Home
        RUGGEDCOM RS910
         Contents
1.   conducted  RFI A C power ports 10V   0  5 80 MHz 10V   0  5 80 MHz A  Earth ground ports 2 10V   0  5 80 MHz 10V   0  5 80 MHz A  IEC 61000 4 8 Magnetic field Enclosure ports 30 Alm c2 50  60 Hz 40 Alm continuous  1000 A m for1s A  30  for 0 5 period 30  for1 period B  IEC 61000 4 11 Voltage dips A C  power ports 100  for 5 periods    gt 95  for 250 periods a o      Signal ports 2k V AC  Fail safe relay output  2k V AC  Fail safe relay output  N A  IEC 60255 5 Dielectric strength D C  power ports ov DE LANA DE N A  A C  power ports 2k V AC 2k V AC N A  Signal ports 5kV  Fail safe relay output  5kV  Fail safe relay output  NIA  IEG 60255 5 H V  impulse D C  power ports 5kV 5kV N A  A C  power ports 5kV 5kV N A  IEC 60068 2 1 Cold temperature Test Ad  40  C  16 hours N A  IEC 60068 2 2 Dry heat Test Bd  85  C  16 hours N A  IEC 60068 2 30 Humidity  damp heat  cyclic  Test Db 95   non condensing   55  C   6 cycles N A  IEC 60255 21 1 Vibration Test Fc 2g    10   150  Hz Class 2    IEC 60255 21 2 Shock Test Ea 30g   11mS Class 2 1    1 Class 2 refers to    Measuring relays and protection equipment for which a very high security margin is required or where the vibration levels are  very high   e g  shipboard application and for severe transportation conditions         6 RUGGEDCOM RS910 2 port Serial Device Server With up to 3 Ports Managed Ethernet Switch  128 bit Encryption    Technical Specification    Power Supply   m Power consumption  10W max   m 24VDC  10 36VDC  0 4A   m 4
2.   terminals second  minimum 5 pulses per port test procedure  No physical damage   Electrical transients  One    1000VDC pulse every two EUT functioned properly following  Nondestruct transient seconds  3 per each polarity  test procedure  No physical damage   immunity  AC terminals     IEC 61850 3 EMI Type Tests    TS 2 1998  Section 2 para  2 2 8 4   Vibration endurance test    TS 2 1998  Section 2  para 2 1 10 Mechanical shock    Electrical transients   TS 2 1992  Section 2  para  2 1 6 1 High repetition noise   AC terminals     Electrical transients   TS 2 1998  Section 2 para  2 1 6 2 Low repetition high energy    TS 2 1998  Section 2  para 2 1 7    TS 2 1992  Section 2  para  2 1 8       Performance  Test Description Test Levels RuggedCom Test Level Criteria    IEC 61000 4 2 ESD Enclosure naa  l  4kV  l  8kV B  Enclosure air  l  8kV  l  15kV B  IEC 61000 4 3 Radiated RFI Enclosure ports 10 V m  80 to 1000Mhz 20V m A  T Signal ports     1kV   5kHz    4kV   2 5kHz B  IEC 61000 4 4 E D C  power ports  l  2kV   5kHz  l  4kV B  A C  power ports  l  2kV   5kHz  l  4kV B       l  2kV line to earth   Signal ports  l  1kV line to earth a eeliae B       l  4V line to earth   IEC 61000 4 5 Surge D C  power ports     0 5V line to earth line A e o nE B  ALG  Poner mare     2V line to earth   l  4V line to earth  B     1kV line to line  l  2kV line to line  Signal ports 10V   0  5 80 MHz 10V   0  5 80 MHz A  IEC 61000 4 6 Induced D C power ports 10V   0  5 80 MHz 10V   0  5 80 MHz A 
3.  300VDC or 85 264VAC  CSA UL 60950 safety approved to  85  C    m Screw connection terminal blocks ensure reliable  maintenance free connections    2 port Serial Device Server With up to 3 Ports Managed Ethernet Switch  128 bit Encryption       Operating  Temperature   gt   40  C to  85  C   gt  No fans    Fast Ethernet Ports    gt  Up to 3 Fast Ethernet Ports    gt  10 100BaseTX or 100BaseFX   gt  Multiple fiber connector types    j    OF  of  ome  AIE     a  Serial Ports      gt  2 RS485 RS422 RS232 ALARM   gt  DB9 or RJ45 I   gt     gt  Up to 230kbps RUGGEDCO    gt  Serial Fiber Interface Option RS910 vi    Critical Alarm Relay Mounting Options   gt  Form C failsafe contact relay   gt  DIN rail  1A 30VDC  gt  Panel mount    2 port Serial Device Server With up to 3 Ports Managed Ethernet Switch  128 bit Encryption       Hazardous Location  Compliance     gt  Class 1  Division 2    Rugged Construction   gt  20 AWG  galvanized  steel enclosure     gt  Conformal coating   optional     Integrated Power   Supply    gt  Universal high voltage  range   88 300V DC or  85 264VAC    gt  Popular low voltage  DC ranges   24VDC  10 36V DC    48VDC  36 72VDC     gt  Dual Isolated DC  power inputs    RUGGEDCOM RS910 3    ROS Features    Serial IP Encapsulation   Many    legacy    devices  RTU  PLC  IED  etc   only support  serial Communications via RS232  RS422 or RS485  ROS  encapsulates the serial data within a TCP connection  allowing these devices to be reached via an IP network   A w
4.  MIB    RUGGEDCOM RS910    Fiber Specifications and Dimension Drawings    Fiber Optical Specifications       Mode Multimode Singlemode Singlemode Singlemode  Connector MU Si SETHE EGws Gast Ge SCesii Me  SIG  ST   Typical dist   km  2 20 50 90   Optical wavelength  nm  1310 1310 1300 1300   Cable size core cladding  um  50  12561 62 5    125 Si 125 01 9 125 8  125 0797  25 Si 125 0797 125  TX power  min max   dBm   9 5    4  91 3  7 1 3 Ones   RX sensitivity  dBm   15 7  15 5  2 5  2 5   RX saturation  dBm   33 5  32  37  39   Typical budget  dB  17  ews  34 5 41 5    Longer segment lengths dependent on fiber specifications  Consult factory for further details     FAILSAFE    RESISTIVE FOR CLASS 2 CIRCUITS 0    CONTACTS RATED   OVDC 1A   30VAC 0 3A     8VDC 0 3A       Overall dimensions  All dimensions are in millimeters  unless otherwise stated     8 RUGGEDCOM RS910 2 port Serial Device Server With up to 3 Ports Managed Ethernet Switch  128 bit Encryption    Dimension Drawings      All w    y U0 Md    SSS Se    120 65       Panel and DIN rail mount dimensions    All dimensions are in millimeters  unless otherwise stated     2 port Serial Device Server With up to 3 Ports Managed Ethernet Switch  128 bit Encryption RUGGEDCOM RS910 9    Order Codes    6GK60910AT2       PM1  Power Module 1 E2  Ethernet Ports Options  1   24 VDC  10 36 VDC  COO   No port  2   48 VDC  36 72 VDC  C01   1 x 100BaseTX   RJ45 connector  3   87 264VAC or 88 300VDC CO2   1 x 100BaseFX   Multimode  MTRJ 
5. 8VDC  36 72VDC  0 2A   m HI voltage AC DC  88 300VDC  85 264VAC  0 1A    Critical Alarm Relay  m Form C failsafe contact relay   1A 30VDC    Physical Dimensions   Height  7 4     188mm    Width  2 6     66mm    Depth  5 0     127mm    Weight  2 7 Ibs   Ingress protection  IP40  1mm objects   Enclosure  20 AWG galvanized steel enclosure  Mounting  DIN rail or panel mounted    Switch Properties   Switching method  Store and forward  Switching latency  8 us  100Mbps   Switching bandwidth  1 8 Gbps   MAC address table size  16kbytes  Priority queues  4   Frame buffer memory  1 Mbit  Simultaneous VLANs  255   VLAN ID range  1 to 4094   IGMP and static multicast groups  256  Port rate limiting  128kbps  256  512  4  8Mbps  No head of line blocking    Regulatory Approvals   m ISO  Designed and manufactured using a ISO9001   2000 certified quality program   m CE marking   m Emissions  FCC Part 15  Class A   EN55022  CISPR22 Class A    m Safety  cCSAus  Compliant with CSA C22 2 No  60950   UL 60950  EN60950    m Laser eye safety  FDA CDRH   Complies with 21 CFR  Chapter 1  Subchapter J    Network Management   m HTTPS graphical web based  SSL  128 bit encryption    m SNMP v1  v2c  v3  56 bit encryption    m Telnet  VT100  SSH SFTP  128 bit encryption    m Command Line Interface  CLI    m RSA key management  1024 bit key    m Authentication and accounting     TACACS   encrypted    RADIUS client  PPP    Warranty  m 5 Years     Applicable to design and manufacturing related  product defec
6. alysis  and detection of traffic patterns     Event Logging and Alarms    ROS records all significant events to a non volatile system  log allowing forensic troubleshooting  Events include link  failure and recovery  unauthorized access  broadcast storm  detection  and self test diagnostics among others  Alarms  provide a snapshot of recent events that have yet to be  acknowledged by the network administrator  An external  hardware relay is de energized during the presence of critical  alarms allowing an external controller to react if desired     HTML Web Browser and Telnet SSH User  Interfaces    ROS provides a simple  intuitive user interface for configuration  and monitoring via a standard graphical web browser or via  Telnet SSH  All system parameters include detailed on line  help to make setup a breeze  ROS  presents a common look  and feel and standardized configuration process allowing  easy migration to other RUGGEDCOM managed products     Configuration Via ASCII Text File    All configuration parameters are stored in an ASCII formatted  text file that can easily be transferred via SFTP  TFTP  or  Xmodem  The configuration file can be saved for backup  purposes and easily manipulated by a text editor  The same  text file can be downloaded to the switch at a later date in  order to re configure or restore a previous configuration     Command Line Interface  CLI     A command line interface can be used in conjunction with  remote shell to automate data retrieval  conf
7. connector  C03   1 x 100BaseFX   Multimode  SC connector  Mount  Mounting Options C04   1 x 100BaseFX   Multimode  ST connector  A   No mounting option CO5   1 x 100BaseFX   Multimode  LC connector  B   DIN rail mounting C06   1 x 100BaseFX   Singlemode  ST connector  20km  C   Panel mounting C07   1 x 100BaseFX   Singlemode  LC connector  20km    C08   1 x 100BaseFX   Singlemode  LC connector  50km  C09   1 x 100BaseFX   Singlemode  LC connector  90km  C10   1 x 100BaseFX   Singlemode  SC connector  20km  C11   1 x 100BaseFX   Singlemode  SC connector  50km  S  Serial Port Options C12   1 x 100BaseFX   Singlemode  SC connector  90km  AOO   None   A01   RS232 422 485 DB9   A02   2 x RS232 422 485 RJ45   A03   2 x fiber 850nm ST    MOD  Hardware Modifications  O   None  1   Conformal coating    E1  Ethernet Ports Options   BOO   No Ethernet ports   BO1   2 x 10 100TX RJ45   BO2   2 x 10FL   Multimode  850 nm  ST connectors   BO3   2 x 100FX   Multimode  1300 nm  ST connectors   BO4   2 x 100FX   Multimode  1300 nm  SC connectors   BO5   2 x 100FX   Multimode  1300 nm  MTRJ connectors   BO6   2 x 100FX   Multi mode  1300nm  LC connectors   BO7   2 x 100FX   Singlemode  1300 nm  ST connectors  20km  BO8   2 x 100FX   Singlemode  1300 nm  SC connectors  20km  BO9   2 x 100FX   Singlemode  1300 nm  LC connectors  20km  B10   2 x 100FX   Singlemode  1300 nm  SC connectors  50km  B11   2 x 100FX   Singlemode  1300 nm  LC connectors  50km  B12   2 x 100FX   Singlemode  1300 nm  SC co
8. d secure network traffic  RADIUS centralized password management   SNMPv3 authentication and 56 bit encryption    Rugged Rated for Reliability in Harsh  Environments  m  Immunity to EMI and heavy electrical surges     Meets IEEE 1613  electrical utility substations      Exceeds IEEE 61850 3  electrical utility substations     2 RUGGEDCOM RS910      Exceeds IEC 61800 3  variable speed drive systems     Exceeds IEC 61000 6 2  generic industrial     Exceeds NEMA TS 2  traffic control equipment    m  40 to  85  C operating temperature  no fans    20 AWG galvanized steel enclosure    m DIN or panel mounting options provide secure  mechanical reliability    m HazLoc Class 1  Division 2    Rugged Operating System  ROS  Features    m  Simple plug and play operation   automatic learning   negotiation  and crossover detection    m MSTP  802 1Q   2005  formerly 802 15    RSTP  802 1D 2004  and Enhanced Rapid Spanning Tree   eRSTP  network fault recovery   lt 5ms    Quality of Service  802 1p  for real time traffic   VLAN  802 1Q  with double tagging and GVRP support  Link aggregation  802 3ad    IGMP snooping for multicast filtering   Port rate limiting and broadcast storm limiting   Port configuration  status  statistics  mirroring  security  SNTP time synchronization  client and server     Universal Power Supply Options  m Fully integrated power supply  no external adaptors     m Popular low voltage DC ranges  24VDC  10 36VDC  or  48VDC  36 72VDC     m Universal high voltage range  88
9. ecurity features and comprehensive  networking functions such as Enhanced Rapid Spanning   Tree  eRSTP   Port Rate Limiting  and a full array of intelligent  functionality for high network availability and manageability   Coupled with ruggedness and durability that is designed in  from the onset  the RS910 is ideal for creating mission critical   real time  control applications where high reliability and  availability is of paramount importance     All RUGGEDCOM products are backed by a five year warranty  and unsurpassed technical support        usa siemens com ruggedcom       Features and Benefits    Serial Device Server   Transmit serial data over an IP network   2 serial port interfaces   RS485 RS422 RS232  DB9 or RJ45 connectors     Serial fiber interface  ST  option   Support for Modbus TCP  DNP 3  TIN serial protocols   Baud rates up to 230 kbps   Raw socket mode allows conversion of any serial protocol  Point to point and multi point modes    Converts Modbus RTU to Modbus  Multiple Modbus  masters    m Converts DNP3 0 to DNP over UDP TCP    Ethernet Ports   m Integrated fully managed Ethernet switch   m Up to 3 fast Ethernet ports  copper and or fiber    m Supports many types of fiber  multimode  singlemode   m Multiple connector types  ST  MTRJ  LC  SC     Cyber Security Features   Multi level user passwords   SSH SSL SFTP  1 28 bit encryption    Enable disable ports  MAC based port security   Port based network access control  802 1x    VLAN  802 1Q  to segregate an
10. ents both STP and  RSTP to ensure interoperability with commercial switches  unlike other proprietary    ring    solutions     Quality of Service  IEEE 802 1p     Some networking applications such as real time control  or VoIP  voice over IP  require predictable arrival times for  Ethernet frames  Switches can introduce latency in times  of heavy network traffic due to the internal queues that  buffer frames and then transmit on a first come first serve  basis  ROS supports    Class of Service    in accordance with  IEEE 802 1p that allows time critical traffic to jump ahead  to the front of the queue thus minimizing latency and  reducing jitter to allow such demanding applications to  operate correctly  ROS allows priority classification by  port  tags  MAC address  and IP type of service  ToS   A  configurable    weighted fair queuing    algorithm controls  how frames are emptied from the queues     VLAN  IEEE 802 1Q     Virtual local area networks  VLAN  allow the segregation  of a physical network into separate logical networks with  independent broadcast domains  A measure of security is  provided since hosts can only access other hosts on the  same VLAN and traffic storms are isolated  ROS supports  802 1Q tagged Ethernet frames and VLAN trunks  Port  based classification allows legacy devices to be assigned  to the correct VLAN  GVRP support Is also provided to  simplify the configuration of the switches on the VLAN     Link Aggregation  802 3ad     The link aggregatio
11. es   MAC addresses  can communicate via that port   m 802 1x port based network access control     The ability  to lock down ports on a switch so that only authorized  clients can communicate via this port    m RADIUS     authentication service using MD5 hash and  providing centralized password management   m  SNMPv3   encrypted authentication access security and  data encryption  CBC DES with 56 bit encryption key    m Secure socket layer     Web based management using  SSL with data encryption  1 28 bit encryption key    m RSA     1024 bit key for key management and key exchange   m TACACS      Terminal Access Control and Accounting  Services  Client provides encrypted authentication  and authorization    4 RUGGEDCOM RS910    m Point to Point  PPP      using CHAP  MD5 Hash   authentication service    m SFTP     Secure File Transfer Protocol using SSH encryption    The ROS cyber security features are included to help address  the various industry specific security standards such as  NERC CIP  ISA S99  AGA 12  IEC 62443  ISO 17799 2005  and PCSRF SPP ICS     Enhanced Rapid Spanning Tree Protocol   eRSTP    RUGGEDCOM eRSTP allows the creation of fault tolerant  ring and mesh Ethernet networks that incorporate  redundant links that are    pruned    to prevent loops  eRSTP  yields worst case fault recovery 1 of 5ms times the    bridge  diameter    and allows rings of up to 160 switches  For  example  a ring of ten switches will have fault recovery  times under 50ms  eRSTP implem
12. i j ih  n t 4 is we muy f i   1  ah   i        li Yi        j    hA 1 a of k T  pel k aime   VA     er Bn A  a       F pr  PP a        Se  aa    a    Da TEA     Product Overview    The RUGGEDCOM RS910 from Siemens is a utility grade serial  device server with an integrated  fully managed  Ethernet  switch  designed to operate reliably in electrically harsh and  climatically demanding environments  The RS910 can be  configured with 2 serial ports  RS485 RS422 RS232  and or  up to 3 Ethernet ports  copper or fiber  and is able to  interconnect multiple types of intelligent electronic devices   IEDs  that have different methods of communications   Using the RS910 results in fewer connectivity devices  which  reduces overall system costs  and also extends the useful life  of existing legacy IEDs  which minimizes capital expenditure  for new equipment      Designed to operate reliably in harsh environments   the RS910 provides a high level of immunity to  electromagnetic interference and heavy electrical surges  typical of environments found in electric utility substations   curb side traffic control cabinets  and factory floors  An  operating temperature range of  40  C to  85  C coupled  with hazardous location compliance  optional conformal  coating and a galvanized steel enclosure  allows the RS910  to be placed in almost any location     F  fa Fa Wi r  i jgyeees  es ye Fag ak ke of  T U nik  ATT  i ie       The embedded Rugged Operating System  ROS  provides  advanced cyber s
13. ide range of baud rates  frame packetization options   and diagnostics allows any serial protocol to function   The RS910 has specific support for the following   serial protocols    m Raw socket serial encapsulation   m Modbus TCP  client and server   m DNP 3   m WIN and TIN   m Microlok    MODBUS TCP    The Modbus protocol is ubiquitous in the industrial control  and automation world  ROS converts Modbus RTU master   Slave serial data packets to Modbus TCP client server  packets for transmission over an IP network  This allows  communications to Modbus RTU slaves via Ethernet and  allows multiple masters to poll the same slave device     Cyber Security    Cyber security is an urgent issue in many industries where  advanced automation and communications networks play   a crucial role in mission critical applications and where high  reliability is of paramount importance  Key ROS features that  address security issues at the local area network   level include     m Passwords     Multi level user passwords secures switch  against unauthorized configuration    m SSH  SSL   Extends capability of password protection  to add 128 bit encryption of passwords and data as they  cross the network    m  Enable Disable ports     Capability to disable ports so  that traffic can not pass    m 802 1Q VLAN   Provides the ability to logically segregate  traffic between predefined ports on switches    m MAC based port security     The ability to secure ports  on a switch so only specific Devic
14. iguration  updates  and firmware upgrades  A powerful SQL like  capability allows expert users the ability to selectively retrieve  or manipulate any parameters the device has to offer     RUGGEDCOM RS910 5    EMI and Environmental Type Tests    NEMA TS 2 Requirements       Performance Criteria    Temperature    Low temperature Low voltage  Temperature    Low temperature High voltage  Temperature    High temperature High voltage  Temperature    High temperature Low voltage    lis 2 1993  Section  2 palaiz 2 7 5 89 0V AC    34  C    TS 2 1998  Section 2  para 2 2 7 4 135 0V AC    34  C EUT continued to function properly  during and following all temperature  and humidity testing     TS 2 1998  Section 2  para 2 2 7 5 135 0V AC     75  C    TS 2 1998  Section 2  para 2 2 7 6 89 0V AC     75  C    0 5g   30Hz for 1hr on all  three planes    EUT functioned properly following  test procedure  No physical damage      10g half sine wave for EUT functioned properly following  11msec on all three planes test procedure  No physical damage     One    300VDC pulse every other EUT functioned properly following  cycle once every 3 seconds across test procedure  No physical damage   360    of line cycle  2500W peak    One    600VDC pulse every second  EUT functioned properly following  randomly distributed across 360    test procedure  No physical damage    AC terminals  of line cycle  Ten pulses total    Electrical transients  I O One    300VDC pulse every EUT functioned properly following
15. n feature provides the ability to  aggregate several Ethernet ports into one logical link  port  trunk  with higher bandwidth  This provides an inexpensive  way to set up a high speed backbone to improve network  bandwidth  This feature is also known as    port trunking         port bundling        port teaming     and    Ethernet trunk        1 eRSTP fault recovery times may be approximated as follows   For 100 Mbps  fault recovery performance is  lt 5ms hop  For 1 000 Mbps  fault recovery performance is  lt 5ms hop   20ms    2 port Serial Device Server With up to 3 Ports Managed Ethernet Switch  128 bit Encryption    ROS Features    IGMP Snooping    ROS uses IGMP snooping  Internet Group Management  Protocol v1 amp v2  to intelligently forward or filter multicast traffic  streams  e g  MPEG video  to or from hosts on the network   This reduces the load on network trunks and prevents packets  from being received on hosts that are not involved  ROS has a  very powerful implementation of IGMP snooping that     m Can be enabled on a per VLAN basis    m Detects and filters all multicast streams regardless of  whether subscribers exist    m Supports    router less    operation by supporting an     active    mode    m Restores traffic streams immediately after an RSTP  topology change    SNMP  Simple Network Management Protocol   SNMP provides a standardized method for network  management stations the ability to interrogate devices from  different vendors  SNMPv3 in particular pro
16. nnectors  90km  B13   2 x 100FX   Singlemode  1300 nm  LC connectors  90km    Example Order Codes    6GK6091 0AT21 OBA0 Z A01 B04 C06    24VDC Power Supply  DIN Rail Mount  RS232 422 485 DB9   2 x 100FX   Multimode  1300 nm  SC connectors   1 x 100BaseFX   Singlemode  ST connector  20km    6GK6091 0AT22 0CA1 Z A03 B10 C12    48VDC Power Supply  Panel Mount  Conformal Coating   2 x Fiber 850nm ST  2 x 100FX   Singlemode  1300 nm   SC connectors  50km  1 x 100BaseFX   Singlemode    SC connector  90km    10 RUGGEDCOM RS910 2 port Serial Device Server With up to 3 Ports Managed Ethernet Switch  128 bit Encryption    Siemens Industry  Inc   5300 Triangle Parkway  Norcross  GA 30092    1 800 241 4453  info us siemens com    usa siemens com ruggedcom    Subject to change without prior notice   All rights reserved     2015 Siemens Industry  Inc     The information provided in this brochure contains descriptions or  characteristics of performance which in case of actual use do not  always apply as described or which may change as a result of  further development of the products  An obligation to provide   the respective characteristics shall only exist if expressly agreed in  the terms of contract  Availability and technical specifications are  subject to change without notice    All product designations may be trademarks or product names   of Siemens AG or supplier companies whose use by third parties  for their own purposes could violate the rights of the owners        
17. orts configurable rate limiting per port to limit  unicast and multicast traffic  This can be essential to managing  precious network bandwidth for service providers  It also  provides edge security for denial of service  DoS  attacks     2 port Serial Device Server With up to 3 Ports Managed Ethernet Switch  128 bit Encryption    Broadcast Storm Filtering    Broadcast storms wreak havoc on a network and can cause  attached devices to malfunction  This could be disastrous on  a network with mission critical equipment  ROS limits this by  filtering broadcast frames with a user defined threshold     Port Mirroring    ROS can be configured to duplicate all traffic on one port   to a designated mirror port  When combined with a network  analyzer  this can be a powerful troubleshooting tool  Port   Configuration and Status ROS allows individual ports to be     hard    configured for speed  duplex  auto negotiation  flow  control and more  This allows proper connection with devices  that do not negotiate or have unusual settings  Detailed   status of ports with alarm and SNMP trap on link problems  aid greatly in system troubleshooting     Port Statistics and RMON  Remote Monitoring     ROS provides continuously updating statistics per port that  provide both ingress and egress packet and byte counters as  well as detailed error figures  Also provided is full support  for the RMON statistics  history  alarms  and event groups   RMON allows for very sophisticated data collection  an
18. ts    2 port Serial Device Server With up to 3 Ports Managed Ethernet Switch  128 bit Encryption    EMI Immunity and Environmental Compliance  m IEC 61000 6 2 Industrial  Generic    m IEC 61800 3 Industrial  Variable Speed Drive Systems   m IEC 61850 3 Electric Utility Substations   m IEEE 1613 Electric Utility Substations   m NEMA TS 2 Traffic Control Equipment   m Hazardous Locations  Class 1  Division 2    IEEE Compliance   m 802 3 10Basel   m 802 3u 100BaseTX  100BaseFX   m 802 3x Flow Control   m 802 3z 1000BaseLX   m 802 3ab 1000BaseTX   m 802 3ad Link Aggregation   m 802 1D MAC Bridges   m 802 1D Spanning Tree Protocol   m 802 1p Class of Service   m 802 1Q VLAN Tagging   m 802 1D 2004 Rapid Spanning Tree Protocol  m 802 1x Port Based Network Access Control  m 802 1Q 2005  formerly 802 1s  MSTP    IETF RFC Compliance   m RFC768 UDP   m RFC 83 TFIP   m RFC7 91 IP   m RFC 92 ICMP   m RFC793 TCP   m RFC826 ARP   m RFC854 Telnet   m RFC894 IP over Ethernet  m RFC1112 IGMP v1   m RFC1519 CIDR   m RFC1541 DHCP  client   m RFC2030 SNTP   m RFC2068 HTTP   m RFC2236 IGMP v2   m RFC2284 EAP   m RFC2475 Differentiated Services  m RFC2865 RADIUS   m RFC3414 SNMPv3 USM  m RFC3415 SNMPv3 VACM    IETF SNMP MIBS   m RFC1493 BRIDGE MIB   m RFC1907 SNMPv2 MIB   m RFC2012 TCP MIB   m RFC2013 UDP MIB   m RFC2578 SNMPv2 SMI   E RFC2579 SNMPv2 TC   m RFC2819 RMON MIB   E RFC2863 IF MIB   m draft ietf bridge rstpmib 03 BRIDGE MIB  m draft ietf bridge bridgemib smiv2 03 RSTP MIB  m IANAifType
19. vides security  features such as authentication  privacy with data encryption   CBC DES with 56 bit encryption key  and access control not  present in earlier SNMP versions  ROS also supports numerous  standard MIBs  Management Information Base  allowing   for easy integration with any network management system   NMS   A feature of SNMP supported by ROS is the ability   to generate    traps    upon system events  RUGGEDCOM NMS   the RUGGEDCOM management solution  can record traps  from multiple devices providing a powerful network trouble   shooting tool  It also provides a graphical visualization of the  network and is fully integrated with all RUGGEDCOM products     SCADA and Industrial Automation    ROS contains features that optimize network performance  and simplify switch management based on the unique  requirements found in SCADA and industrial automation  applications  Features such as Modbus TCP management  for retrieval of switch data using the ubiquitous Modbus  protocol and DHCP Option 82  a Rockwell Automation ODVA  requirement for IP address assignment based on the location  of the end device  provide capabilities not found in typical     commercial    or    office grade    Ethernet switches     Port Based Network Access Control  802 1x     ROS supports the IEEE 802 1x standard that defines a  mechanism for port based network access control which  provides a means of authenticating and authorizing  devices attached to LAN ports     Port Rate Limiting    ROS supp
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Un article sur le plagiat (Télérama n°3219 du 21 septembre 2011)  Barrier movement operator having service reminders  USER MANUAL FOR BATCH FED INDEPENDENT  Wentronic 2.5 - 3.5 Harddisk mounting set  Sommaire par Leçon / Mode d`emploi Cliquez ici pour télécharger le  321 Studios Enforcer SA-026 User's Manual    Copyright © All rights reserved. 