Home
INSTALLATION INSTRUCTIONS
Contents
1. Top Door Hinge Bottom Adjustment Door Hinge Screws Adjustment Screws rm TT Door panel mounting brackets Top hinge adjustment Bottom hinge adjustment SERVICE INFORMATION INSTALLATION CHECKLIST SERVICE INFORMATION Has all packing material been removed If service is necessary maintain the quality built into your Sub Zero unit by calling a Turn the unit on first is the unit operating Liens properly If not is it plugged in Is the control turned on To obtain the name and number of a Sub Zero authorized service center check the contact amp support section of our website subzero com or call Sub Zero customer service CONTACT INFORMATION Has the unit been secured in place with the anti tip bracket Is the unit level Are all leveling legs at 800 222 7820 making contact with the floor e Sub Z When calling for service you will need the ti Sui Is the power cord plugged into a properly model and serial number of your unit Both 800 222 7820 grounded 3 prong outlet which has been numbers are listed on the product rating plate Wendie installed in accordance with all applicable located inside the cabinet in the upper left SR i subzero com electrical codes2 area of the unit Is the water supplv connected model UC 24C Have you checked for leaks A WARNING Is the kickplate screwed in place If you are storing or disposing of your old refrigerator or fre
2. It is necessary to lift the flap to insert the screws Use as many screws as necessary to hold the door panel in place properly IMPORTANT NOTE After the first three or four mounting screws are in place but not completely tightened close the door and check your panel fit This is the time to make small adjustments Once you are satisfied with the appearance open the door and apply the remainder of the screws Check all screws for tightness The metal frame on the door has numerous mounting holes on each side of the door This is to accommodate the Sub Zero accessory handles and provide for easy attachment of the handle through the door frame If you choose not to use the pre drilled handle mounting holes it will be necessary to fasten the handle from the rear of the door panel only or drill one or more additional holes through the metal frame of the door The illustration below shows how this hole passes through the door frame The hole center is on the small locator groove in the front of the frame A 1 4 6 diameter hole is made in the front wall of the extrusion and a 13 32 11 diameter hole through the rest of the frame Tenon Center Tenon centers at jaw 13 32 11 lt Diameter KI Diameter Door frame cross section UNDERCOUNTER INSTALLATION INSTRUCTIONS OVERLAY PANEL INSTALLATION A CAUTION The model UC 24BG glass door is made with a
3. UNDERCOUNTER INSTALLATION INSTRUCTIONS OVERLAY PANEL INSTALLATION BEVERAGE CENTER MODELS UC 24BG AND UC 24BS Inspect the door panel for the minimum 9 s 16 thickness the finished inside edge and the weight limit Decide if the handle will be attached through the glass door frame or just through the deco rative door panel If it is just through the door panel the handle must be attached first The decorative panel is attached using 8 x 5 8 square drive screws passing through the door frame from the rear behind the gasket into the panel The door panel is marked for screw locations by the use of tenon centers which are temporarily inserted into the 1 4 6 diameter holes in the front of the door frame Refer to the illustration below With the unit secured in place and the door closed the panel is held in the desired position on the door and rapped by hand from the front putting center marks on the rear surface of the panel If the door panel is made of such a material that pre drilling is needed all of the mounting holes should be marked If not only enough holes to hold the panel in place temporarily are necessary The door panel is then lowered from the door frame tenon centers removed the door opened and the screws driven into the panel through the black tape on the door frame using the center marks to locate the screws The screw holes inside the door are hidden under a cover flap on the door gasket
4. bits 4 1 2 m of 1 4 copper tubing and saddle valve 4200880 for the water line model UC 24C Copper tubing cutter model UC 24C Masonite plywood s pressed fiberboard cardboard or other suitable material to protect finished flooring Dimensions in parentheses are in millimeters unless otherwise specified INSTALLATION SPECIFICATIONS 15 1 2 2 51 gt 399 LOCATE WATER LINE MODEL UC24C ONLY WITHIN SHADED AREA TOP VIEW lt 24 610 gt ROUGH OPENING WIDTH 24 610 ROUGH OPENING DEPTH DE ANTI TIP BRACKET LOCATE ELECTRICAL AND WATER LINE MODEL UC24C ONLY WITHIN SHADED AREA 151 2 394 sa FRONT VIEW 341 2 876 ROUGH OPENING HEIGHT 341 a 870 MINIMUM HEIGHT REQUIRED l NOTE Water line is required for model UC 24C oniv 237 8 606 145 90 MAXIMUM 253 8 DOOR SWING 253 8 644 645 Y lt 26 660 m 44 1118 _ gt DOOR CLEARANCE DOOR CLEARANCE NOTE Door swing clearances are based on stainless steel door and handle dimensions OPTIONAL COMPONENTS Optional installa tion components are available through your Sub Zero dealer For questions relative to the installation call Sub Zero at 800 222 7820 UNDERCOUNTER INSTALLATION INSTRUCTIONS ELECTRICAL REQUIREMENTS A 1
5. 15V AC 60 Hz 15 amp circuit breaker and electrical supply are required A separate circuit servicing only this appliance is required The power supply cord has a 3 prong ground ing plug which must be plugged into a mating 3 prong grounding type wall receptacle Follow the National Electrical Code and local codes and ordinances when installing the receptacle For location of the electrical supply refer to the installation specifications illustration on page 3 IMPORTANT NOTE The electrical outlet must be placed so the grounding prong is to the right of the thinner blades The outlet must be flush with the back wall The model UC 24RO is designed and safe for use in outdoor applications When installed outdoors a ground fault circuit interrupter GFCI is required to reduce the risk of electrical shock A GFCI is not recommended for use with other undercounter models and may cause interruption of operation A WARNING Do not use an extension cord or two prong adapter Electrical ground is required on this appliance PLUMBING REQUIREMENTS Model UC 24C comes with an automatic ice maker The illustration on page 3 shows the precise placement of the water line When routing through the side walls you must place the water line within 1 2 13 of the floor and as close as possible to the back wall A minimum of 26 660 of copper tubing is required for the water line Connect the 1 4 water line from the ice maker water
6. UNDERCOUNTER REFRIGERATION INSTALLATION INSTRUCTIONS SUB ZERO SUB ZERO CONTENTS Installation Recommendations Installation Instructions Door Panel Installation Installation Checklist 10 Service Information 11 Features and specifications indicated herein and on the website are subject to change at any time without notice Check our website subzero com for the most up to date specifications SUB ZERO is a registered trademark of Sub Zero Inc UNDERCOUNTER INSTALLATION The importance of the installation of the Sub Zero undercounter unit cannot be overem phasized Installation should be done by a qualified installer Before you begin the installation process it is recommended that you read this entire installation instructions book There are key details that you should take special care to observe during the installation By reading these instructions carefully you will make the installation process easier problem free and most importantly safe Any questions or problems about the installa tion should be directed to your Sub Zero dealer or Sub Zero customer service at 800 222 7820 You can also visit our website at subzero com As you follow these instructions you will notice WARNING and CAUTION symbols This blocked information is important for the safe and efficient installation of Sub Zero equipment There are two types of potential hazards that may occur during installation A CAUTION s
7. ezer please do it safely Remove the doors or tightly secure the properly aligned doors closed Child entrapment accidents can be tragic Is the door panel attached securely and Is the door aligned for proper appearance and operation Have any installation or service problems been noted on the product registration card Has the stainless steel door or panel been inspected for any imperfections This is to be done by the dealer or installer with the customer upon completion of the installa tion NOTE Classic stainless steel panels are covered by a limited 60 day parts and labor warranty for cosmetic defects The information and images in this book are the copyright property of Sub Zero Inc Neither this book nor any information or images contained herein may be copied or used in whole or in part without the express written permission of Sub Zero Inc Sub Zero Inc all rights reserved 11 SUB ZERO INC P O BOX 44130 MADISON WI 53744 4130 800 222 7820 SUBZERO COM
8. ignals a situation where minor injury or product damage may occur if you do not follow instructions A WARNING states a hazard that may cause serious injury or death if precautions are not followed Another footnote we would like to identify is IMPORTANT NOTE This highlights informa tion that is especially relevant to a problem free installation UNDERCOUNTER INSTALLATION INSTRUCTIONS INSTALLATION RECOMMENDATIONS SITE PREPARATION Make sure that the finished rough opening where the undercounter unit is to be installed is properly prepared Refer to the installation specifications illustration for rough opening dimensions door swing clearance and location of electrical and plumbing model UC 24C IMPORTANT NOTE To operate properly the door must open a minimum of 90 Use a minimum 3 76 filler in corner installations to assure a 90 door opening Allow enough clear ance in front of the unit for full door swing IMPORTANT NOTE Make sure the floor under the unit is level with the surrounding finished floor TOOLS AND MATERIALS REQUIRED The following is a list of tools and materials that should be available for proper installation Appliance dolly able to support 130 Ibs 59 kg a Level 2 6 m and 4 1 2 m recommended Phillips and slotted screwdriver sets Wrench set and allen wrench set Crescent wrenches Various sized pliers 5 16 hex bolt nut driver Drill and assorted drill
9. late and drill pilot holes for mounting the brackets It is best to start with a few holes position the bracket drill the remaining pilot holes and then secure the mounting bracket with the 8 x 1 2 screws provided A CAUTION Exercise caution when drilling holes for mounting hardware This is especially critical with inset panels 7 8 gt 215 8 549 22 i O SS 0 301 16 764 RH DOOR SWING 151 16 382 U U 35 8 31 2 31 2 92 89 V 89 eo 0 kr 215 8 549 gt LH DOOR SWING 75 22 151 16 382 35 a 92 t t i m 233 4 603 gt Overlay panel bracket placement Dimensions in parentheses are in millimeters unless otherwise specified m 233 4 603 gt t 10 UNDERCOUNTER INSTALLATION INSTRUCTIONS OVERLAY PANEL INSTALLATION MODELS UC 24R AND UC 24C Before attaching the panel to the door place two screws in the center of each mounting position just enough that the slotted holes on the hinge side door panel bracket will slide under the heads These positioning screws will support the door panel during installation and adjustment Refer to the illustration below Install the door panel by engaging the tabbed bracket to the handle side of the door first and then sliding the hinge side mounting bracket onto the positioning screws on the hi
10. nge side of the door The panel can be adjusted 1 4 6 up and down and side to side Once the door panel is in place and adjusted correctly attach the four remaining 10 x 1 2 screws to the hinge side mounting bracket and install the magnetic decorative caps as shown in the illustration below HINGE ADJUSTMENT IMPORTANT NOTE The undercounter unit should be properly leveled in position before door hinge adjustments are made The top and bottom cabinet hinges are held in place with three permanent adjustment screws lf the door needs adjustment loosen the adjustment screws and reposition the door Once in position tighten the adjustment screws Refer to the illustrations below INSTALLATION CHECKLIST The importance of the installation of the Sub Zero undercounter unit cannot be overem phasized Proper installation is the responsibil ity of the selling dealer or installer IMPORTANT NOTE The following checklist should be completed by the installer to ensure that no part of the installation has been overlooked Advise the homeowner to fill out and return all product registration forms This will ensure that the customer information is in our database in the event service is required Any questions or problems about the installa tion should be directed to your Sub Zero dealer or Sub Zero customer service at 800 222 7820 You can also visit our website at subzero com Door Panel Bracket
11. panel and tubular pro or curved handle in place No panel installation is required IMPORTANT NOTE Model UC 24RO must be built into cabinetry and cannot be used in a free standing application Dimensions in parentheses are in millimeters unless otherwise specified BEVERAGE CENTER MODELS UC 24BG AND UC 24BS Classic stainless steel models UC 24BG S and UC 24BS S are shipped from the factory with the classic stainless steel door and tubular pro or curved handle in place No panel installation is required For overlay model UC 24BG O a decorative frame door panel must be provided to surround the glass The door panel must be 233 4 603 by 301 16 764 with rails and stiles a minimum of 21 4 57 wide The overlay panel must be a minimum of s 16 thick and has a weight limit of 10 Ibs 5 kg for glass door models and 20 Ibs 9 kg for solid door models Installation of the overlay door panel for models UC 24BG O and UC 24BS O is outlined on the following pages You may also use your own handle hardware to match surrounding cabinetry If you do not use the pre drilled holes on the door of the unit you will need to attach the handle directly to the overlay panel IMPORTANT NOTE For installations at or above 5 000 1524 m in altitude a special high altitude glass door unit must be ordered A CAUTION A solid panel must not be installed on a glass door unit as this may cause moisture to form behind the panel
12. r unit Position the dolly at the back of the unit to prevent damage to finished surfaces A CAUTION Before moving the undercounter unit into position protect any finished flooring with appropriate materials and secure the door closed Dimensions in parentheses are in millimeters unless otherwise specified POSITION THE UNIT IMPORTANT NOTE If the undercounter unit has been laid on its back or side you must allow the unit to stand upright for a minimum of 24 hours before connecting power Plug the power supply cord into the 15 amp grounded electrical outlet With power applied to the appliance check for lighting and cooling before going any further Once you are satis fied that the unit is operating properly shut off power to the electrical outlet at the circuit breaker and proceed A WARNING Shut off the power to the electrical outlet Pre level the unit before sliding it into position Leveling cannot be completed with the unit pushed back in the installation opening The undercounter unit provides the best access to its contents when the front surface of the door panel extends out from surrounding cabinets approximately 1 4 6 IMPORTANT NOTE The floor under the undercounter unit must be at the same level as the surrounding finished floor to allow for removal of the unit for servicing UNDERCOUNTER INSTALLATION INSTRUCTIONS ANTI TIP BRACKET INSTALLATION A WARNING To prevent the unit from tipping fo
13. rward and provide a stable installation the unit must be secured in place with the anti tip bracket An anti tip bracket and hardware is provided with the undercounter unit The anti tip bracket must be installed on a solid base to prevent tipover in case several loaded wine shelves are extended at the same time The anti tip bracket should be attached to the wall behind the unit with the bracket flange located immediately above the top of the unit Refer to the illustration below A smaller metal countertop bracket is also provided with the undercounter unit for instal lations that need to be modified to provide a secure surface for attaching the bracket This bracket will secure the front of the unit to the underside of the countertop above the unit Refer to the illustration below If it is not possible to use the countertop bracket wedge shims along the sides and top of the unit LEVEL THE UNIT Using an adjustable wrench or pliers turn each of the four leveling legs clockwise to raise the unit and counterclockwise to lower the unit For the location of the leveling legs refer to the illustration below A WARNING To reduce the possibility of the unit tipping forward the front leveling legs must be in contact with the floor KICKPLATE INSTALLATION Once the unit is leveled the kickplate can be installed Use the two 10 x 1 2 stainless steel screws that are provided with the kickplate Refer to the ill
14. sealed double wall tempered glass core The drill must not contact this core when drilling Be sure the hole is centered on the small groove in the front of the door frame and the drill passes squarely through the frame If you are inexperi enced with drilling fasten the handle from the rear of the door panel only IMPORTANT NOTE For model UC 24BG install screws in all the mounting holes in the door frame The nature of the door panel with a narrow outer rim and no connecting center member requires the support provided by the glass door After the door panel installation is complete apply the cover patches or plugs provided over the holes on the inside surface of the door A CAUTION The cover patches or plugs are part of the insulation system on the door of the undercounter unit Be sure to cover all the holes in the door that were used MODELS UC 24R AND UC 24C Remove the two panel mounting brackets attached to the front of the door and set aside Place the overlay door panel lying face down on a protected surface to ensure that the front is not scratched or damaged Position the plastic template provided flush with the lower edge of the door panel Be sure you are following the exact location for the right hand RH or left hand LH door swing Refer to the illustrations below for placement of the mounting brackets Once you have located the proper placement for the brackets mark the pilot holes remove the temp
15. ustration below IMPORTANT NOTE The kickplate must be removed for servicing The floor cannot inter fere with removal The louvered section of the kickplate must not be covered so as to prevent air circulation Turn power back on to the electrical outlet Countertop Bracket Leveling Legs Anti tip bracket installation Countertop bracket installation Location of leveling legs Kickplate installation UNDERCOUNTER INSTALLATION INSTRUCTIONS DOOR PANEL INSTALLATION MODELS UC 24R AND UC 24C Models UC 24R and UC 24C can be fitted with a custom overlay or stainless steel door front panel A classic stainless steel door panel with tubular pro or curved handle is available as a sales accessory Installation of the stainless steel panel will be required For the overlay application a decorative door panel and handle hardware must be provided You can match your handle hardware with surrounding cabinetry or use a Sub Zero accessory handle Handles must be attached directly to the overlay panel The overlay application requires a decorative door panel 233 4 603 by 301 16 764 The overlay panel must be a minimum of s 16 thick and has a weight limit of 20 Ibs 9 kg Installation of the overlay door panel for models UC 24R and UC 24C is outlined on the following pages OUTDOOR MODEL UC 24RO Model UC 24RO is shipped from the factory with the classic stainless steel door
16. valve to the house water supply Use an easily accessible shut off valve between the water supply and the unit This shut off valve should not be installed behind the unit Do not use self piercing valves A saddle valve kit 4200880 is available from your Sub Zero dealer A line filter is required when water conditions have a high sediment content The ice maker operates on water pressure of 20 psi 1 4 bar to 100 psi 6 9 bar A reverse osmosis system can be used provided there is a consistent water pressure of 20 psi 1 4 bar to 100 psi 6 9 bar supplied to the water valve at all times IMPORTANT NOTE In some cases a reverse osmosis water filter system may not be able to maintain the minimum water pressure consistently UNDERCOUNTER INSTALLATION INSTRUCTIONS UNPACKING AND MOVING Uncrate the unit and remove its wood base Remove all packing materials and tape IMPORTANT NOTE Do not discard the kickplate anti tip bracket hardware and the shipping bolts that hold the wood to the bottom of the unit leveling legs These items will be needed for the installation Roller assembly wine shelves should be removed to reduce weight and prevent them from rolling models UC 24BG UC 24BS and UC 24C To remove pull the shelf out to its full extension gently and evenly lift up on both sides of the front of the shelf and remove Reverse the procedure to reinstall the shelf Use an appliance dolly to move the under counte