet Manager report Number of
109. n and adaptation shall be subject to the restrictions and license terms set forth in the applicable Government contract and to the extent applicable by the terms of the Government contract the additional rights set forth in FAR 52 227 19 Commercial Computer Software License December 2007 Oracle America Inc 500 Oracle Parkway Redwood City CA 94065 This software or hardware is developed for general use in a variety of information management applications It is not developed or intended for use in any inherently dangerous applications including applications which may create a risk of personal injury If you use this software or hardware in dangerous applications then you shall be responsible to take all appropriate fail safe backup redundancy and other measures to ensure its safe use Oracle orporation and its affiliates disclaim any liability for any damages caused by use of this software or hardware in dangerous applications Oracle and Java are registered trademarks of Oracle and or its affiliates Other names may be trademarks of their respective owners AMD Opteron the AMD logo and the AMD Opteron logo are trademarks or registered trademarks of Advanced Micro Devices Intel and Intel Xeon are trademarks or registered trademarks of Intel Corporation All SPARC trademarks are used under license and are trademarks or registered trademarks of SPARC International Inc UNIX is a registered trademark licensed through X Open Company Ltd
110. n page m ibtracert Command on page 112 m Linux Shells for InfiniBand Commands on page 59 Understanding InfiniBand Commands 103 ibrouters Command Displays InfiniBand router nodes in topology Syntax ibrouters h topology C ca_namel P ca_port t timeout where m topology is the topology file m ca_name is the channel adapter name m ca_port is the channel adapter port m timeout is the timeout in milliseconds Description This InfiniBand software command is a script that discovers the InfiniBand fabric topology or uses an existing topology file to extract the router nodes The ibrouters command is available from the SYS Switch_Diag and SYS Fabric_Mgmt Linux shell targets of the Oracle ILOM CLI interface Options The following table describes the options to the ibrouters command and their purposes Option Purpose h Provides help Uses the specified channel adapter name P Uses the specified channel adapter port E Overrides the default timeout 104 Sun Datacenter InfiniBand Switch 36 Command Reference April 2011 Example The following example shows how to display router nodes with the ibrouters command Note The output in the example is a portion of the full output and varies for each InfiniBand topology ibrouters Router 0x00066a00d80003fd ports 24 Hellios 4024 Router enhanced port 0 lid 7 lmc 0 Related Information m ibrouters man page m
111. n page 163 High Level OIDs The following table lists the high level object identifier supported by the SUN PLATFORM MIB MIB Description of Task or Activity Action MIB OID Display the time at which the agent was last started Related Information read sunPlatStartTime a OID Tables Overview on page 127 m SUN PLATFORM MIB MIB OID Command Syntax on page 153 NIM Equipment Table OIDs The following table lists NIM equipment object identifiers supported by the SUN PLATFORM MIB MIB Description of Task or Activity Action MIB OID Display the NIM equipment table read Display information about a particular piece of read equipment within the network element of the type specified by entPhysicalClass sunPlatEquipmentTable sunPlatEquipmentEntry Display or set the administrative state of the read managed object write Display the operational state of the managed read object sunPlatEquipmentAdministrativeState sunPlatEquipmentOperationalState Understanding SNMP MIB OIDs 155 Description of Task or Activity Action MIB OID Display the alarm status of the managed object read Display the unknown or known status of the read managed object sunPlatEquipmentAlarmStatus sunPlatEquipmentUnknownStatus Display or set the specific or general location read name of the component write sunPlatEquipmentLocationName Related Information m OID Tab
112. nd Reference April 2011 Example The following example shows how to disable logging of link events to the Syslog with the disablecablelog command disablelinklog Stopping Environment daemon OK Starting Environment daemon OK Related Information m enablelinklog Command on page 20 m disablecablelog Command on page 15 m Linux Shells for Hardware Commands on page 3 disablesm Command Disables the Subnet Manager within the management controller Syntax disablesm Description This hardware command disables the OpenSM opensmd daemon You use this command in the event that a Subnet Manager external to the switch is preferred The disablesm command is available from the SYS Fabric_Mgmt Linux shell target of the Oracle ILOM CLI interface Understanding Hardware Commands 17 Example The following example shows how to disable the opensmd daemon with the disablesm command disablesm Stopping partitiond daemon OK Stopping IB Subnet Manager OK Related Information m enablesm Command on page 21 m setsmpriority Command on page 42 m Linux Shells for Hardware Commands on page 3 disableswitchport Command Disables a connector or switch chip port Syntax disableswitchport reason reason connector Switch port where m reason is the reason for disabling the port Blacklist or Partition connector is the number
113. ndividually is equivalent to the system boot sequence Understanding Hardware Commands 39 The setcontrolledhandover command is available from the SYS Fabric_Mgmt Linux shell target of the Oracle ILOM CLI interface Example The following example shows how to enable a controlled handover of Subnet Managers with the setcontrolledhandover command setcontrolledhandover TRUE etc opensm opensm conf updated setcontrolledhandover INFO Current setting in etc opensm opensm conf controlled_handover TRUE setcontrolledhandover INFO Current setting in etc opensm opensm conf sm_priority 0 Related Information m enablesm Command on page 21 m setsmpriority Command on page 42 m setsubnetprefix Command on page 44 m Linux Shells for Hardware Commands on page 3 setloghost Command Sets the remote log host Syntax setloghost IP_address hostname localhost where a IP_address is the IP address of the remote server hosting the Syslog m hostname is the host name of the remote server hosting the Syslog 40 Sun Datacenter InfiniBand Switch 36 Command Reference April 2011 Description This hardware command sets the remote location to where the Syslog output is directed The localhost option disables the redirection Example The following example shows how to redirect the output of Syslog to the server SyslogHost using the setloghost command Note You must restart the Subne
114. netdiscover Command on page 92 ibchecknode Command Validates InfiniBand nodes and reports errors Syntax ibchecknode v h N G C ca_name P ca_port t timeout lid dr_path guid where m ca_name is the channel adapter name m ca_port is the channel adapter port m timeout is the timeout in milliseconds m lid is the local identifier m guid is the global unique identifier Description This InfiniBand command checks node connectivity and performs a simple check to verify the functionality of the specified node Note The port address is a LID unless the G option is used to specify a GUID address 66 Sun Datacenter InfiniBand Switch 36 Command Reference April 2011 Options The following table describes the options to the ibchecknode command and their purposes Option Purpose h Provides help N Uses mono mode instead of color mode G Uses the port GUID address C Uses the specified channel adapter name P Uses the specified channel adapter port t Overrides the default timeout Example The following example shows how to check if LID 15 is active with the ibchecknode command ibchecknode v 15 Node check lid 15 OK Related Information m ibchecknode man page m ibaddr Command on page 60 a smpquery Command on page 124 ibcheckport Command Validates InfiniBand ports and reports errors Understanding InfiniBand Commands 67 Syntax
115. nfiniBand Switch 36 Command Reference April 2011 Example The following example shows how to display the mapping for connector 5A with the dcsport command dcsport connector 5A Connector 5A maps to Switch port 30 Related Information m enablesm Command on page 21 m setsmpriority Command on page 42 m Linux Shells for Hardware Commands on page 3 disablecablelog Command Disables logging of cable events Syntax disablecablelog Description This hardware command disables logging of cable events to the Syslog The disablecablelog command is available from the SYS Fabric_Mgmt Linux shell target of the Oracle ILOM CLI interface Understanding Hardware Commands 15 Example The following example shows how to disable logging of cable events to the Syslog with the disablecablelog command disablecablelog Stopping Environment daemon OK Starting Environment daemon OK Related Information m enablecablelog Command on page 20 m disablelinklog Command on page 16 m Linux Shells for Hardware Commands on page 3 disablelinklog Command Disables logging of link events Syntax disablelinklog Description This hardware command disables logging of link events to the Syslog The disablelinklog command is available from the SYS Fabric_Mgmt Linux shell target of the Oracle ILOM CLI interface 16 Sun Datacenter InfiniBand Switch 36 Comma
116. nfiniBand Switch 36 Command Reference April 2011 PMA Port Counters Table OIDs The following table lists PMA port counter object identifiers supported by the SUN DCS MIB MIB Description of Task or Activity Action MIB OID Display a table of PMA Port Counters information read ibPmaPortCntrsTable Display a row of the ibPmaPortCntrsTable read ibPmaPortCntrsEntry Display an index of PMA nodes read ibPmaPortCntrsNode Display an index of the PMA InfiniBand data ports read ibPmaPortCntrsPort Display the total number of symbol errors detected on one or more physical lanes read ibPmaSymbolErrCounter Display the number of times the port training state machine has successfully completed the link error recovery process read ibPmaLin kErrRecoveryCntr Display the number of times the port training state machine has failed the link error recovery process and downed the link read ibPmaLin kDownedCntr Display the number of packets containing an error that were received on the port read ibPmaPor tCRcevErr Display the number of packets marked with the End of Bad Packets EBP delimiter received on the port read ibPmaPor tRcovRemPhysErr Display the number of packets received on the port that could not be forwarded by the switch relay read ibPmaPor tRevSwitchRelayErr Display the number of outbound packets d
117. nodes cleared 0 errors Related Information m ibclearcounters man page m ibnetdiscover Command on page 92 m perfquery Command on page 114 ibclearerrors Command Clears error counters in the InfiniBand fabric Syntax ibclearerrors h N topology C ca_name P ca_port t timeout where Understanding InfiniBand Commands 77 m topology is the topology file m ca_name is the channel adapter name m ca_port is the channel adapter port m timeout is the timeout in milliseconds Description This InfiniBand command is a script that clears the Performance Manager agent error counters in PortCounters by either discovering the InfiniBand fabric topology or using an existing topology file Options The following table describes the options to the ibclearerrors command and their purposes Option Purpose h Provides help N Uses mono mode instead of color mode c Uses the specified channel adapter name P Uses the specified channel adapter port t Overrides the default timeout Example The following example shows how to clear all error counters with the ibclearerrors command ibclearerrors Summary 5 nodes cleared 0 errors Related Information m ibclearerrors man page m ibnetdiscover Command on page 92 78 Sun Datacenter InfiniBand Switch 36 Command Reference April 2011 m perfquery Command on page 114 ibdatacounters Command Queries the Infini
118. nts Command Displays InfiniBand fabric port data counters Syntax ibdatacounts b G h N v C ca_name P ca_port t timeout lid guid port where 80 Sun Datacenter InfiniBand Switch 36 Command Reference April 2011 m ca_name is the channel adapter name m ca_port is the channel adapter port m timeout is the timeout in milliseconds m lid is the local identifier m guid is the global unique identifier m port is the port being validated Description This InfiniBand command returns the Performance Manager agent data counters from a specified port or node Note The port address is a LID unless the G option is used to specify a GUID address Options The following table describes the options to the ibdatacounts command and their purposes Option Purpose b Enables brief mode Reduced output is only if errors are present Does not identify the errors G Uses the port GUID address h Provides help N Uses mono mode instead of color mode v Provides verbose output C Uses the specified channel adapter name P Uses the specified channel adapter port t Overrides the default timeout Understanding InfiniBand Commands 81 Example The following example shows how to display the data counters for LID 15 port 23 with the ibdatacounts command ibdatacounts 15 23 Port counters Lid 15 port 23 MMCEDAC a toc ce ere Sea sha Sees es Sw aE 6048 RGVDACAs cia
119. o tifica tionPerceivedSeverity Display or set an optional probable cause which provides additional information relevant to the notification read sunPla No tifica tionProbableCause Display or set an optional description which provides additional information concerning the cause of the notification read sunPlatNotificationSpecificProblem Display or set a list of recommended repair actions Display an optional object identifier which provides additional information relevant to the notification read read sunPla sunPla No tifica tifica tionRepairAction tionAdditionaliInfo Display or set an optional description which provides additional information relevant to the notification read sunPla tifica tionAdditionalText Display the changed object s OBJECT IDENTIFIER value in an attribute or state change notification read sunPla identi 1er tifica tionChangedobject Display the new INTEGER value in an attribute or state change notification read sunPla tifica tionNewInteger Display the old INTEGER value in an attribute or state change notification read sunPla No tifica tionOldInteger Display the new OCTET STRING value in an attribute change notification read sunPla tifica tionNewString 162 Sun Datacenter InfiniBand Switch 36 Command Reference A
120. ode Command kport Command kportstate Command on page 69 ibchec kportwidth Command on page 71 ibchec on page 72 ibchec kstate Command kwidth Command on page 74 57 Command Syntax Links ibclearcounters ibclearerrors h topology C ca_name P ca_port t timeout h N topology C ca_name P ca_port t timeout ibdatacounters b h N v topology C ca_name P ca_port t timeout ibdatacounts timeout lid guid port ibdiagnet ibdiagpath n src_name dst_name 1 src_lid dst_lid d p1 p2 p3 c b G h N v C ca_name P ca_port t c count v r o outputdir t topology s system i device p port wt topology pm pc P PM value lw 1x 4x 12x ls 2 5 5 101 skip checks load_db file h V count v o outputdir t topology s system i device p port wt topology pm pc P PM value 1w 1x 4x 12x ls 2 5 5 10 skip checks load_db file h v ibhosts h topology C ca_name P ca_port t timeout ibnetdiscover d el v s 1 9 H S R C ca_namel P ca_port t timeout V p h topology topology C ca_name P ca_port t timeout s smlid v C ca_name P ibnetstatus h ibnodes h ibportstate d D e G h ca_port t timeout lid dr_path g
121. odeDescription lid LID widthspeed For example vendid 0x2c9 devid 0xbd36 sysimgguid 0x21283a8389a0a3 switchguid 0x21283a8389a0a0 21283a8389a0a0 Switch 36 S 0021283a8389a0a0 Sun DCS 36 QDR switch localhost enhanced port 0 lid 15 lmc 0 23 H 0003ba000100e388 2 3ba000100e38a nsn33 43 HCA 1 lid 14 4xQDR Options The following table describes the options to the ibnetdiscover command and their purposes Option Purpose d Sets the debug level Can be used several times to increase the debug level e Displays send and receive errors v Provides verbose output Understanding InfiniBand Commands 93 Option Purpose s Shows more information 1 Lists the connected nodes g Shows the grouping and switch external ports correspondence H Lists the connected channel adapters S Lists the connected switches R Lists the connected routers C Uses the specified channel adapter name P Uses the specified channel adapter port e Overrides the default timeout V Displays the version information node name map Reads the node name map file p Returns a list of connected ports including status information e LID portnum e GUID e link width e link speed e NodeDescription h Provides help Example The following example shows how to discover the InfiniBand fabric topology with the ibnetdiscover command Note The output for your InfiniBand fabric
122. olumns are Description of Task or Activity The text under this heading describes what you want to do or information you want to see m Action The verbs under this heading describe the action respective to the SNMP client software interface For example a verb of read means to use the snmpget snmpwalk or snmptable command in the NetSNMP CLI client MIB OID The string under this heading is the object identifier of the respective MIB that is used to accomplish the task or activity Note The OID provided in the right column might not be complete You might need to appended the OID with a 0 if the OID is a scalar OID or a x where x is 1 to a maximum value if the OID is a tabular OID 127 A table OID has a Table suffix and the OIDs listed beneath it are most likely to be columns of that table An index OID has an Index suffix and while the OID is not directly accessible the OID is still used to return a specific row of a table OID Related Information a Understanding the SUN DCS MIB MIB OIDs on page 128 m SUN HW TRAP MIB MIB OIDs on page 141 m Understanding the SUN ILOM CONTROL MIB MIB OIDs on page 142 m Understanding the SUN PLATFORM MIB MIB OIDs on page 153 a Understanding the ENTITY MIB MIB OIDs on page 163 128 Understanding the SUN DCS MIB MIB OIDs This topic provides tables of the hardware Subnet Manager Performance Manager and SNMP trap object iden
123. ommand Hardware Terminates the session Syntax exit Description This hardware command immediately terminates the session with the management controller Example The following example shows how to terminate the session with the exit command exit Connection to 123 45 67 89 closed Related Information m Switch Remote Administration exit command 26 Sun Datacenter InfiniBand Switch 36 Command Reference April 2011 generatetopology Command Creates topology file Syntax generatetopology topofile h where topofile is the filename and path to the topology file Description This hardware command creates a topology file of the InfiniBand fabric This file is not compatible with the topology file created by the ibnetdiscover command The generatetopology command is used with the matchtopology and showtopology commands to determine changes in the InfiniBand fabric The h option provides help The generatetopology command is available from the SYS Fabric_Mgmt Linux shell target of the Oracle ILOM CLI interface Example The following example shows how to create a topology file called Topo conf with the generatetopology command generatetopology Sept8 topo It will take some time to generate a topology file Please wait topo conf exist will move it to topo conf old will create new topo conf Topo conf file is created Will now start generating the topo file Wrote Topology file
124. operation Description This InfiniBand command permits a subset of the standard SMP queries including the following m Node information m Node description m Switch information m Port information Output is in human readable format Supported operations and parameters are as follows m nodeinfo addr m nodedesc addr 124 Sun Datacenter InfiniBand Switch 36 Command Reference April 2011 portinfo addr portnum switchinfo addr pkeys addr portnum s12v1 addr portnum vlarb addr portnum guids addr where addr is the address m portnum is the port number The smpquery command is available from the SYS Switch_Diag and SYS Fabric_Mgmt Linux shell targets of the Oracle ILOM CLI interface Options The following table describes the options to the smpquery command and their purposes Option Purpose d Sets the debug level Can be used several times to increase the debug level D Uses the directed path address The path is a comma delimited sequence of out ports e Displays send and receive errors G Uses the port GUID address h Provides help v Provides verbose output V Displays the version information C Uses the specified channel adapter name P Uses the specified channel adapter port St Overrides the default timeout Understanding InfiniBand Commands 125 126 Example The following example shows how to display node information for LID 15 with the smpquery com
125. optional inbound raw packet read ibSmaPortFilterRawPkt Inbound enforcement Display support of optional outbound raw read ibSmaPortFilterRawPktOutbound packet enforcement Understanding SNMP MIB OIDs 133 Description of Task or Activity Action MIB OID Display the local physical error threshold value read When the threshold is exceeded a local link integrity error is determined ibSmaPortLocalPhysErrorThreshold Display overrun error threshold value When the read number of buffer overruns exceeds the threshold an excessive buffer overrun error is determined ibSmaPortOverrunErrorThreshold Display a mapping of an InfiniBand device SMA read port to connector Related Information ibSmaPortConnectorPosition a OID Tables Overview on page 127 SUN DCS MIB MIB OID Command Syntax on page 129 Understanding Performance Manager Agent OIDs Performance Manager object identifiers are provided in these tables m PMA Port Counters Table OIDs on page 135 m PMA Extended Port Counters Table OIDs on page 136 Related Information Understanding SNMP Trap OIDs on page 137 OID Tables Overview on page SUN HW TRAP MIB MIB OIDs 127 on page 141 Understanding the SUN ILOM CONTROL MIB MIB OIDs on page 142 Understanding the SUN PLATFORM MIB MIB OIDs on page 153 Understanding the ENTITY MI1 B MIB OIDs on page 163 134 Sun Datacenter I
126. or set the lower threshold read sunPlatNumericSensorLowerThresholdCritical at which a critical condition write occurs Display or set the upper threshold read sunPlatNumericSensorUpperThresholdCritical at which a critical condition write occurs Display or set the lower threshold read sunPlatNumericSensorLowerThresholdFatal at which a fatal condition occurs write Display or set the upper threshold read sunPlatNumericSensorUpperThresholdFatal at which a fatal condition occurs write Display the hysteresis around the read sunPlatNumericSensorHysteresis thresholds Display or enable the thresholds read sunPlatNumericSensorEnabledThresholds of the sensor write Set the sensors thresholds to the read sunPlatNumericSensorRestoreDefaultThresholds default values write Related Information a OID Tables Overview on page 127 m SUN PLATFORM MIB MIB OID Command Syntax on page 153 Understanding SNMP MIB OIDs 159 Discrete Sensor Table OIDs The following table lists discrete sensor object identifiers supported by the SUN PLATFORM MIB MIB Description of Task or Activity Action MIB OID Display the discrete sensor table read sunPlatDiscreteSensorTable Display information about a discrete sensor read sunPlatDiscreteSensorEntry with entPhysicalClass of sensor 8 and discrete 3 Display the current reading of the sensor read sunPlatDiscreteSensorCurrent Related Information m OID Tables Overview on page
127. orType Display or set the update interval for the sensor read measured in milliseconds sunPlatSensorLatency Related Information m OID Tables Overview on page 127 m SUN PLATFORM MIB MIB OID Command Syntax on page 153 Sun Platform Binary Sensor Table OIDs The following table lists binary sensor object identifiers supported by the SUN PLATFORM MIB MIB Description of Task or Activity Action MIB OID Display a table of attributes specific to binary read sensors sunPlatBinarySensorTable Display information about a sensor with a read sunPlatSensorClass value of binary 1 sunPlatBinarySensorEntry Display the current state of the sensor read sunPlatBinarySensorCurrent Understanding SNMP MIB OIDs 157 Description of Task or Activity Action MIB OID Display the expected state of the sensor read sunPlatBinarySensorExpected Display or set the interpretation to be applied to read sunPlatBinarySensorInterpretTrue a sensor reading of true Display or set the interpretation to be applied to read sunPlatBinarySensorInterpretFalse a sensor reading of false Related Information m OID Tables Overview on page 127 m SUN PLATFORM MIB MIB OID Command Syntax on page 153 Sun Platform Numeric Sensor Table OIDs The following table lists numeric sensor object identifiers supported by the SUN PLATFORM MIB MIB Description of Task or Activity Action MIB OID Display
128. ote State changes made with the ibportstate command are not recognized by the disableswitchport enableswitchport or listlinkup commands The listlinkup command is available from the SYS Switch_Diag and SYS Fabric_Mgmt Linux shell targets of the Oracle ILOM CLI interface Example The following example shows how to display link presence and associated ports with the listlinkup command listlinkup Connector OA Present lt gt Switch Port 20 up Enabled Connector 1A Not present Connector 2A Not present Connector 3A Not present Connector 4A Not present Connector 0B Not present Connector 1B Not present Understanding Hardware Commands 35 Connector 17B Not present Related Information m ibportstate Command on page 99 m Linux Shells for Hardware Commands on page 3 managementreset Command Resets the management controller Syntax managementreset r Description This hardware command resets the management controller the CPLD and the 14 switch chip The command requests a reboot and in most situations this should be done The managementreset command also forces links to retrain upon management controller services startup The r option bypasses the query for reboot and reboots automatically Example The following example shows how to reset the management controller and InfiniBand fabric services with the managementreset command 36 Sun Datacenter InfiniBand Switch 36
129. pril 2011 Description of Task or Activity Action MIB OID Display the old OCTET STRING value read sunPlatNotificationO0ldString in an attribute change notification Display the new OBJECT read sunPlatNotificationNewobject identifier IDENTIFIER value in an attribute change notification Display the old OBJECT IDENTIFIER read sunPlatNotificationOldobject identifier value in an attribute change notification Display or set a comma delimited list read sunPlatNotificationCorrelatedNotifications of sunPlatNotificationEventIDs which are correlated to the notification Related Information a OID Tables Overview on page 127 m SUN PLATFORM MIB MIB OID Command Syntax on page 153 Understanding the ENTITY MIB MIB OIDs This topic provides tables of physical and logical entity object identifiers Topics include a ENTITY MIB MIB OID Command Syntax on page 164 m Physical Entity Table OIDs on page 165 Related Information m OID Tables Overview on page 127 m Understanding the SUN m SUN HW TRAP MIB MIB OIDs on page 141 m Understanding the SUN ILOM CONTROL MIB MIB OIDs on page 142 DCS MIB MIB OIDs on page 128 m Understanding the SUN PLATFORM MIB MIB OIDs on page 153 Understanding SNMP MIB OIDs 163 ENTITY MIB MIB OID Command Syntax When you use the object identifiers in a command syntax you must include the ENTITY MIB MIB name
130. re specified by their LIDs In LID route addressing the actual path from the local port to the source port and from the source port to the destination port is defined by means of Subnet Management Linear Forwarding Table queries of the switch nodes along those paths Note When the ibdiagpath command queries the performance counters along the path between the source and destination ports the command always traverses the LID route regardless of whether a directed route is specified If one or more links along the LID route are not in the Active state the ibdiagpath command reports an error This command produces a set of files in the output directory By default the output directory is tmp The following table describes the files File Name Description ibdiagpath log ibdiagpath pm Dump of all the application reports generated according to the provided flags Dump of the Performance Manager counters values for the fabric links Options The following table describes the options to the ibdiagpath command and their purposes Option Purpose Identifies the source and destination ports Identifies the source and destination LIDs Sets directed route from the local node to the destination node Sets the minimum number of packets sent across each link Provides verbose output Specifies the topology file name Specifies the local system name In the case of multiple devices on the
131. ril 2011 ibdiagpath Command Traces the InfiniBand fabric diagnostic path Syntax ibdiagpath n src_name dst_name 1 src_lid dst_lid a p1 p2 p3 c count v o outputdir t topology s system i device p port wt topology pm pc P PM value 1w 1x 4x 12x ls 22515 101 h V where m src_name is the source port m dst_name is the destination port m src_lid is the source LID m dst_lid is the destination LID p1 p2 p3 is the directed route m count is the number of packets m outputdir is the output directory m topology is the topology file m system is the local system name m device is the index of the device connecting to the InfiniBand fabric m port is the port of the device m PM is the Performance Manager counter number m value is the threshold of the Performance Manager counter Description This InfiniBand command traces a path between two endpoints and provides information regarding the nodes and ports traversed along the path The command uses device specific health queries for the different devices encountered The way the ibdiagpath command operates is determined from the addressing mode specified on the command line m If directed route addressing is used the local node is the source node and the route to the destination port is known Understanding InfiniBand Commands 87 m If LID route addressing is used the source and destination ports of a route a
132. ring e 2 Standby e 3 Master p Sets the priority 0 15 a Sets the activity count G Uses the port GUID address h Provides help V Displays the version information C Uses the specified channel adapter name P Uses the specified channel adapter port t Overrides the default timeout Understanding InfiniBand Commands 121 Example The following example shows how to display the SMInfo with the sminfo command sminfo sminfo sm lid 15 sm guid 0x21283a8389a0a0 activity count 32046 priority 8 state 3 SMINFO_MASTER Related Information sminfo man page getmaster Command on page 29 smpdump Command on page 122 smpdump Command Dumps the InfiniBand fabric management attributes Syntax smpdump s D h V C ca_name P ca_port t timeout lid dr_path attr mod where ca_name is the channel adapter name ca_port is the channel adapter port timeout is the timeout in milliseconds lid is the local identifier dr_path is the directed path attr is the InfiniBand architecture attribute ID for Subnet Manager attribute mod is the InfiniBand architecture modifier for Subnet Manager attribute 122 Sun Datacenter InfiniBand Switch 36 Command Reference April 2011 Description This InfiniBand command is a general purpose SMP utility that returns Subnet Manager attributes from a specified SMA The output is in hexadecimal Options The followin
133. rlAlertDestinationEmail notifications when the alert type is email 1 write Display or set the version of SNMP trap thatis read ilomCtrlAlertSNMPVersion used for the given alert rule write Display or set the community string to be used read ilomCtrlAlertSNMPCommunityOrUsername when the ilomCtrlAlertSNMPVersion write property is set to v1 or v2c Display or set the destination port for SNMP read ilomCtrlAlertDestinationPort traps write Display or set the class name to filter emailed read ilomCtrlAlertEmailEventClassFilter alerts on write Display or set the type name to filter emailed read ilomCtrlAlertEmailEventTypeFilter alerts on write Display or set an optional format to identify the read ilomCtrlAlertEmailCustomSender sender or the from address write Display or set an optional string added to the read ilomCtrlAlertEmailMessagePrefix beginning of the message body write Related Information a OID Tables Overview on page 127 m SUN ILOM CONTROL MIB MIB OID Command Syntax on page 143 150 Sun Datacenter InfiniBand Switch 36 Command Reference April 2011 Clock OIDs The following table lists clock object identifiers supported by the SUN ILOM CONTROL MIB MIB Description of Task or Activity Action MIB OID Display or set the date and time of the device read ilomCtr1DateAndTime write Display or set whether or not Network Time read ilomCtr1NTPEnabled Protocol is enabled write Display or
134. rovides help N Uses mono mode instead of color mode c Uses the specified channel adapter name P Uses the specified channel adapter port t Overrides the default timeout Example The following example shows how to check error counters for all LIDs in the InfiniBand fabric with the ibchecknet command Note The output in the example is a portion of the full output ibchecknet warn counter SymbolErrors 3121 threshold 10 lid 25 port 255 warn counter RcvSwRelayErrors 48545 threshold 100 lid 25 port 255 warn counter XmtDiscards 9789 threshold 100 lid 25 port 255 Error check on lid 25 Sun DCS 72 QDR FC switch o4nm2 72p 2 port all FAILED warn coun RevSwRelayErrors 56839 threshold 100 lid 25 port 28 Error check lid 25 Sun DCS 72 QDR FC switch o4nm2 72p 2 port 28 FAILED warn coun RevSwRelayErrors 56839 threshold 100 lid 25 port 9 Error check on lid 25 Sun DCS 72 QDR FC switch o4nm2 72p 2 port 9 FAILED warn counter XmtDiscards 9714 threshold 100 lid 25 port 1 Error check on lid 25 Sun DCS 72 QDR FC switch o4nm2 72p 2 port 1 FAILED Summary 6 nodes checked 0 bad nodes found 142 ports checked 0 bad ports found 3 ports have errors beyond threshold Understanding InfiniBand Commands 65 Related Information m ibchecknet man page m ibcheckerrors Command on page 62 m ibchecknode Command on page 66 m ibcheckport Command on page 67 m ib
135. s the local identifier dr_path is the directed path guid is the global unique identifier Description This InfiniBand software command displays the LID and range as well as the GID address of the port specified The local port information is provided by default Note This command is also used as a simple address resolver Options The following table describes the options to the ibaddr command and their purposes Option Purpose d Sets the debug level Can be used several times to increase the debug level D Uses the directed path address The path is a comma delimited sequence of out ports G Shows the LID range and GID for port GUID addresses 1 Shows the LID range only g Shows the GID address only C Uses the specified channel adapter name P Uses the specified channel adapter port t Overrides the default timeout Understanding InfiniBand Commands 61 Option Purpose V Displays the version information h Provides help Example The following example shows how to display the local port s GID and LID range with the ibaddr command ibaddr GID fe80 21 283a 8389 a0a0 LID start Oxf end Oxf Related Information m ibaddr man page m ibroute Command on page 101 m ibtracert Command on page 112 ibcheckerrors Command Validates InfiniBand fabric and report errors Syntax ibcheckerrors h b v N topology C ca_name P ca_port t timeo
136. set the configured time zone string read ilomCtrlTimezone write Related Information a OID Tables Overview on page 127 m SUN ILOM CONTROL MIB MIB OID Command Syntax on page 143 Backup and Restore OIDs The following table lists backup and restore object identifiers supported by the SUN ILOM CONTROL MIB MIB Description of Task or Activity Action MIB OID Set the target destination of a configuration write XML file during backup and restore The syntax is protocol user passwword host 1 path file ilomCtrlBackupAndRestoreTargetURI Set the passphrase for encrypting or decrypting write sensitive data during backup and restore Set the action to backup or restore write ilomCtrlBackupAndRestorePassphrase ilomCtrlBackupAndRestoreAction Display the current status of backup or restore read ilomCtrl1BackupAndRestoreActionStatus Related Information m OID Tables Overview on page 127 m SUN ILOM CONTROL MIB MIB OID Command Syntax on page 143 Understanding SNMP MIB OIDs 151 Identification OIDs The following table lists identification object identifiers supported by the SUN ILOM CONTROL MIB MIB Description of Task or Activity Action MIB OID Display or set the host name of the server read ilomCtr1lSystemIdentifier associated with Oracle ILOM to be sent out inthe write varbind for all traps that Oracle LOM generates
137. splay or set the role that is associated witha read ilomCtrlLocalUserRoles user write Create a new user or delete an existing user write ilomCtrlLocalUserRowStatus Display or set the CLI mode a user is configured read ilomCtrlLocalUserCLIMode write Related Information m OID Tables Overview on page 127 m SUN ILOM CONTROL MIB MIB OID Command Syntax on page 143 Session OIDs The following table lists session object identifiers supported by the SUN ILOM CONTROL MIB MIB Description of Task or Activity Action Display a table of information about the current read user sessions MIB OID ilomctrlSessionsTable 148 Sun Datacenter InfiniBand Switch 36 Command Reference April 2011 Description of Task or Activity Action MIB OID Display the user name of the user associated with read the session ilomCtrl1SessionsUsername Display the type of connection that the given user read is using to access the device ilomCtrl1SessionsConnectionType Display the date and time that the user logged read into the device ilomCtrl1SessionsLoginTime Related Information a OID Tables Overview on page 127 m SUN ILOM CONTROL MIB MIB OID Command Syntax on page 143 Event Log OIDs The following table lists event log object identifiers supported by the SUN ILOM CONTROL MIB MIB Description of Task or Activity Action MIB OID Display a tab
138. t Manager using the disablesm and enablesm commands after setting the loghost setloghost SyslogHost Shutting down kernel logger OK Shutting down system logger OK Starting system logger OK Starting kernel logger OK Related Information m disablesm Command on page 17 m enablesm Command on page 21 setmsmlocationmonitor Command Sets monitoring of the Subnet Manager Syntax setmsmlocationmonitor state list h where state is either enable or disable Understanding Hardware Commands 41 Description This hardware command sets the state of monitoring the location and condition of the primary or Master Subnet Manager for the InfiniBand fabric You can set the state of monitoring to either enabled or disabled The list option displays the current state of monitoring Example The following example shows how to display the state of the Subnet Manager monitor with the setmsmlocationmonitor command setmsmlocationmonitor list Current state of Master Subnet Manager monitioring enable Related Information m disablesm Command on page 17 m enablesm Command on page 21 setsmpriority Command Sets the Subnet Manager priority Syntax setsmpriority priority list where priority is a number from 0 lowest to 13 highest Description This hardware command sets the priority of the Subnet Manager within the management controller You use
139. table describes the options to the ibsysstat command and their purposes Option Purpose d Sets the debug level Can be used several times to increase the debug level e Displays send and receive errors G Uses the port GUID address h Provides help s Uses smlid as the target LID for Subnet Manager Subnet Administrator queries v Provides verbose output V Displays the version information C Uses the specified channel adapter name P Uses the specified channel adapter port it Overrides the default timeout 0 Uses specified OUI number to multiplex vendor management datagrams Understanding InfiniBand Commands 111 Option Purpose S Starts in server mode Example The following example shows how to retrieve system information about a remote node server from a local node client with the ibsysstat command First configure the remote node server ibsysstat S lt CTRL C to exit server gt Then run the command on the local node client ibsysstat 15 ping sysstat ping succeeded ibsysstat 15 host nsn105 100 nsn sfbay sun com ibsysstat 15 cpu cpu cpu cpu cpu 0 model 1 model 2 model 3 model AMD Opteron tm AMD Opteron tm AMD Opteron tm AMD Opteron tm Related Information Processor Processor Processor Processor m ibsysstat man page 112 848 MHZ 848 MHZ 848 MHZ 848 MHZ 2189 2189 2189 2189 ibtracert Command Traces the In
140. this command when there are multiple Subnet Managers in the InfiniBand fabric By setting a Subnet Manager to a higher priority 42 Sun Datacenter InfiniBand Switch 36 Command Reference April 2011 than another Subnet Manager it becomes the primary or Master Subnet Manager When you set a Subnet Manager to a priority lower than another Subnet Manager it becomes the secondary Subnet Manager The list option provides a listing of the Subnet Manager settings in respect to priority controlled handover and subnet prefix The setsmpriority command writes the value of priority to the sm_priority parameter of the etc opensm opensm conf file Note You must stop or disable the OpenSM Subnet Manager before using the setsmpriority command See disablesm Command on page 17 Note Setting Subnet Managers of the same fabric to the same priority can have undesirable results The setsmpriority command is available from the SYS Fabric_Mgmt Linux shell target of the Oracle ILOM CLI interface Example The following example shows how to set the priority of the Subnet Manager to 3 using the setsmpriority command setsmpriority 3 OpenSM 3 2 6_20090717 Reading Cached Option File etc opensm opensm conf Loading Cached Option routing_engine ftree Loading Cached Option sm_priority 13 Loading Cached Option sminfo_polling_timeout 1000 Loading Cached Option polling_retry_number 3 Command Line Arguments Priorit
141. tifiers Tables of object identifiers are provided in the following topics m SUN DCS MIB MIB OID Command Syntax on page 129 m Enclosure OIDs on page 130 m Enclosure Nodes OIDs on page 130 a Neighbor Node OIDs on page 131 m Subnet Manager Info OIDs on page 132 m Subnet Manager Agent Data Port OIDs on page 132 m Understanding Performance Manager Agent OIDs on page 134 m Understanding SNMP Trap OIDs on page 137 Related Information a OID Tables Overview on page 127 m SUN HW TRAP MIB MIB OIDs on page 141 m Understanding the SUN ILOM CONTROL MIB MIB OIDs on page 142 m Understanding the SUN PLATFORM MIB MIB OIDs on page 153 Sun Datacenter InfiniBand Switch 36 Command Reference April 2011 m Understanding the ENTITY MIB MIB OIDs on page 163 SUN DCS MIB MIB OID Command Syntax When you use the object identifiers in a command syntax you must include the SUN DCS MIB MIB name For example using the V2c protocol command v2c c public mc_IP SUN DCS MIB object_id argument Or using the V3 protocol command v3 u snmp_user 1 security_level a authentication_protocol A authentication_password x DES X privacy_password mc_IP SUN DCS MIB object_id argument where command is the command of the SNMP client that performs the action m snmp_user is a configured user of the SNMP services m security_level is a noAuthNoPriv
142. tlid endlid page 112 perfquery d e G h a 1 r R v v C perfquery Command on ca_name P ca_port t timeout lid guid port reset_mask 1 page 114 saquery h d p N D S 1 L 1 G 0 U c saquery Command on s g m x C ca_namel P ca_port t timeout src to dst page 117 source destination sgid to dgid source destination name lid guid sminfo d e s state p priority a activity sminfo Command on D G h v V C ca_name P ca_port t timeout page 120 smlid smdr_path smpdump s D h V C ca_name P ca_port t timeout smpdump Command on lid dr_path attr mod page 122 smpquery d D e G h v V C ca_name P smpquery Command on ca_port t timeout lid dr_path guid op params page 124 Related Information Understanding Hardware Commands on page 1 Linux Shells for InfiniBand Commands The preferred method of accessing the Linux shell is through the SYS Switch_Diag and SYS Fabric_Mgmt Linux shell targets of the Oracle ILOM CLI interface Using the show command on the SYS Switch_Diag target opens a restricted Linux shell that enables the ilom admin user ilom operator user and users with similar permissions to run diagnostic commands Using the show command on the SYS Fabric_Mgmt target opens a different restricted Linux shell that
143. to display the status of connector 9A with the getportstatus command Note The parameters with the string Active indicate the current conditions getportstatus 9A Port status for connector 9A Switch Port 14 Adminstate Enabled LinkWidthEnabled 1X or 4X LinkWidthSupported 1X or 4X LinkWidthActive 4X LinkSpeedSupported 2 5 Gbps or 5 0 Gbps or 10 0 Gbps BinkS tates s wn ade nae Ren 4 Active PhysLinkState z c ooo ooo ooo oo LinkUp LinkSpeedActiVe z oo ooo ooo ooo 10 0 Gbps LinkSpeedEnabled 2 5 Gbps or 5 0 Gbps or 10 0 Gbps Related Information m ibcheckport Command on page 67 m ibcheckportstate Command on page 69 m ibcheckportwidth Command on page 71 help Command Hardware Displays help for a command 32 Sun Datacenter InfiniBand Switch 36 Command Reference April 2011 Syntax help command class where m command is the command for which you need help m class is the category of commands Description This hardware command provides help information for supported commands Typically the same information is provided using the h option The help command is available from the SYS Switch_Diag and SYS Fabric_Mgmt Linux shell targets of the Oracle ILOM CLI interface Example The following example shows how to get help with the help command
144. uery man page m Linux Shells for InfiniBand Commands on page 59 120 sminfo Command Queries the InfiniBand SMInfo attribute Syntax sminfo d e s state p priority a activity ca_name P ca_port t timeout smlid smdr_path where m state is the state for the Subnet Manager m priority is the priority m activity is the activity count m ca_name is the channel adapter name m ca_port is the channel adapter port ma timeout is the timeout in milliseconds m smlid is the Subnet Manager local identifier m smdr_path is the directed path for the Subnet Manager Sun Datacenter InfiniBand Switch 36 Command Reference April 2011 D G h v c Description This InfiniBand command conducts a query of the Subnet Manager and outputs the information in a human readable format The target Subnet Manager is identified in the local port information or it is specified by the smlid or smdr_path Note Using the sminfo command for other than simple queries might fault the target Subnet Manager Options The following table describes the options to the sminfo command and their purposes Option Purpose d Sets the debug level Can be used several times to increase the debug level D Uses the directed path address The path is a comma delimited sequence of out ports e Displays send and receive errors s Sets the Subnet Manager state e 0 Not active e 1 Discove
145. uid port op ibroute d a n D e G h M s smlid v v C ca_name P ca_port t timeout lid dr_path guid startlid endlid ibrouters ibstat ibstatus h topology C ca_name d e h 1 s p v V h devname ib_port P ca_port t timeout ca_name ca_port ibswitches h topology C ca_name P ca_port t timeout ibsysstat d e G h s smlid v V c ca_name P ca_port t timeout o oui S lid guid op ibclearcounters Command on page 76 ibclearerrors Command on page 77 ibdatacounters Command on page 79 ibdatacounts Command on page 80 ibdiagnet Command on page 82 ibdiagpath Command on page 87 ibhosts Command on page 90 ibnetdiscover Command on page 92 ibnetstatus Command on page 95 ibnodes Command on page 97 ibportstate Command on page 99 ibroute Command on page 101 ibrouters Command on page 104 ibstat Command on page 105 ibstatus Command on page 107 ibswitches Command on page 109 ibsysstat Command on page 110 58 Sun Datacenter InfiniBand Switch 36 Command Reference April 2011 Command Syntax Links ibtracert d D G h m mlid s smlid v V C ibtracert Command on ca_name P ca_port t timeout lid dr_path guid star
146. unt multipath support of CA and router ports Display the currently active SMA link speed read ibSmaPortLinkSpeedActive Display the enabled SMA link speed read ibSmaPortLinkSpeedEnabled Display the active maximum MTU enabled on read ibSmaPortNeighborMtu the SMA port for transmit Display the virtual lane configuration supported read ibSmaPortVirtLaneSupport on the SMA port Display the number of high priority packets that read ibSmaPortVlHighPriorityLimit are transmitted before a low priority packet is sent Display the number of virtual lane weight read ibSmaPortV1lArbHighCapacity pairs supported on the SMA port in the ibSmaHiPriVlArbTable for high priority Display the number of virtual lane weight read ibSmaPortVlArbLowCapacity pairs supported on the SMA port in the ibSmaHiPriVlArbTable for low priority Display the maximum MTU supported by the read ibSmaPortMtuCapacity SMA port Display or specify the number of sequential read ibSmaPortVlStallCount packets dropped that causes the SMA port to enter the VLStalled state Display or specify the time a packet can live at read ibSmaPortHeadOfQueueLife the head of a virtual lane queue Display the virtual lanes operational on the read ibSmaPortOperationalVls SMA port Display support of optional inbound partition read ibSmaPort PartEnforceInbound enforcement Display support of optional outbound partition read ibSmaPort PartEnforceOutbound enforcement Display support of
147. ut where topology is the topology file m ca_name is the channel adapter name ca_port is the channel adapter port m timeout is the timeout in milliseconds 62 Sun Datacenter InfiniBand Switch 36 Command Reference April 2011 Description This InfiniBand command is a script that uses the topology file created by the ibnetdiscover command to scan the InfiniBand fabric to validate the connectivity and report errors from the port counters Options The following table describes the options to the ibcheckerrors command and their purposes Option Purpose h Provides help b Enables brief mode Reduced output is only if errors are present Does not identify the errors v Provides verbose output N Uses mono mode instead of color mode C Uses the specified channel adapter name P Uses the specified channel adapter port t Overrides the default timeout Example The following example shows how to check error counters for all LIDs in the InfiniBand fabric with the ibcheckerrors command Note The output in the example is a portion of the full output ibcheckerrors warn counter SymbolErrors 3121 threshold 10 lid 25 port 255 warn counter RcvSwRelayErrors 48545 threshold 100 lid 25 port 255 warn counter XmtDiscards 9789 threshold 100 lid 25 port 255 Error check on lid 25 Sun DCS 72 QDR FC switch o4nm2 72p 2 port all FAILED warn counter RcvSwRelayErrors 56839 threshold
148. vite le cas ch ant a lui en faire part par crit Si ce logiciel ou la documentation qui l accompagne est conc d sous licence au Gouvernement des Etats Unis ou toute entit qui d livre la licence de ce logiciel ou l utilise pour le compte du Gouvernement des Etats Unis la notice suivante s applique U S GOVERNMENT RIGHTS Programs software databases and related documentation and technical data delivered to U S Government customers are commercial computer software or commercial technical data pursuant to the applicable Federal Acquisition Regulation and agency specific Pell aa regulations As such the use duplication disclosure modification and adaptation shall be subject to the restrictions and license terms set forth in the applicable Government contract and to the extent applicable by the terms of the Government contract the additional rights set forth in FAR 52 227 19 Commercial Computer Software License December 2007 Oracle America Inc 500 Oracle Parkway Redwood City CA 94065 Ce logiciel ou mat riel a t d velopp pour un usage g n ral dans le cadre d applications de gestion des informations Ce logiciel ou mat riel n est pas con u ni n est destin a tre utilis dans des applications risque notamment dans des applications pouvant causer des dommages corporels Si vous utilisez ce logiciel ou mat riel dans le cadre d applications dangereuses il est de votre responsabilit de prendre
149. will take some time Please wait I AA A A A A EE E E E E a E EEEE E I Topology matching results I BA a A A A A A A A A A A a a a a eee A a I The topology defined in ib_topology topo perfectly matches the discovered fabric Related Information m generatetopology Command on page 27 m showtopology Command on page 50 m Linux Shells for Hardware Commands on page 3 setcontrolledhandover Command Enables or disables controlled handover Syntax setcontrolledhandover state list where state is either TRUE or FALSE 38 Sun Datacenter InfiniBand Switch 36 Command Reference April 2011 Description This hardware command enables or disables the controlled handover feature The TRUE option enables and the FALSE option disables the action The list option provides a listing of the Subnet Manager settings in respect to priority controlled handover and subnet prefix Note You must stop or disable the OpenSM Subnet Manager before using the setcontrolledhandover command See disablesm Command on page 17 The InfiniBand specification identifies two parameters used to negotiate a master Subnet Manager the Subnet Manager priority and the port GUID Should two or more Subnet Managers have the same highest configured priority the Subnet Manager with the lowest GUID becomes the master Subnet Manager If an un controlled or automatic handover state exists when the primary and master Subn
150. y 3 Creating config file template tmp osm conf Log File var log opensm log Understanding Hardware Commands 43 The following example shows how to display the current settings of the Subnet Manager priority controlled handover and subnet prefix with the list option of the setsubnetprefix command setsmpriority list Current SM settings smpriority 0 controlled_handover FALSE subnet_prefix 0xfe80000000000000 Related Information m enablesm Command on page 21 m setcontrolledhandover Command on page 38 m setsubnetprefix Command on page 44 m Linux Shells for Hardware Commands on page 3 setsubnetprefix Command Sets the subnet prefix Syntax setsubnetprefix prefix list where prefix is the hexadecimal prefix Description This hardware command sets the subnet prefix for the InfiniBand fabric The prefix is entered in hexadecimal starting with 0x and having lower case alphanumeric characters The list option provides a listing of the Subnet Manager settings in respect to priority controlled handover and subnet prefix The setsubnetprefix command writes the value of prefix to the subnet_prefix parameter of the etc opensm opensm conf file 44 Sun Datacenter InfiniBand Switch 36 Command Reference April 2011 Note You must stop or disable the OpenSM Subnet Manager before using the setsubnetprefix command See disablesm Command on page 17 The s
151. y the hardware and environmental status of the switch with the env_test command env_test Environment test started Starting Environment Daemon test Environment daemon running Starting Voltage test Voltage ECB OK Measured 3 3V Main 3 28 V Measured 3 3V Standby 3 37 V Measured 12V 12 06 V Measured 5V 5 03 V Measured VBAT 3 25 V Measured 2 5V 2 52 V Measured 1 8V 1 80 V Measured 14 1 2V 1 22 V Voltage test returned OK Starting PSU test PSU 0 present OK PSU 1 present OK PSU test returned OK Starting Temperature test Back temperature 28 Front temperature 29 SP temperature 35 Environment Daemon test returned OK Switch temperature 34 maxtemperature 36 Temperature test returned OK Starting FAN test Fan 0 not present Fan 1 running at rpm 11212 Fan 2 running at rpm 11313 Fan 3 running at rpm 11521 Fan 4 not present FAN test returned OK Starting Connector test Connector test returned OK Starting onboard ibdevice test Switch OK All Internal ibdevices OK onboard ibdevice test returned OK Environment test PASSED Understanding Hardware Commands 25 Related Information m checkpower Command on page 8 m checkvoltages Command on page 11 m showtemps Command on page 49 a getfanspeed Command on page 28 m connector Command on page 12 m checkboot Command on page 6 m Linux Shells for Hardware Commands on page 3 exit C
152. ys state 5 LinkUp rate 40 Gb sec 4X QDR Related Information m ibstatus man page 108 Sun Datacenter InfiniBand Switch 36 Command Reference April 2011 ibswitches Command Displays InfiniBand switch node in the topology Syntax ibswitches h topology C ca_name P ca_port t timeout where m topology is the topology file m ca_name is the channel adapter name m ca_port is the channel adapter port m timeout is the timeout in milliseconds Description This InfiniBand command is a script the discovers the InfiniBand fabric topology or uses an existing topology file to extract the switch nodes The ibswitches command is available from the SYS Switch_Diag and SYS Fabric_Mgmt Linux shell targets of the Oracle ILOM CLI interface Options The following table describes the options to the ibswitches command and their purposes Option Purpose h Provides help c Uses the specified channel adapter name P Uses the specified channel adapter port t Overrides the default timeout Understanding InfiniBand Commands 109 Example The following example shows how to display the switch GUIDs with the ibswitches command Note The output for your InfiniBand fabric will greatly differ from that in the example ibswitches Switch 0x0021283a8389a0a0 ports 36 Sun DCS 36 QDR switch localhost enhanced port 0 lid 15 Imc O Related Information m ibswitches man page m
153. yte mask Description This InfiniBand command uses the performance management GMPs to acquire the PortCounters or PortExtendedCounters from the Performance Manager agent at the node or port specified Note The data values retrieved from PortCounters and PortExtendedCounters are represented as octets divided by 4 Note Providing a port value of 255 ensures that the operation is performed on all ports The perfquery command is available from the SYS Switch_Diag and SYS Fabric_Mgmt Linux shell targets of the Oracle ILOM CLI interface Options The following table describes the options to the perfquery command and their purposes Option Purpose d Sets the debug level Can be used several times to increase the debug level Understanding InfiniBand Commands 115 116 Option Purpose e Shows extended port counters a Shows aggregate counters for all ports G Uses the port GUID address h Provides help 1 Loops through all ports r Resets the counters after reading R Resets counters only v Provides verbose output V Displays the version information C Uses the specified channel adapter name P Uses the specified channel adapter port t Overrides the default timeout Example The following example shows how to display all port counters for LID 15 port 23 with the perfquery command perfquery 15 23 Port counters Lid 15 port 23 PortSeleltiias S
Download Pdf Manuals
Related Search
Related Contents
取扱説明書 ST 167 "BETTA" BUSCADOR RECEPTOR Visualisez à la perfection avec l`ELMO P10 Epson DS-40 User's Guide BENDIX BW1624 User's Manual Bedienungsanleitung/Garantie Fettanalysewaage PW -Las jambas de la contra vienen preparadas y MELSECNET/H Network Module User's Manual(Hardware) Epson CX7800 Product Brochure BMW 530i Automobile User Manual Copyright © All rights reserved.