Home
TP T 15HD 45 and TP T A 45
Contents
1. o o eeneneneneeeenenenenernsnerersrernrsrsrernrnrrsrerernrrsrsrens A 2 Included Parts EE A 7 EECHER eege A 7 All trademarks mentioned in this manual are the properties of their respective owners TP T 15HD 45 and TP T A 45 e Table of Contents TOC i Table of Contents cont d TOC ii TP T 15HD 45 and TPT A 45 e Table of Contents 2 TPT 15HD 45 and TPT A 45 Chapter One Introduction Features Introduction Introduction The Extron TP T 15HD 45 twisted pair transmitter and the matching TP T A 45 audio input module provide a system for sending RGBHV RGBS RGsB component composite or S video and stereo audio signals over an Extron Skew Free A V UTP or CAT 5 5e 6 UTP cable to a compatible TP or VTR receiver An external 12 VDC power supply provides power to both the TP T 15HD 45 and the TP T A 45 The TP T A 45 inputs unbalanced audio through a 3 5 mm stereo phono jack and outputs digital audio to the TP T 15HD 45 transmitter The following table specifies the maximum recommended transmission distances between the TP T 15HD 45 transmitter and compatible Extron receivers at 60 Hz The maximum recommended distances for high quality HQ and variable quality VQ transmissions are shown in the table below Recommended Video maximum range format and to VIR Series resolution and TP R 15HD A Recommended maximum range to all other Extron receivers Composite S video Component 640 x 480 800 x 600
2. Introduction cont d 1 4 TP T 15HD 45 and TP T A 45 e Introduction 3 TPT 15HD 45 and TPT A 45 Chapter Two Installation Rear Panel Connectors Front Panel Connectors and Indicators Cabling and Setup Installation Rear Panel Connectors Extron TPT 15HD 45 12 VDC _ 5A MAX AUDIO AUDIO Extron D TPT A 45 AUDIO AUDIO 12 VDC eil _ 5A MAX TP T 15HD 45 TPTA4S Figure 2 1 Rear panel views Power input captive screw connector Connect the included 12 VDC external power supply to the 2 pole female direct insertion captive screw connector NOTE The TP T 15HD 45 and the TP T A 45 share a single power supply Neither can be remotely powered by the attached receiver A A mo Power Supply Output Cord WARNING CAUTION PO em mmm CR 5A max SECTION A A _ Captive Screw Direct Insertion Connector The two power supply leads must be kept separated while the power supply is plugged into an electrical outlet Remove power before wiring Power supply voltage polarity is critical Incorrect voltage polarity can damage the power supply and the transmitter Identify the power cord negative lead by the ridges on the side of the cord When stripping the wire ends please note that stripped wire ends that are too short may pull out from the captive screw connector and stripped wire ends that are too long could possibly touch and short together 2 2
3. Specifications Video video models Number signal iwpe 1 2 or 4 sets of proprietary analog signals Connectors IP DOD Ahrori 1 8 pin spring force captive wire connector All other models 1 2 or 4 shielded RJ 45 female Video input video models Number signal type TP T 15HD A TP T 15HD 45 1 analog RGBHV RGBS RGsB component video or S video or 1 S video and 1 NTSC PAL SECAM composite video from a single source or 3 NTSC PAL composite video from a single source TP T 15HD AV oc 1 analog RGBHV RGBS RGsB component video or S video or 1 S video and 1 NTSC PAL SECAM composite video from a single source or 3 NTSC PAL SECAM composite video from a single source and 1 NTSC PAL SECAM composite video TP T BNC DAG 1 analog RGBHV RGBS RGsB component video or S video or 1 S video and 1 NTSC PAL SECAM composite video from a single source or 3 NTSC PAL SECAM composite video from a single source NOTE These products accept component video with bi level sync only Connectors TP T 15HD A TP T 15HD 45 1 15 pin HD female Mac and Sun SGI to VGA adapters are available TP T 15HD AV E 1 15 pin HD female Mac and Sun SGI to VGA adapters are available 1 RCA female TP T BNC DA4 iegegeeieeegeg 5 BNC female A 2 TP T 15HD 45 and TP T A 45 e Reference Information Nominal Vel arssnsenserenes 1 Vp p for Y of component video and S video and for composite video 0 7 Vp p for RGB and for R Y and B Y
4. Power disconnection e To remove power from the equipment safely remove all power cords from the rear of the equipment or the desktop power module if detachable or from the power source receptacle wall plug Power cord protection e Power cords should be routed so that they are not likely to be stepped on or pinched by items placed upon or against them Servicing Refer all servicing to qualified service personnel There are no user serviceable parts inside To prevent the risk of shock do not attempt to service this equipment yourself because opening or removing covers may expose you to dangerous voltage or other hazards Slots and openings If the equipment has slots or holes in the enclosure these are provided to prevent overheating of sensitive components inside These openings must never be blocked by other objects Lithium battery e There is a danger of explosion if battery is incorrectly replaced Replace it only with the same or equivalent type recommended by the manufacturer Dispose of used batteries according to the manufacturer s instructions Avertissement Alimentationse Ne faire fonctionner ce mat riel qu avec la source d alimentation indiqu e sur l appareil Ce mat riel doit tre utilis avec une alimentation principale comportant un fil de terre neutre Le troisi me contact de mise la terre constitue un dispositif de s curit n essayez pas de la contourner ni de la d sactiver D connexi
5. of component video 0 3 Vp p for C of S video Minimum maximum levels 0 3 V to 1 45 Vp p with no offset at unity gain EE ees 75 ohms Horizontal freguencn 15 kHz to 130 kHz Vertical frequency 30 Hz to 150 Hz e cide qs cto erence ene s lt 30 dB 5 MHz DC offset max allowable 100 mV Video output refer to the TP Receivers Family User s Manual part 68 547 02 Audio audio models Number sional ty pe icsseriscssesseasess 1 or 2 sets of analog proprietary signals Connectors TP T RAD ss crpcctsoarecintatinteee 1 2 pin direct insertion captive screw connector All other models 1 or 2 female RJ 45 Frequency response cesses 20 Hz to 20 kHz 0 05 dB THD Noise cccceeeeeseeceeeceeseeeeees 0 03 1 kHz 0 3 20 kHz at nominal level BIN E gt 63 dB at maximum output unweighted Eegenen lt 80 dB 1 kHz fully loaded Stereo channel separation gt 66 6 dB 1 kHz Ee gt 33 dB 20 Hz to 20 kHz Audio input audio models Number signal type TP T 15HD A TP T A 45 1 stereo unbalanced TP T 15HD AV E 2 stereo unbalanced Connectors TP T 15HD A TP T A 45 1 3 5 mm mini jack TP T 15HD AV serevesstensnseses 1 3 5 mm mini jack 2 female RCA ene 5k ohms unbalanced DC coupled Nominal level c cceseeseeeeeeees 10 dBV 316 mV TP T 15HD 45 and TP T A 45 Reference Information A 3 Reference Information cont d Maximum Ievel 5 5 dBu
6. unbalanced at 1 THD N Eegen gt 75 dB 20 Hz to 20 kHz NOTE 0 dBu 0 775 Vrms 0 dBV 1 Vrms 0 dBV x 2 dBu Audio output refer to the TP Receivers Family User s Manual part 68 547 02 General Recommended cable type Enhanced Skew Free A V UTP Cable or CAT 5 5E 6 shielded or unshielded Power TP T 15HD A TP T 15HD AV 15 VDC 0 8 A external or provided by the TP R receiver for up to 300 91 4 m TP T BNC DAG 15 VDC 0 8 A external TPT Ee IR 12 VDC 1 0 A external EE esson Shared with the TP T 15HD 45 transmitter NOTE The TP R 15HD A receiver does not provide power to any twisted pair transmitter Temperature humidity Storage 40 to 158 F 40 to 70 C 10 to 90 noncondensing Operating 32 to 122 F 0 to 50 C 10 to 90 noncondensing Scola ae ene ee eee Convection no vents Mounting Rack mount TP T 15HD A TP T 15HD AV TP T BNC TP T BNC DA4 Yes with the optional TP rack shelf mounting kit and an optional standard rack shelf kit Furniture mount TP T 15HD A TP T 15HD AV TP T BNC DA4 Yes with an optional under desk or through desk mounting kit TP T 15HD 45 TP T A 45 No but mountable in a 45 mm x 45 mm opening in common European wall boxes floor boxes or cable channel systems A 4 TP T 15HD 45 and TPT A 45 e Reference Information Eet Metal Enclosure dimensions TP T 15 HDA TP T 15 HD AV TP T BNC DA4 1 3 H x 6 8 W x 4 5 D lt 1U high l
7. 1024 x 768 1280 x 960 1280 x 1024 1360 x 765 1365 x 768 1366 x 768 1440 x 900 1400 x 1050 1600 x 1200 1920 x 1200 700 feet 700 feet 700 feet 500 feet 400 feet 300 feet 300 feet 250 feet 250 feet 250 feet 250 feet 250 feet 250 feet 200 feet 200 feet 800 feet 800 feet 800 feet 550 feet 450 feet 400 feet 350 feet 300 feet 300 feet 300 feet 300 feet 300 feet 300 feet 250 feet 250 feet TP T 15HD 45 and TP T A 45 e Introduction 1000 feet 1000 feet 1000 feet 1000 feet 800 feet 600 feet 450 feet 400 feet 400 feet 400 feet 400 feet 350 feet 350 feet 300 feet 300 feet 1050 feet 1050 feet 1050 feet 1050 feet 900 feet 700 feet 600 feet 500 feet 500 feet 500 feet 500 feet 450 feet 450 feet 400 feet 400 feet VTROO1 is not compatible with component composite or S video NOTE It is possible to exceed the recommended distances however image quality may be reduced Features 45 mm opening compatibility The TP T 15HD 45 and TP T A 45 are designed to fit into a 45 mm mounting frame that is popular throughout Europe The plate may be wall mounted or floor box mounted Extron TP product compatibility The TP T 15HD 45 and TP T A 45 are compatible with several Extron TP receivers and matrix switchers including the TP R 15HD A TP R BNC A TP R BNC AV TPX 88 TPX 88A and the VTR series RGBHV and RGBS only TP T 15HD 45 and TP T A 45 e Introduction 1 3
8. 16 Ichibancho 1001 East Ball Road Chiyoda ku Tokyo 102 0082 Anaheim CA 92805 Japan USA China Europe Africa and the Middle East Extron China Extron Europe 686 Ronghua Road Hanzeboulevard 10 Songjiang District 3825 PH Amersfoort Shanghai 201611 The Netherlands China Asia Middle East Extron Asia Extron Middle East 135 Joo Seng Road 04 01 Dubai Airport Free Zone PM Industrial Bldg F12 PO Box 293666 Singapore 368363 United Arab Emirates Dubai Singapore This Limited Warranty does not apply if the fault has been caused by misuse improper handling care electrical or mechanical abuse abnormal operating conditions or non Extron authorized modification to the product If it has been determined that the product is defective please call Extron and ask for an Applications Engineer at 714 491 1500 USA 31 33 453 4040 Europe 65 6383 4400 Asia or 81 3 3511 7655 Japan to receive an RA Return Authorization number This will begin the repair process as quickly as possible Units must be returned insured with shipping charges prepaid If not insured you assume the risk of loss or damage during shipment Returned units must include the serial number and a description of the problem as well as the name of the person to contact in case there are any questions Extron Electronics makes no further warranties either expressed or implied with respect to the product and its quality performance merchantability or fitness for any p
9. D 45 and TP T A 45 e Installation 2 3 Installation NOTE Strip approximately 0 43 inch 1 1 cm of insulation from each individual wire on one end of a TP cable 12345678 A CA LAA SN eu AA Le EE An CH RAA Wy QQ EEN ENEE KA EE DA 1 amp 2 7 amp 8 3 amp 6 4 amp 5 Twisted Wire Pairs Gi Power input captive screw connector Connect power input cables to the 2 pole female direct insertion captive screw connector 12 VDC C F PA MDS Power Input Captive Screw Direct Insertion Connector EZENN Remove power before wiring 4 Digital audio output captive screw connector Connect the digital audio output cables to the 2 pole female direct insertion captive screw connector Gi L AUDIO Deng AUDIO Digital Audio Output Captive Screw Direct Insertion Connector ZENNA Remove power before wiring 2 4 TP T 15HD 45 and TP T A 45 e Installation Front Panel Connectors and Indicators y eg COMPUTER re INPUT Extron TP T 15HD 45 TP TA45 Figure 2 2 Front panel views Power LED indicator The LED lights green whenever m is applied 10 5 15 pin HD video input connector Connect E Ss computer video input to this connector Female NOTE Input only sync signals no video signals on the sync pins 13 and 14 For component video use the R R Y and R return pins pins 1 and 6 G X and G return pins p
10. Extron Electronics INTERFACING SWITCHING AND CONTROL ot yro User s Manual TP T 15HD 45 and TP T A 45 Twisted Pair Video and Audio Transmitters 68 924 01 Rev D 12 09 Precautions Safety Instructions e English This symbol is intended to alert the user of important operating and maintenance servicing instructions in the literature provided with the equipment This symbol is intended to alert the user of the presence of uninsulated dangerous voltage within the product s enclosure that may present a risk of electric shock Caution Read Instructions Read and understand all safety and operating instructions before using the equipment Retain Instructions e The safety instructions should be kept for future reference Follow Warnings e Follow all warnings and instructions marked on the equipment or in the user information Avoid Attachments e Do not use tools or attachments that are not recommended by the equipment manufacturer because they may be hazardous Consignes de S curit Francais Ce symbole sert a avertir l utilisateur que la documentation fournie avec le mat riel contient des instructions importantes concernant l exploitation et la maintenance r paration Ce symbole sert a avertir l utilisateur de la pr sence dans le bo tier de l appareil de tensions dangereuses non isol es posant des risques d lectrocution Attention Lire les instructionse Prendre connaissance de toute
11. TP T 15HD 45 and TP T A 45 e Installation Captive screw digital audio input connector Connect the digital audio input cables from the TP T A 45 if installed to the 2 pole female direct insertion captive screw connector pad AUDIO C_F AUDIO Digital Audio Input Captive Screw Direct Insertion Connector EZENN Remove power before wiring NOTE The wire gauge should be 14 22 AWG and the maximum distance betwee the modules should not exceed 2a Teel Video and audio output 8 pin spring force connector Attach a UTP cable from a TP receiver to the 8 pin spring force connector Wire this connector according to the following pin assignment table Twisted Pair Pin Assignments TIA EIA T 568 A TIA EIA T 568 B Wire Color Wire Color red vertical sync white green white orange red vertical sync green orange digital audio white orange white green green blue blue green white blue white blue digital audio orange green blue horizontal sync white brown white brown blue horizontal sync brown brown NOTE T 568 A is recommended when using an Extron Skew Free cable CAUTION Do not connect the transmitter to a computer data or telecommunications network Using a small screwdriver and observing the correct wiring colors in the previous table insert the stripped wire ends see note below of the twisted pairs into the spring force connector as shown in the following diagram TP T 15H
12. alojamiento es para evitar el sobrecalientamiento de componentes internos sensibles Estas aberturas nunca se deben obstruir con otros objetos Bater a de litio e Existe riesgo de explosi n si esta bater a se coloca en la posici n incorrecta Cambiar esta bater a nicamente con el mismo tipo o su equivalente recomendado por el fabricante Desachar las baterias usadas siguiendo las instrucciones del fabricante EMM e AM S Bim e xi Deich EH S xT SETDAPAR RAAT DA NA He RA SRA SS AIRE ROE SPAR CER JE Se BEI dE HRE eee e REER e WAN MARTIN WERENT A N CARE ACH TT FELLA RAR dE Side FAHEY FLA eeng SABE BRIR HR eier mt E E IATA LIEN UENO RNIT HAAN iL ER OB SCAG HL POT DL E AE te MAE H DREES EE SE EEN RET Se A AE FB BAFL AEC AHL LAL Mtb CEKU RFR HP DRE BLS DOE BLP BUR TELA AREF EE Ze EY SHAUL GE 7 HERR AEWA THIEN TUE eye o HFE an rem CRNA K oi RREA El st n hp RRES H PATER TE DL at ADS EE HELI BEREH e PREZ in AA HECER EMERE MEE m geg PRAM A De Hh denk Sri MARMARA TH EXIF TEE EIER FCC Class A Notice This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 thi
13. articular use In no event will Extron Electronics be liable for direct indirect or consequential damages resulting from any defect in this product even if Extron Electronics has been advised of such damage Please note that laws vary from state to state and country to country and that some provisions of this warranty may not apply to you Extron USA West Extron USA East Extron Europe Extron Asia Extron Japan Extron China Extron Middle East Headquarters RK 800 633 9876 800 3987 6673 800 7339 8766 81 3 3511 7655 400 883 1568 971 4 2991800 800 633 9876 Inside USA Canada Only Inside Europe Only Inside Asia Only 81 3 3511 7656 FAX Inside China Only 971 4 2991880 FAX Inside USA Canada Only 1 919 863 1794 31 33 453 4040 65 6383 4400 86 21 3760 1568 1 714 491 1500 1 919 863 1797 FAX 31 33 453 4050 FAX 65 6383 4664 FAX 86 21 3760 1566 FAX 1 714 491 1517 FAX 2009 Extron Electronics All rights reserved
14. device to the output connector of the receiver Connect a computer to the 15 pin video input connector of the transmitter D Gi Gi Connect and power up all input and output devices then apply power to the TP T 15HD 45 power supply and test for the display and or audio outputs If a problem is encountered check all connections before proceeding further If the previous display and or audio test was successful power off and disconnect all equipment detach cables and install the TP T 15HD 45 and or TP T A 45 modules See Mounting in this chapter NOTE If the transmitter or receiver is to be wall mounted and the power supply will be inaccessible power must be applied to the power supply before final mounting Connect all device and power cables Power up all input and output devices apply power to the transmitter and receiver and test for the display the audio or both Compatibilty with other Extron products As a pair the TP T 15HD 45 and TP T A 45 are compatible with the following Extron receivers and matrix switchers e TPRI5HDA e TPRBNCA TP R BNC AV 2 6 TP T 15HD 45 and TP T A 45 e Installation e TPX 88A As a stand alone transmitter the TP T 15HD 45 is compatible with e VTROO1 VTROO1 AAP and VTR001 MAAP RGBHV RGBS only e TPX 88 Cable testing To ensure proper cable termination each transmission cable system that uses CAT 5e or CAT 6 cable should be tested Extron Skew Free cable do
15. er te die nicht ausdr cklich vom Hersteller empfohlen wurden da diese eine Gefahrenquelle darstellen k nnen Instrucciones de seguridad e Espa ol Este s mbolo se utiliza para advertir al usuario sobre instrucciones importantes de operaci n y mantenimiento o cambio de partes que se desean destacar en el contenido de la documentaci n suministrada con los equipos Este s mbolo se utiliza para advertir al usuario sobre la presencia de elementos con voltaje peligroso sin protecci n aislante que puedan encontrarse dentro de la caja o alojamiento del producto y que puedan representar riesgo de electrocuci n Precaucion Leer las instrucciones Leer y analizar todas las instrucciones de operaci n y seguridad antes de usar el equipo Conservar las instrucciones e Conservar las instrucciones de seguridad para futura consulta Obedecer las advertencias Todas las advertencias e instrucciones marcadas en el equipo o en la documentaci n del usuario deben ser obedecidas Evitar el uso de accesorios No usar herramientas o accesorios que no sean especificamente recomendados por el fabricante ya que podrian implicar riesgos Warning Power sources s This equipment should be operated only from the power source indicated on the product This equipment is intended to be used with a main power system with a grounded neutral conductor The third grounding pin is a safety feature do not attempt to bypass or disable it
16. er einen vergleichbaren Batterietyp der auch vom Hersteller empfohlen wird Entsorgen Sie verbrauchte Batterien bitte gem t den Herstelleranweisungen Advertencia Alimentaci n el ctrica e Este equipo debe conectarse nicamente a la fuente tipo de alimentaci n el ctrica indicada en el mismo La alimentaci n el ctrica de este equipo debe provenir de un sistema de distribuci n general con conductor neutro a tierra La tercera pata puesta a tierra es una medida de seguridad no puentearia ni eliminaria Desconexi n de alimentaci n el ctrica e Para desconectar con seguridad la acometida de alimentaci n el ctrica al equipo desenchufar todos los cables de alimentaci n en el panel trasero del equipo o desenchufar el m dulo de alimentaci n si fuera independiente o desenchufar el cable del receptaculo de la pared Protecci n del cables de alimentaci n Los cables de alimentaci n el ctrica se deben instalar en lugares donde no sean pisados ni apretados por objetos que se puedan apoyar sobre ellos Reparaciones mantenimiento e Solicitar siempre los servicios t cnicos de personal calificado En el interior no hay partes a las que el usuario deba acceder Para evitar riesgo de electrocuci6n no intentar personalmente la reparaci n mantenimiento de este equipo ya que al abrir o extraer las tapas puede quedar expuesto a voltajes peligrosos u otros riesgos Ranuras y aberturas e Si el equipo posee ranuras o orificios en su caja
17. es not need to be tested Testing the cable from the transmitter and receiver gives the most accurate indications of cable problems There are two varieties of cable runs simple runs in which a single cable is terminated only at the transmitter and receiver and complex runs which can include patch bays and multiple terminations and lengths of cable In either case the entire cabling system should be tested A complete test measures cable length and tests the wire map attenuation NEXT PSNEXT ELFEXT PSELFEXT return loss ACR and PSACR All of these tests are critical for digital data transfer While all of these tests are important indicators of the quality of the cable termination the most critical testing parameters for video transfer are wire map T 568 A or T 568 B termination and pair length measurements The largest concern is equalization of skew between cable pairs Cable systems of 300 feet or less should exhibit no transmission problems if they pass at least CAT 5e or preferably CAT 6 D5 channel certification testing The Microtest OMNI SCANNER 2 performs comprehensive certification testing to the proposed CAT 6 standards Other manufacturers also make testing equipment The tests include advanced diagnostics for troubleshooting the cause and location of many cable and termination problems For simple installation testing the Microtest MICRO SCANNER PRO tests wire map and cable length including individual cable pair leng
18. ins 2 and 7 and B B Y and B return pins pins 3 and 8 For S video use the R R return C chroma G and G return Y luma pins For composite video use the G pin and the associated return pin For additional genlocked video signals use the R B and associated return pins The TP T 15HD 45 and TP T A 45 are only compatible with the RGBHV and RGBS VTR series of receivers Gi 3 5 mm stereo mini jack input Connect unbalanced audio to this stereo jack Wire the A male plug as shown on the right e e A Sleeve NOTE Input only analog and line level audio signals on this connector TP T 15HD 45 and TP T A 45 e Installation 2 5 Installation cont d Cabling and Setup To install the TP T 15HD 45 and TP T A 45 models follow these steps Turn all of the equipment off and if applicable disconnect it from the power source Connect the TP T 15HD 45 and its receiver to either end of the UTP cable See Cable testing and Skew delay problems in this chapter NOTE For best results use Extron Skew Free cable available in bulk or in various preterminated lengths If necessary regular CAT 5 CAT be and CAT 6 cable may be used Connect the external power supply to the TP T 15HD 45 and TP T A 45 if installed See Rear Panel Connectors in this chapter If the TP T A 45 is being installed connect the TP T A 45 to the transmitter See Rear Panel Connectors in this chapter Connect an output display
19. lle betrieben werden Dieses Ger t wurde fiir eine Verwendung mit einer Hauptstromleitung mit einem geerdeten neutralen Leiter konzipiert Der dritte Kontakt ist f r einen Erdanschlu amp und stellt eine Sicherheitsfunktion dar Diese sollte nicht umgangen oder aufer Betrieb gesetzt werden Stromunterbrechung e Um das Ger t auf sichere Weise vom Netz zu trennen sollten Sie alle Netzkabel aus der R ckseite des Ger tes aus der externen Stomversorgung falls dies m glich ist oder aus der Wandsteckdose ziehen Schutz des Netzkabels e Netzkabel sollten stets so verlegt werden daf sie nicht im Weg liegen und niemand darauf treten kann oder Objekte darauf oder unmittelbar dagegengestellt werden k nnen Wartung e Alle Wartungsmafsnahmen sollten nur von qualifiziertem Servicepersonal durchgef hrt werden Die internen Komponenten des Ger tes sind wartungsfrei Zur Vermeidung eines elektrischen Schocks versuchen Sie in keinem Fall dieses Ger t selbst ffnen da beim Entfernen der Abdeckungen die Gefahr eines elektrischen Schlags und oder andere Gefahren bestehen Schlitze und ffnungen e Wenn das Ger t Schlitze oder L cher im Geh use aufweist dienen diese zur Vermeidung einer Uberhitzung der empfindlichen Teile im Inneren Diese Offnungen d rfen niemals von anderen Objekten blockiert werden Litium Batterie e Explosionsgefahr falls die Batterie nicht richtig ersetzt wird Ersetzen Sie verbrauchte Batterien nur durch den gleichen od
20. on de l alimentatione Pour mettre le mat riel hors tension sans danger d connectez tous les cordons d alimentation de l arri re de l appareil ou du module d alimentation de bureau s il est amovible ou encore de la prise secteur Protection du cordon d alimentation e Acheminer les cordons d alimentation de mani re A ce que personne ne risque de marcher dessus et a ce qu ils ne soient pas cras s ou pinc s par des objets R paration maintenance Faire ex cuter toutes les interventions de r paration maintenance par un technicien qualifi Aucun des l ments internes ne peut tre r par par l utilisateur Afin d viter tout danger d lectrocution l utilisateur ne doit pas essayer de proc der lui m me ces op rations car l ouverture ou le retrait des couvercles risquent de l exposer a de hautes tensions et autres dangers Fentes et orifices Si le bo tier de l appareil comporte des fentes ou des orifices ceux ci servent a emp cher les composants internes sensibles de surchauffer Ces ouvertures ne doivent jamais tre bloqu es par des objets Lithium Batterie e I a danger d explosion SU y a remplacment incorrect de la batterie Remplacer uniquement avec une batterie du meme type ou d un ype equivalent recommande par le constructeur Mettre au reut les batteries usagees conformement aux instructions du fabricant Vorsicht Stromquellen e Dieses Ger t sollte nur ber die auf dem Produkt angegebene Stromque
21. onnector 10 319 15 3 5 mm 5 pole captive screw connector 10 319 10 3 5 mm 10 pole captive screw connector 10 319 11 User s manual Accessories Accessories Part number 1U 3 5 inch deep rack shelf kit 60 190 20 1U 3 5 inch deep basic rack shelf 60 604 20 1U 6 inch deep universal rack shelf kit 60 190 10 1U 6 inch deep basic rack shelf 60 604 10 1U 9 5 inch deep universal rack shelf kit 60 190 01 1U 9 5 inch deep basic rack shelf 60 604 01 Mini under desk mounting bracket kit 70 212 01 Multi product projector mounting kit 70 374 01 1 4 rack width mini projector mounting 70 217 01 kit TP T 15HD 45 and TP T A 45 e Reference Information A 7 Reference Information A 8 TP T 15HD 45 and TPT A 45 e Reference Information Extron Warranty Extron Electronics warrants this product against defects in materials and workmanship for a period of three years from the date of purchase In the event of malfunction during the warranty period attributable directly to faulty workmanship and or materials Extron Electronics will at its option repair or replace said products or components to whatever extent it shall deem necessary to restore said product to proper operating condition provided that it is returned within the warranty period with proof of purchase and description of malfunction to USA Canada South America Japan and Central America Extron Japan Extron USA Kyodo Building
22. s device must accept any interference received including interference that may cause undesired operation The Class A limits are designed to provide reasonable protection against harmful interference when the equipment is operated in acommercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense VIe This unit was tested with shielded cables on the peripheral devices Shielded cables must be used with the unit to ensure compliance with FCC emissions limits Table of Contents Chapter One e Introduction 0 000 1 ahi ges ek d V Tu E 1 2 Feallsair e ai 1 3 Chapter Two Installation eee 1 Rear Panel Connectors 0 0 0 0 ccc ce ccsceeeceeeceeeseeeseesseneseeneeess 2 2 Front Panel Connectors and Indicators 00010a0a1aaa 2 5 Cabling and Setup E 2 6 Compatibilty with other Extron products c ccccee 2 6 Cable testing cccccecceececeeeeeeeeeeeeeeeeeeeeeeeeeesaeeaaeeeeeeeeeeeeees 2 7 Skew delay problems nnnnsnnnneneeennnnnnnenenrnr nn nnnneeneenrr nenene 2 7 MOUNN EE 2 8 Appendix A e Reference Information A 1 Specifications
23. s les consignes de s curit et d exploitation avant d utiliser le mat riel Conserver les instructionse Ranger les consignes de s curit afin de pouvoir les consulter a l avenir Respecter les avertissements e Observer tous les avertissements et consignes marqu s sur le mat riel ou pr sent s dans la documentation utilisateur Eviter les pi ces de fixation e Ne pas utiliser de pi ces de fixation ni d outils non recommand s par le fabricant du mat riel car cela risquerait de poser certains dangers Sicherheitsanleitungen e Deutsch Dieses Symbol soll dem Benutzer in der im Lieferumfang enthaltenen Dokumentation besonders wichtige Hinweise zur Bedienung und Wartung Instandhaltung geben Dieses Symbol soll den Benutzer daraufaufmerksam machen da im Inneren des Geh uses dieses Produktes gef hrliche Spannungen die nichtisoliert sind und die einen elektrischen Schock verursachen k nnen herrschen Achtung Lesen der Anleitungen e Bevor Sie das Ger t zum ersten Mal verwenden sollten Sie alle Sicherheits und Bedienungsanleitungen genau durchlesen und verstehen Aufbewahren der Anleitungen e Die Hinweise zur elektrischen Sicherheit des Produktes sollten Sie aufbewahren damit Sie im Bedarfsfall darauf zur ckgreifen k nnen Befolgen der Warnhinweise Befolgen Sie alle Warnhinweise und Anleitungen auf dem Ger t oder in der Benutzerdokumentation Keine Zusatzger te e Verwenden Sie keine Werkzeuge oder Zusatzg
24. t half rack width 3 3 cm H x 17 3 cm W x 11 4 cm D Depth excludes connectors TP T 15HD 45 TP T A 45 Eege 1 8 H x 1 8 W x 0 8 D 4 5 cm H x 4 5 cm W x 2 0 cm D DEVICE ssceunsicecesesreasedaces 1 1 H x 1 6 W x 1 2 D 2 9 cm H x 4 1 cm W x 3 0 cm D Depth excludes front and rear panel connectors and controls Product weight TP T 15HD A TP T 15HD AV 0 8 Ibs 0 4 kg TP T BNC DAG eee 0 9 Ibs 0 4 kg TP T 15HD 45 TP T A 45 0 3 lbs 0 1 kg Shipping weight eegene eege 3 Ibs 2 kg Keier ee ISTA 1A in carton International Safe Transit Association Regulatory compliance all models except TP T 15HD 45 and TP T A 45 SE CE c UL UL LE REEL CE C tick FCC Class A ICES VCCI MIDE E 30 000 hours Eeer 3 years parts and labor NOTE All nominal levels are at 10 eu Specifications are subject to change without notice TP T 15HD 45 and TP T A 45 e Reference Information A 5 Reference Information A 6 TP T 15HD 45 and TPT A 45 e Reference Information Included Parts These items are included in each order for an IR 102 Remote Kit part 70 224 01 Included parts Replacement part number IR 102 Rx Remote Receiver IR 102 Handheld Remote Control 70 224 10 12 VDC 1 A external power supply kit 70 055 01 IR sensor on a 6 foot cable RS 232 male to female cable 6 feet 1 8 m 26 433 03 IEC power cord Tweeker small screwdriver Hook and loop fasteners 3 5 mm 2 pole captive screw c
25. th Skew delay problems CAT 5 TP cable can lead to registration errors between the red green and blue video signals Pair skew can be measured with test equipment or identified by viewing a crosshatch test pattern with a critical eye to determine if either the red green or blue video image leads appears to the left of the other two video images These images can be minimized or eliminated by one of the following methods TP T 15HD 45 and TP T A 45 Installation 2 7 Installation cont d e Switch to Extron Skew Free cable e Add a skew compensation cable equal to the length of pair skew to the receiver s output e Install an SEQ 100 15HD Skew Equalizer on the video output of the receiver and adjust the skew for the leading video image Mounting The TP T 15HD 45 and TP T A 45 are designed to fit into a wall mountable or floor box mountable 45 mm mounting frame Se COMPUTER AUDIO oe INPUT Extron Extron INPUT The following application diagram illustrates one example of installing these devices Projector Mounting Bracket Extron e TP R 15HD A Twisted Pair Receiver e Mounting Bolt CAT 5 6 or Extron Skew Free UTP Cable Up to 500 feet Extron TPT A 45 TPT 15HD 45 Twisted Pair Transmitters 2 8 TP T 15HD 45 and TP T A 45 e Installation 3 TPT 45HD 45 and TP T A 45 Appendix A Reference Information Specifications Parts Lists Reference Information
Download Pdf Manuals
Related Search
Related Contents
取扱説明書 Patton electronic Serial G.SHDSL Bridge/Router 3087 User's Manual Institut "Jožef Stefan", Ljubljana, Slovenija Troubleshooting Tips User Manual - v Robocall User Guide Bandridge BBM39300W20 USB cable Copyright © All rights reserved.
Failed to retrieve file