Home

PCI UltraSCSI Host Adapter Installation Guide

image

Contents

1. 13 SD 6 36 SD 13 59 MSG 14 SD 7 37 SD 14 60 SEL 15 SDP 38 SP 15 61 C D 16 DIFFSENS 39 SDP 1 62 17 TERMPWR 40 GND 63 I O Appendix B Specifications Differential 21 22 TABLE B 6 SCSI Connector Pin Definitions Pin Description Pin Description Pin Description 18 TERMPWR 41 SD 0 64 GND 19 OPEN 42 SD 1 65 SD 8 20 ATN 43 SD 2 66 SD 9 21 GND 44 SD 3 67 SD 10 22 BSY 45 SD 4 68 SD 11 23 ACK 46 SD 5 PCI UltraSCSI Host Adapter Installation Guide June 1997 Ordering Sun Documents SunDocs is a distribution program for technical documentation and is available from SunExpress order or for more information Country Phone Fax Country Phone Fax Belgium 02 72 09 09 02 72 88 50 Luxembourg 32 2 72 09 09 32 2 725 88 50 Canada 1 80 873 7869 1 80 944 0661 Sweden 020 79 57 26 020 79 57 27 France 0800 90 61 57 080 90 61 58 Switzerland 0800 55 19 26 0800 55 19 27 Germany 01 30 81 61 31 01 30 81 61 92 United Kingdom 0800 89 88 88 0800 89 88 87 Holland 06 022 34 45 06 022 34 46 United States 1 800 873 7869 1 800 944 0661 Japan 0120 33 9096 0120 33 9097 World Wide Web nttp www sun com sunexpress Sun Welcomes Your Comments We are interested in improving our documentation and welcome your comments Use the reader comment card or send comments via email to smcc docs sun com You can also send a fax to SMCC Doc Feedback at 1 415 786 6443 Please include the part numbe
2. 8 Bus Length Differential Host Adapter The differential host adapter can support up to 15 devices per port on a SCSI bus length of 24 meters 78 74 feet Single Ended Host Adapter For UltraSCSI performance you must adhere to the following cable length restrictions m For 1 to 3 devices the maximum bus length per port is 3 meters 9 84 feet m For 4 to 7 devices the maximum bus length per port is 1 5 meters 4 92 feet If you exceed these bus length restrictions the UltraSCSI devices may operate at less than 40 Mbytes sec An UltraSCSI device on the bus may experience errors that eventually cause it to reset and operate at 20 Mbytes sec The following table shows bus length for each type of SCSI bus TABLE A 1 Bus Restrictions SCSI Type Bus Width Number of Devices SCSI Bus Length SCSI 2 Fast 8 bits 1 7 6 0 meters 19 7 feet SCSI 2 Fast Wide 16 bits 1 15 6 0 meters 19 7 feet UltraSCSI 16 bits 1 3 3 0 meters 9 84 feet 4 7 1 5 meters 4 92 feet 1 You must include the internal bus length of your system in your bus length calculations PCI UltraSCSI Host Adapter Installation Guide June 1997 Cabling and Termination Use the following cabling guidelines to ensure proper device cabling and termination m In order to maintain UltraSCSI performance all cables used must be UltraSCSI compliant m The SCSI bus must be correctly terminated Most Sun devices use autotermination See the documentation that c
3. Bottom 14 SCSI Connector Pin Definitions 15 Physical Dimensions 17 Power Requirements 18 Performance Specifications 18 PCI Edge Connector Pin Definitions J1B Top 19 PCI Edge Connector Pin Definitions J1A Bottom 20 SCSI Connector Pin Definitions 21 Tables xv xvi PCI UltraSCSI Host Adapter Installation Guide June 1997 Preface The PCI UltraSCSI Host Adapter Installation Guide provides information about PCI single ended and differential dual channel UltraSCSI host adapter cards Using UNIX Commands This document does not contain information on basic UNIX commands and procedures such as shutting down the system booting the system and configuring devices See one or more of the following for this information m Solaris 2 x Handbook for SMCC Peripherals m AnswerBook online documentation for the Solaris 2 x software environment m Other software documentation that you received with your system Preface xvii Typographic Conventions TABLEP 1 Typographic Conventions Typeface or Symbol Meaning AaBbCc123 The names of commands files and directories on screen computer output AaBbCc123 What you type when contrasted with on screen computer output AaBbCc123 Book titles new words or terms words to be emphasized Command line variable replace with a real name or value Examples Edit your login file Use 1s a to list all files e You have mail oe u Password
4. Capacitance per PCI signal line SCSI interface SCSI bus parity SCSI 8 bit bus devices SCSI 16 bit bus devices PCI UltraSCSI Host Adapter Installation Guide June 1997 Specification 33 MHz maximum 132 Mbytes sec burst rate 40 Mbytes sec wide lt 7 Mtransfers sec cable dependent 4 GByte maximum AD31 0 Master slave lt 10 except for CLK between 5 to 12 pF and IDSEL lt 8pF Wide differential Yes Yes Yes PCI Edge Connector Pin Definitions TABLE B 4 PCI Edge Connector Pin Definitions J1B Top Pin Description Pin Description Pin Description 1 12V 22 GND 43 3 3V 2 TCK 23 AD27 44 C_BE1 3 GND 24 AD25 45 AD14 4 TDO 25 3 3V 46 GND 5 5V 26 C_BE3 47 AD12 6 5V 27 AD23 48 AD10 7 INTB 28 GND 49 GND 8 INTD 29 AD21 50 KEYWAY 9 GND PRSNT1 30 AD19 51 KEYWAY 10 RESERVED 31 3 3V 52 ADO08 11 GND PRSNT2 32 ART 53 ADO7 12 KEYWAY 33 C_BE2 54 3 3V 13 KEYWAY 34 GND 55 ADO5 14 RESERVED 35 IRDY 56 ADO3 15 GND 36 3 3V 57 GND 16 CLK 37 DEVSEL 58 17 GND 38 GND 59 3V 5V 18 REQ 39 LOCK 60 ACK64 19 3V 5V 40 PERR 61 5V 20 AD31 41 3 3V 62 5V 21 AD29 42 SERR Appendix B Specifications Differential 19 TABLEB 5 PCI Edge Connector Pin Definitions JIA Bottom Pin Description 1 TRST 2 12V 3 TMS 4 TDI 5 5V 6 INTA 7 INTC 8 5V 9 RESERVED 10 3V 5V 11 RESERVED 12 KEYWAY 13 KEYWAY 14 RESERVED 15 RST 16 3V 5V 17 GNT 18 GND 19 RESERVED
5. 20 AD30 21 3 3V Pin 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 Description AD28 AD26 GND AD24 IDSEL 3 3V AD22 AD20 GND AD18 AD16 3 3V FRAME GND TRDY GND STOP 3 3V SDONE SBO GND Pin 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 Description PAR AD15 3 3V AD13 AD11 GND ADO9 KEYVVAY KEYVVAY C_BEO 3 3V AD06 AD04 GND ADO2 3V 5V REQ64 5V 5V 20 PCI UltraSCSI Host Adapter Installation Guide June 1997 SCSI Connector Pin Definitions 34 1 O O 68 35 VHDCI Connector 34 1 68 35 Internal SCSI Connector FIGURE B 1 VHDCI and Internal SCSI Connectors TABLE B 6 SCSI Connector Pin Definitions Pin Description Pin Description Pin Description 1 SD 12 24 RST 47 SD 6 2 SD 13 25 MSG 48 SD 7 3 SD 14 26 SEL 49 SDP 4 SD 15 27 C D 50 Cable Sense GND 5 SDP 1 28 REQ 51 TERMPWR 6 GND 29 1 0 52 TERMPWR 7 SD 0 30 GND 53 OPEN 8 SD 1 31 SD 8 54 ATN 9 SD 2 32 SD 9 55 GND 10 SD 3 33 SD 10 56 BSY 11 SD 4 34 SD 11 57 ACK 12 SD 5 35 SD 12 58 RST
6. Read Chapter 6 in the User s Guide These are called class options You must be root to do this To delete a file type rm filename Shell Prompts TABLE P 2 Shell Prompts Shell C shell C shell superuser Bourne shell and Korn shell Bourne shell and Korn shell superuser PCI UltraSCSI Host Adapter Installation Guide June 1997 Prompt machine_name machine names Ordering Sun Documents SunDocs is a distribution program for Sun Microsystems technical documentation Contact SunExpress for easy ordering and quick delivery You can find a listing of available Sun documentation on the World Wide Web TABLE P 3 SunExpress Contact Information Country Telephone Fax Belgium 02 720 09 09 02 725 88 50 Canada 1 800 873 7869 1 800 944 0661 France 0800 90 61 57 0800 90 61 58 Germany 01 30 81 61 91 01 30 81 61 92 Holland 06 022 34 45 06 022 34 46 Japan 0120 33 9096 0120 33 9097 Luxembourg 32 2 720 09 09 32 2 725 88 50 Sweden 020 79 57 26 020 79 57 27 Switzerland 0800 55 19 26 0800 55 19 27 United Kingdom United States 0800 89 88 88 1 800 873 7869 0800 89 88 87 1 800 944 0661 World Wide Web http www sun com sunexpress Sun Welcomes Your Comments Please use the Reader Comment Card that accompanies this document We are interested in improving our documentation and welcome your comments and suggestions If a card is not available you can email or fax your comments to us Please inc
7. de seguridad El siguiente texto incluye las medidas de seguridad que se deben seguir cuando se instale alg n producto de Sun Microsystems Precauciones de seguridad Para su protecci n observe las siguientes medidas de seguridad cuando manipule su equipo Siga todas los avisos e instrucciones marcados en el equipo Aseg rese de que el voltaje y la frecuencia de la red el ctrica concuerdan con las descritas en las etiquetas de especificaciones el ctricas del equipo viii PCI UltraSCSI Host Adapter Installation Guide June 1997 No introduzca nunca objetos de ning n tipo a trav s de los orificios del equipo Pueden haber voltajes peligrosos Los objetos extrafios conductores de la electricidad pueden producir cortocircuitos que provoquen un incendio descargas el ctricas o da os en el equipo S mbolos En este libro aparecen los siguientes s mbolos Precauci n Existe el riesgo de lesiones personales y da os al equipo Siga las instrucciones Precauci n Superficie caliente Evite el contacto Las superficies est n calientes y pueden causar da os personales si se tocan el riesgo de descarga y da os para la salud siga las Precauci n Voltaje peligroso presente Para reducir instrucciones Encendido Aplica la alimentaci n de CA al sistema Seg n el tipo de interruptor de encendido que su equipo tenga es posible que se utilice uno de los siguientes s mbolo
8. que ce soit sans l autorisation pr alable et crite de Sun et de ses bailleurs de licence s il y en a Des parties de ce produit pourront tre deriv es du syst me UNIX licenci par Novell Inc et du syst me Berkeley 4 3 BSD licenci par l Universit de Californie UNIX est une marque enregistr e aux Etats Unis et dans d autres pays et licenci e exclusivement par X Open Company Ltd Le logiciel d tenu par des tiers et qui comprend la technologie relative aux polices de caract res est prot g par un copyright et licenci par des fournisseurs de Sun Sun Sun Microsystems le logo Sun SunOS et Solaris sont des marques d pos es ou enregistr es de Sun Microsystems Inc aux Etats Unis et dans d autres pays Toutes les marques SPARC utilis es sous licence sont des marques d pos es ou enregistr es de SPARC International Inc aux Etats Unis et dans d autres pays Les produits portant les marques SPARC sont bas s sur une architecture d velopp e par Sun Microsystems Inc Les utilisateurs d interfaces graphiques OPEN LOOK et Sun ont t d velopp s de Sun Microsystems Inc pour ses utilisateurs et licencies Sun reconnait les efforts de pionniers de Xerox Corporation pour la recherche et le d veloppement du concept des interfaces d utilisation visuelle ou graphique pour l industrie de l informatique Sun d tient une licence non exclusive de Xerox sur l interface d utilisation graphique cette licence couvrant aussi les
9. s curit qu il convient de prendre pour l installation d un produit Sun Microsystems Mesures de s curit Pour votre protection veuillez prendre les pr cautions suivantes pendant l installation du mat riel Suivre tous les avertissements et toutes les instructions inscrites sur le mat riel V rifier que la tension et la fr quence de la source d alimentation lectrique correspondent la tension et la fr quence indiqu es sur l tiquette de classification de l appareil Ne jamais introduire d objets quels qu ils soient dans une des ouvertures de l appareil Vous pourriez vous trouver en pr sence de hautes tensions dangereuses Tout objet conducteur introduit de la sorte pourrait produire un court circuit qui entrainerait des flammes des risques d lectrocution ou des deg ts mat riels Symboles Vous trouverez ci dessous la signification des diff rents symboles utilis s Attention risques de blessures corporelles et de deg ts mat riels Veuillez suivre les instructions Attention surface temp rature lev e Evitez le contact La temp rature des surfaces est lev e et leur contact peut provoquer des blessures corporelles Attention pr sence de tensions dangereuses Pour viter les risques d lectrocution et de danger pour la sant physique veuillez suivre les instructions MARCHE Votre syst me est sous tension courant alternatif Un des symbole
10. the etc release file and make sure the operating system installed is at least Solaris 2 5 1 Hardware 4 97 Note You must upgrade your operating system to at least Solaris 2 5 1 Hardware 4 97 if you do not have an etc release file Exit the operating system If your system is a server use the shut down command to inform the mounted users that the system will be going down Otherwise use the init 0 command See the man pages for these commands or the Solaris AnswerBook online documentation Power down the system Refer to the service documentation that came with your system Caution Do not disconnect the power cord from the system or from the wall outlet This connection provides the ground path necessary to safely remove and install the printed circuit boards and components without damaging them Choose a slot into which you will install the host adapter Follow the procedures in the documentation supplied with your system Unpack the host adapter You should have the following items m PCI UltraSCSI host adapter FIGURE 1 1 2 meter UltraSCSI compliant cable a Electrostatic discharge ESD kit Note Leave the host adapter in the protective bag until you are ready to install it PCI UltraSCSI Host Adapter Installation Guide June 1997 PCI connector Internal SCSI connector 2 VHDCI connector 2 VHDCI connector 1 Internal SCSI connector 1 FIGURE 1 1 PCI UltraSCSI Host Adap
11. Canada DOC Class B Notice Avis DOC Classe B This Class B digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations Cet appareil num rique de la classe B respecte toutes les exigences du Reglement sur le mat riel brouilleur du Canada VCCI iv HELIO LT EA VCCIE amp EICIIT B MVCCDRRMNSEATI YIA T UVYISYBLUFTT a BER RECT N6D0fmici PR OJHHAZNE CHUS DREUX BARRE R LERB OTER AND N IN ES MEDEE HM EL KERNE EA A EB e VOCI AES C MAUTEVEF LEMOT ARA MBR E IHR ER LIHET CHJHNCAUSe 377 TUE A ZARA BEF 2 TCEMBOVET HO ROBAN NES TEL lt BROMUS ESV EZEVOCHEIIUNT S REVCCI DER NA T IAT lt 737DBXKUA 7737 MI E RE TI TCHSOMM Cl FORMAS LUET Et AAA ERE ZEZE kie HZ U 7 Histic 35 v CHE AN FREE CEE CO ERRE LE Ze 8 UAEM E HIDE VCC ES LAL AE 274 S RIE TEAK Eq ZEMEOHNLIZZIENBUET WO RV AIC HES TEL lt 33800 SR lt EAN PCI UltraSCSI Host Adapter Installation Guide June 1997 Safety Agency Compliance Statements Read this section before beginning any procedure The following text provides safety precautions to follow when installing a Sun Microsystems product Safety Precautions For your protection observe the following safety precautions when setting up your equipment Follow all cautions and instructions marked on the equipment Ensure that the voltage and freq
12. GND 32 GND 55 ATN 10 GND 33 GND 56 GND 11 GND 34 Cable Sense GND 57 BSY 12 GND 35 SD 12 58 ACK 13 GND 36 SD 13 59 RST 14 GND 37 SD 14 60 MSG 15 GND 38 SP 15 61 SEL 16 GND 39 SDP 1 62 C D Appendix B Specifications Single Ended TABLE B 6 SCSI Connector Pin Definitions Continued Pin Description Pin Description Pin Description 17 TERMPWR 40 SD 0 63 REQ 18 TERMPWR 41 SD 1 64 I O 19 OPEN 42 SD 2 65 SD 8 20 GND 43 SD 3 66 SD 9 21 GND 44 SD 4 67 SD 10 22 GND 45 SD 5 68 SD 11 23 GND 46 SD 6 16 PCI UltraSCSI Host Adapter Installation Guide June 1997 APPENDIX B Specifications Differential The chapter contains the specifications for the wide differential host adapter Physical Dimensions TABLE B 1 Physical Dimensions Dimension Measurement Board With Bracket Board Without Bracket Length 8 inches 203 2 mm 7 5 inches 190 5 mm Width 4 81 inches 122 17 mm 3 8 inches 96 5 mm Height 85 inches 21 59 mm 5 inches 12 7 mm Weight 5 2 oz 43 42 g N A 17 Power Requirements TABLEB 2 Power Requirements Voltage Maximum Current 5V 15 3A 3 3V 19 130 ma 12V 15 0 05A 18 Performance Specifications TABLE B 3 Performance Specifications Feature PCI clock PCI data burst transfer rate SCSI synchronous transfer rate SCSI asynchronous transfer rate Transfer block size PCI data address lines PCI modes
13. PCI UltraSCSI Host Adapter Installation Guide Single Ended and Differential Dual Channel Models AS THE NETWORK IS THE COMPUTER Sun Microsystems Computer Company A Sun Microsystems Inc Business 2550 Garcia Avenue Mountain View CA 94043 USA 415 960 1300 fax 415 969 9131 Part No 805 1271 10 Revision A June 1997 Copyright 1997 Sun Microsystems Inc 2550 Garcia Avenue Mountain View California 94043 1100 U S A Allrights reserved This product or document is protected by copyright and distributed under licenses restricting its use copying distribution and decompilation No part of this product or document may be reproduced in any form by any means without prior written authorization of Sun and its licensors if any Portions of this product may be derived from the UNIX system licensed from Novell Inc and from the Berkeley 4 3 BSD system licensed from the University of California UNIX is a registered trademark in the United States and in other countries and is exclusively licensed by X Open Company Ltd Third party software including font technology in this product is protected by copyright and licensed from Sun s suppliers RESTRICTED RIGHTS Use duplication or disclosure by the U S Government is subject to restrictions of FAR 52 227 14 g 2 6 87 and FAR 52 227 19 6 87 or DFAR 252 227 7015 b 6 95 and DFAR 227 7202 3 a Sun Sun Microsystems the Sun logo SunOS and Solaris are trademarks or registere
14. ame with the device m If external mass storage devices consist of 68 pin devices and 50 pin devices connect the 68 pin devices to the system first and terminate the chain with a 50 pin device and its terminator The 68 pin device connected to 68 50 pin adapter cable must be auto terminating in order to terminate the high order bits Caution Do not connect 68 pin devices after 50 pin devices SCSI bus errors will occur The following figure provides a summary of the cabling guidelines Autoterminating System Sun device Sun device cun device 68 68 68 68 68 68 Autoterminating System Sun device Sun device 50 pin device E C Jr E A 68 68 68 68 G n Samar Adapter cable FIGURE A 1 Cabling Guidelines Appendix A Understanding UltraSCSI 9 10 PCI UltraSCSI Host Adapter Installation Guide June 1997 APPENDIX B Specifications Single Ended The chapter contains the specifications for the single ended host adapter Physical Dimensions TABLE B 1 Physical Dimensions Dimension Measurement Board With Bracket Board Without Bracket Length 8 inches 203 2 mm 7 5 inches 190 5 mm Width 4 81 inches 122 17 mm 3 8 inches 96 5 mm Height 85 inches 21 59 mm 5 inches 12 7 mm Weight 5 7 oz 47 59 g N A 11 Power Requirements TABLEB 2 Power Requirements Voltage Maximum Current 5V 15 3A 3 3V 39 130 mA 12V 15 0 05A 12 P
15. d trademarks of Sun Microsystems Inc in the United States and in other countries AllSPARC trademarks are used under license and are trademarks or registered trademarks of SPARC International Inc in the United States and in other countries Products bearing SPARC trademarks are based upon an architecture developed by Sun Microsystems Inc The OPEN LOOK and Sun Graphical User Interfaces were developed by Sun Microsystems Inc for its users and licensees Sun acknowledges the pioneering efforts of Xerox Corporation in researching and developing the concept of visual or graphical user interfaces for the computer industry Sun holds a nonexclusive license from Xerox to the Xerox Graphical User Interface which license also covers Sun s licensees who implement OPEN LOOK GUIs and otherwise comply with Sun s written license agreements THIS PUBLICATION IS PROVIDED AS IS WITHOUT WARRANTY OF ANY KIND EITHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE OR NON INFRINGEMENT Copyright 1997 Sun Microsystems Inc 2550 Garcia Avenue Mountain View Californie 94043 1100 U S A Tous droits r serv s Ce produit ou document est prot g par un copyright et distribu avec des licences qui en restreignent l utilisation la copie et la d compilation Aucune partie de ce produit ou de sa documentation associ e ne peut tre reproduite sous aucune forme par quelque moyen
16. efinitions JIA Bottom Pin Description 1 TRST 2 12V 3 TMS 4 TDI 5 5V 6 INTA 7 INTC 8 5V 9 RESERVED 10 3V 5V 11 RESERVED 12 KEYWAY 13 KEYWAY 14 RESERVED 15 RST 16 3V 5V 17 GNT 18 GND 19 RESERVED 20 AD30 21 3 3V Pin 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 Description AD28 AD26 GND AD24 IDSEL 3 3V AD22 AD20 GND AD18 AD16 3 3V FRAME GND TRDY GND STOP 3 3V SDONE SBO GND Pin 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 Description PAR AD15 3 3V AD13 AD11 GND ADO9 KEYVVAY KEYVVAY C_BEO 3 3V AD06 AD04 GND ADO2 3V 5V REQ64 5V 5V 14 PCI UltraSCSI Host Adapter Installation Guide June 1997 SCSI Connector Pin Definitions 34 1 CERI 68 VHDCI Connector a 34 1 E T Internal SCSI Connector FIGURE B 1 VHDCI and Internal SCSI Connectors TABLE B 6 SCSI Connector Pin Definitions Pin Description Pin Description Pin Description 1 GND 24 GND 47 SD 7 2 GND 25 GND 48 SDP 3 GND 26 GND 49 GND 4 GND 27 GND 50 Cable Sense GND 5 GND 28 GND 51 TERMPWR 6 GND 29 GND 52 TERMPWR 7 GND 30 GND 53 OPEN 8 GND 31 GND 54 GND 9
17. en die Daten zur Stromversorgung in Ihrem Geb ude geben Achtung Nicht alle Netzkabel haben die gleichen Nennwerte Herk mmliche im Haushalt verwendete Verl ngerungskabel besitzen keinen berlastungsschutz und sind daher f r Computersysteme nicht geeignet Achtung Ihr Sun Ger t wird mit einem dreiadrigen Netzkabel f r geerdete Netzsteckdosen geliefert Um die Gefahr eines Stromschlags zu reduzieren schlie en Sie das Kabel nur an eine fachgerecht verlegte geerdete Steckdose an Die folgende Warnung gilt nur f r Ger te mit Wartezustand Netzschalter Achtung Der Ein Aus Schalter dieses Ger ts schaltet nur auf Wartezustand Stand By Modus Um die Stromzufuhr zum Ger t vollst ndig zu unterbrechen m ssen Sie das Netzkabel von der Steckdose abziehen Schlie en Sie den Stecker des Netzkabels an eine in der N he befindliche frei zug ngliche geerdete Netzsteckdose an Schlie en Sie das Netzkabel nicht an wenn das Netzteil aus der Systemeinheit entfernt wurde Geh useabdeckung Sie m ssen die obere Abdeckung Ihres Sun Systems entfernen um interne Komponenten wie Karten Speicherchips oder Massenspeicher hinzuzuf gen Bringen Sie die obere Geh useabdeckung wieder an bevor Sie Ihr System einschalten Achtung Bei Betrieb des Systems ohne obere Abdeckung besteht die Gefahr von Stromschlag und Systemsch den Conformit aux normes de s curit Ce texte traite des mesures de
18. erformance Specifications TABLE B 3 Performance Specifications Feature PCI clock PCI data burst transfer rate SCSI synchronous transfer rate SCSI asynchronous transfer rate Transfer block size PCI data address lines PCI modes Capacitance per PCI signal line SCSI interface SCSI bus parity SCSI 8 bit bus devices SCSI 16 bit bus devices PCI UltraSCSI Host Adapter Installation Guide June 1997 Specification 33 MHz maximum 132 Mbyte sec 20 40 Mbytes sec Narrow Wide 5 Mtransfers sec cable dependent 4 Gbyte maximum AD31 0 Master slave lt 10 except for CLK between 5 to 12 pF and IDSEL lt 8 pF Single ended Yes Yes Yes PCI Edge Connector Pin Definitions TABLE B 4 PCI Edge Connector Pin Definitions J1B Top Pin Description Pin Description Pin Description 1 12V 22 GND 43 3 3V 2 TCK 23 AD27 44 C 3 GND 24 AD25 45 AD14 4 TDO 25 3 3V 46 GND 5 5V 26 C_BE3 47 AD12 6 5V 27 AD23 48 AD10 7 INTB 28 GND 49 GND 8 INTD 29 AD21 50 KEYWAY 9 GND PRSNTI 30 AD19 51 KEYWAY 10 RESERVED 31 3 3V 52 ADO08 11 GND PRSNT2 32 AD17 53 ADO7 12 KEYVVAY 33 C_BE2 54 3 3V 13 KEYWAY 34 GND 55 ADO5 14 RESERVED 35 IRDY 56 ADO3 15 GND 36 3 3V 57 GND 16 CLK 37 DEVSEL 58 ADO1 17 GND 38 GND 59 3V 5V 18 REQ 39 LOCK 60 ACK64 19 3V 5V 40 PERR 61 5V 20 AD31 41 3 3V 62 5V 21 AD29 42 SERR Appendix B Specifications Single Ended 13 TABLEB 5 PCI Edge Connector Pin D
19. figuration of your host adapter card Run the SunVTS program before attempting to use your new card for applications This section provides a brief set of instructions for running the SunVTS program For more details refer to the SunVTS 2 X User s Guide Become superuser su lt Return gt password Bring up the SunVTS window opt SUNWvts bin sunvts Select a disk drive that is attached to the host adapter card you just installed Start the test Verify that no errors have occurred by checking the SunVTS status window If no problems occur stop SunVTS Your host adapter card is ready to run applications Chapter 1 Installing the Host Adapter 5 6 PCIUltraSCSI Host Adapter Installation Guide June 1997 APPENDIX A Understanding UltraSCSI This chapter provides general information about UltraSCSI configuration rules Target Devices For UltraSCSI performance of 40 Mbytes sec there can be a maximum of seven devices connected to each port on the host adapter card Up to 15 devices can be connected to each port on the host adapter card at 20 Mbytes sec Note If a bus is too busy to support 40 Mbytes sec an UltraSCSI device may experience errors that eventually cause it to reset and operate at 20 Mbytes sec The available target addresses SCSI IDs for each port on the host adapter cards are 0 through F Note The SCSI ID of 7 is reserved for the host adapter card
20. forc ment la m me puissance nominale en mati re de courant Les rallonges d usage domestique n offrent pas de protection contre les surcharges et ne sont pas pr vues pour les syst mes d ordinateurs Ne pas utiliser de rallonge d usage domestique avec votre produit Sun Attention votre produit Sun a t livr quip d un cordon d alimentation trois fils avec prise de terre Pour carter tout risque d lectrocution branchez toujours ce cordon dans une prise mise la terre L avertissement suivant s applique uniquement aux systemes quip s d un interrupteur VEILLEUSE produit fonctionne comme un dispositif de mise en veille uniquement C est la prise d alimentation qui sert mettre le produit hors tension Veillez donc installer le produit proximit d une prise murale facilement accessible Ne connectez pas la prise d alimentation lorsque le ch ssis du syst me n est plus aliment Attention le commutateur d alimentation de ce Couvercle Pour ajouter des cartes de la m moire ou des unit s de stockage internes vous devrez d monter le couvercle de l unit syst me Sun Ne pas oublier de remettre ce couvercle en place avant de mettre le syst me sous tension Attention il est dangereux de faire fonctionner un produit Sun sans le couvercle en place Si l on n glige cette pr caution on encourt des risques de blessures corporelles et de d g ts mat riels Normativas
21. g and screws to secure the card Caution Using excessive force can bend or damage the pins 8 Remove the wrist strap 9 Close the system 10 Connect the SCSI cables Refer to your system documentation for cabling instructions 11 If you have disconnected the power cable reconnect it 12 Power on your peripherals and then your system Note If your system starts to reboot interrupt the reboot process by pressing the Stop and A keys together 13 Make sure the host adapter is recognized by the system Use the probe scsi all command to display the SCSI devices connected to your system For example ok probe scsi all pcei 1f 2000 scsi 2 Target 8 Unit 0 Disk SEAGATE ST34371W SUN4 2G8254 pci 1f 2000 scsi 2 1 Target 1 Unit 0 Disk SEAGATE ST34371W SUN4 2G8254 In the example the first SCSI port scsi 2 has one disk drive connected target 8 The second SCSI port scsi 2 1 also has one disk drive connected target 1 In FIGURE 1 1 the first SCSI ports are labeled as 1 the second SCSI ports are 2 4 PCI UltraSCSI Host Adapter Installation Guide June 1997 14 Reboot your system using the boot r command For more information on the boot r command refer to the System Administrator s Guide for your operating system To Test the Installation With SunVTS SunVTS is a diagnostic program that exercises your system to verify the functionality reliability and con
22. ge und Verletzungen zu vermeiden Achtung Gef hrliche Spannungen Anweisungen Ein Setzt das System unter Wechselstrom vi PCI UltraSCSI Host Adapter Installation Guide June 1997 Je nach Netzschaltertyp an Ihrem Ger t kann eines der folgenden Symbole benutzt werden Aus Unterbricht die Wechselstromzufuhr zum Ger t Wartezustand Stand by Position Der Ein Wartezustand Schalter steht auf Wartezustand nderungen an Sun Ger ten Nehmen Sie keine mechanischen oder elektrischen nderungen an den Ger ten vor Sun Microsystems bernimmt bei einem Sun Produkt das ge ndert wurde keine Verantwortung f r die Einhaltung beh rdlicher Vorschriften Aufstellung von Sun Ger ten Achtung Um den zuverl ssigen Betrieb Ihres Sun Ger ts zu gew hrleisten und es vor berhitzung zu sch tzen d rfen die ffnungen im Ger t nicht blockiert oder verdeckt werden Sun Produkte sollten niemals in der N he von Heizk rpern oder Heizluftklappen aufgestellt werden Einhaltung der SELV Richtlinien Die Sicherung der I O Verbindungen entspricht den Anforderungen der SELV Spezifikation Anschlu des Netzkabels Achtung Sun Produkte sind f r den Betrieb an i Einphasen Stromnetzen mit geerdetem Nulleiter vorgesehen Um die Stromschlaggefahr zu reduzieren schlie en Sie Sun Produkte nicht an andere Stromquellen an Ihr Betriebsleiter oder ein qualifizierter Elektriker kann Ihn
23. in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna e Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected e Consult the dealer or an experienced radio television technician for help Shielded Cables Connections between the workstation and peripherals must be made using shielded cables in order to maintain compliance with FCC radio frequency emission limits Networking connections can be made using unshielded twisted pair UTP cables Modifications Any modifications made to this device that are not approved by Sun Microsystems Inc may void the authority granted to the user by the FCC to operate this equipment Regulatory Compliance Statements iii DOC Class A Notice Avis DOC Classe A This Class A digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations Cet appareil numerique de la classe A respecte toutes les exigences du Reglement sur le materiel brouilleur du
24. licenci s de Sun qui mettent en place les utilisateurs d interfaces graphiques OPEN LOOK et qui en outre se conforment aux licences crites de Sun CETTE PUBLICATION EST FOURNIE EN L ETAT SANS GARANTIE D AUCUNE SORTE NI EXPRESSE NI IMPLICITE Y COMPRIS ET SANS QUE CETTE LISTE NE SOIT LIMITATIVE DES GARANTIES CONCERNANT LA VALEUR MARCHANDE L APTITUDE DES PRODUITS A REPONDRE A UNE UTILISATION PARTICULIERE OU LE FAIT QU ILS NE SOIENT PAS CONTREFAISANTS DE PRODUITS DE TIERS moe KA Adobe PostScript Regulatory Compliance Statements Your Sun product is marked to indicate its compliance class e Federal Communications Commission FCC USA Department of Communications DOC Canada e Voluntary Control Council for Interference VCCI Japan Please read the appropriate section that corresponds to the marking on your Sun product before attempting to install the product FCC Class A Notice This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference 2 This device must accept any interference received including interference that may cause undesired operation Note This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial envir
25. lude the part number of your document in the subject line of your email or fax message m Email sncc docs sun com m Fax SMCC Document Feedback 1 415 786 6443 xix xx PCI UltraSCSI Host Adapter Installation Guide June 1997 CHAPTER 1 Installing the Host Adapter This chapter describes the PCI single ended and differential dual channel UltraSCSI host adapter cards and explains how to install them into your system Before you begin have your system documentation available for reference You will need to perform system administration procedures to halt and boot your system Note If you are unfamiliar with UltraSCSI configuration guidelines read Appendix A Understanding UltraSCSI before performing the procedures in this chapter Overview The single ended and differential host adapters are UltraSCSI devices that enable you to increase the available number of SCSI ports for adding external devices The host adapters are designed to be installed in SPARC systems running at least Solaris 2 5 1 Hardware 4 97 operating system The host adapters support up to 15 targets on each SCSI bus For details see Appendix A Understanding UltraSCSI 2 Installing the Host Adapter Read these instructions and the installation instructions in your system documentation before installing the host adapter To Prepare for Installation Determine which version of the operating system you are running Look at
26. oduct SELV Compliance Safety status of I O connections comply to SELV requirements Power Cord Connection single phase power systems having a grounded neutral conductor To reduce the risk of electric shock do not plug Sun products into any other type of power system Contact your facilities manager or a qualified electrician if you are not sure what type of power is supplied to your building Caution Sun products are designed to work with Caution Not all power cords have the same current ratings Household extension cords do not have overload protection and are not meant for use with computer systems Do not use household extension cords with your Sun product grounding type three wire power cord To reduce the risk of electric shock always plug the cord into a grounded power outlet Caution Your Sun product is shipped with a The following caution applies only to devices with a Standby power switch Caution The power switch of this product functions as a standby type device only The power cord serves as the primary disconnect device for the system Be sure to plug the power cord into a grounded power outlet that is nearby the system and is readily accessible Do not connect the power cord when the power supply has been removed from the system chassis System Unit Cover You must remove the cover of your Sun computer system unit in order to add cards memory or internal sto
27. onment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Shielded Cables Connections between the workstation and peripherals must be made using shielded cables in order to maintain compliance with FCC radio frequency emission limits Networking connections can be made using unshielded twisted pair UTP cables Modifications Any modifications made to this device that are not approved by Sun Microsystems Inc may void the authority granted to the user by the FCC to operate this equipment FCC Class B Notice This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference 2 This device must accept any interference received including interference that may cause undesired operation Note This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used
28. por tanto no son apropiados para su uso con computadores No utilice alargadores de tipo dom stico para conectar sus productos Sun Precauci n No todos los cables de alimentaci n cable de alimentaci n con toma de tierra Para reducir el riesgo de descargas el ctricas con ctelo siempre a un enchufe con toma de tierra Precauci n Con el producto Sun se proporciona un La siguiente advertencia se aplica solamente a equipos con un interruptor de encendido que tenga una posici n En espera producto funciona exclusivamente como un dispositivo de puesta en espera El enchufe de la fuente de alimentaci n est dise ado para ser el elemento primario de desconexi n del equipo El equipo debe instalarse cerca del enchufe de forma que este ltimo pueda ser f cil y r pidamente accesible No conecte el cable de alimentaci n cuando se ha retirado la fuente de alimentaci n del chasis del sistema Precauci n El interruptor de encendido de este Tapa de la unidad del sistema Debe quitar la tapa del sistema cuando sea necesario a adir tarjetas memoria o dispositivos de almacenamiento internos Aseg rese de cerrar la tapa superior antes de volver a encender el equipo productos Sun sin la tapa superior colocada El hecho de no tener en cuenta esta precauci n puede ocasionar da os personales o perjudicar el funcionamiento del equipo Precauci n Es peligroso hacer funcionar los Safet
29. r of your document in the subject line of your email or fax message Reader Comment Card For the PCI UltraSCSI Host Adapter Installation Guide part number 805 1271 10 1 Were the procedures documented thoroughly 2 Were the illustrations helpful 3 Was the information accurate and easy to follow 4 Did you refer to this manual online 5 Additional comments s Z Z d 9 E O E o gt E O Address 5 o 8 gt g 5 S 8 n E 9 U p 28g lt 2 IR gt a 2 B ow UNE P AIR MAIL PAR AVION NE PAS AFFRANCHIR IBRS CCRI No 808 NECESSARY IF MAILED TO THE UNITED STATES INTERNATIONAL REPLY MAIL RESPONSE MOUNTAIN VIEW CA en WILL BE PAID BY ADDRESSEE INFORMATION PRODUCTS M S MPK14 108 SUN MICROSYSTEMS INC 2550 GARCIA AVE MOUNTAIN VIEW CA 94043 9551 UNITED STATES OF AMERICA
30. rage devices Be sure to replace the top cover before powering up your computer system Safety Agency Compliance Statements v Caution Do not operate Sun products without the top cover in place Failure to take this precaution may result in personal injury and system damage Einhaltung sicherheitsbeh rdlicher Vorschriften Auf dieser Seite werden Sicherheitsrichtlinien beschrieben die bei der Installation von Sun Produkten zu beachten sind Sicherheitsvorkehrungen Treffen Sie zu Ihrem eigenen Schutz die folgenden Sicherheitsvorkehrungen wenn Sie Ihr Ger t installieren Beachten Sie alle auf den Ger ten angebrachten Warnhinweise und Anweisungen Vergewissern Sie sich da Spannung und Frequenz Ihrer Stromquelle mit der Spannung und Frequenz bereinstimmen die auf dem Etikett mit den elektrischen Nennwerten des Ger ts angegeben sind Stecken Sie auf keinen Fall irgendwelche Gegenst nde in ffnungen in den Ger ten Leitf hige Gegenst nde k nnten aufgrund der m glicherweise vorliegenden gef hrlichen Spannungen einen Kurzschlu verursachen der einen Brand Stromschlag oder Ger teschaden herbeif hren kann Symbole Die Symbole in diesem Handbuch haben folgende Bedeutung Achtung Gefahr von Verletzung und Ger teschaden Befolgen Sie die Anweisungen Achtung Hohe Temperatur Nicht ber hren da Verletzungsgefahr durch hei e Oberfl che besteht befolgen um Stromschl
31. s Apagado Elimina la alimentaci n de CA del sistema En espera El interruptor de Encendido En espera C se ha colocado en la posici n de En espera Modificaciones en el equipo No realice modificaciones de tipo mec nico o el ctrico en el equipo Sun Microsystems no se hace responsable del cumplimiento de las normativas de seguridad en los equipos Sun modificados Ubicaci n de un producto Sun funcionamiento de su producto Sun y para protegerlo de sobrecalentamien tos no deben obstruirse o taparse las rejillas del equipo Los productos Sun nunca deben situarse cerca de radiadores o de fuentes de calor N Precauci n Para asegurar la fiabilidad de Cumplimiento de la normativa SELV El estado de la seguridad de las conexiones de entrada salida cumple los requisitos de la normativa SELV Conexi n del cable de alimentaci n el ctrica Precauci n Los productos Sun est n dise ados AN para trabajar en una red el ctrica monof sica con toma de tierra Para reducir el riesgo de descarga el ctrica no conecte los productos Sun a otro tipo de sistema de alimentaci n el ctrica P ngase en contacto con el responsable de mantenimiento o con un electricista cualificado si no est seguro del sistema de alimentaci n el ctrica del que se dispone en su edificio el ctrica tienen la misma capacidad Los cables de tipo dom stico no est n provistos de protecciones contra sobrecargas y
32. s suivants sera peut tre utilis en fonction du type d interrupteur de votre syst me ARRET Votre systeme est hors tension courant alternatif VEILLEUSE L interrupteur Marche Veilleuse est C s en position Veilleuse Modification du mat riel Ne pas apporter de modification m canique ou lectrique au mat riel Sun Microsystems n est pas responsable de la conformit r glementaire d un produit Sun qui a t modifi Positionnement d un produit Sun votre produit Sun et pour l emp cher de surchauffer il convient de ne pas obstruer ni recouvrir les ouvertures pr vues dans l appareil Un produit Sun ne doit jamais tre plac proximit d un radiateur ou d une source de chaleur N Attention pour assurer le bon fonctionnement de Conformite SELV Securite les raccordements E S sont conformes aux normes SELV Connexion du cordon d alimentation fonctionner avec des alimentations monophas es munies d un conducteur neutre mis la terre Pour carter les risques d lectrocution ne pas brancher de produit Sun dans un autre type d alimentation secteur En cas de doute quant au type d alimentation lectrique du local veuillez vous adresser au directeur de l exploitation ou un lectricien qualifi Attention les produits Sun sont con us pour Safety Agency Compliance Statements vii Attention tous les cordons d alimentation n ont pas
33. stems Computer Company Sun Microsystems Limited 4 Omni Way UCHL04 203 Springfield Linlithgow Chelmsford MA 01824 USA West Lothian EH49 7LR Tel 508 442 0599 Scotland United Kingdom Fax 508 250 5059 Tel 1506 670000 Fax 1506 672323 Declaration of Conformity xi xii PCI UltraSCSI Host Adapter Installation Guide June 1997 Contents Preface xvii Installing the Host Adapter 1 Overview 1 Installing the Host Adapter 2 v To Prepare for Installation 2 v To Install the Host Adapter 3 v ToTestthe Installation With SunVTS 5 Understanding UltraSCSI 7 Target Devices 7 Bus Length 8 Cabling and Termination 9 Specifications Single Ended 11 Physical Dimensions 11 Power Requirements 12 Performance Specifications 12 PCI Edge Connector Pin Definitions 13 SCSI Connector Pin Definitions 15 Contents xiii C Specifications Differential 17 Physical Dimensions 17 Power Requirements 18 Performance Specifications 18 PCI Edge Connector Pin Definitions 19 SCSI Connector Pin Definitions 21 xiv PCI UltraSCSI Host Adapter Installation Guide June 1997 TABLE A 1 TABLE B 1 TABLE B 2 TABLE B 3 TABLE B 4 TABLE B 5 TABLE B 6 TABLE C 1 TABLE C 2 TABLE C 3 TABLE C 4 TABLE C 5 TABLE C 6 Tables Bus Restrictions 8 Physical Dimensions 11 Power Requirements 12 Performance Specifications 12 PCI Edge Connector Pin Definitions J1B Top 13 PCI Edge Connector Pin Definitions J1A
34. ter Card Note A single ended host adapter is shown in FIGURE 1 1 There are slight variations in components between the single ended and differential host adapters To Install the Host Adapter Open the system Refer to your system documentation for information about filler panels for your system Attach the wrist strap between your wrist and a metal part of the system chassis For systems with a standby type power switch disconnect the power cord Standby type power switches have a l icon The wrist strap between you and the chassis provides the ground path necessary to safely remove and install the printed circuit boards and components without damaging them Remove the filler panel for the desired slot Refer to your system documentation for information about filler panels for your system Remove the host adapter from its protective bag Chapter 1 Installing the Host Adapter 3 6 Make sure that the switches and jumpers are correctly set For the single ended host adapter confirm the following settings m Make sure that all elements of switches Ul and U2 are off m Make sure that jumper TP9 is open For the differential host adapter confirm the following settings m Make sure that all jumpers TP1 TP2 TP3 TP5 TP6 are open 7 Install the host adapter into the PCI slot in your system Refer to the system documentation for information about mounting details mounting holes standoff locking unlockin
35. uency of your power source match the voltage and frequency inscribed on the equipment s electrical rating label Never push objects of any kind through openings in the equipment Dangerous voltages may be present Conductive foreign objects could produce a short circuit that could cause fire electric shock or damage to your equipment Symbols The following symbols may appear in this book Caution There is risk of personal injury and equipment damage Follow the instructions Caution Hot surface Avoid contact Surfaces are hot and may cause personal injury if touched the risk of electric shock and danger to personal Caution Hazardous voltages are present To reduce health follow the instructions On Applies AC power to the system Depending on the type of power switch your device has one of the following symbols may be used C Off Removes AC power from the system Standby The On Standby switch is in the standby position Modifications to Equipment Do not make mechanical or electrical modifications to the equipment Sun Microsystems is not responsible for regulatory compliance of a modified Sun product Placement of a Sun Product Caution Do not block or cover the openings of your Sun product Never place a Sun product near a radiator or heat register Failure to follow these guidelines can cause overheating and affect the reliability of your Sun pr
36. y Agency Compliance Statements ix x PCI UltraSCSI Host Adapter Installation Guide June 1997 Declaration of Conformity Marketing Part Numbers X6540A X6541A and X6600A Product Names Dual Channel UltraSCSI PCI Host Adapters and associated kits Single Ended and Differential EMC USA FCC Class B This equipment complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This equipment may not cause harmful interference 2 This equipment must accept any interference that may cause undesired operation European Union This equipment complies with the following requirements of the EMC Directive 89 336 EEC EN55022 CISPR22 1995 Class B Compatible Electronics Report Nos C70109J2 C70110K1 EN50082 1 IEC801 2 1991 4 kV Direct 8 kV Air IEC1000 4 3 3 V m 80 AM at 1KHz TEC801 4 1988 1 0 kV Power Lines Signal Lines Not Applicable Safety This equipment complies with the following requirements of the Low Voltage Directive 73 23 EEC EC Type Examination Certificates EN60950 IEC950 1993 TUV Rheinland Certificate 59771525 EN60950 vv Nordic Deviations CB Scheme Certificate pending Supplementary Information This product was tested and complies with all the requirements for the CE Mark I n r K P A i Masa J Et 5 15 97 EL FE 5 15 97 Wayne L Bolivar DATE ohn Shades DATE Manager Qualification Engineering Quality Assurance Manager Sun Microsy

Download Pdf Manuals

image

Related Search

Related Contents

USER MANUAL - Precision Medical  Samsung GT-E2330B Kullanıcı Klavuzu  none RP-34-100 Installation Guide  アーム取扱説明書  MTD 117-070R000 thru 111-078R000 Lawn Mower User Manual    metodo de instalacion de un stent en un manguito de confinamiento.  Cal. 9 mm P.A.K. (Blank Firing) USA  se  Miele DA 6290 D Ext  

Copyright © All rights reserved.
Failed to retrieve file