Home

MVP 8400i Quick Start Guide

image

Contents

1. 2 Select Type to toggle between USB and Ethernet 3 When using Ethernet press the listed Mode to toggle through the available connection modes Connection Modes Moge Deserpion Procedures Auto The device connects to the first Setting the System Number master that responds This 1 Select the System Number to open the setting requires you set the keypad System Number 2 Set your System Number select Done URL The device connects to the Setting the Master IP specific IP of a master via a TCP connection This setting requires you set the Master s IP 2 Set your Master IP and select Done Confirm device IP is on the Master URL list You can set the Host Name on the device and use it to locate the device on the master Host Name is particularly useful in the DHCP scenario where the IP address can change 1 Select the Master IP number to the keyboard Listen The device listens for the master to initiate contact This setting requires you provide the master with the device s IP 4 Select the Master Port Number to open the keypad and change this value The default setting for the port is 1379 5 Set your Master Port and select Done For full warranty information refer to the AMX Instruction Manual s associated with your Product s 12 07 2007 AMX All rights reserved AMX and the AMX logo are registered trademarks of AMX AMX reserves the right to alter specifications without notice at a
2. paag aw Overview The AMX MVP 8400i panel FG5965 04 uses an internal wireless compact flash card to communicate with a NetLinx Master via a standard 802 11g Wireless Access Point Panel to panel communication is enabled via a full duplex VoIP intercom interface The MVP 8400i utilizes a 8 4 Color Active LCD to display a 800 x 600 pixel image using over 256 K colors and features programmable firmware that can be upgraded via either the wireless card or the mini USB port The MVP 8400i also features nine programmable external pushbuttons and two sets of programmable LEDs On the 4 available IR channels this panel utilizes both AMX IR frequencies 38 KHz or 455 KHz and 2 additional user defined IR libraries For detailed installation configuration programming file transfer and operating instructions refer to the MVP 8400i Modero ViewPoint Touch Panels operation reference guide available on line at www amx com Directional pad w center select button Mini USB Pushbuttons 4 connector J Microphone a Stylus gt f DAT et Na tt i D DAN DAT HAG A EG Speaker Speaker Docking station interface connector Speaker Power connector FIG 1 MVP 8400i Touch Panel components Specifications MVP 8400i Specifications FG5965 04 Dimensions HWD 7 17 x 10 47 x 1 34 18 20 cm x 26 60 cm x 3 40 cm Power Requirement Panel with batteries fully charged or with no batteries witho
3. Panel with two batteries 2 65 lbs 1 20 kg e Screen resolution 800 x 600 pixels HV 60 Hz frame frequency e Aspect ratio 4 x 3 e Brightness luminance 180 cd m2 e Channel transparency 8 bit Alpha blending e Contrast ratio 350 1 e Display colors 256K colors 18 bit color depth e Dot pixel pitch 0 21 mm e Panel type TFT Color Active Matrix Viewing Angle e Vertical 60 up from center and 40 down from center Operating Storage Operating Temperature 0 C 32 F to 40 C 104 F Environments e Operating Humidity 20 85 RH e Storage Temperature 20 C 4 F to 60 C 140 F e Storage Humidity 5 85 RH Screen Properties Included Accessories e Wireless Interface Compact Flash card CF Type 1 pre installed into MVP e PS4 4 Power Supply FG423 44 e Stylus pre installed onto the left side of the unit e Two MVP BP Power Packs FG5965 20 Other AMX Equipment e CB MVPWDS Conduit Box FG037 10 e CC USB Type A to mini B programming cable FG10 5965 e MVP BP battery FG5965 20 e MVP KS Kickstand FG5965 12 e MVP STYLUS three pack FG5965 30 e MVP TDS Table Top Docking Station FG5965 10 e MVP WDS Wall Docking Station Black FG5965 11 e MVP WDS Wall Docking Station Silver FG5965 21 e MVP WDS SK Silver Conversion Kit FG5965 22 e Upgrade Compact Flash pre programmed with firmware NXA 84CF 128M 128 MB compact flash card FG2116 50 NXA 84CF256M 2
4. 56 MB compact flash card FG2116 51 NXA 84CF512M 512 MB compact flash card FG2116 52 NXA 84CF1GB 1 GB compact flash card FG2116 53 Connections and Wiring The PS4 4 Power Supply with barrel connector provides power to the MVP 8400i either directly via the power connector located on the lower right side of the panel or indirectly by routing incoming power through the Docking Station s MVP Interface Connector e Once the MVP is connected to a docking station charging priority is first given to any MVP BP battery packs found within the MVP 8400i and then to any other batteries inserted into the docking station s battery charging compartments Warning Although firmware upgrades can be done over wireless Ethernet it is strongly recommended that firmware KIT files be transferred over a direct USB connection and only when the panel is connected to a power supply If battery power or wireless connection fails during a firmware upgrade the panel flash file system may become corrupted Setup Pages The panel is equipped with setup pages that allow you to set and configure various features on the panel Consult the MVP 8400i Modero ViewPoint Touch Panels operation reference guide for detailed information on the Setup pages Accessing The Protected Setup Page 1 Press down and hold both the bottom left pushbutton and down on the directional pad indicated in FIG 1 simultaneously for 3 5 seconds This opens the Setup page 2
5. Press Protected Setup button on the Setup page This opens a keypad for password entry 3 Enter the panel password into the keypad default is 7988 and select Done to access the Protected Setup page Setting the Panel s Device Number In the Protected Setup page 1 Press the Device Number field to open the Device Number keypad Enter a unique Device Number assignment for the panel and press Done to return to the Protected Setup page 2 Press Reboot to reboot the panel and apply the new Device Number Configuring the Panel s Wireless IP Settings The first step is to configure the wireless communication parameters this only configures the card to communicate to a target WAP it is still necessary to tell the panel which Master it should be communicating with see Master Connection Consult the MVP 8400i Modero ViewPoint Touch Panels operation reference guide for setting the wireless communication using a static IP address Wireless Communication Using a DHCP Address In the Protected Setup page 1 Select Wireless Settings Wireless communication is set within the IP Settings section of this page 2 Toggle the DHCP Stfatic field from the IP Settings section until the choice cycles to DHCP This action causes all fields in the IP Settings section other than Host Name to be greyed out Do not alter any of these remaining greyed out fields in the IP Settings section Once the panel is rebooted these values are obtained by th
6. ayed in other panels intercom call directory pages Consult the MVP 8400i Modero ViewPoint Touch Panels operation reference guide for more intercom setup features 1 Select the Setup button on your intercom page 2 On the intercom setup page press Advanced Setup This launches the password numeric keypad 3 Enter the password and press Done The default password is Password 4 of the panel s firmware Password Setup Naming a Panel In the intercom Advanced Setup page 1 Press in the area under Panel Name This launches an on screen keyboard 2 Type the name of the panel and press Done This is the name that is displayed in other panels intercom call directory pages 3 Press Back to return to the intercom setup pages 4 Press Exit when you are finished Note The Panel Name is also the G4 Web Control Name and can be set via the panel s firmware pages Related Documents e MVP 8400i Modero ViewPoint Touch Panels operation reference guide e MVP TDS Table Docking Station operation reference guide e MVP WDS Wall Docking Station operation reference guide e MVP KS KickStand operation reference guide e VisualArchitect operation reference guide e G4 PanelBuilder operation reference guide e TPDesign4 Touch Panel Design Program operation reference guide Caution There are particular operations such as upgrading the NXA CFSP compact flash card and replacing installing the NXA WC80211GCF Wireless Compact Flash Card
7. e unit and displayed in the DNS fields after power up Consult the MVP 8400i Modero ViewPoint Touch Panels operation reference guide for setting a Host Name Configuring the Card s Wireless Settings This section configures both the communication and security parameters from the internal wireless card to the WAP Once you have set up the wireless card parameters you must configure the communication parameters for the target Master see Master Connection Consult the MVP 8400i Modero ViewPoint Touch Panels operation reference guide for configuring the wireless card for unsecured access to the WAP Configuring The Wireless Card for Secured Access To the WAP In the Protected Setup page 1 Select Wireless Settings 2 Enter the SSID information automatically by pressing the Site Survey button 3 Selecta WEP secured WAP from within the Site Survey page and press the Connect button 4 Write down the SSID name Current Key string value and panel MAC Address information so you can later enter it into the appropriate WAP dialog fields in order to sync up the secure connection These values must be identically reproduced on the target WAP Consult the MVP 8400i Modero ViewPoint Touch Panels operation reference guide for manually entering the SSID information Master Connection The panel requires you establish the type of connection you want made between it and your master In the Protected Setup page 1 Select System Settings
8. ny time 3000 RESEARCH DRIVE RICHARDSON TX 75082 e 800 222 0193 e fax 469 624 7153 technical support 800 932 6993 www amx com If you have enabled password security on your master you need to set the username and password within the device 6 Select the blank field Username to open the keyboard 7 Set your Username and select Done 8 Select the blank field Password to open the keyboard 9 Set your Password and select Done 10 Press the Back button to return to the Protected Setup page 11 Press the Reboot button to reboot device and confirm changes Touch Panel Calibration In the Protected Setup page follow these steps 1 Select Calibrate 2 Touch each target on the screen as they appear Once calibrated the panel confirms and instructs you to touch the screen to continue Panel Intercom Configuration Incorporating an intercom capable panel into your NetLinx system Download the module for the intercom panel from www amx com and include itin your NetLinx project file For searching purposes the module manufacturer is AMX and the model is Intercom Note The intercom module will only work with AMX intercom capable panels Advanced Setup The intercom s advanced setup pages are accessed through the intercom setup pages The advanced pages allow you to set the panel intercom to be monitored to monitor other intercom panels and to name the panel It is important to name the intercom panel the name is displ
9. that require opening the MVP s outer housing to access internal components as described in the MVP 7500 Modero ViewPoint Touch Panels Operation Reference Guide When opening the MVP panel housing to access internal components be careful not to damage or disconnect the wireless compact flash card antenna which is mounted to the inside of the rear housing 93 5965 22 REV C POUT aT BA EP
10. ut charging Constant current draw 1 3 A 12 VDC e Startup current draw 1 9 A 12 VDC e If panel is mounted onto a TDS or WDS add 0 1 A to the above figures Power Requirement Panel while charging batteries while charging e Constant current draw 3 3 A 12 VDC e Startup current draw 3 9 A 12 VDC e If panel is mounted onto a TDS or WDS add 0 1 A to the above figures PS4 4 Power Supply FG423 45 All MVP models are shipped with this power supply Minimum power supply required Power Modes e ON Panel is fully functional e STANDBY Panel uses low power the LCD backlight is shutdown LEDs still function Panel resumes the ON mode in 1 second e OFF On board programs not running touch screen still powered LED not functional Panel resumes the ON mode in 30 seconds Certifications e FCC Part 15 Class B and CE IEC60950 Battery Duration e Eight hours of normal use 25 On state 25 Standby using 2 batteries and 50 Off e Four hours of continuous use continuous On state The MVP 8400i ships with two MVP BP batteries You must use both batteries to obtain the duration times given above e 128 MB SDRAM e 128 MB Compact Flash upgradable to 1 GB factory programmed EOC MvP 8400i Quick Start Guide Modero Wireless Touch Panel w Duplex Intercom MVP 8400i Specifications Cont e Panel no batteries 1 85 Ibs 0 84 kg e Panel with one battery 2 25 Ibs 1 02 kg e