1. You may wish to place several boards under the frame of your power chair to raise it off of the ground during periods of prolonged storage This takes the weight off the tyres and reduces the possibility of flat spots developing on the areas of the tyres contacting the ground Disposal of Your Power Chair Your power chair must be disposed of according to applicable local and national statutory regulations Contact your local waste disposal agency or Quantum Rehab Dealer for information on proper disposal of power chair packaging metal frame components plastic components electronics and batteries Cleaning and Disinfection E Usea damp cloth and mild non abrasive cleanser to clean the plastic and metal parts of your power chair Avoid using products that may scratch the surface of your power chair E Ifnecessary clean your product with an approved disinfectant Make sure the disinfectant is safe for use on your product before application WARNING Follow all safety instructions for the proper use of the disinfectant and or cleaning agent before applying it to your product Failure to comply may result in skin irritation or premature deterioration of upholstery and or power chair finishes WARNING Never hose off your power chair or place it in direct contact with water Your power chair has a painted ABS plastic body shroud that allows it to be easily wiped clean with a damp D cloth WARNING Never use any chemicals to clean a vinyl
2. aa aa a 20 www quantumrehab com Quantum Dynamo 1107 IV ASSEMBLY DISASSEMBLY INITIAL ASSEMBLY Your power chair may require some assembly either before initial use or after transportation It may also require disassembly to make some comfort adjustments Figure 10 details those parts of the power chair that are designed to be disassembled and assembled by an end user or by a qualified carer before using the product or making comfort adjustments NOTE Any nylon insert lock nut removed during the disassembly or adjustment of the power chair must be replaced with a new nut Nylon insert lock nuts should not be reused as it may cause damage to the nylon insert resulting in a less secure fit Replacement nylon insert lock nuts are available at local hardware stores or through your Quantum Rehab Dealer SEAT INSTALLATION ARMREST ANGLE ADJ USTMENT SEAT HEIGHT ANGLE ADJ USTMENT CONTROLLER MOUNTING CONTROLLER POSITION FOOT PLATFORM HEIGHT DEPTH ADJ USTMENT ANTI TIP WHEEL HEIGHT ADJ USTMENT Figure 10 Quantum Dynamo 1107 Assembly View Quantum Dynamo 1107 www quantumrehab com 21 IV ASSEMBLY DISASSEMBLY Seat Installation Your power chair uses T handle detent pins seat towers and seat mount connectors to connect the Synergy Seat to the power base See figure 11 For more information refer to the manual supplied with your seating system WARNING Do not pick up the seat assembly by the armrests They are free to
3. 4 Ideal Transfer Position WARNING Before transferring position yourself as far back as possible in the power chair seat to prevent the power chair from tipping forward during transfer j WARNING Avoid putting all of your weight on the power chair armrests and do not use the armrests A for weight bearing purposes such as transfers Such use may cause the power chair to tip resulting ina fall from the power chair and personal injury WARNING Avoid putting all of your weight on the foot riggings Such use may cause the power chair to tip User Positioning Pride recommends that all users be seated in an upright position with their pelvis positioned as far rearward as possible in the power chair seat All users need to discuss pelvic positioning with their Quantum Rehab Dealer therapist s or healthcare professional to determine appropriate pelvic position when seated on the power chair based on the user s individual medical needs Prescription Drugs Physical Limitations Users must exercise care and common sense when operating a power chair This includes awareness of safety issues when taking prescribed or over the counter drugs or when the user has specific physical limitations if you have certain physical limitations Some medications and limitations may impair your ability A WARNING Consult your physician if you are taking prescribed or over the counter medication or K to operate your power ch
4. 5 WARNING Do not use a high pressure hose to inflate your tyres E Use arubber conditioner on the tyre sidewalls to help preserve them WARNING Never use a rubber conditioner on the tread area of the tyres doing so may make the tyres slippery and cause your power chair to skid 34 www quantumrehab com Quantum Dynamo 1107 VII CARE AND MAINTENANCE All wheel bearings are prelubricated and sealed They require no subsequent lubrication E The body shroud has been sprayed with a clear sealant coating You can apply a light coat of car wax to help it retain its high gloss appearance Check all electrical connections Make sure they are tight and are not corroded KEN AN WARNING Even though the power chair has passed the necessary testing requirements CY AN for ingress of liquids you should keep electrical connections away from sources of L Y K dampness including direct exposure to water or bodily fluids and incontinence Check oo electrical components frequently for signs of corrosion and replace as necessary Daily Checks With the controller turned off check the joystick Make sure it is not bent or damaged and that it returns to the neutral position when you release it Check the rubber boot around the base of the joystick for damage Visually inspect the boot Do not handle or try to repair it See your Quantum Rehab Dealer if there is a problem E Visually inspect the controller cable Make sure that it is n
5. Serial Number Left Motor Serial Number Right Motor Serial Number Fit and Finish Performance Pride keeps a more detailed report on file at the factory Date Inspected Inspector T NF MANU3 449 Product Serial
6. The Quantum Dynamo 1107 has two main assemblies the seat assembly and the power base assembly See figure 5 Typically the seat assembly includes the armrests seatback and seat base The power base assembly includes two motor brake assemblies two drive wheels two anti tip wheels two castor wheels two battery boxes and wiring harnesses See figures 5 6 and 7 SEATBACK ARMRESTS SEAT ASSEMBLY CONTROLLER as 7 SEAT BASE HARNESS N CONTROLLER POWER BASE ASSEMBLY CASTOR WHEEL DRIVE WHEEL ANTI TIP WHEELS Figure 5 The Quantum Dynamo 1107 SaaS SSS SSS SS SSS SSS SSS SSS SS SSS Quantum Dynamo 1107 www quantumrehab com 17 lll YOUR POWER CHAIR REAR SEAT MOUNT CONNECTORS BATTERY FRONT SEAT MOUNT CONNECTORS FRONT SEAT MOUNT CONNECTORS MANUAL TILT CONTROLLER CONNECTOR Lia FREEWHEEL LEVER LD i EEA 4 H l s t MOTOR BRAKE ASSEMBLY Ui Ss 2 Q R CO A US Ad Figure 6 The Quantum Dynamo 1107 Power Base Electrical Components The electrical components consist of the controller assembly the batteries and the motors The batteries motor and controller power module are located on the power base assembly See figures 6 and 7 The controller is located on the seat assembly Connectivity between the controller and the motors the batteries and the battery charger is provided by one or more wiring harnesses Controller Connector The controller connector
7. batteries for more than 24 hours at a charging cycle How can I get maximum range or distance per charge Rarely do you have an ideal driving situation such as smooth flat hard terrain with no wind hills or curves More often you are presented with hills pavement cracks uneven and loosely packed surfaces curves and wind All of these factors will affect the distance or running time per battery charge Below are a few suggestions for obtaining the maximum range per charge E Always charge the batteries fully prior to your trip E Plan your trip in advance to avoid inclines if possible E Limit baggage weight to essential items E Try to maintain an even speed and avoid stop and go driving What type of batteries should I use We recommend deep cycle batteries that are sealed and maintenance free Both AGM and Gel Cell are deep cycle batteries that are similar in performance Refer to the specifications table for more battery information 32 www quantumrehab com Quantum Dynamo 1107 VI BATTERIES AND CHARGING A N WARNING Corrosive chemicals contained in batteries Use only AGM or Gel Cell N N batteries to reduce the risk of leakage or explosive conditions Why do my new batteries seem weak Deep cycle batteries employ a much different chemical technology than that used in car batteries nickel cadmium nicads or in other common battery types Deep cycle batteries are specifically designed to provide power drain down their c
8. frequently exposed to sources of water such as incontinence should be inspected often for corrosion and electronic components may need to be replaced frequently Temperature E Some of the parts of your power chair are susceptible to extreme changes in temperature Always keep your power chair between the temperatures of 8 C 18 F and 50 C 122 F E Inextremely cold temperatures the batteries may freeze The specific temperature at which they freeze depends on a number of factors such as battery charge usage and composition of the batteries e g AGM or Gel Cell E Temperatures above 50 C 122 F may cause your power chair to operate at a reduced speed This reduced speed is a safety feature built into the controller that helps prevent damage to the motor and other electrical components General Guidelines E Avoid knocking or bumping the controller especially the joystick E Avoid prolonged exposure of your power chair to extreme conditions such as heat cold or moisture E Keep the controller clean E Check all connectors to ensure that they are all tight and secured properly E Make sure the drive tyres are inflated to 2 4 bar 35 psi 240 kPa if equipped with pneumatic tyres WARNING Make sure your tyres are inflated to 2 4 bar 35 psi 240 kPa Do not underinflate or IN overinflate your tyres Low pressure may result in loss of control and overinflated tyres may AN burst Overinflating tyres can cause them to explode cC
9. healthcare professional WARNING Keep your hands away from the tyres when driving Be aware that loose fitting clothing can become caught in drive tyres WARNING Do not bend lean or reach for objects if you have to pick them up from the floor by reaching down between your knees or if you have to reach over the back of the seat Movements such as these may change your centre of gravity and the weight distribution of the power chair possibly causing your power chair to tip a 14 www quantumrehab com Quantum Dynamo 1107 Ie SARE a ay Transfers Transferring onto and off of your power chair requires a good sense of balance Always have an attendant or healthcare pro fessional present while learning to properly transfer yourself To eliminate the possibility of injury Pride recommends that you or a trained attendant perform the following tasks before at tempting a transfer E Turn off the power to the controller E Ensure your power chair is not in freewheel mode See III Your Power Chair E Turn the castor wheels toward the transfer destination to improve power chair stability during transfer E Make sure both armrests are flipped up or removed from your power chair E Flipup the foot platform or move the leg rests aside this will help to keep your feet from getting caught on the foot ngging during the transfer E Reduce the distance between your power chair and the ob ject you are transferring onto Figure
10. pivot and you may N lose control of the seat if they do so A WARNING Depending on your lifting ability we recommend that two people remove the seat to avoid possible damage to the seat or your power chair To install the seat 1 Position the seat directly over the power base so that the seat towers line up with the seat mount connectors See figure 11 2 Slide the seat towers down into the seat mount connectors 3 Align the locating holes in the seat towers with those in the seat mount connectors and insert the T handle ball detent pins through the holes To remove the seat 1 Remove the four 4 T handle ball detent pins securing the seat to the power base 2 Allow the seat to rest on the seat mount connectors 3 Lift the seat directly up See figure 11 NOTE You may find it necessary to rock the seat gently from side to side to free the seat towers from the seat mount connectors SEAT TOWER 4 SEAT MOUNT ge D CONNECTOR we T HANDLE BALL DETENT PIN Figure 11 Seat Installation 22 www quantumrehab com Quantum Dynamo 1107 IV ASSEMBLY DISASSEMBLY Power Base Disassembly The Quantum Dynamo 1107 power base disassembles into six parts for easy transportation and storage See figure 12 To disassemble your power chair Turn off the power to the controller Disconnect the controller harness from the power base See figure 6 Remove the seat Press the foot platform release button and lift off
11. power chair safely on lawns and in park areas Reduce your power chair s speed when driving on uneven terrain and or soft surfaces Avoid tall grass that can entangle the running gear Avoid loosely packed gravel and sand If you feel unsure about a driving surface avoid that surface Inclement Weather Precautions Exposure of your power chair to inclement weather conditions should be avoided whenever possible If suddenly caught up in rain snow severe cold or heat while operating your power chair proceed to shelter at the earliest opportunity Thoroughly dry your power chair before storing charging or operating your power chair KEN PROHIBITED Operating in rain snow salt mist spray conditions and on icy slippery surfaces can have an adverse affect onthe electrical system Maintain and store your power chairina dry and YW clean condition i WARNING Prolonged exposure to hot or cold conditions may affect the temperature of upholstered and non upholstered items on the power chair possibly resulting in skin irritation Exercise caution when using the power chair in extremely hot or cold conditions or when exposing your power chair to direct sunlight for prolonged periods of time Stationary Obstacles Steps Kerbs etc Proceed with extreme caution when driving near raised surfaces unprotected ledges and or drop offs kerbs porches stairs etc Be sure your power chair is traveling perpendicular to any kerb you may be
12. required to navigate See figure 2 WARNING Do not attempt to have your power chair climb or descend an obstacle that is higher than 5 cm 2 in unless you have the assistance of an attendant IN WARNING If your power chair is equipped with a kerb climber do not attempt to climb any kerb f in excess of 5cm 2 in in height Do not approach kerbs at an angle instead approach any kerb you intend to ascend or descend in the forward position WARNING Do not attempt to have your power chair proceed rearward down any step kerb or other obstacle This may cause the power chair to tip Figure 2 Correct Kerb Approach Figure 3 Incorrect Kerb Approach 12 www quantumrehab com Quantum Dynamo 1107 hie SAFETY Stairs and Escalators Power chairs are not designed to travel up or down stairs or escalators Always use a lift AN C Doors E Determine if the door opens toward or away from you E Drive your power chair gently and slowly forward to push the door open or drive your power chair gently and slowly rearward to pull the door open WARNING Never use your power chair to negotiate steps or escalators gt Lifts Modern lifts have a door edge safety mechanism that when pushed reopens the lift door s E Ifyou are in the doorway of a lift when the door s begin to close push on the rubber door edge or allow the rubber door edge to contact the power chair and the door will reopen E Use care that handbags p
13. towers attached to the seat base to the desired height SEAT MOUNT CONNECTOR T HANDLE BALL DETENT PINS NOTE You may find it easier to adjust the front towers first and then the rear towers 3 Align the locating hole in the seat tower with the one in the seat mount connector and reinsert the T handle ball detent pin for each tower See figure 14 NOTE Change the seat angle dump by raising or low THANDLE BALL DETENT PINS ering only one set of towers front or back Figure 14 Seat Height Adjustment Quantum Dynamo 1107 www quantumrehab com 25 V COMFORT ADJUSTMENTS Controller Position You can position the controller for either left hand or right hand use MANDATORY Prevent controller harness damage Avoid routing the controller harness on the outside of the armrest pad Route the harness under the armrest or toward the inside of the haw armrest pad Use correct tie down points for the controller harness to prevent the harness from getting caught in the drive tyres pinched in the seat frame or damaged when passing through doorways To extend the controller 1 Flip up the armrest so it is perpendicular to the floor 2 Loosen the setscrew on the controller bracket 3 Slide the controller into or out of the armrest to the de sired position 4 Tighten the setscrew to secure the controller To change the controller position 1 Turn off the power to the controller 2 Disconnect the co
14. A ZH hele T E Wk VL eh N CONTROLLER POWER MODULE Figure 7 Quantum Dynamo 1107 Electrical Components Quantum Dynamo 1107 www quantumrehab com 19 lll YOUR POWER CHAIR Manual Freewheel Levers Your power chair has a manual freewheel lever on each motor See figure 6 Manual freewheel levers enable you to disengage the drive motors from the gearboxes and manoeuvre the chair manually WARNING Do not use the power chair while the drive motors are disengaged Do not disengage the drive motors when the power chair is on an incline or decline as the unit could roll on its own Only engage the freewheel mode when on a level surface A WARNING It is important to remember that when your power chair is in freewheel N mode the braking system is disengaged 9 To engage or disengage the drive motors 1 Locate the lever on top of each motor 2 Pull the two levers upward to engage the drive motors drive mode See figure 8 3 Push the two levers downward to disengage the drive motors freewheel mode See figure 9 If a lever is difficult to move in either direction slightly rock the power chair back and forth The lever should then move to the desired position A WARNING Do not use the freewheel lever handles as tie down points to secure the product Ai VENN MANUAL FREEWHEEL LEVER MANUAL FREEWHEEL LEVER Figure 8 Drive Mode Drive Engaged Figure 9 Freewheel Mode Drive Disengaged
15. OTE If you discover a problem contact your Quantum Rehab Dealer for assistance Quantum Dynamo 1107 www quantumrehab com 9 II SAFETY Weight Limitations Your power chair is rated for a maximum weight capacity Please refer to the specifications table for this limit MANDATORY Stay within the specified weight capacity of your power chair Exceeding the weight capacity voids your warranty Pride will not be held responsible for injuries and or property damage resulting from failure to observe weight limitations Jv WARNING Do not carry passengers on your power chair Carrying passengers on your power chair may affect the centre of gravity resulting in a tip or a fall J Tyre Inflation If your power chair is equipped with pneumatic tyres you should check or have the air pressure checked regularly Proper inflation pressures will prolong the life of your tyres and help ensure the smooth operation of your power chair WARNING It is important that 2 4 bar 35 psi 240 kPa tyre pressure be maintained in pneumatic tyres at all times Do not underinflate or overinflate your tyres Low pressure may result in loss of control and overinflated tyres may burst Failure to maintain 2 4 bar 35 psi 240 kPa tyre pressure A in pneumatic tyres at all times may result in tyre and or wheel failure VAAN WARNING Inflate your power chair drive tyres from a regulated air source with an available pressure gauge Inflating your tyres from a
16. OWNER S MANUAL Including Model Quantum Dynamo 1107 Pride Mobility Products Ltd www pridemobility com 32 Wedgwood Road Bicester Oxon OX26 4UL SAPETY GUIFD ELIEN ES WARNING A Quantum Rehab Dealer or a qualified technician must perform the initial setup of this power chair and must perform all of the procedures in this manual x 2 The symbols below are used throughout this owner s manual and on the power chair to identify warnings and important information Itis very important for you to read them and understand them completely WARNING Indicates a potentially hazardous condition situation Failure to follow designated procedures can cause either personal injury component damage or malfunction On the product this icon is represented as a black symbol on a yellow triangle with a black border MANDATORY These actions should be performed as specified Failure to perform mandatory actions can cause personal injury and or equipment damage On the product this icon is represented as a white symbol on a blue dot with a white border PROHIBITED These actions are prohibited These actions should not be performed at any time or in any circumstances Performing a prohibited action can cause personal injury and or equipment damage On the product this icon is represented as a black symbol with a red circle and red slash Quick Reference Information Quantum Rehab Dealer Address Phone Number Pur
17. TY SYMBOLS The symbols below are used on the power chair to identify warnings mandatory actions and prohibited actions It is very important for you to read and understand them completely Read and follow the information in the owner s manual Do not allow unsupervised children to play near the power chair while the batteries are charging Maximum seating weight Keep your hands away from the tyres when driving Be aware that loose fitting clothing can become caught in drive tyres Use correct tie down points for controller harness to prevent the harness from getting caught in the drive tyres pinched in the seat frame or damaged when passing through doorways Do not use a cell phone walkie talkie laptop or other radio transmitter while operating Avoid exposure to rain snow ice salt or standing water whenever possible Maintain and store in a clean and dry condition Quantum Dynamo 1107 www quantumrehab com 5 ll SAFETY Removal of grounding prong can create electrical hazard If necessary properly install an approved 3 pronged adapter to an electrical outlet having 2 pronged plug access Do not place your power chair in freewheel mode while on an incline Do not place your power chair in freewheel mode while on a decline Do not lift the mobility product while seated in it Do not lift the mobility product while seated in it Keep tools and other metal objects away from battery terminals Wear sa
18. ackages or power chair accessories do not become caught in lift doors Lift Elevation Products If you will be traveling with your power chair you may find it necessary to use a lift elevation product to aid in transporta tion Pride recommends that you closely review the instructions specifications and safety information set forth by the manufacturer of the lift elevation product before using that product WARNING Never sit on your power chair when it is being used in connection with any JAN type of lift elevation product Your power chair was not designed with such use in mind LS and any damage or injury incurred from such use is not the responsibility of Pride Motor Vehicle Transport Pride recommends that you do not remain seated in your power chair while traveling in a motor vehicle The power chair should be stowed in the boot of a car or in the back of a truck or van with batteries removed and properly secured WARNING Do not sit on your power chair while itis in a moving vehicle transported Batteries should be secured in an upright position and protective caps should be installed on the battery terminals Batteries should not be transported with any flammable or combustible items A WARNING Always be sure your power chair and its batteries are properly secured when it is being Positioning Belts Your authorised Quantum Rehab Dealer therapist s and other healthcare professionals are responsible for determining your require
19. air in a safe manner Quantum Dynamo 1107 www quantumrehab com 15 II SAFETY Alcohol Smoking The power chair user must exercise care and common sense when operating his her power chair This includes awareness of safety issues while under the influence of alcohol or while smoking WARNING Do not operate your power chair while you are under the influence of alcohol as this may impair your ability to operate your power chair in a safe manner N WARNING Pride strongly recommends that you do not smoke cigarettes while seated in your N power chair although the power chair has passed the necessary testing requirements for cigarette a smoking You must adhere to the following safety guidelines if you decide to smoke cigarettes while seated in your power chair m Do not leave lit cigarettes unattended m Keep ashtrays a safe distance from the seat cushions m Always make sure cigarettes are completely extinguished before disposal Electromagnetic and Radio Frequency Interference EMI RFI TN WARNING Laboratory tests have shown that electromagnetic and radio frequency waves can have an adverse affect on the performance of electrically powered mobility vehicles Electromagnetic and Radio Frequency Interference can come from sources such as cellular phones mobile two way radios such as walkie talkies radio stations TV stations amateur radio HAM transmitters wireless computer links microwave signals paging transmitt
20. amaged causing unreliable power chair operation and limited battery life How should I store my power chair and its batteries If you do not use your power chair regularly we recommend maintaining battery vitality by charging the batteries at least once per week If you do not plan on using your power chair for an extended period fully charge the batteries prior to storage Disconnect the battery harnesses and store the power chair in a warm dry environment Avoid temperature extremes such as freezing and excessively hot conditions and never attempt to charge a frozen battery A cold or frozen battery should be warmed for several days prior to recharging What about public transportation AGM and Gel Cell batteries are designed for application in power chairs and other mobility vehicles allowing safe transport on aircraft buses and trains as there is no danger of spillage or leakage We suggest you contact the carrier s ticket counter in advance to determine that carrier s specific requirements What about shipping If you wish to use a freight company to ship your power chair to your final destination repack your power chair in the original shipping container and ship the batteries in separate boxes Quantum Dynamo 1107 www quantumrehab com 33 VII CARE AND MAINTENANCE CARE AND MAINTENANCE The Quantum Dynamo 1107 is a sophisticated power chair Like any motorised vehicle it requires routine maintenance checks You can p
21. asher from the axle See figure 23 Pull the wheel off the axle Remove the nuts and washers from the wheel hub and separate the rim halves See figure 24 Remove the old tube from the pneumatic tyre and replace it with anew tube or replace the entire assembly ifit is a solid tyre Reassemble the rim halves and reinstall the nuts and washers to the wheel hub Slide the wheel back onto the axle Make sure that the key is in the axle slot 10 Reinstall the drive wheel nut and washer onto the axle and tighten 11 Inflate the pneumatic tyres to 2 4 bar 35 psi 240 kPa if equipped with pneumatic tyres 12 Remove the power chair from the blocks OOS ONT d uN Battery Replacement A battery wiring diagram is printed on a decal located inside the battery box lid See VI Batteries and Charging for correct battery specifications AOON MANDATORY Battery posts terminals and related accessories contain lead and lead OKO compounds Wear goggles and gloves when handling batteries and wash hands after Lead oe handling WARNING Do not replace the batteries when the seat is occupied WARNING The batteries on your power chair should only be serviced or replaced bya Quantum Rehab Dealer or a qualified technician JX WARNING Power chair batteries are heavy See specifications table If you are unable to lift that much weight be sure to get help Use proper lifting techniques and avoid lifting beyond your capacity WARNING Do not m
22. ay need ad justment if the following occurs E When coming to a stop your power chair tips forward excessively E The anti tip wheels constantly rub the ground WARNING Consult your Quantum Rehab Dealer before attempting to change the anti tip wheel height Changing the anti tip wheel height affects handling under acceleration Figure 19 Anti Tip Wheel Assembly WARNING The higher you raise the anti I tip wheels the more you increase your A power chair s tendency to tilt forward N while decelerating You can compensate for this by having your Quantum Rehab Dealer make a small adjustment to the pre programmed deceleration setting in the controller or by moving the seat assembly farther to the back of your power chair PROHIBITED Do not remove the anti 9 tip wheels NOTE Each drive tyre must be inflated to 2 4 bar 35 psi 240 kPa if equipped with pneumatic tyres The user must also be seated in the power chair in order to properly adjust the anti tip wheels To adjust the anti tip wheels 1 Loosen nut A See figure 19 2 Remove bolt B 3 Raise or lower the anti tip wheel Each hole is 1 27 cm 0 50 in apart 4 Reinstall bolt B 5 Tighten nutA 6 Raise or lower the other anti tip wheel so that it is at the same height 28 www quantumrehab com Quantum Dynamo 1107 V COMFORT ADJUSTMENTS Positioning Belt Your power chair may be equipped with a positioning belt that can be adjusted for o
23. box The bat tery boxes must be connected in order to charge them See figure 22 WARNING When charging through the IX battery boxes never use greater than AN a 5 amp charging system Failure to comply may result in damage to your power chair Battery Break in To break in new batteries for maximum efficiency 1 Fully recharge any new battery prior to its initial use This brings the battery up to about 90 of its peak performance level 2 Operate your power chair throughout the house and grounds Move slowly at first and do not travel too far until you become accustomed to the controls and break in the batteries 3 Give the batteries another full charge of 8 to 14 hours and operate your power chair again The batteries will now perform at over 90 of their potential 4 Afterfour or five charging cycles the batteries will top off at 100 charge and last for an extended period Figure 21 Battery Charging OFF BOARD CHARGER PORT Figure 22 Battery Boxes Removed from Power Base Quantum Dynamo 1107 www quantumrehab com 31 VI BATTERIES AND CHARGING Frequently Asked Questions FAQs How does the charger work The battery charger takes the standard electrical outlet voltage of 120 VAC alternating current and converts it to 24 VDC direct current The power chair batteries use direct current to run your power chair When the battery voltage is low the charger works harder to charge the batter
24. chase Date NOTE This owner s manual is compiled from the latest specifications and product information available at the time of publication We reserve the right to make changes as they become necessary Any changes to our products may cause slight variations between the illustrations and explanations in this manual and the product you have purchased The latest current version of this manual is available on our website CE ACN 088 609 661 Copyright 2008 Pride Mobility Products Ltd INFMANU3449 Rev C February 2008 CONTENTS k INTRODUCTION ceon E eee ere rete TR te Eee Ere ree ere es 4 le SP a aea E e a E A A a 5 Ui YOUR POWER CHAIR crereeronocioanioenen nea nese ive rm E E a a 17 IV ASSEMBLY DISASSEMBEY sesvete alee neeey 21 Ve COMFORFADJ USTMENTS onien RES 25 Vi BATTERIESAND CHARGING soccrereonieencnsaeneaenau e a s 30 Vil CAREANDMAINTENANC Enronin a a a 34 VILWARRANTY ssroscnnsonienoee a E E E E ee 39 APPENDIX I SPECIFICATTIONS cciscsshasresnicetaeacsioece ye a adie ios ite 40 IMPORTANT NOTICE Attention parents guardians and power chair attendants Please read this manual in its entirety before allowing a minor to operate the Quantum Dynamo 1107 Give close attention to all safety guidelines warnings and cautions contained in this manual Neither this manual nor this power chair is intended for use by a minor without the close supervision of a parent guardian or adult attendant Quantum Dynam
25. e tyres Jerky motion Pulling to one side Bent or broken wheel assemblies Does not power up Powers up but does not move Figure 25 Battery Boxes Corrective Maintenance If the battery condition meter does not light up when you turn on the power Check the harness connections Make sure they are tight Check the circuit breaker Reset it if necessary E Check the battery connections Figure 26 Battery Wiring Diagram Label If the above conditions prove normal you can load test the batteries with a battery load tester These testers are available at automotive parts stores Disconnect both batteries before load testing and follow the directions that come with the load tester If either one of the batteries fails the load test replace both of them If your power chair still does not power up contact your Quantum Rehab Dealer a a eee ae a a ara 38 www quantumrehab com Quantum Dynamo 1107 Vill WARRANTY LIFETIME WARRANTY Structural frame components including platform fork seat post and frame welds TWO YEAR LIMITED WARRANTY Drivetrain including motor and brake EIGHTEEN MONTHS LIMITED WARRANTY Controllers Any attempt to open or dismantle these parts will lead to this warranty being void ONE YEAR LIMITED WARRANTY All electrical parts including battery chargers are covered for one year under warranty Any attempt to open or dismantle these pa
26. er chair Adjust them as necessary See V Comfort Adjustments Check for extreme wear on the anti tip wheels Replace them as necessary Check for drive tyre wear See your Quantum Rehab Dealer for repair Check the castor wheels for wear Replace them as necessary Check the castor forks for damage or fluttering which indicates that they may need to be adjusted or have the bearings replaced See your Quantum Rehab Dealer for repair E Keep your power chair clean and free of foreign material such as mud dirt hair food drink etc Yearly Checks Take your power chair to your Quantum Rehab Dealer for yearly maintenance This helps ensure that your power chair is functioning properly and helps prevent future complications Quantum Dynamo 1107 www quantumrehab com 35 VII CARE AND MAINTENANCE Storage Your power chair should be stored in a dry place free from temperature extremes When storing disconnect the batteries from the power chair See VI Batteries and Charging A WARNING If you fail to store the unit properly the frame can rust and the electronics can be damaged Batteries that are regularly and deeply discharged infrequently charged stored in extreme temperatures or stored without a full charge may be permanently damaged causing unreliable performance and limited service life It is recommended that you charge the batteries periodically throughout periods of prolonged storage to ensure proper performance
27. erform some of these checks but others require assistance from your Quantum Rehab Dealer Preven tive maintenance is very important If you follow the maintenance checks in this section as scheduled you can help ensure that your power chair gives you years of trouble free operation If you have any doubt as to your power chair s care or operation contact your Quantum Rehab Dealer 4 re A WARNING Do not service the power chair when the seat is occupied C Your power chair like most electrical equipment is susceptible to damage from the elements Avoid damp areas of any kind A Sa WARNING Direct or prolonged exposure to water or dampness could cause the power chair to S malfunction electronically and mechanically Water can cause electrical components to corrode ASSA as a and the chair s frame to rust Power chairs should be examined periodically for signs of corrosion f caused by water exposure bodily fluid exposure or incontinence Damaged components should 4 be replaced or treated immediately Should your power chair come in contact with water 1 Dry your power chair as thoroughly as possible with a towel 2 Allow your power chair to sit ina warm dry place for 12 hours to allow unseen water to evaporate 3 Check the joystick operation and the brakes before using your power chair again 4 Ifany inconsistencies are found take your power chair to your authorised Quantum Rehab Dealer Power chairs that are
28. ers and medium range mobile transceivers used by emergency vehicles In some cases these waves can cause unintended movement or damage to the control system Every electrically powered mobility vehicle has an immunity or resistance to EMI The higher the immunity level the greater the protection against EMI This product has been tested and has passed at an immunity level of 20 V m WARNING Be aware that cell phones two way radios laptops and other types of radio transmitters may cause unintended movement of your electrically powered mobility vehicle due to EMI Exercise caution when using any of these items while operating your mobility vehicle and avoid coming into close proximity of radio and TV stations WARNING The addition of accessories or components to the electrically powered mobility vehicle can increase the susceptibility of the vehicle to EMI Do not modify your power chair in any way A not authorised by Pride WARNING The electrically powered mobility vehicle itself can disturb the performance of other electrical devices located nearby such as alarm systems NOTE For further information on EMI RFI go to the Resource Center on www pridemobility com If unintended motion or brake release occurs turn your power chair off as soon as it is safe to do so Contact your Quantum Rehab Dealer to report the incident e aa a 16 www quantumrehab com Quantum Dynamo 1107 lll YOUR POWER CHAIR THE QUANTUM DYNAMO 1107
29. ert objects through these slots WARNING If your battery charger has not been tested and approved for outdoor use then do not expose it to adverse or extreme weather conditions If the battery charger is exposed to adverse orextreme weather conditions then it must be allowed to adjust to the difference in environmental RA conditions before use indoors Refer to the manual supplied with the battery charger for more amp information 30 www quantumrehab com Quantum Dynamo 1107 VI BATITERIES AND CHARGING To charge the batteries using the off board charger 1 Position the front of your power chair next to a stan dard electrical outlet 2 Be certain the controller power is turned off 3 Plug the off board charger into the off board charger programming socket on the controller See figure 21 4 Plug the off board charger into the electrical outlet NOTE If it is a Pride off board charger then there are two lights in it The red light indicates that power to the off board charger is on The green light indi cates that the batteries are fully charged If it is not a Pride off board charger then follow the instructions supplied by the manufacturer 5 When the batteries are fully charged unplug the off board charger from the electrical outlet and then from the controller NOTE You can remove both battery boxes from the power base and charge them using the off board charger port located on the front battery
30. fety goggles 6 www quantumrehab com Quantum Dynamo 1107 ll SAFETY EMI RFI This product has been tested and passed at an immunity level of 20 V m Explosive conditions exist A Corrosive chemicals contained in battery 7 z hs SLA AGM Use only AGM or Gel Cell batteries to reduce the risk of leakage or explosive conditions Do not connect an extension lead to the AC DC converter or the battery charger Battery Set Configuration Positive Red Terminal Post Negative Black Terminal Post Connect Red wire to Red Positive Terminal Post Connect Black wire to Black Negative Terminal Post S M x 3 c 2 pee ssr Do not use batteries with different amp hour Ah capacities Do not mix old and new batteries Always replace both batteries at the same time Quantum Dynamo 1107 www quantumrehab com 7 ll SAFETY Battery charger for indoor use only Disposal and recycling Contact your authorised Quantum Rehab Dealer for information on proper disposal and recycling of your Pride product and its packaging Locked and in drive mode Place unit on level ground and stand to one side when changing from drive mode to freewheel mode or freewheel mode to drive mode Unlocked and in freewheel mode Pb Contains Lead SS ae acs ae a a mY www quantumrehab com Quantum Dynamo 1107 0 0 II SAFETY SAFETY MANDATORY Do no
31. harge and then accept a relatively quick recharge AGM and Gel Cell batteries should be charged as often as possible They do not have a memory like nickel cadmium batteries We work closely with our battery manufacturer to provide a battery that best suits your power chair s specific demands Fresh batteries arrive regularly at Pride and are promptly shipped with a full charge During shipping the batteries encoun ter temperature extremes that may influence initial performance Heat robs the charge from the battery and cold slows the power available and extends the time needed to recharge the battery just as with a car battery It might take a few days for the temperature of the battery to stabilise and adjust to its new ambient temperature More importantly it will take a few charging cycles a partial drain then a full recharge to establish the critical chemical balance that is essential to the battery s peak performance and long life It will be well worth it to take the time to break in your battery properly NOTE The useful life of a battery is quite often a reflection of the care it receives How can I ensure maximum battery life A fully charged deep cycle battery will provide reliable performance and extended battery life Keep your power chair s batteries fully charged whenever possible Batteries that are regularly and deeply discharged infrequently charged or stored without a full charge may be permanently d
32. is product or remove or render inoperable or unsafe any guards shields or other safety features of this product fail refuse or neglect to install any retrofit kits from time to time provided by Pride to enhance or preserve the safe use of this product SHIPPING AND DELIVERY Before using your power chair make sure your delivery is complete as some components may be individually packaged If you do not receive a complete delivery please contact your authorised Quantum Rehab Dealer immediately Where damage has occurred during transport either to the packaging or content please contact the delivery company respon sible INFORMATION EXCHANGE We want to hear your questions comments and suggestions about this manual We would also like to hear about the safety and reliability of your new power chair and about the service you received from your authorised Quantum Rehab Dealer Please notify us of any change of address so we can keep you apprised of important information about safety new products and new options that can increase your ability to use and enjoy your power chair Please feel free to contact us at the address below Pride Mobility Products Ltd 32 Wedgwood Road Bicester Oxon OX26 4UL NOTE If you ever lose or misplace your product registration card or your copy of this manual contact us and we will be glad to send you a new one immediately 4 www quantumrehab com Quantum Dynamo 1107 Whites Se Aho ET Y PRODUCT SAFE
33. is where the controller plugs into the power base Each controller uses a different type of cable connector If the controller has a power module in the power base the connector is a small communi cations type connector Regardless of controller type the cable must be secured to the seat assembly and not allowed to drag on the floor pe a ee ae a a a aa a 18 www quantumrehab com Quantum Dynamo 1107 lll YOUR POWER CHAIR Battery Harness Connector This is where the controller connects to the battery boxes Main Circuit Breaker located on rear battery box The main circuit breaker is a safety feature built into your power chair When the batteries and the motors are heavily strained e g from excessive loads the main circuit breaker trips to prevent damage to the motors and the electronics If the circuit trips allow your power chair to rest for approximately one minute Next push in the circuit breaker button turn on the controller and continue normal operation If the main circuit breaker continues to trip repeatedly contact your Quantum Rehab Dealer Controller Power Module The controller power module enables the controller to communicate with the batteries and the motors This feature is used with modular controller systems only Motor Connectors This is where the motors connect to the controller power module BATTERY HARNESS CONNECTOR CONTROLLER CONNECTOR MOTOR CONNECTOR 3 A 4 4 4 E 3 Ji E mA
34. ix or match new and old batteries If you encounter a situation where one battery needs to be replaced then replace both batteries Refer to the specifications table in this manual and the manual supplied with the battery charger for recommended type and capacities Quantum Dynamo 1107 www quantumrehab com 37 VII CARE AND MAINTENANCE To replace the batteries 1 Turn off the power to the controller 2 Make sure that the power chair is in drive mode 3 Remove the battery boxes See IV Assembly Disas sembly Disconnect the wiring harnesses from the batteries Remove the batteries from the battery boxes Place new batteries in the battery boxes See figure 25 Reconnect the battery harnesses according to the bat tery wiring diagram label See figure 26 So Sue N WARNING Make sure you tighten the fasteners so that the connections are secure 8 Reinstall the battery boxes onto the power base Make sure that the battery box latches are in the up locked position 9 Charge the batteries See VI Batteries and Charging een When to See Your Quantum Rehab Dealer for Service The following symptoms could indicate a serious problem with your power chair If necessary contact your Quantum Rehab Dealer When calling have the model number serial number nature of the problem and the error code if avail able Motor noise Frayed harnesses Cracked or broken connectors Uneven wear on any of th
35. ly you are turning uneven road surfaces inclined road surfaces riding from an area of low traction to an area of high traction such as passing from a grassy area to a paved area especially at high speed while turning and abrupt directional changes High cornering speeds are not recommended If you feel that you may tip over in a corner reduce your speed and steering angle i e lessen the sharpness of the turn to prevent your power chair from tipping TA WARNING When cornering sharply reduce your speed and maintain a stable centre of gravity 4 This greatly reduces the possibility of a tip or fall Always exercise common sense when cornering Quantum Dynamo 1107 www quantumrehab com 11 II SAFETY Public Streets and Roadways WARNING You should not operate your power chair on public streets and roadways Be aware VAN that it may be difficult for traffic to see you when you are seated on your power chair Obey all local pedestrian traffic rules Wait until your path is clear of traffic and then proceed with extreme caution Outdoor Driving Surfaces Your power chair is designed to provide optimum stability under normal driving conditions dry level surfaces composed of concrete blacktop or tarmac However Pride recognises that there will be times when you will encounter other surface types For this reason your power chair is designed to perform admirably on packed soil grass and gravel Feel free to use your
36. ment for a positioning belt in order to operate your power chair safely Typically the positioning belt is not designed for use as a restraining device in a motor vehicle Positioning belts should be installed as detailed in this manual See V Comfort Adjustments Once installed the belt should be placed across the pelvis as determined by the user s healthcare dealer Anchor points of the positioning belts should be located so that a projected side view angle of the pelvis is between 30 75 of horizontal depending on the user s weight posture and seat cushion thickness i WARNING If you require a positioning belt to safely operate your power chair make sure it is A fastened securely in order to reduce the possibility of a fall from the power chair 4 WARNING The positioning belt is not designed for use as a seat belt in a motor vehicle Quantum Dynamo 1107 www quantumrehab com 13 II SAFETY Batteries In addition to following the warnings below be sure to comply with all other battery handling information For more information about your power chair s batteries see VI Batteries and Charging Lead MANDATORY Battery posts terminals and related accessories contain lead and lead compounds Wear goggles and gloves when handling batteries and wash hands after handling WARNING Power chair batteries are heavy See specifications table If you are unable to lift that much weight be sure to get hel
37. moval of grounding prong can create electrical hazard If necessary properly U Y install an approved 3 pronged adapter to an electrical outlet having 2 pronged plug access S amp PROHIBITED Never use an extension lead to plug in your battery charger Plug the charger directly Yy into a properly wired standard electrical outlet are charging Pride recommends that you do not charge the batteries while the power chair is PROHIBITED Do not allow unsupervised children to play near the power chair while the batteries X 7 occupied N MANDATORY Read the battery charging instructions in this manual and in the manual supplied Gy with the battery charger before charging the batteries WARNING Explosive gases may be generated while charging the batteries Keep the power chair and battery charger away from sources of ignition such as flames or sparks and provide adequate ventilation when charging the batteries WARNING You must recharge your power chair s batteries with the supplied off board charger Do not use an automotive type battery charger WARNING Inspect the battery charger wiring and connectors for damage before each use Contact JN your Quantum Rehab Dealer if damage is found WARNING Do not attempt to open the battery charger case If the battery charger does not appear to be working correctly contact your Quantum Rehab Dealer WARNING If the battery charger is equipped with cooling slots then do not attempt to ins
38. n unregulated air source could overinflate them resulting in a burst tyre Incline Information More and more buildings have ramps with specified degrees of inclination designed for easy and safe access Some ramps may have turning switchbacks 180 degree turns that require you to have good cornering skills on your power chair E Proceed with extreme caution as you approach the downgrade of a ramp or other incline E Take wide swings with your power chair s front wheels around any tight corners If you do that the power chair s rear wheels will follow a wide arc not cut the corner short and not bump into or get hung up on any railing corners E When driving down a ramp keep the power chair s speed adjustment set to the slowest speed setting to ensure a safely controlled descent E Avoid sudden stops and starts When climbing an incline try to keep your power chair moving If you must stop start up again slowly and then accelerate cautiously When driving down an incline set your power chair to the slowest speed setting and drive in the forward direction only If your power chair starts to move down the incline faster than you anticipated or desired allow it to come to a complete stop by releasing the joystick then push the joystick forward slightly to ensure a safely controlled descent WARNING When on any sort of an incline or decline never place the power chair in S SY freewheel mode while seated on it or standing next to i
39. nd angle foot platform height and angle and controller position NOTE If your power chair is equipped with a Synergy Seat or a Synergy TRU Balance Power Positioning System refer to the supplemental information provided in separate manuals Information regarding armrest adjustment is also provided in a separate manual WARNING The centre of gravity of your seating system was factory set to a position that meets the needs of the demographic majority of users Your Quantum Rehab Dealer has evaluated your seating system and made any necessary adjustments to suit your specific requirements Do not change your seating configuration without first contacting Pride Mobility Products or your Quantum Rehab Dealer IN WARNING Some power chair components are heavy You may need assistance to lift or carry them Please refer to the specifications table for specific component weights before you disassemble the power chair WARNING Remove the occupant from the power chair before making any adjustments You may need the following to make comfort adjust ments E metric standard socket set and ratchet E adjustable spanner E thread lock Seat Height and Seat Angle Adjustment You can change the seat height by either raising or lowering the four seat towers attached to the seat base To change the seat height 1 Remove the T handle ball detent pins that secure the seat base to the power base See figure 14 2 Raise or lower the seat
40. ntroller from the power base 3 Cut any wire ties that attach the controller cable to the armrest 4 Loosen the mounting screws in the mounting block See figure 15 5 Remove the mounting block from the armrest 6 Place the mounting block on the other armrest and tighten the mounting screws 7 Use a wire tie to secure the controller cable to the armrest 8 Plug the controller cable into the power base See figure 6 Foot Platform Height Adjustment The foot platform height is easily adjusted to different heights in 1 27 cm 0 50 in increments To raise or lower the foot platform 1 Remove the quick release fasteners from the foot platform bracket See figure 16 2 Raise or lower the foot platform to the desired height 3 Reinstall the quick release fasteners into the foot platform bracket and tighten 26 www quantumrehab com MOUNTING SCREWS MOUNTING BLOCK y SETSCREWS PLATFORM BRACKET Figure 16 Foot Platform Adjustment Quantum Dynamo 1107 V COMFORT ADJUSTMENTS Foot Platform Depth Adjustment To adjust the foot platform depth 1 Remove the quick release fasteners from the foot platform bracket See figure 16 2 Movethe foot platform in or out to the desired depth 3 Reinstall the quick release fasteners into the foot platform bracket and tighten Quick Release Fasteners The foot platform is attached to the power base with two quick release fasteners Each quick release fastener c
41. o 1107 www quantumrehab com lI INTRODUCTION SAFETY WELCOME to Quantum Rehab a division of Pride Mobility Products Corporation Pride The power chair you have purchased combines state of the art components with safety comfort and styling in mind We are confident that these design features will provide you with the conveniences you expect during your daily activities Once you understand how to safely operate and care for your power chair it should give you years of trouble free operation and service Read and follow all instructions warnings and notes in this manual before attempting to operate your power chair for the first time You must also read all instructions warnings and notes contained in any supplemental instructional booklets for the controller front riggings and or seating system that accompanied your power chair before initial operation Your safety depends upon you as well as your dealer carer or healthcare professional in using good judgement If there is any information in this manual which you do not understand or if you require additional assistance for setup or operation please contact your authorised Quantum Rehab Dealer Failure to follow the instructions in this manual and those located on your power chair can lead to personal injury and or damage to the power chair and may void the warranty PURCHASER S AGREEMENT By accepting delivery of this product you promise that you will not change alter or modify th
42. off of lifts up and down ramps and over moderate terrain Below are some precautions tips and other safety considerations that will help you become accustomed to operating your power chair safely Modifications Pride has designed and engineered your power chair to provide maximum mobility and utility A wide range of accessories is available from your Quantum Rehab Dealer to further customise your power chair to better suit your needs and or preferences However under no circumstances should you modify add remove or disable any feature part or function of your power chair TN ag f WARNING Do not modify your power chair in any way not authorised by Pride Do not use accessories if they have not been tested or approved for Pride products Pre Ride Safety Check Get to know the feel of your power chair and its capabilities Pride recommends that you perform a safety check before each use to make sure your power chair operates smoothly and safely Perform the following inspections prior to using your power chair Check for proper tyre inflation Maintain but do not exceed 2 4 bar 35 psi 240 kPa in each tyre if equipped with pneumatic tyres Check all electrical connections Make sure they are tight and not corroded Check all controller connections to the power base Make sure they are secured properly Check the brakes See VII Care and Maintenance Check battery charge See VI Batteries and Charging N
43. on sists of a bolt a lever and a nut See figure 17 The lever has acam on the end that allows it to clamp into place The quick release fastener has two states clamped and unclamped When the lever is open the quick release fastener is unclamped When the lever is closed the quick release fastener is clamped To clamp the quick release fastener 1 Make sure the lever is in the open position 2 Turn the nut clockwise until itis snug 3 Rotate the lever until it is in the fully closed position NOTE If the lever will not rotate to the fully closed position then turn the nut anticlockwise one quar ter or one half turn Foot Platform Angle Adjustment You can adjust the angle of the foot platform with a hex key See figure 18 To adjust the foot platform angle 1 Locate the setscrew on the underside of the foot plat form 2 Turn the setscrew to raise or to lower the front of the foot platform LEVER OPEN LEVER FULLY CLOSED UNCLAMPED Figure 18 Underside of Foot Platform Quantum Dynamo 1107 www quantumrehab com CLAMPED V COMFORT ADJUSTMENTS Anti Tip Wheels The anti tip wheels are designed to give your power chair increased stability on rough surfaces The anti tip wheels are preset at the factory for smooth surfaces or indoor use only If you plan on using your power chair on rough sur faces it may be necessary to adjust the anti tip wheels to better suit your needs The anti tip wheels m
44. ot frayed cut or has any wires exposed See your Quantum Rehab Dealer if there is a problem E Check for flat spots on solid tyres Flat spots could adversely affect stability E Inspect the armrests for loose hardware stress points or damage See your Quantum Rehab Dealer if there is a problem Weekly Checks E Disconnect and inspect the controller battery door Look for corrosion Contact your Quantum Rehab Dealer if necessary E Ensure that all parts of the controller system are securely fastened to your power chair Do not overtighten any screws E Check for proper tyre inflation There should be 2 4 bar 35 psi 240 kPa in each tyre If a tyre does not hold air see your Quantum Rehab Dealer for replacement of the tube Check the brakes This test should be carried out on a level surface with at least 1 metre 3 ft of clearance around your power chair To check the brakes 1 Turnon the controller and turn down the speed level of your power chair 2 After one second check the battery condition meter Make sure that it remains on 3 Slowly push the joystick forward until you hear the electromagnetic brakes click Immediately release the joystick You must be able to hear each electromagnetic brake operating within a few seconds of joystick movement Repeat this test three times pushing the joystick rearward then left and then right Monthly Checks Check that the anti tip wheels do not rub the ground when you operate the pow
45. p Use proper lifting techniques and avoid lifting beyond your capacity WARNING Always protect the batteries from freezing and never charge a frozen battery Charging a frozen battery may result in damage to the battery E WARNING Connect your battery harnesses in the proper manner RED cables must be connected to positive battery terminals posts BLACK cables must be connected to negative battery terminals posts Protective caps should be installed over all battery terminals REPLACE cables immediately if damaged Removable Parts IX ff WARNING Do not attempt to lift or move a power chair by any of its removable parts including the armrests seat foot riggings controller and shrouds Preventing Unintended Movement N WARNING If you anticipate being seated in a stationary position for an extended period of time AN turn off the power This will prevent unexpected motion from inadvertent joystick contact This will also eliminate the possibility of unintended chair movement from electromagnetic EM sources E Reaching and Bending Never reach lean or bend while driving your power chair If itis absolutely necessary to reach lean or bend while seated on your power chair it is important to maintain a stable centre of gravity and keep the power chair from tipping Pride recommends that the power chair user determine his her personal limitations and practice bending and reaching in the presence of a qualified
46. perator comfort See figure 20 The positioning belt is designed to support the operator so that he she does not slide down or forward in the seat The positioning belt is not designed for use as a restraining device To install the positioning belt l 2 Remove the rearmost screw that holds the seat hinge to the seat base on both the left and right seat hinges Insert the screw through the supplied washer through the positioning belt and into the seat base for each side of the power chair seat Tighten both screws To adjust the positioning belt for operator comfort l Once seated insert the metal tab on one side of the belt into the plastic housing on the opposite side until you hear a click See figure 20 Pull the excess strap attached to the metal tab until it is secure but not so tight as to cause discomfort To release the positioning belt 1 Press the push button mechanism on the plastic housing MANDATORY Make sure the positioning belt is properly secured to the power chair and is adjusted for operator comfort before each use MANDATORY Inspect the positioning A belt for loose or damaged parts before each use of the power chair If you discover a problem contact your Quantum Rehab Dealer for maintenance and repair Figure 20 Positioning Belt Adjustment Quantum Dynamo 1107 www quantumrehab com 29 VI BATTERIES AND CHARGING BATTERIES AND CHARGING The Quantum Dynamo 1107 use
47. rts will lead to this warranty being void BATTERIES Batteries are covered by a twelve month warranty from the original manufacturer NOT COVERED UNDER WARRANTY The following parts are classed as wear items which may under normal wear and tear require replacing These items are not therefore covered under warranty tyres positioning belts bulbs upholstery plastic shrouds motor brushes fuses and batteries Warranty will also be refused if damage is deemed to have been caused through misuse or accident for which Pride Mobility Products Ltd cannot be deemed responsible NOTE Pride Mobility Products Ltd provides parts only under warranty Your Quantum Rehab Dealer is responsible for labour and service Please contact your Quantum Rehab Dealer for information about these services and for any applicable charges a SSS Quantum Dynamo 1107 www quantumrehab com 39 APPENDIX SPECIFICATIONS QUANTUM DY NAMO 1107 SPECIFICATIONS Suspension Active Trac Drive Wheels 25 4 cm 10 in pneumatic or solid available Castor Wheels 15 25 cm 6 in solid rear mounted Anti tip Wheels 12 7 cm 5in solid front mounted Maximum Speed Up to 7 25 km h 4 5 mph Range Up to 23 82 km 14 8 miles Brakes Intelligent Braking electronic regenerative disc park brake Ground Clearance 2 See figure 26 Turning Radius See figure 26 Overall Size Length See figure 26 Width See figure 26 Dri
48. s two long lasting 12 volt deep cycle batteries These batteries are sealed and maintenance free Since they are sealed there is no need to check the electrolyte fluid level Deep cycle batteries are designed to handle a longer and deeper discharge Though they are similar in appearance to automotive batteries they are not interchangeable Automotive batteries are not designed to handle a long deep discharge and also are unsafe for use in power chairs Pb aN MANDATORY Battery posts terminals and related accessories contain lead and lead es compounds Wear goggles and gloves when handling batteries and wash hands after XS handling WARNING Always use two batteries of the exact same type chemistry and amp hour a Ah capacity Refer to the specifications table in this manual and in the manual supplied with the battery charger for recommended type and capacities ff NI WARNING Contact your Quantum Rehab Dealer if you have any questions regarding 4 N the batteries in your power chair Charging the Batteries The battery charger is essential in providing long life for your power chair batteries It is designed to optimise your power chair s performance by charging the batteries safely quickly and easily The battery charging system consists of the battery charger and the charger circuit fuse The battery charger is only functional when the charger power lead is plugged into an electrical outlet See figure 7 K gt PROHIBITED Re
49. seat as they may cause the seat to become slippery or dry out and crack Use soapy water and dry the seat thoroughly Wheel Replacement If you have pneumatic tyres and you have a flat tyre you can replace the tube If your chair is equipped with a solid tyre insert then you must replace the entire wheel assembly Replacement tyres tubes and wheel assemblies are readily avail able through your Quantum Rehab Dealer WARNING The wheels on your power chair should only be serviced or replaced by a Quantum Rehab Dealer or a qualified technician J WARNING Be sure that the controller s power is turned off and the power chair is not in freewheel 4 mode before performing this procedure WARNING When changing a tyre remove only the centre lug nut and washer then remove the wheel If any further disassembly is required deflate the tyre completely or it may explode 36 www quantumrehab com Quantum Dynamo 1107 CARE AND MAINTENANCE FRONT RIM HALF WARNING Completely deflate the tyre before attempting repair DRIVE WHEEL WASHER WASHERS oe ow we a Figure 23 Quantum Dynamo 1107 Drive Wheel Figure 24 Quantum Dynamo 1107 Drive Wheel Disassembled Follow these easy steps for a quick and safe repair for both pneumatic and solid tyres Turn off the power to the controller Set the power chair up on blocks If you are changing a pneumatic tyre completely deflate it before removing the wheel Remove the drive wheel nut and w
50. steeper than 8 7 5 may put your power chair in an unstable position and cause it to tip Figure 1 Maximum Safe Slope Ascending and Descending Freewheel Mode Your power chair is equipped with two manual freewheel levers to allow for manual manoeuvrability by a trained attendant For more information about how to place your power chair into and out of freewheel mode see III Your Power Chair WARNING Do not use your power chair in freewheel mode without an attendant present A WARNING Do not attempt to personally place your power chair in freewheel mode while seated on it Ask an attendant for assistance if necessary WARNING Do not place your power chair in freewheel mode while on an incline or S EN decline This could cause the chair to roll uncontrollably on its own Braking Information Your power chair is equipped with two powerful brake systems E Regenerative uses electricity to rapidly slow the vehicle when the joystick returns to the centre stop position E Disc Park Brake activates mechanically after regenerative braking slows the vehicle to near stop or when power is removed from the system for any reason Cornering Information While your power chair is equipped with front and rear castor wheels excessively high cornering speeds can still create the possibility of tipping Factors which affect the possibility of tipping include but are not limited to cornering speed steering angle how sharp
51. t WARNING When climbing an incline do not zigzag or drive at an angle up the face of the incline Drive your power chair straight up the incline This greatly reduces the possibility of a tip ora fall Always exercise extreme caution when negotiating an incline WARNING You should not travel up or down a potentially hazardous incline i e areas covered with snow ice cut grass or wet leaves A WARNING Never travel down an incline rearward Doing so may cause the power chair to tip Always exercise extreme caution when negotiating an incline WARNING If your power chair is equipped with a reclining seatback do not attempt to negotiate inclines with the seat in a reclined position Do not attempt to negotiate obstacles with the seat in a reclined position unless an attendant is present to help stabilise the chair Failure to heed could result in the power chair tipping over 10 www quantumrehab com Quantum Dynamo 1107 le SAFET Y in figure 1 do not under any circumstances exceed the incline guidelines or any other A WARNING Even though your power chair is capable of climbing slopes greater than those illustrated K specifications presented in this manual Doing so could cause instability in your power chair Pride recommends that the maximum slope of an incline you attempt to safely ascend or descend on your power chair does not exceed 8 7 5 See figure 1 N WARNING Any attempt to climb or descend a slope
52. t operate your new power chair for the first time without completely reading and understanding this owner s manual Your power chair is a state of the art life enhancement device designed to increase mobility Pride provides an extensive variety of products to best fit the individual needs of the power chair user Please be aware that the final selection and purchasing decision regarding the type of power chair to be used is the responsibility of the power chair user who is capable of making such a decision and his her healthcare professional i e medical doctor physical therapist etc The contents of this manual are based on the expectation that a mobility device expert has properly fitted the power chair to the user and has assisted the prescribing healthcare professional and or the Quantum Rehab Dealer in the instruction process for the use of the product There are certain situations including some medical conditions where the power chair user will need to practice operating the power chair in the presence of a trained attendant A trained attendant can be defined as a family member or care professional specially trained in assisting a power chair user in various daily living activities As you begin using your power chair during daily activities you will probably encounter situations in which you will need some practice Simply take your time and you will soon be in full and confident control as you manoeuvre through door ways on and
53. the foot platform or remove the leg rests See figures 12 19 or 20 Flip down the battery box latches on each side of the power base See figure 13 Slide the battery boxes back and off of the power base Flip up the centre section latch See figure 13 Rotate the centre section forward Grab aside section by the side frame handle See figure 13 10 Lift the side section up and off of the centre section 11 Grab the other side section by the side frame handle 12 Lift the second side section up and off of the centre section CHONDA RWNS NOTE Perform the disassembly steps in reverse order to assemble the power chair NOTE During assembly make sure the battery box latches are in the up locked position and the centre section latch is in the down locked position REAR BATTERY BOX FRONT BATTERY BOX RIGHT FRAME SECTION FOOT PLATFORM CENTRE SECTION FOOT PLATFORM RELEASE BUTTON Figure 12 Quantum Dynamo 1107 Power Base Parts Quantum Dynamo 1107 www quantumrehab com 23 IV ASSEMBLY DISASSEMBLY CENTRE SECTION LATCH BATTERY BOX LATCH BATTERY BOX LATCH UNLOCKED Figure 13 Quantum Dynamo 1107 Battery Box Removal and Frame Separation 24 www quantumrehab com Quantum Dynamo 1107 V COMFORT ADJUSTMENTS COMFORT ADJ USTMENTS After becoming familiar with your power chair s operation you may find the need to make some adjustments to increase your comfort These adjustments include seat height a
54. vetrain Two motor mid wheel drive Batteries Two 12 volt U 1 batteries Battery Charger 5 amp off board power cube Weight Capacity 72 5 kg 11 stone 160 Ibs Component Weights Base 50 8 kg 112 Ibs Right Section 19 5 kg 43 Ibs Left Section 19 5 kg 43 Ibs Centre Section 7 7 kg 17 lbs Battery Boxes 2 kg 4 5 lbs each Synergy Seat 18 kg 39 5 lbs Batteries 11 11 kg 24 5 lbs each 3 Varies with base model user weight terrain type battery amp hour rating Ah battery charge battery condition motors controller type tyre type and tyre condition This specification can be subject to a variance of or 10 Due to manufacturing tolerances and continued product improvement this specification can be subject to a variance of or 3 AGM or Gel Cell type required See VI Batteries and Charging NOTE All specifications subject to change without notice 40 www quantumrehab com Quantum Dynamo 1107 U Z O H lt O LL O Lu a U APPENDIX TURNING RADIUS 92 71 cm 36 5 with foot platform 92 cm 36 25 WIDTH 60 33 cm 23 375 CY GROUND CLEARANCE Figure 26 Quantum Dynamo 1107 Dimensions and Ground Clearance www quantumrehab com 41 Quantum Dynamo 1107 OEEO aa a 42 www quantumrehab com Quantum Dynamo 1107 Quality Control Quantum Dynamo 1107 Inclusion of all Parts Joystick Serial Number Controller
55. y As the battery voltage approaches full charge the charger does not work as hard to complete the charging cycle When the battery is fully charged the amperage from the charger is nearly at zero This is how the charger maintains a charge but does not overcharge the battery Can I use a different battery charger You should use the charger supplied with the power chair It is the safest most efficient tool to charge the batteries We do not recommend using other types of chargers e g an automotive battery charger NOTE Your power chair s charger will not operate after the batteries have been discharged to nearly zero voltage If this happens call your Quantum Rehab Dealer for assistance How often must I charge the batteries Many factors come into play when deciding how often to charge the batteries You may use your power chair all day ona daily basis or you may not use it for weeks at a time E Daily Use If you use your power chair on a daily basis charge the batteries as soon as you are finished using your power chair Your power chair will be ready each morning to give youa full day s service It is recommended that you charge the batteries 8 to 14 hours after daily use E Infrequent Use If you use your power chair infrequently once a week or less you should charge the batteries at least once per week for 12 to 14 hours NOTE Keep your batteries fully charged and avoid deeply discharging your batteries Do not charge the
Download Pdf Manuals
Related Search
Related Contents
User Manual IMPORTANT: Please read carefully before installation and TAFCO WINDOWS NU2-006S-I Installation Guide Dodge JR41 User's Manual Lincoln Electric MULTI-SOURCE SVM155-A User's Manual 400-230-000-C (PB112-12VDC) ENG.fm [ 低騒音プレート ] 詳細情報 Rainbow2 IP Phone User Manual Manuel utilisateur RADEMACHER D Einbau- und Copyright © All rights reserved.