Home

ExtremeXOS 12.1 - Release Notes

image

Contents

1. Summit X450a Series Summit X450a 48t summitX 12 1 4 2 patch1 8 xos 11 5 1 4 1 0 2 2 Summit X450a 48tDC summitX 12 1 4 2 patch1 8 xos 11 6 1 9 1 0 2 2 Summit X450a 24t summitX 12 1 4 2 patch1 8 xos ROTTA 1 0 2 2 Summit X450a 24tDC summitX 12 1 4 2 patch1 8 xos 11 5 1 4 1022 Summit X450a 24xDC summitX 12 1 4 2 patch1 8 xos 11 6 1 9 1 0 2 2 Summit X450a 24x summitX 12 1 4 2 patch1 8 xos 11 6 1 9 1 0 2 2 Summit X450e Series Summit X450e 24p summitX 12 1 4 2 patch1 8 xos Tal Sy gal 10 22 Summit X450e 48p summitX 12 1 4 2 patch1 8 xos 11 6 1 9 1 0 2 2 Summit X450 Series Summit X450 24x summitX 12 1 4 2 patch1 8 xos 11 2 2 4 1 0 0 9 Summit X450 24t summitX 12 1 4 2 patch1 8 xos 11 2 2 4 1 0 0 9 Option Cards XGM 2xn summitX 12 1 4 2 patch1 8 xos N A N A XGM2 2xn summitX 12 1 4 2 patch1 8 xos 11 5 1 4 XGM2 2xf summitX 12 1 4 2 patch1 8 xos 11 5 1 4 ExtremeXOS 12 1 4 Installation and Release Notes e dd note Upgrading the BootROM on a Summit X450 switch is not automatic when you upgrade the software You must be running the minimum required BootROM version Use the download bootrom command to download a BootROM image SFP Mini GBIC Support SFPs supported on the BlackDiamond 8810 and BlackDiamond 8806 switches with ExtremeXOS 12 1 and the minimum ExtremeXOS version required include Table 8 BlackDiamond 8800 Series of Switches SFP Support SFP ExtremeXOS Required 1O00B
2. Metric Product Limit ESRP VLANs maximum number of ESRP BlackDiamond 8800 series 1 000 MLN BlackDiamond 10808 3 000 BlackDiamond 12800 series 3 000 Summit series 1 000 ESRP maximum ping tracks maximum number All platforms 8 of IP route tracks per VLAN ESRP IP route tracks maximum IP route All platforms 8 tracks per VLAN ESRP VLAN tracks maximum number of VLAN All platforms ili tracks per VLAN Forwarding rate maximum L2 L3 software BlackDiamond 8800 series 10 000 pps fonveneling teta BlackDiamond 12800 series 16 000 Summit X250e 10 000 pps Summit X450 10 000 pps FDB blackhole entries maximum number of BlackDiamond 8800 original series 16 000 unies bleckhole FDB euliles BlackDiamond 8800 a series 16 000 BlackDiamond 8800 e series 8 000 Summit X450 original 16 000 Summit X450a 16 000 Summit X450e 8 000 FDB blackhole entries maximum number of BlackDiamond 8800 original series 256 multicast blackhole FDB entries Rlaer Demon E200 esis 1 024 BlackDiamond 8800 e series 1 024 Summit X450 original 256 Summit X450a 1 024 Summit X450e 1 024 FDB maximum L2 L3 entries maximum number BlackDiamond 10808 224 000 of MAC addresses IP host routes BlackDiamond 2800 series 49 000 BlackDiamond 12800 R series 224 000 FDB maximum L2 entries maximum number of BlackDiamond 8800 original 16 384 UNOS ESS BlackDiamond 8800 c series 32 768 BlackDiamond 8800 a series 16 384 BlackDiamond 8800
3. ExtremeXOS 12 1 4 Installation and Release Notes Metric Product Limit VLANs Layer 3 maximum number of Layer 3 All platforms 512 VLANs VLANs maximum active port based number of All platforms 4 094 simultaneously active port based VLANs VLANs maximum active protocol sensitive All platforms 15 filters number of simultaneously active protocol filters in the switch VLAN translation maximum number of BlackDiamond 8800 a c and e series translation VLANs Assumes a minimum of one port per translation and member VLAN withe ienimodules sir 8 eects 383 BlackDiamond 10808 1 400 BlackDiamond 12800 series 1 400 Summit X450a and X450e 24 port with two port option card 25 without option card 23 Summit X450a and X450e 48 port with two port option card 49 without option card 47 VLAN translation maximum number of All platforms 512 translation VLAN pairs with an IP address on the translation VLAN VLAN translation maximum number of All platforms 2 046 translation VLAN pairs in an L2 only environment vMAN maximum ACL rules for VMAN maximum BlackDiamond 10808 4 000 number of ACL rules for vMAN BlackDiamond 12800 series 4 000 VPLS VCCV pseudo wire Virtual Circuit BlackDiamond 10808 16 Connectivity Verification VPNs maximum number of VCCV enabled VPLS VPNs BleckPiememi 12800 Rears ae VPLS MAC addresses in an H VPLS network BlackDiamond 10808 60 000 maximum
4. Support for Overlapping Aggregate Routes BGP now supports overlapping routes The following command description has been updated for this feature e configure bgp add aggregate address on page 26 ExtremeXOS 12 1 4 Installation and Release Notes configure bgp add ageregate address configure bgp add aggregate address address family ipv4 unicast ipv4 multicast lt ipaddress gt as match as set summary only advertise policy lt policy gt attribute policy lt policy gt Description Configures a BGP aggregate route Syntax Description address family The address family BGP supports two address families IPv4 unicast and IPv4 multicast ipaddress Specifies an IP network address and mask length as match Generates autonomous system sequence path information order of AS numbers in AS_PATH is preserved as set Generates autonomous system set path information order of AS numbers in AS_PATH is not preserved summary only Specifies to send only aggregated routes to the neighbors advertise policy Specifies the policy used to select routes for this aggregated route attribute policy Specifies the policy used to set the attributes of the aggregated route Default If no address family is specified IPv4 unicast is the default Usage Guidelines Route aggregation is the process of combining the characteristics of several routes so that they are advertised as a single route Aggregation reduces the amount of i
5. 2 Run the uninstall image bd10k 12 1 4 ssh xmod lt partition gt primary or secondary command This uninstalls SSH from your switch 3 Restart the thttpd process using the start process thttpd command Downgrading Switches Following are the instructions for downgrading your ExtremeXOS version 12 1 4 installation to a previous version It is assumed that you saved your configuration using the 11 4 1 image and that the 11 4 1 image is currently installed on the switch on the non booted partition Oo dd note Do not downgrade a BlackDiamond 8810 switch to an image earlier than 11 1 1 or a Summit X450 switch to an image earlier than 11 2 1 Do not downgrade a BlackDiamond 8806 switch to an image earlier than 11 3 1 3 Do not downgrade a Summit X450a or X450e switch to an ExtremeXOS image earlier than 11 5 1 To downgrade to the existing ExtremeXOS version 11 4 1 image on your system you will be following these steps 1 Determine your selected and booted image partitions Run the show switch command to determine your current selected and booted image partitions The selected image partition indicates which image will be used at the next reboot The booted image partition indicates which image was used at the last reboot Output from this command includes the version of the selected and booted images and if they are in the primary or the secondary partition In this example the selected and booted images are in the secondary parti
6. SummitStack PD4 441118181 PD4 453897651 Process AAA dies if a Vendor Specific Attribute VSA with a length greater than 130 bytes is included in a RADIUS packet Clients connected to a front panel port of a backup slot in a SummitStack cannot in some case communicate ARP ping with the switch This issue occurs only when load sharing is configured on ExtremeXOS switches using the ports from backup slots ExtremeXOS 12 1 4 Installation and Release Notes Table 55 Platform Specific and Feature PDs Continued CLI PD4 428888970 PD4 444518321 ELRP PD4 454742244 IGMP PD4 409050568 Multicast PD4 461646362 Network Login PD4 461738214 PD4 457325458 PD4 461738253 SNMP PD4 457325663 Logging out of a CLI session established using SSH or Telnet may result in a smbuf_xfer terminal signal error followed by a switch reboot When running the Extreme Loop Recovery Protocol ELRP between an ExtremeWare e series switch and an ExtremeXOS switch the ExtremeWare switch reports a checksum error When adding a static Internet Group Management Protocol IGMP group to a port not belonging to the assigned VLAN the switch silently drops the configuration without displaying an error or warning message With Multicast VLAN Registration MVR enabled on a switch adding or deleting a port from a non MVR VLAN results in the multicast entries being flushed or refreshed This is seen with Internet Group Management
7. Table 30 lists the CLI commands not supported on the Summit X150 and X350 series switches Table 30 Summit X150 and X350 Unsupported Commands Command Description configure Configure running system information ipforwarding Configure IP forwarding behavior ipmcforwarding Configure IP multicast forwarding parameters ipmroute IP multicast routing module irdp ICMP Router Discovery Protocol stacking Settings for stacking vlan vlan_name router discovery IPv6 router discovery vlan vlan_name udp profile UDP forwarding profile disable Disable running system setting esrp ESRP Extreme Standby Router Protocol Domain ipforwarding IP forwarding ipmcforwarding IP multicast forwarding help irdp ICMP Router Discovery Protocol router discovery IPv6 router discovery stacking Stacking enable Enable running system setting esrp lt esrp domain gt ESRP Extreme Standby Router Protocol Domain ipforwarding IP forwarding ipmcforwarding IP multicast forwarding help irdp ICMP Router Discovery Protocol router discovery IPv6 router discovery stacking Stacking reboot Reboot system node address Reboot a node in the stack stack topology Reboot stack topology show Show running system information router discovery IPv6 router discovery stacking Stacking information udp profile UDP forwa
8. as path 65001 permit ExtremeXOS 12 1 4 Installation and Release Notes enable bgp neighbor 10 203 134 5 originate default policy def_originate With this configuration a default route is originated and sent to neighbor 10 203 134 5 only if there is a BGP route in the local RIB which matches the statement nlri 192 168 3 0 24 If a matching route exists the default route is sent to neighbor 10 203 134 5 with the 65001 as path prepended If this is an EBGP neighbor then the local AS Number is prepended after 65001 If the route for the match statement nlri 192 168 3 0 24 goes away and there is no other matching route in the BGP RIB the default route origination feature becomes inactive and BGP withdraws the 0 0 0 0 0 default route from neighbor 10 203 134 5 When a matching route becomes available again in the local BGP RIB the default route origination feature becomes active again and the default route 0 0 0 0 0 is advertised to neighbor 10 203 134 5 Commands for Default Route Origination and Advertisement The following commands have been added or modified to support this feature disable bgp neighbor originate default on page 13 disable bgp peer group originate default on page 14 enable bgp neighbor originate default on page 15 enable bgp peer group originate default on page 17 show bgp neighbor lt remoteaddr gt show bgp neighbor detail ExtremeXOS 12 1 4 Installation and Release Notes disable bgp neighbor orig
9. ExtremeXOS 12 1 4 Installation and Release Notes Resolved Issues in ExtremeXOS 12 1 4 patch1 3 The following issues were resolved in ExtremeXOS 12 1 4 patch1 3 The numbers shown in column one of the following table are for internal reference and can be ignored ExtremeXOS 12 1 includes all fixes up to and including ExtremeXOS 11 1 4 4 ExtremeXOS 11 2 3 3 ExtremeXOS 11 3 4 5 ExtremeXOS 11 4 4 7 ExtremeXOS 11 5 2 10 ExtremeXOS 11 6 5 3 patch1 5 and ExtremeXOS 12 0 5 For information on those fixes see the release notes for the specific release Table 40 Platform Specific and Feature PDs PD Number Description General PD4 931823732 A loop occurs after disabling learning on a protected VLAN on an EAPS master Workaround To stop the loop disable and enable the EAPS primary port PD4 1099203316 Egress vMAN ACLs are not getting matched even though the traffic matching the ACL match condition is egressing the switch port BlackDiamond 8800 Series Switch PD4 983957922 After running an MSM failover the backup MSM shows an asterisk in the command prompt after rebooting the switch To clear this save the configuration RT030101_TEST_LAB 2 gt RT030101_TEST_LAB 2 gt show slot Summit Family Switches PD4 1155294979 On Summit X450 switches 1 Gigabit links take more time to detect a link down than PD4 460349822 100 Mbps links DHCP PD4 1124676271 DHCP OFFER and DHCP ACK packets are duplicated in a VLAN aggr
10. Series components supported with ExtremeXOS 12 1 and the minimum BootROM version required by the chassis to support each component include Table 4 BlackDiamond 12800 Series Switches Component Support BlackDiamond 12802 12804 Components ExtremeXOS Filenames ExtremeXOS Required BootROM Version MSM 5R BlackDiamond 12804 bd12k 12 1 4 2 patch1 8 xos 11 4 1 4 1 0 0 2 MSM 5R BlackDiamond 12802 bd12K 12 1 4 2 patch1 8 xos 12 0 1 11 1 0 0 2 GM 20XTR N A 11 4 1 4 N A XM 38R N A eA N A XM 2HR N A RRA N A MSM 5 BlackDiamond 12804 bd12k 12 1 4 2 patch1 8 xos 11 4 1 4 1 0 0 2 MSM 5 BlackDiamond 12802 bd12k 12 1 4 2 patch1 8 xos 12 0 1 11 1 0 0 2 MSM 6R bd12k 12 1 4 2 patch1 8 xos 12 0 2 25 1 0 1 8 GM 20XT N A 11 4 1 4 N A GM 20T N A FANIT N A PSU Controller N A 11 4 1 4 Pulls 700 1200 W AC PSU Model N A 11 4 1 4 N A 60020 PS 2336 1200 W DC PSU Model N A MATIA N A 60021 PS 2350 Summit X150 and X350 Component Support Summit X150 and X350 series components supported with ExtremeXOS 12 1 and the minimum BootROM version required by the chassis to support each component include Table 5 Summit X150 and X350 Component Support Minimum Summit X150 and X350 ExtremeX0S Minimum BootROM Components ExtremeXOS Filenames Required Version Summit X150 24t summitX 12 1 4 2 patch1 8 xos 12 0 2 25 Summit X150 48t summitX 12 1 4 2 patch1 8 xos 12 0 2 25 ORS Sum
11. Traffic switching performance drops by 50 to 90 when an MSM failover occurs between SVLANs and BVLANs PD3 180718721 BlackDiamond 88 PD3 151784861 When booting a dual MSM system the following error message may be displayed in the log for MSM A and MSM B This error message only applies to MSM B On MSM A BD 12804 3 show log severity error 11 07 2007 20 54 24 34 lt Erro DM Error gt MSM B Other MSM is 9 On MSM B BD 12804 1 gt show log severity error 11 07 2007 20 54 24 34 lt Erro DM Error gt MSM B Other MSM is 9 00 Series Switch 10G4Ca modules on BlackDiamond 8800 platforms may require custom pre emphasis settings on an interface by interface basis as some vendor cables and end devices require custom settings to operate without CRC errors ExtremeXOS 12 1 4 Installation and Release Notes Table 58 Platform Specific and Feature PDs Continued PD Number Description BlackDiamond 10808 Switch PD3 36734601 PD3 37075321 The Opnext ZR XENPAK module is displaying as an SR module on the BlackDiamond 10808 switch The Intel ER and Intel LR XENPAK modules are displaying as SR modules or unsupported on the BlackDiamond 10808 switch BlackDiamond 12800 Series Switches PD3 180903136 PD3 205448322 BlackDiamond 12800 series switches are not compatible with ExtremeXOS versions 11 6 or earlier It is recommended that these switches be loaded with ExtremeXOS 12 0 or later PD3 1
12. maximum number of CFM up end points All platforms 32 CFM maximum number of CFM down end All platforms 22 points CFM maximum number of CFM remote end All platforms 64 points CFM maximum number of dotlag ports All platforms 128 Dynamic ACLs maximum number of ACLs BlackDiamond 8800 with c series MSM processed per second and I O modules 8 Note Limits are load dependent BlackDiamond 12800 series 12 Summit X450a with 50 DACLs 10 with 500 DACLs 5 EAPS domains maximum number of EAPS BlackDiamond 8800 series 64 domains BlackDiamond 10808 128 Note An EAPS ring that is being spatially BicekWiamendclosetlecrice 128 reused cannot have more than four configured EAPS domains Summit series 32 EAPSv1 protected VLANs maximum number of BlackDiamond 8800 series 2 000 Dee Ne BlackDiamond 10808 4 000 BlackDiamond 12800 series 4 000 Summit series 1 000 EAPSv2 protected VLANs maximum number of BlackDiamond 8800 series 1 000 protected BAN BlackDiamond 10808 4 000 BlackDiamond 12800 series 4 000 Summit series 500 ELSM vlan ports maximum number of VLAN BlackDiamond 8800 series 5 000 ports BlackDiamond 10808 5 000 BlackDiamond 12800 series 5 000 ESRP groups maximum number of ESRP All platforms 7 groups ESRP domains maximum number of ESRP BlackDiamond 8800 series 64 domains BlackDiamond 10808 128 BlackDiamond 12800 series 64 Summit series 64 ExtremeXOS 12 1 4 Installation and Release Notes
13. Enabling IP route compression may cause temporary slow path forwarding for some of the L3 traffic PD3 192821161 Maximum Number of Supported IPv4 and IPv6 Interfaces For Summit X450 a series and e series switches and the BlackDiamond 8800 series of switches the maximum number of supported IP interfaces is 512 IPv4 and IPv6 combined If there are more IP interfaces configured the following log message is displayed 12 11 2007 06 06 14 73 lt Info HAL VLAN Info gt Maximum of IP interfaces 512 already configured Could not add IP address 0x0A010101 mask OxFFFFFFOO ExtremeXOS 12 1 4 Installation and Release Notes Table 32 Platform Specific and Feature PDs Continued PD Number PD3 201570011 Description Relay Agent IP Address Should be Configured as the Trusted Server When dhcp relay is configured in a DHCP snooping environment the relay agent IP address should be configured as the trusted server If the relay agent IP address is not configured as the trusted server DHCP responses are blocked PD3 190574171 Ports May Stay in Active State Even After the Cable is Disconnected Ports on Summit X450a and X450e series switches may stay in an active state even after the cable is disconnected with certain QoS configurations PD3 132775269 Telnet Sessions Between Two Switches Causing Mount Remount Problem Telnet sessions between two switches using two windows causes one session to hang if both sessi
14. Internal Tag 1 MAC uter VR Default STP cfg s0 disable Tag none Mode 802 1D Protocol Name Default Protocol ANY Trunking Load sharing is not enabled EDP Enabled ELSM Disabled Learning Enabled Unicast Flooding Enabled Multicast Flooding Enabled Broadcast Flooding Enabled Jumbo Disabled High Priority COS 7 Packet Length Adjustment 0 bytes QoS Profile None configured Aggregate Queue QPO MinBw 0 MaxBw Queue QP1 MinBw 0 MaxBw QP2 MinBw 0 MaxBw QP3 MinBw 0 MaxBw QP4 MinBw 0 MaxBw QP5 MinBw 0 MaxBw QP6 MinBw 0 MaxBw QP7 MinBw 0 MaxBw QP8 MinBw 0 MaxBw Ingress Rate Shaping Unsupported Ingress IPTOS Examination Disabled Egress IPTOS Replacement Disabled Egress 802 1p Replacement Disabled ExtremeXOS 12 1 4 Installation and Release Notes limit No limit Virtual ro State FORWARDING Match all protocols 100 Pri 8 100 Pri 1 100 Pri 2 100 Pri 3 100 Pri 4 100 Pri 5 100 Pri 6 100 Pri 7 100 Pri 8 NetLogin Disabled NetLogin port mode Port based VLANs Smart redundancy Enabled Software redundant port Disabled Preferred medium Fiber dd NOTE On the GM 20XT and GM 20XTR modules for the BlackDiamond 12800 series switch and 12800 R series switches you can use each port as either copper or fiber preferred medium displays which medium the specified port is using BlackDi
15. elrp ELRP Extreme Loop Recovery Protocol update Read epmrc configuration file save Save system configuration configuration System configuration primary Primary configuration file secondary Secondary configuration file show Show running system information access list Access list accounts Show accounts banner System login banner bootprelay Show the BOOTP relay information checkpoint data configuration Checkpoint data System configuration cpu monitoring CPU utilization statistics debug Debug information dhcp client Show information related to dhcp clients dhcp server Show information related to the dhcp server diagnostics Show diagnostic test results diffserv Diffserv dns client Show configuration dos protect Automatic denial of service protection dotlp Dot1p dotlq IEEE 802 1Q eaps EAPS Ethernet Automatic Protection Switching edp EDP information elrp ELRP Extreme Loop Recovery Protocol elsm ELSM Extreme Link Status Monitoring esrp ESR Extreme Standby Router Protocol failsafe account Show the failsafe account information fans Fan information fdb FDB forwarding Show settings for hardware forwarding heartbeat Monitor process health igmp IGMP Protocol inline power Inline Power ip security IP Security iparp IP ARP command ipconfig IP configuration ipmroute IP multicast routing mo
16. respond log message PD3 203517161 BlackDiamond 8800 Series Switch PD4 832478607 BlackDiamond 10808 Switch PD3 175604157 BlackDiamond 12800 Series Switches PD4 580590984 In a network where a BlackDiamond 8800 or a Summit X450 switch is forwarding packets occasional packet drop is observed on certain egress ports On BlackDiamond 8800 series switches when a port belongs to two different VRRP instances with the same VRID and one of the instances is a master VRID and the other a standby VRID broadcast packets belonging to the standby VRRP VLAN generated by the master VRRP in that VLAN are not forwarded A BlackDiamond 10808 switch with a dual speed copper fiber SFP shows a link as active even though a cable is not connected Meters cannot be disassociated from HQoS queues that are in use HQoS queues must first be removed before associated meters can be deleted PD3 206766987 Hitless upgrade is not supported for network login when upgrading from a previous version of ExtremeXOS software to ExtremeXOS 12 1 If you attempt to perform a hitless upgrade all existing clients must be reauthenticated after a failover Error messages such as genesisNetLoginHandleGet Port 0x08 NOT found may be shown on the console and the system log If a hitless upgrade is required it is recommended that you globally disable network login and re enable it when the upgrade is complete PD3 131941899 Summit F
17. 11 5 2 10 ExtremeXOS 11 6 5 3 patch1 5 and ExtremeXOS 12 0 5 For information on those fixes see the release notes for the specific release Table 38 Platform Specific and Feature PDs PD Number Description General PD4 1232462178 ExtremeXOS software is unable to upgrade an ExtremeXOS software license to any switch PD4 1221696686 that has a serial number beginning with 0953x xxxx using the enable license file lt license file xlic gt command EAPS PD3 175211031 The ExtremeXOS CLI does not prevent EAPS health check PDUs from looping using the permit all keywords when installing ACLs Resolved Issues in ExtremeXOS 12 1 4 patch1 4 The following issues were resolved in ExtremeXOS 12 1 4 patch1 4 The numbers shown in column one of the following table are for internal reference and can be ignored ExtremeXOS 12 1 includes all fixes up to and including ExtremeXOS 11 1 4 4 ExtremeXOS 11 2 3 3 ExtremeXOS 11 3 4 5 ExtremeXOS 11 4 4 7 ExtremeXOS 11 5 2 10 ExtremeXOS 11 6 5 3 patch1 5 and ExtremeXOS 12 0 5 For information on those fixes see the release notes for the specific release Table 39 Platform Specific and Feature PDs PD Number Description General PD4 1171055143 A triggered IGMP query with the wrong 802 1Q tag is sent on a vMAN enabled port PD4 1156762929 SNMP PD4 1155806081 When a switch receives UDP packets with a source port of 3503 memory depletion PD4 935076380 occurs and the switch may reboot
18. 16 e series modules per port groups 1 12 25 36 and 13 24 37 48 8 Summit X150 and X350 series 8 Summit X250e per port groups 1 24 and 25 48 8 Summit X450a per port groups 1 24 and 25 48 16 Summit X450e per port groups 1 25 8 AAA local maximum number of admin and All platforms 16 local user accounts BGP aggregates maximum number of BGP All platforms with Core license or above 256 aggregates BGP networks maximum number of BGP All platforms with Core license or above 1 024 networks ExtremeXOS 12 1 4 Installation and Release Notes Metric Product Limit BGP peers maximum number of BGP peers BlackDiamond 8800 series 256 BlackDiamond 10808 MSM 1XL 512 MSM 1 256 BlackDiamond 12800 series MSM 5 256 MSM 5R 256 MSM 6R 512 Summit X450 128 Summit X450a 128 With default keepalive and hold timers BGP peer groups maximum number of BGP All platforms with Core license or above 64 peer groups BGP policy entries maximum number of BGP All platforms with Core license or above 256 policy entries per route policy BGP policy statements maximum number of All platforms with Core license or above 1 024 BGP policy statements per route policy BGP unicast address family routes maximum BlackDiamond 8800 series 25 000 number of unicast address family routes LPM entries is limited to support TCAM entries on a BlackDiamond 10808 BlackDiamond 10808 MSM 1XL 1 000 000 MSM 1 400 000
19. 31 summarizes tested metrics for a variety of features as measured in a per system basis unless otherwise noted These limits may change but represent the current status The contents of this table supersede any values mentioned in the ExtremeXOS Concepts Guide dd NOTE The scaling and performance information shown in Table 31 is provided for the purpose of assisting with network design It is recommended that network architects and administrators design and manage networks with an appropriate level of network scaling head room The scaling and performance figures provided have been verified using specific network topologies using limited switch configurations There is no guarantee that the scaling and performance figures shown are applicable to all network topologies and switch configurations and are provided as a realistic estimation only If you experience scaling and performance characteristics that you feel are sufficiently below what has been documented contact Extreme Networks technical support for additional assistance Oo dd note The route limits shown in Table 31 for IPv4 and IPv6 routing protocols are software limits only The actual hardware limits may be lower than the software limits based on platform The hardware limits for specific platforms are specified as IPv4 IPv6 routes LPM entries in hardware in the following table oO dd NOTE On a BlackDiamond 8800 or a Summit X450 or X250e switch it is not advised to h
20. 448 IGMPv1 v2 SSM map entries maximum number All platforms 500 of IGMPv1 v2 SSM mapping entries IGMPv1 v2 SSM MAP entries maximum number All platforms 50 of sources per group in IGMPv1 v2 SSM Mapping entries IGMPv2 subscriber maximum number of BlackDiamond 8800 series 1 000 FMI SPSL Ca Ta te BlackDiamond 8800 c series 2 000 BlackDiamond 10808 5 000 BlackDiamond 12800 series 5 000 Summit series 1 000 IGMPv2 subscriber maximum number of BlackDiamond 8800 series 10 000 PMU subeciioais per switch BlackDiamond 8800 c series 20 000 BlackDiamond 10808 30 000 BlackDiamond 12800 series 30 000 Summit series 10 000 IGMPv3 maximum source per group maximum All platforms 250 number of source addresses per group ExtremeXOS 12 1 4 Installation and Release Notes Metric Product Limit IGMPv3 subscriber maximum number of BlackDiamond 8800 series 1 000 IGMPv3 subscribers per port BlackDiamond 8800 c series 2 000 BlackDiamond 10808 5 000 BlackDiamond 12800 series 5 000 Summit series 1 000 IGMPv3 subscriber maximum number of BlackDiamond 8800 series 10 000 IGMPv3 subscribers per switch BlackDiamond 8800 c series 20 000 BlackDiamond 10808 30 000 BlackDiamond 12800 series 30 000 Summit series 10 000 IP ARP entries in software maximum number of All platforms 20 480 IP ARP entries in software IPv4 ARP entries in hardware with minimum LPM BlackDiamond 8800 c series 8 000 E recommended numberof lackDiamo
21. ACL PD4 666817942 PD4 623943603 A non maskable interrupt occurs while displaying system failure information because of a deadlock in printk 00 Series Switch When mirroring is enabled on a BlackDiamond 8800 series switch some of the incoming unicast ARP reply packets destined for ports on slot 6 MSM G8X are dropped When attempting an MSM failover using the run msm failover command after an ACL refresh failure the ACL process dies PD4 714733490 PD4 505226018 BGP PD4 605136780 Multicast PD4 676257961 Network Login PD4 690785443 PD4 692471986 QoS PD4 580590965 sFlow PD4 658290001 SNTP PD4 717148757 ACL blackhole entries installed during a refresh policy are not removed if a failover occurs during the refresh policy AS Path match conditions _ and may not provide the expected output when using the show bgp route as path command and when the conditions are used in an ACL Regular expressions containing multiple symbols do not work CRC errors are seen in multicast streams in a configuration that has load shared ports with member ports on different slots This issue is seen when the slot is removed and reinserted When MAC based network login and MSTP are enabled on a port the learned FDB is inconsistent Help for the configure traffic ingress queue q_test add egress queue q asd ports all command should be all ports instead of all cos queue The show configuration etmon co
22. BlackDiamond 10808 4 000 egress LSPs BlackDiamond 12800 R series 3 000 RSVP TE transit LSPs maximum number of BlackDiamond 10808 2 000 transit LSPs BlackDiamond 12800 R series 1 500 RSVP TE paths maximum number of paths BlackDiamond 10808 1 000 BlackDiamond 12800 R series 1 000 RSVP TE profiles maximum number of profiles BlackDiamond 10808 1 000 BlackDiamond 12800 R series 1 000 RSVP TE EROs maximum number of EROs per BlackDiamond 10808 64 path BlackDiamond 12800 R series 64 Spanning Tree maximum STPDs maximum All platforms 64 number of Spanning Tree Domains on port mode EMISTP Spanning Tree PVST maximum number of port All platforms 128 mode PVST domains ExtremeXOS 12 1 4 Installation and Release Notes Metric Product Limit Spanning Tree maximum number of multiple All platforms 64 spanning tree instances MSTI domains Spanning Tree maximum number of VLANs per All platforms 500 MSTI Spanning Tree maximum number of VLANs on All platforms 1 000 all MSTP instances Spanning Tree 802 1d domains maximum All platforms 1 number of 802 1d domains per port Spanning Tree number of ports maximum All platforms 2 048 number of ports including all Spanning Tree domains Spanning Tree maximum VLANs maximum dotld 560 number of STP protected VLANs dot lw 560 SSH number of sessions maximum number of All platforms 8 simultaneous SSH sessions Static
23. BlackDiamond 12800 series MSM 5 400 000 MSM 5R 400 000 MSM 6R 1 000 000 Summit X450 25 000 Summit X450a 25 000 BGP non unique routes maximum number of BlackDiamond 8800 series 25 000 non unique BGP routes LPM entries is limited 4 to support TCAM entries on a BlackDiamond Eller Cielito Pesiue 10808 MSM 1XL 2 000 000 MSM 1 900 000 BlackDiamond 12800 series MSM 5 900 000 MSM 5R 900 000 MSM 6R 2 000 000 Summit X450 25 000 Summit X450a 25 000 BGP multicast address family routes maximum BlackDiamond 8800 series 25 000 number of multicast address family routes BlackDiamond 10808 MSM 1XL 1 000 000 MSM 1 450 000 BlackDiamond 12800 series MSM 5 450 000 MSM 5R 450 000 MSM 6R 1 000 000 Summit X450 25 000 Summit X450a 25 000 ExtremeXOS 12 1 4 Installation and Release Notes Metric Product Limit BOOTP DHCP relay maximum number of BOOTP All platforms 4 or DHCP servers per virtual router CLEAR Flow total number of rules supported BlackDiamond 8800 c series 4 096 The ACL rules plus CLEAR Flow rules must be 7 less than the total number of supported ACLs SUR KESO 20e Note CLEAR Flow is not supported on e series switches and is only supported in a non stack configuration in the Summit family of switches Connectivity Fault Management CFM maximum All platforms 8 number or CFM domains CFM maximum number of CFM associations All platforms 4 094 CFM
24. BlackDiamond 12804 An error is displayed on the console and in the logs similar to the following Running Image ohdGetChassisInfo Incorrect Chassis type found defaulting to BIATHLON ohd_init_hw Error determining chassis info Starting Extremeware XOS 11 4 3b4 Copyright C 1996 2006 Extreme Networks All rights reserved Protected by US Patent Nos 6 678 248 6 104 700 6 766 482 6 618 388 6 034 957 6 859 438 6 912 592 6 954 436 Error Failed to connect CLI for 16 seconds login admin password ExtremeWare XOS Copyright C 2000 2006 Extreme Networks All rights reserved Protected by US Patent Nos 6 678 248 6 104 700 6 766 482 6 618 388 6 034 957 6 859 438 6 912 592 6 954 436 ExtremeXOS 12 1 4 Installation and Release Notes 12804 1 show log 05 02 2007 00 27 10 81 lt Info HAL Card Info gt MSM A Module in MSM A is operational 05 02 2007 00 27 10 39 lt Info AAA authPass gt MSM A Login passed for user admin through serial 05 02 2007 00 27 07 75 lt Erro Kern Error gt MSM A ohd_eeprom_read Error reading eeprom for slot 15 at offset 0 05 02 2007 00 27 07 75 lt Erro Kern Error gt MSM A ohd_eeprom_read Error reading eeprom for slot 15 at offset 0 05 02 2007 00 27 07 75 lt Erro Kern Error gt MSM A ohd_eeprom_access Error accessing device 1 Use the management VLAN virtual router to connect to your TFTP server by configuring an IP address on the management VLAN using the
25. ESSERE EES 69 BlackDiamond 10808 Switch Component Support ccccccceeecesecee cece eeseeeseecceeeeaeeeseeeeeenseees 69 BlackDiamond 8800 Series of Switches Component SUpPPOlt cccccseecseeeeeeeeeeeeeeeeeeeeeaeeeaes 71 BlackDiamond 12800 Series Switches Component Support c ccccsecceeeeseeeeeeeeeeeeeeeeeeeeneeees 72 Summit X150 and X350 Component Support ccccccccecceseceeeeee cece eeeeceeeeseeeseeeseeeeaeeeneeeaaes 72 Summit X250e Component Support cescssceccsivesccsavectsecc sivevssssievessteusseekensheuscnvavsateveosereveseeveess 72 Summit X450 Component Support cccceccsecseceeceeeceeeeeceeeeeeeeeseeseeeeeeeeeseeseeeeeeeeaeeseeeeeeeees 73 SEP Mini GBIC SuppOrbssivccssscccsvecssscwediavicevvidessauesctweeebsancsvancoswetcssauns syunccsveteobamveosancoseneeeays 74 XENPAK Module Support cccccccccsecsseceeceeceee eee eeseeseeee eee eee eeeeeeeeee eee eeseeseeseeeeeeaeseeeeeeeaeseesaes 77 XFP Module Sup pOrbscviscesi seceiheuve siete cavhocsvseudal get setabes dives assue cc EE EAEE EE EE O NEE EE EEE ri EE 79 Summit X150 and X350 Series Switch Software Details cccccccseccseeeceseceseceeceseeeseeeseeeeeeeeeeeeees 80 ExtremeXOS Command Line Support ccccccceececceeeceececcceeeeeeceeeeeeeeeeeesseeeeeeeeeesseseeeseeaeeeaes 81 Supported Commands on the Summit X150 and X350 Series Switches ccccceseeeeeeeaeeeeeees 81 Unsupported Commands on the Summit X150 and X350 Series Swit
26. Origin IGP Next Hop 80 0 0 1 Weight 1 AS Path 65070 144 Route 3 0 0 0 8 Origin IGP Next Hop 90 0 0 1 Weight 1 AS Path 65070 144 Route 3 0 0 0 8 Origin IGP Next Hop 60 0 0 1 Weight 1 AS Path 65070 144 Route 4 17 226 0 24 Origin IGP Next Hop 80 0 0 1 Weight 1 AS Path Route 4 17 226 0 24 Origin IGP Next Hop 90 0 0 1 Weight 1 AS Path 65070 144 Peer 80 0 0 69 LPref 100 90 10911 1239 80 Peer 90 0 0 69 LPref 100 90 10911 1239 80 Peer 60 0 0 69 LPref 100 90 10911 1239 80 Peer 80 0 0 69 LPref 100 Multipath Active Multipath Active Multipath BEST Active Multipath BEST Active 65070 14490 10911 3561 11853 6496 6496 6496 6496 Peer 90 0 0 69 LPref 100 Multipath Active 190 10911 3561 11853 6496 6496 6496 6496 AS Path 65070 14490 65070 14490 65070 14490 65070 14490 65070 14490 ExtremeXOS 12 1 4 Installation and Release Notes History This command was first available in ExtremeXOS 10 1 The any lt netMaskLen gt options were added in ExtremeXOS 11 0 This command required a specific license in ExtremeXOS 11 1 Platform Availability This command is available on platforms with the appropriate license For complete information about software licensing including how to obtain and upgrade your license and what licenses are appropriate for this feature see the ExtremeXOS Concepts Guide Appendix A ExtremeXOS Software Licenses
27. Output for the show platform ipv4mc group lt group address gt Command Contains an invalid Entry The output for the show platform ipv4Mc group lt group address gt command contains an invalid entry BD 10808 61 show platform ipv4Mc g 239 255 255 1 Total Entries 27 Index Type VrId Port Source Group PTI Vlan 004A6 gt O3E3A 3 invalid PD3 14127903 PD3 13538171 Egress Mirror Packets are Being Sent to Mirror Port in Link Down State Mirrored egress packets are being sent to the mirror port even when the port is in the link down state ExtremeXOS 12 1 4 Installation and Release Notes Table 32 Platform Specific and Feature PDs Continued PD Number Description BlackDiamond 12800 Series Switches PD3 187808062 Switch Does Not Show Warning Message for Down Revision MSM and I O Modules A BlackDiamond 12800 series switch does not show a warning message on the console for down revision MSM and I O modules after initialization PD3 24601141 802 1P Precedence Support Incoming 802 1P precedence is not supported when ports are used for vMAN PD3 125511903 System Fails with a Signal 10 Error When Running an MSM Failover A system failure occurs with a signal 10 error when performing a run msm failover immediately after the backup MSM is in sync PD3 130441271 PD4 281640171 Traffic Queues with Metering are Not Applied Correctly Traffic queues with metering are not applied
28. PD4 309933739 Configuring a VMAN ACL with invalid action modifiers does not show any errors Spanning Tree Protocol PD4 418743606 Adding a VLAN to STP domain sO and then enabing STP domain sO generates the PD4 332966643 following error Error Incorrect carrier vlan configuration of port 2 in stp domain s0 If you enable STP domain sO first and then add the VLAN to the STP domain the configuration is accepted Workaround Enable the STP domain first and then add the VLAN ExtremeXOS 12 1 4 Installation and Release Notes Resolved Issues in ExtremeXOS 12 1 2 17 The following issues were resolved in ExtremeXOS 12 1 2 17 The numbers shown in column one of the following table are for internal reference and can be ignored ExtremeXOS 12 1 includes all fixes up to and including ExtremeXOS 11 1 4 4 ExtremeXOS 11 2 3 3 ExtremeXOS 11 3 4 5 ExtremeXOS 11 4 4 7 ExtremeXOS 11 5 2 10 ExtremeXOS 11 6 4 11 through patch1 8 and ExtremeXOS 12 0 3 16 through patch1 13 For information on those fixes see the release notes for the specific release Table 57 Platform Specific and Feature PDs PD Number General PD4 334535100 Description Running the debug hal show version msm command generates the following system error on a BlackDiamond 8800 series switch with an MSM 48c in MSM A slot 08 14 2008 04 36 44 68 MSM A ahd_adm1066_cmd Error reading ADM1066 for slot 11 rc 1 PD4 281874747 PD3 192013071 The
29. PDs Continued PD Number Description Network Services PD3 42385251 When creating a large policy file on a BlackDiamond 10808 switch and applying the policy to a VLAN on egress if traffic is sent that attempts to hit the ACL rules and the next hop ARP entry is not yet learned the MSMs may stop responding vMAN PD3 203983381 In ExtremeXOS 12 0 3 when a BVLAN tag is changed a packet egressing the BVLAN does not reflect the changed tag Packets still egress the BVLAN using the original tag This problem applies to all vMANs create vman create bvlan and so on and occurs only if the BVLAN tag is changed and the BVLAN contains ports This does not apply to a BVLAN that is created without any ports Workaround Save the configuration and reboot the system Resolved Issues in ExtremeX0OS 12 1 0 29 The following issues were resolved in ExtremeXOS 12 1 0 29 The numbers shown in column one of the following table are for internal reference and can be ignored ExtremeXOS 12 1 includes all fixes up to and including ExtremeXOS 11 1 4 4 ExtremeXOS 11 2 3 3 ExtremeXOS 11 3 4 5 ExtremeXOS 11 4 4 7 ExtremeXOS 11 5 2 10 ExtremeXOS 11 6 4 11 through patch1 8 and ExtremeXOS 12 0 3 16 For information on those fixes see the release notes for the specific release Table 59 Platform Specific and Feature PDs PD Number Description MPLS PD3 188165546 PD3 120757801 On BlackDiamond 12800 series switches received MPLS packets
30. Port flapping and other problems can cause logs similar to the following when 802 1Q tagged packets are software forwarded for a VPLS service VLAN 12 15 2006 08 11 40 67 lt Erro Kern Error gt MSM A nettx_vpls_transmit 987 VPLS problems determining encapsulated packet lq tag for The logs are the result of other problems such as port flapping and will no longer appear when the other problems are corrected PD3 117148339 Enabling or disabling penultimate hop popping on a VLAN does not work if MPLS is enabled PD3 169466471 The show fdb vpls lt vpls_name gt command shows the entire FDB entry PD3 179426902 PD3 188166267 PD3 177361681 Existing MPLS forwarding data is not installed on newly inserted BlackDiamond 12800 series switches which can cause problems when receiving and transmitting MPLS packets on those I O modules Workaround Disable and enable MPLS PD3 135927701 The show vpls detail command does not display the updated counters RX Pkt and RX Bytes when using q to quit The counters are updated after running the complete command PD3 88153931 The ExtremeXOS route table and kernel route table show that an LSP next hop for a specific route is available However when ping or traceroute commands are run for a destination reached by the route the LSP next hop may not be used ExtremeXOS 12 1 4 Installation and Release Notes Table 58 Platform Specific and Feature
31. Summit X450 3 000 Summit X450a 3 000 PIM snooping maximum number of S G BlackDiamond 8800 series 1 024 entries programmed in the hardware Black Diamond S800 c scries 2 048 BlackDiamond 10808 12 000 BlackDiamond 12800 series 12 000 Summit series 1 024 PiM maximum routes maximum number of BlackDiamond 8800 series 1 024 S G entries installed in the hardware aed Denan CE0 cais 2 048 BlackDiamond 10808 12 000 BlackDiamond 12800 series 12 000 Summit series 1 024 PIM SSM maximum SSM routes maximum BlackDiamond 8800 series 1 024 Dries Mee Vaca eter in the hW BlackDiamond 8800 c series 2 048 BlackDiamond 10808 15 000 BlackDiamond 12800 series 15 000 Summit series 1 024 PIM maximum interfaces maximum number of All platforms 256 PIM active interfaces PIM maximum interfaces maximum number of All platforms 256 PIM snooping enabled interfaces Policy based routing PBR redundancy All platforms 32 maximum number of flow redirect and nexthops per each flow direct Private VLANs maximum number of BlackDiamond 8800 a c and e series superbe Aumes aminima Of one Fort with eight modules of 48 poris 383 BlackDiamond 10808 1 400 BlackDiamond 12800 series 1 400 Summit X450a and X450e 24 port with two port option card 25 without option card 23 Summit X450a and X450e 48 port with two port option card 49 without option card 47 Private VLANs maximum number of private All platforms 512 VLANs with an IP address on the n
32. Table 49 Platform Specific and Feature PDs PD Number General PD4 256803787 PD3 328904792 Description On a Summit X450a series switch software redundant ports work correctly even after multiple link flaps PD4 549308147 PD4 549927751 After uploading an ASCII configuration and then downloading the same conifguration the configuration changes are not applied properly if the default EAPS hellotime and failtime are modified Running diagnostics on a slot and then running the debug hal show sys health check command shows an incorrect bcmRX message PD4 526154880 CLI allows users to specify the vMANs created without using the learning domain keyword as part of the learning domain action in a policy file PD4 488646640 In some instances vMAN configuration commands are displaying as VLAN configuration commands in the output of the show configuration command For example configure vman vman2 qosprofile QP3 displays as configure vlan vman2 qosprofile QP3 PD4 488295907 For BlackDiamond 8800 and Summit platforms the ExtremeXOS CLI currently allows using the same vMAN Ethertype for both the primary and the secondary Ethertypes PD4 422347775 Interrupting the ping command initiated from an ExtremeXOS switch by pressing CTRL C may cause a cliMaster process to crash with signal 11 when a user exits that CLI session PD4 453278202 PD4 215198629 If you upgrade a non active partition on an E
33. The following message is shown in the log without stating which message was suppressed 07 21 2008 20 13 48 38 Slot 1 NI 07 21 2008 20 13 53 38 Slot 1 NI T 7697 messages suppressed T 8789 messages suppressed om sh je ah The log should also show which message was suppressed PD4 276815768 Enabling PIM snooping on a vMAN causes duplication of PIM control packets PD4 234942701 After a switch with PIM snooping enabled receives a PIM packet that includes the DR option the multicast manager process dies PD4 275662331 A multicast stream on a vMAN running PIM snooping intermittently stops As a result the PIM snooping entries are being flushed after the hold timer 105 expires even though there is a PIM hello exchange ExtremeXOS 12 1 4 Installation and Release Notes Table 57 Platform Specific and Feature PDs Continued PD3 210637311 Using MVR on a Summit and BlackDiamond 8800 a series e series or c series platforms configured with tagged subscribing VLANs may cause unexpected untagged packet forwarding and error level log messages such as 06 09 1920 00 08 49 87 lt Erro Kern IPv4Mc Error gt Slot 8 Del IPmc vlan 210 for 8 1 s G c1010104 e101000a IPMC 9 Entry not found Unable to unit 0 Workaround Assign an IP interface to each tagged subscriber VLAN PD3 209983742 When a slot on a BlackDiamond 8800 or SummitStack switch reboots with active Layer 3 IP multicast subscr
34. action mirror cpu and log do not work PD3 56605924 BGP PD3 41952658 CLEAR Flow PD3 95652911 PD3 95652994 Control Protocols PD3 84477402 PD3 75421071 Documentation PD3 201780134 Multiple egress vVMAN ACL rules with identical IF conditions but different egress ports cannot be distinguished Packets are going to be forwarded based on only one of the applicable rules BGP traps transmitted from a BlackDiamond or Summit X450 switch are missing the peer IP addresses When using the show clear flow command RL is not included in the Threshold Type with CN DT and DR When creating a CIST domain and then configuring the link type as point to point for CIST the link type configuration is lost when the uploaded configuration is downloaded The ethernet source address mask is not supported in ExtremeXOS 12 0 as stated in the ExtremeXOS 12 0 Concepts Guide It is supported in ExtremeXOS 12 1 ExtremeXOS 12 1 4 Installation and Release Notes Table 58 Platform Specific and Feature PDs Continued PD Number Description EAPS PD3 176462601 PD3 86015057 EAPS takes approximately 120 milliseconds to 160 milliseconds to recover after restoring a link failure The following error message is displayed in the log when disabling port sharing on ring ports 08 01 2006 19 49 32 55 lt Crit vlan err criticalInfo gt Critical Info handleVMngrProtoIfSetState procName eaps protolId 0x80 not registered vpif gt
35. and ports Default Enabled Usage Guidelines With autonegotiation enabled the Summit family of switches and the BlackDiamond 8800 series switches advertise the ability to support pause frames This includes receiving and reacting to stopping transmission pause frames Use this command to disable the processing of IEEE 802 3x pause flow control messages received from the remote partner Disabling rx pause processing avoids dropping packets in the switch and allows for better overall network performance in some scenarios where protocols such as TCP handle the retransmission of dropped packets by the remote partner To disable RX flow control TX flow control must first be disabled Refer to the disable flow control tx pause ports command If you attempt to disable RX flow control with TX flow control enabled an error message is displayed Example The following command disables the rx flow control feature on ports 5 through 7 on a Summit switch disable flow control rx pause ports 5 7 History This command was first available in ExtremeXOS 12 1 3 Platform Availability This command is available on the BlackDiamond 8800 series modules and the Summit family of switches ExtremeXOS 12 1 4 Installation and Release Notes disable flow control tx pause ports disable flow control tx pause ports lt port_list gt all Description Disables the transmission of pause frames Syntax Description port_list Specifies
36. are running on MSM A reboot msm a if you are running on MSM B Finally save the configuration on both MSMs by using the command save configuration Using a Rev 10 or later BlackDiamond 10808 MSM 1 or MSM 1XL oO dd note To use a Rev 10 or later MSM 1 or MSM 1XL module you must upgrade both the active and alternate images with the latest ExtremeWare 11 1 3 or later software image To determine which version of MSM you have installed in your switch use the show version command If you have a Rev 9 or earlier MSM the show version command output will look like this MSM A 804015 00 09 0414F 00728 Rev 9 0 BootROM 1 0 1 5 IMG If you have a Rev 10 or later MSM the show version command output will look like this MSM A 804407 00 10 0505F 00429 Rev 10 0 BootROM 1 0 1 5 IMG Complete show version command output with Rev 10 MSMs will look like this BD 10808 2 BD 10808 2 show version Chassis 804300 00 03 0324X 00026 Rev 3 0 MSM A 804407 00 10 0505F 00429 Rev 10 0 BootROM 1 0 1 5 IMG MSM B 804407 00 10 0505F 00431 Rev 10 0 BootROM 1 0 1 5 IMG Image ExtremeXOS version 11 1 3 3 v11133 by release manager on Thu Mar 31 19 12 57 PST 2005 BootROM 1 0 1 7 BD 10808 3 ExtremeXOS 12 1 4 Installation and Release Notes Installing an ExtremeXOS Module An ExtremeXOS module has functionality that supplements a core image You will download and install a module onto an already installed core image T
37. based routing PBR with multiple hops with health checking Fast Reroute Recovery FRR FRR for RSVP TE is introduced in Extreme XOS 12 1 1 as an LSP protection capability as defined in RFC 4090 Testing continues for this feature to stabilize and optimize this capability for deployment in production networks At this time FRR should not be enabled in a production network To protect against accidentally enabling this feature in a production network the CLI command enable mpls rsvp te fast reroute is hidden If you want to test FRR in a lab environment and provide feedback contact Extreme Networks Technical Support The FRR feature will be supported for production networks in a future release of ExtremeXOS software once testing is complete Provider Backbone Bridging Traffic Engineering PBB TE 802 lag IP security enhancements m Added source IP lockdown counter m DHCP bindings preservation across reboots New Hardware Supported in ExtremeXOS 12 1 1 4 The following modules are supported in ExtremeXOS 12 1 1 4 BlackDiamond 8800 c series modules MSM 48c 10G1Xc G8Xc G48Tc with optional S POE for inline power G48Xc G24Xc 10G8Xc 10G4Xc G48Te2 with optional S POE for inline power Summit X350 Supported Hardware Refer to the Extreme Networks hardware installation guides for more information about supported hardware The following tables list the software filenames for the hardware that requires software BlackDiamond 1080
38. c Applies only if all enabled BlackDiamond I O modules are BlackDiamond 8800 c series modules d Effective capacity varies based on actual IP addresses and hash algorithm selected but is higher for BlackDiamond 8800 c series modules compared to BlackDiamond 8800 a series and e series modules ExtremeXOS 12 1 4 Installation and Release Notes Open Issues Known Behaviors and Resolved Issues This chapter describes items needing further clarification known behaviors that might not be intuitive and resolved issues The numbers shown in column one of the following tables are for internal reference and can be ignored This chapter contains the following section Open Issues on page 134 Known Behaviors on page 148 Resolved Issues in ExtremeXOS 12 1 4 patch1 9 on page 153 Resolved Issues in ExtremeXOS 12 1 4 patch1 8 on page 153 Resolved Issues in ExtremeXOS 12 1 4 patch1 7 on page 154 Resolved Issues in ExtremeXOS 12 1 4 patch1 6 on page 154 Resolved Issues in ExtremeXOS 12 1 4 patch1 5 on page 155 Resolved Issues in ExtremeXOS 12 1 4 patch1 4 on page 155 Resolved Issues in ExtremeXOS 12 1 4 patch1 3 on page 156 Resolved Issues in ExtremeXOS 12 1 4 patch1 2 on page 156 Resolved Issues in ExtremeXOS 12 1 4 patch1 1 on page 157 Resolved Issues in ExtremeXOS 12 1 4 on page 158 Resolved Issues in ExtremeXOS 12 1 3 patch1 9 on page 159 Resolved Issues in ExtremeXOS 12 1 3 patch1 8 on page 160 Resolved Issues in ExtremeXOS 12 1 3 patch1 6
39. command to save the configuration in the upgraded image Upgrading ExtremeXOS on a Summit X250e Upgrade a Summit X250e to ExtremeXOS 12 1 4 as follows 1 Save your configuration to a backup configuration file using the save configuration lt configuration_file name gt command You must save your configuration to a backup configuration file in order to revert to your currently running image if the need arises Run the show version command to verify the BootROM version currently running on your switch If you are not running BootROM version 1 0 3 0 upgrade the BootROM using the following command download bootrom 10 60 116 11 pmon_Combined_1_0_3_0 xtr vr vr mgmt Determine your current active image partition by running the show switch command The Image Booted field shows the current active partition Download the ExtremeXOS 12 1 4 image to the alternate partition using the following command download image lt ipaddress gt lt filename gt vr lt vrname gt lt image partition gt For example if your current image is running in the primary partition download the new image in the secondary partition download image 10 60 116 11 summitX 12 1 4 xos vr vr mgmt secondary Run the show switch command again to determine that the image is downloaded into the partition you have specified Reboot the switch Use the reboot command to reboot the switch When the switch comes up run the save configuration command to save the configu
40. configure netlogin vlan net log enable netlogin mac enable netlogin ports 1 10 mac configure netlogin ports 1 mode port based vlans configure netlogin ports 1 no restart configure netlogin ports 2 mode port based vlans configure netlogin ports 2 no restart configure netlogin add mac list 00 02 b3 ed 42 44 48 encrypted canrli configure netlogin add mac list 00 0f 1f fe d6 25 48 encrypted canrli configure netlogin add mac list 00 16 76 dd 3b al 48 encrypted canrli Module stp configuration create stpd s10 configure stpd sl configure stpd sl 0 0 add configure stpd s10 0 0 add add add configure stpd sl configure stpd sl stpd sl stpd sl stpd s1 configure configure configure configure stpd s10 ports configure stpd s10 ports enable stpd s10 ports 1 configure stpd s10 ports configure stpd s10 ports configure stpd s10 ports configure stpd s10 ports configure stpd s10 ports enable stpd s10 ports 2 configure stpd s10 ports configure stpd s10 ports configure stpd s10 ports configure stpd s10 ports configure stpd s10 ports enable stpd s10 ports configure stpd s10 ports configure stpd s10 ports configure stpd s10 ports configure stpd s10 ports configure stpd s10 ports enable stpd s10 ports 48 enable stpd s10 ports ports ports mode dotlw vlan vlan vlan vlan v10 v10 v10 v10 1 dotid 2 dotid 47 dotid 48 dotlid ports ports ports ports mode dotid 1 cost auto 1 port priorit
41. disable jumbo frame ports command is allowed on Summit switches and BlackDiamond 8800 module ports with the exception of original Summit X450 series switches and original BlackDiamond 8800 modules On all other Summit switches and BlackDiamond 8800 modules the command is properly executed but the configuration is not saved across switch reboots PD4 300801557 The following erroneous Event Management System EMS message is displayed even when the memory level of a switch is at a safe level 07 15 2008 05 12 23 91 MSM A OS Memory KBytes Total Free aspenHCErrorHandler Card 2 is low on 110208 16040 PD4 266013210 PD3 192633919 A switch experiences an async queue deadlock which is followed by memory depletion PD4 328904792 On a Summit X450a series switch software redundant ports work correctly even after multiple link flaps PD4 294933687 PD4 286201111 Connectivity Fault Management CFM prematurely reports a connectivity fault before initializing I O modules and links A remote end point is reported as expired during boot up which is logged before a link to the remote end point is brought up When performing a PIM SM performance test using 4 096 G groups the following error is displayed hal Reached maximum otp index allocation PD3 209052145 PD3 209042091 BGP PD3 211438941 PD4 245719933 DHCP PD4 289525161 Diagnostics PD3 74554921 When two 1OOBASE T FX and FX LX GBI
42. e series 8 192 BlackDiamond 8800 system 128 000 Summit X150 and X350 series 8 192 Summit X250e 8 192 Summit X450 16 384 Summit X450a 16 384 Summit X450e 8 192 SummitStack 128 000 ExtremeXOS 12 1 4 Installation and Release Notes Metric Product Limit Hierarchical 2S maximum number of ingress BlackDiamond 12800 R series 4 076 only traffic queues per system For 20XTR first 10 ports ranges from 1 to 10 are UNIT I second 10 ports ranges from 11 to 20 are UNIT II for 10 Gig slot each port is one UNIT Hierarchical 2S maximum number of ingress BlackDiamond 12800 R series 4 076 traffic queues with egress shaping allowed per switch Hierarchical 2S maximum number of egress BlackDiamond 12800 R series 4 076 only traffic queues allowed per switch Hierarchical QS maximum number of traffic BlackDiamond 12800 R series 4 076 queues attach per port IGMP sender maximum number of IGMP BlackDiamond 8800 c series 2 048 sendas per STNG I BlackDiamond 8800 series 1 024 BlackDiamond 10808 15 000 BlackDiamond 12800 series 15 000 Summit series 1 024 IGMP snooping per VLAN filters maximum Summit X150 448 number of VLANs supported in per VLAN IGMP Summit X250e 448 snooping mode Summit X350 448 Summit X450 60 Summit X450a 1 000 Summit X450e 448 BlackDiamond 8800 original 60 BlackDiamond 8800 c series 2 000 BlackDiamond 8800 a series 1 000 BlackDiamond 8800 e series
43. following command configure mgmt ipaddress 192 168 1 134 24 Enter a default gateway using the following command configure iproute add default 10 201 1 1 vr VR Mgmt d note The default VLAN has no ports because it does not recognize the chassis Test which virtual router you will need to specify when you download the image to your switch by using the following command and your own IP address ping vr vr mgmt 192 168 0 12 This command must successfully reach your TFIP server in order to download the image Download and install the image to the switch using the following command download image 192 168 0 12 bd12k 12 1 4 xos vr vr mgmt When the switch returns the following message Do you want to install image after downloading y yes n no lt cr gt cancel Answer y to install the image after downloading Use the reboot command to reboot the switch Run the show switch command Verify that the SysName and System Type read BD 12802 and that the image is specified as 12 1 4 SysName BD 12802 SysLocation SysContact support extremenetworks com 1 888 257 3000 System MAC 00 04 96 31 A2 40 System Type BD 12802 SysHealth check Enabled Normal Recovery Mode All System Watchdog Enabled Current Time Thu May 3 11 31 07 2007 Timezone Auto DST Disabled GMT Offset 0 minutes name is UTC Boot Time Thu May 3 11 26 38 2007 Boot Count 11 Next Reboot None scheduled System UpTime 4 minutes
44. for the directly attached subnet and the other is a host route for the interface itself This issue affects the recommended value for the configure iproute reserved entries command See the ExtremeXOS 12 1 2 Command Reference Guide for new usage guidelines PD3 190363671 Hot Swapping PSUs Generates an Error Message The following error message is displayed while hot swapping PSUs Unable to read PSU 2 FRU data Try reinserting PSU more quickly Workaround Remove and reinsert the PSU quickly Insert the PSU in a single continuous motion with a firm push PD3 207678214 User Configured Banner Remains Active The user configured banner remains active when rebooting a switch without first saving the configuration PD3 207576821 Upgrading the BootROM to the Minimum Version on an MSM ER is Not Working Correctly Upgrading the BootROM 1 0 1 8 on an MSM 6R running ExtremeXOS 12 0 2 25 software is not working correctly If you run the install firmware command and then reboot the switch the BootROM version remains 1 0 1 8 PD3 206179541 Most L3 Traffic Slow Path Forwarded if IP Route Compression is Enabled Enabling IP route compression on a BlackDiamond 10808 or 12800 series switch that has already reached the maximum IPv4 routing entries in hardware might cause slow path forwarding for some of the L3 traffic PD3 202580681 Some L3 Traffic May Temporarily Be Slow Path Forwarded When IP Route Compression is Enabled
45. group it does not inherit the default route origination configuration from the peer group Also default route origination for a neighbor and the associated peer group can be different If a policy is configured and specified in the command a default route can be originated only if there is a route in the local BGP RIB that matches the policy s match rules The default route s attribute can be modified using the same policy file by including statements in the set block of the policy Example The following command enables the origination and advertisement of default routes for IPv4 unicast traffic for all BGP peer nodes enable bgp neighbor all originate default ExtremeXOS 12 1 4 Installation and Release Notes History This command was first available in ExtremeXOS 12 1 3 Platform Availability This command is available on platforms with the appropriate license For complete information about software licensing including how to obtain and upgrade your license and what licenses are appropriate for this feature see the ExtremeXOS Concepts Guide Appendix A ExtremeXOS Software Licenses ExtremeXOS 12 1 4 Installation and Release Notes enable bgp peer group originate default enable bgp peer group lt peer group name gt address family ipv4 unicast ipv4 multicast originate default policy lt policy name gt Description Enables the origination and advertisement of default routes to all BGP neighbors in the
46. is used to deny vMAN traffic with unknown unicast multicast and broadcast destination addresses the egress ACL cannot deny the traffic PD3 208402260 If you create a telnet access profile using the destination address match statement the destination address statement is not evaluated Other match statements within the entry are evaluated If there are no other statements then the action is taken regardless of whether the destination address is a match PD3 135380560 PD3 134870425 For Summit X450 and BlackDiamond 8800 switches installing unconfiguring and refreshing a large number of static or dynamic ACL rules with meters may take a long time Workaround Install ACL rules with meters in the order higher precedence first and uninstall ACL rules with meters in the order of lower precedence first PD3 208751163 MSM B reboots when applying 20 000 ACL rules with 20 000 ingress queues PD3 135200936 When an ACL policy file containing meters associated with ACL rules is applied to a port the system should verify that the meters are present before installing the ACL policy file If meters are not present the system should generate an appropriate error message and the ACL policy file should not be installed PD3 121018177 Action redirect port is not supported on egress ports Even if redirect is applied to an egress port while redirect port has no effect on egress traffic the counter should work c
47. modes of operation 802 1D and 802 1w e dotld This mode is reserved for backward compatibility with previous STP versions BPDUs are sent running in 802 1D mode This encapsulation mode supports the following STPD modes of operation 802 1D 802 1w and MSTP In PVST and EMISTP modes carrier VLAN restrictions are imposed see the ExtremeXOS Concepts Guide for more information about carrier VLANs If all ports are in dotld mode there are no carrier VLAN restrictions dd NOTE STP domains should be enabled after completing safeguard configurations Each netlogin port should be enabled with safeguard If you add a new netlogin port to an already enabled STP domain disable the spanning tree domain and then enable it again Refer to the following configurations when running STP and netlogin on an edge port Module vlan configuration configure vlan default delete ports 1 50 create vlan net log create vlan v10 configure vlan v10 tag 10 configure vlan v10 add ports 1 48 untagged configure vlan v10 ipaddress 192 168 10 254 255 255 255 0 Module aaa configuration create netlogin local user 0002b3ed4244 encrypted 9xSkxd 3gF45Q0a9vhdnzdWPFr7Vs0 create netlogin local user 000f1ffed625 encrypted P1G8rd SADwsxR2U9PMgLLOfL02U4 create netlogin local user 001676dd3bal encrypted 53inVd 14u9aDnRAgDMbXnBNapvki1 ExtremeXOS 12 1 4 Installation and Release Notes Module netLogin configuration
48. now MSM A MSM MSM A MSM B Current State MASTER BACKUP In Sync Image Selected primary primary Image Booted primary primary Primary ver 12 172 12 de 2 Secondary ver 11 4 1 4 11 4 1 4 Dual MSM Systems with Different Images Present If you have a dual MSM system that has different images on the MSMs you will need to modify the upgrade procedure One situation where you might have different images installed is when you add an MSM that has been in storage to your chassis either for the first time or as a replacement You will only need to do the following procedure if one of the MSMs is running an image earlier than 11 0 0 and the images are different on the two MSMs earlier versions of the software are unable to automatically synch up the configurations Follow the directions for upgrading the switch and continue with step 6 When you download the image as described in step 6 Download and install the image to the switch you will be asked Do you want to install image after downloading y yes n no lt cr gt cancel ExtremeXOS 12 1 4 Installation and Release Notes Answer n for no so that the image will not be installed after downloading Next manually install the image using the following command install image bd10k 12 1 4 xos Now the two MSMs have the same image installed but may not have the same configurations Reboot the secondary MSM using one of the following commands reboot msm b if you
49. number of MAC address learned by a Black Biamend 12800 R ceres 60 000 switch in an evenly distributed hierarchical VPLS Note Increasing the number of spokes per VPLS will decrease the maximum number of MAC addresses that can be learned VPLS MAC addresses in a fully meshed VPLS BlackDiamond 10808 100 000 network maximum number of MAC addresses learned by a switch in an evenly distributed BlackDiamond 12800 R series 80 000 fully meshed VPLS network VPLS VPNs maximum number of VPLS virtual BlackDiamond 10808 500 point to private networks per switch point BlackDiamond 12800 R series 500 point to point VPLS peers maximum number of VPLS peers BlackDiamond 10808 16 pegenn BlackDiamond 12800 R series 16 VPLS pseudo wires maximum number of VPLS BlackDiamond 10808 1 000 seus Mes ipedewiten BlackDiamond 12800 R series 500 VRRP maximum instances maximum number All platforms with Advanced Edge license 128 of VRRP supported VLANs for a single switch or above ExtremeXOS 12 1 4 Installation and Release Notes Metric Product Limit VRRP maximum VRID maximum number of All platforms with Advanced Edge license 7 unique VRID numbers per switch or above VRRP maximum VRIDs per VLAN maximum All platforms with Advanced Edge license 7 number of VRIDs per VLAN or above VRRP maximum ping tracks maximum number All platforms with Advanced Edge license 8 of ping tracks per VLAN or above VRRP maxim
50. on page 161 Resolved Issues in ExtremeXOS 12 1 3 patch1 4 on page 163 Resolved Issues in ExtremeXOS 12 1 3 patch1 2 on page 165 Resolved Issues in ExtremeXOS 12 1 3 on page 167 Resolved Issues in ExtremeXOS 12 1 2 17 patch1 17 on page 170 Resolved Issues in ExtremeXOS 12 1 2 17 patch1 15 on page 171 Resolved Issues in ExtremeXOS 12 1 2 17 patch1 12 on page 172 Resolved Issues in ExtremeXOS 12 1 2 17 patch1 10 on page 173 Resolved Issues in ExtremeXOS 12 1 2 17 patch1 7 on page 174 Resolved Issues in ExtremeXOS 12 1 2 17 patch1 4 on page 174 Resolved Issues in ExtremeXOS 12 1 2 17 patch1 3 on page 176 Resolved Issues in ExtremeXOS 12 1 2 17 on page 177 Resolved Issues in ExtremeXOS 12 1 1 4 on page 180 Resolved Issues in ExtremeXOS 12 1 0 29 on page 183 ExtremeXOS 12 1 4 Installation and Release Notes Open Issues Following are the open issues for supported features in ExtremeXOS 12 1 They are organized into the following sections Table 32 Platform Specific and Feature PDs PD Number General PD3 210656503 PD4 331224298 Description Log Filter With a Target Session Cannot be Deleted A log filter configured with a target session cannot be deleted after logging out of a switch and then logging back in PD4 254500398 Each IP Address Configured VLAN Occupies Two LPM Hardware Entries Instead of One Each IP address configured VLAN occupies two longest prefix match LPM hardware entries instead of one One entry is
51. one or more ports or slots and ports Default Disabled Usage Guidelines Use this command to stop the transmission of flow control pause frames and revert to the default Example The following command disables the tx flow control feature on ports 5 through 7 on a Summit switch disable flow control tx pause ports 5 7 History This command was first available in ExtremeXOS 12 1 3 Platform Availability This command is available on the BlackDiamond 8800 series modules and the Summit family of switches ExtremeXOS 12 1 4 Installation and Release Notes enable flow control rx pause ports enable flow control rx pause ports lt port_list gt all Description Enables the switch to process received pause frames Syntax Description port_list Specifies one or more ports or slots and ports Default Enabled Usage Guidelines Use this command to configure the switch to return to the default behavior of processing received pause frames Example The following command enables the tx flow control feature on ports 5 through 7 on a Summit switch enable flow control rx pause ports 5 7 History This command was first available in ExtremeXOS 12 1 3 Platform Availability This command is available on the BlackDiamond 8800 series modules and the Summit family of switches ExtremeXOS 12 1 4 Installation and Release Notes enable flow control tx pause ports enable flow control tx pause ports lt port_li
52. specific release Table 51 Platform Specific and Feature PDs PD Number General PD4 576392442 PD4 576392422 Description Memory usage on data blocks set to size 128 continues to increase on standby stacking nodes PD4 543585023 PD3 121149464 Log timestamps in the show log command output now match the time displayed in the show switch command output PD4 376308672 Packets other than L2 switched are egressing with the wrong VLAN tag on the ports in the I O module that are part of cross module load share and are hot swapped PD4 552244804 PD4 552244726 Removing a master MSM results in a 5 6 second packet loss for port traffic going through the master MSM backplane PD4 498613775 A HAL crash with signal 11 error occurs on stacking platforms after running diagnostics on one of the stacking nodes PD4 572997711 PD4 471535375 BlackDiamond 12 PD4 573244730 PD4 320452728 On switches with dual MSMs when running the upload debug command the EPM process may die with a signal 11 error 800 Series Switch Running CLI commands on a BlackDiamond 12800 series switch with an MSM 6R module shows an intermittent delay of 30 to 60 seconds during command execution PD4 589865012 PD4 456860808 ACL PD4 556568561 When reinserting a XENPAK module in a BlackDiamond 12800 or 10800 series switch it may be shown as unsupported L4 access control list ACL rules are also being applied t
53. stack ExtremeXOS 12 1 4 Installation and Release Notes Table 32 Platform Specific and Feature PDs Continued PD Number Description PD3 126650411 Stackable Systems with Two or More Nodes may Experience Random VRRP Master Backup Flapping A stackable system with two or more nodes may experience random VRRP master backup flapping issues after an MSM failover when configured with the maximum 128 VRRP instances using the minimum advertisement interval of 100ms and maximum tracking entries System Related PD3 28577971 Show Log Error Messages Messages stored in NVRAM are in encoded format To restore the ASCII text of a message the version of ExtremeXOS loaded must be able to interpret the data written prior to reboot When the encoded format for a particular message cannot be interpreted by the version of ExtremeXOS currently loaded the messages are displayed in the following format 03 21 2005 17 15 37 36 lt UNKNW epm 28 gt NO MESSAGE DECODE Missing component epm v24 2 DUMP 00 00 2C 00 01 FF FF FF FF 00 00 00 95 42 3F 71 BY ee ee ee ea B q DUMP 10 00 14 C3 C1 00 11 00 1C 01 FF 00 08 65 70 6D 00 A oe gl da ie ada epm DUMP 20 08 FF 00 OC 00 18 00 02 65 70 6D 00 VRRP PD3 202801091 VRRP Master Accepting Packets Addressed to a Virtual IP Address A VRRP master should not accept or respond to packets addressed to a virtual IP address associated with a virtual router if the master is not the IP ad
54. static routes The address family to which the IGP routes is exported BGP supports two address families IPv4 Unicast and IPv4 Multicast If no address family is specified IPv4 unicast is the default Usage Guidelines The exporting of routes between any two routing protocols is a discreet configuration function For example you must configure the switch to export routes from OSPF to BGP and if desired you must configure the switch to export routes from BGP to OSPF You must first configure both protocols and then verify the independent operation of each Then you can configure the routes to export from OSPF to BGP and the routes to export from BGP to OSPF Similarly for BGP and ISIS or BGP and RIP You can use policies to associate BGP attributes including Community NextHop MED Origin and Local Preference with the routes Policies can also be used to filter out exported routes ExtremeXOS 12 1 4 Installation and Release Notes Using the export command to redistribute routes complements the redistribution of routes using the configure bgp add network command The configure bgp add network command adds the route to BGP only if the route is present in the routing table The enable bgp export command redistributes an individual route from the routing table to BGP If you use both commands to redistribute routes the routes redistributed using the network command take precedence over routes redistributed using the export command Ex
55. the clear cpu utilization command even if process CPU utilization goes above the threshold value PD4 757850297 PD4 630233676 After performing a hitless upgrade the show version command output still shows the old master filename not the new image However the show switch command output shows the correct image PD4 752699185 Untagged vMANs in a LAG cause tagged vMANs to stop forwarding PD4 701099735 When running the disable enable sys health check slot 2 command on an empty slot a BlackDiamond 10808 logs the following warnings show log lt Info cli logLocalCm gt MSM A lt Info cli logLocalCmd gt MSM A serial admin en slot 2 lt Info cli logLocalCmd gt MSM A serial admin disable slot 2 lt Warn AAA authFail gt MSM A Login failed for user admin through telnet 10 255 44 27 lt Warn HAL Card Warning gt MSM A initialized Caller 0x4832f0 Parml1 serial admin cle slot 2 Function pointer is not 0x2 Parm2 0x0 ExtremeXOS 12 1 4 Installation and Release Notes Table 47 Platform Specific and Feature PDs Continued PD4 688252511 Some hosts are no longer reachable after removing an active MSM B in a cross module link aggregation setup Workaround Disable and re enable the load shared port PD4 752568607 PD3 184290391 An initialization error causes an invalid IPML peer to be used on the initial call to dsGetEntryByAttr PD4 541064246 When configuring rate limit
56. to configure the monitoring for each member port You can configure each member port to track a particular IP address but only one IP address per member port To display the monitoring configuration for a health check LAG use the show sharing health check command To display the link aggregation configured on a switch use the show ports sharing command Example The following commands configure four different member ports configure sharing health check member port 10 add track tcp 10 configure sharing health check member port 11 add track tcp 10 configure sharing health check member port 12 add track tcp 10 configure sharing health check member port 13 add track tcp 10 1 tep port 23 2 tep port 23 gt 4 PPR R PRPRPPR When the TCP port seconds or counts are not specified they default to the values described in the Syntax Description ExtremeXOS 12 1 4 Installation and Release Notes History This command was first available in ExtremeXOS 12 1 3 Platform Availability This command is available on all platforms ExtremeXOS 12 1 4 Installation and Release Notes configure sharing health check member port delete tcp tracking configure sharing health check member port lt port gt delete tcp tracking lt IP Address gt tcp port lt TCP Port gt Description Unconfigures monitoring for each member port of a health check LAG Syntax Description port Specifies the member port IP Addr
57. vlan lt vlan_name gt ports lt port_list gt This affects BlackDiamond 8800 series and Summit X450 a series and X450 e series switches only PD3 161152153 A switch experiences high CPU usage and logs an error message when running a RIP process when an snmpwalk is performed even though RIP is globally disabled 07 12 2007 19 47 43 10 lt Info EPM cpu gt MSM A CPU utilization monitor process rip consumes 99 CPU PD3 154525838 IP Unicast PD3 192315271 PD3 182815070 IS IS PD3 206929752 Mirroring PD3 208247531 MPLS PD3 210216393 Multicast PD3 207976461 A BlackDiamond 8800 switch with a 10G4X module or a Summit X450 switch with an XGM 10 Gigabit module may drop duplicate loopback packets on 10 Gigabit ports when PIM is enabled while load sharing is configured and IP multicast is present When a switch is configured for proxy ARP with the always keyword the switch will not respond to a gratuitous ARP request it will only respond to ARP requests The ExtremeXOS implementation of IS IS supports draft ietf isis restart O2 As a result IS IS graceful restart vendor interoperability is limited to devices that support draft ietf isis restart O3 or earlier A BlackDiamond 12800 switch cannot mirror more than 2G of traffic for egress mirroring Doing so may be cause RX errors and the switch to reboot This is a hardware limitation for the BlackDiamond 12800 switch for egress mirroring When configuring a s
58. vr mgmt and TFIP server 192 168 0 12 substitute your own virtual router and IP address when you run the command download image 192 168 0 12 bd10k 12 1 4 ssh xmod vr vr mgmt lt partition gt primary or secondary You will be asked Do you want to install image after downloading y yes n no lt cr gt cancel Answer y for yes so that the image will be installed after downloading 4 Run the run update command Run the following command run update The run update command starts up the processes associated with the new module and makes them available to the system You should now be able to run the commands associated with SSH2 You can verify that the SSH2 module is running by issuing the following command show process If SSH2 is running you will see a process named exsshd listed You can then configure and enable SSH2 on the switch ExtremeXOS 12 1 4 Installation and Release Notes You can also verify that the SSH2 module is installed by issuing the following command show management If the SSH module is installed you will see text similar to the following SSH access Disabled Key invalid tcp port 22 vr all If the SSH module is not installed you will see text similar to the following SSH Access ssh module not loaded Uninstalling an SSH Module To uninstall the SSH module you must first terminate the THTTPD process 1 Run the terminate process thttpd graceful command This terminates the THTTPD process
59. 0 Pri 3 QP4 MinBw 0 MaxBw 100 Pri 4 QP5 MinBw 0 MaxBw 100 Pri 5 QP6 MinBw 0 MaxBw 100 Pri 6 QP7 MinBw 0 MaxBw 100 Pri 7 QP8 MinBw 0 MaxBw 100 Pri 8 Ingress Rate Shaping support IQP1 2 IQP1 MinBw 0 MaxBw 100 Pri 1 IQP2 MinBw 0 MaxBw 100 Pri 2 Ingress IPTOS Examination Disabled Egress IPTOS Replacement Disabled Egress 802 1p Replacement Disabled NetLogIin Disabled Smart redundancy Enabled Software redundant port Enabled Primary La Redundant 1 2 Redundant link configuration Off autopolarity Enabled ExtremeXOS 12 1 4 Installation and Release Notes dd note On the BlackDiamond 10808 switch the screen displays both ingress and egress QoS settings The 10Gbps ports have 8 ingress queues and the 1 Gbps ports have 2 ingress queues Refer to the ExtremeXOS Concepts Guide for more information on ingress queues or bi directional rate shaping The BlackDiamond 12800 series switch does not support ingress QoS settings BlackDiamond 12800 R series switch only The following command displays more specific information for slot 2 port 1 on a BlackDiamond 12800 R series switch show ports 2 1 information detail Following is sample output from this command Port 221 Virtual router VR Default Type NONE Random Early drop Unsupported Admin state Enabled with 10G full duplex Link State Ready Link Counter Up 0 time s VLAN cfg Name Default
60. 0 000 MSM 5R 120 000 MSM 6R 180 000 Summit X450 and X450a 5 000 IS IS IPv4 L2 routes recommended maximum BlackDiamond 8800 series 25 000 number of IS IS Level 2 routes BlackDiamond 10808 MSM 1 120 000 MSM 1XL 180 000 BlackDiamond 12800 series MSM 5 100 000 MSM 5R 120 000 MSM 6R 180 000 Summit X450 and X450a 5 000 IS IS IPv4 L1 routes in an L1 L2 router BlackDiamond 8800 series 20 000 recommended maximum number of IS IS Level 1 routes in an L1 L2 IS IS router BlackDiamond 10808 MSM 1 20 000 MSM 1XL 25 000 BlackDiamond 12800 series MSM 5 20 000 MSM 5R 20 000 MSM 6R 25 000 Summit X450 and X450a 3 000 IS IS IPv6 L1 routes in an L1 router BlackDiamond 8800 series 10 000 recommended maximum number of IS IS Level 1 routes in a Level 1 IS IS router BlackDiamond 10808 MSM 1 30 000 MSM 1XL 65 000 BlackDiamond 12800 series MSM 5 30 000 MSM 5R 40 000 MSM 6R 65 000 Summit X450 and X450a 5 000 ExtremeXOS 12 1 4 Installation and Release Notes Metric Product Limit IS IS IPv6 L2 routes recommended maximum BlackDiamond 8800 series 10 000 number of IS IS Level 2 routes BlackDiamond 10808 MSM 1 30 000 MSM 1XL 65 000 BlackDiamond 12800 series MSM 5 30 000 MSM 5R 40 000 MSM 6R 65 000 Summit X450 and X450a 5 000 IS IS IPv6 L1 routes in a L1 L2 router BlackDiamond 8800 series 10 000 recommended maximum number of IS IS Level 1 routes in a L1 I2 router BlackDiamond 10808 MSM 1 15 000 MSM 1XL 25 0
61. 00 BlackDiamond 12800 series MSM 5 15 000 MSM 5R 15 000 MSM 6R 25 000 Summit X450 and X450a 3 000 IS IS IPv4 IPv6 L1 routes in an L1 router BlackDiamond 8800 series 20 000 recommended maximum number of IS IS Level 1 routes in a Level 1 IS IS router The numbers BlackDiamond 10808 documented are based on 50 IPv4 routes and MSM 1 60 000 50 IPv6 routes MSM 1XL 130 000 BlackDiamond 12800 series MSM 5 30 000 MSM 5R 60 000 MSM 6R 130 000 Summit X450 and X450a 5 000 IS IS IPv4 IPv6 L2 routes in an L2 router BlackDiamond 8800 series 20 000 recommended maximum number of IS IS Level 2 routes in a Level 2 IS IS router The numbers BlackDiamond 10808 documented are based on 50 IPv4 routes and MSM 1 60 000 50 IPv6 routes MSM 1XL 130 000 BlackDiamond 12800 series MSM 5 30 000 MSM 5R 60 000 MSM 6R 130 000 Summit X450 and X450a 5 000 IS IS IPv4 IPv6 L1 routes in a L1 L2 router BlackDiamond 8800 series 20 000 recommended maximum number of IS IS Level 1 routes in a Level 1 Level2 IS IS router The Ele Piste osos 20 000 numbers documented are based on 50 IPv4 BlackDiamond 12800 series 20 000 routes and 50 IPv6 routes Summit X450 and EE 3 000 Jumbo frames maximum size supported for All platforms 9 216 jumbo frames including the CRC ExtremeXOS 12 1 4 Installation and Release Notes Metric Product Limit Load sharing groups maximum number of load BlackDiamond 8800 series share
62. 1 IS IS PD3 206929752 Is EAPS with Load Sharing Enabled Disabled Causes Control Packets to be Received on Port Misconfigured EAPS control VLAN ports may not be detected causing EAPS PDUs to be accepted into the system even though they were received on an incorrect port Disabling a Shared Port Makes the ESRP Port Restart Configuration Disappears Disabling a shared port results in the ESRP port restarting and the configuration disappearing MTU Size for a VLAN is Not Configured When issuing the enable jumbo frame port all command on a BlackDiamond 8800 the MTU size for the VLAN is not configured Sending 5 000 byte traffic works correctly However if you disable jumbo frames on the egress port the error message Packet too big is displayed Info Level Messages in Log When Configuring Link Aggregation on VLAN Associated with IPv6 Tunnel The following info level messages appear in the log when link aggregation is configured on a VLAN associated with an IPv6 6 to 4 tunnel 05 01 49 04 lt Info HAL VLAN Info gt MSM B pibIPv6InstallTunneledLinkLocalFilter Could not install filter unit 12 Entry exists 04 24 2007 05 01 49 05 lt Info HAL VLAN Info gt MSM B pibIPv6InstallTunneledLinkLocalFilter Repaired filter unit 12 These messages do not affect the operation of the switch IS IS Graceful Restart Fails With Cisco Neighbor The ExtremeXOS implementation of IS IS supports draft ietf isis restart O2 As
63. 12 0 1 11 SR 12 0 1 11 LX4 12 0 1 11 ZR 12 0 1 11 LW 12 0 1 11 XENPAK modules supported on the Summit X450 switch with ExtremeXOS 12 1 and the minimum ExtremeXOS version required include Table 22 Summit X450 Switch XENPAK Support XENPAK Module ExtremeXOS Required SR EES LR ESAE ER HESTES LX4 METES ZR MESHES ExtremeXOS 12 1 4 Installation and Release Notes XENPAK modules supported on the Summit X450a switch with ExtremeXOS 12 1 and the minimum ExtremeXOS version required include Table 23 Summit X450a Switch XENPAK Support XENPAK Module ExtremeXOS Required SR 11 6 1 9 LR 11 6 1 9 ER 11 6 1 9 LX4 11 6 1 9 ZR 11 6 1 9 LW 11 6 1 9 CX4 12 0 1 11 XENPAK modules supported on the Summit X450e switch with ExtremeXOS 12 1 and the minimum ExtremeXOS version required include Table 24 Summit X450e Switch XENPAK Support XENPAK Module ExtremeXOS Required SR 11 5 1 4 LR 11 5 1 4 ER 11 5 1 4 LX4 11 5 1 4 ZR 11 5 1 4 CX4 MOTIN XENPAK modules supported on the Summit X350 switch with ExtremeXOS 12 1 and the minimum ExtremeXOS version required include Table 25 Summit X350 Switch XENPAK Support XENPAK Module ExtremeXOS Required SR 12 0 3 16 LR 12 0 3 16 ER 12 0 3 16 LX4 12 0 3 16 ZR ZORS RUG XENPAKs not supplied by Extreme Networks will show up as Unsupported Optic Modu
64. 12Protos 0x0 vpif 1 4 on pv50 ingress 0x5 egress 0x1 dereg 0 0 of 50 s PD3 86015166 PD3 96983520 When LACP is enabled on a link between two switches when disabling port sharing the following warning is displayed in the log for each of the protected VLANs 08 02 2006 12 20 31 36 lt Warn EAPS SharedPort SegPortWarning gt EAPS Shared port 4 Segment port 4 No vPif for vlan pv24 Changing the EAPS shared port link ID of a partner controller pair while there is a failure in the EAPS network is not recommended and may cause a loop in the network PD3 131018386 After changing the root blocker and partner IDs the displayed root blocker ID toggles between the original and the changed IDs PD3 135517703 PD3 87003427 PD3 78960443 PD3 78302829 IP Unicast PD3 192315271 PD3 182815070 MPLS PD3 167174547 Configurations having three shared links where the shared link with the lowest ID is in the middle the root blocker marks the segment as blocking down but the ports are not in a blocked state To get out of the loop restore the shared links To avoid encountering this condition insure that no more than two shared links become disabled When a switch is configured for proxy ARP with the always keyword the switch will not respond to a gratuitous ARP request it will only respond to ARP requests The command output for the show vpls peer detail command does not show the peer flags PD3 114261166
65. 177 Resolved Issues in ExtremeXOS 12 1 1 4 0 ccc cece eee e eae e eae e eae nena a eee ease ee saa essa esaeesaeesaeesaaesaaes 180 Resolved Issues in ExtremeXOS 12 1 0 29 0 cceecce cece cece eee e eee erence eee eeeeeeseeesaeesaeeeaeesaeeeaeeaaes 183 ExtremeXOS 12 1 4 Installation and Release Notes Overview These Release Notes document ExtremeXOS 12 1 4 patch1 9 This chapter contains the following sections Configuration Change in ExtremeXOS 12 1 on page 5 Feature Enhancements in ExtremeXOS 12 1 3 on page 5 BGP Enhancements on page 5 Flow Control Summit Family of Switches and BlackDiamond 8800 Series Switches Only on page 32 STP and Network Login on page 45 Health Check Link Aggregation on page 47 New FEFI CLI Command on page 64 New Features or Feature Enhancements in ExtremeXOS 12 1 2 17 on page 66 New Features in ExtremeXOS 12 1 on page 67 New Hardware Supported in ExtremeXOS 12 1 1 4 on page 69 Supported Hardware on page 69 Summit X150 and X350 Series Switch Software Details on page 80 Tested Third Party Products on page 94 Extreme Switch Security Assessment on page 95 Configuration Change in ExtremeXOS 12 1 While loading a configuration from a pre ExtremeXOS 12 1 release and having an ip mtu greater than 9 194 the value is reduced to 9 194 after upgrading to ExtremeXOS 12 1 or later You will not receive a log message notification of this value reduction Feature Enhancements in ExtremeX0S 12 1 3 Fo
66. 2165 forwarded incorrectly SummitStack PD4 547591482 Performing an snmpwalk on OID 1 3 6 1 4 1 1916 1 4 enterprises extremeAgent extremePort on a stack returns the error No Such Object available on this agent Network Login PD4 823485808 Limit learning does not show the blackhole entries if network login is enabled on the same port PD4 765586466 Network login enabled ports are authenticating the switch MAC address in certain loopback configurations Resolved Issues in ExtremeXOS 12 1 3 patch1 6 The following issues were resolved in ExtremeXOS 12 1 3 patch1 6 The numbers shown in column one of the following table are for internal reference and can be ignored ExtremeXOS 12 1 includes all fixes up to and including ExtremeXOS 11 1 4 4 ExtremeXOS 11 2 3 3 ExtremeXOS 11 3 4 5 ExtremeXOS 11 4 4 7 ExtremeXOS 11 5 2 10 ExtremeXOS 11 6 5 3 and ExtremeXOS 12 0 5 For information on those fixes see the release notes for the specific release Table 46 Platform Specific and Feature PDs PD Number General PD4 500100211 Description The vi process may crash when performing a cut copy paste of text that is larger than 10 492 bytes PD4 717931715 After upgrading a PoE capable ExtremeXOS switch from software version ExtremeXOS 11 6 to 12 1 the show configuration poe command is not available PD4 748079627 The debug log lt Info thttpd info gt 13 line feeds removed is not necessary and is shown when config
67. 2804 with the BootROM and firmware images included in this release of ExtremeXOS ExtremeXOS 12 1 4 Installation and Release Notes This release of ExtremeXOS contains the following versions of the BootROM and firmware MSM Bootloader 1 0 0 3 First available in ExtremeXOS 11 4 1 4 PSU controller firmware 2 13 First available in ExtremeXOS 11 4 1 4 Use the show version command to display the versions of the BootROM and firmware currently installed dd NOTE For single MSM systems reboot the switch using the reboot command after the firmware installation is complete To install the new BootROM and firmware wait until the show slot command indicates the MSMs and I O modules are operational Then use the install firmware command This command will install the BootROMs and or firmware only on modules that have older BootROMs or firmware installed Once this installation is complete reboot the switch using the reboot command dd note For dual MSM systems the install firmware command cannot install all the necessary software while the MSM is primary To completely install the firmware an MSM failover is required First run the install firmware command on the primary MSM When the installation is complete run the run msm failover command to allow the switch to failover to the secondary MSM Run the install firmware command on the new primary MSM To revert back to your original primary MSM run the run msm failover command Becaus
68. 29 seconds ExtremeXOS 12 1 4 Installation and Release Notes Slot MSM A Current State MASTER Image Selected secondary Image Booted secondary Primary ver 1200 13 Secondary ver 121 2 Config Selected NONE Config Booted Factory Default Upgrading a BlackDiamond Series of Switches Using Hitless Upgrade dd NOTE You must be running ExtremeXOS 11 1 1 9 or later to use hitless upgrade on a BlackDiamond 10808 switch a gt NOTE For the BlackDiamond 8800 series of switches a hitless upgrade to ExtremeXOS 12 1 1 from an earlier release is not supported Use the normal software upgrade process for these switches Upgrading the Alternate Partition Using Hitless Upgrade Performing a hitless upgrade on the alternate partition allows you to revert to the previous image in case the upgrade is not successful Upgrade the alternate partition using hitless upgrade as follows 1 Run the show switch command to determine which partition is the active partition and which partition is the alternate partition 2 In the following example the secondary image is the active partition The download is performed on the primary image Execute the CLI command download image 10 201 14 13 bd12k 12 1 4 xos primary BD 12804 8 download image 10 201 13 14 bd12k 12 1 4 xos primary Do you want to install image after downloading y yes n no lt cr gt cancel Yes 3 When the download is complete run the show switch command to confi
69. 3 mini GBIC Module G20X 804407 00 904020 10 BlackDiamond 10808 20 port 1OOOBASE X SFP i213 after Rev 03 mini GBIC Module 804470 00 904020 00 11 BlackDiamond 10808 20 port 1OOOBASE X SFP i213 after Rev 08 mini GBIC Module 10G38 804410 00 904032 10 BlackDiamond 10808 2 port 1OGBASE X XENPAK WRES after Rev 03 Module 804471 00 904032 00 11 BlackDiamond 10808 2 port 10GBASE X XENPAK 21 8 after Rev 11 Module 10G2H 804406 00 904027 00 11 BlackDiamond 10808 Hybrid Module 2 port LZA after Rev 09 10GBASE X XENPAK 20 port 1000BASE X SFP 20 port 10 100 1000BASE T RJ 45 804411 00 904027 10 BlackDiamond 10808 Hybrid Module 2 port LL 21 3 after Rev 03 10GBASE X XENPAK 20 port 1OOOBASE X SFP 20 port 10 100 1000BASE T RJ 45 10G6X 804405 00 904016 00 11 BlackDiamond 10808 6 port 1OGBASE X XENPAK LL 2 1 3 after Rev 18 Module 804409 00 904016 10 BlackDiamond 10808 6 port 1OGBASE X XENPAK Li 2 1 3 after Rev 03 Module ExtremeXOS 12 1 4 Installation and Release Notes BlackDiamond 8800 Series of Switches Component Support BlackDiamond 8800 and BlackDiamond 8806 components supported with ExtremeXOS 12 1 and the minimum BootROM version required by the chassis to support each component include Table 3 BlackDiamond 8800 Series of Switches Component Support BlackDiamond 8810 and ExtremeX0S BlackDiamond 8806 Components E
70. 41418181 Using MAC based network login the MAC address is authenticated on the first VLAN only The same MAC address stays in the unauthenticated state in all other subsequent VLANs PD4 476352155 The error message that is logged when adding a port as untagged in more than one VLAN is more user friendly Resolved Issues in ExtremeXOS 12 1 2 17 patch1 4 The following issues were resolved in ExtremeXOS 12 1 2 17 patch1 4 The numbers shown in column one of the following table are for internal reference and can be ignored ExtremeXOS 12 1 includes all fixes up to and including ExtremeXOS 11 1 4 4 ExtremeXOS 11 2 3 3 ExtremeXOS 11 3 4 5 ExtremeXOS 11 4 4 7 ExtremeXOS 11 5 2 10 ExtremeXOS 11 6 4 11 through patch1 8 and ExtremeXOS 12 0 3 16 through patch1 13 For information on those fixes see the release notes for the specific release Table 55 Platform Specific and Feature PDs PD Number General PD4 419725145 PD4 459489323 Description A Summit X250e 48t stack generates the following error message each time a user is authenticated through MAC based network login from the backup switch in the stack Unable to get vpif information IPmc add port PD4 459420351 PD4 337044674 A defective Power over Ethernet PoE module may cause a switch to continuously reboot PD4 463217627 PD4 463217728 Hardware Abstraction Layer HAL memory shows a significant increase when refreshing a policy PD4 359462827
71. 4546 vMAN egress ACL with Class of Service C COS in match condition is resulting in unexpected behavior SNMP PD4 481623940 Simple Network Management Protocol SNMP authentication failure traps do not include IP address details that is the IP address from which the authentication attempt was made ExtremeXOS 12 1 4 Installation and Release Notes Resolved Issues in ExtremeXOS 12 1 2 17 patch1 10 The following issues were resolved in ExtremeXOS 12 1 2 17 patch1 10 The numbers shown in column one of the following table are for internal reference and can be ignored ExtremeXOS 12 1 includes all fixes up to and including ExtremeXOS 11 1 4 4 ExtremeXOS 11 2 3 3 ExtremeXOS 11 3 4 5 ExtremeXOS 11 4 4 7 ExtremeXOS 11 5 2 10 ExtremeXOS 11 6 4 11 through patch1 8 and ExtremeXOS 12 0 3 16 through patch1 13 For information on those fixes see the release notes for the specific release Table 53 Platform Specific and Feature PDs PD Number General PD4 443273921 PD4 438482687 Description When Protocol Independent Multicast PIM receives a prune from a downstream neighbor the prune hold time is not considered This is the time for which the upstream neighbor should hold the prune PD4 443273938 PD4 438482713 PD4 443273984 PD4 438482720 When creating a S G entry from a G entry start the entry timer based on the G egress hold time When a G entry is removed the hold timer should be resta
72. 51784861 10G4Ca modules on BlackDiamond 8800 platforms may require custom pre emphasis settings on an interface by interface basis as some vendor cables and end devices require custom settings to operate without CRC errors Summit Family of Switches PD4 890754513 The error message Operation attempted to set two rules of identical conditions with the same precedence is seen when applying two different policies to two different VLANs PD3 179276997 ACL PD3 28320337 Running the show ports information and show ports configuration commands on a Summit switch that does not include an XGM2 option card erroneously displays the ports on the card as available and enabled MAC and IP MAC entries are being allowed in the same IPv6 ACL rule entry L2 and L3 L4 rules should not be allowed in one entry this should fail the grammar check but does not PD3 55929951 PD3 41829516 The keyword icmp type timestamp when used in an ACL policy match condition does not work Using the ICMP number code instead of the keyword works correctly icmp type 13 PD3 28320337 MAC and IP MAC entries are being allowed in the same IPv6 ACL rule entry L2 and L3 L4 rules should not be allowed in one entry this should fail the grammar check but does not PD3 42872248 bea Creating dynamic ACLs using the operands lt or lt results in an error Use It and Ite instead PD3 42447111 PD3 166801770 The ACL
73. 6 can be selected links and the remaining 16 will be standby links e A Health Check LAG can include a maximum of 16 ports e The maximum number of LAGs is 128 On the BlackDiamond 10808 12800 and 20808 series switches if you do not explicitly select an algorithm the port based scheme is used However the address based algorithm has a more even distribution and is the recommended choice oO dd note You must use the configure sharing address based command to configure address based load sharing on the BlackDiamond 10808 and 12800 series switches Example The following example defines a static link aggregation group LAG on a modular switch that contains ports 9 through 12 on slot 3 ports 7 through 10 on slot 5 and uses the first port on slot 3 as the logical port 9 on a modular switch enable sharing 3 9 grouping 3 9 3 12 5 7 5 10 In this example logical port 3 9 represents physical ports 3 9 through 3 12 and 5 7 through 5 10 The following example defines a dynamic LAG on a stand alone switch containing ports 10 through 15 with port 10 being the logical port enable sharing 10 grouping 10 15 lacp The following example defines a health check LAG containing ports 10 through 13 with port 10 as the master logical port and specifies address based link aggregation by Layer 3 IP plus Layer 4 port enable sharing 10 grouping 10 11 12 13 algorithm address L3_L4 health check To configure a health check LAG refer to the config
74. 68 add track tcp 192 168 add track tcp 192 168 add track tcp 192 168 101 tcp port 8080 102 tcp port 8080 103 tcp port 8080 104 tcp port 8080 ouou PRPRPPR Displaying Health Check Link Aggregation To display information for a health check LAG use the following command show sharing health check Health Check Link Aggregation Commands Following are CLI commands for Health Check Link Aggregation ExtremeXOS 12 1 4 Installation and Release Notes configure sharing add ports configure sharing lt port gt add ports lt port_list gt Description Adds ports to a load sharing or link aggregation group By using link aggregation you use multiple ports as a single logical port Link aggregation also provides redundancy because traffic is redistributed to the remaining ports in the link aggregation group LAG if one port in the group goes down Syntax Description port Specifies the logical port for a load sharing group or link aggregation group LAG This number also functions as the LAG Group ID port_list Specifies one or more ports or slots and ports to be grouped in the LAG Default N A Usage Guidelines dd note You must create a LAG or load sharing group before you can configure the LAG To create a LAG see enable sharing lt port gt grouping lt port_list gt algorithm port based address based L2 L3 L3_L4 lacp health check Use this command to dynamically add ports to a lo
75. 8 Switch Component Support BlackDiamond 10808 components supported with ExtremeXOS 12 1 and the minimum ExtremeXOS version required by the chassis to support each component include ExtremeXOS 12 1 4 Installation and Release Notes Table 1 BlackDiamond 10808 Component Support ExtremeX0S BootROM Version BlackDiamond Component ExtremeXOS Filenames Required MSM 1 bd10k 12 1 4 2 patch1 8 xos MSM 1XL bd10k 12 1 4 2 patch1 8 xos 10 1 0 OnES 10G38 N A 11 1 1 1 3 0 0 10G2H N A 11 2 0 1 3 0 0 10G6X N A 10 1 0 131010 G20X N A ilI 1 3 0 0 G60X N A 10 1 0 1 3 0 0 G60T N A 10 1 0 1 3 0 0 PSU Controller N A 10 1 0 N A 700 1200 W AC PSU Model N A 10 1 0 N A 60020 PS 2336 1200 W DC PSU Model N A 1073126 N A 60021 PS 2350 Following are the part numbers for the BlackDiamond 10808 modules with the Rev D ASIC Table 2 BlackDiamond 10808 1 0 Modules with Part Numbers 1 0 8000 Level 9000 Level Part ExtremeX0S Module Part No No Description Required G60T 804403 00 904015 00 BlackDiamond 10808 60 port 10 100 1O000BASE T 11 2 1 3 after Rev 16 RJ 45 Module 804408 00 904015 10 BlackDiamond 10808 60 port 10 100 1O000BASE T 11 2 1 3 after Rev 03 RJ 45 Module G60X 804402 00 904009 00 11 BlackDiamond 10808 60 port 1OOOBASE X SFP i213 after Rev 16 mini GBIC Module 804404 00 904009 10 BlackDiamond 10808 60 port 1OOOBASE X SFP i213 after Rev 0
76. 800 Series Switches Only 802 10 tags of valid VLANs configured on a switch can exist as arguments to the vlan id keyword in an ACL rule If a VLAN is deleted from the switch the corresponding VLAN ID needs to be removed from all policy files Removed the following deprecated VMAN action modifiers from the ExtremeXOS Concepts Guide Software Version 12 1 2 vMANs and Tunneling E stag ethertype E lag aggregation hash Added the following SNMP commands See the ExtremeXOS Command Reference Software Version 12 1 2 Managing the Switch E enable snmp community E disable snmp community New Hardware Supported in ExtremeXOS 12 1 2 17 The following modules are supported in ExtremeXOS 12 1 2 17 XFP modules m ZR XFP m DWDM XFP Supported on the Summit XGM2 2xf option card in the Summit X450a X450e and X350 series switches also on the 10G4Xa 10G4Xc and 10G8Xc modules in the BlackDiamond 8800 series switches ExtremeXOS 12 1 4 Installation and Release Notes New Features in ExtremeXOS 12 1 Following are the new features supported in ExtremeXOS 12 1 These features will be documented in detail in the ExtremeXOS 12 1 versions of the ExtremeXOS Concepts Guide or the ExtremeXOS Command Reference Guide unless otherwise noted e The show configuration command now displays configuration changes made by a user to factory default settings e ScreenPlay now supports a Dynamic ACL Editor and CLI shell To use the CLI Sh
77. AK modules is available only on the BlackDiamond 10808 switch BlackDiamond 12800 series switches BlackDiamond 20808 series switches and the Summit X450a and X650 series switches whether or not included in a SummitStack ExtremeXOS 12 1 4 Installation and Release Notes STP and Network Login Spanning Tree Protocol STP and Network Login work on the edge port with safeguard only If a port has netlogin enabled but does not have STP safeguard enabled the STP domain cannot be enabled This feature works with spanning tree operational mode dotlw and MSTP Limitation This feature does not support network login in Campus mode STP works in three port modes e Extreme Multiple Instance Spanning Tree Protocol EMISTP mode EMISTP mode is proprietary to Extreme Networks and is an extension of STP that allows a physical port to belong to multiple STPDs by assigning the port to multiple VLANs EMISTP adds significant flexibility to STP network design BPDUs are sent with an 802 1Q tag having an STPD instance Identifier StpdID in the VLANid field This encapsulation mode supports the following STPD modes of operation 802 1D and 802 1w e Per VLAN Spanning Tree PVST mode This mode implements PVST in compatibility with third party switches running this version of STP The STPDs running in this mode have a one to one relationship with VLANs and send and process packets in PVST format This encapsulation mode supports the following STPD
78. AN name download Download system image bootrom BootROM image Image ssl SSL edit Edit file policy Policy script ExtremeXOS CLI script enable Enable running system setting access list Access list bootp Configure BOOTP client bootprelay Enable BOOTP relay service cli CLI settings cli config logging CLI command logging clipaging Display command output one screen at a time cpu monitoring Monitor system process CPU utilization dhcp Configure DHCP client diffserv Diffserv dos protect Automatic denial of service protection dotlp Dotlp eaps EAPS Ethernet Automatic Protection Switching domain edp EDP elrp client ELRP Extreme Loop Recovery Protocol Client elsm ELSM Extreme Link Status Monitoring esrp designated carrier ESRP designated carrier feature flooding Flooding icmp ICMP option idletimeout Timeout for idling configuration session igmp IGMP protocol inline power Inline power ip option IP option ip security IP security ExtremeXOS 12 1 4 Installation and Release Notes Table 29 Summit X150 and X350 Supported Commands Continued Command Description iparp IP ARP command iproute IPROUTE help jumbo frame Jumbo frame learning Learning license ExtremeXOS license or feature pack IIdp Configure LLDP specific settings log Configure log service loopback mode Loopback mac lockdown timeout MAC lockdown timeout mirroring M
79. ASE T SFP 11 1 1 9 SX SFP i aS LX SFP 11 1 1 9 ZX SFP 11 1 1 9 100FX 1000LX SFP ULSS 100FX SFP 11 4 3 4 or 11 5 2 10 not supported in 11 5 1 4 1000BX SFP 11 4 1 4 LX100 SFP 12 0 1 11 10 100 1000BASE T Copper SFP 12 0 2 25 SFPs supported on the BlackDiamond 10808 switch with ExtremeXOS 12 1 and the minimum ExtremeXOS version required include Table 9 BlackDiamond 10808 Switch SFP Support SFP ExtremeXOS Required LX100 SFP 12 0 1 11 Se TAAS SEY LX SFP 10 1 0 ZX SFP 10 1 0 1000BASE T SFP LLLE 1000BX SFP 11 6 1 9 SFPs supported on the BlackDiamond 12804 switch with ExtremeXOS 12 1 and the minimum ExtremeXOS version required include Table 10 BlackDiamond 12804 Switch SFP Support SFP ExtremeX0S Required SX SFP 11 4 1 4 LX SFP 11 4 1 4 ZX SFP 11 4 1 4 1OOOBASE T SFP 11 4 1 4 ExtremeXOS 12 1 4 Installation and Release Notes Table 10 BlackDiamond 12804 Switch SFP Support SFP ExtremeXOS Required 1000BX SFP 11 6 1 9 LX100 SFP 12 0 1 11 100FX 1000LX SFP 11 6 1 9 SFPs supported on the BlackDiamond 12802 switch with ExtremeXOS 12 1 and the minimum ExtremeXOS version required include Table 11 BlackDiamond 12802 Switch SFP Support SFP ExtremeXOS Required SX SFP 12 0 1 11 LX SFP 12 0 1 11 DS Srl 12 0 1 11 1OOOBASE T SFP 12 0 1 11 1000BX SFP 12 0 1 11 LX100 SFP 12 0 1 11 100FX 1000LX SFP 12 0 1 11 SFPs suppo
80. Appendix A ExtremeXOS Software Licenses ExtremeXOS 12 1 4 Installation and Release Notes disable bgp peer group originate default disable bgp peer group lt peer group name gt address family ipv4 unicast ipv4 multicast originate default Description Removes default routes to all BGP neighbors in the specified peer group Syntax Description peer group lt peer group name gt Specifies the BGP peer group for which the default routes are removed ipv4 unicast Specifies that the default routes apply to IPv4 unicast routes If you do not specify an address family the command applies to IPv4 unicast routes ipv4 multicast Specifies that the default routes apply to IPv4 multicast routes Default Disabled BGP does not automatically originate and advertise default routes to BGP neighbors Usage Guidelines This command can be successfully executed at any time irrespective of whether local BGP or the remote BGP peers are enabled or disabled Example The following command removes default routes for IPv4 unicast traffic for all nodes in the test BGP peer group disable bgp peer group test originate default History This command was first available in ExtremeXOS 12 1 3 Platform Availability This command is available on platforms with the appropriate license For complete information about software licensing including how to obtain and upgrade your license and what licenses are appropriate for this feat
81. Automatic Protection Switching elrp ELRP Extreme Loop Recovery Protocol elsm ELSM Extreme Link Status Monitoring esrp ESRP Extreme Standby Router Protocol fdb FDB igmp IGMP protocol inline power Inline power ip security IP security iparp IP ARP command ipmc IP multicast help I2stats Layer 2 stats lacp LACP Link Aggregation Control Protocol license info License information in EEPROM log Clear log message for memory target mid MLDP Multicast Listener Discovery Protocol neighbor discovery IPv6 neighbor netlogin ExtremeXOS 12 1 4 Installation and Release Notes Show network login specific information Table 29 Summit X150 and X350 Supported Commands Continued session Command Description Session sys recovery level Clear persistent sys recovery level vlan VLAN lt esrpDomain gt ESRP domain name lt vlan_name gt VLAN name configure Configure running system information access list Access list account Login account banner System login banner bootprelay Configure BOOTP relay service cli CLI cpu transmit priority CPU transmit priority debug Debug information core files diffserv Diffserv dns client DNS Client dos protect Automatic denial of service protection dotlp Dotlp eaps EAPS Ethernet Automatic Protection Switching edp EDP egress Egress elrp client ELRP Extreme Loop Recovery Protocol client elsm ELSM Extreme Li
82. CntSmplFail gt Previous message repeated 61 additional times in the last 1200 second s Redundant Ports Not Correctly Moving to Other Ports in Load Sharing Mode Traffic on load share ports configured as redundant ports incorrectly moves to other ports in the load share group during link transition Link State May Not be Correct on a Redundant Port After running the disable port all command on a switch that is configured with a redundant port the link state may not always be correct PD3 209191768 Some Port LEDs May Light Green Even Though Ports are Not Up After running the disable port all command on a SummitStack some port LEDs may sometimes light green even though ports are not up PD3 204744742 ACL PD3 192175421 Ping in VR Mgmt in SummitStack Displays Node Address Instead of MAC Address IPv6 neighbor discovery in a management VLAN in a SummitStack resolves to the node address of the stack master instead of the stack MAC address Installing a Policy File May Generate an Error Message The following error message is displayed when installing a policy file with more than 4 096 rules Error Unable to bind traffic queue tq4095 to port 1 1 PD3 127190211 VLAN ACLs Do Not Work When vMAN Ethertype is Set to 0x8100 Using a BlackDiamond 10808 or a 12800 series switch VLAN ACLs do not work when a vMAN EtherType is set to Ox8100 Incoming traffic is not matched against the rules in the ACL policy file and t
83. Cs are inserted in a Summit X450 and some of the links are between a BlackDiamond 8800 and the Summit X450 if the 1OOFX is disabled and rebooted multiple ports of the Summit X450 no longer display in the show ports configuration command output When downgrading a switch from ExtremeXOS 12 1 to an earlier version of ExtremeXOS software it is recommended that you disable the unicast and multicast capabilities of BGP after the downgrade When DHCP snooping is enabled bursts of DHCP traffic may cause exceptions system crash in the DHCP snoop module System health check related configurations are not stored in uploaded configurations ExtremeXOS 12 1 4 Installation and Release Notes Table 57 Platform Specific and Feature PDs Continued EAPS PD3 203480721 When a BlackDiamond 10808 or BlackDiamond 12800 series switch is configured as an EAPS controller in a scaled environment consisting of 130 or more EAPS domains 4 000 protected VLANs and 200 000 or more FDB entries the failure or restoration of the EAPS common link may cause a short network loop PD3 202013003 IS IS PD3 194507463 MAC in MAC PD3 189838058 MPLS PD3 209423226 When an EAPS shared port controller or partner switch reboot when the shared port LACP is active but the shared port status is still blocking a temporary loop and broadcast storm occurs Multiple L1 L2 routers in the same L1 area with at least one non overlapping area address incor
84. E TEES EE EEEn RESON 134 Known Behaviors icasvusien casavethvcneh lt deaevaavstixqcs eE EEE EEEE AEON Ea AEEA EANES E S PEA nA ENTE EAEG A ESA 148 Resolved Issues in ExtremeXOS 12 1 4 patch1l 9 ssussssnsrsrsersssrrsrssrsrrrnrsrrrrerrrrrrerrrrererrsreresre 153 Resolved Issues in ExtremeXOS 12 1 4 patch 1 8 ccccccccccccce ees eecece eee eeseseeeeeeeeeeeeeaeeeeeaeeaeeeaes 153 Resolved Issues in ExtremeXOS 12 1 4 patch 1 7 cccccccccccccccceccee cece eeeeeeceeeeeeeeseeeseeeseeeeeeeeeeeennes 154 Resolved Issues in ExtremeXOS 12 1 4 patch 1 6 cccccccccccccaceceececeeeeeeeseeeeeeeeeeeeeseseeeeeaseaeeges 154 Resolved Issues in ExtremeXOS 12 1 4 patch 1 5 eccccccceccee cece eeeee esse eee eeseeeseeeseeeeaeeseeeenaes 155 Resolved Issues in ExtremeXOS 12 1 4 patch 1 4 ccc ccccceccee cece eeeeeecee eee eeseeeseeeseeesaeeeeeeenaes 155 Resolved Issues in ExtremeXOS 12 1 4 patch1 3 0 ccccccccccccceeceeceeeeeeeeeeeeeeeeeeeeseesaeeeeeaeeaeeeges 156 Resolved Issues in ExtremeXOS 12 1 4 patch 1 20 ecccccccccccaceceeceeee een eeeeseeeeeeeeeeeeeeeeseeaeeaeeeaes 156 Resolved Issues in ExtremeXOS 12 1 4 patch 1 1 oo ccc ccccceccce cece eeeeeeee esse eeseeeseeeseeeseeeeeeeenaes 157 Resolved Issues in ExtremeXOS 12 1 4 cceecccceececseceeeeeeeeseeeeeseeeeeseeeesseeeeseneeeseeeesaeeeeaseeeaeeeees 158 Resolved Issues in ExtremeXOS 12 1 3 patch 1 900 eccceccceccee cece cece ecee esse eeseeeseeeseeeeeeeeaeeenees 159 Resolved Issues in ExtremeXOS 12 1 3 pa
85. EAPS Ethernet Automatic Protection Switching domain esrp ESRP Extreme Standby Router Protocol domain fdbentry FDB entry log Configure log service meter Ingress traffic metering netlogin Netlogin protocol Protocol qosprofile QoS profile stpd STP domain tunnel Tunnel vlan VLAN configuration vman vMAN configuration lt eapsDomain gt EAPS domain name lt metername gt Meter name lt stpd_name gt STP domain name lt tunnel_name gt Tunnel name lt vlan name gt VLAN name disable Disable running system setting access list Access list bootp Configure BOOTP client bootprelay Enable BOOTP relay service cli CLI settings cli config logging CLI command logging clipaging cpu monitoring Display command output one screen at a time Monitor system process CPU utilization ExtremeXOS 12 1 4 Installation and Release Notes Table 29 Summit X150 and X350 Supported Commands Continued Command Description dhcp Configure DHCP client diffserv Diffserv dos protect Automatic denial of service protection dotlp Dotlp eaps EAPS Ethernet Automatic Protection Switching domain edp EDP elrp client ELRP Extreme Loop Recovery Protocol Client elsm ELSM Extreme Link Status Monitoring flooding Flooding icmp ICMP option idletimeout Timeout for idling configuration session igmp IGMP Protocol inline power Inline Power ip option IP option
86. Error in alloc txmi txmi 0x9f4 txmdi Oxffffffff Error in alloc txmi txmi 0x1102 txmdi Oxfffffffft Error in alloc txmi txmi 0x9f6 txmdi Oxffffffff Error in alloc txmi txmi 0x9f8 txmdi Oxffffffff PD3 62778911 Converging MVR with EAPS on a BlackDiamond 8800 Causes a Large Packet Loss With MVR enabled on a BlackDiamond 8800 when the ingress port is on the egress list this causes a high volume of traffic loss PD3 64743301 OSPF PD4 299382986 PD4 217017923 Configuring a Meter Value Not Working Properly on a BlackDiamond 12804 When configuring a meter value using a large number for example 10 000 Gbps on a BlackDiamond 12804 switch the CLI accepts the command However when you run the show meter command an incorrect value is displayed Actual Inter Area Route is Also Shown in Summary Route When running the show iproute command the actual inter area route is also shown in the summary route with a virtual link in the command output PD3 133427241 QoS PD4 259174051 OSPF Filter Not Filtering All Routes When an OSPF external filter is configured to deny routes not all routes are being filtered Denial of Service Protection Statistics Are Not Cleared The clear counters command does not clear dos protect statistics PD3 202190332 HQoS Allows Multiple Egress Queues to be Linked to a Single Ingress allow egress Queue Configuring HQoS allows multiple egress queues to be linked to a single
87. ExtremeXOS 12 1 includes all fixes up to and including ExtremeXOS 11 1 4 4 ExtremeXOS 11 2 3 3 ExtremeXOS 11 3 4 5 ExtremeXOS 11 4 4 7 ExtremeXOS 11 5 2 10 ExtremeXOS 11 6 5 3 and ExtremeXOS 12 0 5 For information on those fixes see the release notes for the specific release Table 44 Platform Specific and Feature PDs PD Number Description General PD4 740925847 The following error message is displayed in the log when adding ports to an ESRP slave VLAN lt Crit vlan err criticalInfo gt MSM A Critical Info sysctlWriteSetting cannot open file PD4 507170288 Traffic received on an STP EAPS blocked port is being sent to the CPU if the source MAC address of the incoming packet matches the MAC address of the DUT system BlackDiamond 8800 Series Switch PD4 791316018 When using SCP to download an image the image fails to install on the backup MSM and the following error is displayed Installing to MSM BError Failed to install image tar scratch bd8800 12 1 3 14 xos No such file or directory Summit Family Switches PD4 814229965 Multicast packets using a system MAC address as a destination MAC address are perodically leaked in slowpath every 30 seconds PD4 798967898 A Summit X450 switch shows an error when trying to apply a dynamic ACL using the meter action modifier ACL PD4 809832196 The output for the show configuration acl command contains the wrong syntax for meter configuration if the create met
88. ExtremeXOS Installation and Release Notes Software Version ExtremeXOS 12 1 4 patch1 9 Extreme Networks Inc 3585 Monroe Street Santa Clara California 95051 888 257 3000 408 579 2800 http www extremenetworks com Published August 2010 Part Number 120415 00 Rev 45 AccessAdapt Alpine Altitude BlackDiamond EPICenter ExtremeWorks Essentials Ethernet Everywhere Extreme Enabled Extreme Ethernet Everywhere Extreme Networks Extreme Standby Router Protocol Extreme Turbodrive Extreme Velocity ExtremeWare ExtremeWorks ExtremeXOS Go Purple Extreme Solution ExtremeXOS ScreenPlay ReachNxT Sentriant ServiceWatch Summit SummitStack Triumph Unified Access Architecture Unified Access RF Manager UniStack the Extreme Networks logo the Alpine logo the BlackDiamond logo the Extreme Turbodrive logo the Summit logos and the Powered by ExtremeXOS logo are trademarks or registered trademarks of Extreme Networks Inc or its subsidiaries in the United States and or other countries sFlow is a registered trademark of InMon Corporation Specifications are subject to change without notice All other registered trademarks trademarks and service marks are property of their respective owners 2010 Extreme Networks Inc All Rights Reserved ExtremeXOS 12 1 4 Installation and Release Notes G Contents HE A A sista secccttsnticadectincncccendetvadecsadstevexsssnescdextueasestataudcanpdbnassavidsticenacacaissnadvcaiienscesn
89. ExtremeXOS software version 11 2 the switch can use IPv6 addresses The maximum number of LAGs is 32 e Broadcast multicast or unknown unicast packets are transmitted differently depending on the device you are using m On the BlackDiamond 8800 original series modules these packets are transmitted on a single port of a LAG m On the BlackDiamond 8000 a series c series and e series modules these packets are distributed across all members of a LAG The distribution of these packets depends on the type of the traffic Broadcast L2 multicast and unknown unicast traffic distribution is based on the source and ExtremeXOS 12 1 4 Installation and Release Notes destination MAC addresses IP multicast traffic distribution is based on the source and destination IP addresses This behavior is not configurable e Beginning with ExtremeXOS version 11 5 the maximum number of LAGs is 128 unless a 10G4X module is in use in the chassis in which case the maximum number of LAGs is 32 dd NOTE You cannot configure more than 32 LAGs on a BlackDiamond 8800 chassis with a 10G4X module running or that has a slot configured for the 10G4X module The following switch configurations support 32 LAGs m A BlackDiamond 8800 switch that contains an 10G4X module or has a slot configured for the 10G4X module m A SummitStack that contains an original Summit X450 switch or has a slot configured for the X450 switch If you attempt to configure mo
90. FGPA firmware to slot 5 This will takes a few minutes Installing microcontroller firmware to slot 6 Installing FGPA firmware to slot 6 This will takes a few minutes To verify that your firmware upgrade on both the MSM and I O modules has been successful verify using the following command show version detail BD 12804 1 show version detail Chassis 804030 00 05 07085 00026 Rev 5 0 Slot 1 804031 00 05 0706F 00200 Rev 5 0 uC 5 00 FPGA 5 0d Slot 2 804031 00 05 0703F 00184 Rev 5 0 uC 5 00 FPGA 5 0d Slot 5 804031 00 05 0703F 00185 Rev 5 0 uC 5 00 FPGA 5 0d Slot 6 MSM A 804046 00 07 0706F 00117 Rev 7 0 BootROM 1 0 0 3 IMG 12 1 3 uC 5 00 FPGA 3 30 MSM B 804046 00 07 0706F 00122 Rev 7 0 BootROM 1 0 0 3 IMG 12 1 4 uC 5 00 PSUCTRL 1 700111 00 01 06525 00997 Rev 1 0 BootROM 2 13 PSUCTRL 2 700111 00 01 06525 00909 Rev 1 0 BootROM 2 13 PSU 1 PS 2336 4300 00145 0641K 22897 Rev 1 0 PSU 2 PS 2336 4300 00145 0641K 23307 Rev 1 0 PSU 3 PS 2336 4300 00145 0641K 23266 Rev 1 0 PSU 4 a PSU 5 PSU 6 Image ExtremeXOS version 12 1 4 v1202b25 by release manager on Tue Nov 6 22 56 10 PST 2007 BootROM 1 0 0 3 BD 12804 2 Following is an example of the old FPGA version MSM 3 2a I O 5 07 or earlier Following is an example of the new FPGA version MSM 3 30 I O 5 0d The backup MSM version is not shown until the MSM is made the primary MSM Upgrading ExtremeXO
91. If the failed port becomes active again traffic is redistributed to include that port Link aggregation must be enabled on both ends of the link or a network loop will result dd note See ExtremeXOS Concepts Guide for information on the interaction of port based ACLs and LAGs of ports Modular switch LAGs are defined according to the following rules e Although you can reference only the logical port of a LAG to a Spanning Tree Domain STPD all the ports of a load sharing group actually belong to the specified STPD e When using link aggregation you should always reference the logical port of the LAG when configuring or viewing VLANs VLANs configured to use other ports in the LAG will have those ports deleted from the VLAN when link aggregation becomes enabled Link aggregation or load sharing algorithms allow you to select the distribution technique used by the LAG to determine the output port selection Algorithm selection is not intended for use in predictive traffic engineering e Port based Uses the ingress port to determine which physical port in the LAG is used to forward traffic out of the switch e Address based Uses addressing information to determine which physical port in the LAG to use for forwarding traffic out of the switch Refer to configure sharing address based for more information on using addressing information Summit X250e X450a X450e and X650 series switches and SummitStack only The followin
92. Ld Share Algorithm The algorithm used for the link aggregation The available link aggregation algorithms vary among platforms see the ExtremeXOS Concepts Guide for more information Ld Share Group The specific ports that belong to each LAG or the port numbers in the trunk A port can belong to only one LAG either static or dynamic Agg Mbr In LACP this shows whether the port has been added to the aggregator or not it will be either Y for yes or for no Link State This is the current status of the link Link Up transitions Number of times the link has cycled through being up then down then up Example The following command displays link aggregation on the switch show ports sharing ExtremeXOS 12 1 4 Installation and Release Notes The following is sample output from this command on a Summit X450 series switch Load Sharing Monitor Config Current Agg Ld Share Ld Share Agg Link Link Up Master Master Control Algorithm Group Mbr State transitions 1 1 hlth chk L2 1 Y A 1 L2 1 A T L2 T Y A I 5 5 LACP L2 5 Y A 3 L2 6 Y A 3 L2 7 Y A 3 L2 8 Y A 3 L2 9 A 3 L2 10 A 3 12 Static L2 12 R 0 L2 13 R 0 Link State A Active D Disabled R Ready NP Port not present L Loopback Load Sharing Algorithm L2 Layer 2 address based L3 Layer 3 address based L3_L4 Layer 3 address and Layer 4 port based Default algorithm L2 Number of load sharing trunks 2 History This command w
93. MAC multicast FDB entries maximum BlackDiamond 8800 original series 256 number of permanent multicast MAC entries Bice Diamond aecureccncs 1 024 configured into the FDB BlackDiamond 8800 a series 1 024 BlackDiamond 8800 e series 1 024 BlackDiamond 10808 1 024 BlackDiamond 12800 series 1 024 Summit X150 and X350 series 1 024 Summit X250e 1 024 Summit X450 original series 256 Summit X450e 1 024 Summit X450a 1 024 Syslog servers maximum number of All platforms 4 simultaneous syslog servers that are supported TCAM entries amount of entries available in BlackDiamond 10808 MSM 1 128 000 the lookup tables for Longest Prefix Match routing lookups learned MAC address and ple ermote Woe WS Hn 256 000 ACLs BlackDiamond 12800 series 49 000 BlackDiamond 12800 R series 229 000 Telnet number of sessions maximum number All platforms 8 of simultaneous Telnet sessions Virtual routers number of user virtual routers that can be created on a switch BlackDiamond 8800 series BlackDiamond 10808 BlackDiamond 12800 series Summit X250e Summit X450 Not supported 8 8 Not supported Not supported VLAN aggregation maximum number of port VLAN combinations on any one super VLAN and all of its sub VLANs All platforms 1 000 VLANs includes all VLANs All platforms 4 094 VLANs maximum number of ports BlackDiamond 12804 50 029 VLANs Layer 2 maximum number of Layer 2 All platforms 4 094 VLANs
94. Network Login maximum number of clients BlackDiamond 8800 series clients per being authenticated on MAC based VLAN module per system 1 024 ele alle poris BlackDiamond 12804 per system 4 000 Summit X250e per system 1 024 Summit X450 per system 1 024 Network Login maximum number of dynamic All platforms 2 000 VLANs OSPF adjacencies maximum number of BlackDiamond 8800 series 128 supported OSPF adjacencies BlackDiamond 10808 255 BlackDiamond 12800 series 255 Summit X250e 128 Summit X450 128 OSPF areas as an ABR how many OSPF areas All platforms 8 are supported within the same switch OSPF ECMP maximum number of equal cost BlackDiamond 8800 series configurable 2 4 or 8 plultipanth CSP BlackDiamond 10808 8 BlackDiamond 12800 series 8 Summit X250e configurable 2 4 or 8 Summit X450 configurable 2 4 or 8 ExtremeXOS 12 1 4 Installation and Release Notes Metric Product Limit OSPF external routes recommended maximum BlackDiamond 8800 series 20 000 ruber eneral routes contained 9a O PF tackDiamond 10808 130 000 routes BlackDiamond 12800 series 130 000 Summit X250e 5 000 Summit X450 5 000 OSPF inter or intra area routes recommended BlackDiamond 8800 series 7 000 a ee Staats eckDiamond 10808 7 000 other types of OSPF routes with one ABR in BlackDiamond 12800 series 7 000 OSPF domain Summit X250 2 000 Summit X450 2 000 OSPF routers in a single area recommended Blac
95. P multicast streams are not egressing the switch resulting in traffic loss After a client is authenticated if the client port is deleted and added back as a tagged port the client is not authenticated for approximately five minutes During this time data traffic from the client is dropped PD4 507339161 If the first dot1x login fails network login remains in an aborted state even after a successful login PD4 640023183 PD4 424705571 A switch may stop responding when running the enable netlogin port 3 4 dot1x command and fail to upload the configuration with the error Operation draining timed out during save Setting g mServer configCurrent to NULL ExtremeXOS 12 1 4 Installation and Release Notes Table 49 Platform Specific and Feature PDs Continued PD4 435524161 Multicast PD4 570383051 PD4 294441183 PD4 633690679 A network login client is not moved to an authentication failure VLAN in specific configurations Some ASCII configuration issues in multicast manager and virtual router modules have been resolved e Default values for IGMP and multicast listener discovery MLD should not be displayed for any user configured virtual routers in the show configuration output e Disable IGMP and MLD should not display the protocol version in the output of the show configuration command e Flow VRs will soon be deprecated so disable flowvsr should not be displayed in the output of the show configura
96. Protocol IGMP snooping as the ages of the incoming streams are reset to O When a network login authentication method is enabled globally enabled netlogin lt dot1x mac web gt on a port for the first time all the FDB entries corresponding to that port are not getting flushed The SNMP Object Identifier OID extremeVlanlfadminstatus used to disable a VLAN in ExtremeXOS returns an error However enabling a VLAN from a disabled state is functioning correctly PD4 360182229 PD4 457325601 The Simple Network Management Protocol SNMP does not respond to an snmpwalk after adding a trapreceiver if a community name starts with a v If the community name begins with a v and has more than one character the switch does not respond However the switch responds if the community name is only v ExtremeXOS 12 1 4 Installation and Release Notes Resolved Issues in ExtremeXOS 12 1 2 17 patch1 3 The following issues were resolved in ExtremeXOS 12 1 2 17 patch1 3 The numbers shown in column one of the following table are for internal reference and can be ignored ExtremeXOS 12 1 includes all fixes up to and including ExtremeXOS 11 1 4 4 ExtremeXOS 11 2 3 3 ExtremeXOS 11 3 4 5 ExtremeXOS 11 4 4 7 ExtremeXOS 11 5 2 10 ExtremeXOS 11 6 4 11 through patch1 8 and ExtremeXOS 12 0 3 16 through patch1 13 For information on those fixes see the release notes for the specific release Table 56 Platform Specific and Feature PDs PD Numbe
97. S 12 1 4 Installation and Release Notes oO dd note The BlackDiamond 10808 12800 and 20808 series switches have an additional flag p Load Sharing Algorithm port based The following command displays detailed port system related information on a BlackDiamond 8810 switch show port 1 1 info detail Following is sample output from this command Port Tet Virtual router VR Default Type UTP Random Early drop Unsupported Admin state Enabled with auto speed sensing auto duplex Link State Ready Link Counter Up 0 time s VLAN cfg Name vl Internal Tag 4093 MAC limit No limit Virtual router VR Default STP cfg Protocol Name v1 Protocol ANY Match all protocols Trunking Load sharing is not enabled EDP Enabled ELSM Disabled Learning Disabled forward packets Unicast Flooding Enabled Multicast Flooding Enabled Broadcast Flooding Enabled Jumbo Disabled Flow Control Tx Pause Enabled Link up down SNMP trap filter setting Enabled Egress Port Rate No limit Broadcast Rate No limit Multicast Rate No limit Unknown Dest Mac Rate No limit QoS Profile None configured Ingress Rate Shaping Unsupported Ingress IPTOS Examination Disabled Ingress 802 1p Examination Enabled Ingress 802 1p Inner Exam Disabled Egress IPTOS Replacement Disabled Egress 802 1p Replacement Disabled NetLogin Disabled NetLogin port mode Port based VLANs Smart redundancy Enabled Softw
98. S on a Summit X150 and X350 Upgrade ExtremeXOS on a Summit X150 and X350 to ExtremeXOS 12 1 4 as follows 1 Save your configuration to a backup configuration file using the save configuration lt configuration_file_name gt command You must save your configuration to a backup configuration file in order to revert to your currently running image if the need arises Run the show version command to verify the BootROM version currently running on your switch ExtremeXOS 12 1 4 Installation and Release Notes If you are not running BootROM version 1 0 3 1 upgrade the BootROM using the following command download bootrom lt tftp server ipaddress gt pmon_summit 1 0 3 1 xtr vr lt vrname gt Determine your current active image partition by running the show switch command The Image Booted field shows the current active partition Download the ExtremeXOS 12 1 4 image to the alternate partition using the following command download image lt ipaddress gt lt filename gt vr lt vrname gt lt image partition gt For example if your current image is running in the primary partition download the new image in the secondary partition download image 10 60 116 11 summitX 12 1 4 xos vr vr mgmt secondary Run the show switch command again to determine that the image is downloaded into the partition you have specified Reboot the switch Use the reboot command to reboot the switch When the switch comes up run the save configuration
99. SA originated by the router having the highest OSPF router ID is used The router having the lower OSPF router ID can then flush its LSA However an ExtremeXOS switch does not purge the functionally equivalent AS external LSA when an Extreme OSPF router ID is lower PD4 701099374 QoS PD4 512656071 ScreenPlay PD4 774800225 Setting the ospfSetTrap OID mib 2 14 16 1 1 0 to OxOOOOffff does not cause OSPF to send out OSPF traps A HAL process crash occurs when HQoS is used with CLEAR Flow and CLEAR Flow rules are enabled ScreenPlay shows the wrong port speed after setting autonegotiation to off and on because the XML API returns the incorrect configuration speed after disabling and enabling autonegotiation PD4 552010000 The following message is periodically logged when the Event Log screen is left open in ScreenPlay Login passed for user admin through xml ExtremeXOS 12 1 4 Installation and Release Notes Table 46 Platform Specific and Feature PDs Continued SNMP PD4 747221911 Changing the storage type of default SNMP objects Communities Users Groups Access to non volatile allows the user to delete these default SNMP entities like any other user created entity Spanning Tree Protocol PD4 863979218 PD4 814770957 VRRP PD4 861034486 PD4 855539430 An STP topology change triggers EAPS to flush FDBs and send FlushFdb PDUs despite the fact that none of the STP protected VLANs are participa
100. SPs using Advertised Implicit NULL Labels are Not Displayed The show mpls label show mpls rsvp te label and show mpls rsvp te 1lsp command output currently does not display egress LSPs using advertised implicit NULL labels PD3 111544904 Explicit NULL Labels are Treated as Implicit NULL Labels When a router receives an explicit NULL label it is incorrectly treated as an implicit NULL label so rather than sending label O no label is sent PD3 93218551 Packets with Router Alert Label 0x00001 are Not being Forwarded If either an egress or a transit LSP traverses the system and an MPLS labelled packet containing a router alert label is received that packet is not forwarded PD3 93069318 VLANs Configured as Protocol any Should be Added to MPLS Only VLANs configured as protocol any should be added to MPLS ExtremeXOS 12 1 4 Installation and Release Notes Table 32 Platform Specific and Feature PDs Continued PD Number PD3 104731701 Description ExtremeXOS Does Not Send Back ICMP Responses for Traceroute through Non Pipe Mode LSPs When a traceroute is performed by setting the MPLS TTL to the IP TTL ExtremeXOS does not correctly send back an ICMP response The result is characters in the traceroute for the routers that timed out If a route is available ExtremeXOS should attempt to send back an ICMP response PD3 93630853 LDP Should Not Advertise Certain Label Mappings LDP s
101. Session When a local user password expires logging into the switch using SSH will prompt you to change your password After changing the password the current SSH session will be terminated and you will need to login to the switch using the new password sFlow Does Not Work in BVLANs and SVLANs sFlow is not working on ports that are included in BVLANs SVLANs and occasionally vMANs sFlow can be enabled and configured for ports in BVLANs SVLANs and vMANs but nothing is sent to the sFlow collector SNMP PD3 206632121 SNMP Query for extremePortQosStatsTable OID Returns a Value of 0 On a Summit X450a series switch running an SNMP query for the extremePortQosStatsTable object identifier returns a value of O This should return the actual number of packets counted PD3 181304741 entPhysicalDescr MIB for XENPAK Modules Always Shown as XGM After inserting a XENPAK in a stack XGM2 2xn XGM 2xn and performing an snmpwalk on the entityMib entPhysicalDescr variable XGM is always shown not the complete module description PD3 39411271 icmpInMsgs Counter Displays only Incoming ICMP Packets icmpInMsgs counter will display the incoming ICMP packets for VR Default only Spanning Tree Protocol PD4 292225290 STP BPDUs are Generated When Connecting MSTP Configured Switch to Another Switch A large number of Spanning Tree Protocol STP BPDUs are generated when an MSTP configured switch is connected to another swit
102. Summit family switch experiences an intermittent interface diagnostics failure when extended diagnostics tests are run multiple times ERROR Transmitted 5 44M packets from slot 1 MAC O port 45 ERROR Received 4 01G packets on slot 1 MAC 0O port 45 ERROR Packets dropped 4 00G PD4 598343155 On a Summit X450 switch OSPF may not form an adjacency after enabling sFlow ACL PD4 964769251 An ExtremeXOS switch reboots with memory depletion for a 128 memory block while PD4 963068135 loading a flow redirect configuration ExtremeXOS 12 1 4 Installation and Release Notes Table 43 Platform Specific and Feature PDs Continued PD4 670315790 When configuring egress ACLs on a load shared port the following incorrect error message is displayed Duplicate ACL config Note Egress ACL need be applied on the Master port only CLEAR Flow PD4 852494655 With CLEAR Flow enabled CLEAR Flow ACL threads may be killed by EPM OSPF PD4 929585893 Incoming router LSAs with a router link greater than 420 causes the OSPF process to crash PD4 875793527 with an assertion failure PD4 896536108 When running OSPFv3 over a 6 in 4 tunnel interface OSPFv3 treats the interface as broadcast rather than point to point Resolved Issues in ExtremeXOS 12 1 3 patch1 9 The following issues were resolved in ExtremeXOS 12 1 3 patch1 9 The numbers shown in column one of the following table are for internal reference and can be ignored
103. a result IS IS graceful restart vendor interoperability is limited to devices which support draft ietf isis restart O3 or earlier PD3 190952336 Graceful Restart for IS IS May Fail for the Entire Node When one or more point to point interfaces are present on a router with IS IS graceful restart enabled the graceful restart may fail for the entire node Workaround Do not use point to point links if graceful restart is also used ExtremeXOS 12 1 4 Installation and Release Notes Table 32 Platform Specific and Feature PDs Continued PD Number PD3 183234835 Mirroring PD3 202013298 Description Graceful Restart Fails During restart process isis When one or more point to point interfaces are present on a router with graceful restart enabled the graceful restart may fail for the entire node Workaround Do not use point to point links if graceful restart is also used Use Valid Value Range for Configuring Remote Tags The valid value range for tags on remote mirroring VLANs is 1 to 4 094 Use these values for configuring the remote tag in the enable mirroring command PD3 202013281 PD3 79867211 PD3 28378521 MPLS PD3 208178928 Running the enable learning Command on Remote Mirroring VLANs May Cause a Loss of Traffic Learning is disabled by default on remote mirroring VLANs Running the enable learning command on those VLANs may cause a loss of remote mirrored traffic Mirroring Port Sho
104. ad sharing group or link aggregation group LAG vMAN ports can belong to LAGs If any port in the LAG is enabled for VMAN all ports in the group are automatically enabled to handle jumbo size frames Also VMAN is automatically enabled on all ports of the untagged LAG To verify your configuration use the show ports sharing command oO dd note All ports that are designated for the LAG must be removed from all VLANs prior to configuring the LAG Summit family of switches only does not apply to SummitStack The following guidelines apply to link aggregation on the Summit family of switches e One static LAG can contain up to 8 ports e An LACP LAG can include a maximum of 16 ports out of these up to 8 can be selected links and the remaining 8 will be standby links e A Health Check LAG can contain up to 8 ports ExtremeXOS 12 1 4 Installation and Release Notes e The default load sharing algorithm is L2 address based aggregation Any broadcast multicast or unknown unicast packets are transmitted differently depending on the device you are using m On the Summit X450 series switches these packets are transmitted on a single port of a LAG m On the Summit X150 X250e X350 X450a X450e and X650 series switches these packets are distributed across all members of a LAG e The maximum number of LAGs is 32 The available address based parameters on the Summit family of switches are as follows m Summit X450 series s
105. al name for the timezone DST on the Summit X450 family of switches the timezone name truncates at seven characters The system default is six characters PD3 57182431 RX Align Counter is Not Incremented For the incoming traffic with alignment errors the RX Align counter in the output of the show ports lt port number gt rxerrors command is not incremented Instead the RX CRC counter is incremented PD3 63858286 upload configuration Command Contains RIP Configuration Commands The upload configuration CLI command contains RIP configuration commands in spite of there not being a RIP VLAN Control Protocols PD3 125288233 MSTP Fails to Converge when Ethernet Type is 0x8100 MSTP fails to converge when a vMAN Ethernet type is set to Ox8100 on a BlackDiamond 12800 series switch Device Management PD3 126243853 HTTPS with Key Length of 4 096 has High CPU Utilization Using a key length of 4 096 in an SSL certificate causes high CPU utilization during HTTPS sessions Diagnostics PD4 285686375 EEPROM Error Message Appears in Log After Upgrade After upgrading to the latest ExtremeXOS 12 1 2 17 image the following EEPROM error message appears in the log 07 03 2008 12 30 03 72 MSM A MSM B card eeprom checksum failed Oxb97 0xb96 PD3 204419978 Repeatedly Running Diagnostics on MSM 48 or MSM G8x Modules May Fail Repeatedly running diagnostics on an MSM 48 or an MSM G8x module may sometimes fail resulting in the erro
106. ame from a supplicant When configuring and applying a certain ingress ACL traffic stops forwarding to ports belonging to the same vMAN Removing the ingress ACL restores traffic Static routes advertised to OSPF are lost after restarting OSPF when graceful restart is enabled A false alarm is occasionally generated even though the measured power is well below the power usage threshold 07 28 2008 07 27 05 threshold condition 07 28 2008 07 27 03 exceeding threshold 07 28 2008 07 27 00 threshold condition 07 28 2008 07 26 56 exceeding threshold 33 lt Noti PO cleared sl 12 lt Warn PO for slot 1 92 lt Noti PO cleared sl 51 lt Warn PO for slot 1 power_cleared gt Power usage ca power_exceeded gt Power usage Clo E a power_cleared gt Power usage t 1 power_exceeded gt Power usage Glo A The Object Identifier OID for a Summit X150 24 is missing from the MIB files The OID should have the form 1 3 6 1 4 1 1916 2 xx If you upload the MIB file to an SNMP browser all system identifiers are shown except for the Summit X150 Traps can now be sent to trap receivers on VR Default even when the default gateway is configured on VR Mgmt ExtremeXOS 12 1 4 Installation and Release Notes Table 57 Platform Specific and Feature PDs Continued Spanning Tree Protocol PD4 228364771 SSL PD3 29939091 A connection loss can occur when a boundary port transitions to a blocking state at the
107. amily Switches PD4 309137281 Disabling and enabling a GM 20XT I O module twice causes the slot to enter the Failed state and displays the following error message Error Generic Error 1 from HAL on CardExec POWER_OFF 10 for slot 1 During an ExtremeXOS software upgrade the following message may be seen when a Summit switch contains a large number of VLANs 08 14 2008 17 12 06 56 lt Crit HAL Sys Critical gt Switch low on Memory When the upgrade is complete the system reboots The saved configuration remains intact and is restored using the new ExtremeXOS image PD3 168702411 On a Summit X250e 24x when a link is connected to an SX SFP mini GBIC on one side and a 100 FX on the other side of the link the link is shown as being up on the 100 FX side but the link is down on the SX side ExtremeXOS 12 1 4 Installation and Release Notes Table 33 Platform Specific and Feature PDs Continued PD Number PD4 613216219 Description The following error message is seen when applying all_vlan to 70 or more VLANs SummitxX450a 24x 83 configure access list all_vlan vlan sh241 vlan Error ACL install operation failed meter hardware full for port 1 PD3 202962401 PD3 88458683 If you run the clear ipmc fdb command initially some multicast packets are forwarded in slowpath Those slowpath forwarded multicast packets are being denied by ACL PD3 76416480 When an egress ACL
108. amond 10808 and 20808 switches and Summit X450a and X650 series switches including SummitStack with LW XENPAK ports only The following command displays more specific information for the WAN PHY port on the LW XENPAK in port 1 of the Summit X450a 24t switch Port 1 Framing SONET Clocking Line LoopBack Off Trace Section alpha4 Trace Path delta6 History This command was first available in ExtremeXOS 10 1 Information on ingress rate shaping was added in ExtremeXOS 11 0 NetLogIn Smart Redundancy and rate limiting were added in ExtremeXOS 11 1 Information on unicast multicast and broadcast flooding the Port not present parameter and autopolarity status were added in ExtremeXOS 11 2 The netlogin parameters were added in ExtremeXO S 11 3 The BlackDiamond 12800 R series specific parameters were added in ExtremeXOS 11 4 Information on WAN PHY ports on the LW XENPAK modules on the BlackDiamond 10808 switch and the Summit X450a series switches was added in ExtremeXOS 11 6 The output command was modified in ExtremeXOS 12 1 so that when learning is disabled with the disabled learning port command a new w flag appears in the output TX Flow control was added in ExtremeXOS 12 1 2 patch 4 for the BlackDiamond 8800 series modules and the Summit family of switches RX Flow control was added in ExtremeXOS 12 1 3 Platform Availability This command is available on all platforms Information on WAN PHY ports on the LW XENP
109. ample The following command disables BGP from exporting routes from the OSPF protocol to BGP peers disable bgp export ospf History This command was first available in ExtremeXOS 10 1 This command required a specific license in ExtremeXOS 11 1 The blackhole option was added in ExtremeXOS 12 1 3 Platform Availability This command is available on platforms with the appropriate license For complete information about software licensing including how to obtain and upgrade your license and what licenses are appropriate for this feature see the ExtremeXOS Concepts Guide Appendix A ExtremeXOS Software Licenses ExtremeXOS 12 1 4 Installation and Release Notes enable bgp export enable bgp export blackhole direct isis isis level 1 isis level 1 external isis level 2 isis level 2 external ospf ospf extern1 ospf extern2 ospf inter ospf intra rip static address family ipv4 unicast ipv4 multicast export policy lt policy name gt Description Enables BGP to export routes from other protocols to BGP peers Syntax Description blackhole direct isis isis level 1 isis level 1 external isis level 2 isis level 2 external ospf ospf extern1 ospf extern2 ospf inter ospf intra rip static address family policy name Default Disabled Specifies blackhole routes Specifies direct routes Specifies ISIS routes Specifies ISIS level 1 routes Specifies ISIS l
110. anning Tree Protocol MSTP supports a revision level of 1 to 3 whereas other third party vendors support a revision level of O to 65535 Resolved Issues in ExtremeXOS 12 1 2 17 patch1 12 The following issues were resolved in ExtremeXOS 12 1 2 17 patch1 12 The numbers shown in column one of the following table are for internal reference and can be ignored ExtremeXOS 12 1 includes all fixes up to and including ExtremeXOS 11 1 4 4 ExtremeXOS 11 2 3 3 ExtremeXOS 11 3 4 5 ExtremeXOS 11 4 4 7 ExtremeXOS 11 5 2 10 ExtremeXOS 11 6 4 11 through patch1 8 and ExtremeXOS 12 0 3 16 through patch1 13 For information on those fixes see the release notes for the specific release Table 52 Platform Specific and Feature PDs PD Number Description General PD4 539428440 In some cases traffic ingressing an I O module is not egressing out load shared ports whose member ports are on a different I O module PD4 488646747 FDB entries are not learned for traffic that hits a service VLAN ID SVID translation policy Network Login PD4 399104181 When netlogin is configured with multiple authentication protocols on the same port the authentication response from one protocol should not override the already authenticated state of a client PD4 466032303 If the encrypted password entered for the CLI command configure netlogin add mac list lt mac gt encrypted contains the amp lt characters the configuration fails QoS PD4 39777
111. are redundant port Disabled auto polarity Enabled ExtremeXOS 12 1 4 Installation and Release Notes BlackDiamond 8800 series switch SummitStack and the Summit family of switches only The following command displays more specific information for slot 3 port 1 on a BlackDiamond 8810 switch show ports 3 1 information detail Following is sample output from this command Port Se Virtual router VR Default Type UTP Random Early drop Unsupported Admin state Enabled with auto speed sensing 100M Advertised auto duplex half duplex Advertised ELSM Link State Up Link State Active 1 Gbps full duplex Link Counter Up 1 time s VLAN cfg Name Default Internal Tag 1 MAC Based MAC limit No limit STP cfg s0 disable Tag none Mode 802 1D State FORWARDING Protocol Name Default Protocol ANY Match all protocols Trunking Load sharing is not enabled EDP Enabled ELSM Enabled Learning Enabled Unicast Flooding Enabled Multicast Flooding Enabled Broadcast Flooding Enabled Jumbo Enabled MTU 9194 Flow Control Rx Pause Enabled Tx Pause Disabled Link up down SNMP trap filter setting Enabled Egress Port Rate 128 Kbps Max Burst Size 200 Kb Broadcast Rate No limit Multicast Rate No limit Unknown Dest Mac Rate No limit QoS Profile QP3 configured by user Ingress Rate Shaping Unsupported Ingress IPTOS Examination Disabled Ingress 802 1p Exami
112. as first available in ExtremeXOS 10 1 The LACP feature was added in ExtremeXOS 11 3 The Health Check LAG was added in ExtremeXOS 12 1 3 Platform Availability This command is available on all platforms New FEF CLI Command The following CLI command enables and disables far end fault indication FEFI ExtremeXOS 12 1 4 Installation and Release Notes configure ports far end fault indication configure ports lt port_list gt far end fault indication on off Description Enables disables far end fault indication Syntax Description port_list Specifies one or more ports or slots and ports Default FEFI is disabled by default Usage Guidelines Use this command to enable FEFI When enabled FEFI signals to the remote end on detecting single link RX failure recovery The command is supported on FX LX and 100 FX GBICS FX LX GBIC should be operating in 100M mode Summit X450 24x and Summit X450a 24x platforms e Non combo GBIC ports that is ports 5 24 on the Summit X450 24x and ports 1 20 on the Summit X450a 24x If an attempt is made to use this command on combo ports it is rejected Since the GBICs can be plugged and removed a warning message is displayed in the syslog when a media type changes from FX LX and FX to another media type The warning messaage indicates that FEFI mode is enabled but is not useful for the new media type The current status is displayed in the show ports information detail co
113. ate a LAG One port in the LAG serves as the logical port for the LAG and is the reference port used in configuration commands When you create the LAG no monitoring is initially configured The LAG is created in the same way that a static LAG is created and if no monitoring if ever created this LAG behaves like a static LAG 1 Create a LAG using the following command enable sharing lt port gt grouping lt port_list gt algorithm port based address based L2 L3 L3_L4 lacp health check The port you assign using the lt port gt parameter becomes the logical port for the link aggregation group and the LAG Group ID when using Health Check link aggregation This logical port must also be included in the port list of the grouping itself 2 Configure monitoring for each member port using the following command configure sharing health check member port lt port gt add tcp tracking lt IP Address gt tcp port lt TCP Port gt frequency lt sec gt misses lt count gt If the TCP port frequency or misses are not specified the defaults described in the ExtremeXOS Command Reference Guide are used 3 Add the LAG to a VLAN whose subnet is the same as the configured tracking IP addresses ExtremeXOS 12 1 4 Installation and Release Notes configure vlan lt vlan gt add port lt lag port gt tagged untagged All of the tracking IP addresses must be in the same subnet in which the LAG belongs dd note VLANs
114. atform Availability This command is available on all platforms ExtremeXOS 12 1 4 Installation and Release Notes enable sharing grouping enable sharing lt port gt grouping lt port_list gt algorithm port based address based L2 L3 L3_L4 lacp health check Description Enables the switch to configure port link aggregation or load sharing By using link aggregation you use multiple ports as a single logical port Link aggregation also provides redundancy because traffic is redistributed to the remaining ports in the LAG if one port in the group goes down LACP allows the system to dynamically configure the LAGs Syntax Description port Specifies the master logical port for a load sharing group or link aggregation group LAG port_list Specifies one or more ports or slots and ports to be grouped to the logical port port based Specifies link aggregation by port based algorithm NOTE This parameter is available only on the BlackDiamond 10808 and the BlackDiamond 12800 series switches address based Specifies link aggregation by address based algorithm L2 Specifies address based link aggregation by Layer 2 This is the default value NOTE This parameter is available only on the BlackDiamond 8800 series switch SummitStack and the Summit family of switches L3 Specifies address based link aggregation by Layer 3 NOTE This parameter is available only on the BlackDiamond 8800 series switch SummitStack an
115. ave greater than 25 000 total IP routes from all routing protocols Adverse effects can occur with routing tables larger than this especially when a single network event or CLI command affects a significant number of routes For example just after such a network event the added system load will cause a save configuration command to time out Table 31 Supported Limits Metric Product Access lists masks maximum number of ACL BlackDiamond 8800 original series 16 TEIS par porke Summit X450 16 Access lists policies suggested maximum BlackDiamond 10808 300 000 number of lines in a single policy file BlackDiamond 1200 Sies 300 000 ExtremeXOS 12 1 4 Installation and Release Notes Metric Product Limit Access lists policies maximum number of BlackDiamond 8800 series i j icy file b rules in a single policy file Original series modules per GigE port 128 per 10 GigE port 1 016 c series modules 4 096 a series modules 2 048 e series modules 1 024 BlackDiamond 10808 30 000 Summit X150 and X350 series 1 024 Summit X250e per port groups 1 24 and 25 48 1 024 Summit X450 per GigE port 128 per 10 GigE port 1 016 Summit X450a per port groups 1 24 and 25 48 2 048 Summit X450e per port groups 1 24 and 25 48 1 024 Access lists slices maximum number of field BlackDiamond 8800 series selesi 1r AGL eliges c series and a series modules per port groups 1 12 25 36 and 13 24 37 48
116. aximum number BlackDiamond 10808 32 of MPLS LDP configured interfaces per switch BlackDiamond 12800 R series 32 MPLS LDP peers maximum number of MPLS BlackDiamond 10808 32 LDP peers par awien BlackDiamond 12800 R series 32 MPLS LDP adjacencies maximum number of BlackDiamond 10808 50 MPLS LDP adjacencies per switch BlackDiamond 12800 R series 50 ExtremeXOS 12 1 4 Installation and Release Notes Metric Product Limit MPLS LDP labels maximum number of MPLS BlackDiamond 10808 20 000 LDP lelbels per swich BlackDiamond 12800 R series 18 000 It may take a long time to converge and populate the labels in hardware MPLS static LSPs maximum number of static BlackDiamond 10808 1 000 Eos BlackDiamond 12800 R series 1 000 MSDP active peers maximum number of active BlackDiamond 8800 series 32 WSDP pess BlackDiamond 10808 32 BlackDiamond 12800 series 32 Summit X450 16 MSDP SA cache entries maximum number of BlackDiamond 8800 series 16 000 eres in SA cane BlackDiamond 10808 16 000 BlackDiamond 12800 series 16 000 Summit X450 8 000 MSDP maximum mesh groups maximum number BlackDiamond 8800 series 8 w ESE mesh groups BlackDiamond 10808 8 BlackDiamond 12800 series 8 Summit X450 4 Multicast VLAN registration MVR maximum BlackDiamond 8800 series 1 024 numbegofsendersipedswiteni BlackDiamond 8800 c series 2 048 BlackDiamond 10808 15 000 BlackDiamond 12800 series 15 000 Summit series 1 024
117. ble A port can only be added to a VLAN if there is at least 30MB of memory available Currently one of these limits will be encountered if approximately 2 500 VLANs with eight ports each are configured evenly Changing the order in which VLANs are created and ports are added may result in different configurations at the time a limit is encountered Also since memory is shared with other features for example route tables the number of VLANs and ports that can be created may be considerably lower ExtremeXOS 12 1 4 Installation and Release Notes Resolved Issues in ExtremeXOS 12 1 4 patch1 9 The following issues were resolved in ExtremeXOS 12 1 4 patch1 9 The numbers shown in column one of the following table are for internal reference and can be ignored ExtremeXOS 12 1 includes all fixes up to and including ExtremeXOS 11 1 4 4 ExtremeXOS 11 2 3 3 ExtremeXOS 11 3 4 5 ExtremeXOS 11 4 4 7 ExtremeXOS 11 5 2 10 ExtremeXOS 11 6 5 3 patch1 5 and ExtremeXOS 12 0 5 For information on those fixes see the release notes for the specific release Table 34 Platform Specific and Feature PDs PD Number Description General PD4 812156545 The CLI command show fdb lt name of the private vian gt output loops for specific MAC addresses PD4 1142795450 In some cases EXOS CLI allows load sharing group to be formed using ports with different link speeds PD4 935914533 Getting inconsistent Destination Host Unreachable retu
118. ble 45 Platform Specific and Feature PDs PD Number General PD4 505794657 Description Repeatedly running multiple commands from a telnet session causes memory depletion in the exsh process PD4 791833227 If an IPv6 tunnel is configured adding a static route causes the Route Table Manager to crash with a signal 11 error PD4 767856469 After running the save command and rebooting a switch with a VLAN translation configuration duplicate packets are sent to member VLANs from the translation VLAN PD4 862521622 BlackDiamond 12 PD4 907885458 PD4 907885450 Receiving bootstrap packets with a Fragment Tag field set to zero causes memory depletion in the PIM process when processing subsequent bootstrap packets 800 Series Switch SerDes register values have been corrected for optimum performance PD4 852419857 Creating and deleting HQoS queues on a BlackDiamond 12808 results in the following error Error Timeout awaiting Traffic Queue operation PD4 723664780 After performing a hitless upgrade from ExtremeXOS 12 0 or later to ExtremeXOS 12 1 or later packets are sent to the CPU for L3 switching even though hardware entries exist for the destination IP ExtremeXOS 12 1 4 Installation and Release Notes Table 45 Platform Specific and Feature PDs Continued Summit Family Switches PD4 911150963 Changing L3 adjacency between trunked and non trunked ports causes traffic to be PD4 91121
119. ble are for internal reference and can be ignored ExtremeXOS 12 1 includes all fixes up to and including ExtremeXOS 11 1 4 4 ExtremeXOS 11 2 3 3 ExtremeXOS 11 3 4 5 ExtremeXOS 11 4 4 7 ExtremeXOS 11 5 2 10 ExtremeXOS 11 6 5 3 patch1 5 and ExtremeXOS 12 0 5 For information on those fixes see the release notes for the specific release Table 37 Platform Specific and Feature PDs PD Number Description General PD4 1175951471 VLAN mirroring cannot mirror packets that are ingressing a LAG port when the master PD4 1085211320 port link is disabled BlackDiamond 12800 Series Switch PD4 1217032435 When disabling and enabling a BGP peer with 15 000 routes multiple times an assertion PD4 1191404997 failure occurs and the BGP process crashes with signal 6 PD4 1232462236 A hardware error may occur on a BlackDiamond 12800 series switch resulting in a misread on the backplane SerDes FPGAs This misread is interpreted by the system health check as an error which in turn may cause an I O module or MSM to be taken offline ExtremeXOS 12 1 4 Installation and Release Notes Resolved Issues in ExtremeXOS 12 1 4 patch1 5 The following issues were resolved in ExtremeXOS 12 1 4 patch1 5 The numbers shown in column one of the following table are for internal reference and can be ignored ExtremeXOS 12 1 includes all fixes up to and including ExtremeXOS 11 1 4 4 ExtremeXOS 11 2 3 3 ExtremeXOS 11 3 4 5 ExtremeXOS 11 4 4 7 ExtremeXOS
120. ch that is using a default configuration PD3 189927343 Stacking PD3 136493921 Temporary Loop Occurs When a Root Bridge is Taken Down A temporary loop occurs when a root bridge is taken down by disabling all ports or powering down the switch AAA Services Do Not Become Available on Stacking Switch that has a Mismatched License If a switch is added to a stack whose master switch has a license level that is greater than the level of the switch the switch will fail The complete condition can be seen using the show slot detail command In this state the switch does not have AAA services available You will only be able to log into the switch using the failsafe account that was last assigned to it You must log into the switch to upgrade the license If the switch is not using the failsafe account configured on the stack you can use the synchronize stacking node address lt node address gt slot lt slot number gt command to copy the failsafe account information from the master switch to the failed switch NVRAM You can also use the configure stacking license level command to configure a license level restriction on the entire stack and then reboot the stack Once the stack is restarted there is no longer a license mismatch enabling you to log into the switch and upgrade the license From the master switch run the unconfigure stacking license level command to get the stack to operate at the desired license and then reboot the
121. ches cccecceeeeeeeeeeeeees 92 Tested Third Party Produets seseris irinotecan orae Eaa AAE EET EELO ONST ssaneeddvnered febexeeessdeaveseeds 94 Tested RADIUS Servers ccccccccccccc cece ee cece eee e cence eee rende FTESE ETEen Eend A anere E hE E ASAREE Eria rE E Eht 94 Tested Third Party Chentsec i oenas r eE E EEOAE 94 PoE Capable VolP PRONES i c c0cs2cciscsec eensdescddenchecessicdance di dadadeescdaseedieesicdeedadesendadesecesseedanteadeas 94 Extreme Switch Security Assessment c cccecccececceee eee eeseeceeee eee eeseeseeeeeeeeeseeeeeseesaeeeeeaeeseeeeeeneegs 95 DoS Attack Assessment ccccccecceeceeceeee ees eceeseeee eee eee eeeeeee eee eee eeeeeseeseeseesseeeeeaeeseeseeeeeaeeaeegaes 95 ICMP Attack ASSESSMENT sess cseecesiwceecsavsaisecestoccsisiycesecdectwaveas avcebeoevesevkecdwedeciwersibavsosteeecsecens 95 Port Scan Assessment c ccceccececeeceeceee eee eceeeeeee eee ees eeseeee eee ees eseeeeeeeeeseesseeeeeeeeeaesaeseeeseeaeesges 95 Chapter 2 Upgrading to ExtremeXOS 12 1 cccsssssssessssceesesssececsssseeeeeesseceesesssaeecssssneeeeenseneesees 97 SLAVING CUM Git arises ene E gue savaceussnayacvarts E E E EE E 97 Upgrading ExtreMeXO Se iiciin iaaiaee ener ENAERE P EAE EEE EON rea ERE ARR EEn St 97 WICK e E E E E A A E E A T A I E 98 Detailed STDS erriren inn E E a ERE EE AT EE ESEE RARE EEAO ET ORNA Ei 99 Upgrading ExtremeXOS on a Summit X150 and X350 s ss ssssssssssssrrrsrrrerrrrerrrr
122. correctly with large packets such as 256 512 and 1 024 The traffic fluctuates between different rates when the packet size is above 200 PD3 86738591 Traffic Queue Statistics are Incorrect when Switch is Configured Traffic queue statistics are incorrect when a BlackDiamond 12800 series switch is configured to work in H QoS mode Statistics counters are accurate when the switch is configured in the PRI mode PD3 98333969 Disabling and Enabling a Port Can Take 30 Seconds for Port to Activate During continuous FDB learning disabling enabling a port can take up to 30 seconds for the port to activate Summit Family of Switches PD4 310814981 When Configuring a Set of ACLs Performing a Save and a Reboot Generates an Error When configuring a set of ACLs on a Summit X450a 48t switch the access control lists are successfully applied however performing a save and a reboot generates an error PD3 204517991 Summit X250e 24x Combo Port Link May Come Up With the Correct Speed But in Half Duplex Mode A Summit X250e 24x combo port link may come up with the correct speed but in half duplex mode even though the switch is configured as full duplex mode when autonegotiation is set to off on both sides of the link For the link to come up in full duplex mode as configured you must disable and enable the port or restart the port PD3 201233169 Port Does Not Come up After Disable Enable or Reboot on Some Mitel IP Phone
123. d Down Disabled Down Disabled Down Disabled Down Disabled Down Disabled Down Disabled Down Disabled Down Disabled Down Disabled Disabled 2048 2048 2048 2048 2048 2048 2048 2048 2048 2048 2048 This command required a specific license in ExtremeXOS 11 1 Platform Availability This command is available on platforms with the appropriate license For complete information about software licensing including how to obtain and upgrade your license and what licenses are appropriate for this feature see the ExtremeXOS Concepts Guide Appendix A ExtremeXOS Software Licenses ExtremeXOS 12 1 4 Installation and Release Notes show bgp routes show bgp routes address family ipv4 unicast ipv4 multicast detail all as path lt path expression gt community no advertise no export no export subconfed number lt community_num gt lt AS_Num gt lt Num gt network any lt netMaskLen gt lt networkPrefixFilter gt exact Description Displays the BGP route information base RIB Syntax Description address family all no advertise no export no export subconfed community_num AS_Num Num any netMaskLen networkPrefixFilter exact Default The address family BGP supports two address families IPv4 Unicast and IPv4 Multicast Specifies all routes Specifies the no advertise community attribute Specifies the no export community attribute Specifies the no export s
124. d algorithm has a more even distribution and is the recommended choice oO dd Note You must use the configure sharing address based command to configure address based load sharing on the BlackDiamond 10808 BlackDiamond 12800 and BlackDiamond 20808 series switches Example The following example adds port 3 13 to the LAG with the logical port 3 9 on a modular switch configure sharing 3 9 add port 3 13 History This command was first available in ExtremeXOS 10 1 Platform Availability This command is available on all platforms ExtremeXOS 12 1 4 Installation and Release Notes configure sharing health check member port add tcp tracking configure sharing health check member port lt port gt add tcp tracking lt IP Address gt tcp port lt TCP Port gt frequency lt sec gt misses lt count gt Description Configures monitoring for each member port of a health check LAG Syntax Description port Specifies the member port IP Address Specifies the IP address to monitor TCP Port Specifies the TCP port to watch The default is port 80 sec Specifies the frequency in seconds at which tracking takes place The default is 10 seconds count Specifies the number of misses before a connection loss is reported The default is 3 misses Default N A Usage Guidelines To configure a health check LAG you first create a health check type of LAG using the enable sharing grouping command Then use this command
125. d for a Default Route in a Stub Area When an OSPF neighbor is configured between two LSRs and MPLS and an LDP session is configured between them the ABR router advertises a default route to the internal router The default route is not mapped to a label in the internal router because the ABR does not advertise the label PD3 97057691 Mirrored RSVP Path Message Packets have Incorrect IP Header Checksums When creating a mirrored port and viewing all traffic on a BlackDiamond 10808 the RSVP path packets have incorrect checksums These path messages occur on egress traffic from the BlackDiamond 10808 PD3 109748431 show tech Command Shows Erroneous MPLS CLI on a Non MPLS License System The show tech command shows erroneous MPLS CLI on a non MPLS license system running on a BlackDiamond 10808 MPLS should determine if the system is MPLS licensed and only then show the CLI PD3 188594038 PD3 133340423 LDP Adjacency Breaks after Enabling PHP Feature The PHP feature will not work correctly and may break LDP adjacency with its neighbors Currently there is no workaround PD3 99318269 show mpls rsvp te Isp detail Command may Not Show Error Condition If the transmit bandwidth between two RSVP TE neighbors is sufficient for a given LSP but the receive bandwidth is not the LSP does not come up The reason for the error is not displayed in the show mpls rsvp te lsp detail output PD3 92653036 Egress L
126. d miss settings A typical use case for this application is when a user wishes to connect each member link to a Security Server to validate traffic Each member link of the Health Check LAG is connected to an individual Security Server The LAG is added to a VLAN on the same subnet as the Security Server IP addresses they wish to monitor Each member port is configured to monitor a particular IP address and TCP port The Health Check LAG application attempts to do a TCP connect to each IP TCP port through each member port The Health Check LAG by virtue of the sharing algorithm will load balance traffic across the member links If a TCP connection cannot be established through the member link the port is removed from the aggregator and traffic through that particular link is redistributed to the other LAG member links Figure 1 displays an example of a Health Check LAG ExtremeXOS 12 1 4 Installation and Release Notes Figure 1 Health Check LAG Example HEALTH CHECK LAG Application Controls this LAG or Trunk Group Server1 192 168 1 101 Extreme XOS v1 192 168 1 1 r o Server2 192 168 1 102 Connect and Server3 monitor TCP port 192 168 1 103 on each individual link 1 3 removed from LAG Server4 192 168 1 104 No response from specified TCP port NOTE Default port to monitor is 80 HTTP Configuring Health Check Link Aggregation To configure Health Check link aggregation you must first cre
127. d the Summit X450 series switch L3_L4 Specifies address based link aggregation by Layer 3 IP plus Layer 4 port NOTE This parameter is available only on the BlackDiamond 8000 a series c series and e series modules and the Summit X250e X450a X450e and X650 series switches whether or not included in a SummitStack lacp Specifies dynamic link aggregation or load sharing using the LACP health check Specifies a health check type of link aggregation group Default Disabled Usage Guidelines Link aggregation or load sharing allows you to increase bandwidth and availability between switches by using a group of ports to carry traffic in parallel between switches The aggregation algorithm allows the switch to use multiple ports as a single logical port For example VLANs see the link aggregation group LAG as a single logical port Groups can span multiple modules dd NOTE All ports that are designated for the LAG must be removed from all VLANs prior to configuring the LAG ExtremeXOS 12 1 4 Installation and Release Notes You can enable and configure dynamic link aggregation using LACP or health check link aggregation Static link aggregation is the default link aggregation method oO dd NOTE Always verify the LACP configuration by issuing the show ports sharing command look for the ports listed as being in the aggregator If a port in a LAG fails traffic is redistributed to the remaining ports in the LAG
128. detuate 5 Configuration Change in ExtremeXOS 12 1 sssssnssnnsresreerrsrrsrrrsrsrinsrrrrrrrrerrerrnrrnrrerrrrrrrrrrrrerrent 5 Feature Enhancements in ExtremMeXOS 12 1 3 ccccccccccccceeccseceeeceeeeeeeeeeeeeee cess eeseeeseeeseeeeseeegeeeaeeeeaes 5 BGP Enhancements cccccccecceccececeec scence eee eeeeee eee eee eee trr nese eee eee reren eee eseesaeseeeaeeaeeeeeeeneneeaeeggs 5 Flow Control Summit Family of Switches and BlackDiamond 8800 Series Switches Only 32 STP and Network Login ccccccccecccseee cess eeee eee eeeeeeeeeeseeeee sees eeeee esse esse eeseeeseeeseeesaeesaeeeeneeeaes 45 Health Check Link Agsresatiomi cssccsisesiasieccssacddivetedsGevesiveudiesieassacd EEE EEE E EEE EEEE EE iaai 47 New FEFI CLI Command ccccccceccscceeceeeeeeceeceeee eee ees eeeeeeeeeeeeeeseeeeeeeeeseeseeseeeeeaeeaeeeeeeeeeneeges 64 New Features or Feature Enhancements in ExtremeXOS 12 1 2 17 0 cccccccccceccceecceecceeeeeeeeeeeeeeees 66 New Hardware Supported in ExtremeXOS 12 1 2 17 cccccccccccccccsecceeeeesecee esse eesseeseeeseeeseeeesneeaaeeees 66 New Features in Extre mMeXOS 12 1 oo cccccccccssccsecee cece eeseeeceeeseeeeeeeeee esse esse eeseeeseeesseeeaeeesaeenaeeees 67 New Hardware Supported in ExtremeXOS 12 1 1 4 wo ccccccccecccseceeeeeee cess cess eeseeceeeeseeesseeeaeeeneeeees 69 Supported HArdWware ccccccccccecceec eee ee cece eee eee AE EEE EEE EGA EAE AEA OE Ea EEEE EG EE S Eea EELEE EEG aR OEE E
129. dress owner WAN PHY PD3 101226461 WAN PHY show Commands Should Not be Applied to non WAN PHY Ports When show wan phy commands are run on non WAN PHY ports the ports display the headers It should only display the error wan command is not supported on non wanphy port 25 Known Behaviors The following are limitations in ExtremeXOS system architecture that will not be resolved Table 33 Platform Specific and Feature PDs PD Number Description General PD4 995543551 When configuring an ip mtu as 9 216 the value is reduced to 9 194 after upgrading to ExtremeXOS 12 1 or later PD4 440122302 Log messages should not be flooded when an ARP violation occurs which is causing the EMS server to be busy PD4 765092558 When RADIUS authentication for a MAC based network login IP address fails a UPM profile generates a warning message ExtremeXOS 12 1 4 Installation and Release Notes Table 33 Platform Specific and Feature PDs Continued PD Number PD3 197435644 Description LACP with address based algorithms on L2 links is sending multicast traffic on multiple links PD3 204022938 If a MAC move occurs in an isolated subscriber VLAN without the link of the port going down the MAC address is not learned on the new port PD3 182634820 The thttpd process cannot be restarted using the start process or restart process commands after the process exits preceded by a Thread thttpd ID does not
130. dule ExtremeXOS 12 1 4 Installation and Release Notes Table 29 Summit X150 and X350 Supported Commands Continued neighbor discovery Command Description iproute IP routing module ipstats IP statistics 2stats Layer 2 statistics lacp LACP Link Aggregation Control Protocol licenses Switch licenses IIdp Configure LLDP specific settings log Show information related to logging mac lockdown timeout MAC lockdown with timeout management Management memory Memory statistics meter METER help mirroring Mirroring mld MLDP myr Multicast VLAN registration IPv6 neighbor netlogin Show network login specific information odometers Odometers policy Policy ports Ports power Power information process Process information protocol Protocol qosprofile QoS profile radius RADIUS and RADIUS accounting configuration radius accounting RADIUS client accounting rmon RMON CLI command session Show active sessions sflow Show sFlow configuration snmpv3 SNMPv3 sntp client Show configuration and statistics ssl SSL setup stpd STP domain switch Switch information tacacs TACACS configuration tacacs accounting TACACS client accounting tech Technical support information temperature Temperature tunnel udp echo server Tunnel Show the UDP echo server configuration version vlan Version information VLAN Extrem
131. e 15 Summit X450a Switch SFP Support SFP ExtremeX0S Required 10 100 1000BASE T Copper SFP 12 0 2 25 Note Not supported on combo ports SX SFP 11 2 2 4 LX SFP 11 2 2 4 ZX SFP 11 2 2 4 100FX SFP 11 6 1 9 Note Not supported on combo ports 100FX 1000LX SFP 11 6 1 9 e Summit X450a 24x ports 1 through 20 Note Not supported on combo ports LX100 SFP 12 0 1 11 1000BX SFP 11 6 1 9 SFPs supported on the Summit X450e switch with ExtremeXOS 12 1 and the minimum ExtremeXOS version required include Table 16 Summit X450e Switch SFP Support SFP ExtremeXOS Required SX SFP 11 6 1 9 LX SFP 11 6 1 9 ZX SFP MTSE ExtremeXOS 12 1 4 Installation and Release Notes Table 16 Summit X450e Switch SFP Support SFP ExtremeXOS Required LX100 SFP 12 0m 1000BX SFP IIL 6 1 SFPs supported on the Summit X250e switch with ExtremeXOS 12 1 and the minimum ExtremeXOS version required include Table 17 Summit X250e SFP Support SFP ExtremeXOS Required SX SFP ports 25 and 26 12 0 2 25 LX SFP ports 25 and 26 12 0 2 25 ZX SFP ports 25 and 26 12 0 2 25 LX100 SFP ports 25 and 26 12 0 2 25 1000BX SFP ports 25 and 26 12 0 2 25 1OOBASE FX FE ports SFP ports 1 through 26 12 0 2 25 Note Not supported on combo ports 1OOBASE BX SFP ports 1 through 26 12 0 2 25 Note Not supported on combo ports 1OOBASE LX10 SFP ports 1 through 26 12 0 2 25 Note Not suppo
132. e two failovers are required for a dual MSM firmware installation you will not need to run the reboot command after executing the install firmware procedure e dd note Upgrading a BlackDiamond 12804 slot can take a minimum of six minutes per slot BD 12804 7 install firmware Installing version 1 0 0 2 of the MSM bootrom s Do you want to continue y yes n no lt cr gt cancel Yes Installing IO module firmware a reboot is required Do you want to continue y yes n no lt cr gt cancel Yes Installing version 2 13 of the PSU control module firmware Do you want to continue y yes n no lt cr gt cancel Yes Installing micro controller image on backup MSM requires rebooting backup MSM Do you want to continue y yes n no lt cr gt cancel Yes talling bootrom talling bootstrap talling active bootrom talling system FPGA image talling bootstrap talling active bootrom D n o o p p fb 8 talling system FPGA image MSM bootrom s installed successfully MSM bootrom s will be activated upon next MSM reboot Installing bootrom ExtremeXOS 12 1 4 Installation and Release Notes Installing microcontroller firmware to slot 1 Installing FGPA firmware to slot 1 This will takes a few minutes Installing microcontroller firmware to slot 2 Installing FGPA firmware to slot 2 This will takes a few minutes Installing microcontroller firmware to slot 5 Installing
133. e was used at the last reboot Output from this command includes the version of the selected and booted images and if they are in the primary or the secondary partition In this example the selected and booted images are in the primary partition Image Selected primary Image Booted primary Primary ver LA 26 1 7 Secondary ver 11 6 1 7 Config Selected primary cfg Config Booted primary cfg Select the download partition and partition to use on reboot Specify the partition by issuing the following command ExtremeXOS 12 1 4 Installation and Release Notes use image pri OR use image sec 6 Download and install the image to the switch Download and install the image to the switch using the download image command The virtual router lt vr gt that you will use is the one you determined in step 2 This example assumes that you are using virtual router vr mgmt and TFIP server 192 168 0 12 Substitute your own virtual router and IP address when you run the command download image 192 168 0 12 bd10k 12 1 3 x0os vr vr mgmt This may not be the actual filename it is just an example You will be asked Do you want to install image after downloading y yes n no lt cr gt cancel Answer y for yes so that the image will be installed after downloading 7 Reboot the switch Use the reboot command to reboot the switch Oo dd note For the BlackDiamond 8800 series of switches You will be prompted to upgrade the BootROM
134. eXOS 12 1 4 Installation and Release Notes Table 29 Summit X150 and X350 Supported Commands Continued Command vman Description vMAN lt eapsDomain gt lt name gt EAPS domain name ESRP domain name lt stpd_name gt STP domain name lt vlan_name gt VLAN name start Start process process Process telnet Telnet client vr Virtual router lt host_name gt lt remote_ip gt Remote host name Remote telnet server IP address terminate Terminate running process process Process information tftp TFTP client get Get file put Put file lt host name gt Remote TFTP server host name lt ip address gt Remote TFTP server address top Display system utilization traceroute Trace route to an IP address ipv4 Force use of IPv4 transport ipv6 Force use of IPv6 transport vr Traceroute from virtual router ID lt host gt IPv4 host to traceroute unconfigure Unconfigure system configuration access list Access list bootprelay BOOTP relay agent information option diffserv Diffserv eaps EAPS Ethernet Automatic Protection Switching elrp client ELRP Extreme Loop Recovery Protocol Client icmp ICMP option igmp IGMP inline power Inline power iparp IP ARP command IIdp Configure LLDP specific settings log Configure log service mld MLD protocol mstp MSTP configuration netlogin Configure network l
135. eXOS 12 1 includes all fixes up to and including ExtremeXOS 11 1 4 4 ExtremeXOS 11 2 3 3 ExtremeXOS 11 3 4 5 ExtremeXOS 11 4 4 7 ExtremeXOS 11 5 2 10 ExtremeXOS 11 6 5 3 patch1 5 and ExtremeXOS 12 0 5 For information on those fixes see the release notes for the specific release Table 43 Platform Specific and Feature PDs PD Number Description General PD4 899333484 The thttpd process CPU utilization increases and HTTP HTTPS is not accessible if sock stress attack is performed on an HTTPS port This issue persists indefinitely even after a sock stress attack is removed PD4 924242747 The FDB process may die with signal 11 when the show fdb statistics command is executed PD4 920567275 Process FDB may die with signal 11 when processing SNMP Get requests for dotldTpFdbTable PD4 767595507 The log filter is not shown in the output of the show upm profile lt profile name gt command PD4 978931780 When stacking redundancy and telnet access profiles are configured the following error is PD4 975759347 displayed Connection refused Connection closed by foreign host BlackDiamond 12800 Series Switch PD4 832095668 The ACL match condition ports ingress lt port no gt causes incoming packets to be forwarded to all ports in a VLAN as per the VLAN tag for incoming packets even though the ingress port is not part of that VLAN Summit Family Switches PD4 816941511 The following error may be seen when a
136. ease Notes Resolved Issues in ExtremeXOS 12 1 4 patch1 7 The following issues were resolved in ExtremeXOS 12 1 4 patch1 7 The numbers shown in column one of the following table are for internal reference and can be ignored ExtremeXOS 12 1 includes all fixes up to and including ExtremeXOS 11 1 4 4 ExtremeXOS 11 2 3 3 ExtremeXOS 11 3 4 5 ExtremeXOS 11 4 4 7 ExtremeXOS 11 5 2 10 ExtremeXOS 11 6 5 3 patch1 5 and ExtremeXOS 12 0 5 For information on those fixes see the release notes for the specific release Table 36 Platform Specific and Feature PDs PD Number Description General PD4 828470206 The invalid syntax keyword tag_name is added when configuring a syslog target BlackDiamond 10808 Switch PD4 804225168 ESMI related warning messages are seen in the output of the show log command whenever an SSL certificate with a key length of 4 096 is created or the HTTPD process is restarted ACL PD4 1027427745 The ACL action modifier log does not work with IGMP ACL PD4 1027427581 For ACL counters for IGMP message type the direct offset is calculated and the protocol type in the IP header is not checked Therefore any IP datagram matching the offset is counted as matching Workaround Set a protocol igmp match condition explicitly in the policy file Resolved Issues in ExtremeXOS 12 1 4 patch1 6 The following issues were resolved in ExtremeXOS 12 1 4 patch1 6 The numbers shown in column one of the following ta
137. educe the number of LAGs to 32 you must reboot the system or stack first The system logs an error message at the error level similar to the following when you must reduce the system even if you reduced the number of LAGs to 32 04 07 1921 23 52 28 29 lt Erro HAL Card Error gt MSM A Slot 8 is not supported when more than 32 load share groups have previously been configured A system reboot is required to clear this condition When you have BlackDiamond 8800 original series modules and BlackDiamond 8000 a series c series and e series modules in the same chassis or when you have original Summit X450 switches and X650 ExtremeXOS 12 1 4 Installation and Release Notes X450a X450e or X250e switches in the same SummitStack the configured algorithm may behave differently as shown in the following Configured BlackDiamond 8800 original series BlackDiamond 8000 a series c series and e algorithm module or Summit X450 series switch series modules or SummitStack with Summit X650 X450a X450e or X250e switch L2 L2 L2 with flooding and multicast traffic balanced L3 L3 L3 and L4 ports L3_L4 L3 L3 and L4 ports BlackDiamond 10808 BlackDiamond 12800 and BlackDiamond 20808 series switches only The following guidelines apply to load sharing on the BlackDiamond 10808 12800 and 20808 series switches e A static LAG can include a maximum of 16 ports e An LACP LAG can include a maximum of 32 ports out of these up to 1
138. egation setup if a PD4 727955846 DHCP request is received on a subVLAN OSPF PD4 885811009 Deleting ports and unconfiguring IPv6 adresses on a Summit X450a switch causes an OSPFv3 assertion failure Resolved Issues in ExtremeXOS 12 1 4 patch1 2 The following issues were resolved in ExtremeXOS 12 1 4 patch1 2 The numbers shown in column one of the following table are for internal reference and can be ignored ExtremeXOS 12 1 includes all fixes up to and including ExtremeXOS 11 1 4 4 ExtremeXOS 11 2 3 3 ExtremeXOS 11 3 4 5 ExtremeXOS 11 4 4 7 ExtremeXOS 11 5 2 10 ExtremeXOS 11 6 5 3 patch1 5 and ExtremeXOS 12 0 5 For information on those fixes see the release notes for the specific release Table 41 Platform Specific and Feature PDs PD Number Description General PD4 1027500181 The show tech all detail logto file command does not complete execution PD4 1087700914 PIM DM causes higher bandwidth consumption with multicast when no subscribers exist PD4 698458422 ExtremeXOS 12 1 4 Installation and Release Notes Table 41 Platform Specific and Feature PDs Continued PD Number General IGMP PD4 926340897 Description Even with IGMP proxy enabled when an IGMP subscriber leaves the IGMP leave is forwarded with multiple subscribers on one port Resolved Issues in ExtremeXOS 12 1 4 patch1 1 The following issues were resolved in ExtremeXOS 12 1 4 patch1 1 The numbers shown in column one
139. ell you must first download and install the CLI Proxy application on your desktop The CLI Proxy installer is available at the Tech Support web site ACL byte counters as an alternative to ACL packet counters EAPS enhancements m ESD configurable timers e Anycast Rendezvous Point RP mechanism using Protocol Independent Multicast PIM and Multicast Source Discovery Protocol MSDP e vMAN enhancements m Per VLAN IGMP snooping m Service Tag STAG EtherType m Tagged and untagged support e vMAN ingress ACL support to enable and disable IGMP snooping VLAN enhancements m Aggregation m Translation m Private VLANs e Universal ports enhancements m EMS integration m Additional triggers m Actions e Multicast VLAN Registration MVR scaling enhancements for IGMP Routing table enhancements m Implementation of multicast routing table m Segregation of unicast and multicast routing table PIM snooping MPLS enhancements m Hierarchical Virtual Private LAN Services HVPLS L2 VPNs m Static LSPs m Pseudo wire Virtual Circuit Connectivity Verification VCCV m Protected VPLS IS IS v4 and IS IS v6 IPv6 ECMP load balancing BlackDiamond 10808 and BlackDiamond 12800 series switches Extended IPv4 host cache by way of configurable LPM table size for ExtremeXOS 12 1 4 Installation and Release Notes m BlackDiamond 8800 a series c series and e series modules m Summit X250e m Summit X450a and X450e series IGMP filters m Limit number of active s
140. emeXOS 12 1 4 Installation and Release Notes 2048 2048 2048 2048 2048 2048 2048 2048 New Community Format MPLS LSP as Next Hop Up 100 None Disabled 0 Disabled 0 0 No 5 ISISL2 ISISLIExt ISISL2Ext ipv4 multicast 2048 2048 2048 Shutdown Priority None None None Policy Direct Static RIP OSPFiIntra OSPFInter OSPFExt1 OSPFEXt2 ISISL1 ISISL2 ISISLIExt TISISL2Ext Advertise Inactive Routes ipv4 unicast ipv4 multicast History This command was first available in ExtremeXOS 10 1 Disabled Down Disabled Down Disabled Down Admin Operational Status Status Disabled Down Disabled Down Disabled Down Disabled Down Disabled Down Disabled Down Disabled Down Disabled Down Disabled Down Disabled Down Disabled Down Disabled Disabled 204 204 204 204 204 204 204 204 204 204 204 oo wooo wo woo oO 0 0 This command required a specific license in ExtremeXOS 11 1 Platform Availability This command is available on platforms with the appropriate license For complete information about software licensing including how to obtain and upgrade your license and what licenses are appropriate for this feature see the ExtremeXOS Concepts Guide Appendix A ExtremeXOS Software Licenses Default Route Origination and Advertisement The default route origination and advertisement feature allows you to originate and adve
141. enable or disable autonegotiation without configuring a preferred speed PD3 111344472 Security PD3 205012219 PD3 186939931 Cannot Enable DHCP using WebUI ScreenPlay allows you to configure DHCP but you cannot enable DHCP Source IP Lockdown Dynamic Deny ACL Counter Not Working Properly A source ip lockdown dynamic deny acl counter is not working properly and increments valid traffic from a trusted client Ingress Mirroring is Not Working for DHCP Snooping When Snooping is Enabled Ingress mirroring is not working for DHCP snooping when snooping is enabled on BlackDiamond 12800 series switches DHCP snooping works correctly when DHCP snooping is disabled PD3 133763260 New Backup MSM Reboots Twice after Failover A new backup MSM reboots twice after failover run MSM failover The backup MSM initially comes up correctly but is not in the In SYNC state The MSM then reboots without a core and comes up In Sync on a BlackDiamond 8800 This problem does not occur consistently and should not affect data transmission It is recommended that you disable the notify function in the disable ip security anomaly protection notify lt log cache snmp gt command to avoid potential problems PD3 96212671 DHCP Packets are Not Relayed if dhcp snooping violation action is Set to None When DHCP snooping is enabled on a port in a VLAN in monitoring only mode that is with the violation action option set to none and t
142. ending on the platform and configuration you are working with The link filter counter displayed with the detail keyword is calculated at the middle layer on receiving an event The link filter up indicates the number of link transitions from down to up at the middle layer filter Example The following command displays port system related information on a BlackDiamond 8810 switch X450a 48t 10 show port 1 info Following is sample output from this command Port Flags Link Link Num Num Num Jumbo QOS Load State ELSM UPS STP VLAN Proto Size profile Master 1 Ew e fMB ready 0 0 1 1 9194 none gt indicates Port Display Name truncated past 8 characters Flags a Load Sharing Algorithm address based D Port Disabled Extreme Discovery Protocol Enabled E Port Enabled Egress TOS Enabled j Jumbo Frame Enabled Load Sharing Enabled m MACLearning Enabled Ingress TOS Enabled o Dotlp Replacement Enabled Software redundant port Primary Software redundant port Redundant Background QOS Monitoring Enabled diffserv Replacement Enabled Vman Enabled f Unicast Flooding Enabled Multicast Flooding Enabled B Broadcast Flooding Enabled Extreme Link State Monitoring Enabled w MACLearning Disabled with Forwarding b Rx and Tx Flow Control Enabled x Rx Flow Control Enabled Rx and Tx Flow Control Disabled res oO AWE ro ExtremeXO
143. er lt meter name gt command has just been executed ExtremeXOS 12 1 4 Installation and Release Notes Table 44 Platform Specific and Feature PDs Continued SNMP PD4 888471111 The snmpMaster process experiences memory depletion while sending out AuthFailure SNMP traps Workaround Disable the AuthenTraps by setting the OID snmpEnableAuthenTraps to value 2 disabled snmpset v 2c c snmpEnableAuthenTraps 0 i 2 PD4 929531697 Performing an snmpwalk on a usmUserTag OID 1 3 6 1 4 1 99 12 35 causes the PD4 923129104 snmpMaster process to die with signal 11 Workaround Run the following command to block the access to that OID and prevent the crash configure snmpv3 add mib view defaultUserView subtree 1 3 6 1 4 1 99 12 35 type excluded Spanning Tree Protocol PD4 925787371 In RSTP when a port becomes a root port and an alternate port exists on a bridge agreement BPDUs are not immediately sent back as per standards Resolved Issues in ExtremeXOS 12 1 3 patch1 8 The following issues were resolved in ExtremeXOS 12 1 3 patch1 8 The numbers shown in column one of the following table are for internal reference and can be ignored ExtremeXOS 12 1 includes all fixes up to and including ExtremeXOS 11 1 4 4 ExtremeXOS 11 2 3 3 ExtremeXOS 11 3 4 5 ExtremeXOS 11 4 4 7 ExtremeXOS 11 5 2 10 ExtremeXOS 11 6 5 3 and ExtremeXOS 12 0 5 For information on those fixes see the release notes for the specific release Ta
144. ervice vMAN to share a port with a service VLAN the L3 multicast on the service VLAN is not forwarded by VPLS Forwarding multicast traffic from the service VLAN works correctly Counters are not getting updated on ingress and egress node transport LSPs when sending traffic by way of VPLS The counters are being updated on the transit node only This problem occurs on all three transport LSPs static RSVP and LDP PD3 192434331 Network Login PD4 780622490 The switch does not allow a user to create a static ECMP multicast route when the protocol option is included in the configure ipmroute add command An error message is displayed stating that the multicast route already exists When a MAC based network login user logs out the UPM profile configured for the user s unauthentication is not executed PD3 167032424 Policy Manager PD3 29818741 A network login authentication web session terminates after a session refresh times out when moving to a nonexistent VLAN ETHER P 8021Q is not a valid ethernet type match criteria and generates a syntax error You can use 0x8100 ExtremeXOS 12 1 4 Installation and Release Notes Table 33 Platform Specific and Feature PDs Continued PD Number Description Security PD3 75465301 The unconfigure radius command does not clear the RADIUS authentication and accounting counters SNMP PD3 204276011 An SNMP get request to query an FDB sequence number in the E
145. ess Specifies the IP address TCP Port Specifies the TCP port Default N A Usage Guidelines Use this command to remove the monitoring configuration on the ports of a health check link aggregation group Each port must be unconfigured separately specifying the IP address and TCP port Example The following command removes the configuration setting on port 12 that monitors IP address 10 1 1 3 configure sharing health check member port 12 delete track tcp 10 1 1 3 History This command was first available in ExtremeXOS 12 1 3 Platform Availability This command is available on all platforms ExtremeXOS 12 1 4 Installation and Release Notes configure sharing health check member port tcp tracking configure sharing health check member port lt port gt disable enable tcp tracking Description Enables or disables configured monitoring on a member port of a health check LAG Syntax Description port Specifies the member port Default N A Usage Guidelines This disables enables monitoring on a particular member port When monitoring is disabled the member port is added back to the LAG if it has not already been added This allows a member port to be added back to LAG even though connectivity to the host is down Example The following command disables port 12 configure sharing health check member port 12 disable tcp tracking History This command was first available in ExtremeXOS 12 1 3 Pl
146. ess interface vlanIf 1000223 slot 1 port 1 too many ACL s amp packet rate is too high and start to drop all the packets received in slow path Packets that need to be L2 switched are not egressing if the packets hit the IPv4 ACL containing a redirect action This fix requires a regular upgrade on a BlackDiamond 12804 switch It will not work if you attempt a hitless upgrade on the BlackDiamond 12804 switch When the BGP fast external failover feature is enabled BGP traps such as bgpBackwardTransition and bgpM2BackwardTransition are not generated When a shared port is configured prior to enabling an EAPS domain the EAPS protected VLAN does not block the secondary port in some cases PD4 682475164 ESRP PD4 631761683 IPv6 neighbor discovery packets sent to the CPU are affecting EAPSv2 PDUs resulting in the following message EAPS Shared Port Segment timer expired When ESRP is disabled clients using an ESRP virtual IP address as a default gateway are not able to communicate outside the VLAN ExtremeXOS 12 1 4 Installation and Release Notes Table 47 Platform Specific and Feature PDs Continued Network Login PD4 684538103 Running the save configuration command causes a memory leak in the netlogin process PD4 731628986 When rebooting a switch no local authentication takes place if the authentication order is RADIUS LOCAL and RADIUS is not reachable OSPF PD4 707855673 OSPF stops translatin
147. etwork VLAN Private VLANs maximum number of private All platforms 2 046 VLANs in an L2 only environment ExtremeXOS 12 1 4 Installation and Release Notes Metric Product Limit Provider Backbone Bridging Traffic Engineering BlackDiamond 10808 PBB TE maximum number of static MAC MSM 1 98 000 binding entries MSM 1XL 100 000 BlackDiamond 12800 series MSM 5 49 000 MSM 5R 100 000 MSM 6R 100 000 Route policies suggested maximum number of All platforms 10 000 lines in a route policy file RIP learned routes maximum number of RIP BlackDiamond 8800 series 10 000 routes supported without aggregation BlackDiamond 10808 10 000 Summit X250e 3 000 Summit X450 3 000 RIP interfaces on a single router recommended BlackDiamond 8800 series 256 maximum number of RIP routed interfaces on a 5 ata BlackDiamond 10808 384 Summit X250e 128 Summit X450 128 RIPng learned routes maximum number of BlackDiamond 8800 series 3 000 RIPng reuies BlackDiamond 10808 5 000 BlackDiamond 12800 series 5 000 Summit X250e 1 500 Summit X450 1 500 RSVP TE interfaces maximum number of BlackDiamond 10808 32 intertaces BlackDiamond 12800 R series 32 RSVP TE neighbors maximum number of BlackDiamond 10808 400 neiehborsipeginterace BlackDiamond 12800 R series 400 RSVP TE ingress LSPs maximum number of BlackDiamond 10808 2 000 ingress LSPs BlackDiamond 12800 R series 2 000 RSVP TE egress LSPs maximum number of
148. evel 1 external routes Specifies ISIS level 2 routes Specifies ISIS level 2 external routes Specifies OSPF routes Specifies OSPF externl1 routes Specifies OSPF extern2 routes Specifies OSPF inter routes Specifies OSPF intra routes Specifies RIP routes Specifies static routes The address family to which the IGP routes are exported BGP supports two address families IPv4 Unicast and IPv4 Multicast Name of policy to be associated with network export Policy can filter and or change the route parameters If no address family is specified IPv4 unicast is the default Usage Guidelines The exporting of routes between any two routing protocols is a discreet configuration function For example you must configure the switch to export routes from OSPF to BGP and if desired you must configure the switch to export routes from BGP to OSPF You must first configure both protocols and then verify the independent operation of each Then you can configure the routes to export from OSPF to BGP and the routes to export from BGP to OSPF Similarly for BGP and ISIS or BGP and RIP ExtremeXOS 12 1 4 Installation and Release Notes You can use a policy to associate BGP attributes including Community NextHop MED Origin and Local Preference with the routes A policy can also be used to filter out exported routes Using the export command to redistribute routes complements the redistribution of routes using the configure bgp add networ
149. for which an MPLS label lookup is performed are not mirrored when ingress mirroring is activated ExtremeXOS 12 1 4 Installation and Release Notes Open Issues Known Behaviors and Resolved Issues
150. g external routes after deleting a static route to the same destination IP address SNMP PD4 713364618 The extremePortVlanStatsTable definition in the EXTREME VLAN MIB does not comply with RFC 2578 VRRP PD4 799835165 System memory is depleted when non ICMP IP packets are sent to a VRRP virtual IP address PD4 629585032 VRRP backup does not return the real IP address of the VRRP master for the SNMP object vrrpOperMasterl pAddr Resolved Issues in ExtremeXOS 12 1 3 patch1 2 The following issues were resolved in ExtremeXOS 12 1 3 patch1 2 The numbers shown in column one of the following table are for internal reference and can be ignored ExtremeXOS 12 1 includes all fixes up to and including ExtremeXOS 11 1 4 4 ExtremeXOS 11 2 3 3 ExtremeXOS 11 3 4 5 ExtremeXOS 11 4 4 7 ExtremeXOS 11 5 2 10 ExtremeXOS 11 6 5 3 and ExtremeXOS 12 0 5 For information on those fixes see the release notes for the specific release Table 48 Platform Specific and Feature PDs PD Number General PD4 733283307 PD3 209497034 Description Packets ingressing a BlackDiamond 10800 or 12800 series switch with a multicast destination MAC address and a unicast destination IP address are being dropped PD4 602948121 The default value for the CPU monitoring threshold value shown in the CLI help message is different from the default value in the configuration file PD4 479342731 In some cases a redundant port does n
151. g guidelines apply to link aggregation on the Summit X250e X450a X450e and X650 series switches e One static LAG can contain up to 8 ports e An LACP LAG can include a maximum of 16 ports out of these up to 8 can be selected links and the remaining 8 will be standby links A Health Check LAG can contain up to 8 ports The maximum number of LAGs is 128 e The default load sharing algorithm is L2 address based aggregation Any broadcast multicast or unknown unicast packet is distributed across all members in the LAG e The available address based parameters on the Summit X250e X450a X450e and X650 series switches are L2 for Layer 2 and L3_L4 for Layer 3 plus Layer 4 If the packet is not IP the switch applies the Layer 2 algorithm which is the default setting e Beginning with ExtremeXOS version 12 0 the maximum number of LAGs in a SummitStack is 128 unless an original X450 series module is in use in the stack in which case the maximum number of LAGs is 32 ExtremeXOS 12 1 4 Installation and Release Notes dd note You cannot configure port based load sharing algorithm on Summit X450 series switches you configure only address based load sharing algorithms Summit X450 series switch only The following guidelines apply to link aggregation on the Summit X450 series switch e One static LAG can contain up to 8 ports e An LACP LAG can include a maximum of 16 ports out of these up to 8 can be selected links and the re
152. groups with 10G4X 32 Note The actual number of load share groups without 10G4X 128 tat cane configured i ted bythe number gisckDiamond 10808 128 SummitStack BlackDiamond 12800 series 128 Summit X150 and X350 series 32 Summit X250e 32 Summit X450 32 SummitStack with Summit X450 24t 32 with Summit X450 24x 32 without Summit X450 24t 128 without Summit X450 24x 128 Load sharing maximum number of ports per BlackDiamond 8800 series 8 lezgi shere BOHR BlackDiamond 10808 16 BlackDiamond 12800 series 16 Summit series 8 Logged messages maximum number of All platforms 20 000 messages logged locally on the system MAC based security maximum number of MAC All platforms 1 024 based security policies MAC in MAC maximum number of MAC FDB BlackDiamond 10808 100 000 a gn te focal sie and BlckDiamond 12800 sere 100 000 side MAC in MAC maximum number of regular BlackDiamond 10808 4 000 MEAN VLAN UMAN BULL BlackDiamond 12800 series 4 000 MAC in MAC maximum number of SVLANs BlackDiamond 10808 1G DRAM 2 000 BlackDiamond 12800 series 512 DRAM 2 000 Mirroring filters maximum number of All platforms 16 mirroring filters Mirroring monitor port maximum number of All platforms 1 monitor ports Mirroring one to many filters maximum All platforms 16 number of one to many mirroring filters Mirroring one to many monitor port maximum All platforms 16 number of one to many monitor ports MPLS LDP enabled interfaces m
153. hbors EBGP paths are preferred to IBGP paths The BGP ECMP feature allows you to define the maximum number of equal cost paths up to eight in a multipath A multipath for an IBGP destination is called an IBGP multipath and the multipath for an EBGP destination is called an EBGP multipath If there are more equal cost paths for a destination than the configured maximum the BGP identifier for the advertising BGP speaker is used to establish a path priority The lower BGP identifier values have priority over the higher values For example if the configuration supports 4 paths in a multipath only the four paths with the lowest BGP identifier values become part of the multipath To enable or disable BGP ECMP enter the following command configure bgp maximum paths lt max paths gt The max paths setting applies to BGP on the current VR Specify more than 1 path to enable BGP ECMP and define the maximum number of paths for IBGP and EBGP multipaths Specify 1 path to disable ECMP To display BGP ECMP configuration information use the show bgp command The following commands have been added or modified to support this feature e configure bgp maximum paths on page 20 e show bgp on page 21 e show bgp routes on page 23 ExtremeXOS 12 1 4 Installation and Release Notes configure bgp maximum paths configure bgp maximum paths lt max paths gt Description Enables or disables the BGP ECMP feature and specifies the maximum number of path
154. he switch is acting as a BOOTP relay DHCP packets are not relayed from the DHCP server on that port As a workaround the port can be configured as a trusted port trusted for DHCP server packets with DHCP snooping enabled with a violation action of drop packet instead of none This works the same as setting the violation action to none viz The DHCP bindings database is built up by monitoring DHCP traffic but no rogue DHCP server traffic on that port is dropped PD3 75120608 Unconfigure RADIUS and TACACS Does Not Reset Timeout Value to System Default The unconfigure radius and unconfigure tacacs commands do not reset the timeout value to the system default of 3 seconds PD3 74708933 RADIUS Authentication Do Not Work Correctly if Console Accesses the Backup MSM If you are configuring a BlackDiamond 10808 or BlackDiamond 8800 with RADIUS authentication when telnet or console access is through the master MSM RADIUS authentication works correctly However if console access is through the backup MSM RADIUS authentication does not work correctly and generates the following error message lt Erro AAA RADIUS serverNotInit gt MSM B Authentication server for Switch Management is not initialized ExtremeXOS 12 1 4 Installation and Release Notes Table 32 Platform Specific and Feature PDs Continued PD Number PD3 29948301 sFlow PD3 205380274 Description Changing a Password after Password Expiration Terminates SSH
155. he traffic is forwarded without applying the matched rule in the policy file PD3 118223441 PD3 57946832 PD3 26612201 PD3 24794592 Before Changing a VLAN Tag Unconfigure all ACLs Applied to the VLAN Before changing a VLAN tag make sure you unconfigure all the ACLs applied to the VLAN Also after changing the tag reconfigure the ACLs to be applied on the VLAN This applies to BlackDiamond 10808 and 12800 series switches only ExtremeXOS 12 1 4 Installation and Release Notes Table 32 Platform Specific and Feature PDs Continued PD Number PD3 127842058 PD3 127842159 Description Only Ingress Applied CLEAR Flow Rules are Triggered With CLEAR Flow enabled only ingress applied CLEAR Flow rules are triggered PD3 126824622 IPv6 Protocol ICMP Should Not be Allowed If an IPv6 address is included in a configuration use ICMPv6 for the protocol ICMP IPv4 should not be allowed PD3 77983510 Summit X450a and Summit X450e series switches and BlackDiamond 8800 a series and e series Modules Boot Time and Timing for Applying ACLs Summit X450a and Summit X450e series switches and BlackDiamond 8800 a series and e series modules provide more powerful ACL capabilities Because of this the amount and complexity of ACL rules will naturally impact the time needed to process and apply the ACL rules to the switch This will also impact switch bootup time Access Control List limitations fall into two areas phys
156. he version number of the core image and the module must match For example the module bd10k 12 1 4 ssh xmod can only be installed onto the core image bd10k 12 1 4 xos You can download and install the SSH module oO dd note You must terminate and restart the thttpd process before you can use SSL Assuming that you have an installed and running ExtremeXOS 12 1 software on the active partition follow these steps to install the module 1 Download the module image to your TFIP server Download the image you received from Extreme Networks to your TFIP server 2 Determine the active partition for your switch Run the show switch command to determine your current selected and booted image partitions The booted image partition indicates the currently active partition 3 Download and install the module image to the active partition Download the image to the switch using the download image command The filename for the only available module image is bd10k 12 1 4 ssh xmod The virtual router lt vr gt that you will use is the one that connects to your TFTP server you determined this in step 2 Verify which virtual router connects to your TFIP server in the upgrade procedure Since the system virtual router names changed from release 10 1 2 17 to 11 2 3 3 the name will be different from that used to download the initial upgrade image Use vr mgmt for this step or vr default This example assumes that you are using virtual router
157. health check System health check sys recovery level Recovery level on exception syslog Remote syslog target tacacs Configure TACACS Server tacacs accounting Configure TACACS Accounting Server telnet Telnet daemon time System time timezone Time zone trusted ports Trusted ports trusted servers Trusted servers tunnel Tunnel vlan VLAN vman vMAN configuration lt eapsDomain gt EAPS domain name lt esrpDomain gt ESRP domain name lt metername gt Meter name lt qosprofile gt QoS profile lt stpd_name gt STP domain name lt tunnel_name gt Tunnel name lt vlan_name gt VLAN name cp Copy file internal memory Location is internal storage lt old name gt Old file name create Create system configuration ExtremeXOS 12 1 4 Installation and Release Notes Table 29 Summit X150 and X350 Supported Commands Continued Command Description access list Dynamic rule account Login account eaps EAPS Ethernet Automatic Protection Switching domain fdbentry FDB entry log Configure log service meter ingress traffic metering netlogin Network login protocol Protocol qosprofile QoS Profile stpd STP domain tunnel Tunnel vlan VLAN configuration vman vMAN configuration delete Delete system configuration access list Access list account Login account eaps
158. hould not advertise a label mapping for a direct VLAN that does not have IP forwarding enabled MPLS PD3 204793983 Egress Rate Limit is Not Accurate in show port utilization Command Output The egress rate limit shown in the command output of the show port utilization command is not correct PD3 203917264 Multicast PD4 339945634 Changing Explicit Route Object of LSP Does Not Clearly Show LSP Status When an explicit route object ERO is changed for an LSP session that is up the LSP that is already up is not torn down LSP stays up based on the older values The retry count continues to increment as LSP tries to come up with new values by querying routes every 30 seconds This is done while the earlier LSP session is still active using the previously configured values See the retry count in the command output for the show mpls rsvp te lsp lt lsp_name gt detail command Packets Ingressing on a Member of a Load Sharing Group in the Mirrored VLAN Should be Mirrored When a load sharing group is a member of a mirrored VLAN packets ingressing on the member of the load sharing group in the mirrored VLAN should be mirrored On the Summit family of switches and BlackDiamond 8800 modules packets ingressing on member ports other than the master port of the load sharing group in the VLAN are not mirrored Workaround Packets ingressing non master ports in the load sharing group on the mirrored VLAN can be mirrored by adding
159. ibers traffic will not resume until the IP multicast cache is flushed and relearned PD3 208735701 Removing a PIM VLAN from a PIM domain using the configure pim delete vlan lt vlan name gt command and adding the VLAN back into the PIM domain using the configure pim add vlan lt vlan name gt sparse command does not restore traffic on a remote MSDP domain Explicitly disable PIM and enable PIM to restore traffic PD3 206283185 When PIM snooping is enabled both globally and on a VLAN disabling PIM snooping on the VLAN also disables PIM snooping globally PD3 163090651 PD3 168968151 No error messages are displayed when unconfiguring a group limit on a port that does not have a group limit configured When configuring IGMP the maximum response time can be configured to a higher time interval that the query response time without the system displaying a warning message that this is not allowed PD3 171281681 PIM Layer 3 multicast forwarding is not working properly on a private VLAN with PIM enabled in dense mode PD3 177958011 PD3 201244849 Network Login PD3 204414763 Network Services PD3 65450031 OSPF PD3 202839989 PoE PD4 283661276 SNMP PD4 264761905 PD4 217023403 A switch configured for MVR leaks multicast packets to VLANs that are not configured to receive multicast streams When a switch is up and running and all ports are in a default VLAN the switch does not forward an EAPOL fr
160. ical and virtual Physical Limits Summit X450a and Summit X450e series switches The per VLAN wildcard port any and single port access list installation limitations are 1024 rules for the Summit X450e and 2048 rules for the Summit X450a Physical Limits BlackDiamond 8800 a series and e series modules The per VLAN wildcard port any and single port access list installation limitations are 1024 rules for the e series modules and 2048 rules for the a series modules Extreme Networks recommends that you configure ACLs as per VLAN wildcard or single port If either of the following is true you will have to configure ACLs with multi port lists Your application requires that ports do not have a homogeneous ACL policy When BlackDiamond 8800 original series modules are operational in the same chassis it may be necessary to configure ACLs to specific port lists instead of as wildcard or per VLAN This is because the original series modules have smaller physical limits Virtual Limits Summit X450a and Summit X450e series switches When configuring a multi port ACL use the following guideline The total ACL count as calculated by ACL rules times ports applied to should not exceed 48 000 total ACL rules For example applying a 1 000 rule policy file to a 48 port multi port list is supported 1 000 rules 48 ports in the list lt 48 000 Virtual Limits BlackDiamond 8800 a series and e series modules When configu
161. igin After a policy is configured for default route origination BGP must periodically scan the local BGP RIB to make sure that the policy rules evaluate to true for at least one route in local BGP RIB If the rules evaluate to true default origination remains active If the rules evaluate to false then default origination becomes inactive and the default routes must be withdrawn Enabling and Disabling Route Origination To enable or disable BGP default route origination and advertisement for BGP neighbors use the following commands enable bgp neighbor lt remoteaddr gt neighbor all address family ipv4 unicast ipv4 multicast originate default policy lt policy name gt disable bgp neighbor lt remoteaddr gt neighbor all address family ipv4 unicast ipv4 multicast originate default To enable or disable BGP default route origination and advertisement for a BGP peer group use the following commands enable bgp peer group lt peer group name gt address family ipv4 unicast ipv4 multicast originate default policy lt policy name gt disable bgp peer group lt peer group name gt address family ipv4 unicast ipv4 multicast originate default Example Default Route Origination The following example configures the originate default route feature for BGP neighbor 10 203 134 5 using policy def_originate pol def_originate pol entry prefix_matching if match any niri 192 168 3 0 24 then
162. inate default disable bgp neighbor lt remoteaddr gt neighbor all address family ipv4 unicast ipv4 multicast originate default Description Removes a default route to a single BGP neighbor or to all BGP neighbors Syntax Description neighbor lt remoteaddr gt Specifies the IP address of a BGP neighbor for which the default route is removed neighbor all Specifies that default routes are to be removed for all BGP neighbors ipv4 unicast Specifies that the removed default routes apply to IPv4 unicast routes If you do not specify an address family the command applies to IPv4 unicast routes ipv4 multicast Specifies that the removed default routes apply to IPv4 multicast routes Default Disabled BGP does not automatically originate and advertise default routes to BGP neighbors Usage Guidelines This command can be successfully executed at any time irrespective of whether local BGP or the remote BGP peer is enabled or disabled Example The following command removes default routes for IPv4 unicast traffic for all BGP peer nodes disable bgp neighbor all originate default History This command was first available in ExtremeXOS 12 1 3 Platform Availability This command is available on platforms with the appropriate license For complete information about software licensing including how to obtain and upgrade your license and what licenses are appropriate for this feature see the ExtremeXOS Concepts Guide
163. including how to obtain and upgrade your license and what licenses are appropriate for this feature see the ExtremeXOS Concepts Guide Appendix A ExtremeXOS Software Licenses Blackhole Route Redistribution BGP now supports the redistribution of blackhole routes The following commands have been updated to support this feature e disable bgp export on page 28 e enable bgp export on page 30 ExtremeXOS 12 1 4 Installation and Release Notes disable bgp export disable bgp export blackhole direct isis isis level 1 isis level 1l external isis level 2 isis level 2 external ospf ospf extern1 ospf extern2 ospf inter ospf intra rip static address family ipv4 unicast ipv4 multicast Description Disables BGP from exporting routes from other protocols to BGP peers Syntax Description blackhole direct isis isis level 1 isis level 1 external isis level 2 isis level 2 external ospf ospf extern1 ospf extern2 ospf inter ospf intra rip static address family Default Disabled Specifies blackhole routes Specifies direct routes Specifies ISIS routes Specifies ISIS level 1 routes Specifies ISIS level 1 external routes Specifies ISIS level 2 routes Specifies ISIS level 2 external routes Specifies OSPF routes Specifies OSPF externl1 routes Specifies OSPF extern2 routes Specifies OSPF inter routes Specifies OSPF intra routes Specifies RIP routes Specifies
164. ing on a switch the max burst size value is not reset after reconfiguring the switch PD4 699307521 When running the show ports stack ports rxerrors command the RX Over count continuously increments even without user traffic PD4 759415981 PD4 489103037 A HAL crash occurs when both links of a stack master are disabled PD4 759590070 SummitStack PD4 623659132 ACL PD4 556797775 After running the configure sys recovery level slot 1 shutdown command the message Errors will cause Slot 1 shutdown is displayed on the console and in the system log after then running the show configuration or save configuration commands After a SummitStack failover the new master node is not reachable using an alternate IP address or gateway The show access list meter ports x command returns all meters on the switch not just the one associated with port x PD4 641467077 The telnetd process crashes with signal 11 when the same policy file is used in a telnet access profile and an ACL PD4 738207292 Access profile configurations for SNMP and SSH modules are not available in the show configuration command output PD4 667212313 PD4 757850193 PD4 569838439 BGP PD4 507188532 EAPS PD4 627092945 If the refresh policy command is invoked by adding more entries to the policy file then after unconfiguring that specific ACL an ExtremeXOS switch starts logging messages such as Denied packet on ing
165. ingress allow egress queue PD3 129177287 PD3 16578296 RMON PD3 12950492 If IRL ERL Traffic Queue Mapping Extends to all Ports Port Selection is Void Create an ingress traffic queue with allow egress shaping and create an egress traffic queue Map the IRL to ERL on all ports Send unidirectional traffic which should hit the IRL rule at ingress The same traffic is visible to the ERL at the egress port without selecting the designated port of VLAN vMAN Disabling Load Sharing or Deleting Member Ports from a Trunk The member ports of a trunk will retain the QoS profile configuration of the trunk based on the master port after load sharing is disabled or if a port is removed from the trunk clear counter Command Not Supported Issuing the clear counter command might cause a high number to be displayed in variables such as etherHistoryOctets etherHistoryPkts and etherHistoryTable ExtremeXOS 12 1 4 Installation and Release Notes Table 32 Platform Specific and Feature PDs Continued PD Number ScreenPlay PD3 204766394 Description Discrepancy Between ExtremeXOS CLI and ScreenPlay When Configuring Port Speed and Duplex Settings There is a discrepancy between the ExtremeXOS CLI and ScreenPlay when configuring port speed and duplex settings Using ExtremeXOS you can configure a preferred speed for example 1 000 and enable autonegotiation for the duplex settings Using ScreenPlay you can only
166. ip security IP Security iparp IP ARP command iproute IPROUTE HELP jumbo frame Jumbo frame learning Learning IIdp Configure LLDP specific settings log Configure log service loopback mode Loopback mac lockdown timeout MAC lockdown timeout mirroring Mirroring mid Multicast Listener Discovery Protocol mvr Multicast VLAN Registration netlogin Configure Network Login specific settings ports Port radius RADIUS client radius accounting RADIUS client accounting rmon RMON CLI command sflow Disable sFlow module sharing Sharing smartredundancy Smart redundancy on a port software redundant feature snmp Configure SNMP specific settings sntp client Enable SNTP client stpd STP domain syslog Configure syslog service tacacs TACACS Client tacacs accounting tacacs authorization ExtremeXOS 12 1 4 Installation and Release Notes TACACS Client Accounting TACACS Client CLI Authorization Table 29 Summit X150 and X350 Supported Commands Continued telnet Command Description Disable incoming telnet connections udp echo server Enable a UDP echo server vlan VLAN configuration watchdog Watchdog monitoring feature web WEB help xml cli CLl based XML configuration mode xml mode Raw XML configuration mode lt eapsDomain gt EAPS domain name lt stpd_name gt STP domain name lt vlan name gt VL
167. ipv4 multicast advertise inactive route disable bgp address family ipv4 unicast ipv4 multicast advertise inactive route When BGP inactive route advertising is enabled inactive BGP routes are considered for BGP route aggregation When this feature is disabled inactive BGP routes are ignored while aggregating routes The following commands have been added or modified to support this feature e disable bgp advertise inactive route on page 7 e enable bgp advertise inactive route on page 8 e show bgp on page 9 ExtremeXOS 12 1 4 Installation and Release Notes disable bgp advertise inactive route disable bgp address family ipv4 unicast ipv4 multicast advertise inactive route Description Disables advertisement of BGP inactive routes which are defined as those routes that rated best by BGP and not best in the IP routing table Syntax Description ipv4 unicast Disables inactive route advertisement for IPv4 unicast routes If you do not specify an address family the command applies to IPv4 unicast routes ipv4 multicast Disables inactive route advertisement for IPv4 multicast routes Default Disabled Usage Guidelines This command can be successfully executed only when BGP is globally disabled If you want to disable inactive route advertisement and BGP is enabled you must disable BGP disable bgp disable this feature and then enable BGP enable bgp Example The following command disables inactive ro
168. irroring mid Multicast Listener Discovery Protocol mvr Multicast VLAN Registration netlogin Configure Network Login specific settings ports Port radius RADIUS Client radius accounting RADIUS Client Accounting rmon RMON CLI command sflow Enable sFlow module sharing Sharing smartredundancy Smart redundancy on a port software redundant port feature snmp Configure SNMP specific settings sntp client Enable SNTP client stpd STP domain syslog Configure syslog service tacacs TACACS client tacacs accounting TACACS client accounting tacacs authorization TACACS client CLI authorization telnet Allow incoming telnet connections udp echo server Enable a UDP echo server vlan VLAN configuration watchdog Watchdog monitoring feature web WEB help xml cli CLl based XML configuration mode xml mode Raw XML configuration mode lt eapsDomain gt EAPS domain name lt stpd_name gt STP domain name lt vlan name gt VLAN name exit Exit configuration shell history Command history install Install system image bootrom Package to install ExtremeXOS 12 1 4 Installation and Release Notes Table 29 Summit X150 and X350 Supported Commands Continued Command Description image Package to install load Load system configuration script ExtremeXOS CLI script logout Exit configuration shell Is List file internal memory Interna
169. itStack IPv4 remote host cache entries are not created after a failover or if the default stack MAC address is changed manually PD4 460847031 PD4 431521921 Rebooting a non stacking Summit switch may generate the following error Slot 1 unit lt Erro HAL Port Error gt aspenCardPortLinkscanHandler 2 HiGig port 24 is not a stack port PD4 562260113 ACL PD4 438884701 BGP PD4 331422601 PD4 490592183 IGMP PD4 415829237 PD3 169760051 On a Summit X450a stack the following error message may be displayed in the logs after upgrading the stack lt Warn Kern Card Warning gt Slot 1 shid_eeprom_read line 3018 12C I O operation failed Saving a dynamic ACL fails when using the permit or deny keywords as the command action A border gateway protocol BGP route can point to the wrong next hop in a route table when a default route is also learned by way of BGP in another scenario A BGP process crash occurs when a BGP update message is received with an as path extended length flag set Sending an IGMP report on a port with an address reserved for multicast DNS causes the port to become a router port resulting in all multicast traffic being forwarded on that port in a VLAN PD4 646173339 PD4 634273041 Network Login PD4 413330044 When an ExtremeXOS switch receives bursty IP multicast traffic IGMP snooping entries for some of the multicast streams are not created Because of this those I
170. itStack the maximum number of LAGs is 128 unless a 10G4X module is in use in a BlackDiamond 8800 series switch or a Summit X450 24t or X450 24x switch is in the SummitStack in which case the maximum number of LAGs is 32 oO dd note You cannot configure more than 32 LAGs on a BlackDiamond 8800 chassis with a 10G4X module running or that has a slot configured for the 10G4X module You cannot configure more than 32 LAGs on a SummitStack that has a Summit X450 24t or X450 24x or that has a slot configured for either model If you attempt to configure more than 32 LAGs on a BlackDiamond 8800 chassis that contains an 10G4X module or has a slot configured for the 10G4X module the system displays the following error message Error Slot lt slot_number gt can support a maximum of 32 trunks ExtremeXOS 12 1 4 Installation and Release Notes If you want to configure more than 32 LAGs it is not necessary to remove the 10G4X or Summit X450 series module however you must both unconfigure the slot holding the module and disable the slot holding that module or remove the module the disable slot command is not available on SummitStack Use the following commands to unconfigure the slot and disable that slot unconfigure slot and disable slot If you attempt to insert a 10G4X module into a BlackDiamond 8800 chassis or a SummitStack with a Summit X450 series module configured for more than 32 LAGs the module fails the Init state with log er
171. ith a 10G8X module does not process client initiated address resolution protocol ARP requests If you remove and then reinsert the backup MSM after the failover the ARP requests are processed correctly Multicast manager is showing continuously increasing memory consumption PD4 449901506 Disabling multicast flooding on a port may result in ARP requests being blocked Spanning Tree Protocol PD4 453116841 Spanning Tree Protocol STP BPDUs are filtered on a per port basis instead of a per VLAN basis ExtremeXOS 12 1 4 Installation and Release Notes Resolved Issues in ExtremeXOS 12 1 2 17 patch1 7 The following issues were resolved in ExtremeXOS 12 1 2 17 patch1 7 The numbers shown in column one of the following table are for internal reference and can be ignored ExtremeXOS 12 1 includes all fixes up to and including ExtremeXOS 11 1 4 4 ExtremeXOS 11 2 3 3 ExtremeXOS 11 3 4 5 ExtremeXOS 11 4 4 7 ExtremeXOS 11 5 2 10 ExtremeXOS 11 6 4 11 through patch1 8 and ExtremeXOS 12 0 3 16 through patch1 13 For information on those fixes see the release notes for the specific release Table 54 Platform Specific and Feature PDs PD Number Description General PD4 485801147 BlackDiamond 8806 and 8810 I O modules may reset without an external trigger IGMP PD4 473100155 IP packets sent to local multicast group 224 0 0 x may occasionally be slow path forwarded even with IGMP snooping disabled Network Login PD4 4
172. k command The configure bgp add network command adds the route to BGP only if the route is present in the routing table The enable bgp export command redistributes an individual route from the routing table to BGP If you use both commands to redistribute routes the routes redistributed using the network command take precedence over routes redistributed using the export command Example The following command enables BGP to export routes from the OSPF protocol to BGP peers enable bgp export ospf History This command was first available in ExtremeXOS 10 1 This command required a specific license in ExtremeXOS 11 1 The blackhole option was added in ExtremeXOS 12 1 3 Platform Availability This command is available on platforms with the appropriate license For complete information about software licensing including how to obtain and upgrade your license and what licenses are appropriate for this feature see the ExtremeXOS Concepts Guide Appendix A ExtremeXOS Software Licenses ExtremeXOS 12 1 4 Installation and Release Notes Flow Control Summit Family of Switches and BlackDiamond 8800 Series Switches Only With autonegotiation enabled the Summit family of switches and the BlackDiamond 8800 series switches advertise the ability to support pause frames This includes receiving reacting to stopping transmission and transmitting pause frames However the switch does not actually transmit pause frames unless it i
173. kDiamond 8800 series 100 ee number of routers in a single OSPF BlackDiamond 10808 200 BlackDiamond 12800 series 100 Summit X250e 50 Summit X450 50 OSPF subnets on a single router recommended All platforms with Core license or above 400 maximum number of OSPF routed subnets on a switch OSPF virtual links maximum number of All platforms with Core license or above 32 supported OSPF virtual links OSPFv3 areas as an ABR the maximum All platforms with Core license or above 16 number of supported OSPFv3 areas OSPFv3 interfaces maximum number of BlackDiamond 8800 series 256 Spi SULT BlackDiamond 10808 384 BlackDiamond 12800 series 256 Summit X450 128 Summit X450a 128 OSPFv3 neighbors maximum number of BlackDiamond 8800 series 64 OSPR mele Dats BlackDiamond 10808 128 BlackDiamond 12800 series 128 Summit X450 64 Summit X450a 64 OSPFv3 virtual links maximum number of All platforms with Core license or above 16 OSPFv3 virtual links supported OSPFv3 external routes recommended BlackDiamond 8800 series 10 000 maximum number of external routes BlackDiamond 10808 60 000 BlackDiamond 12800 series 50 000 Summit X450 10 000 Summit X450a 10 000 ExtremeXOS 12 1 4 Installation and Release Notes Metric Product Limit OSPFv3 inter or intra area routes recommended BlackDiamond 8800 series 6 000 maximum number of inter or intra area routes BlackDiamond 10808 6 000 BlackDiamond 12800 series 6 000
174. l CF mv Rename file internal memory Location is internal storage lt old name gt Old file name nslookup lt host name or ip gt Get IP address of host Host name or IP address ping Ping an IP address continuous Ping the specified host until stopped count Number of ping requests to send dont fragment Set the IP do not fragment bit interval Time interval between sending out ping request ipv4 Force use of IPv4 transport ipv6 Force use of IPv6 transport start size Start size of the ping packets to send tos Set the TOS value ttl Set the TTL value udp Use an UDP ping instead of ICMP ping vr Ping from specified virtual router lt host gt Host to ping quit Exit configuration shell reboot Reboot system cancel Cancel scheduled reboot time Scheduled reboot refresh Refresh system configuration policy Policy reset Reset inline power Inline power restart Restart device ports Ports process Process rm Remove file internal memory File from internal storage lt file name gt rtlookup Name of the file to delete Look up route to an IP address lt ipaddress gt lt ipv6address gt Destination address Destination address ExtremeXOS 12 1 4 Installation and Release Notes Table 29 Summit X150 and X350 Supported Commands Continued Command Description run Start new process diagnostics Perform diagnostics test
175. l each type of BootROM or firmware New PSU controller firmware is used immediately after it is installed without rebooting the switch The new BootROM and firmware overwrite the older versions stored in FLASH memory BD 8806 2 install firmware Installing version 1 0 1 11 of the MSM bootrom s Do you want to continue y yes n no lt cr gt cancel Yes Do you want to save configuration changes to primary cfg y or n Yes Saving configuration on primary MSM done Installing version 1 0 1 11 of the IO module bootrom s Do you want to continue y yes n no lt cr gt cancel Yes Installing version 2 13 of the PSU control module firmware Do you want to continue y yes n no lt cr gt cancel Yes Installing bootrom MSM bootrom s installed successfully MSM bootrom s will be activated upon next MSM reboot Installing bootrom b b IO module bootrom s installed successfully IO module bootrom s will be activated upon next IO module reboot Installing firmware PSU controller firmware installed successfully BD 8806 3 11 Upgrade the BootROM and PSU controller firmware BlackDiamond 12804 family of switches only oO dd NOTE BootROMs installed by Manufacturing should never be forced to an earlier BootROM version unless explicitly instructed by Extreme Networks support Extreme Networks requires that you upgrade the MSMs I O modules and PSU controllers in the BlackDiamond 1
176. le in the show port x y information detail and show port x y configuration command output XFP Module Support XFP modules supported on the BlackDiamond 8800 series of switches with ExtremeXOS 12 1 the minimum ExtremeXOS version required include ExtremeXOS 12 1 4 Installation and Release Notes Table 26 BlackDiamond 8800 Series of Switches XFP Support XFP Module ExtremeXOS Required SR 11 6 1 9 LR 11 6 1 9 ER 12 0 2 25 DWDM 12 1 2 17 ZR 2M 2 177 XFP modules supported on the Summit X450a and X450e series switch with ExtremeXOS 12 1 the minimum ExtremeXOS version required and the manufacturers supported include Table 27 Summit X450a and X450e Series Switch XFP Support XFP Module ExtremeXOS Required SR 11 5 1 4 LR 11 5 1 4 ER 12 0 2 25 DWDM 1S2 ZR 12m2 XFP modules supported on the Summit X350 switch with ExtremeXOS 12 1 the minimum ExtremeXOS version required and the manufacturers supported include Table 28 Summit X350 Switch XFP Support XFP Module ExtremeXOS Required SR 12 0 3 16 LR 12 0 3 16 ER 12 0 3 16 DWDM 12 1 2 17 ZR 12217 Summit X150 and X350 Series Switch Software Details The Summit X150 and X350 series switches have a reduced feature set as compared to the Summit X250 series switches Summit X150 series switches are supported from ExtremeXOS 12 0 2 25 release onwards and Summit X350 series switches are supported fro
177. lines None Example The following command displays BGP configuration information show bgp Enabled RouterId LocalPref Always Compare MED Route Reflector IGP Synchronization Routes from EBGP Routes redistributed Fast Ext Fallover ConfedId Confed Peers Yes 10 203 134 73 100 Disabled No Disabled 2 0 Disabled 0 Operational Status Shut Prio OperStatus As MED Aggregation RR ClusterId Routes from IBGP Out Updates queued Maximum ECMP Paths down rity Policy Networks Aggregate Networks Redistribute ipv4 Admin unicast Status Direct Disabled Static Disabled RIP Disabled OSPFIntra Disabled OSPFInter Disabled OSPFExt1 Disabled OSPFExt2 Disabled ISISL1 Disabled ExtremeXOS 12 1 4 Installation and Release Notes 2048 2048 2048 2048 2048 2048 2048 2048 New Community Format MPLS LSP as Next Hop Up 100 None Disabled 0 Disabled 0 0 No 5 ISISL2 ISISLIExt ISISL2Ext ipv4 multicast 2048 2048 2048 Shutdown Priority None None None Policy Direct Static RIP OSPFiIntra OSPFInter OSPFExt1 OSPFEXt2 ISISL1 ISISL2 ISISLIExt TISISL2Ext Advertise Inactive Routes ipv4 unicast ipv4 multicast History This command was first available in ExtremeXOS 10 1 Disabled Down Disabled Down Disabled Down Admin Operational Status Status Disabled Down Disabled Down Disable
178. llowing are the feature enhancements supported in ExtremeXOS 12 1 3 These features will be documented in detail in the ExtremeXOS 12 3 versions of the ExtremeXOS Concepts Guide and the ExtremeXOS Command Reference Guide unless otherwise noted BGP Enhancements The following new BGP features have been added in this release e Inactive Route Advertisement on page 6 e Default Route Origination and Advertisement on page 10 ExtremeXOS 12 1 4 Installation and Release Notes e BGP ECMP on page 19 e Support for Overlapping Aggregate Routes on page 25 e Blackhole Route Redistribution on page 27 Inactive Route Advertisement BGP inactive routes are defined as those routes that are rated best by BGP and not best in IP routing table For example an IGP route to the same destination may be best because it has a higher priority in the IP route table than the BGP best route The default configuration of the ExtremeXOS software does not advertise BGP inactive routes to BGP neighbors The default configuration no BGP inactive route advertisement is more consistent with data traffic forwarding However when advertisement of inactive BGP routes is enabled BGP need not depend upon the route manager module to know whether a BGP route is active or not This actually improves the performance of BGP processing and advertisement To enable or disable BGP inactive route advertising use the following commands enable bgp address family ipv4 unicast
179. m ExtremeXOS 12 0 3 onwards They support L2 Edge license and cannot be upgraded to higher license levels For more details on licensing see Appendix A ExtremeXOS Software Licenses in the ExtremeXOS Concepts Guide ExtremeXOS 12 1 4 Installation and Release Notes ExtremeXOS Command Line Support The following is true for all Summit X150 and X350 series switches e Summit X150 and X350 series switches do not support L3 functionality this platform does not support CLI commands for L3 functionality e Summit X150 and X350 series switches do not support stacking all CLI commands for stacking are not supported on this platform e Summit X150 and X350 series switches do not support IP forwarding however CLI commands that configure IP addresses function in order to access the management functionality of the switch are supported e Upgrade or trial licensing is not available on the Summit X150 and X350 series switches Supported Commands on the Summit X150 and X350 Series Switches Table 29 contains the list of CLI commands supported on the Summit X150 and X350 series switches Table 29 Summit X150 and X350 Supported Commands Command Description check Check policy syntax policy Policy clear Clear system configuration access list Access list account Login account counters Statistics cpu monitoring CPU utilization debug Debug command eaps EAPS Ethernet
180. maining 8 will be standby links A Health Check LAG can contain up to 8 ports The maximum number of LAGs is 32 The default load sharing algorithm is L2 address based aggregation Any broadcast multicast or unknown unicast packet is transmitted on a single port in the LAG e The available address based parameters on the Summit X450 series switch are L2 for Layer 2 and L3 for Layer 3 If the packet is not IP the switch applies the Layer 2 algorithm which is the default setting e dd note You cannot configure port based load sharing algorithm on the Summit X450 series switch you configure only address based load sharing algorithms BlackDiamond 8800 series switch only The following guidelines apply to link aggregation on the BlackDiamond 8800 series switch e A static LAG can include a maximum of 8 ports e An LACP LAG can include a maximum of 16 ports out of these up to 8 can be selected links and the remaining 8 will be standby links e A Health Check LAG can include a maximum of 8 ports Oo dd note You cannot configure port based load sharing algorithm on the BlackDiamond 8800 series switch and the Summit X450 series switches you configure only address based load sharing algorithms e The available address based parameters on the BlackDiamond 8800 series switch are L2 for Layer 2 and L3 for Layer 3 If the packet is not IP the switch applies the Layer 2 algorithm which is the default setting Beginning with
181. mit X150 24p summitX 12 1 4 2 patch1 8 xos 12 0 2 25 WOA Summit X350 24t summitX 12 1 4 2 patch1 8 xos 12 0 3 16 ROSAN Summit X350 48t summitX 12 1 4 2 patch1 8 xos 12 0 3 16 ROSA Summit X250e Component Support Summit X250e components supported with ExtremeXOS 12 1 and the minimum BootROM version required by the chassis to support each component include ExtremeXOS 12 1 4 Installation and Release Notes Table 6 Summit X250e Component Support Minimum ExtremeX0S Minimum BootROM Summit X250 Components ExtremeXOS Filenames Required Version Summit X250e 24p summitX 12 1 4 2 patch1 8 xos 12 0 1 11 Summit X250e 48p summitX 12 1 4 2 patch1 8 xos 12 0 1 11 1 0 3 0 Summit X250e 24t summitX 12 1 4 2 patch1 8 xos 12 0 1 11 1 0 3 0 Summit X250e 48t summitX 12 1 4 2 patch1 8 xos 12 0 1 11 1 0 3 0 Summit X250e 24x summitX 12 1 4 2 patch1 8 xos 12 0 2 25 ROA Summit X250e 24tDC summitX 12 1 4 2 patch1 8 xos 12 0 3 16 OSAN Summit X250e 24xDC summitX 12 1 4 2 patch1 8 xos 12 0 3 16 IOSA Summit X250e 48tDC summitX 12 1 4 2 patch1 8 xos 12 0 3 16 EOFS ml Summit X450 Component Support Summit X450 components supported with ExtremeXOS 12 1 and the minimum BootROM version required by the chassis to support each component include Table 7 Summit X450 Component Support Minimum ExtremeX0S Minimum BootROM Summit X450 Components ExtremeXOS Filenames Required Version
182. mmand Example The following command enables FEFI on port 1 configure ports 1 far end fault indication on History This command was first available in ExtremeXOS 12 1 3 Platform Availability This command is available on the Summit X450 24x and X450a 24x platforms ExtremeXOS 12 1 4 Installation and Release Notes New Features or Feature Enhancements in ExtremeXOS 12 1 2 17 Following are the new features or feature enhancements supported in ExtremeXOS 12 1 2 17 These features are documented in detail in the ExtremeXOS 12 1 2 versions of the ExtremeXOS Concepts Guide and the ExtremeXOS Command Reference Guide unless otherwise noted Connectivity Fault Management CFM is now available on SummitStack and BlackDiamond 8800 series switches EAPS updates to support multicast The following commands have been added to provide control of rapid multicast convergence after EAPS topology changes m configure eaps multicast add ring ports on off m configure eaps multicast send igmp query on off m configure eaps multicast temporary flooding on off E configure eaps multicast temporary flooding duration lt seconds gt See the ExtremeXOS Command Reference Software Version 12 1 2 for further details The show eaps command has been modified to display the configuration of these controls and the EAPS chapter in the Concepts guide has been restructured IS IS SNMP support 802 1Q Limitation on BlackDiamond 10808 and 12
183. mmand does not display the configured sFlow agent IP address netTools memory utilization increases if the switch is not able to resolve the server IP address for SNTP Spanning Tree Protocol PD4 717148940 VRRP PD4 713872530 PD4 550811211 Intermittent traffic loss is seen in PVST configurations With VRRP is enabled on a network VLAN packets received on subscriber VLANs destined for a VRRP virtual MAC are not getting L3 switched PD4 630233727 Configuring VRID authentication using the configure vrrp vlan vrid authentication simplepassword command displays the simplepassword incorrectly in the output of the show configuration command PD4 594515501 When enabling VRRP on a superVLAN within a VLAN aggregation traffic received on the subVLAN destined for the virtual IP MAC address is not getting forwarded through the superVLAN Instead the traffic is flooded out the subVLAN ports ExtremeXOS 12 1 4 Installation and Release Notes Resolved Issues in ExtremeXOS 12 1 3 The following issues were resolved in ExtremeXOS 12 1 3 The numbers shown in column one of the following table are for internal reference and can be ignored ExtremeXOS 12 1 3 includes all fixes up to and including ExtremeXOS 11 1 4 4 ExtremeXOS 11 2 3 3 ExtremeXOS 11 3 4 5 ExtremeXOS 11 4 4 7 ExtremeXOS 11 5 2 10 ExtremeXOS 11 6 5 3 and ExtremeXOS 12 0 5 For information on those fixes see the release notes for the specific release
184. multiple spanning tree instance MSTI level when edge safeguard is enabled ssh xmod must be installed to configure SSL certificates If ssh xmod is not installed on the switch configured SSL certificates are not loaded into the switch and no error is returned PD3 29034131 Stacking PD3 126815409 Rate Limiting PD4 291186891 PD4 306886471 Wireless PD3 205447934 Saving an SSL configuration causes temporary high CPU utilization The configure sys recovery level slot command does not currently work on stack slots Beginning with ExtremeXOS 12 1 or later traffic reaching the egress rate limiting queue may be dropped Enabling ip security anomaly protection with the I4port option which is also included in the default options when no option is specified prevents a wireless AP from being registered with Summit WM controllers Resolved Issues in ExtremeXOS 12 1 1 4 The following issues were resolved in ExtremeXOS 12 1 1 4 The numbers shown in column one of the following table are for internal reference and can be ignored ExtremeXOS 12 1 includes all fixes up to and including ExtremeXOS 11 1 4 4 ExtremeXOS 11 2 3 3 ExtremeXOS 11 3 4 5 ExtremeXOS 11 4 4 7 ExtremeXOS 11 5 2 10 ExtremeXOS 11 6 4 11 through patch1 8 and ExtremeXOS 12 0 3 16 For information on those fixes see the release notes for the specific release Table 58 Platform Specific and Feature PDs PD Number Description General PD3 187495081
185. n Displays detailed system related information Syntax Description mgmt Specifies the management port port_list Specifies one or more ports of slots and ports detail Specifies detailed port information Default N A Usage Guidelines This command displays information including the following e Port number e Port configuration m Virtual router Type of port Admin state Link state and speed Link counter VLAN configuration STP configuration Trunking or load sharing EDP ELSM disabled or if enabled the ELSM link state is shown as well Load balancing Learning Egress flooding Jumbo frames Link port up down traps QoS profiles vMAN status Smart Redundancy status SRP status ExtremeXOS 12 1 4 Installation and Release Notes m Additional platform specific information m LW XENPAK WAN PHY ports BlackDiamond 10808 switch and Summit X450a series switch only Framing Clocking Trace section Trace path If you do not specify a port number or range of ports detailed system related information is displayed for all ports The data is displayed in a table format This status information may be useful for your technical support representative if you have a network problem The detail parameter is used to provided more specific port information The data is called out with written explanations versus displayed in a table format Oo dd note The keyword detail displays slightly different information dep
186. nation Enabled Ingress 802 1p Inner Exam Disabled Egress IPTOS Replacement Disabled Egress 802 1p Replacement Disabled NetLogin Enabled NetLogin authentication mode MAC based NetLogin port mode MAC based VLANs Smart redundancy Enabled Software redundant port Disabled autopolarity Enabled ExtremeXOS 12 1 4 Installation and Release Notes BlackDiamond 10808 BlackDiamond 12800 and BlackDiamond 20808 series switches only The following command displays more specific information for slot 1 port 1 on a BlackDiamond 10808 switch show ports 1 1 information detail Following is sample output from this command Port ist Virtual router VR Default Type UTP Random Early drop Unsupported Admin state Enabled with auto speed sensing 100M Advertised auto duplex half duplex Advertised Link State Active 100Mbps full duplex Link Counter Up 1 time s VLAN cfg Name peggy Internal Tag 4094 MAC limit No limit STP cfg Protocol Name peggy Protocol ANY Match all protocols Trunking Load sharing is not enabled EDP Enabled ELSM Disabled Learning Enabled Unicast Flooding Enabled Multicast Flooding Enabled Broadcast Flooding Enabled Jumbo Disabled Link up down SNMP trap filter setting Enabled QoS Profile None configured Aggregate Queue QPO MinBw 0 PR 100K Pri 8 Queue QP1 MinBw 0 MaxBw 100 Pri 1 QP2 MinBw 0 MaxBw 100 Pri 2 QP3 MinBw 0 MaxBw 10
187. nd 8800 a sere 2 000 LPM routes present For BlackDiamond 8800 BlackDiamond 8800 e series 1 0009 and Summit a a a 8800 origina 2 0008 BlackDiamond 10808 224 000 BlackDiamond 12800 series 49 000 BlackDiamond 12800 R series 224 000 Summit X250e 1 0004 Summit X450 2 0009 Summit X450a 8 000 Summit X450e 1 0009 IPv4 ARP entries in hardware with maximum LPM BlackDiamond 8800 c series 6 0009 maa recommended mOr y BlackDiamond 8800 a series 2 000 LPM routes present For BlackDiamond 8800 BlackDiamond 8800 e series 5009 and Summit series gaumes number ot IP BiackDiamond 8800 originai 2 000 BlackDiamond 10808 224 000 BlackDiamond 12800 series 49 000 BlackDiamond 12800 R series 224 000 Summit X250e 500d Summit X450 2 0004 Summit X450a 2 0009 Summit X450e 5009 ExtremeXOS 12 1 4 Installation and Release Notes Metric Product Limit IPv4 remote hosts in hardware with zero LPM BlackDiamond 8800 c series 18 0004 ous _manimur recommended numba a BlackDiamond 8800 a series 14 000 gateway in hardware when LPM routing is not BlackDiamond 8800 e series 1 000 usd Foy BlackDiamond BE00 and Summit BiackDiamond 8800 originai wa entries is O and number of IPv4 ARP entries BlackDiamond 10808 N A present is 100 cr less BlackDiamond 12800 series N A BlackDiamond 12800 R series N A Summit X250e 1 0009 Summit X450 N A Summit X450a 14 0009 Summit X450e 1 0009 IPv6 host entries in hardware maximum number BlackDiamond 8800 c serie
188. nd advertisement of default routes for IPv4 unicast traffic for all nodes in the test BGP peer group enable bgp peer group test originate default History This command was first available in ExtremeXOS 12 1 3 ExtremeXOS 12 1 4 Installation and Release Notes Platform Availability This command is available on platforms with the appropriate license For complete information about software licensing including how to obtain and upgrade your license and what licenses are appropriate for this feature see the ExtremeXOS Concepts Guide Appendix A ExtremeXOS Software Licenses ExtremeXOS 12 1 4 Installation and Release Notes BGP ECMP The BGP Equal Cost Multi path ECMP feature supports load sharing by creating a multipath to a destination This multipath contains multiple routes that are determined to have an equal cost because the following parameters are the same for each route Weight Local preference for IBGP multipaths AS path entire attribute not just the length Origin code Multi Exit Discriminator MED IGP distance to the next hop Source session EBGP or IBGP dd note ECMP does not install an additional path if the next hop is the same as that of the best path All paths within a multipath must have a unique next hop value BGP ECMP does not affect the best path selection For example the router continues to designate one of the paths as the best path and advertise this best path to its neig
189. nformation that a BGP speaker must store and exchange with other BGP speakers Reducing the information that is stored and exchanged also reduces the size of the routing table Before you can create an aggregate route you must enable BGP aggregation using the following command enable bgp aggregation BGP supports overlapping routes For example you can configure both of the following aggregate addresses e 192 0 0 0 8 e 192 168 0 0 16 After you create an aggregate route the aggregate route remains inactive until BGP receives a route with an IP address and mask that conforms to an aggregate route When a conforming route is received the aggregate route becomes active and is advertised to BGP neighbors If the summary only option is specified only the aggregate route becomes active and is advertised If the summary only option is omitted any conforming aggregate routes and the received route are advertised to BGP neighbors ExtremeXOS 12 1 4 Installation and Release Notes Example The following command configures a BGP aggregate route configure bgp add aggregate address 192 1 1 4 30 History This command was first available in ExtremeXOS 10 1 This command required a specific license in ExtremeXOS 11 1 Support for overlapping aggregate addresses was added in ExtremeXOS 12 1 3 Platform Availability This command is available on platforms with the appropriate license For complete information about software licensing
190. nk Status Monitoring esrp ESRP Extreme Standby Router Protocol failsafe account Configure the failsafe account fdb FDB forwarding Configure settings for hardware forwarding idletimeout Timeout for idling configuration session igmp IGMP inline power Inline power ip mtu IP MTU Maximum Transmission Unit ip security IP security iparp IP ARP command jumbo frame size Jumbo frame size lacp LACP Link Aggregation Control Protocol IIdp Configure LLDP specific settings log Configure log service mac lockdown timeout MAC lockdown timeout meter Ingress traffic metering mirroring Mirroring mid MLDP Multicast Listener Discovery Protocol mstp MSTP configuration ExtremeXOS 12 1 4 Installation and Release Notes Table 29 Summit X150 and X350 Supported Commands Continued Command mvr Description Multicast VLAN registration neighbor discovery IPv6 neighbor netlogin Configure network login specific settings ports Ports protocol Protocol filter qosprofile QoS profile qosscheduler Set the QOS scheduling algorithm radius Configure RADIUS server radius accounting Configure RADIUS accounting server safe default script Safe default script configuration sflow Disable sFLOW module sharing Sharing snmp SNMP help snmpv3 Configure SNMPv3 sntp client Configure SNTP Client ssl SSL stpd STP domain sys
191. o fragmented packets PD4 519335296 BGP PD4 483670239 DHCP PD4 252386438 ESRP PD4 295424750 SNMP PD4 589725036 PD4 526154842 When hot swapping an I O module a DiffServ configuration does not take affect The character is not working as a regex match condition when used in the show bgp routes as path command A DHCP decline message is not forwarded when IP security is enabled with DHCP snooping Running ESRP on two switches causes the ESRP domain on one switch to remain in a pre master state and the neighboring switch to become the master This issue is seen when active ports are increased on both the master and slave switches at the same time SNMP Get for ipRouteTable OID 1 3 6 1 2 1 4 21 takes hours to complete when a switch has approximately 260 000 IP routes Spanning Tree Protocol PD4 603988151 PD4 587670304 An MSTP revision level cannot be set to a value outside the range O to 3 The MSTP revision level can now be set to any value between O and 65535 The STP process crashes when changing a link type from edge to other types ExtremeXOS 12 1 4 Installation and Release Notes Table 51 Platform Specific and Feature PDs Continued PD4 597477613 A link flap of an edge safeguard enabled port causes a switch to generate a Topology PD4 597296541 Change STP BPDU even if the attached device is not STP compatible PD4 572877743 The ExtremeXOS implementation of the Multiple Sp
192. of the following table are for internal reference and can be ignored ExtremeXOS 12 1 includes all fixes up to and including ExtremeXOS 11 1 4 4 ExtremeXOS 11 2 3 3 ExtremeXOS 11 3 4 5 ExtremeXOS 11 4 4 7 ExtremeXOS 11 5 2 10 ExtremeXOS 11 6 5 3 patch1 5 and ExtremeXOS 12 0 5 For information on those fixes see the release notes for the specific release Table 42 Platform Specific and Feature PDs PD Number General PD4 1012121678 PD4 983772991 Description The ifMauDefaultType MIB is populated with the wrong value when a switch is running ExtremeXOS 12 3 3 software PD4 901961135 When an SNTP client is configured the following log message is displayed every 4 096 seconds 10 101 1 97 lt 189 gt Aug 18 18 31 44 DM Setting hwclock time to system time and broadcasting time Tue Aug 18 19 40 00 2009 10 101 1 97 lt 189 gt Aug 18 19 40 00 DM Setting hwclock time to system time and broadcasting time Tue Aug 18 20 48 16 2009 10 101 1 97 lt 189 gt Aug 18 20 48 16 DM Setting hwclock time to system time and broadcasting time Tue Aug 18 21 56 32 2009 PD4 1013258326 An FDB refresh fails on a port when there is active traffic and a link flap on another port on the switch PD4 1007713804 Disabling learning on a VLAN or creating a remote mirroring VLAN causes excessive flooding PD4 1056306414 PD4 679109661 The LLDP process may crash with signal 11 when using the configure Ildp port ALL ad
193. ogin specific settings ports Port qosprofile QoS profile ExtremeXOS 12 1 4 Installation and Release Notes Table 29 Summit X150 and X350 Supported Commands Continued Command radius Description Unconfigure RADIUS server radius accounting Unconfigure RADIUS accounting server sflow Unconfigure sFlow port sntp client Unconfigure SNTP client stpd STP domain switch Switch configuration tacacs Unconfigure TACACS server tacacs accounting Unconfigure TACACS accounting server trusted ports Trusted ports tunnel Tunnel vlan VLAN vman vMAN lt eapsDomain gt EAPS domain name lt stpd_name gt lt tunnel_name gt STP domain name Tunnel name lt vlan_name gt VLAN name uninstall Uninstall system image image Package to uninstall upload Upload system configuration configuration System configuration debug Transfer support debug data out of the switch log Show information related to logging use Select system configuration configuration System configuration image Package to run Invoke ExtremeXOS CLI editor lt filename gt ExtremeXOS CLI file name Unsupported Commands on the Summit X150 and X350 Series Switches Following is the list of processes that are not supported with an L2 Edge license bgp msdp ospf ospfv3 rip ripng pim ExtremeXOS 12 1 4 Installation and Release Notes e virp e brm e upm
194. on the BlackDiamond 8800 series of switches when installing the ExtremeXOS image If you answer y for yes after the prompt and install the image after downloading you will also be prompted to install the new BootROM during the installation process before the switch reboots 8 Save the configuration for the new image Even though your configuration was saved before you rebooted you will need to save the configuration with the new image If you wait to login for some time after the reboot you will receive a notice that recommends that you save the configuration If you login soon after the reboot you will not receive the notice although an asterisk will appear before the command prompt indicating that the current configuration is not saved In either case save the configuration with the command save configuration 9 Upgrade the BootROM BlackDiamond 10808 switch only Extreme Networks recommends that you upgrade to the latest BootROM for the BlackDiamond 10808 While not strictly required for this release it is highly recommended Run the show version command to verify the BootROM version currently running on your switch If you are not running BootROM version 1 0 1 5 or later upgrade the BootROM using the following command download bootrom 192 168 0 12 bd10k 1 0 1 5 bootrom xbr This example assumes that you will use the same TFIP server and virtual router as in step 6 above You will be asked if you want to install the Boo
195. ons are edited and but only one session is saved BlackDiamond 8800 Series Switch PD4 1014993561 PD4 690502742 Inserting I O Module in Slot B Generates an Error The following error is displayed when inserting an I O module into slot B in a supported environment lt Erro Kern Erro r gt MSM A ahd Error reading io expander for slot 12 re 1 This message is seen only when an I O module is in use in slot B It is logged when an I O module is inserted in slot B or when the chassis boots with an I O module in slot B Having an I O module in slot B is supported while using any MSM other than MSM 128 This log message can be ignored as there is no impact to system functionality or performance BlackDiamond 10808 Switch PD3 124124316 Unicast Routes with ECMP Enabled Causes Log Errors The following error messages are shown in the log when running 50 000 unicast routes with ECMP enabled 02 05 2007 15 38 37 89 lt Warn HAL Sys Warning gt MSM A hal Reached maximum otp index allocation 02 05 2007 15 38 37 56 lt Warn HAL Sys Warning gt MSM A Previous message repeated 999 additional times in the last 1 second s PD3 68165111 System Health Check Parity Walk Verification Function Should be Enabled Various memory locations that are part of the forwarding and routing tables are parity protected on BlackDiamond 10808 switches The functionality should be turned on so that faults are detectable PD3 41204902
196. or later If a hitless upgrade is required you must globally disable network login and re enable it when the upgrade is complete dd note See the Hitless Upgrade Caveats for BlackDiamond 8800 Series Switches Only in the ExtremeXOS Concepts Guide for an important caution about performing an MSM failover ExtremeXOS 12 1 4 Installation and Release Notes oO dd note Beginning with ExtremeXOS 12 1 an ExtremeXOS core image xos file must be downloaded and installed on the alternate non active partition If you try to download to an active partition the error message Error Image can only be installed to the non active partition is displayed An ExtremeXOS modular software package xmod file can still be downloaded and installed on either the active or alternate partition oO dd note With ExtremeXOS 12 1 3 the BlackDiamond 8800 series switches and the BlackDiamond 12800 series switches now require a firmware upgrade along with the standard software upgrade dd NOTE A Failed to install image error occurs when trying to upgrade from ExtremeXOS 11 2 1 images to ExtremeXOS 11 6 or later To upgrade to ExtremeXOS 12 1 you must currently be running ExtremeXOS 11 6 or later If you are not running 11 6 or later you must first upgrade to ExtremeXOS 11 6 and then upgrade to ExtremeXOS 12 1 Quick Summary To install and upgrade to ExtremeXOS 12 1 on your system you will be following these steps Do
197. orrectly PD3 27536111 BGP PD4 1243359825 PD4 1185696661 CLEAR Flow PD3 16311713 Control Protocols PD3 160517465 EAPS PD4 716385097 When you edit tcpDestPort pol using the VI editor and save it with a different filename the new file is not applied A BGP process crash with signal 11 occurs when disabling and enabling a BGP peer with 15 000 routes A syntax error is not displayed when a policy file is configured using CLEAR Flow rules on BlackDiamond 8800 BlackDiamond 8806 and Summit X450 switches The rule is silently ignored Configuring EAPS and MSTP on the same port for the same VLAN results in a longer convergence time for the EAPS topology change Even after a RxPduRingUpFlush is triggered for the topology change the FDB entry is cleared An EAPS controller goes into a blocking state even when a ring is not complete ExtremeXOS 12 1 4 Installation and Release Notes Table 33 Platform Specific and Feature PDs Continued PD Number IP Routing Products PD3 188555286 Description Not all shared static IP routes may be utilized following a link flap to one or more gateways used by those static routes For better resiliency when sharing static routes configure static ARP and FDB entries for each gateway used by the shared static routes To do this run the following commands for each gateway configure iparp add lt ip_addr gt vr lt vr_name gt lt mac gt create fdbentry lt mac_addr gt
198. ot go down even though the primary port is up PD4 707271073 PD4 615043961 When uninstalling an SSH image the message This image will be used only after rebooting the switch is displayed PD4 732618403 PD4 490976302 The CLI command show vlan lt vlan name gt security does not display output if the VLAN name contains 32 characters PD4 732618428 PD4 520283119 The CLI command configure iparp add proxy allows an IP address of 0 0 0 0 to be configured PD4 728458098 PD4 491202062 Routing protocols such as RIP VRRP and PIM cannot be configured on a VLAN if the name of the VLAN contains 32 characters PD4 671782473 A PIM process crash with signal 11 occurs when receiving a PIM state refresh packet of type 9 PD4 496712328 The ExtremeXOS CLI does not display an error message when a user tries to apply a VMAN policy file to an entire vMAN ExtremeXOS 12 1 4 Installation and Release Notes Table 48 Platform Specific and Feature PDs Continued PD4 625406003 PD4 612637671 Process thttpd might die with signal 6 on a switch monitored by EPICenter ScreenPlay PD4 731748056 PD3 203116541 The following EEPROM checksum failed error messages may be seen in the syslog MSM B card eeprom checksum failed Oxb8a 0xb89 MSM A card eeprom checksum failed Oxb66 0xb65 Backplane eeprom checksum failed Oxd71 Oxcd5 PD4 731748090 PD4 623659557 BlackDiamond 88 PD4 702735770
199. r Description General PD4 386193795 To avoid false warnings such as lt Warn HAL IPv4Adj RmtHostL3TblFull gt MSM A PD4 379068411 IPv4 unicast remote host entry not added Hardware L3 Table full from appearing in the log the following changes have been implemented e Avoid a timing window where a new route is learned around the same time a new remote host is sampled e Do not perform remote host sampling on packets sent to the CPU for L2 software learning such as MAC limit learning or packets whose source MAC is not that of the switch e Prevent warning messages for duplicate add of an existing remote host PD4 389339527 A netTools process crash occurs when processing incoming BOOTP Reply when User Datagram Protocol UDP forwarding is enabled BlackDiamond 8800 Series Switch PD4 354784718 On a BlackDiamond 8800 series switch the following error appears in the syslog prior to seeing a hal crash on the switch MSM A Unknown cardtype in slot 9 please program the eeprom MSM A ahd_eeprom_read Error reading eeprom for slot 9 at offset 0 ACL PD4 362643617 Refreshing an egress vMAN translation ACL with the keyword deny removed as an action modifier or unconfiguring the egress ACL itself causes all traffic ingressing a port to be dropped PD4 307360639 An abstract warning message is printed on a port being added as a tagged port in a learning domain when it is untagged in a different vMAN and vice versa
200. r EEPROM memory test failed PD3 203116541 MSM A and MSM B May Display EEPROM Checksum Failed Error Following EEPROM checksum failed error messages may be seen in the syslog MSM B card eeprom checksum failed Oxb8a 0xb89 MSM A card eeprom checksum failed Oxb66 Oxb65 Backplane eeprom checksum failed Oxd71 Oxcd5 EAPS PD4 326832374 Streams Are Flooded in All Active Ports for the Temporary Flood Duration Streams are flooded in all active ports for the temporary flood duration after running the restart ports all command because a kill entry is not getting installed ExtremeXOS 12 1 4 Installation and Release Notes Table 32 Platform Specific and Feature PDs Continued PD Number PD4 314278544 PD3 104885349 Description Traffic Drop Occurs When Changing an EAPS State A traffic drop is seen when an EAPS state changes from link down to link up even with add link ports on Traffic Loss Occurs When a Shared Link Comes Up When traffic is running between shared links FDB entries are incorrectly learned on BlackDiamond 10808 and BlackDiamond 12804 switches Traffic loss occurs until the incorrectly learned FDB entries age out PD3 97153785 If Multiple Shared Links are Down a Loop is Created In a specific EAPS topology if multiple shared links are down a loop is created PD3 54870537 PD3 45729158 ESRP PD3 52741820 IP Routing Protoco PD3 132508261 IPv6 Unicast PD3 13971488
201. r extremeMemoryMonitorSystemTable on MSM B after an MSM failover the switch always returns the value set for MSM A PD4 572997662 The SNMP GetNext for the extremeClearflow MIB causes the ACL process to die with a signal 6 error Spanning Tree Protocol PD4 692156614 Part of an STP configuration is lost when auto bind and manual port mode are used PD4 490740265 PD4 479984841 The command output for the show configuration stp command does not show the configured Multiple Spanning Tree Protocol MSTP region PD4 397626801 STP edge safeguard and network login are supported on the same port PD4 451796699 Multiple Spanning Tree Protocol MSTP port status changes from internal to boundary after a switch is rebooted ExtremeXOS 12 1 4 Installation and Release Notes Resolved Issues in ExtremeXOS 12 1 2 17 patch1 17 The following issues were resolved in ExtremeXOS 12 1 2 17 patch1 17 The numbers shown in column one of the following table are for internal reference and can be ignored ExtremeXOS 12 1 includes all fixes up to and including ExtremeXOS 11 1 4 4 ExtremeXOS 11 2 3 3 ExtremeXOS 11 3 4 5 ExtremeXOS 11 4 4 7 ExtremeXOS 11 5 2 10 ExtremeXOS 11 6 4 11 through patch1 8 and ExtremeXOS 12 0 3 16 through patch1 13 For information on those fixes see the release notes for the specific release Table 50 Platform Specific and Feature PDs PD Number General PD4 620606253 PD4 576392401 De
202. ration in the upgraded image ExtremeXOS 12 1 4 Installation and Release Notes Upgrading ExtremeXOS on a Summit X450 Upgrade a Summit X450 to ExtremeXOS 12 1 4 as follows 1 Save your configuration to a backup configuration file using the save configuration command You must save your configuration to a backup configuration file in order to revert to your currently running image if the need arises 2 Download the latest image to the switch Download the image to the switch using the download image command Download ExtremeXOS 12 1 image summitX 12 1 4 xos 3 Determine your current active image partition by running the show switch command The Image Booted field shows the current active partition 4 Download the ExtremeXOS 12 1 4 image to the alternate partition using the following command download image lt ipaddress gt lt filename gt vr lt vrname gt lt image partition gt For example if your current image is running in the primary partition download the new image in the secondary partition download image 10 60 116 11 summitX 12 1 4 xos vr vr mgmt secondary 5 Reboot the switch Use the reboot command to reboot the switch Upgrading an MSM 5 and MSM 5R to ExtremeXOS 12 1 ona BlackDiamond 12802 Upgrade the MSM 5 or MSM 5R to ExtremeXOS 12 1 4 as follows 1 From the Extreme Networks eSupport website download the ExtremeXOS 12 1 4 FCS image to your TFIP server When powered up the BlackDiamond 12802 comes up as a
203. rding profile synchronize Synchronize entire primary MSM to backup MSM stacking Synchronize stacking configuration unconfigure Unconfigure system configuration stacking Settings for stacking vlan vlan_name router discovery IPv6 router discovery vlan vlan_name udp profile ExtremeXOS 12 1 4 Installation and Release Notes UDP forwarding profile Tested Third Party Products This section lists the third party products tested for ExtremeXOS 12 1 Tested RADIUS Servers The following RADIUS servers are fully tested Microsoft Internet Authentication Server Funk Software Steel Belted RADIUS Enterprise Edition 4 5 Meetinghouse FreeRADIUS Tested Third Party Clients The following third party clients are fully tested e Funk Odyssey 2 2 e MeetingHouse Data AEGIS 2 0 5 e Odyssey 3 03 0 1194 PoE Capable VoIP Phones The following PoE capable VoIP phones are fully tested Avaya 4620 Avaya 4620SW IP telephone Avaya 9620 Avaya 4602 Avaya 9630 Avaya 4621SW Avaya 4610 Avaya 1616 Avaya one X Cisco 7970 Cisco 7910 Cisco 7960 ShoreTel ShorePhone IP 212k ShoreTel ShorePhone IP 560 ShoreTel ShorePhone IP 560g ShoreTel ShorePhone IP 8000 ShoreTel ShorePhone IP BB 24 Siemens OptiPoint 410 standard 2 ExtremeXOS 12 1 4 Installation and Release Notes Siemens OpenStage 20 Siemens OpenStage 40 Siemens OpenStage 60 Siemens OpenStage 80 Extreme Switch Securi
204. re than 32 LAGs on a switch or stack that does not support larger configurations the system displays the following error message Error Slot lt slot_number gt can support a maximum of 32 trunks If you want to configure more than 32 LAGs on a BlackDiamond 8800 switch it is not necessary to remove the 10G4X module however you must both unconfigure the slot holding the 10G4X module and disable the slot holding that module or remove the 10G4X module Use the following commands to unconfigure the slot and disable that slot unconfigure slot and disable slot If you want to configure more than 32 LAGs on a SummitStack you must remove all original Summit X450 switches from the active topology If you attempt to insert a 10G4X module into a BlackDiamond 8800 chassis configured for more than 32 LAGs or if you attempt to add an original X450 module into a SummitStack with more than 32 LAGs the module fails the Init state with log error messages at the warning level similar to the following 04 07 1921 23 52 28 29 lt Warn DM Warning gt MSM A Slot 8 FAILED 1 Error Max Load Share Groups Exceeded 48 from HAL on CardExec INIT 5 for slot 04 07 1921 23 52 28 29 lt Warn DM Warning gt MSM A Error Max Load Share Groups Exceeded 48 from HAL on CardExec INIT 5 for slot 8 Once you configure more than 32 LAGs on a BlackDiamond 8800 chassis or SummitStack the 10G4X or original Summit X450 series module will not initialize even if you r
205. rectly installs default routes to each other Traffic is forwarded through a BVLAN even if the BVLAN is disabled VPLS goes into SGNL state after changing VPLS to take RSVP LSP from static LSP as a transport LSP Workaround Disable and enable MPLS to bring up VPLS PD3 202006051 Quickly executing the following pairs of configuration commands may cause errors On a single MSM the second command is rejected and an error is printed On a dual MSM the command may pass on the backup MSM and then fail on the primary MSM resulting in an out of sync condition disable igmp snooping vlan myvlan configure vpls myvpls add service vlan myvlan configure vpls myvpls delete service myvlan enable igmp snooping vlan myvlan Workaround Pause between issuing the commands If the problem occurs on a single MSM re enter the last command If the problem occurs on a dual MSM the last command will need to be undone for example configure vpls myvpls delete service myvlan or disable igmp snooping vlan myvlan and re entered PD3 116409584 When enabling the LDP loop detection feature the path vector TLVs LSR IDs are not updated To workaround this issue disable and enable MPLS PD3 116640291 Multicast PD4 325245190 LDP path vector loop detection may not perform as expected For example the LSR can advertise and propagate path vector TLVs but will not reject FECs whose path vector value exceeds the configured path vector limit
206. regation group when a stack master is power cycled ExtremeXOS 12 1 4 Installation and Release Notes Table 49 Platform Specific and Feature PDs Continued PD3 204965477 On a BlackDiamond 10808 switch or BlackDiamond 12800 series switches before loading an ASCII configuration on an unconfigured switch using the load script command delete the ports from the default VLAN using the configure default delete ports all command and delete the ports from the default virtual router using the configure vr vr default delete ports lt port_list gt command PD4 445637097 BlackDiamond 10 PD4 435982111 When configuring sampling rates lower than the 256 default value the show sflow configuration command automatically rounds up the configured sample rate to 256 800 Switch A BlackDiamond 10808 series switch may in some cases experience the wrong CLEAR Flow rule trigger and associated actions Summit Family Switches PD4 572997403 PD4 214435711 PD4 683849348 When connecting two Summit X450a 24x switches using a dual speed SFP GBIC after disconnecting the dual speed 1O00FX 1000LX SFP receive fiber from one of the switches the remote port remains active After disconnecting the dual speed 1OOFX 1000LX SFP transmit fiber from the other Summit X450a 24x switch the local port remains active See New FEFI CLI Command in the feature enhancements section in the Overview chapter of this release note On a Summ
207. ring a multi port ACL use the following guideline For any a series or e series blade in the system its total ACL count as calculated by ACL rules times ports applied to should not exceed 48 000 total ACL rules For example applying a 1 000 rule policy file to a 48 port multi port list on an a series module on slot 1 and an e series module in slot 2 is fine Neither module exceeds the 48 000 total ACL rules Excessive boot times and CPU resource starvation can be seen with larger total rule counts If your application requires additional capacity contact Extreme Networks PD3 28320363 BGP PD3 209442785 Invalid Encapsulate Value for IPv6 In IPv6 the encapsulate value is next header which is not currently a valid attribute Static Multicast Route Will Not be Exported Using MBGP Static multicast routes are not exported using MBGP However a static unicast route can be exported using MBGP ExtremeXOS 12 1 4 Installation and Release Notes Table 32 Platform Specific and Feature PDs Continued PD Number Description CLEAR Flow PD4 278443631 CLEAR Flow Commands Display on Platforms That Do Not Support This Capability CLEAR Flow commands display on platforms that do not support this capability including the Summit X150 X250 X350 and X450e series switches as well as BlackDiamond 8800 non c series switches CLI PD3 71725881 Timezone DST Name Truncates at Seven Characters When configuring an option
208. rm the new image downloaded to the primary image 4 Verify the following before rebooting the backup MSM e Primary ver is the image to be downloaded e Image Selected is set to primary MSM MSM A MSM B Current State MASTER BACKUP In Sync Image Selected primary primary Image Booted secondary secondary ExtremeXOS 12 1 4 Installation and Release Notes Primary ver 12 1 2 122 Secondary ver 11 4 1 4 11 4 1 4 5 Run the reboot command to reboot MSM B only reboot msm b 6 Run the show switch command to verify that e MSM B is In Sync mode e Image Selected and Image Booted are both set for primary on the backup MSM MSM MSM A MSM B Current State MASTER BACKUP In Sync Image Selected primary primary Image Booted secondary primary Primary ver 12 1 2 12 ed 2 Secondary ver 11 4 1 4 11 4 1 4 7 Execute the run msm failover command from the master MSM MSM A MSM B becomes the master MSM and MSM A will reboot Run the show switch command to e Verify that MSM B is the master MSM and MSM A is the backup MSM and displays In Sync e Verify that Image Selected and Image Booted are set for primary on both MSMs MSM MSM A MSM B Current State BACKUP In Sync MASTER Image Selected primary primary Image Booted primary primary 10 Run the run msm failover command again so that MSM A becomes the master MSM 11 Run the show switch command to confirm the master MSM is
209. rms 1 024 permanent multicast IP routes IP unicast static routes maximum number of All platforms 1 024 permanent IP unicast routes IP route sharing maximum gateways BlackDiamond 8800 series 2 4 or 8 configurable maximum number of configurable i gateways used by equal cost multipath OSPF Summit 0e 2o fh T OSPFv3 or static routes Summit X450 2 4 or 8 ExtremeXOS 12 1 4 Installation and Release Notes Metric Product Limit IP route sharing total destinations maximum BlackDiamond 8800 series number of unique destinations used by default maximum gateways of 4 511 multipath OSPF OSPFv3 or static routes if maximum gateways is 2 1 023 if maximum gateways is 8 255 BlackDiamond 8800 c series default maximum gateways of 4 511 if maximum gateways is 2 1 023 if maximum gateways is 8 255 BlackDiamond 8800 a series default maximum gateways of 4 511 if maximum gateways is 2 1 023 if maximum gateways is 8 255 BlackDiamond 8800 e series default maximum gateways of 4 31 if maximum gateways is 2 63 if maximum gateways is 8 15 BlackDiamond 10808 with up to 8 gateways per destination 7 136 BlackDiamond 12800 series with up to 8 gateways per destination 7 136 Summit X250e default maximum gateways of 4 31 if maximum gateways is 2 63 if maximum gateways is 8 15 Summit X450 default maximum gateways of 4 511 if maximum gateways is 2 1 023 if maximum gate
210. rn in the ping test to a local but non existing host BlackDiamond 8800 Switch PD4 805462597 A slot fails on a BlackDiamond 8800 series switch when enabling dotlp examination inner tag ports on more than 24 ports in a vMAN BlackDiamond 10808 Switch PD4 1108500108 In some cases CLEAR Flow delta rule triggers while not needed on backup MSM IP Routing Protocols PD4 1231117748 In RIP Output route policy is applied to Input route policy internally after changing and refreshing Output route policy file Resolved Issues in ExtremeXOS 12 1 4 patch1 8 The following issues were resolved in ExtremeXOS 12 1 4 patch1 8 The numbers shown in column one of the following table are for internal reference and can be ignored ExtremeXOS 12 1 includes all fixes up to and including ExtremeXOS 11 1 4 4 ExtremeXOS 11 2 3 3 ExtremeXOS 11 3 4 5 ExtremeXOS 11 4 4 7 ExtremeXOS 11 5 2 10 ExtremeXOS 11 6 5 3 patch1 5 and ExtremeXOS 12 0 5 For information on those fixes see the release notes for the specific release Table 35 Platform Specific and Feature PDs PD Number Description BlackDiamond 10808 PD4 1372389633 With PIM snooping enabled on a pure L2 VLAN PIM snooping entries timeout without being refreshed even though PIM hello packets are received on the VLAN port This behaviour is only seen after a BlackDiamond 10808 switch fails over to MSM B and MSM A becomes the slave switch ExtremeXOS 12 1 4 Installation and Rel
211. ror messages at the warning level similar to the following 04 07 1921 23 52 28 29 lt Warn DM Warning gt MSM A Slot 8 FAILED 1 Error Max Load Share Groups Exceeded 48 from HAL on CardExec INIT 5 for slot 04 07 1921 23 52 28 29 lt Warn DM Warning gt MSM A Error Max Load Share Groups Exceeded 48 from HAL on CardExec INIT 5 for slot 8 Once you configure more than 32 LAGs the module will not initialize even if you reduce the number of LAGs to 32 you must reboot the system or SummitStack first The system logs an error message at the error level similar to the following when you must reduce the system even if you reduced the number of LAGs to 32 04 07 1921 23 52 28 29 lt Erro HAL Card Error gt MSM A Slot 8 is not supported when more than 32 load share groups have previously been configured A system reboot is required to clear this condition BlackDiamond 10808 switch BlackDiamond 12800 and 20808 series switches only The following guidelines apply to LAGs on the BlackDiamond 10808 12800 and 20808 series switches e A static LAG can include a maximum 16 ports e An LACP LAG can include a maximum of 32 ports out of these up to 16 can be selected links and the remaining 16 will be standby links e A Health Check LAG can include a maximum of 16 ports e The maximum number of LAGs is 128 e If you do not explicitly select an algorithm the port based scheme is used However the address base
212. round Do not configure the group address in the rp list with a non zero host portion PD3 200659931 Traffic May Take 210 Seconds to Recover After a Failover In a worst case scenario after a failover traffic may take 210 seconds to recover on a switch with a PIM DM configuration PD3 78144711 show ipstats Command Does Not Increment IGMPv3 Statistics The show ipstats command does not increment IGMPv3 statistics PD3 79383551 IGMPv3 Report Record Type 5 Message Does Not Work Correctly IGMPv3 Report Record type 5 does not work as expected when sent after a type 2 or a type 4 message PD3 2841008 Multicast Packets Getting Dropped when Sent at Line Rate With PIM when small sized multicast streams are ingressed at line rate there is an initial packet drop of 50 to 70 This is seen on BlackDiamond 8800 and Summit X450 switches PD3 139683642 PD3 16451411 Network Services PD3 166858162 show pim Command Only Counts Null Registers The output of the show pim command displays the cumulative counter for the PIM register in out and the register stop in out When the ExtremeXOS switch is a first hop router it sends out the real register first After a particular mroute has been established PIM then periodically sends the null register The Register out field does not count real registers it only counts null registers Second Combo Port Does Not Come After Reboot if First Combo Port i
213. rrrrrrrrrrrrrrrterrnt 103 Upgrading ExtremeXOS on a Summit X2506 se ssssssrssssrerssrsrrrrsrsrrrrsrsrrrrsrrnrrrnrrrrererrsreresre 104 Upgrading ExtremeXOS on a Summit X450 0 02 eee cee c cece eee eee eee e eee cesses sane aa eeea nese essa eeeee 105 Upgrading an MSM 5 and MSM 5R to ExtremeXOS 12 1 on a BlackDiamond 12802 105 ExtremeXOS 12 1 4 Installation and Release Notes Upgrading a BlackDiamond Series of Switches Using Hitless Upgrade cccccccceeeeeseeeeeeees 107 Upgrading the Alternate Partition Using Hitless Upgrade cccecseccsecceceeeeeeeeeeeeeseeeeeeeees 107 Dual MSM Systems with Different Images PresSent cccccccseceeeseeceeceeeeeeeeeeeeeseeeeeseeeeeeeeeees 108 Using a Rev 10 or later BlackDiamond 10808 MSM 1 or IMI SIME eean TAEA EAT AEE 109 Installing an ExtremeXOS MOdule cccccccseccecceeceeceeeseeseeceesseeeeeseeeeeseeeeeeeeeseeseeeeeeeeaeeseeeeeseeeas 110 Uninstalling an SSH Module ccccccccecccsceeeeeeeeeeeeeee eee eeseeeee esse eeeeeeeeeeseeeeseesseeeseeeseeeaeeeeaeeennes 111 Downgrading SWIKCHES ves danced sesks ceases caddies eee R eae eLa AEAEE aca dedavess AEPA E aaa EELEE SEENE REEERE NEA 111 Chapter 3 PAIS csias ee E a 113 Supported LIMITS erraina n aeaa a E EE A E EEEE EE Ea E A EEEE EAE EEE 113 Chapter 4 Open Issues Known Behaviors and Resolved Issues 0cccccesssseeeeeeeeeeeseeeeeeeneeeees 133 Open SSU Sicre ai Ee AIEE E FEO E ETA RE EE
214. rted for the next maximum hold time PD4 443515354 PD4 438482695 Protocol Independent Multicast PIM cache timeout should not be determined by the configured join prune interval on a VLAN PD4 402030777 Issuing the show log match command causes the emsServer process to crash with a signal 6 error PD4 446885541 On rare occasions the authentication authorization and accounting AAA process dies with signal 6 due to an assertion failure while authenticating an SSH user using TACACS PD4 376341922 Making web based calls using HTTP on an ExtremeXOS switch causes the switch to increase AAA memory utilization PD4 522345204 PD4 328163465 CPU utilization increases up to 99 9 when SNMP polls the extremeFdb MIB and generates the following error message 08 08 2008 18 27 36 45 MSM A CPU utilization monitor consumes 99 CPU process fdb PD4 443927611 BlackDiamond 10 PD4 449877739 PD4 411932475 ARP PD4 412404954 Multicast PD4 468874495 PD4 461246875 Traffic does not egress a 10G4Xc or 10G8Xc module with load sharing enabled 808 Switch A BlackDiamond 10808 switch with an I O module goes into a failed state and displays the following error in the system log MSM A Slot 6 FAILED 1 L2 ping thru MSM A timeout MSM A Slot 2 FAILED 1 L2 ping thru MSM A timeout MSM A Slot 2 FAILED 1 Control link ping timeout After an MSM failover a BlackDiamond 8800 switch w
215. rted on combo ports XENPAK Module Support XENPAK modules supported on the BlackDiamond 8800 series of switches with ExtremeXOS 12 1 and the minimum ExtremeXOS version required include Table 18 BlackDiamond 8800 Series of Switches XENPAK Support XENPAK Module ExtremeXOS Required LR TERIER ER aL ald SR iid ILS LX4 MESHES ZR IES AIRS CX4 12 0 1 11 XENPAK modules supported on the BlackDiamond 10808 switch with ExtremeXOS 12 1 and the minimum ExtremeXOS version required include Table 19 BlackDiamond 10808 Switch XENPAK Support XENPAK Module ExtremeXOS Required LR LLY ER 11 1 1 9 ExtremeXOS 12 1 4 Installation and Release Notes 7 Table 19 BlackDiamond 10808 Switch XENPAK Support XENPAK Module ExtremeXOS Required SR Wild tS LX4 WESI ZR 11 3 1 3 LW 11 4 1 4 XENPAK modules supported on the BlackDiamond 12804 switch with ExtremeXOS 12 1 and the minimum ExtremeXOS version required include Table 20 BlackDiamond 12804 Switch XENPAK Support XENPAK Module ExtremeXOS Required LR 11 4 1 4 ER 11 4 1 4 SR 11 4 1 4 LX4 11 4 1 4 ZR 11 4 1 4 LW 11 4 1 4 XENPAK modules supported on the BlackDiamond 12802 switch with ExtremeXOS 12 1 and the minimum ExtremeXOS version required include Table 21 BlackDiamond 12802 Switch XENPAK Support XENPAK Module ExtremeXOS Required LR 12 0 1 11 ER
216. rted on the Summit X150 series switches with ExtremeXOS 12 1 and the minimum ExtremeXOS version required include Table 12 Summit X150 Series Switches SFP Support SFP ExtremeXOS Required 1O0BASE FX 12 0 2 25 1OOBASE BX SFP 12 0 2 25 1OOBASE LX10 SFP 12 0 2 25 SX SFP 12 0 2 25 LX SFP 12 0 2 25 ZX SFP 1210 2125 LX100 SFP 12 0 2 25 1000BX SFP 12 0 2 25 SFPs supported on the Summit X350 series switches with ExtremeXOS 12 1 and the minimum ExtremeXOS version required include Table 13 Summit X350 Series Switches SFP Support SFP ExtremeXOS Required SX SFP 12 0 3 16 LX SFP 12 0 3 16 ZX SFP 12 0 3 16 LX100 SFP 12 0 3 16 1000BX SFP 12 0 3 16 ExtremeXOS 12 1 4 Installation and Release Notes SFPs supported on the Summit X450 switch with ExtremeXOS 12 1 and the minimum ExtremeXOS version required include Table 14 Summit X450 Switch SFP Support SFP ExtremeXOS Required 10 100 1000BASE T Copper SFP 12 0 2 25 Note Not supported on combo ports SX SFP 11 2 2 4 LX SFP 11 2 2 4 ZX SFP INA 1000BASE T SFP 11 2 2 4 100FX SFP 11 4 3 4 or 11 5 2 10 not supported in 11 5 1 4 Note Not supported on combo ports 1O0FX 1000LX SFP Note Not supported on combo ports TESIS LX100 SFP IZO 1000BX SFP 11 6 1 9 SFPs supported on the Summit X450a switch with ExtremeXOS 12 1 and the minimum ExtremeXOS version required include Tabl
217. rtise a default route to a BGP neighbor or to all neighbors in a peer group even though no default route exists in the local IP routing table It also allows you to associate policy rules to conditionally advertise a default route to BGP neighbors When default route origination becomes active the default route is advertised to the specified BGP neighbors overriding any previously sent default route If a default route is added to the local IP routing table while default route origination is active the default route defined by this feature takes precedence over the new regular default route If default route origination becomes inactive and a regular default route exists the regular default route is advertised to BGP neighbors The following sections provide additional information on this feature e Managing Policies for Default Route Origination on page 11 e Enabling and Disabling Route Origination on page 11 e Example Default Route Origination on page 11 ExtremeXOS 12 1 4 Installation and Release Notes Managing Policies for Default Route Origination When you use a policy with default route origination the default route is originated only if the local BGP RIB contains a route that matches the policy match conditions You can use the following match conditions e NIRI e AS path e Community Origin You can also use the following policy actions in the policy to set the route attributes e AS path e Community e Or
218. s A condition exists with some Mitel IP phones that are attached to an ExtremeXOS PoE enabled platform that requires that you disable and enable inline power in order for the phone to become active PD3 131375426 Autopolarity Does Not Work on Combo Ports Configuring autopolarity does not work on the combo ports on the Summit family of switches PD3 77711011 Slot Should Not be Included in show inline power stats Command Output The word slot should not be included in the output of the show inline power stats command ExtremeXOS 12 1 4 Installation and Release Notes Table 32 Platform Specific and Feature PDs Continued PD Number PD3 77711042 Description Priority Column Should Not be Included in show inline power configuration Command Output The Priority column should not display in the output of the show inline power configuration CLI command when running the command on a Summit X450 24p PoE switch PD3 43606168 PD3 40266236 PD3 40233121 SummitStack PD3 209191744 show log Command Output Filled with sFlow Receiver Missing Message If sFlow does not have a collector configured using the configure sflow collector command the show log command generates the following messages 08 23 2005 12 28 09 55 lt Noti sflow debug AddCntSmp1Fail gt Could not add the counter sample for port 0 1020 as receiver is not configured 08 23 2005 12 07 49 55 lt Noti sflow debug Add
219. s Redundant to Another Port On a Summit X250e 24x switch if one of the combo ports is redundant to a front panel port after rebooting the second combo port does not come up if the primary port for the SRP is active PD3 93829391 Configurations Using VR Mgmt Interface as RADIUS Client IP Do Not Load Configurations using a VR Mgmt interface as a RADIUS client IP may not load at boot up However using an interface in VR Default will load correctly PD3 67431351 Ingress Rate Limiting and Egress Rate Limiting are Mapping to Multiple Ports Configuring an ingress traffic queue and an egress traffic queue association to multiple ports in sequential order generates the following error Egress queue already associated to this ingress queue Configuration failed on backup MSM command execution aborted ExtremeXOS 12 1 4 Installation and Release Notes Table 32 Platform Specific and Feature PDs Continued PD Number PD3 67727590 Description vMAN ID ACL Translations May Fail with Transmit Errors Creating two sets of VMAN ACLs with 4 000 entries each and performing a vMAN ID translation on each ACL may generate the following error eee 03 15 2006 17 57 28 84 lt Info pm config openingFile gt MSM B Loading policy RLL20k from file config RLL20k pol 03 15 2006 17 57 32 46 lt Info pm config loaded gt MSM B Loaded Policy RLL20k number of entries 4002 a eee Error in alloc txmi txmi 0x9f2 txmdi Oxffffffff
220. s 3 0004 of IPv6 neighbor entries in hardware Black Diamond e0 esis 1 0009 BlackDiamond 8800 e series 2509 BlackDiamond 10808 112 000 BlackDiamond 12800 series 24 500 BlackDiamond 12800 R series 112 000 Summit X250e 2509 Summit X450a 1 0009 Summit X450e 2509 IPv4 routes maximum number of IPv4 routes BlackDiamond 8800 series 25 000 sett coat bas oT unease BlackDiamond 10808 1 000 000 BlackDiamond 12800 series 1 000 000 Summit series 25 000 IPv4 routes LPM entries in hardware number BlackDiamond 8800 c series 12 000 of IPv4 routes in hardware BlackDiamond 8800 a series 12 000 BlackDiamond 8800 e series 480 BlackDiamond 8800 series 8 000 BlackDiamond 10808 256 000 MSM 1 98 000 MSM 1XL 229 000 BlackDiamond 12800 series MSM 5 49 000 MSM 5R 229 000 MSM 6R 229 000 Summit X250e 480 Summit X450 8 000 Summit X450a 12 000 Summit X450e 480 ExtremeXOS 12 1 4 Installation and Release Notes Metric Product Limit IPv6 routes LPM entries in hardware number BlackDiamond 8800 c series 6 000 oi IPS routes in herenera BlackDiamond 8800 a series 6 000 BlackDiamond 8800 e series 240 BlackDiamond 10808 114 500 BlackDiamond 12800 series 114 500 Summit X250e 240 Summit X450a 6 000 Summit X450e 240 IP router interfaces maximum number of All platforms with Edge license or above 512 VLANs performing IP routing excludes sub VLANs IPv4 and IPv6 interfaces IP multicast static routes maximum number of All platfo
221. s configured to do so as described below IEEE 802 3x flow control provides the ability to configure different modes in the default behaviors Ports can be configured to transmit pause frames when congestion is detected and the behavior of reacting to received pause frames can be disabled TX You can configure ports to transmit link layer pause frames upon detecting congestion The goal of IEEE 802 3x is to backpressure the ultimate traffic source to eliminate or significantly reduce the amount of traffic loss through the network This is also called lossless switching mode The following limitations apply to the TX flow control feature e Flow control is applied on an ingress port basis which means that a single stream ingressing a port and destined to a congested port can stop the transmission of other data streams ingressing the same port which are destined to other ports e High volume packets destined to the CPU can cause flow control to trigger This includes protocol packets such as EDP EAPS VRRP and OSPF e When flow control is applied to the fabric ports there can be a performance limitation For example a single 1G port being congested could backpressure a high speed fabric port and reduce its effective throughput significantly To configure a port to allow the transmission of IEEE 802 3x pause frames use the following command enable flow control tx pause ports oO dd note To enable TX flow control RX flow control m
222. s supported on the current VR Syntax Description max paths Specifies the maximum number of paths The range is 1 to 8 The value 1 disables BGP ECMP A value greater than 1 enables BGP ECMP and specifies the maximum number of paths Default One BGP ECMP is disabled Usage Guidelines This command triggers the BGP decision process causing BGP to re install the entire BGP routing table into the IP forwarding table This activity requires a significant amount of switch processor resources so we recommend that you enable or disable the BGP ECMP feature before enabling the BGP protocol globally on a VR Run the enable iproute sharing command to ensure that BGP ECMP routes are programmed in the hardware Example The following command enables BGP ECMP and sets the maximum number of paths to 4 configure bgp maximum paths 4 History This command was first available in ExtremeXOS 12 1 3 Platform Availability This command is available on platforms with the appropriate license For complete information about software licensing including how to obtain and upgrade your license and what licenses are appropriate for this feature see the ExtremeXOS Concepts Guide Appendix A ExtremeXOS Software Licenses ExtremeXOS 12 1 4 Installation and Release Notes show bgp show bgp Description Displays BGP configuration information Syntax Description This command has no arguments or variables Default N A Usage Guide
223. scription The upload debug command returns the error Error tftp The Unknown host and the upload fails if the SNMP sysname contains spaces PD4 591177208 After executing the CLI command upload debug the EPM process crashes with signal 11 if the SNMP sysname is longer than 15 characters PD4 623659052 The extremeFdb MIB entry last updated field is not updated after adding extremeFdbMacExosFdbTable to the extremeFdb MIB PD4 510007350 Multicast PD4 564523051 All traffic ingressing ports on a XM 2HR module that goes to an egress rate limiting queue are being dropped Multicast traffic shows the incorrect dotlp replacement for CPU slowpath forwarded packets Spanning Tree Protocol PD4 539845558 PD4 558775541 Rapid Spanning Tree Protocol RSTP takes more than 4 seconds to forward unicast traffic after performing a topology change ExtremeXOS 12 1 4 Installation and Release Notes Resolved Issues in ExtremeXOS 12 1 2 17 patch1 15 The following issues were resolved in ExtremeXOS 12 1 2 17 patch1 15 The numbers shown in column one of the following table are for internal reference and can be ignored ExtremeXOS 12 1 includes all fixes up to and including ExtremeXOS 11 1 4 4 ExtremeXOS 11 2 3 3 ExtremeXOS 11 3 4 5 ExtremeXOS 11 4 4 7 ExtremeXOS 11 5 2 10 ExtremeXOS 11 6 4 11 through patch1 8 and ExtremeXOS 12 0 3 16 through patch1 13 For information on those fixes see the release notes for the
224. specified peer group Syntax Description peer group lt peer group name gt Specifies the BGP peer group for which the default routes are originated and advertised ipv4 unicast Specifies that the default routes apply to IPv4 unicast routes If you do not specify an address family the command applies to IPv4 unicast routes ipv4 multicast Specifies that the default routes apply to IPv4 multicast routes lt policy name gt Specifies a policy to be applied to the default routes during origination Default Disabled BGP does not automatically originate and advertise default routes to BGP neighbors Usage Guidelines This command can be successfully executed at any time irrespective of whether local BGP or the remote BGP peers are enabled or disabled The default routes are created regardless of whether or not there are matching entries in the IGP route table When a BGP neighbor is added to a peer group it does not inherit the default route origination configuration from the peer group Also default route origination for a neighbor and the associated peer group can be different If a policy is configured and specified in the command a default route can be originated only if there is a route in the local BGP RIB that matches the policy s match rules The default route s attribute can be modified using the same policy file by including statements in the set block of the policy Example The following command enables the origination a
225. st gt all Description Enables the switch to transmit pause frames Syntax Description port_list Specifies one or more ports or slots and ports Default Disabled Usage Guidelines With autonegotiation enabled the Summit family of switches and the BlackDiamond 8800 series switches advertise the ability to support pause frames This includes receiving reacting to stopping transmission and transmitting pause frames However the switch does not actually transmit pause frames unless it is configured to do so IEEE 802 3x flow control provides the ability to configure different modes in the default behaviors Use this command to configure the switch to transmit link layer pause frames when congestion is detected To enable TX flow control RX flow control must first be enabled Refer to the enable flow control rx pause ports command If you attempt to enable TX flow control with RX flow control disabled an error message is displayed Example The following command enables the tx flow control feature on ports 5 through 7 on a Summit switch enable flow control tx pause ports 5 7 History This command was first available in ExtremeXOS 12 1 2 patch 4 Platform Availability This command is available on the BlackDiamond 8800 series modules and the Summit family of switches ExtremeXOS 12 1 4 Installation and Release Notes show ports information show ports mgmt lt port_list gt information detail Descriptio
226. t X450 switch only supports 511 LPM routes The configure inline power budget command is not supported on Summit family and SummitStack switches PD4 822468393 PD4 803423872 An overheated SummitStack fails but the ports remain active and traffic continues to be forwarded PD4 788067297 ACL PD4 369088279 Multicast PD4 803604959 PD4 602286396 OSPF PD4 759590041 Multicast traffic is not forwarded after rebooting a standby switch in a stack If a dynamic ACL is applied to ingress and egress to two or more interfaces port or VLAN the configure access list delete all command does not delete the dynamic ACL from all interfaces Workaround Manually delete the dynamic ACL from each port or VLAN using one of the following commands configure access list delete ping port lt port list gt configure access list delete ping vlan lt vlan name gt When PIM hello packets are received ports are not detected as router ports The router port is detected based on the IGMP report received from an IP address but not on the actual PIM packet After a port in a VLAN is added to an OSPF area it takes about four seconds to update a neighboring switch PD4 767590126 In a jumbo frame environment an OSPFv3 neighbor gets stuck at EX_START PD4 241726909 If two routers both reachable from one another originate functionally equivalent AS external LSAs same destination cost and non zero forwarding address the L
227. tROM after downloading Answer yes or use the install bootrom command to install later Once the BootROM is downloaded and installed it replaces the previous image stored in the onboard FLASH memory and will be used at the next reboot 10 Upgrade the BootROM and PSU controller firmware BlackDiamond 8800 family of switches only ExtremeXOS 12 1 4 Installation and Release Notes dd note BootROMs installed by Manufacturing should never be forced to an earlier BootROM version unless explicitly instructed by Extreme Networks support Extreme Networks requires that you upgrade the MSMs I O modules and PSU controllers in the BlackDiamond 8800 series of switches with the BootROM and firmware images included in this release of ExtremeXOS This release of ExtremeXOS contains the following versions of the BootROM and firmware MSM BootROM 1 0 3 7 First available in ExtremeXOS 12 1 1 4 I O module BootROM 1 0 3 7 First available in ExtremeXOS 12 1 1 4 PSU controller firmware 2 13 First available in ExtremeXOS 11 4 1 4 Use the show version command to display the versions of the BootROM and firmware currently installed To install the new BootROM and firmware wait until the show slot command indicates the MSMs and I O modules are operational Then use the install firmware command This command will install the new BootROMs or firmware only on modules that have older BootROMs or firmware installed You will be asked if you want to instal
228. tch1 8 ccccccccccc ccc eeceeceeee eee eeseseeeeeeeeeeeeeeeeeeeaeeaeeeaes 160 Resolved Issues in ExtremeXOS 12 1 3 patch1 6 cece ccccceccee cece eeee eee eeeeeseeeseeeseeesaeeseeeenaes 161 Resolved Issues in ExtremeXOS 12 1 3 patch 1 40 cc cccccccc ccc ceceeceeeeeeeeeseseeeeeeeeeeeeeseeeeeaeeaeeeaes 163 Resolved Issues in ExtremeXOS 12 1 3 patch 1 2 ecccecccccccsceeeeeeeeeeeeesee eee eeseeeseeeseeeeeeeseeeenaes 165 Resolved Issues in ExtremeXOS 12 1 3 cccec eee cee eeceeecae eee eeeaeeeaeesaa essa essa eesaaesaeesaeesaeesaeesaaes 167 Resolved Issues in ExtremeXOS 12 1 2 17 patch1 17 00 0 cccccccceccseccce cece eeceeeeeeceeeeaeeeaeeeeaeeeaes 170 Resolved Issues in ExtremeXOS 12 1 2 17 patch 1 1 ccccceccsecceeeeeeeeseeeeeeceeeeaeeeaeeeeaeeeaes 171 Resolved Issues in ExtremeXOS 12 1 2 17 patch1 12 cc cccccccccecceccee cece eeseeeseeeceeeeaeeeaeeeeaeeeaes 172 Resolved Issues in ExtremeXOS 12 1 2 17 patch 1 10 cecccecceccee cece ceeeeeceeeceeeeeeeeaeeesaeeeaes 173 Resolved Issues in ExtremeXOS 12 1 2 17 patch 1 7 ccecccecccccccececeeeeeceeeeeeeeseeeseeeseeeeeeeeeeeeeaes 174 Resolved Issues in ExtremeXOS 12 1 2 17 patch 1 400 cccccccccceccceeecsecse eee eeseeeseeeseeeeeeeeeeeenaes 174 Resolved Issues in ExtremeXOS 12 1 2 17 patch1 3 cece cccc cece eecsseceeeceeeeseeeseeeseeeeeeeeeeeenaes 176 Resolved Issues in ExtremeXOS 12 1 2 17 oo ccecccc cece cece eee ee eee eee e eee eee ee see saeeaaeeea nese eeeeeeaaes
229. ting in EAPS When ping tracking is enabled for VRRP VRRP performs the failover based on a cumulative ping track failure instead of consecutive ping track failures Resolved Issues in ExtremeXOS 12 1 3 patch1 4 The following issues were resolved in ExtremeXOS 12 1 3 patch1 4 The numbers shown in column one of the following table are for internal reference and can be ignored ExtremeXOS 12 1 includes all fixes up to and including ExtremeXOS 11 1 4 4 ExtremeXOS 11 2 3 3 ExtremeXOS 11 3 4 5 ExtremeXOS 11 4 4 7 ExtremeXOS 11 5 2 10 ExtremeXOS 11 6 5 3 and ExtremeXOS 12 0 5 For information on those fixes see the release notes for the specific release Table 47 Platform Specific and Feature PDs PD Number General PD4 795451285 Description After disabling flooding for broadcast traffic the broadcast traffic originated from the switch is not flooded out PD4 701906049 The configured value of the sys recovery level resets to the factory default after disabling and enabling an I O module G48Xa PD4 581257425 An error occurs when loading an ExtremeXOS 12 1 or earlier software configuration file if the banner configuration contains a new line character PD4 504813986 In a DNS server if the RADIUS server IP address is specified as CNAME that is Alias a switch is not able to resolve the IP address correctly PD4 684400473 A switch does not generate high CPU utilization log messages after executing
230. tion Image Selected secondary Image Booted secondary Primary ver 11 4 1 4 Secondary ver 12 1 2 Config Selected primary cfg Config Booted primary cfg ExtremeXOS 12 1 4 Installation and Release Notes 2 Select the reboot partition Assuming that the 11 4 1 image is on the non booted partition if you are currently running the image booted from the primary partition run this command use image secondary If you are currently running the image booted from the secondary partition run this command use image primary 3 Select the reboot configuration Select the configuration to be used after reboot with the use configuration command Assuming you saved the 11 4 1 configuration as bdversion11_4_1_4 cfg use the following command use configuration bdversion1l1_ 4 1 4 4 Verify the image and configuration selection Again run the show switch command The output should show that the selected image is the 11 4 1 image that you are downgrading to and the selected configuration is the one you saved before you installed the 12 1 4 image Image Selected primary Image Booted secondary Primary ver 11 4 1 4 Secondary ver 12 1 3 14 Config Selected bdversion11_4 1 4 cfg Config Booted primary cfg 5 Reboot the switch Use the command reboot to reboot the switch ExtremeXOS 12 1 4 Installation and Release Notes EP Limits This chapter summarizes the supported limits in ExtremeXOS 12 1 4 Supported Limits Table
231. tion command e User configured VRs from default configurations can be copied and pasted to other switches with any errors Multicast manager crashes with signal 11 on hitless upgrade when upgrading from ExtremeXOS 11 6 or 12 0 to ExtremeXOS 12 1 2 or later PD4 654813987 When running ExtremeXOS 12 1 or later on a BlackDiamond 8800 a series c series or e series switch or the Summit family switches you cannot add IP multicast entries The following error message is displayed when trying to add entries Unable to Add IPmc sender entry Unable to Delete IPmc sender entry PD4 308157118 Screenplay PD4 626440761 PD4 597319891 sFlow PD4 446885634 When IGMP snooping is disabled ingress multicast data packets are not forwarded when vMAN Ethertype is 0x8100 Workaround Set the vMAN Ethertype to default Ox88a8 A memory leak occurs in process xmld after a user logs in and logs out of a switch using ScreenPlay sFlow samples every unicast and multicast packet received on sFlow enabled ports after CPU throttling sets the sampling rate to a maximum of 536870912 PD4 486083706 SNMP PD4 453123705 When sFlow is enabled on a port the incoming Virtual Router Redundancy Protocol VRRP announcements on that port are dropped causing dual VRRP masters on the attached switches The sFlow counters increase when enabled but the VRRP advertisements do not arrive at the other end When performing an SNMPwalk fo
232. to which Health Check LAG ports are to be added must be configured in loopback mode This is to prevent the vlan interface from going down if all ports are removed from the Health Check LAG In a normal LAG when all ports are removed from the aggregator the trunk is considered DOWN As a consequence if this were the only port in the VLAN the VLAN interface would be brought DOWN as well In the Health Check LAG situation this would cause the TCP monitoring to fail because the L3 vlan interface used by TCP monitoring would no longer send or receive TCP data The following commands are used to modify the configured Health Check LAG 1 Delete the monitoring configuration for a member port using the following command configure sharing health check member port lt port gt delete tcp tracking lt IP Address gt tcp port lt TCP Port gt Enable or disable monitoring for a member port in the Health Check LAG using the following command configure sharing health check member port lt port gt disable enable tcp tracking Health Check LAG Example The following example creates a Health Check LAG of 4 ports create vlan v1 configure vl ip 192 168 1 1 24 enable sharing 5 grouping 5 8 health check enable loopback mode v1 configure vl add port 5 configure sharing health check member port configure sharing health check member port configure sharing health check member port configure sharing health check member port add track tcp 192 1
233. treams IGMPv1 v2 SSM mapping for PIM SSM RSTP MSTP m Performance improvement m Cisco interoperability DHCP Option 82 at Layer 2 Network login enhancements m Configurable netlogin dotlx client reauthentication m Authentication failure VLAN m Authentication server unavailable VLAN Web based network login enhancements m Logout fault tolerance in case of lost keep alive packets in the presence of a logout pop up window User configurable content refresh keep alive timer value Proxy port support m URL redirection support for adding user configurable TCP port numbers such as 8080 m Configurable TCP port for redirect page after a successful login Network login redirect page disabled Custom image in logout popup window Reauthentication on refresh that is credentials are reverified after a session refresh Support for authentication failure VLAN and service unavailable VLAN CLI to blackhole FDB m Unicast m Multicast Static unicast FDB with multiple ports using ACL and combining MAC entries when possible Unicast Reverse Path Forwarding for BlackDiamond 10808 and BlackDiamond 12800 series switches Mirroring enhancements m Remote mirroring BGP m Route refresh m Cease subcodes m Allow looped BGP AS Path m Extended community Disable learning option for flooding instead of dropping Multicast MIBs RFC 2933 2934 Ping traceroute MIB ExtremeXOS 12 1 4 Installation and Release Notes CLI scripting Policy
234. ty Assessment DoS Attack Assessment Tools used to assess DoS attack vulnerability e Network Mapper NMAP ICMP Attack Assessment Tools used to assess ICMP attack vulnerability e SSPing e Twinge e Nuke e WinFreeze Port Scan Assessment Tools used to assess port scan assessment e Nessus ExtremeXOS 12 1 4 Installation and Release Notes Upgrading to ExtremeXOS 12 1 This chapter contains the following sections Staying Current on page 97 Upgrading ExtremeXOS on page 97 Installing an ExtremeXOS Module on page 110 Uninstalling an SSH Module on page 111 Downgrading Switches on page 111 Staying Current If you are an Extreme Assist customer the latest release and release notes are available after logging in to the Tech Support web site at http Awww extremenetworks com go esupport htm For more information about ExtremeXOS see the ExtremeXOS Concepts Guide and the ExtremeXOS Command Reference Guide Upgrading ExtremeX0S Upgrading your current ExtremeXOS installation to ExtremeXOS version 12 1 is a multistep process In this section is a quick summary of the necessary steps followed by detailed instructions Oo dd note Hitless upgrade from ExtremeXOS 12 0 and earlier to ExtremeXOS 12 1 and later is not supported on the BlackDiamond 12800 switch oO dd NOTE Hitless upgrade for network login is not supported when upgrading from an earlier version of ExtremeXOS software to ExtremeXOS 12 1
235. ubconfed community attribute Specifies a community number Specifies an autonomous system ID 0 65535 Specifies the BGP community number Specifies all routes with a given or larger mask length Specifies a subnet mask length number of bits Specifies an IP address and netmask Specifies an exact match with the IP address and subnet mask If no address family is specified IPv4 unicast is the default Usage Guidelines The option network any lt netMaskLen gt displays all BGP routes whose mask length is equal to or greater than lt maskLength gt irrespective of their network address The option network any lt netMaskLen gt exact displays all BGP routes whose mask length is exactly equal to lt maskLength gt irrespective of their network address ExtremeXOS 12 1 4 Installation and Release Notes Example The following command displays detailed information about all BGP routes show bgp Feasible Routes routes all Destination gt 13 0 0 0 8 10911 1239 m gt i3 0 0 0 8 10911 1239 m gt i3 0 0 0 8 10911 1239 gt 14 17 226 0 24 10911 3561 m gt 14 17 226 0 24 10911 3561 Peer Next Hop 80 0 0 69 80 0 0 1 90 0 0 69 90 0s 01 60 0 0 69 60 0 0 1 80 0 0 69 80 0 0 1 90 0 0 69 900 01 LPref Weight MED 100 1 100 I 100 I 100 1 100 1 The following command displays detailed information about all BGP routes show bgp routes detail all Feasible Routes Route 3 0 0 0 8
236. uld Not be Allowed in Load Sharing in SummitStack Switches If you create a load sharing group trunk then enable mirroring to a port the software allows you to add the mirroring port to the load sharing group Enabling Load Sharing on a Mirrored Port Enabling load sharing on a port that is being mirrored causes the mirroring to stop Adding a Static Route With MPLS LSP Adding a static route with an MPLS LSP may cause one of the following problems e If a static route is added with an MPLS LSP whose transport setting is IP traffic deny the route is displayed with an invalid nexthop in the show iproute mpls command output e When a static route is added with an MPLS LSP that is not present in show iproute mpls command output For example if there are 17 RSVP TE LSPs to the same destination only 16 LSPs are eligible for carrying traffic because of a maximum ECMP path limit of 16 Adding static routes with 17 LSPs results in the same observation PD3 157687121 Control Channel Type Router Alert Label Not Found in VCCV Packets ExtremeXOS software uses Control Channel Type 2 to indicate router alert label mode In MPLS Router Alert Label mode VCCV packets are encapsulated in a label stack However the existing VCCV packets are sent like a stack without any PW label PD3 184989177 Enabling LDP advertise static all Removes Ingress LSPs Using Static Routes When an LDP advertise static setting is set to all all static ro
237. um ping tracks maximum number All platforms with Advanced Edge license of ping tracks per VRRP Instance under 128 or above VRRP instances Hello interval 100 milliseconds 2 Frequency 3 seconds Miss 3 Hello interval 1 second Frequency 3 seconds Miss 3 VRRP maximum iproute tracks maximum All platforms with Advanced Edge license 8 number of iproute tracks per VLAN or above VRRP maximum number of VLAN tracks per All platforms with Advanced Edge license 8 VLAN or above XML requests maximum number of XML BlackDiamond 8800 c series with 100 requests per second DACLs Note Limits are dependent on load and type of with 100 DACLs 10 XML request These values are dynamic ACL with 500 DACLs 3 ceia requesie BlackDiamond 12800 series with MSM 6R with 100 DACLs 10 with 500 DACLs 3 Summit X450a with 100 DACLs 4 with 500 DACLs 1 a An ACL mask defines a unique match criteria and relative rule precedence Masks are automatically generated based on the contents of an access list policy Only adjacent rules within the policy that have identical match criteria will utilize the same ACL mask For this reason it is advantageous to list all rules with the same match criteria together unless a rel ative precedence with other policy rules is required Using VLAN based or wildcard ACLs requires the ACL masks to be allocated on every port in the system b The table shows the total available see the note included in PD3 77983510
238. unicast traffic enable bgp address family ipv4 unicast advertise inactive route History This command was first available in ExtremeXOS 12 1 3 Platform Availability This command is available on platforms with the appropriate license For complete information about software licensing including how to obtain and upgrade your license and what licenses are appropriate for this feature see the ExtremeXOS Concepts Guide Appendix A ExtremeXOS Software Licenses ExtremeXOS 12 1 4 Installation and Release Notes show bgp show bgp Description Displays BGP configuration information Syntax Description This command has no arguments or variables Default N A Usage Guidelines None Example The following command displays BGP configuration information show bgp Enabled RouterId LocalPref Always Compare MED Route Reflector IGP Synchronization Routes from EBGP Routes redistributed Fast Ext Fallover ConfedId Confed Peers Yes 10 203 134 73 100 Disabled No Disabled 2 0 Disabled 0 Operational Status Shut Prio OperStatus As MED Aggregation RR ClusterId Routes from IBGP Out Updates queued Maximum ECMP Paths down rity Policy Networks Aggregate Networks Redistribute ipv4 Admin unicast Status Direct Disabled Static Disabled RIP Disabled OSPFIntra Disabled OSPFInter Disabled OSPFExt1 Disabled OSPFExt2 Disabled ISISL1 Disabled Extr
239. ure see the ExtremeXOS Concepts Guide Appendix A ExtremeXOS Software Licenses ExtremeXOS 12 1 4 Installation and Release Notes enable bgp neighbor originate default enable bgp neighbor lt remoteaddr gt neighbor all faddress family ipv4 unicast ipv4 multicast originate default policy lt policy name gt Description Enables the origination and advertisement of a default route to a single BGP neighbor or to all BGP neighbors Syntax Description neighbor lt remoteaddr gt Specifies the IP address of a BGP neighbor for which the default route is originated and advertised neighbor all Specifies that default routes are to be originated and advertised for all BGP neighbors ipv4 unicast Specifies that the default routes apply to IPv4 unicast routes If you do not specify an address family the command applies to IPv4 unicast routes ipv4 multicast Specifies that the default routes apply to IPv4 multicast routes lt policy name gt Specifies a policy to be applied to the default route origination Default Disabled BGP does not automatically originate and advertise default routes to BGP neighbors Usage Guidelines This command can be successfully executed at any time irrespective of whether local BGP or the remote BGP peer is enabled or disabled The default route or routes are created regardless of whether or not there are matching entries in the IP route table When a BGP neighbor is added to a peer
240. ure sharing health check member port add tep tracking command ExtremeXOS 12 1 4 Installation and Release Notes History This command was first available in ExtremeXOS 10 1 The address based algorithm was added in ExtremeXOS 11 0 The L2 and L3 optional parameters were added in ExtremeXOS 11 1 IPv6 compatibility was added in ExtremeXO S 11 2 Dynamic link aggregation using LACP was added in ExtremeXO S 11 3 The L3_L4 optional parameter was added in ExtremeXOS 11 5 SummitStack functionality was added in ExtremeXOS 12 0 Health check link aggregation was added in ExtremeXOS 12 1 3 Platform Availability This command is available on all platforms ExtremeXOS 12 1 4 Installation and Release Notes show ports sharing show ports sharing Description Displays port load sharing groups or link aggregation groups LAGs Syntax Description This command has no arguments or variables Default N A Usage Guidelines Output from this command displays the following information Config Master The port that is configured as the master logical port of the link aggregation group LAG This number is also the LAG group ID Current Master In LACP this is the port that is currently the LAG group ID or master logical port for the LAG Agg Control This is the aggregation control for the specified LAG it can be either static LACP or health check In LACP it is the aggregation control for the specified LAG
241. uring a switch with HTTPS PD4 539277416 Failsafe account authentication fails when trying to access a switch using SSH by way of a management port PD4 772840867 An Extreme Networks switch ignores the string priv_Ivl in a TACACS authorization reply packet PD4 694359201 Process cliMaster dies with signal 6 in some cases PD4 507170653 Policy files containing 850 entries with flood groups causes an Extreme Process Manager BlackDiamond 88 PD4 841 184307 PD4 238870391 EPM watchdog reboot 00 Series Switch When STP notifies EAPS that it has flushed an FDB table EAPS no longer performs an additional FDB flush of the local switch The additional flush was not necessary and had a side effect of inadvertently unauthenticating netlogin clients on the local switch PD4 769156523 The message MSM A Error while saving psePort is displayed when a save command is executed after reconfiguring a slot as a G48te2 PoE to a G48te2 module PD4 767590011 A devmgr process crash may occur when the show version command is executed ExtremeXOS 12 1 4 Installation and Release Notes Table 46 Platform Specific and Feature PDs Continued BlackDiamond 12800 Series Switch PD4 698686480 Even after a vMAN ethertype is changed using the CLI packets are egressing out the service vMAN using an older vMAN ethertype Summit Family Switches PD4 805737496 SummitStack PD4 707855726 A Summi
242. ust first be enabled If you attempt to enable TX flow control with RX flow control disabled an error message is displayed To configure a port to return to the default behavior of not transmitting pause frames use the following command disable flow control tx pause ports RX You can configure the switch to disable the default behavior of responding to received pause frames Disabling rx pause processing avoids dropping packets in the switch and allows for better overall network performance in some scenarios where protocols such as TCP handle the retransmission of dropped packets by the remote partner To configure a port to disable the processing of IEEE 802 3x pause frames use the following command ExtremeXOS 12 1 4 Installation and Release Notes disable flow control rx pause ports a gt NOTE To disable RX flow control TX flow control must first be disabled If you attempt to disable RX flow contro with TX flow control enabled an error message is displayed To configure a port to return to the default behavior of enabling the processing of pause frames use the following command enable flow control rx pause ports ExtremeXOS 12 1 4 Installation and Release Notes disable flow control rx pause ports disable flow control rx pause ports lt port_list gt all Description Disables the processing of received pause flow control messages Syntax Description port_list Specifies one or more ports or slots
243. ute advertisement for IPv4 unicast traffic disable bgp address family ipv4 unicast advertise inactive route History This command was first available in ExtremeXOS 12 1 3 Platform Availability This command is available on platforms with the appropriate license For complete information about software licensing including how to obtain and upgrade your license and what licenses are appropriate for this feature see the ExtremeXOS Concepts Guide Appendix A ExtremeXOS Software Licenses ExtremeXOS 12 1 4 Installation and Release Notes enable bgp advertise inactive route enable bgp address family ipv4 unicast ipv4 multicast advertise inactive route Description Enables advertisement of BGP inactive routes which are defined as those routes that rated best by BGP and not best in the IP routing table Syntax Description ipv4 unicast Enables inactive route advertisement for IPv4 unicast routes If you do not specify an address family the command applies to IPv4 unicast routes ipv4 multicast Enables inactive route advertisement for IPv4 multicast routes Default Disabled Usage Guidelines This command can be successfully executed only when BGP is globally disabled It is best to enable this feature before you enable BGP enable bgp If BGP is enabled you must disable BGP disable bgp enable this feature and then enable BGP Example The following command enables inactive route advertisement for IPv4
244. utes are treated as egress routes and egress LSPs are created That is a label is generated and advertised for the static route If the router at the end of the static route advertises a label matching that static route the LSP that was previously an egress LSP becomes a transit LSP An ingress LSP should also be created whenever a label is received however the ingress LSP is never created Workaround Do not use the LDP advertise static all configuration in situations where an ingress LSP for a static route is required PD3 202184409 Adding Deleting a LAG Sharing Port Changes the VLAN Status Adding deleting a LAG sharing port changes the VLAN status which is causing an OSPF MPLS reconvergence ExtremeXOS 12 1 4 Installation and Release Notes Table 32 Platform Specific and Feature PDs Continued PD Number PD3 139423053 PD3 121985381 Description RSVP TE LSP Summary Statistics Take Excessive Time to Calculate Running the show mpls rsvp te lsp summary command on a system configured with 2 000 ingress LSPs takes an excessive amount of time to process Packets Larger than Configured Jumbo Frame Size are Forwarded You cannot configure an IP MTU that is greater than the configured jumbo frame size However when the jumbo frame size is configured using a smaller value than the IP MTU the configuration is accepted and the traffic is forwarded using the larger packet sizes PD3 118914021 Label Not Advertise
245. vertise vendor specific dot1 port protocol vlan id vlan lt vianname gt command PD4 901582203 The typographical error in the following error message has been corrected lt Warn AAA RADIUS serverSwitch gt MSM A Switch to server Summit Family Switches PD4 997419038 When dot1x and MAC based authentication are both enabled on a port and a user is first authenticated using MAC based authentication while dot1x authentication is also running the response from the RADIUS server is dropped PD4 986904840 Multicast PD4 1008069840 Network Login PD4 464577708 FDB entries are aging out even after receiving packets on the connected port Enabling IGMP snooping globally results in an error for remote mirroring VLANs A web based network login client cannot be authenticated using the URL http lt switch ip gt hello or http lt switch ip gt login ExtremeXOS 12 1 4 Installation and Release Notes Table 42 Platform Specific and Feature PDs Continued PD Number Description SNMP PD4 902287187 The EXTREME V2TRAP MIB definition misses the EapsRingPort at the IMPORTS section Because of this the Spectrum NMS fails to compile the ExtremeXOS 12 1 3 MIB file with an error against EapsRingPort Resolved Issues in ExtremeXOS 12 1 4 The following issues were resolved in ExtremeXOS 12 1 4 The numbers shown in column one of the following table are for internal reference and can be ignored Extrem
246. virtual port mirroring filters for each of the non master member ports PD3 203759919 When Disabling and Enabling MSDP the Peers Do Not Come up After disabling and enabling Multicast Source Discovery Protocol MSDP the peers do not come up Workaround Run the disable msdp command followed by the enable msdp command PD4 318846862 L3 Multicast Traffic in a VPLS vMAN is Forwarded Twice When the LSP is Changed L3 multicast traffic in a Virtual Private LAN Services VPLS vMAN is forwarded twice when the Label Switched Path LSP is changed to port sharing and is then changed back PD4 235071630 Direct Routes Are Not Stored in the Multicast Routing Table Direct routes are not stored in the multicast routing table which may cause problems processing anycast rendezvous points RPs PD3 128093864 PD3 188594038 MSDP SA Responses from non RPF Peers are Not Processed MSDP Source Active responses received from non RPF peers are not processed IP Traffic is Not Sent Across MPLS PHP Network IP traffic is not transmitted across an MPLS PHP enabled network ExtremeXOS 12 1 4 Installation and Release Notes Table 32 Platform Specific and Feature PDs Continued PD Number PD3 189399801 Description show pim rp set Command Does Not Always Show All Rendezvous Points The command output for the show pim rp set command does not always show all the Rendezvous Points for a multicast group Worka
247. ways is 8 255 Summit X450a default maximum gateways of 4 511 if maximum gateways is 2 1 023 if maximum gateways is 8 255 Summit X450e default maximum gateways of 4 31 if maximum gateways is 2 63 if maximum gateways is 8 15 IP multinetting secondary IP addresses All platforms 64 maximum number of secondary IP addresses per VLAN IS IS adjacencies maximum number of BlackDiamond 8800 series 128 supported IS IS adjacencies Black Diamond 10808 255 BlackDiamond 12800 series 255 Summit X450 and X450a 128 IS IS ECMP maximum number of equal cost BlackDiamond 8800 series configurable 2 4 or 8 mutigen for ISA BlackDiamond 10808 8 BlackDiamond 12800 series 8 Summit X450 and X450a configurable 2 4 or 8 ExtremeXOS 12 1 4 Installation and Release Notes Metric Product Limit IS IS interfaces maximum number of interfaces All platforms 255 that can support IS IS IS IS routers in an area recommended All platforms 256 maximum number of IS IS routers in an area IS IS route origination recommended maximum BlackDiamond 8800 series 20 000 eee that can be originated by an BlackDiamond 10808 30 000 BlackDiamond 12800 series 30 000 Summit X450 and X450a 5 000 IS IS IPv4 L1 routes in an L1 router BlackDiamond 8800 series 25 000 recommended maximum number of IS IS Level gt 1 routes in a Level 1 IS IS router BlackDiamond 10808 MSM 1 120 000 MSM 1XL 180 000 BlackDiamond 12800 series MSM 5 10
248. witch This example assumes that your TFTP server s IP address is 192 168 0 12 substitute your own address when you run the command ping vr vr mgmt 192 168 0 12 ping vr vr default 192 168 0 12 At least one of these commands must successfully reach your TFIP server for you to download the image When you download the image in step 6 specify the virtual router that allowed you to reach your TFIP server Save your configuration to a backup configuration file You must save your configuration to a backup configuration file or you will be unable to revert to your currently running image if the need arises In this example we use the software version number as part of the name Use the following command to save the configuration to the file version11_6_1_7 cf save configuration versionl1_6_1_7 As an optional extra precaution we suggest that you save this configuration to a TFIP server Use the tftp command to save your configuration In the following example the TFIP server s IP address is 192 168 0 12 the virtual router determined in step 2 is vr mgmt and the configuration file is version11_6_1_7 cfg tftp 192 168 0 12 v vr mgmt p 1l versionl1_6_1_7 cfg Determine your selected and booted image partitions Run the show switch command to determine your current selected and booted image partitions The selected image partition indicates which image will be used at the next reboot The booted image partition indicates which imag
249. witches L2 for Layer 2 and L3 for Layer 3 If the packet is not IP the switch applies the Layer 2 algorithm which is the default setting m Summit X150 X250e X350 X450a X450e and X650 series switches L2 for Layer 2 L3 for Layer 3 and L3_L4 for Layer 3 Layer 4 Oo dd note You cannot configure port based load sharing algorithm on the Summit family of switches you configure only address based load sharing algorithms BlackDiamond 8800 series switch and SummitStack only The following guidelines apply to link aggregation on the BlackDiamond 8800 series switch e A static LAG can include a maximum of 8 ports e An LACP LAG can include a maximum of 16 ports out of these up to 8 can be selected links and the remaining 8 will be standby links e A Health Check LAG can include a maximum of 8 ports e Any broadcast multicast or unknown unicast packet is transmitted on a single port in the LAG dd NOTE You cannot configure port based load sharing algorithm on the BlackDiamond 8800 series switch and the Summit family of switches you configure only address based load sharing algorithms e The available address based parameters on the BlackDiamond 8800 series switch are L2 for Layer 2 and L3 for Layer 3 If the packet is not IP the switch applies the Layer 2 algorithm which is the default setting e Beginning with ExtremeXOS version 11 5 for the BlackDiamond 8800 series switches and ExtremeXOS version 12 0 for Summ
250. wnload the image to your TFIP server Verify which virtual router connects to your TFTP server Save your configuration to a backup configuration file Determine your selected and booted image partitions Select the download partition and partition to use on reboot Download and install the image to the switch Reboot the switch Save the configuration for the new image Upgrade the BootROM BlackDiamond 10808 switch only 10 Upgrade the BootROM and PSU controller firmware BlackDiamond 8800 family of switches only 11 Upgrade the BootROM and PSU controller firmware BlackDiamond 12804 family of switches only oO dd Note If you have a dual MSM system and the software image is not the same on both MSMs see the section Dual MSM Systems with Different Images Present on page 108 O MON BD UV FF WO NY me ExtremeXOS 12 1 4 Installation and Release Notes Detailed Steps oO dd note Extreme Networks recommends using a TFTP server that supports blocksize negotiation per RFC 2348 Using this type of server enables the switch to download the images faster To upgrade to ExtremeXOS 12 1 on your system follow these steps 1 Download the image to your TFIP server Download the image you received from Extreme Networks to your TFIP server Verify which virtual router connects to your TFIP server Use the following ping commands to test which virtual router you will need to specify when you download the image to your s
251. xtremeFdbMacFdb MIB is not returning a fixed value PD4 634374697 If a permanent SNMP community is deleted using an earlier software release those entries are not present even after the upgrade to ExtremeXOS software which does not support deleting permanet SNMP community entries SSH and SSH2 PD3 20944751 After regenerating the SSH key you must save the configuration and then terminate SSH PD3 14620801 Terminate the SSH process using the terminate process exsshd graceful command and then restart the process using the start process exsshd command Stacking PD3 138014104 You can run the reboot stack topology command on any stacking switch while the master switch is downloading or installing an image or saving a configuration file This results in incomplete file operations before the reboot takes place which may render the image or configuration unusable Be sure that neither operation is in progress when rebooting the stack PD3 133978700 If you remove and quickly replace the stacking cable causing a separation of one or more PD3 138140417 switches from the stack the stack master may not consistently detect the missing slots PD3 137976136 The system may try to reinitialize the slots without first performing the necessary reboot Extreme Networks recommends that you wait at least five seconds between removing the cable and replacing it again PD3 119233421 VLANs can only be created if there is at least 20MB of main memory availa
252. xtremeXOS Filenames Required BootROM Version MSM G8X bd8800 12 1 4 2 patch1 8 xos 11 1 1 9 IRONIA G48Te N A 11 5 1 4 1 0 1 10 G48Pe N A 11 5 1 4 1 0 1 10 G48Ta N A 11 5 1 4 1 0 1 10 G48Xa N A 11 5 1 4 1 0 1 10 G48P N A Tal ad 1 0 1 7 G48T N A Thal todd 1 0 1 7 G48Tc N A 12 1 1 4 1 0 3 7 G48Te2 N A 12 1 1 4 ROBT G48Xc N A 12 1 1 4 1 0 3 7 G24X N A ARRES ROME G24Xc N A 12 1 1 4 ROBT G8Xc N A 12 1 1 4 1 0 3 7 10G4X N A Tal tds 1 0 1 7 10G4Xa N A TAL 6 11 S 1 0 1 11 10G4Ca N A 12 0 1 11 1 0 1 11 10G4Xc N A 12 1 1 4 ROBT 10G8Xc N A 12 1 1 4 IRORI 10G1Xc N A 12 1 1 4 1 0 3 7 PSU Controller N A Thal tld 2 1 3 700 1200 W AC PSU Model N A Mele N A 60020 PS 2336 600 900 W AC PSU Model N A 11 6 1 9 N A 41050 PS 2431 BlackDiamond 8806 only 1200 W DC PSU Model N A 11 3 2 6 N A 60021 PS 2350 MSM 48 bd8800 12 1 4 2 patch1 8 xos 11 6 1 9 1 0 1 11 MSM 48c bd8800 12 1 4 2 patch1 8 xos 12 1 1 4 1 0 3 7 a gt NOTE Upgrading the BootROM on a BlackDiamond 8810 or BlackDiamond 8806 switch is not automatic when you upgrade the software You must be running the minimum required BootROM version or later Use the install firmware command after upgrading the ExtremeXOS image to insure the BootROM is at the latest level ExtremeXOS 12 1 4 Installation and Release Notes BlackDiamond 12800 Series Switches Component Support BlackDiamond 12802 BlackDiamond 12804 BlackDiamond 12802 R Series and BlackDiamond 12804 R
253. xtremeXOS switch the software automatically moves the pointer to boot from the upgraded image before the image download is complete If the switch reboots during the upgrade install the switch will boot from a corrupt image resulting in a reboot loop PD4 454742273 PD4 415496669 The command output for the show configuration command includes enable vman port after adding a port to a vMAN which should not be included in the output PD4 463806382 PD4 457878779 Improved switch stability during rapid thrashing of IP ARP cache PD4 469891473 PD4 360515775 A loss of traffic occurs when deleting a VLAN translation member VLAN containing loopback ports Workaround If you change or delete the loopback port save and reboot the switch or disable and re enable the slot PD4 469891503 PD4 455932931 Packets are received with an incorrect tag when isolated and non isolated subscriber VLANs are added to the same port with a loopback port PD4 623659410 PD4 623659203 The xml mode process dies with signal 11 when an execConfig XML API request is received PD4 505279678 PD4 294938391 A known issue that may result in a MAC FDB polling thread to exit completely PD3 192633919 without setting the data structure to NULL after freeing memory causes a switch reboot when the data is accessed from another software thread PD4 634581903 PD4 616376561 LACP master ports are removed from a link agg
254. y 128 1 link type edge 1 edge safeguard enable 1 mode dotlid 2 cost auto 2 port priority 128 2 link type edge 2 edge safeguard enable 2 mode dotid 47 cost auto 47 port priority 128 47 link type point to point 47 edge safeguard disable 47 mode dotid 48 cost auto 48 port priority 128 48 link type point to point 48 edge safeguard disable 48 EXTREME STP NOTIFICATIONS MIB This MIB defines the following Extreme specific STP Notifications trap generated by Extreme Networks devices The following MIB is defined in extremeStp my Trap Comments extremeStpEdgePortLoopDetected port will be disabled A loop has been detected on the netlogin edge safeguard port and the ExtremeXOS 12 1 4 Installation and Release Notes Health Check Link Aggregation The following sections discuss the Health Check Link Aggregation feature Health Check Link Aggregation The Health Check LAG application allows you to create a link aggregation group where individual member links can monitor a particular TCP IP address and TCP port When connectivity to the TCP IP address and TCP port fails the member link is removed from the link aggregation group Establishing the status of a TCP connectivity is based on standard TCP socket connections As long as the switch can establish a TCP connection to the target switch and TCP port the connection is considered up The TCP connection will retry based on the configured frequency an

Download Pdf Manuals

image

Related Search

Related Contents

GE Spacemaker JVM60 User's Manual  intext:Bedienungsanleitung filetype:pdf  GUIA DO USUÁRIO - Support  Système de discussion  Canon 7D Instruction Manual  Detailed Design Specification (RRS: Rocket Recovery System)  Rollei Sportsline 90 Red  Kingston Technology HyperX 2GB 800MHz DDR2 Non-ECC Ultra Low-Latency DIMM (Kit of 2)  super B - Philippi  MARINE COMMANDER 3000  