Home
RS900 Family Installation Guide
Contents
1. RS900 Series Family of Switches Installation Guide www ruggedcom com Copyright This document contains proprietary information which is protected by copyright No part of this document may be photocopied reproduced or translated to another language without the prior written consent of RuggedCom Inc Disclaimer RuggedCom has checked the contents of this manual against the hardware and software described However deviations from the description cannot be completely ruled out RuggedCom shall not be liable for any errors or omissions contained herein or for consequential damages in connection with the furnishing performance or use of this material The information given in this document is reviewed regularly and any corrections will be included in subsequent editions RuggedCom reserves the right to revise this document or withdraw it at any time without prior notice FCC Radio Frequency Interference Statement This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely
2. 22 Table 5 Typical Performance on 24 AWG PIC twisted pair with Universal EoVDSL ports 23 Table 6 Typical Performance on 24 AWG PIC twisted pair with Long Reach EoVDSL ports 23 Eel 7 A ansam M 25 Table S RJ45 port LED descriptio o eco esee eese x eei que o e Neo ea Ene Tue EU Ev TOUR EE Yee a aae e osque PvE talado 25 Table9 DB9 Female DCE Port int ees eere reu ica 28 Table TOR 4d Fort pOr iii iii 29 Table 11 Operating Dui 33 Table 12 Power Supply Specifications iii its 33 Table 13 Failsafe Relay Specification eeeeeecocccsssssssscececcococoocsossscescececocccssssssececcccccoccsosssssssscececeeeesssss 33 Table 14 Failsafe Relay Isolation esececceeccoocosssssssecccccecoccccssossssssececcocecccsosssssseccccccceoccsssssssssccececeeessssss 34 Table 15 RJ11 Ethernet over VDSL Port Specifications ssssssesccececccccosssssccececcccoccsosssssssecececeesosssso 34 Table 16 RJ45 Ethernet Port SpecificationS sseccceeccccccssssssseccccccocccccccssssssscecececcocososssssssecececeeeosssso 34 Table 17 Fiber Optic Port Specifications ccccrcccsssssssesssssssoccccccccevccssseesessssoossccsccnscessesssseeeesssssosossces 35 Table 18 Communication Standard Compliance ccccccccssssssssssssssssssscscscccccccccccccccscsssssssssssccscsesooes 36 Table I9 Wireless Standards Supported isis v eee eene tu ee e
3. RJ11 Ethernet over VDSL Port Specifications 6 4 2 RJ45 Ethernet Port Specifications 10 100 Mbps CAT 5 UTP or STP RJ45 Table 16 RJ45 Ethernet Port Specifications Page 34 of 42 2008 RuggedCom Inc All rights reserved Rev100 RS900 Family Installation Guide 6 4 3 Fiber Optic Ethernet Port Specifications 100FX MM MTRJ 1300 50 125 22 5 14 62 5 125 19 14 MM SC 1300 50 125 22 5 62 5 125 1 1300 50 125 22 5 62 5 125 1310 62 5 125 1310 9 125 1300 9 125 1300 9 125 O n2 O Rh C2 C I 4 I 4 co e E gt co LN E RUN oo oo N P KR BR KR BR KR BR 5 14 9 14 5 14 14 gt nm i m O al Table 17 Fiber Optic Port Specifications NOTES 1 All values listed are average values 2 To convert from average to peak add 3 dBm To convert from peak to average subtract 3 dBm 3 Maximum segment length is greatly dependent on factors such as fiber quality and number of patches and splices Please consult RuggedCom sales associates when determining maximum segment distances 1 1 1 9 9 5 5 5 O Rh oo Y oo Y Page 35 of 42 O 2008 RuggedCom Inc All rights reserved Rev100 RS900 Family Installation Guide 6 4 4 Communication Standards Ethernet IEEE 802 3 VDSL ETSI TS 101 270 2 V1 1 1 ITU T G 993 1 ANSI T1E1 4 Table 18 Communication Standard Compliance Page 36 of 42 2008 RuggedCom Inc All rights reserved Rev100 RS900 F
4. 7Z4 Hollywood Florida 33020 Aztec West Almondsbury Bristol Canada USA BS32 4TD United Kingdom Toll Free 888 264 0006 Toll Free 866 922 7975 Tel 44 1454 203 404 Tel 905 856 5288 Tel 954 922 7975 Fax 44 1454 203 403 Fax 905 856 1995 Fax 954 922 7984 Technical Support North America 954 922 7975 North America Toll Free 866 922 7975 International 1 905 856 5288 Email support 9ruggedcom com Table of Contents 1 PIO COI said 6 1 1 Tuncitonal OVerviIe Wenden AS 6 1 2 TUG CCAS MC ctu ds io D Ret caes OE 7 1 3 hnugvedMarelessdPamily ob FLOQUECTS cutem td tp co ideni n ENS 8 1 4 R ced VDSLT amily Of PYOdUOls A A qe ts oie A bo s toan taste p qti c Uca dean 10 1 5 PRU OCS VERA TE T TT EE 42 1 6 Front Fanell Desci PON sentes it Yd Une UR Si AGAR 13 I7 Bottom Fanell Descrip otisses eee A cr de AE EAT E AS 14 Jai MP E E 15 Zl Din ARGU MO o eee 15 2 2 Power Supply Wiring and Groundin arcieri i itt hme deii e d 16 2 3 5232 CONSOLE POL WAITS sei c et i ENTRE tune eee EN EUR ERN eR EA E CEN Ee dpt E CEPERUNT 20 sigo cmm 21 3 1 RIIE Eemer over VOSOTRAS denn 21 3 2 R AS ECN RI ed ree caes 23 iU EIEDERO PRE EIhe rhet POPE s Ms oat dee iac set eet dea Meat Mes urea 26 3 4 Wireless EXhe He TONG ii A reset cats AA Cs abeste estesa Edu duse 27 Seral FORS cherien eeraa e ge A A gee AU eum Decca E EA 28 4 1 DBD SCHALLER OV EEE iaa 28 4 2 y P EET E ae a EEE AE E A EAE E AEE E E AAT 29 4 3 FADO IS EN OLL OV EEE
5. Pe Pee eU een eee vago ae epP eV E etes EP e eee ea eese dua 37 Table 20 2 Radio Characteristics eee diee ico L a ces rete Ce ee da op aa Na E rE 02022 009c EoiN 37 Table 21 Channel allocations for IEEE 802 1 15b g eere e eee eee e ee eere eee ee ee eese e eee e eeu 38 Table 22 Copper Port Speci Cav Os siii PE NP Ure Le baa e oepe EE NEUE EE EUN casducseseseenccesaevesbecseceaveasooses 39 Table 23 Fiber Optic Port Specification ee eeee eere ee e eorr reete eere eere e e eoe eee e epe P eaae ee eee eee e eee eee e Poo 39 Table 24 Mechanical Specifications 2 25 0 02120050970 dd IL iceis 40 Maple 25 EH SX M Type rire cesia 41 iri 26 2 TEE 1613 Type CSUs crc 42 Table 27 Environmental Type Tesis acces tiessussecucceascsewenseasoecceseieueesseoess 42 Page 5 of 42 2008 RuggedCom Inc All rights reserved Rev100 RS900 Family Installation Guide 1 Product Overview 1 1 Functional Overview The RS900 family of switches are environmentally hardened fully managed switches supporting a variety of Ethernet interfaces including copper fiber wireless as well as Serial communications The RS900 family s superior ruggedized design coupled with the RuggedSwitch Operating System ROS provides improved system reliability and advanced networking features making it ideally suited for creating Ethernet networks for missio
6. connected to the common wire inside the shield The shield should be connected to earth ground at a single point to avoid loop currents 6 The twisted pair should be terminated at each end of the chain e The figure below shows the recommended RS485 wiring Negative Common Isolated Termination Connect the 1200hm 10nF shield to earth ground at a single point lt 32 RS485 4000ft Devices ds E ra xs ene X S Soa MONIS UN hs a Termination 120ohm 10nF m ND EN ees R5485 Device E TD E m i m E TENE d ur v Figure 18 Conceptual recommended RS485 wiring diagram Page 31 of 42 2008 RuggedCom Inc All rights reserved Rev100 RS900 Family Installation Guide 5 Transient Protection RuggedCom does not recommend the use of copper cabling of any length for critical real time substation automation applications However transient suppression circuitry is present on all copper ports to protect against damage from electrical transients and to ensure IEC 61850 3 and IEEE 1613 Class 1 conformance This means that during the transient event communications errors or interruptions may occur but recovery is automatic RuggedCom also does not recommended to use these ports to interface to field devices across distances which could produce high levels of ground potential rise i e greater than 2500V during line to ground fault conditions Page 32 of 42 2008 RuggedCom Inc All right
7. figure below shows the shows the RJ45 port pin out and LEDs S 76564327 Figure 10 RJ45 port pin out and LEDs 7 Case Shield Chassis Ground Table 7 RJ45 port pin out 10 Mbps ides 100 Mbps Link Established Tf Acti Table 8 RJ45 port LED description Page 25 of 42 2008 RuggedCom Inc All rights reserved Rev100 RS900 Family Installation Guide 3 3 Fiber Optic Ethernet Port Depending on the order code of the product the unit can be equipped with several different fiber optic ports The Transmit Tx and Receive Rx connections of each port must be properly connected and matched for proper link and operation The drawings in the following figures show each fiber optical connector style with a side and top view to allow the user to identify the proper cable connection orientation Figure 12 100FX ST connector lele Figure 13 100FX SC connector Figure 14 100FX LC connector Page 26 of 42 2008 RuggedCom Inc All rights reserved Rev100 RS900 Family Installation Guide 3 4 Wireless Ethernet Port Refer to the RuggedCom Wireless Guide for an introduction to 802 11 Ethernet based wireless technologies as well as answers to frequently asked questions Refer to the Rugged Operating System ROS User Guide for instructions on wireless port configuration Both of the above documents can be downloaded from the following webpage http www ruggedcom com products ruggedwirel
8. to cause harmful interference in which case the user will be required to correct the interference at his expense Caution This product contains a laser system and is classified as a CLASS 1 LASER PRODUCT Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure Important This product contains no user serviceable parts Attempted service by unauthorized personnel shall render all warranties null and void This unit should be installed in a restricted access location where access can only be gained by service personnel or users who have been instructed about the reasons for the restrictions applied to the location and about any precautions that shall be taken and access is through the use of a tool or lock and key or other means of security and is controlled by the authority responsible for the location Trademarks Ethernet is a trademark of Xerox Corporation RuggedSwitch RuggedRated ROS and eRSTP are trademarks of RuggedCom Inc Warranty RuggedCom warrants to Purchaser that Products are free from defects in material and workmanship for five 5 years after shipment For warranty details visit http www ruggedcom com or contact your customer service representative Contacting RuggedCom Corporate Headquarters US Corporate Headquarters European Headquarters 30 Whitmore Road 1930 Harrison St Suite 307 Unit 41 Aztec Centre Woodbridge Ontario L4L
9. twisted pair the following performance is typical with Universal EoVDSL ports Table 5 Typical Performance on 24 AWG PIC twisted pair with Universal EoVDSL ports The following performance is typical with Long Reach EoVDSL ports 3300 105 0 18 Table 6 Typical Performance on 24 AWG PIC twisted pair with Long Reach EoVDSL ports 6600 a D 10 Page 23 of 42 2008 RuggedCom Inc All rights reserved Rev100 RS900 Family Installation Guide NOTES 1 The EoVDSL ports are designed to be used on private communications lines for point to point connections and are not to be connected to the Public Switched Telephone Network PSTN 2 To reduce the risk of fire use only No 26 AWG or larger telecommunication line cord 3 In Manual Mode assuming the distance can support the speed setting the time to port up is typically 15 30 seconds Page 24 of 42 2008 RuggedCom Inc All rights reserved Rev100 RS900 Family Installation Guide 3 2 RJ45 Ethernet Port Units with 10 100Base TX ports allow connection to standard Category 5 CAT 5 unshielded twisted pair UTP cable with RJ45 male connectors The RJ45 receptacles are directly connected to the chassis ground on the unit and can accept CAT 5 shielded twisted pair STP cables If shielded cables are used care must be taken to ensure the shielded cables do not form a ground loop via the shield wire and the RJ45 receptacles at either end The
10. 000 4 5 Sige 2kV a 1kV line to 4kV nM 2kV line to ine 10V Ec 61000 46 Iced 1 Conducted RFI 10V 10V 40 A m continuous 1000 A m for 1 s 30 for 0 18 60 for 0 1s 100 for IEC 61000 4 29 Voltage Dips amp 0 05s Interrupts 30 for 1 period 60 for 50 periods A C Power ports 100 for 5 periods 100 for 50 periods 2 5kV common 1kV differential mode 1MHz Damped 2 5kV common 1kV differential mode 2 5kV common 1kV differential mode Q 1MHz IEC 61000 4 16 Mains Frequency Signal ports 30V Continuous 300V for 1s Voltage D C Power ports 30V Continuous 300V for 1s IEC 61000 4 17 Ripple on D C D C Power ports 10 Power Suppl Signal ports 2kV AC Fail Safe Relay output IEC 60255 5 Dielectric Strength D C Power ports 2kV AC A C Power ports 2kV AC Signal ports 5kV Fail Safe Relay output IEC 60255 5 H V Impulse D C Power ports A C Power ports 5kV 5kV Table 25 IEC 61850 3 Type Tests NA NA O NA NA NA NA Page 41 of 42 2008 RuggedCom Inc All rights reserved Rev100 RS900 Family Installation Guide 7 2 IEEE 1613 Type Tests C37 90 3 ESD Enclosure Contact Enclosure Air C37 90 2 Radiated RFI Enclosure ports Signal ports D C Power ports A C Power ports Earth ground ports 2 5kV common mode 1MHz 2 5kV common 4 differential mode 1MHz Signal ports 7 Oscillatory D C Power ports A C Power ports 2 5kV common amp differential mo
11. E A EEEE ETE EE ated cca ETE EEEE 30 4 4 KSAS WIN O er EEN 31 TEOBSIEDE o 32 Technical SPECIICAIONS eq ada a RE Tito de m Reto ved a a aa em ae 33 6 1 Operating ENVIE E sss NE cda ue OR 33 6 2 POWER Supp SDeCUCUltONns A AA els en AA adsum emt eed eel Mead 929 6 3 Fausale Relay SPCCHIC QU ONS iii ue UOS Ru ad ouod ud es Pe Reate ndn 33 6 4 Ethernet Ports SPECIIUCAUONS vau e s tete Deis ane wea uaa en usa omen de uite ea NUS 34 6 5 Wireless Ethernet Port Speci CQ ion e ir etta EE ECCE E cree e E eU eae 37 6 6 VEIL Pofts SPECICATION tala iaa dias 39 6 7 Mechanical Specification S lt lt D EDU ari as RE 40 O E 41 7 1 pA GH Oo ate Oo ae Mayo cad RAY SARA ES Ce coda tumet eue eu A 41 RS900 Family Installation Guide 2 TEE RB LORS TYPE CSU cick cet hii te ce NOU DL NN Oates al a std Ne EL UE 42 Les TEC REnytronmental NDC TOSISsce estu p dete Oso tee D A I Det place ooi se tee mmt ME UII a 42 Page 4 of 42 2008 RuggedCom Inc All rights reserved Rev100 RS900 Family Installation Guide Table of Figures pEieure Et Front Panel D SceEIDION eiie cas 13 Figure 2 bottom Panel Descrip eot os 14 Figure 5 DEN Rail MOUDBLUNPMD ostiis eae rase do Seo AREA nane Sea oko seek RUI QVO CANON Aaa cla EIER DEVE CREARE dS 15 Figure 4 POWer Supply IBDULS aiii retra eoe Pero sop ba a EEE EEEE EE EEE T 16 Figure 5 DC Power supply wiring and grounding diagram cc ccce ecce eere eere eerte etn 17 Exreure P
12. EEE 802 1X RADIUS using EAP PEAP for secure enterprise class authentication e Pre shared Key Mode PSK for personal mode authentication configuration RS900W Wireless Ethernet with integrated 8 Port Switch e 1 Wireless interface e Up to 8 fast Ethernet ports e Copper and fiber options RS910W Wireless Serial Device Server with 2 Serial and or 2 Ethernet Ports e 1 Wireless interface e 2RS485 RS422 R 232 Serial ports DB9 or RJ45 Serial Fiber interface ST available e 2 Optional Ethernet ports lt Port 9 4 Power amp iba Fes Antenna 1 IR Antenna 1 Ports 3 amp 4 Bi 10 100Base TX 802 11b g or Ports 7 amp 8 100Base FX 10 100Base TX Or 100Base FX Ports 1 4 2 Serial Ports 1 6 10 100Base TX Foe Alarm lt Port 9 Port 9 Antenna 2 Antenna 2 Page 8 of 42 2008 RuggedCom Inc All rights reserved Fev100 RS900 Family Installation Guide RS920W Wireless Serial Device Server with 2 Serial Ports and 1 Ethernet over VDSL Interface e 1 Wireless interface e 1 EoVDSL interface e 2 RS5485 RS422 RS232 Serial ports DB9 or RJ45 Serial Fiber interface ST available Port 9 Antenna 1 Port 7 Ethernet over VDSL Ports 1 amp 2 Serial Power amp Alarm RS930W Wireless Ethernet with Integrated 6 Port Switch and 1 Ethernet over VDSL Interface e 1 Wireless interface e 1EoVDSL interface e 6 fast Ethernet ports Power amp Alarm Po
13. M NOTES e Mexico is included in the Rest of World regulatory domain however channels 1 through 8 are for indoor use only while channels 9 through 11 can be used indoors and outdoors Users are responsible for ensuring that the channel set configuration complies with the regulatory standards of Mexico e n Japan channel 14 is not supported for 802 11g mode Page 38 of 42 2008 RuggedCom Inc All rights reserved Rev100 RS900 Family Installation Guide 6 6 Serial Ports Specifications 6 6 1 DB9 amp RJ45 Serial Port Specifications Table 22 Copper Port Specification 6 6 2 Fiber Serial Port Specifications Optical Wavelength n 80 Cable Size 50 125 Core Cladding um 62 5 125 Table 23 Fiber Optic Port Specification Page 39 of 42 2008 RuggedCom Inc All rights reserved Rev100 RS900 Family Installation Guide 6 7 Mechanical Specifications 16 8 x 11 7 x 6 6 cm 6 6 x 4 6 x 2 6 inches Weight 1 2 kg 2 7 lbs 20 AWG Galvanized Steel Table 24 Mechanical Specifications 3428 INNO MENTA SUMA ABUNDAR Tna 304 03A0M3y3 1340488 Wra8 HI0 Figure 19 Mechanical Specifications Page 40 of 42 O 2008 RuggedCom Inc All rights reserved Rev100 RS900 Family Installation Guide 7 Type Tests 7 1 IEC 61850 3 Type Tests 15kV 20 Vim 4kV 2 5kHz eceroooas Burt Fast A Transient l AkV Ak 4kV line to earth 2kV line to line EC 61
14. amily Installation Guide 6 5 Wireless Ethernet Port Specification 6 5 1 Wireless Standards Supported IEEE 802 11b Backwards compatibility IEEE 802 11i Robust Secure Network RSN Enhanced Encryption WPA TKIP RC4 Temporal keys Basic Encryption WEP RC4 Up to 4 static keys IEEE 802 1x Wireless Authentication Personal or Enterprise PSK or RADIUS Table 19 Wireless Standards Supported 6 5 2 Radio Characteristics Modulation Direct Sequence Spread Spectrum 802 11b OFDM 802 119 6 54 Mbps OFDM 11 Mbps CCK Data Rate 5 5 Mbps CCK 2 Mbps DQPSK 1 Mbps DBPSK 11 US FCC 11 CAN IC Channels 14 Japan MKK 13 Other countries ETS 100 mW 20dBm 802 11b 11Mbps Data Rate 100 mW 20dBm 802 11g 6 24Mbps Data Rate Output Power 79 mW 19dBm 802 119 36Mbps Data Rate 63 mW 18dBm 802 119 48Mbps Data Rate 40 mW 16dBm 802 119 54Mbps Data Rate e At Radio 802 11b 11Mb 88dBm With Antenna 11Mb Q 91dBm Receiver Sensitivity At Radio 802 119 54Mb Q 74dBm With Antenna 54Mb Q 77dBm Table 20 Radio Characteristics Page 37 of 42 2008 RuggedCom Inc All rights reserved Rev100 RS900 Family Installation Guide 6 5 3 Channel Allocations for IEEE 802 11b g The channel identifiers channel center frequencies and regulatory domains of each IEEE 802 11b g 22 MHz wide channel are shown in the table below Ed 2412 Table 21 Channel allocations for IEEE 802 11b g ot po o 8 o9 p
15. ausate Output Relay caidas a P PCS ERE DURAS 18 Lionr 7 lt Dielectric Strength eMac ec eee 19 Ereure s R52352 Female DEEP OU dust ioo Dut ioo eee ue ve E dopo i beu eP o Q0 Du Cl cono e aaa 20 Pisure 9 RIH port pin out and LEDS inii cosas sae chs eee dees ech pea asec eet 22 Fieur 10 RJ45 port pin out and LEDs iih reo reo Einb pee 120000200 ee ed dedic ee esc 25 Figure 11 100FX MTRJ connector 5 1 121 2222 20292222220222222220122 2202 2220208925222 52222 0002252209 22 000 052020 26 Fisure 12 I00E X ST connector 2 isi ha noo 00 nope DOE eaa A A 26 Figure 13 100E X SC COBDOCIOE eene ha nno Da nope DOb aaa A pennas 26 Figure 14 MIL ME eren iuro 26 Figure 15 DB9 Female DCE Port pin out 5 1202s egeo Ha eaae go Erga ce pua Dea ee RR Rs aa aene ao Saone ob Adan ape rendida 28 Fiseurc I6 R45 Port DIn oUft ui tdt 29 Figure 17 Fiber Serial Interface ST Connector eee eee e eee eere reete eerte teet ettet ette tete eetessos 30 Figure 18 Conceptual recommended RS485 wiring diagram ccce eee e ecce eere eere eere etn 3l Figure I9 MechanicaL SDpeciHICatigHs iiio cerei ide oed soia teo PES ke ao Soap ado inician osado ae dose P dea o eo Dena Reus 40 Table of Tables Table L Statuas yp tas 13 Table 2 R5252 Female DC E TM dae 20 Table Se RILL port DIB OUL eorr ee Ta 22 Table 4 RJ11 port LED ESCUDO e eva Ue eee laevo A ave aate Ue uae ve eee vd e ee eene ever ow
16. de 1MHz 8kV 15kV 35 V m 4kV Q 2 5kHz 4kV 4kV 4kV Fast Transient C37 90 1 C37 90 1 C37 90 C37 90 Table 26 IEEE 1613 Type Tests Signal ports 5 kV Failsafe Relay H V Impulse D C Power ports 5 kV A C Power ports 5 kV Signal ports 2kV AC Failsafe Relay D C Power ports 2kV AC A C Power ports 2kV AC NOTE e Ifthe unit contains copper ports the IEEE 1613 conformance is Class 1 During disturbance errors may occur but recovery is automatic e If the unit contains all fiber ports the IEEE 1613 conformance is Class 2 During disturbance no errors will occur 7 3 IEC Environmental Type Tests IEC 60068 2 1 Cold Temperature 40 deg C 16 Hours IEC 60068 2 30 neal 95 non condensing 55 C 6 cycles Table 27 Environmental Type Tests Page 42 of 42 2008 RuggedCom Inc All rights reserved Rev100
17. e pins are permanently asserted to 5V so that DTE devices that require DCD DTR or CTS signals will operate However hardware flow control via RTS is not recognized 3 The Common terminals are optically isolated however there is transient voltage protection circuitry between the Common terminals and chassis ground Page 29 of 42 2008 RuggedCom Inc All rights reserved Rev100 RS900 Family Installation Guide 4 3 Fiber Serial Port The Fiber Serial Interface ST connector only which allows RS485 RS422 or RS232 devices to communicate over secure noise immune optically isolated fiber optic cabling at extended distances as well as protocol independent conversion to multimode fiber optics Figure 17 Fiber Serial Interface ST Connector Page 30 of 42 2008 RuggedCom Inc All rights reserved Rev100 RS900 Family Installation Guide 4 4 RS485 Wiring Each RS485 port can communicate to multiple RS485 devices by daisy chaining devices over a single twisted pair with transmit and receive signals on the same two wires half duplex The following guidelines should be followed to ensure reliable continuous communication 1 To minimize the effects of ambient electrical noise shielded cabling is recommended The correct polarity must be observed throughout a single daisy chain 3 The number of devices wired should not exceed 32 and total distance should be less than 4000 feet at 100 kbps 4 The Common terminals should be
18. er interface ST available RuggedVDSL Y RS920L Port 9 Ethernet over VDSL Port 3 Ethernet over VDSL Ports 1 amp 2 Jl Serial gt Power amp Alarm O 2008 RuggedCom Inc All rights reserved RS930L Dual Ethernet over VDSL interfaces with Integrated 6 Port Switch e 2EoVDSL interfaces e 6 fast Ethernet ports RuggedVDSL RS930L Power amp Alam gt O Alarm O Ethernet Port 7 over VDSL Ethernet over VDSL Ports 1 6 10 100Base TX Page 11 of 42 Rev100 RS900 Family Installation Guide 1 5 RuggedServer RS910 2 Port Serial Device Server with up to 3 Ethernet Ports e 2 R5485 RS422 RS232 Serial ports DB9 or RJ45 Serial Fiber interface ST available e Up to 3 fast Ethernet ports e Copper and fiber options RuggedS RS91 E Port 9 Ports 3 amp 4 10 100Base TX 10 100Base TX s or O o 100Base Fx 100Base FX a Ports 1 amp 2 Serial Power 4 Alarm e UGGEDCOM Page 12 of 42 2008 RuggedCom Inc All rights reserved Rev100 RS900 Family Installation Guide 1 6 Front Panel Description RuggedSwltch RS900 Power Alarm O Power i amp Reset O Alarm Port 9 O Reset 10 100Base TX lt or Ports 3 amp 4 FARM e 100Base Fx 10 100Base TX or 100Base FX Ports 1 6 10 100Base TX Figure 1 Front Panel Description Power LED AlamLED Red Solid Alarm condition exists Table 1 Status LEDs Page 13
19. ess rs900w Page 27 of 42 2008 RuggedCom Inc All rights reserved Rev100 RS900 Family Installation Guide 4 Serial Ports Serial ports can be either DB9 Serial ports RJ45 serial ports or Fiber Serial ports 4 1 DB9 Serial Port The DB9 port is selectable via software to be RS232 RS485 or RS422 Common Isolated Ground CTS ATS AL RA RI No Connection Shield Table 9 DB9 Female DCE Port pin out NOTES 1 No internal termination is provided 2 Pins 1 4 and 6 are connected internally Pins 7 and 8 are connected internally The pins are permanently asserted to 5V so that DTE devices that require DCD DTR or CTS signals will operate However hardware flow control via RTS is not recognized 3 The Common terminals are optically isolated however there is transient voltage protection circuitry between the Common terminals and chassis ground Page 28 of 42 2008 RuggedCom Inc All rights reserved Rev100 RS900 Family Installation Guide 4 2 RJ45 Serial Port The RJ45 Serial port is selectable via software to be RS232 RS485 or RS422 87654321 Figure 16 RJ45 Port pin out J J C W 8 JJ J JJ Common Isolated Ground RX RX TX TX RX TX crs RTS TXIRX TX Chassis Ground 6 2 8 Shield Shield Table 10 RJ45 Port pin out NOTES 1 No internal termination is provided 2 Pins 1 2 and 3 are connected internally Pins 7 and 8 are connected internally Th
20. g to the applicable country wiring codes 2 Allline to ground transient energy is shunted to the Surge Ground terminal In cases where users require the inputs to be isolated from ground remove the ground braid between Surge and Chassis Ground Note that all line to ground transient protection circuitry will be disabled Page 16 of 42 2008 RuggedCom Inc All rights reserved Rev100 RS900 Family Installation Guide 2 2 2 DC Power Supply Wiring and Grounding 3avs oie 140d 11V 3 SS cecsu DC Chassis Input A Ground Figure 5 DC Power supply wiring and grounding diagram The low voltage DC power supply features reverse polarity protection and dual independent inputs The latter feature allows the connection of two DC sources with the same nominal voltage to provide redundant power supply inputs The DC power supply inputs should be connected as follows 1 Connect to the DC inputs according to the polarity markings on the unit 2 Surge Ground should be connected to the Chassis Ground via a braided cable or other appropriate grounding wire Surge Ground is used as the ground conductor for all surge and transient suppression circuitry internal to the unit 3 Chassis Ground must be connected to the protective earth NOTES 1 Equipment must be installed according to the applicable country wiring codes 2 All line to ground transient energy is shunted to the Surge Ground terminal In cases where users require the i
21. n critical real time control applications RS900 Family Common Product Features Operating temperature 40 to 85 C no fans Fully integrated power supply Power supply options 12 24 48 or 60 VDC and Universal HI 88 300VDC or 84 264VAC Failsafe output relay for critical failure or error alarming Industry standard fiber optical connectors LC SC ST MTRJ Multimode and Singlemode optical transceivers Long haul optics allow distances up to 90 km Advanced layer 2 switching functions including Flow Control Link Aggregation MAC Bridges Rapid Spanning Tree Message Prioritization VLANs and Port Based Network Access Control Page 6 of 42 2008 RuggedCom Inc All rights reserved Rev100 RS900 Family Installation Guide 1 2 RuggedSwitch RS900 9 Port Fiber Optic Ethernet Switch e Up to 9 fast Ethernet ports e Copper and fiber options Power Alarm amp Reset Port 9 10 100Base TX or Ports 3 amp 4 100Base Fx 10 100Base TX or 100Base FX Ports 1 6 10 100Base TX 2008 RuggedCom Inc All rights reserved Page 7 of 42 Rev100 RS900 Family Installation Guide 1 3 RuggedWireless Family of Products Wireless Port Characteristics configuration Configurable as an access client or bridge device IEEE 802 11b g Wireless Access Point with data rates up to 54 Mbps WPA Wi Fi Protected Access with TKIP for enhanced security and encryption WPA2 802 111 with CCMP for robust security and encryption I
22. nputs to be isolated from ground remove the ground braid between Surge and Chassis Ground Note that all line to ground transient protection circuitry will be disabled Page 17 of 42 2008 RuggedCom Inc All rights reserved Rev100 RS900 Family Installation Guide 2 2 3 Failsafe Output Wiring The Failsafe output relay is provided to signal critical error conditions that may occur on the unit The contacts are energized upon power up of the unit and remain energized until an alarm condition or power loss occurs ro Normally Normally Closed Open Common Figure 6 Failsafe Output Relay Page 18 of 42 2008 RuggedCom Inc All rights reserved Rev100 RS900 Family Installation Guide 2 2 4 Dielectric Strength Testing Units which are to have dielectric strength testing HIPOT testing done in the field must have the braided ground cable disconnected during the test This is required in order to prevent the surge suppression circuitry which is connected to surge ground from being activated j4vs a 1MOd Ww O Ollzezsu i Surge Chassis Ground Ground Disconnect connection between Surge Ground amp Chassis Ground Figure 7 Dielectric Strength Testing Page 19 of 42 2008 RuggedCom Inc All rights reserved Rev100 RS900 Family Installation Guide 2 3 HS232 Console Port Wiring The RS232 port is used for configuring the unit A straight through serial cable with a DB 9 connector is required There i
23. of 42 2008 RuggedCom Inc All rights reserved Rev100 RS900 Family Installation Guide 1 7 Bottom Panel Description Console Pot Ghasete Ground Failsafe Relay gt Optional Din Rail Mounting Bracket Figure 2 Bottom Panel Description Page 14 of 42 2008 RuggedCom Inc All rights reserved Rev100 RS900 Family Installation Guide 2 Installation 2 1 Din Rail Mounting An optional DIN rail mounting bracket is available for the unit The figure below details mounting instructions for the standard 1 DIN Rail Optional Din Rail Mounting Bracket Release Direction Figure 3 DIN Rail Mounting Page 15 of 42 2008 RuggedCom Inc All rights reserved Rev100 RS900 Family Installation Guide 2 2 Power Supply Wiring and Grounding 2 2 1 AC Power Supply Wiring and Grounding 34S 1YOd vi E O Ollzezey e Surge Chassis Line Hot Ground Ground AC Neutral Figure 4 Power Supply Inputs The AC power supply inputs should be connected as follows 1 L should be connected to AC Line Hot 2 N should be connected to AC Neutral 3 Surge Ground should be connected to the Chassis Ground via a braided cable or other appropriate grounding wire Surge Ground is used as the ground conductor for all surge and transient suppression circuitry internal to the unit 4 Chassis Ground must be connected to the AC ground terminal NOTES 1 Equipment must be installed accordin
24. rt 7 Ethernet over VDSL Ports 1 6 10 100Base TX lt Port 9 Port 9 Antenna 2 Antenna 2 Page 9 of 42 2008 RuggedCom Inc All rights reserved Rev100 RS900 Family Installation Guide 1 4 RuggedVDSL Family of Products EoVDSL Port Characteristics e Symmetric data rates up to 35 Mbps with distances up to 2 5 km e Asymmetric data rates up to 40 Mbps with distances up to 5 km e Automatically selects fastest data rate based on distance and quality of cable e Manual speed configuration available RS900L RS910L Ethernet over VDSL with integrated 8 Port Ethernet over VDSL with 2 Serial and or 2 Switch Ethernet Ports e 1EoVDSL interface e EoVDSL interface e Up to 8 fast Ethernet ports e 2RS485 RS422 R 232 Serial ports e Copper and fiber options DB9 or RJ45 Serial Fiber interface ST available e 2 Optional Ethernet ports T RuggedVDSL RS910L nk Ac y i L Power Alarm amp Reset Port 9 Ethernet Ports 3 amp 4 Port 9 10 100Base TX Ethernet eee or over VDSL Ports 7 amp 8 100Base FX 10 100Base TX or 100Base FX 4 Ports 1 amp 2 Serial E Uy Ports 1 6 Yj 10 100Base TX 7 Power amp Yi Alarm p CONT Page 10 of 42 2008 RuggedCom Inc All rights reserved Rev100 RS900 Family Installation Guide RS920L Dual Ethernet over VDSL interfaces with integrated Dual Port Serial Server e 2EoVDSL interfaces e 2RS485 RS422 R 232 Serial ports DB9 or RJ45 Serial Fib
25. s no need to crossover the Transmit and Receive signals from the PC side since this has been done internally Figure 8 RS232 Female DCE pin out 8 No Connection 9 NoConnection Table 2 RS232 Female DCE pin out NOTE This port is not intended to be a permanent connection and the cable shall be less than 2m 6 5 ft in length Page 20 of 42 2008 RuggedCom Inc All rights reserved Rev100 RS900 Family Installation Guide 3 Ethernet Ports 3 1 RJ11 Ethernet over VDSL Port 3 1 1 Overview The Ethernet over VDSL EoVDSL port operates in pairs with one unit configured as the Master and the other as the Slave In VDSL literature the terms Central Office CO or Line Termination LT are used interchangeably for the Master and the terms Customer Premise Equipment CPE or Network Termination NT are used interchangeably for the Slave The Master unit dictates the line configuration settings to the Slave so all EoVDSL configuration is done on the Master Data flowing from the Master to the Slave is designated downstream while data flowing from the Slave to the Master is designated upstream RuggedCom offers two flavours of VDSL Universal EoVDSL and Long Reach EoVDSL Universal EoVDSL ports are Master Slave selectable and offer symmetric data rates up to 35 Mbps with distances up to 2 5 km Long Reach EoVDSL ports are fixed as either Master or Slave but offer asymmetric data rates up to 40 Mbps with distances up
26. s reserved Rev100 RS900 Family Installation Guide 6 Technical Specifications 6 1 Operating Environment Ambient Temperature as measured from a 30 cm radius PDI pe une Temperature ks didi surrounding the center of the enclosure Ambient Storage Temperature 40 to 85 C Ambient Relative Humidit 5 to 95 Table 11 Operating Environment 6 2 Power Supply Specifications 12 24 VDC 10 VDC 36 VDC 3 15 T 1 5 kV DC 24 VDC 18 VDC 36 VDC 3 15 T 1 5 kV DC 48 VDC 36 VDC 72 VDC 3 15 T 1 5 kV DC HI 125 250 VDC 88 VDC 300 VDC 3 15 T 4 kV AC HI 110 230 VAC 1 85 VAC 265 VAC 5 5 kV DC Table 12 Power Supply Specifications NOTES 1 Thisis the same power supply for both AC and DC 2 F Denotes fast acting fuse T denotes time delay fuse 3 For continued protection against risk of fire replace only with same type and rating of fuse 6 3 Failsafe Relay Specifications Max Switching Voltage 30VAC 80VDC Rated Switching Current 0 3A Q 30VAC 1A 30VDC 0 3A 80VDC Table 13 Failsafe Relay Specification NOTES 1 Resistive Load 2 For Class 2 circuits only Page 33 of 42 2008 RuggedCom Inc All rights reserved Rev100 RS900 Family Installation Guide Dielectric test voltage 1 minute between coil amp contacts Table 14 Failsafe Relay Isolation 6 4 Ethernet Ports Specifications 6 4 1 RJ11 Ethernet over VDSL Port Specifications EoVDSL CAT 3 UTP or STP 2500m RJ11 Table 15
27. ter and the other as a Slave If the units have a Long Reach EoVDSL port no Master Slave software configuration is necessary since the ports will already be fixed as Master or Slave Once configured as Master and Slave and connected together the units will then attempt to achieve the maximum speed based on the line length and conditions The unit s link LED may flash on and off several times before settling on a final link speed and declaring the port up For detailed configuration options please consult the Rugged Operating System ROS Software User Guide Page 22 of 42 2008 RuggedCom Inc All rights reserved Rev100 RS900 Family Installation Guide 3 1 5 Performance The EoVDSL ports can be configured in two modes Auto Mode and Manual Mode In Auto Mode which is the default mode the unit will step through the different soeeds and automatically select the best bit rate based on current line conditions In Manual Mode the user can select one of the speed settings and the unit will only attempt to attain the set speed If the line conditions degrade reducing the SNR but the unit is able to maintain the link an alarm will be triggered to notify the user of the reduced SNR If the line conditions degrade such that the unit is unable to maintain the current link the unit will restart the scan process if in Auto Mode or re attempt to attain the set speed if in Manual Mode On 24 American Wire Gauge AWG Polyethylene Insulated Cable PIC
28. to 5 km The Universal and Long Reach EoVDSL ports are physically indistinguishable from each other however you can determine which port you have either from the order code or through the software 3 1 2 Wiring VDSL typically operates over 2 wire Category 3 CAT 3 unshielded twisted pair UTP wiring however other categorized or uncategorized twisted pair wiring will work although the performance will vary depending on the distance and cable characteristics It is important that the wiring used does not have any open leads also known as bridged taps or drop lines along its length because this will impact performance by degrading the signal Page 21 of 42 2008 RuggedCom Inc All rights reserved Rev100 RS900 Family Installation Guide 3 1 3 RJ11 Port EoVDSL data ports allow connection using RJ11 male connectors The figure below shows the RJ11 port pin out and LEDs On units with Universal EoVDSL ports the Master LED can be toggled on or off depending on whether the port is set as a Master or Slave On units with Long Reach EoVDSL ports the Master unit will have the LED permanently on while the Slave unit will have the LED permanently off OLink Act Master Figure 9 RJ11 port pin out and LEDs Table 3 RJ11 port pin out Link Established me Tx Activity Table 4 RJ11 port LED description 3 1 4 Configuration amp Setup If the units have Universal EoVDSL ports use the software to configure one unit as a Mas
Download Pdf Manuals