Home
Sun Fire V125 Server Getting Started Guide
Contents
1. The server has two USB ports for attaching supported devices External SCSI Port The SCSI port is a mulitmode Ultra160 SCSI interface To operate at Ultra160 SCSI speeds the port must be in LVD mode If a single ended device is connected to the server it automatically switches to single ended mode Introducing the Sun Fire V125 Server 9 Preinstalled Software Your Sun Fire V125 server is shipped with the Solaris 10 Operating System OS and the Java Enterprise System software You must configure the preinstalled software as part of the installation process However before you begin the configuration process go to http www sun com servers This site contains the latest information about the preinstalled software and links to the software updates and patches you must install OpenBoot PROM Diagnostics This product ships with OpenBoot PROM 4 22 17 or a subsequently compatible version of the OpenBoot PROM OpenBoot PROM diagnostics are enabled by default This ensures complete diagnostic test coverage on the initial boot and after error reset events This change results in increased boot time To change the system defaults and diagnostic settings after the initial boot refer to OpenBoot PROM Enhancements for Diagnostic Operation at http www sun com documentation Sun Advanced Lights Out Manager The Sun Fire V125 server ships with the Sun Advanced Lights Out Manager ALOM software installed The system console
2. in which you will install it for 24 hours This process prevents thermal shock and condensation The operating environmental limits in TABLE 3 reflect the limits to which the systems have been tested to meet all functional requirements Operating computer equipment in extremes of temperature or humidity increases the failure rate of hardware components To minimize the chance of component failure use the server within the optimal temperature and humidity ranges Ambient Temperature An ambient temperature range of 21 C 23 C 69 9 F 73 4 F is optimal for system reliability At 22 C 71 6 F it is easy to maintain safe relative humidity levels Operating in this temperature range provides a buffer in the event of the environmental support systems failing Ambient Relative Humidity Ambient relative humidity levels between 45 and 50 are the most suitable for data processing operations to m Provide an operating time buffer in the event of environmental control system failure m Help avoid failures caused by the intermittent interference from static discharges that occur when relative humidity is too low Electrostatic discharge ESD is easily generated and less easily dissipated in areas where the relative humidity is below 35 and becomes critical when levels drop below 30 Airflow Considerations The Sun Fire V125 server is self cooling when operated in still air Follow these guidelines m Ensure unobstructed
3. is directed to ALOM by default and is configured to show server console information on startup ALOM enables you to monitor and control your server over either a serial connection using the SERIAL MGT port or Ethernet connection using the NET MGT port For information about configuring an Ethernet connection refer to the Sun Advanced Lights Outs Manager Software ALOM 1 6 Administration Guide Note The ALOM serial port labeled SERIAL MGT is for server management only If you need a general purpose serial port use the serial port labeled 10101 10 Sun Fire V125 Server Getting Started Guide September 2006 ALOM can be configured to send email notification of hardware failures and other events related to the server or to ALOM The ALOM circuitry uses standby power from the server This means that ALOM is active as soon as the server is connected to a power source and remains active until power is removed by unplugging the power cable ALOM continues to be effective even when the operating system is offline and when the server is in Standby mode For more information about ALOM see the Sun Advanced Lights Out Management ALOM 1 6 Administration Guide Sun Fire V125 Server Documentation The following table summarizes important Sun Fire V125 server documentation The documents listed as online are available at http www sun com documentation TABLE8 Sun Fire V125 Server Documentation Appli
4. Continued Sun Fire V125 Feature PCI expansion One 64 bit 33 66 MHz 3 3 volt full length slot USB Two ports SCSI One UltraSCSI LVD port Hard drive SCSI One 73 gigabyte drive Power supply One For a detailed summary of features available configurations and compatible options go to http www sun com servers For detailed information about this server go to http sunsolve sun com See the Sun System Handbook 2 Server Installation Process This section contains a list of tasks that you must complete during the installation process Each task includes a reference to the appropriate instructions Each task must be completed in order 1 Preparing the site according to the power clearance and environmental requirements If you are installing the server into a new Sun rack you must fully prepare the site for the installation If you are installing the server into an existing rack you must conduct some site preparation to satisfy the additional power and environmental requirements See Site Preparation on page 3 for specific instructions 2 Verifying that you have received all of the components The Sun Fire V125 server ships in several packages See Shipping Kit Contents on page 7 for a list of the shipping kit 3 Installing the server into the rack Sun Fire V125 Server Getting Started Guide September 2006 4 Setting up a console to communicate with the server You can communi
5. S R SUN microsystems Sun Fire V125 Server Getting Started Guide Sun Microsystems Inc www sun com Part No 819 7423 10 September 2006 Rev A Submit comments about this document at http www sun com hwdocs feedback Copyright 2006 Sun Microsystems Inc 4150 Network Circle Santa Clara California 95054 U S A All rights reserved Sun Microsystems Inc has intellectual property rights relating to technology fiat is described in this document In particular and without limitation these intellectual property rights may include one or more of the U S patents listed at http www sun com patents and one or more additional patents or pending patent applications in the U S and in other countries This document and the product to which it pertains are distributed under licenses restricting their use copying distribution and decompilation No part of the product or of this document may be reproduced in any form by any means without prior written authorization of Sun and its licensors if any Third party software including font technology is copyrighted and licensed from Sun suppliers Parts of the produce may be derived from Berkeley BSD systems licensed from the University of California UNIX is a registered trademark in the U S and in other countries exclusively licensed through X Open Company Ltd Sun Sun Microsystems the Sun logo Sun Fire Java OpenBoot and Solaris are trademarks or registered trademarks of S
6. airflow through the chassis The Sun Fire V125 server uses internal fans that can achieve a total airflow of 30 cfm in normal operating conditions m Ensure that inlet air enters at the front of the server and exits from the back Introducing the Sun Fire V125 Server 5 6 m Ensure that entilation openings for both the inlet and exhaust of the system should provide a minimum open area of 85 cm 13 in each a Allow a minimum of 88 9 mm 3 5 inches clearance at the front and back of the servers when mounted unless an unobstructed airflow can be ensured Acoustic Noise TABLE 4 shows the amount of acoustic noise generated by the Sun Fire V125 Server TABLE4 Acoustic Noise Operating Idling LWAm 1B 10dB 7 4B 7 2B LpAm 64 2dBA 62 2dBA Operating Power Limits and Ranges The table shows the operating power for the Sun Fire V125 server TABLE5 Operating Power Limits and Ranges for the Sun Fire V125 Server Description Sun Fire V125 Server Operating input voltage range 90 264 Volts Operating frequency range 47 63 Hz Maximum operating current 3 58 Amps 90 VAC Maximum AC input 459 Watts Calculating Power Consumption The estimated power consumed in a fully powered server depends on the configuration of the server For more information on calculating power consumption go to the following site http www sun com servers Sun Fire V125 Server Getting Started Guide September 2006 Calculating Heat Diss
7. cate with the Sun Fire server using either a TIP connection from another server or an ASCII terminal connected to the SERIAL MGT port To set up the console refer to the Sun Fire V125 Server Installation Guide for instructions 5 Powering on the server and configuring the preinstalled software The Solaris 10 OS and the Java Enterprise System is preinstalled on the server When you power the server on you will automatically be taken through the Solaris OS configuration procedure However you must first go to the preinstalled software site to download and install the latest updates and patches To power on the server and configure the preinstalled software refer to the Sun Fire V125 Server Installation Guide for instructions 6 Setting the desired OpenBoot PROM configuration options The initial boot will test the entire system You can change the level of testing by using the OpenBoot PROM commands and configuration variables To change the boot test level and other boot variables refer to the OpenBoot PROM Enhancements for Diagnostic Operation 7 Loading additional software from the Solaris OS media kit optional The Solaris OS media kit includes several CDs containing software to help you operate configure and administer your server Refer to the documentation provided with the media kit for a complete listing of included software and detailed instructions Site Preparation Before you install the Sun Fire server y
8. cation Title Part Number Format Location Getting Started Sun Fire V125 Server Getting Started Guide 819 7423 PDF and Online HTML Installation Sun Fire V125 Server Installation Guide 819 7422 PDF and Online HTML Administration Sun Fire V125 Server Administration Guide 819 7420 PDF and Online HTML Service Sun Fire V125 Server Service Manual 819 7421 PDF and Online HTML Safety and Sun Fire V125 Safety and Compliance 817 7425 PDF and Online Compliance Manual HTML Late breaking Sun Fire V125 Server Product Notes 819 7424 PDF and Online news HTML OpenBoot PROM OpenBoot PROM Enhancements for 817 6957 PDF Online Diagnostic Operation ALOM Sun Advanced Lights Out Manager ALOM 819 2445 PDF and Online 1 6 Guide HTML Introducing the Sun Fire V125 Server 11 Documentation Support and Training Sun Function URL Documentation http www sun com documentation Support http www sun com support Training http www sun com training Third Party Web Sites Sun is not responsible for the availability of third party web sites mentioned in this document Sun does not endorse and is not responsible or liable for any content advertising products or other materials that are available on or through such sites or resources Sun will not be responsible or liable for any actual or alleged damage or loss caused by or in connection with the use of or reliance on any such content goods or services that are available on or through such sites or r
9. eat Dissipation 7 Shipping Kit Contents 7 Power Inlets and I O Ports 7 Power 8 Ethernet Ports 8 Serial Ports 9 USB Ports 9 External SCSI Port 9 Preinstalled Software 10 OpenBoot PROM Diagnostics 10 Sun Advanced Lights Out Manager 10 Sun Fire V125 Server Documentation 11 Third Party Web Sites 12 Sun Welcomes Your Comments 12 iv Sun Fire V125 Server Getting Started Guide September 2006 Introducing the Sun Fire V125 Server This Sun Fire V125 Server Getting Started Guide provides a basic hardware firmware and software introduction to the Sun Fire V125 server This guide also includes links to server resources instructions for planning installation of the server information about locating server cable connections server configuration information and preinstalled software information Server Overview The Sun Fire V125 server is a RoHS compliant UltraSPARC IIi based system that is rack mountable The server comes with the Solaris 10 Operating System OS the Java Enterprise System and the Advanced Lights Out Manager software preinstalled as a software image on the boot drive TABLE 1 summarizes some of the Sun Fire V125 server features TABLE1 Sun Fire V125 Server Features Sun Fire V125 Feature Height One rack unit CPU One 1 GHz UltraSPARC Mi Memory Two 512 megabyte DIMM Ethernet Two 10 100 1000BASE T ports ALOM One 10BASE T port Serial One port TABLE1 Sun Fire V125 Server Features
10. esources Sun Welcomes Your Comments Sun is interested in improving its documentation and welcomes your comments and suggestions You can submit your comments by going to http www sun com hwdocs feedback Please include the title and part number of your document with your feedback Sun Fire V125 Server Getting Started Guide part number 819 7423 10 12 Sun Fire V125 Server Getting Started Guide September 2006
11. intellectuels relatants la technologie qui est d crit dans ce document En particulier et sans la limitation ces droits de propri t intellectuels peuvent inclure un ou plus des brevets am ricains num r s http www sun com patents et un ou les brevets plus suppl mentaires ou les applications de brevet en attente dans les Etats Unis et dans les autres pays Ce produit ou document est prot g par un copyright et distribu avec des licences qui en restreignent l utilisation la copie la distribution et la d compilation Aucune partie de ce produit ou document ne peut tre reproduite sous aucune forme par quelque moyen que ce soit sans l autorisation pr alable et crite de Sun et de ses bailleurs de licence s il y en a Le logiciel d tenu par des tiers et qui comprend la technologie relative aux polices de caract res est prot g par un copyright et licenci par des fournisseurs de Sun Des parties de ce produit pourront tre d riv es des syst mes Berkeley BSD licenci s par l Universit de Californie UNIX est une marque d pos e aux Etats Unis et dans d autres pays et licenci e exclusivement par X Open Company Ltd Sun Sun Microsystems le logo Sun Sun Fire Java OpenBoot et Solaris sont des marques de fabrique ou des marques d pos es de Sun Microsystems Inc aux Etats Unis et dans d autres pays Toutes les marques SPARC sont utilis es sous licence et sont des marques de fabrique ou des marques d
12. ipation To calculate the heat generated by a server so that you can estimate the heat your cooling system must dissipate convert the figure for the system s power requirement from Watts to BTU hr A general formula for doing this is to multiply the power requirement figure in Watts by 3 412 Shipping Kit Contents The server is supplied with the components described in the following list m Rackmount kit m Cat5 RJ 45 cable m Accessories kit RJ 45 to DB 9 adapter RJ 45 to DB 25 adapter a Server documentation Note The contents of the shipping kit might vary depending on any options that you have ordered Make sure that all the basic parts as described in the list are present in the shipping kit If any component is missing contact your Sun sales representative Power Inlets and I O Ports Before you attach and route the cables become familiar with the location of the power inlets and I O ports on the back of the servers FIGURE 1 shows the back panel for the Sun Fire V125 server Introducing the Sun Fire V125 Server 7 Power inlet 10101 NET MGT SERIAL Ethernet 2 USB 2 LVD SCSI MGT FIGURE 1 Sun Fire V125 Server Back Panel Power The Sun Fire V125 server has a single AC inlet on the back of the server As long as the server is connected to a power source the server is in Standby power mode The only way to turn the server fully off is to remove the server from the power source by unplugging
13. ou must prepare the site This section includes information and links to information you will need to prepare the site Introducing the Sun Fire V125 Server 3 4 Physical Specifications TABLE 2 shows the physical specifications for the Sun Fire V125 server TABLE2 Physical Specifications Dimension Value Height 43 2 mm 1 7 in Width 425 mm 16 73 in Depth 635 mm 25 in Weight 12 3 kg unpackaged 27 1 lb Environmental Requirements You can operate and store the Sun Fire V125 system safely in the conditions detailed in TABLE 3 TABLE3 Operating and Storage Specifications Specification Operating Storage Ambient temperature 5 C 35 C maximum 40 C 65 C ambient temperature is derated by 2 C per 500 m altitude change above 500 m Relative humidity 10 90 RH noncondensing up to 93 RH nonconducting 27 C max wet bulb 38 C max wet bulb Altitude 400 m up to 3000 m 1312 ft 400 m up to 12000 m 1312 ft 9843 ft 39370 ft Recommended Operating Environment Your environmental control system must provide intake air for the server that complies with the limits specified in Environmental Requirements on page 4 To avoid overheating do not direct warmed air m Towards the front of the cabinet or rack a Towards the server access panels Sun Fire V125 Server Getting Started Guide September 2006 Note When you receive your system leave it in the environment
14. pos es de SPARC International Inc aux Etats Unis et dans d autres pays Les produits portant les marques SPARC sont bas s sur une architecture d velopp e par Sun Microsystems Inc L interface d utilisation graphique OPEN LOOK et Sun a t d velopp e par Sun Microsystems Inc pour ses utilisateurs et licenci s Sun reconna t les efforts de pionniers de Xerox pour la recherche et le d veloppement du concept des interfaces d utilisation visuelle ou graphique pour l industrie de l informatique Sun d tient une license non exclusive de Xerox sur l interface d utilisation grephique Xerox cette licence couvrant galement les licenci es de Sun qui mettent en place l interface d utilisation graphique OPEN LOOK et qui en outre se conforment aux licences crites de Sun LA DOCUMENTATION EST FOURNIE EN L TAT ET TOUTES AUTRES CONDITIONS DECLARATIONS ET GARANTIES EXPRESSES OU TACITES SONT FORMELLEMENT EXCLUES DANS LA MESURE AUTORISEE PAR LA LOI APPLICABLE Y COMPRIS NOTAMMENT TOUTE GARANTIE IMPLICITE RELATIVE A LA QUALITE MARCHANDE A L APTITUDE A UNE UTILISATION PARTICULIERE OU A L ABSENCE DE CONTREFA ON SA Ca Adobe PostScript Contents Server Overview 1 Server Installation Process 2 Site Preparation 3 Physical Specifications 4 Environmental Requirements 4 Recommended Operating Environment 4 Airflow Considerations 5 Acoustic Noise 6 Operating Power Limits and Ranges 6 Calculating Power Consumption 6 Calculating H
15. the power cable Ethernet Ports The Sun Fire V125 server has two autonegotiating 10 100 1000BASE T Ethernet system domain ports All the Ethernet ports use a standard RJ 45 connector the transfer rates for which are given in TABLE 6 TABLE6 Ethernet Connection Transfer Rates Connection Type IEEE Terminology Transfer Rate Ethernet 10BASE T 10 Mbit s Fast Ethernet 100BASE TX 100 Mbits s Gigabit Ethernet 1000BASE T 1000 Mbit s In addition each server has one 10BASE T Ethernet management domain interface labelled NET MGT For information on configuring this port for managing the server with ALOM see the Sun Advanced Lights Out Management ALOM 1 6 Administration Guide 8 Sun Fire V125 Server Getting Started Guide September 2006 Serial Ports The server has two serial ports labelled SERIAL MGT and 10101 The SERIAL MGT port accepts an RJ 45 connector Use this port only for server management The port labeled 10101 accepts a DB 9 connector Use this port for general purpose serial data transfer The default serial connection settings are listed in TABLE 7 TABLE7 Default Serial Connection Settings Parameter Setting Connector SERIAL MGT or 10101 Rate 9600 baud Parity None Stop bits 1 Data bits 8 If you need to connect to the SERIAL MGT port using either a DB 9 or a DB 25 connector use an adapter to perform the crossovers See the Sun System Handbook for more information about crossovers USB Ports
16. un Microsystems Inc in the U S and in other countries All SPARC trademarks are used under license and are trademarks or registered trademarks of SPARC International Inc in the U S and in other countries Products bearing SPARC trademarks are based upon an architecture developed by Sun Microsystems Inc The OPEN LOOK and Sun Graphical User Interface was developed by Sun Microsystems Inc for its users and licensees Sun acknowledges the pioneering efforts of Xerox in researching and developing the concept of visual or graphical user interfaces for the computer industry Sun holds a non exclusive license from Xerox to the Xerox Graphical User Interface which license also covers Sun s licensees who implement OPEN LOOK GUIs and otherwise comply with Sun s written license agreements U S Government Rights Commercial use Government users are subject to the Sun Microsystems Inc standard license agreement and applicable provisions of the FAR and its supplements DOCUMENTATION IS PROVIDED AS IS AND ALL EXPRESS OR IMPLIED CONDITIONS REPRESENTATIONS AND WARRANTIES INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE OR NON INFRINGEMENT ARE DISCLAIMED EXCEPT TO THE EXTENT THAT SUCH DISCLAIMERS ARE HELD TO BE LEGALLY INVALID Copyright 2006 Sun Microsystems Inc 4150 Network Circle Santa Clara Californie 95054 Etats Unis Tous droits r serv s Sun Microsystems Inc a les droits de propriete
Download Pdf Manuals
Related Search
Related Contents
00_Front Cover.fm Imprimer Samsung CE117AE-S User Manual TAxE D`APPRENTISSAgE 2014 DK-0917S Mode d`emploi b`ebike 7 english - Ktm parts SYLGARD® 309 取扱説明書 保存用 Copyright © All rights reserved.
Failed to retrieve file