Home

User Manual - Skope Industries

image

Contents

1. When positioning the cabinet a gap of at least 200mm must be left above the refrigeration unit The back of the cabinet can be positioned hard against a wall however a gap of 50mm is recommended to prevent moisture build up IMPORTANT To ensure efficient and reliable operation a minimum of 200mm clear ventilation space is required above the refrigeration unit Ceiling Min 200 mm A E Airflow Wall Vi 50mm Front of cabinet Installation User Manual SKOPE Pegasus Vertical Series Castors Plinth Mounting Legs Positioning the Cabinet The cabinet is supplied fitted with castors as standard and includes a set of adjustable height legs packed inside the cabinet Alternatively the cabinet may be supplied ready for plinth mounting The adjustable castors can be used to adjust the cabinet height up or down through a 15mm range Refer to the procedure below to adjust the castors When adjusting the castors ensure the lock nut is re tightened after the final adjustment has been made CAUTION Ensure the castor lock nut is re tightened after castor adjustment To adjust castor height 1 Loosen the lock nut Lock nut 2 Turn the castor counter clockwise to raise the height or clockwise to lower Re tighten each lock nut after final adjustment has been made Castor lock Once the cabinet height and position has been set lock the cabinet in place with the two front castor locks one on each cast
2. C for chillers and 40 C for freezers This appliance will generally use less power when installed in a cooler location When installing the cabinet o Avoid direct sunlight and warm draughts etc o Allow adequate space for the door s to open fully o Ensure the cabinet is positioned on a level surface so the door s shut and seal correctly and to prevent the condensate tray from overflowing o The self closing door s have internal torsion bars pretensioned at the factory and should not require any further adjustment a Do not overload the power supply See the rating label inside the cabinet for power supply and current draw o Ifa remote refrigeration system is being installed installation must be done by a qualified refrigeration tradesperson Refer to page 10 for information Power Supply The cabinet is supplied with a 1 8m flexible power cord fitted with a 3 pin plug which exits out the rear of the refrigeration unit The power cord should be retrieved before the cabinet is positioned as wall and partitions may make access difficult CAUTION Do NOT overload the power supply See the rating label inside the cabinet for power supply and current draw Installation User Manual SKOPE Pegasus Vertical Series Ventilation For efficient operation of the chiller it is essential that adequate ventilation be provided above the refrigeration unit Never store cardboard cartons or other items on top of the refrigeration unit
3. 00 0 cece eens 16 Troubleshooting nonna 0 00 ee eee 17 SKOPE Pegasus Vertical Series User Manual SKOPE Pegasus Vertical Series 1 Models Chillers Refrigeration Operating temperature PG600VC H11PV Integral PG1300VC H12PV Integral 1 C to 4 C up to 43 C PG6O0VCr RHTIPV ambient PG1300VCr RH12PV Freezers Refrigeration Operating temperature PG600VF H21PV Integral PG1300VF H22PV Integral 18 C to 21 C up to 40 C PGSOOVEr _ RH21PV ambient PG1300VFr RH22PV 4 Models User Manual SKOPE Pegasus Vertical Series 2 Installation Safety First Always observe safety precautions when using any electrical appliance Read these instructions carefully and retain them for future reference o When the appliance is used by or near young children or infirm persons close Supervision is necessary especially to ensure children do not play with it Do not use this appliance for other than its intended use Do not cover the grilles or block the entry or exhaust of airflow by placing objects up against the refrigeration unit Do not probe any opening Only use this appliance with the voltage specified on the rating label Ensure the appliance has adequate ventilation as this is essential to economical high performance Be careful not to touch moving parts and hot surfaces For your own safety and that of others ensure that all electrical work is done by authorised personnel o Ifthe power supply flexible cord bec
4. by an LED tube fitted behind the diffuser at the top Interior Lights of the cabinet PG600 or behind the centre pillar PG1300 See the table below for LED tube specifications LED tube specifications Cabinet SKOPE part No PG1300VC Ecopoint 20W 1200mm T8 LED tube ELL10436 To replace the interior LED light tube 1 Disconnect the chiller from the mains power supply 2 Remove the diffuser by squeezing it until it is released from the housing and then push the diffuser out of the way single door cabinet pictured for clarity 3 Rotate the LED tube until the pins on the ends of the tube align with the slots then slide it out 4 Fita new LED tube and clip the diffuser back into place Reconnect to the power supply Servicing 15 User Manual SKOPE Pegasus Vertical Series Cabinet Condenser Coll 16 Cleaning When necessary wipe both the interior and exterior of the cabinet with a damp cloth Ensure the cabinet is disconnected from the mains power supply before cleaning the cabinet Periodic cleaning of the condenser coil is also required WARNING Disconnect the cabinet from the mains power supply before cleaning the condenser coil or washing the cabinet Integral cabinets only The condenser coil is situated behind the unit front panel The condenser coil MUST be kept clean for reliable operation and to minimise power consumption a blocked condenser can double power consumption To ensu
5. is connected to the power supply the electronic controller Controller will display the current cabinet temperature On the controller display the symbol will indicate the compressor output signal has been initiated and the symbol will indicate the evaporator fan is on Installation Refer to the diagram below remote chiller unit pictured for component Diagrams locations and unit access points Pegasus Vertical Remote installation diagram Optional Solenoid Valve Optional Solenoid Valve Drain Hose Drain Hose Suction Liquid Line Outlets Suction Liquid Line Outlets PG600 remote PG1300 remote viewed from the side viewed from the front 10 Installation User Manual SKOPE Pegasus Vertical Series 3 Operation Refrigeration Unit Electronic Controller Operation User Manual Cabinet Lighting HACCP Automatic Start Up Connect the cabinet to the mains power supply and check operation of the refrigeration unit electronic controller and cabinet lighting Integral The compressor and the condenser and evaporator fans should all operate within two minutes from the time the cabinet is plugged in This may be verified by listening for compressor switch on and checking for air movement inside the cabinet The compressor and condenser fan will switch off when the cabinet internal temperature reaches 2 C Remote The evaporator fan should operate within five minutes from the time the cabinet is
6. oo sc ciao ada he e Ge a 6 Installation Guidelines o ooooooooooooooooo oo 6 Power Supply 0 0 0c ee eee ees 6 Ventilation 2 0 ee ee eee T Positioning the Cabinet 0 00 00 eee 8 CaSlOS shun heer Garde bueny esto rd atesora des 8 PIMA MOUNUNG sda 220 em se 64 nee 00 eee oho a 8 LCOS Suid cess eee ae Gta ae eee ae woah eee de et ee 8 SNCIWING sd snaueoweeneua nse Oba eee oe ee oe poa 9 Loading Product sir o a e A ci 9 DOOF LOCK ames aerea e ee See bu oe eee es 9 Remote Cabinet Installation o ooooooooooo 10 SDECIICAUONS be d544 ob deb oh hSSeGa ee Rees doe oe eS ds 10 Electronic Controller 0 0 0000 cee eee 10 Installation Diagrams 0 0 ees 10 3 Operation Automatic Start Up 0 0 0 ee 11 Refrigeration Unit a na naaa aaa aaa eee 11 Electronic Controller oo ooooooooooooooo 11 Cabinet LIQNUNG lt lt airada oy eS 44 gee sede a ela is 11 HACCP escasean dns Geese ibas ia ada ea a 11 Electronic Controller o o o ooooooooooooooooo 12 Controller Overview o o oooooooooonooo o ee 13 Temperature Setpoint 0 0 0 ce nn 13 Controller Alarms 4 Servicing Een alo 2 E E Seated G quae ea keene oe Ae ak one oS EN 15 Cabinet Interior Lights 0 00 00 cee eee ees 15 Cleaning gt 390 noes Bo eee eed eee aptas eee a 16 CAD 2 eo a Se a eet A eed eee o Oe es eee nee 16 Condenser Coil
7. operating integral cabinets only and the evaporator fan LED will normally come on within 2 minutes SKOPE do not recommend that the setpoint be changed unless it is absolutely necessary and then only by small increments at a time Chillers The chiller temperature setpoint is factory set at 2 0 C If necessary the standard setting can be adjusted between 1 5 C and 3 5 C Freezers The freezer temperature setpoint is factory set at 18 C If necessary the standard setting can be adjusted between 18 C and 21 C To view and adjust the temperature setpoint 1 To view the setpoint Press and hold the Set key for 2 seconds until the setpoint value flashes 2 To adjust the setpoint a Press either the A or y keys to display the required setpoint value 3 Press the Set key again to memorise the new setpoint value If this is not done within 60 seconds changes will be lost and you will need to repeat the above procedure 13 SKOPE Pegasus Vertical Series Controller Alarms Product HIGH 1 Check the cabinet product loading to ensure ventilation temperature alarm slots are not blocked and that product does not overhang auto reset the shelves Ensure the doors are closed 2 Ensure the cabinet is installed with good refrigeration unit ventilation 3 Check and clean the condenser coil see page 16 Product LOW 4 If immediate alarm recovery is required unplug the temperature alarm cabinet from the po
8. User Manual MAN2787 Rev 4 0 Nov 2013 SKOPE PEGASUS PG Vertical Series Chillers and Freezers PG600VC PG1300VC SKOPE Refrigeration SKOPE Warranty Protection To activate your Warranty Protection you must register your product with SKOPE within 4 weeks from date of invoice To register online ee Visit our website at www skope com warrantyprotection Ee mabe then complete and submit the online registration form Or alternatively contact our Customer Services team to register 1800 121 535 Australia 0800 947 5673 New Zealand SKOPE 1 year Extended Warranty Extend your Warranty Protection by 1 year during registration Please check you have not already organised an extended warranty through your dealer at time of purchase For pricing information on an extended warranty visit www skope com warrantyprotection Service amp Support We know you will get years of satisfaction from your new SKOPE product when you follow a few simple preventative maintenance guidelines Helpful information is available on our website Ono www skope com serviceandsupport i y Thank you for purchasing a SKOPE refrigeration product CONTENTS 1 Models GRISES 0 cos ca pa ow xe cg we dew odes wr ee ow eae wre es haw dwn eee 4 FreezerfS ouaaa als oe coe ee Oo ob ae Ea Oe eee Bee 4 2 Installation Safety First 2 era ad ae dde reed Se a id t 5 Locating the Cabinet o ooocococoononoo eee 6 LOCAU ona tu aon a aaa Be
9. lays and or enables changing the temperature setpoint 4 ser Manual defrost down Press for more than 5 seconds to initiate manual defrost To scroll settings down in program mode Compressor ON when the compressor and condenser fan starts Flashes when activation of the compressor is temporarily delayed Fan Shows when the fan is operational Defrost ON when the defrost is activated Flashes when the activation of the defrost is temporarily delayed due to procedures in progress al 00 aux Aux n a Alarm Flashes in the event of alarms Clock n a o 11 gt Light n a 12 Service Flashes in the event of malfunctions 13 coc DISPLAY Shows the cabinet temperature Flashes when the I o OL door is open HACCP HACCP n a D 15 e CONTINUOUS CYCLE On when freezer is running in continuous Oe run mode 42 Operation User Manual Controller Overview Temperature Setpoint Operation User Manual SKOPE Pegasus Vertical Series The CAREL ir33 electronic controller controls and displays the internal cabinet temperature The electronic controller also signals temperature alarms see page 14 For general operation the electronic controller requires no initial setup or additional programming When the cabinet is connected to the power supply the electronic controller will display the current cabinet temperature The compressor LED will indicate the compressor is
10. omes damaged it must be replaced by an authorised service agent or similarly qualified person in order to avoid a hazard o Ensure all necessary safety precautions are observed during installation or removal of the refrigeration unit o The appliance is not designed to be stable while in motion Use extreme caution when moving or transporting it a Do not store explosive substances such as aerosol cans with a flammable propellant in this appliance o Please contact SKOPE Customer Services for advice regarding disposal of this appliance CAUTION Overloading the power supply could damage the appliance and product Check the rating label inside the cabinet for the safe power supply and current draw WARNING Always disconnect the cabinet from the mains power supply before cleaning or maintenance Installation 5 User Manual SKOPE Pegasus Vertical Series Location Installation Guidelines Locating the Cabinet When positioning the cabinet avoid direct sunlight and warm draughts etc The cabinet must NOT be situated where it is affected by warm or hot air from adjacent equipment as this will compromise the airflow and performance of the chiller The cabinet must be positioned on a level surface for the doors to shut and seal correctly and to prevent the condensate tray from overflowing Adequate allowance should be made for door opening The maximum recommended ambient temperature at place of installation is 43
11. or Plinth mount cabinets have a flat base and are fitted with a plinth surround ready for positioning in place The adjustable legs can adjust the cabinet height up to 30mm They screw into the castor mounting plates attached to the bottom of the cabinet The legs should be fitted to the base of the cabinet before final positioning of the chiller To adjust leg height Castor 1 Turn the black plastic foot Mounting plate at the bottom of the leg counter clockwise to raise Adjustable leg the height or clockwise to lower Plastic foot Installation User Manual SKOPE Pegasus Vertical Series Shelving The cabinet is supplied with two sets of shelves and shelf support brackets per door The shelves can be positioned at different heights to suit various products To fit the shelves 2 Unpack the shelving items from inside the cabinet 3 Establish the desired position for each of the shelves based on the height of the product intended to go on each shelf 4 Fit the stainless steel tray slides into the corresponding slots in both the front and back support rails Each shelf requires two tray slides 5 Slide each wire shelf into the corresponding pair of tray slides y LA h prva in i F d gt iA jn oll o A Ss s g O AM a Loading The cabinet should be left running for 30 minutes before loading with Product product When loading the cabinet shelves with product a Ens
12. plugged in Note Freezers may take longer depending on evaporator temperature The electronic controller is located behind the unit front panel When the cabinet is connected to the power supply the electronic controller will display the current cabinet temperature The compressor LED will indicate the compressor is operating The evaporator fan LED will normally come on within 2 minutes see page 11 for controller display To ensure efficient operation the electronic controller forces six hourly defrosts During the defrost cycle the compressor and condenser fan switches off and the evaporator fan stays on The interior lighting will go on when a cabinet door is opened The only time that a light should not turn on is either if an LED tube is faulty or the CHt high temperature shutdown alarm has been activated see page 14 for controller alarms To replace an LED tube see service instructions on page 15 lf Hazard Analysis Critical Control HACCP functions are required to monitor food storage temperature please contact SKOPE to arrange for an authorised SKOPE service technician to setup the electronic controller 11 SKOPE Pegasus Vertical Series Electronic Controller Item Mute program Mutes the audible alarm buzzer and 1 Prg deactivates the alarm relay To initiate program sets press for 5 seconds Up To scroll settings up in program mode Set point If pressed for more than 2 seconds disp
13. r packaging has been altered in any manner e Alters removes including part removal or obliterates including part obliteration the trade mark on the product e Applies any other trade mark to the product e Adds to the product any written material that is likely to damage the reputation of the trade mark Notice of the above contractual obligations passes to e Successors or assignees of the buyer e Future owners of the product SKOPE Pegasus PG Vertical Series Chillers and Freezers User Manual MAN2787 Rev 4 0 Nov 2013 2006 SKOPE Industries Limited All rights reserved SKOPE Industries Limited reserve the right to alter specifications without notice SEKOPE is a registered trademark of SKOPE Industries Limited
14. re trouble free performance the condenser coil should be brushed clean once a month and blown clean by qualified service personnel every six months Over time dust may accumulate within the condenser that cannot be removed with a brush if this occurs contact SKOPE to arrange for a SKOPE Authorised Service Agent to clean the condenser with compressed air IMPORTANT If the electronic controller display flashes cht the condenser coil must be cleaned immediately To access the condenser coil 1 Disconnect the chiller from the mains power supply 2 Remove the refrigeration unit front panel from the cabinet by pulling the bottom of the panel out to unclip from the side panels and then lift the panel up off the cabinet Refitting the front panel is a reversal of this procedure 3 The condenser coil is now accessible for cleaning Servicing User Manual Servicing User Manual SKOPE Pegasus Vertical Series Troubleshooting Possible Cause Complaint 1 Cabinet not e Loss of power supply operating and no controller display 2 Cabinet lights Failed LED light tube not operating e Controller high temperature shutdown alarm CHt e Cabinet ENSTO supply plug not plugged into control box 3 Power e Unit operating too hot consumption is higher than expected e Cabinet doors are opened excessively 4 Product is too Restricted cabinet airflow warm and spoiling e Tempera
15. ture setpoint is too warm 5 Warm cabinet Blocked condenser temperatures and or e Poor refrigeration unit compressor ventilation operating for long periods more than 1 hour Repair e Check mains power supply e Replace LED light tube see page 15 e Determine cause and eliminate see ppage 14 e Reconnect plug e Clean condenser integral cabinets only e Ensure the chiller is installed with good ventilation above the refrigeration unit e Keep door s open for minimum time e Ensure product is not blocking airflow slots and the product is no closer than 50mm from the cabinet top e Adjust setpoint see page 13 e Clean condenser see page 16 e Ensure the cabinet is installed with good ventilation around the front and top of the refrigeration unit see page 9 17 SKOPE Contacts SKOPE Industries Limited NEW ZEALAND CONTACT Head Office PO Box 1091 Christchurch New Zealand Freephone 0800 947 5673 Fax 03 983 3896 E mail enquiry skope co nz Website www skope co nz AUSTRALIAN CONTACT A B N 73 374 418 306 PO Box 7543 Baulkham Hills B C NSW 2153 Australia Freephone 1800 121 535 Fax 1800 121 533 E mail enquiry skope com au Website www skope com au Trademark Infringement The SKOPE trademark on this product is infringed if the owner for the time being does any of the following e Applies the trade mark to the product after their state condition get up o
16. ure all shelves are securely fitted see above o Allow air space around all the product to ensure even cooling and efficient operation of the chiller o Do not allow products to overhang the front of the shelf as this could prevent the doors from shutting Leave an airspace of at least 50mm above product loaded on the top shelf Products must NOT be stored on the floor of the cabinet Do not exceed a maximum loading of 20kg per shelf Remove some product if the shelves are flexing or bending Do not move the cabinet when loaded with product Door Lock Each door has a key lock located at the top of the door on the same side as the handle FE OD Door Lock Installation 9 User Manual SKOPE Pegasus Vertical Series Remote Cabinet Installation The specifications below are specific to standard Pegasus Vertical Remote chillers and freezers Exceptions are possible due to model type installation type specification and or customised product SKOPE remote cabinets are also supplied with a seperate instruction sheet Guidelines for SKOPE remote Refrigeration PRN2362 Refer to this for generic SKOPE remote refrigeration installation guidelines Specifications Remote cabinets Type Chiller Freezer Refrig duty 1070 Waits Max ambient temp 40 C Mean product temp 18 C Condensing temp 45 C Evaporating temp 30 C Operation basis 18 24 hours 18 24 hours Optimised at 32 C 65 RH Electronic When the cabinet
17. wer supply for 1 minute then auto reset reconnect to power supply If alarm persists contact SKOPE NOTE The HI and LO alarms deactivate the cabinet lighting and trim heaters Refrigeration system 1 Clean the condenser coil See page 16 high temperature 2 Check refrigeration ventilation Ensure clear airpath at the pre warning auto reset top and front of the cabinet to extract hot air A minimum of 200mm clear space is required above and in front of the Refrigeration system Ene ato Al and cabinet high 3 Ensure the cabinet is installed in a suitable environment temperature shutdown 4 To reset the CHt alarm unplug the cabinet from the manual reset power supply for 1 minute then reconnect to power supply If alarm persists contact SKOPE Ambient probe fault also flashes rE Evaporator probe fault Condenser probe fault To reset alarm unplug the cabinet from the power supply for Defrost overtime limit 1 minute then reconnect to power supply 1 If alarm persists contact SKOPE Real time clock fault Controller E prom error Controller E prom error Start defrost request None End defrost request Check that a door or drawer has not been left open Note on Door open alarm p The audible alarm buzzer cannot be turned off manually Flashing wa O User Manual SKOPE Pegasus Vertical Series Ly Servicing Lighting Cabinet The cabinet interior is lit