Home
Sun Blade X6275 Server Module Installation Guide
Contents
1. 3 Type your user name and password Tip The default ILOM administrator account user name is root and the password is changeme If this default administrator account which was shipped with each server module SP and CMM has been changed contact your system administrator for an ILOM user account with administrator privileges Chapter 3 Setting Up ILOM 23 24 4 Click Log In The web interface Versions page appears User root Role aucro SP Hostname mpk12 1200 42 237 Sun Integrated Lights Out Manager System Information Versions Session Time Out Components Fault Management Identification Information Versions View the version of ILOM firmware currently in use Version Information Property Value SP Firmware Version 3 0 410 SP Firmware Build Number 46759 SP Firmware Date Fri Jul 10 14 54 13 PDT 2009 SP Filesystem Version 0 1 22 You are now logged in to the SP ILOM Refer to the ILOM documentation for more information on how to use the web interface to configure the ILOM Log In to SP ILOM From a Serial Connection You will need a dongle cable The dongle cable might be shipped with the Sun Blade chassis To log in to the ILOM from a serial console connection 1 Use a dongle cable to connect a serial console to a UCP port on the front of the server module There are two UCP ports one for each node SP connection For more information refer
2. Address 25 v Configure a Static IP Address 26 About Installing a Supported OS 27 Flash Modules 28 USB Flash Disk 28 iv Sun Blade X6275 Server Module Installation Guide August 2009 Preface The Sun Blade X6275 Server Module Installation Guide contains procedures for installing the server module in a chassis and connecting to the service processor administrator account Related Documents To see a list of the Sun Blade X6275 server module documentation refer to the Getting Started Guide that is packed with your system and also posted at the product s documentation site Translated versions of some of these documents are available at the web product documentation page in Simplified Chinese French and Japanese English documentation is revised more freguently and might be more up to date than the translated documentation See TABLE P 1 for more information Sun Online TABLEP 1 Sun Blade X6275 Server Module Online Pages Sun Function URL Description Sun Documentation Support Training Warranty Feedback Product Updates http docs sun com http www sun http www sun http www sun warranty index http www sun http www sun com support com training com service support html com hwdocs feedback com download You can navigate to the Sun Blade X6275 server module document page and then download PDF and view HTML documents Obtain technical
3. Blade 0 BLO BL1 BL2 BL3 BL4 BL5 BL6 BL7 BL8 BLY BL10 BL11 1 BL12 BL13 BL14 BL15 BL16 BL17 BL18 BL19 BL20 BL21 BL22 BL23 The CMM ILOM displays information about the server module including its IP address and MAC address For example gt show CH BLO SP network CH BLO SP network Targets Properties type Network Configuration commitpending Cannot show property ipaddress IPaddress ipdiscovery dhcp ipgateway IPgateway ipnetmask 255 255 255 0 macaddress Macaddress pendingipaddress IPaddress pendingipdiscovery dhcp pendingipgateway lPgateway pendingipnetmask 255 255 255 0 state enabled Commands cd set show 4 Proceed to Accessing SP ILOM on page 22 Chapter 3 Setting Up ILOM 21 22 Accessing 5P ILOM Choose one of the following procedures to log in to the SP ILOM m Log In to SP ILOM Using the CLI on page 22 Recommended m Log In to SP ILOM Using the Web Browser User Interface on page 23 m Log In to SP ILOM From a Serial Connection on page 24 Log In to SP ILOM Using the CLI To log in to the SP ILOM from an Ethernet connection using the CLI command line interface 1 Obtain the ILOM IP address If you do not know the ILOM s IP address see Displaying the Service Processor s ILOM IP Address on page 19 to find the ILOM s IP address using the CMM ILOM 2 Open a new terminal window as reguired 3 Log in to SP
4. ILOM using secure shell SSH session Type the administrator account user name root the password changeme and the server module SP IP address For example ssh root 192 168 25 25 ssh root 192 168 25 25 password changeme gt Tip The default ILOM administrator account user name is root and the password is changeme If this default administrator account which was shipped with each server module SP and CMM has been changed contact your system administrator for an ILOM user account with administrator privileges You are now logged in to the SP ILOM Refer to the ILOM documentation for more information on how to use the CLI interface to configure the ILOM Sun Blade X6275 Server Module Installation Guide e August 2009 V Log In to SP ILOM Using the Web Browser User Interface Note To improve response times disable the browser proxy server if used To log in to the SP ILOM from an Ethernet connection using the web browser user interface 1 Obtain the SP ILOM IP address for the node If you do not know the node s ILOM IP address see Displaying the Service Processor s ILOM IP Address on page 19 to find the ILOM s IP address using the CMM ILOM 2 To log in to the web interface type the IP address of ILOM into your web browser The web interface Login page appears Sun Integrated Lights Out Manager SP Hostname mpk12 1200 42 237 User Name or Password
5. by Sun service technicians place components on an antistatic surface such as an antistatic discharge mat an antistatic bag or a disposable antistatic mat Wear an antistatic grounding strap connected to a metal surface on the chassis when you work on system components 3 Locate and remove the relevant server module filler panel Pull the lever out to the open position and eject the filler panel Keep the filler panel for later use Caution If you are not installing a server module into a slot do not remove the server module filler panel from the slot The server module filler panel is reguired to meet FCC standards for electromagnetic interference EMI Do not operate the chassis with empty slots for more than 60 seconds Always insert a filler panel into an empty slot to reduce the possibility of module shutdown 4 Verify a STEADY ON green light on the Chassis OK power LED The light indicates that the system chassis is powered on If the Chassis OK green light is steady on then the Sun Blade 6048 or Sun Blade 6000 modular system chassis has power and is operational If the chassis has not been powered on refer to the system chassis documentation to power on the system chassis Note For CMM ILOM 2 0 3 13 systems a Sun Blade X6275 server module must be inserted into the chassis before you power on the chassis If the blade is not inside the chassis before you power on ILOM does not recognize node 1 For ILOM 3 0 syst
6. port per node on the back of the motherboard You must remove the blade from the chassis to access the USB ports When a USB flash disk is present it appears as a disk device and you can install a supported operating system on it To install a USB flash disk refer to the Sun Blade X6275 Server Module Service Manual USB flash disks with standard USB 2 0 interfaces can be obtained from third party sources Each Sun Blade X6275 server module can use two USB flash disks one per node The USB flash disks must be no larger than 2 7 mm wide and 32 0 mm long See FIGURE 3 3 FIGURE 3 3 USB Flash Disk Dimensions 2 mm MAX 32 0mm mx nn El Sun Blade X6275 Server Module Installation Guide e August 2009
7. support and download patches Learn about Sun courses Obtain specific details regarding your warranty Submit your comments Please include the title and part number of your document with your feedback Sun Blade X6275 Server Module Installation Guide part number 820 6977 11 Find the Hardware Drivers section and click x64 Servers r Workstations The Sun Blade X6275 server module site contains updates for firmware drivers and DVD CD ROM ISO images vi Sun Blade X6275 Server Module Installation Guide e August 2009 CHAPTER 1 Preparing to Install the Sun Blade X6275 Server Module This chapter contains the following topics m Server Module Installation Summary on page 2 m Before You Begin on page 2 m Opening the Box on page 4 a Commonly Used Terms on page 7 Server Module Installation Summary TABLE 1 1 summarizes how to install a Sun Blade X6275 server module into a Sun Blade 6048 or Sun Blade 6000 modular system chassis TABLE 1 1 Installation Task Summary Step Task See 1 Unpack the server module and any Opening the Box on page 4 optional components ordered for the e Sun Blade X6275 Server Module Getting Started Guide server from the shipping containers 2 Register the server module Locate the Go to this web site serial number on the label on top of http www sun com service warranty index xml reg the server module 3 If applicable install the option
8. Blade X6275 server module SP ILOM Remote console CLI Access the CMM CLI user interface to access the SP ILOM CLI user interface Note Recommended The remote connection chassis Ethernet ports provide both the CLI and the web browser user interface method to connect to ILOM e Remote console GUI Access the CMM ILOM web browser user interface Local serial console blade serial console Use a dongle cable to connect a serial console to a UCP port on the front of the server module There are two UCP ports one for each node s SP connection For more information refer to the Sun Blade X6275 Server Module Service Manual e Local serial console CMM serial console Connect a serial console to the serial port on the CMM Note For more information about how to attach a CMM management network cable and attaching other cables or devices to a CMM refer to the system chassis documentation 18 Sun Blade X6275 Server Module Installation Guide e August 2009 TABLE 3 1 ILOM Configuration Summary Step Task Description 5 Access an To configure an IP address in SP ILOM you must log in to ILOM with an administrator user account Log in to ILOM Configure an IP address Obtain additional ILOM information administrative account for Node 0 or Node 1 A preconfigured administrator account is shipped on each node on the server module This administrative account includes built in administrative privileges read and wri
9. NK FAST BLINK indicates that the server module SP is booting 0 125 seconds on 0 125 seconds off c The server module green OK LEDs on Node 0 and Node 1 illuminate a SLOW BLINK SLOW BLINK indicates that a server module node is booting 0 5 seconds on 0 5 seconds off d A STEADY ON green light on the Node 0 and Node 1 server module green OK LEDs indicates that the boot cycle is complete and the server module nodes are ready Note For SP ILOM 2 0 3 17 systems The server module green OK LEDs on Node 0 and Node 1 illuminate a SLOW BLINK SLOW BLINK indicates that the server module SP is booting 0 5 second on 0 5 seconds off Chapter 2 Installing and Powering On the Sun Blade X6275 Server Module 11 Note If the blade is in standby power mode the two server module green OK LEDs blink briefly once every 3 seconds Refer to the Sun Blade X6275 Server Module Diagnostics Guide Tip For additional LED information server module removal power procedures and front panel cable connection information refer to the Sun Blade X6275 Server Module Service Manual 12 Sun Blade X6275 Server Module Installation Guide e August 2009 FIGURE 2 2 Sun Blade X6275 Server Module Front Panel LEDs zZ o rm o nd as gt e O J a ec MOFOS GO 0 bb obs Figure Legend Node 0 and Node 1 Server Module LEDs 0 Node 0 1 Node 1 2 Server Module Locate LED Whi
10. RS amp UN microsystems Sun Blade X6275 Server Module Installation Guide Sun Microsystems Inc www sun com Part No 820 6977 11 Rev A August 2009 Submit comments about this document by clicking the Feedback link at http docs sun com Copyright 2009 Sun Microsystems Inc 4150 Network Circle Santa Clara California 95054 U S A All rights reserved This distribution may include materials developed by third parties Sun Sun Microsystems the Sun logo Sun Blade Sun Blade X6275 Server Module and Sun company logo are trademarks or registered trademarks of Sun Microsystems Inc or its subsidiaries in the U S and other countries Intel Intel Xeon and Intel Inside are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United States and other countries DOCUMENTATION IS PROVIDED AS IS AND ALL EXPRESS OR IMPLIED CONDITIONS REPRESENTATIONS AND WARRANTIES INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE OR NON INFRINGEMENT ARE DISCLAIMED EXCEPT TO THE EXTENT THAT SUCH DISCLAIMERS ARE HELD TO BE LEGALLY INVALID Copyright 2009 Sun Microsystems Inc 4150 Network Circle Santa Clara California 95054 Etats Unis Tous droits r serv s Cette distribution peut inclure des l ments d velopp s par des tiers Sun Sun Microsystems le logo Sun Sun Blade Sun Blade X6275 Server Module et Sun company logo sont des marques de fabr
11. Setting Up ILOM 19 20 CMM ILOM 3 0 show CH BLO NODE1 SP network where BL0 represents blade 0 and NODEI is node 1 To view the target blade and node you must specify the number of the blade in which the server module is installed and the node number The CMM ILOM displays information about the server module including its IP address and MAC address The following example shows Blade 0 Node 1 server module information gt show CH BLO NODE1 SP network CH BLO NODE1 SP network Targets Properties type Network Configuration commitpending Cannot show property ipaddress IPaddress ipdiscovery dhcp ipgateway IPgateway ipnetmask 255 255 255 0 macaddress Macaddress pendingipaddress IPaddress pendingipdiscovery dhcp pendingipgateway lPgateway pendingipnetmask 255 255 255 0 Commands cd set show Sun Blade X6275 Server Module Installation Guide e August 2009 CMM ILOM 2 0 3 13 show CH BL14 SP network where BL14 represents node 1 installed in slot 3 To specify the target CMM or blade you must specify the number of the slot in which the module is installed Each Sun Blade 6048 chassis shelf has 24 nodes maximum Blade nodes are numbered from 0 to 23 CMM Nodes 0 to 11 are blade node 0 and named BLO BL11 CMM nodes 12 to 23 are blade node 1 and named BL12 BL23 For a Sun Blade 6048 chassis the nodes display as Node Nodes Two per
12. al server Sun Blade X6275 Server Module Service Manual module components before you install e Optional component documentation the server module into the chassis 4 Install the server module into a Installing the Server Module Into a Chassis on page 9 powered on chassis 5 Obtain and configure the SP IP Setting Up ILOM on page 15 address 6 Install an operating system e About Installing a Supported OS on page 27 e Sun Blade X6275 Server Module Linux OS Installation Guide Sun Blade X6275 Server Module Windows OS Installation Guide Before You Begin Ensure that the following tasks are complete before you install the Sun Blade X6275 server module into the Sun Blade modular system 1 Review the reguired installation tasks for properly installing and setting up the Sun Blade X6275 server module in a Sun Blade 6048 or Sun Blade 6000 modular system See TABLE 1 1 Installation Task Summary on page 2 2 Review the safety documents m Important Safety Information for Sun Hardware Systems Printed 2 Sun Blade X6275 Server Module Installation Guide e August 2009 a Sun Blade X6275 Server Module Safety and Compliance Guide Available online at the Sun documentation web site 3 Ensure that the following chassis components have been installed and powered on in a Sun Blade 6048 or Sun Blade 6000 modular system a Chassis Monitoring Module CMM All required power and data cables to the chassis are attached a Choose the corre
13. ct Sun Blade X6275 server module model for the chassis Refer to the Sun Blade X6275 Server Module Product Notes a Choose a supported NEM for the choice of Sun Blade X6275 server module Refer to the Sun Blade X6275 Server Module Product Notes Note For CMM ILOM 2 0 3 13 systems a Sun Blade X6275 server module must be inserted into the chassis before you power on If the blade is not inside the chassis before you power on ILOM does not recognize node 1 For ILOM 3 0 systems this requirement does not apply For information about installing chassis components attaching cables and powering on the chassis refer to the Sun Blade 6048 or Sun Blade 6000 modular system chassis documentation at http docs sun com app docs prod blade srvr hic For information about Q NEMs on the chassis go to http docs sun com app docs prod blade 6048mod blade6048 hic 4 Assemble all tools and equipment needed To install the system you must have the following tools Electrostatic discharge ESD mat and antistatic grounding strap required if you install optional components In addition you must provide a system console device such as one of the following a Notebook PC a ASCII terminal Sun workstation Terminal server 5 See Opening the Box on page 4 Chapter 1 Preparing to Install the Sun Blade X6275 Server Module 3 Opening the Box 1 Carefully open the shipping box 2 Unpack all server components from the
14. e SP TABLE 3 1 ILOM Configuration Summary Step Task Description 1 Install the server Install the server module in the system chassis as described in Chapter 1 and module in chassis Check the chassis Check the power Obtain the CMM SP ILOM IP address Obtain the server module SP ILOM IP address Establish a console connection to the SP ILOM Chapter 2 of this guide Note For CMM ILOM 2 0 3 13 systems a Sun Blade X6275 server module must be inserted into the system chassis before you power on the chassis If the blade is not inside the chassis before you power on ILOM does not recognize node 1 For ILOM 3 0 systems this reguirement does not apply Ensure that e The system chassis is powered up The CMM ILOM is connected to the network and is working correctly The installer has Ethernet access to the same subnet as the CMM ILOM Ensure that the Sun Blade X6275 server module has standby power If you are using ILOM CLI commands and you do not know the ILOM s IP address see Displaying the Service Processor s ILOM IP Address on page 19 to find the CMM SP ILOM s IP address using the CMM ILOM If you are using ILOM CLI commands and you do not know the ILOM s IP address see Displaying the Service Processor s ILOM IP Address on page 19 to find the Sun Blade X6275 server module SP ILOM s IP address using the CMM ILOM Choose one of the following methods to establish a connection with the Sun
15. ems this reguirement does not apply 5 Check the rear of the system chassis to ensure that all power cords have been installed and connected to the mains 6 Check that full power is available Verify that the system chassis Power Supply AC OK and DC OK LEDs illuminate steady green 7 Position the server module vertically so that the ejectors are on the right and extend outward FIGURE 2 1 shows the server module being inserted into the Sun Blade 6048 or Sun Blade 6000 modular system Your chassis might differ 8 Push the server module into the slot until the server module stops and is flush with the chassis See FIGURE 2 1 1 10 Sun Blade X6275 Server Module Installation Guide e August 2009 FIGURE 2 1 Inserting the Server Module Into the Chassis Sun Blade 6048 Modular System shown 9 Lock the server module into the chassis Rotate the top ejector down while rotating the bottom ejector up until they both latch into place See FIGURE 2 1 2 The server module is now locked in the chassis 10 Verify that the server module s LEDs illuminate as follows See FIGURE 2 2 a After you plug in the blade all four server module LEDs on each Node blink three times When the front panel lights on the server module blink three times after the blade is inserted then the blade has been powered on and the SP boot process starts b The server module green OK LEDs on Node 0 and Node 1 illuminate a FAST BLI
16. ique ou des marques enregistr es de Sun Microsystems Inc ou ses filiales aux Etats Unis et dans d autres pays Intel Intel Xeon and Intel Inside sont des marques de fabrique ou des marques enregistr es d Intel Corporation ou de ses filiales aux Etats Unis et dans d autres pays LA DOCUMENTATION EST FOURNIE EN L ETAT ET TOUTES AUTRES CONDITIONS DECLARATIONS ET GARANTIES EXPRESSES OU TACITES SONT FORMELLEMENT EXCLUES DANS LA MESURE AUTORISEE PAR LA LOI APPLICABLE Y COMPRIS NOTAMMENT TOUTE GARANTIE IMPLICITE RELATIVE A LA QUALITE MARCHANDE A L APTITUDE A UNE UTILISATION PARTICULIERE OU A L ABSENCE DE CONTREFACON Sd mon Ca Adobe PostScript Contents Preface v Preparing to Install the Sun Blade X6275 Server Module 1 Server Module Installation Summary 2 Before You Begin 2 Opening the Box 4 About Your Server Module Shipment 6 Additional Options and Replaceable Components 6 Commonly Used Terms 7 Installing and Powering On the Sun Blade X6275 Server Module 9 Installing the Server Module Into a Chassis 9 Setting UpILOM 15 Preparing to Access and Configure LOM 15 About CMM ILOM 16 About SPILOM 17 ILOM Setup Task Summary 18 Displaying the Service Processor s ILOM IP Address 19 Accessing SP ILOM 22 v LogIntoSPILOMUsingtheCLl 22 v Log In to SP ILOM Using the Web Browser User Interface 23 v LogIn to SP ILOM From a Serial Connection 24 Configuring an IP Address for SP Network Configuration 25 v Configure a DHCP IP
17. log out of ILOM type exit Refer to the ILOM documentation for more information on how to use the ILOM CLI interface You can now load the operating system See About Installing a Supported OS on page 27 Configure a Static IP Address If you plan to assign static IP addresses to a server SP do the following procedure for each node 1 Verify that an Ethernet cable is connected to the Ethernet port NET MGT port on the CMM 2 Obtain the CMM ILOM IP address If you do not know the ILOM s IP address see Displaying the Service Processor s ILOM IP Address on page 19 to find the ILOM s IP address using the CMM ILOM Sun Blade X6275 Server Module Installation Guide e August 2009 3 Log in to CMM ILOM Choose one of the following procedures m Log In to SP ILOM Using the CLI on page 22 m Log In to SP ILOM From a Serial Connection on page 24 4 Configure a static Ethernet configuration Use your own addresses in place of the examples below gt cd CH BL4 NODE1 SP network gt set pendingipaddress 129 144 82 26 gt set pendingipnetmask 255 255 255 0 gt set pendingipgateway 129 144 82 254 gt set pendingipdiscovery static gt set commitpending true 5 To log out of ILOM type exit Refer to the ILOM documentation for more information on how to use the ILOM CLI interface You can now load the operating system See About Installing a Supported OS on page 27 About Installi
18. manage the components installed in your system chassis and server modules See FIGURE 3 2 ILOM enables you to Configure network information m View and edit hardware configurations for the SP m Monitor vital system information m Manage user accounts Note For CMM ILOM 2 0 3 13 systems a Sun Blade X6275 server module must be inserted into the system chassis before you power on the chassis If the blade is not inside the chassis before you power on ILOM does not recognize node 1 For ILOM 3 0 systems this reguirement does not apply For detailed ILOM information refer to the Integrated Lights Out Manager documentation FIGURE 3 2 SP ILOM Web Interface Page via CMM ILOM 3 0 system User root Rol MM Hostname mpk12 1200 Sun Integrated Lights Out Manager G Chassis CMM Blade 0 Node 1 Blade 1 Blade 2 Blade 3 Blade 4 Blade 6 Blade 7 Blade 9 Blade 10 Blade 11 System Information Versions Components Fault Management Identification Information Versions View the version of ILOM firmware currently in use Version Information Property Value SP Firmware Version 3 0 4 10 SP Firmware Build Number 46759 SP Firmware Date Fri Jul 10 14 54 13 PDT 2009 SP Filesystem Version 0 1 22 Chapter 3 Setting Up ILOM 17 ILOM Setup Task Summary TABLE 3 1 summarizes how to set up ILOM and configure an IP address on the server modul
19. mpk12 Sun Integrated Lights Out Manager CMM Blade 0 Blade 1 Blade 2 Blade 3 Blade 4 Blade 6 Blade 7 Blade 9 Blade 10 Blade 11 gt gt gt Chassis View To manage a Blade or Chassis Monitoring Module click on it in the left navigation pane or in the image below Chassis Inventory Component Name Part Number Serial Number ICH SUN BLADE 6048 MODULAR SYSTEM 540 7545 01 0111APO 0825YMO34E ICHICMM pi JCHIBLO SUN BLADE X6275 SERVER MODULE 000 0000 00 0000000000 ICHIBL1 ASSY BLADE X6275 542 0162 01 0328MSL 09288W0009 JCHIBL2 SUN BLADE X6275 SERVER MODULE 000 0000 00 0000000000 ICHIBL3 SUN BLADE X6275 SERVER MODULE 000 0000 00 0000000000 ICHIBL4 ASSY BLADE X6275 542 0162 01 0328MSL 0928BW0008 JCHIBL6 SUN BLADE X6275 SERVER MODULE 000 0000 00 0000000000 ICHIBL7 SUN BLADE X6275 SERVER MODULE 000 0000 00 0000000000 JCH BL9 SUN BLADE X6275 SERVER MODULE 000 0000 00 0000000000 ICHIBL10 SUN BLADE X6275 SERVER MODULE 000 0000 00 0000000000 JCHIBL11 SUN BLADE X6275 SERVER MODULE 000 0000 00 0000000000 ICHINEM1 ASSY SB6048 QDR NEM 541 3378 01 01105JC 0906CA0053 16 Sun Blade X6275 Server Module Installation Guide e August 2009 About SP ILOM The Sun Blade X6275 server module includes two service processor SP ILOMs that reside on a separate board Each node has a dedicated SP You can use the ILOM built in system management software to monitor and
20. ng a Supported OS Choose one of the following methods to install a supported Operating System OS on a Sun Blade X6275 server module m Install the OS on a Flash Module Flash Modules can support some operating systems See Flash Modules on page 28 m Install the OS on USB Flash Disk See USB Flash Disk on page 28 m Configure diskless network boot to load the OS to the server module from a boot image on another server Refer to your operating system vendor s documentation for specific information Refer to the Sun Blade X6275 Server Module Linux OS Installation Guide or Sun Blade X6275 Server Module Windows OS Installation Guide for more detailed instructions and supported OSes for operating system installation Chapter 3 Setting Up ILOM 27 28 Flash Modules The Sun Blade X6275 server module supports one flash module FMod per node that can install and boot a supported operating system You can use flash modules to install an operating system locally To install flash modules refer to the Sun Blade X6275 Server Module Service Manual Caution Do not remove or insert the flash module until the green LED goes out Damage to the flash module can occur if the FMod is removed while the green LED next to the FMod slot is lit Wait for twenty seconds for the LED to go out Do not remove or apply AC power while removing or inserting a flash module USB Flash Disk The Sun Blade X6275 server module has one internal USB
21. onal information about ILOM refer to the Integrated Lights Out Manager documentation SP Embedded service processor SP on the server module and Chassis Monitoring Module CMM The SP is a baseboard management controller BMC Each of the two servers on the server blade has its own dedicated SP CMM Chassis Monitoring Module A baseboard management controller BMC for the entire Sun modular system chassis FMod Flash Module EM Express Module IB InfiniBand IB NEM InfiniBand Network Express Module Chapter1 Preparing to Install the Sun Blade X6275 Server Module 7 Sun Blade X6275 Server Module Installation Guide e August 2009 CHAPTER 2 Installing and Powering On the Sun Blade X6275 Server Module This chapter contains the following topic a Installing the Server Module Into a Chassis on page 9 Installing the Server Module Into a Chassis To install the Sun Blade X6275 server module into a Sun Blade 6048 or Sun Blade 6000 modular system chassis 1 Perform all steps and fufill all reguirements in Preparing to Install the Sun Blade X6275 Server Module on page 1 2 Attach a grounded antistatic wrist strap foot strap or eguivalent safety eguipment to prevent electrostatic discharge ESD when you install the Sun Blade server module into the system chassis Caution To protect electronic components from electrostatic damage which can permanently disable the system or reguire repair
22. onents that you purchase independent of the standard configuration are shipped separately and in most cases should be installed before you install the server module into the chassis For optional components available for the Sun Blade X6275 server module see Additional Options and Replaceable Components on page 6 If you ordered any options that are field replaceable units FRUs or Customer Replaceable Units CRUs refer to the Sun Blade X6275 Service Label on the top cover or the Sun Blade X6275 Server Module Service Manual for installation instructions If you ordered any options that are not factory installed refer to the documentation provided with the option for installation instructions On a Sun Blade 6048 Modular System the Sun Blade X6275 Service Card with a center tab is located in a slot on the front right side of the system chassis rack along with the Sun Blade 6048 Modular System Chassis Service Card A service label on the blade cover will replace the Service Card Note These servers are fully compliant with the Reduction of Hazardous Substances RoHS Directive Additional Options and Replaceable Components Optional components are shipped separately for customer installation Supported components and their part numbers are subject to change over time and without notice For the most up to date list go to http sunsolve sun com handbook_pub Systems Click the name and model of your server On the produc
23. packing carton See FIGURE 1 1 and FIGURE 1 2 FIGURE 1 1 Shipping Box Contents Multiple Blades Figure Legend 1 Documentation Server module Shipping box A o N Shipping label Sun Blade X6275 Server Module Installation Guide e August 2009 FIGURE 1 2 Shipping Box Contents Single Blade 20 6 Ibs 9 36 kg Figure Legend 1 Documentation 2 Server module 3 Shipping box 4 Shipping label 3 If applicable install optional server module components prior to installing the server module into the system chassis Example DIMMs FMods USB flash disks For optional components available for the Sun Blade X6275 server module see Additional Options and Replaceable Components on page 6 Also see About Your Server Module Shipment on page 6 Refer to the Sun Blade X6275 Server Module Service Manual for installation procedures of optional components 4 Register the server module Locate the serial number on the label on top of the server module To register go to this web site http www sun com service warranty index xml reg 5 Proceed to Installing and Powering On the Sun Blade X6275 Server Module on page 9 Chapter 1 Preparing to Install the Sun Blade X6275 Server Module 5 About Your Server Module Shipment Configurations for the Sun Blade X6275 server module are assembled at the factory and shipped ready for installation in a Sun Blade modular system Optional server module comp
24. page 15 m Displaying the Service Processor s ILOM IP Address on page 19 m Accessing SP ILOM on page 22 m Configuring an IP Address for SP Network Configuration on page 25 m About Installing a Supported OS on page 27 Preparing to Access and Configure ILOM The ILOM Integrated Lights Out Manager allows you to manage the system chassis using the CMM ILOM and manage the Sun Blade X6275 server module nodes using the SP ILOM This section contains the following topics About CMM ILOM on page 16 m About SP ILOM on page 17 ILOM Setup Task Summary on page 18 ILOM software provides a command line interface CLI and a web browser user interface For detailed ILOM information refer to the Integrated Lights Out Manager documentation About CMM ILOM Each system chassis has its own service processor called a Chassis Monitoring Module Integrated Lights Out Manager CMM ILOM CMM ILOM provides an Ethernet connection to the server module s service processor and allows you to view and configure the Sun Blade X6275 server module s network information See FIGURE 3 1 Supported CMM ILOM versions are CMM ILOM 2 0 3 13 only for ILOM 2 0 blades CMM ILOM 3 0 6 11 or later for ILOM 3 0 Refer to the system chassis documentation for more information Go to http docs sun com app docs prod blade srvr hic FIGURE 3 1 CMM ILOM Web Interface Page REFRESH LOG OUT cro CMM Ho ne
25. t page that opens for the server click on Full Components List for a list of components The following optional server module components may be ordered and purchased separately m CPU Assembly Options DDR3 Memory Kits m Flash Modules FMods m Dongle Cable Sun Blade X6275 Server Module Installation Guide e August 2009 m Operating System Software m Printed Documentation m Software Discs Commonly Used Terms The following table identifies some terms commonly used in this guide to describe the installation of a Sun Blade X6275 server module into a Sun Blade modular system chassis TABLE 1 2 Commonly Used Terms Term Definition Server Module Sun Blade X6275 server module hardware The X6275 Blade Server Module which is the physical blade that plugs into a Sun modular system chassis The Sun Blade X6275 server module contains two independent nodes Node Either of the two independent x64 computers resident on the server blade Chassis Sun Blade 6048 modular system or Sun Blade 6000 modular system hardware For additional information about the Sun Blade 6048 modular system go to http docs sun com app docs coll blade6048 For additional information about the Sun Blade 6000 modular system go to http docs sun com app docs coll blade6000 ILOM Integrated Lights Out Manager ILOM is the embedded management software that runs on the server module SP and CMM SP that enables you to manage your system For additi
26. te x Press button to identify server 3 Ready to Remove Server Module LED Blue main power removed 48 4 Server Module Service Action Required LED Amber 5 Server Module OK LED Green Note Full power steady on Updating slow blink 0 5 second on 0 5 second off SP booting fast blink 0 125 second on 0 125 second off Node booting slow blink 0 5 second on 0 5 second off Standby power blink 0 1 second on 2 9 seconds off O Caution Pressing Power Button for more than 4 seconds when in full power initiates immediate shutdown to standby power May cause data loss 6 Server Module Power Button Momentary press to toggle server between standby and full power 7 Non Maskable Interrupt NMI button Caution Service use only Do not press unless instructed by Sun personnel 8 Universal Connector Port UCP Used for dongle cable The physical installation is complete 11 Set up the ILOM SP on each node 0 and 1 See Setting Up ILOM on page 15 Chapter 2 Installing and Powering On the Sun Blade X6275 Server Module 14 Sun Blade X6275 Server Module Installation Guide e August 2009 CHAPTER 3 Setting Up ILOM This chapter describes how to access the Sun Integrated Lights Out Manager ILOM software and how to configure an IP address for the Sun Blade X6275 server module Service Processor SP This chapter contains the following topics m Preparing to Access and Configure ILOM on
27. te access to all SP features and commands The user name is root and the password is changeme Tip It is highly recommended that you change the password after initial setup for security reasons For more information about ILOM s user accounts refer to the Integrated Lights Out Manager documentation Choose one of the following procedures to log in to ILOM e Log In to SP ILOM Using the CLI on page 22 e Log In to SP ILOM Using the Web Browser User Interface on page 23 e Log In to SP ILOM From a Serial Connection on page 24 Choose one of the following procedures optional e Configure a DHCP IP Address on page 25 e Configure a Static IP Address on page 26 You might need to obtain additional information about ILOM if applicable For more information about configuring or modifying an IP address in ILOM refer to the Integrated Lights Out Manager documentation Displaying the Service Processor s ILOM IP Address Use the following CLI procedure to display the ILOM s network configuration including the IP address of the ILOM SP using the CMM ILOM Note You can also obtain node SP IP addresses from Web interface of the CMM This procedure also verifies that the ILOM is working correctly and that you can access it through the CMM ILOM 1 Access the CMM ILOM 2 Log in to the CMM ILOM CLI 3 Type one of the following commands depending on the CMM ILOM revision Chapter 3
28. to the Sun Blade X6275 Server Module Service Manual Verify that your serial console connection to the Sun Blade X6275 server module is secure and operational Ensure that the following serial communication settings are configured m 8N1 eight data bits no parity one stop bit m 9600 baud default do not change m Disable hardware flow control CTS RTS Sun Blade X6275 Server Module Installation Guide e August 2009 4 Press Enter to establish a connection between your serial console and ILOM A login prompt to ILOM appears 5 Log in to the ILOM CLI using an administrator account Type a user name and password for the administrator account Tip The default ILOM administrator account user name is root and the password is changeme If this default administrator account which was shipped with each server module SP and CMM has been changed contact your system administrator for an ILOM user account with administrator privileges You are now logged in to the SP ILOM Refer to the ILOM documentation for more information on how to use the CLI interface to configure the ILOM Configuring an IP Address for SP Network Configuration You can configure a static or a dynamic IP address for SP Network Configuration Choose one of the following procedures m Configure a DHCP IP Address on page 25 m Configure a Static IP Address on page 26 Configure a DHCP IP Address DHCP is enabled in the factory default config
29. uration By default the SP uses a Dynamic Host Configuration Protocol DHCP server for network configuration To configure SP networks with a DHCP server 1 Verify that an Ethernet cable is connected to the Ethernet port NET MGT port on the CMM 2 Obtain the CMM ILOM IP address If you do not know the ILOM s IP address see Displaying the Service Processor s ILOM IP Address on page 19 to find the ILOM s IP address using the CMM ILOM Chapter 3 Setting Up ILOM 25 26 3 Log in to CMM ILOM Choose one of the following procedures m Log In to SP ILOM Using the CLI on page 22 Log In to SP ILOM From a Serial Connection on page 24 4 Obtain the DHCP IP address assigned to the server module SP Choose one of the following procedures to view the dynamic server module IP address that was assigned ILOM 3 0 system CMM Type show CH BLO NODE1 SP network where BLO represents the blade slot 0 node 1 ILOM 2 0 3 13 system CMM Type show CH BL0 SP network where BLO represents node 0 installed in slot BLO To specify the target CMM or blade you must specify the number of the slot in which the module is installed Blade nodes range from 0 to 23 Each shelf has 24 nodes numbered BLO to BL23 Slots BLO to BL11 are node 0 Slots BL12 to BL23 are node 1 5 To configure the SP to use DHCP type gt cd CH BL4 NODE1 SP network gt set pendingipdiscovery dhcp gt set commitpending true 6 To
Download Pdf Manuals
Related Search
Related Contents
Sony SDM-HX93 User's Manual Manual de usuario del equipo portátil Uniden BT110 User's Manual COMBICONTROL C-more Hardware User Manual Zotac ZT-88XE760-FPP GeForce 8800 GTX graphics card Montageanleitung - TAS Telefonbau Arthur Schwabe GmbH & Co. KG Conveyor Monitor User Manual Copyright © All rights reserved.