Home
Proliphix Internet Managed Thermostat (IMT) Installation Guide
Contents
1. Switch PoE EPA 24 VAC SP1 Off On On SP2 Off On On SP3 Off Off On SP4 Off Off On To mount the thermostat into the base plate 1 Mount the thermostat into the base plate see page 3 by inserting the top two hinges into the corresponding receptacle holes in the top of the base plate 2 Snap the bottom of the thermostat securely into the base plate Proliphix Internet Managed Thermostat IMT Installation Guide Release 1 0 13 Part No 600 03100 000 Rev 1 Logging In to the Thermostat Verifying the Thermostat s Operating Status This section describes the procedures you can use to verify that the heat cool and fan controls are operating properly on your thermostat Before you begin verify that the HVAC system s power is set to On and HVAC on the thermostat Icd panel is set to Auto Testing the Heat Controls Verify the HVAC mode is set to either Auto or Heat Continuously press the Up arrow until the heat set point is higher than the temperature reading A flame icon appears and the HVAC system activates the heat Testing the Cool Controls Verify the HVAC mode is set to either Auto or Cool Continuously press the Down arrow until the cool set point is lower than the temperature reading A snowflake and fan icon appears and the HVAC system activates the cool and fan Testing the Fan Operation Press the fan button until the mode is set to On A fan icon appears and the fan circuit is now act
2. scratched broken or modified plastics other cosmetic damage or parts that have been altered defaced or removed or the scratching cracking or breakage of the product This warranty is not transferable THE FOREGOING WARRANTIES ARE THE SOLE AND EXCLUSIVE WARRANTIES EXPRESS OR IMPLIED GIVEN BY Proliphix INCONNECTION WITH THE PRODUCT AND Proliphix DISCLAIMS ALL IMPLIED WARRANTIES INCLUDING IMPLIED WARRANTIES OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT OF THIRD PARTY RIGHTS Proliphix DOES NOT PROMISE THAT THE PRODUCT IS ERROR FREE OR WILL OPERATE WITHOUT INTERRUPTION Proliphix WILL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES OR FOR ANY OTHER LOSSES EXPENSES OR DAMAGES RELATING TO PRODUCT DEFECTS OR FAILURES CUSTOMER S SOLE REMEDY AND Proliphix S SOLE OBLIGATION WITH RESPECT TO ANY PRODUCT DEFECTS OR FAILURES REGARDLESS OF WHETHER YOUR CLAIM IS ASSERTED IN CONTRACT TORT STRICT LIABILITY OR OTHERWISE SHALL BE AT Proliphix S SOLE OPTION REPAIR REPLACEMENT OR REFUND OF THE PRICE PAID IN NO EVENT WILL Proliphix S LIABILITY WITH RESPECT TO A PRODUCT EXCEED THE PRICE PAID FOR SUCH PRODUCT This warranty statement supersedes all previous warranties This warranty extends to products purchased directly from Proliphix or an authorized Proliphix agent dealer distributor or reseller Proliphix Internet Managed Thermostat IMT Installation Guide Release 1 0 Part No 600 03100 000 Rev 1 Mate
3. EA Nicom s3 _ NO S2 1 Nc g Se COM Si S1 AUX 2 RELAY JUMPERS 1 Reverse for Heat Cool Dual Stage HVAC System m The wiring colors shown above are examples of commonly used colors and may Note differ depending on the HVAC wiring that is used 6 Proliphix Internet Managed Thermostat IMT Installation Guide Release 1 0 Part No 600 03100 000 Rev 1 Installing and Wiring the Thermostat To wire the base plate terminals 1 Use Table 2 on page 4 to match the letter of your existing thermostat wire to the corresponding terminal letter on the Proliphix base plate 2 Strip the wire insulation from the wire ends Verify that the wire ends are straight To avoid damaging the labels use caution when handling the wires and push any excess wire back into the wall 3 Using Figure 1 on page 5 or Figure 2 on page 6 as a guide connect the labeled wires to the terminal post with the corresponding letter on the IMT base plate For example connect the wire labeled W1 to the W1 terminal post 4 Loosen the terminal post screw used to secure the wires Insert the wire straight down into the square hole and secure the corresponding screw to the wire AN To avoid damage to the Proliphix base plate stop unscrewing the terminal post Caution Crews when you feel a slight stop or resistance 5 Verify that the wire is securely attached to the ter
4. HVAC installer about the RVS type for your heat pump Provides stage 1 heat or cool depending on the activation of the RVS Provides stage 2 heat or cool depending on the activation of the RVS Figure 1 shows an example of a single stage shown in blue and dual stage shown in yellow Fuel Burner HVAC system connecting to an IMT base plate Figure 1 Single Dual Stage Fuel Burner HVAC Connections IMT Base Plate f yh a k riS ka Kesh va waa Pa a a vamavd ma a ETHERNET AUX SENSORS RELAYS AO NO Ao 2 Nc s yN g Nco s3 LL J No S2 1 Nc 63 Nel com S1 RJ i AUX RELAY JUMPERS 1 z 2 8 24VAC Source HVAC System The wiring colors shown above are examples of commonly used colors and may Note differ depending on the HVAC wiring that is used Proliphix Internet Managed Thermostat IMT Installation Guide Release 1 0 5 Part No 600 03100 000 Rev 1 Installing and Wiring the Thermostat Figure 2 shows an example of a dual stage Heat Pump HVAC system with reverse activate for heat cool connecting to an IMT base plate 7 The second compressor wire is not present in a single stage heat pump Note Figure 2 Dual Stage Heat Pump HVAC Connections IMT Base Plate Al Ey fs N ey ae T568A T568B ke zi PAM PAM i71 OU CPA ee ETHERNET AUX SENSORS RELAYS AO NO AO 2 NC s3
5. Part No 600 03100 000 Rev 1 Installing and Wiring the Thermostat Remove the base plate from the wall and drill two or three holes at the marked locations for drywall drill 3 16 holes for plaster drill 7 32 holes Gently tap the wall anchors included in the packaging into the drilled holes until they are flush with the wall Pull the wires through the base plate and position the base plate over the screw holes Attach the base plate to the wall using three 1 screws included in the packaging Wiring the Base Plate Terminals Note This section describes how to wire the base plate terminals Use the instructions in this section and refer to m Table 2 and Figure on page 5 to wire the IMT base plate terminals for Fuel Burner HVAC A Fuel Burner typically burns fossil fuel like oil or gas and does not have a wire used as a reversing valve m Table 2 and Figure 2 on page 6 to wire the IMT base plate terminals for Heat Pump HVAC A Heat Pump configuration always has a wire used to control a reversing valve Refer to the labels you placed on the wires when you removed the existing thermostat See page 1 Some newer Heat Pumps use traditional Fuel Burner wiring schemes without a Reversing Valve RV Therefore you may have to use a Fuel Burner wiring scheme to control your Heat Pump Refer to your Heat Pump manual for wiring details You must know the type of Reversing Valve in your heat pump Refer to your Heat Pu
6. connectors Table 5 Auxiliary Relay Connectors Auxiliary Relay Description NO Port 1 Auxiliary Relay Normally Open NCI Port 1 Auxiliary Relay Normally Closed COM1 Port 1 Auxiliary Relay Common NO2 Port 2 Auxiliary Relay Normally Open NC2 Port 2 Auxiliary Relay Normally Closed COM2 Port 2 Auxiliary Relay Common Proliphix Internet Managed Thermostat IMT Installation Guide Release 1 0 9 Part No 600 03100 000 Rev 1 Installing and Wiring the Thermostat Table 6 describes the sensor connectors Table 6 Sensor Connectors Sensor Description S1 Port 1 Remote Sensor Positive S1 Port 1 Remote Sensor Negative S2 Port 2 Remote Sensor Positive S2 Port 2 Remote Sensor Negative S3 Port 3 Remote Sensor Positive S3 Port 3 Remote Sensor Negative Configuring Auxiliary Relay Jumpers The Auxiliary Relays are powered from RC when the jumpers are installed Figure 5 shows how to configure the Auxiliary Relay jumpers Auxiliary Relay 1 and 2 can be configured independently from each other Figure 5 Auxiliary Relays with Jumpers Aux Relay 2 2 powered by RC Aux Relay 1 powered by RC When the jumpers are removed see Figure 6 the Auxiliary Relays are configured to use an external power source Figure 6 Auxiliary Relays without Jumpers Aux Relay 2 2 w a powered by external source Aux Relay 1 1 powered by external source 10 Proliphix Internet Managed Thermostat IMT Ins
7. Proliphix Internet Managed Thermostat IMT Installation Guide Release 1 0 ENERGY STAR PROLIPHI X Part No 600 03100 000 Rev 1 May 2010 Technical Support Warranty Information ii When contacting Proliphix Inc for technical assistance please have the following information available m Product model and serial number m Type of heating cooling system example gas oil or electric warm air hot water heat pump steam or gravity Location and number of wires attached to your Proliphix thermostat For additional assistance please contact Proliphix Inc Technical Support 9 00 AM to 5 00 PM Eastern Time Monday to Friday Web www Proliphix com Email support Proliphix com Telephone 1 866 475 4846 Fax 978 692 3378 Proliphix Inc warrants its products to be free from manufacturing defects in materials and workmanship under normal use for a period of 3 years for the IMT series thermostats from the date of purchase Proliphix shall not be liable to honor the terms of this warranty if the product has been used in any other application other than that for which it was intended or if it has been subjected to misuse accidental damage acts of God modification or improper installation procedures Furthermore this warranty covers only products which have all original and unaltered markings and labels serial numbers model numbers etc of manufacture This limited warranty does not cover the repair of cracked
8. RH only default or RC only W1 W2 Y1 Y2 G RH and RC Supplies separate RH supplies W1 W2 G RC supplies Y1 and Y2 RH and RC Supplies separate RH supplies W1 and W2 RC supplies Y1 Y2 G Figure 7 Jumper Configuration PWR RH amp RC jumpered together Fan Relay G tied to RC FAN PWR RH amp RC separated Fan Relay G tied to RC FAN PWR RH amp RC separated Fan Relay G tied to RH Proliphix Internet Managed Thermostat IMT Installation Guide Release 1 0 Part No 600 03100 000 Rev 1 Installing and Wiring the Thermostat The IMT550c can be powered from different sources presented on the following Ethernet CAT5 5E CAT6 interface see Figure 8 m A Power over Ethernet PoE source is an Ethernet router switch or mid span device that complies with the 802 3af Power over Ethernet standard IMT550c only m Proliphix Ethernet Power Adapters EPA are multi port power injectors capable of supplying power to either two EPA 20 or six EPA 60 Proliphix Network Thermostats IMT550c and IMT550w m 24VAC is power from the HVAC system which requires RH and C to both be connected to provide power to the thermostat IMT550c and IMT550w Figure 8 shows the four power sources Figure 8 Power Sources Table 9 shows how to configure the IMT for different power sources Table 9 Power Source Configuration
9. ats Note Z Caution The label located on the inside of the base plate see Figure 4 shows several color coded wiring schemes for Ethernet CATS CATSE CAT6 connections To wire the Ethernet network refer to Figure 4 and match the label number to the Proliphix base plate number for CATS CATSE CAT6 color coding If the other end of the CAT5 CAT5E CAT6 cable is connected to a Proliphix EPA 20 60 Ethernet Power Adapter follow the wiring scheme for T568A All wiring must conform to local codes and ordinances The distance between CAT5 CATSE CAT6 cables and HVAC cables should be a minimum of one inch Proliphix Internet Managed Thermostat IMT Installation Guide Release 1 0 Part No 600 03100 000 Rev 1 Installing and Wiring the Thermostat Figure 4 shows the RJ 45 Ethernet plug pinout assignments for the T568A and T568B wiring standards Figure 4 RJ 45 Ethernet Plug Pinout Assignments for T568A and T568B 12345678 12345678 OO GiB BiG Br Br Gi G Ol B Bi OBr Br Table 4 describes the pinout assignments for the T568A and T568B wiring standards Table 4 T568A and T568B Pinout Assignments Pin Number T568A Wire Color T568B Wire Color 1 Green White Orange White 2 Green Orange 3 Orange White Green White 4 Blue Blue 5 Blue White Blue White 6 Orange Green 7 Brown White Brown White 8 Brown Brown Configuring Auxiliary Relay and Sensors Table 5 describes the Auxiliary Relay
10. ding interference that may cause undesired operation Proliphix Internet Managed Thermostat IMT Installation Guide Release 1 0 iii Part No 600 03100 000 Rev 1 Proliphix Internet Managed Thermostat IMT Installation Guide Release 1 0 Part No 600 03100 000 Rev 1 Overview The Proliphix Internet Managed Thermostat IMT provides a rich set of innovative features including the ability to configure settings through a graphical interface either locally or from any remote location The c model suffix thermostats can be connected via secure wired Ethernet to a home small business or light commercial data network while the w model suffix thermostats support 802 11 b g connections This guide describes how to physically install the IMT Table 1 describes the model specific features that are important to note during the installation Table 1 IMT Features Model Wired 802 11 b g Humidity Aux Relays Power Ethernet wireless Sensing 2 Method s IMT550c X X X m EPA m PoE m HVAC IMT550w X X X m EPA m HVAC Installing the Thermostat This section describes the required tools guidelines and installation instructions for the IMT N Preventing electrostatic discharge ESD Static electricity may cause damage to the components on the thermostats circuit module Do not remove the thermostat from the protective bag until you are ready to install the thermostat Caution Required Tools T
11. he following tools are required to install the Proliphix thermostat m 1 or 2 Phillips head screwdriver ms Drill with a 3 16 or 7 32 bit Punchdown tool included with the thermostat m Terminal block screw driver included with the thermostat Proliphix Internet Managed Thermostat IMT Installation Guide Release 1 0 1 Part No 600 03100 000 Rev 1 Installation Guidelines Installation Guidelines Use the following guidelines to install the IMT KO Ifyou are replacing an existing thermostat mount the thermostat in the same Tip location as the thermostat in which you are replacing Install the thermostat on an inside wall about 5 feet 1 5m above the floor and in a room that is used often Install the CAT5 CAT5E CAT6 cabling from the wiring center to the thermostat installation site for model IMT550c This is not required for the IMT550w model 802 11 b g wireless Install the thermostat in an area or room with adequate air circulation and where there are no unusual heating cooling conditions such as sunlight near a lamp radio television radiator register or fireplace near hot water pipes in a wall near a stove on the other side of the wall on a wall separating an unheated room or in a draft from a stairwell door or window in a corner or alcove or behind an open door Install the unit after all construction work and painting is complete Install the unit in an unobstructed location where there a
12. ive Logging In to the Thermostat 14 Log in to the TMI as the Administrator as follows Enter the username admin Enter the password admin default Proliphix Internet Managed Thermostat IMT Installation Guide Release 1 0 Part No 600 03100 000 Rev 1
13. minal post in the base plate by gently tugging on the wire Configuring Remote Sensors The Proliphix thermostats provide three remote external sensor ports The IMT supports Thermistor 0 5v Analog and 4 20mA Current Loop Go to www proliphix com for a complete list of supported sensors You must configure the two switches for each sensor to match the sensor category See Figure 3 and Table 3 on page 8 Figure 3 shows and example of the remote sensor switch settings Figure 3 Remote Sensor Switch Settings Base Plate Label i POWER SWITCH SETTINGS p BATTERY SWITCH PoE EPA 24vac Ba e O ON l ON 2 Of ON ON SENSOR Ls Orr Orr ON L SWITCHES E a a OFF_A ON TESTED TO COMPLY WITH FCC STANDARDS FOR HOME AND OFFICE USE ER rroripnix 1 866 4P LIVING www proliphix com Proliphix Internet Managed Thermostat IMT Installation Guide Release 1 0 7 Part No 600 03100 000 Rev 1 Installing and Wiring the Thermostat C Note Table 3 lists the remote sensor switch settings Only one sensor can be connected to each port Table 3 Remote Sensor Switch Settings Remote Sensor Thermistor 0 5v Analog 4 20mA Current Loop Remote Sensor 1 ST1 ON OFF OFF SLI OFF OFF ON Remote Sensor 2 ST1 ON OFF OFF SLI OFF OFF ON Remote Sensor 3 ST1 ON OFF OFF SLI OFF OFF ON Connecting CAT5 CAT5E CAT6 Wiring for Ethernet Networks to IMT550c Thermost
14. mp manual for more information Table 2 lists the standard HVAC terminal label required to support the single stage and dual stage Fuel Burner and Heat Pump applications Table 2 Terminal Conversion Chart HVAC Single Stage Dual Stage Single Stage Dual Stage Terminal Fuel Burner Fuel Burner Heat Pump Heat Pump c 24VAC common 24VAC common 24VAC common 24VAC common RH 24VAC hot 24VAC hot 24VAC hot 24VAC hot RC 24VAC hot 24VAC hot 24VAC hot 24VAC hot Wil Heat Ist stage Heat Auxiliary Heat Auxiliary Heat w2 gt not used 2nd stage Heat RVS O B RVS O B y1 Cool Ist stage Cool Ist stage Ist stage Compressor Compressor y24 not used 2nd stage Cool not used 2nd stage Compressor Proliphix Internet Managed Thermostat IMT Installation Guide Release 1 0 Part No 600 03100 000 Rev 1 Installing and Wiring the Thermostat Table 2 Terminal Conversion Chart Continued HVAC Single Stage Dual Stage Single Stage Dual Stage Terminal Fuel Burner Fuel Burner Heat Pump Heat Pump G Fan Fan Fan Fan The 24VAC common must be in the same AC phase as the 24VAC source RH or RC If the thermostat is connected to RH only or RH and RC then C must be the RH common If the thermostat is connected to RC only then C must be the RC common The RVS is either activate for heat B terminal or activate for cool O terminal You can program this function on the relay output through the web interface and the LCD screens Consult your
15. re no objects on the wall above or below the thermostat or other obstructions such as furniture restricting vertical airflow It is not necessary for the thermostat to be level N Prior to installing or servicing the thermostat turn off electricity to the entire Caution HVAC system do not turn electricity back on until all work is complete Do not jumper wires together to test the system This may cause harm to your HVAC system and damage the thermostat and therefore void the warranty All wiring must conform to local codes and ordinances The distance between CAT5 CAT5E CAT6 cables and HVAC cables should be a minimum of one inch Proliphix Internet Managed Thermostat IMT Installation Guide Release 1 0 Part No 600 03100 000 Rev 1 Before you Begin Before you Begin If you are removing an existing thermostat Proliphix recommends that you label each connection as you remove the wiring You will use these same wires and labels when you connect the IMT See Wiring the Base Plate Terminals page 4 Use the following steps to remove an existing thermostat 1 Turn off power to the entire HVAC system or the fuse circuit breaker panel 2 Remove the cover from the existing thermostat If the cover does not snap off when pulled firmly from the top or bottom check the owners manual for removal procedures 3 Disconnect each wire Label the wires with the terminal designation from the existing thermostat Place the label abo
16. rial No merchandise may be returned for credit exchange or service without prior authorization from Proliphix Return To obtain warranty service for Proliphix products contact Proliphix Customer Service 1 866 475 4846 and Procedure request a Return Material Authorization RMA number Products may be returned for credit exchange or service with a Proliphix RMA number and with proof of purchase Enclose a note explaining the symptoms of the problem stating the RMA number and the name address and phone number of the company or individual contact Authorized returns must be shipped prepaid to Proliphix at Proliphix Inc 3 Lan Drive Suite 100 Westford MA 01886 The RMA number must be clearly marked on the outside of the package Products received without an RMA number or without shipping prepaid will be subject to refusal by Proliphix Proliphix reserves the right to charge a 15 restocking fee plus shipping costs on any products returned without an RMA Return shipping charges following repair of items under warranty shall be paid by Proliphix via standard ground carrier In the event that repairs are found to be non warranty return shipping charges will be paid by the purchaser FCC Model IMT550c and IMT550w Made in the USA This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received inclu
17. tallation Guide Release 1 0 Part No 600 03100 000 Rev 1 Installing and Wiring the Thermostat Table 7 describes what relays are active for the HVAC and fan state Table 7 Relay Matrix w1 W2 Y1 Y2 G Fuel Burner Heat 1h X x Heat2 2h X X x Cooll 1c X X Cool2 2c X X X Fan X Heat Pump Heatl 1h xb X X Heat2 2h xb X X X Aux Heat 3h X xb X X X Cooll 1c xe X X Cool2 2c xe X X X Fan X a If fan on heat is enabled If Heat Pump is a model which activates the reversing valve B for heat mode Tf Heat Pump is a model which activates the reversing valve O for cool mode Cl Aux Heat is the last stage whether you have a single or dual stage heat pump Note Proliphix Internet Managed Thermostat IMT Installation Guide Release 1 0 11 Part No 600 03100 000 Rev 1 Installing and Wiring the Thermostat Mounting the Thermostat into the Base Plate 12 The Proliphix thermostat contains jumpers to configure the HVAC power settings The power settings determine which HVAC power source RH or RC is configured to turn on each HVAC system cool heat and fan Most applications use only RH power The Proliphix thermostat is shipped from the factory with the RH and RC jumpered together Table 8 lists the possible HVAC power configurations Table 8 HVAC Power Configuration HVAC Power Configuration Supplies
18. ut 1 2 away from the end of the wire to allow for stripping of the ends Cc If this is a new installation obtain the wire designations from the HVAC installer Note 4 Remove the existing thermostat from the wall Installing and Wiring the Thermostat This section describes a two step installation process in which you install or mount the thermostat base plate and wire the thermostat Inserting the Battery Insert the battery that is shipped with the thermostat before installing the thermostat on the wall The battery needs to be inserted to ensure the time of the thermostat remains accurate during a power outage See Figure 3 on page 7 for battery location and orientation Installing the Base Plate Perform the following steps to mount the thermostat base plate on the wall 1 Review the Installation Guidelines on page 2 and position the base plate in an appropriate location on the wall Ensure the location allows you to access and pull the wires through the opening in the base plate 7 There are four mounting holes on the backplate that allow for mounting in a single Note vertical or horizontal oriented single gang electrical box using only two screws If you are installing the backplate on drywall directly then use three screws 2 Using a pencil mark the center of the screw holes on the left and right side and bottom center of the base plate Proliphix Internet Managed Thermostat IMT Installation Guide Release 1 0 3
Download Pdf Manuals
Related Search
Related Contents
Icon OSE-S 1100 Burner for pellets USER`S MANUAL www.burnpell.com FILCORD 253C MEDIATHEQUE - Quint Jou Jye Computer BW-B430JL power supply unit Aire Acondicionado (Modelo Split - Modelo LG / Blue Star) Manual DreamLine SHEN-2234340-01 Installation Guide 公園・街路樹等病害虫・雑草管理暫定マニュアルの改訂について(案) Copyright © All rights reserved.