USER`S GUIDE AIR CURTAINS

image

Contents

1. DOUBLE SPEED NFRARED REMOTE CONTROLLED WR NG DO AGRAM 8 OPERATION 8 1 Turn on the power 8 2 Select the suitable speed High Hi Low Lo 8 3 According to use adjust the grate to obtain the best effect 9 CAUTIONS a Use the unit at the rated voltage and frequency indicated on the nameplate b Disconnect power source before unit servicing c Routine maintenance must be done every year d Never use petrol benzene thinners or any other such chemical for cleaning the unit e Don t allow water or any liquid to enter the motor f When power supply comes from a socket the plug must be in accordance with IEC335 1 When the power cord is connected directly to power ensure a appropriate circuit breaker is installed to comply with local regulations
2. FM 1220S i 2000 844 270 844 4 INSTALLATION PRECAUTION Ensure to follow these directions for installation 4 1 Please install the unit in a sturdy place to avoid any shaking vibration or noise The unit should be securely fixed 4 2 Please install the unit inside the room 4 3 Don t install the unit too low no less than 2 3 meters from the ground Z Uta Ui 4 4 When the entrance is wider than the unit it is recommended to install two or more units in parallel In this case provide 20 40
3. USER S GUIDE AIR CURTAINS FM 1206SA1 FM 1206SC Y FM 1209SA1 FM 1209SC Y FM 1210SA1 FM 1210SC Y FM 1212SA1 FM 1212SC Y FM 1215SA1 FM 1215SC Y FM 1218SA1 FM 1218SC Y FM 1220SA1 FM 1220SC Y Thanks for purchasing this Air Curtain Please read these instructions carefully before use 1 PRODUCT INTRODUCTION As one of the new top class products for modern decoration air curtain is also matched with the air conditioner And it is installed at the entrances of supermarket theater meeting room hotel office room work shop and storeroom to prevent the dust mosquito and warm air and so on 2 MODEL INTRODUCTION Al FM 1209 Scy Note code of improved design of S pure metal type Al switch type C Y infrared remote control type Code of improved design 1 10 length of air curtain cm Diameter of the fan wheel cm Code of air curtain 3 IDENTIFICATION amp INSTALLATION DIMENSIONS mm FRONT 3 Z l a ie Ly mi le are B D B R O MODEL A B C D E F G H l J FM 1206S 600 30 E 550 age 50 100 215 180 105 FM 1209S 900 290 560 aad FM 1210S 1000 290 560 ws FM 1212S 1210 445 270 445 FM 1215S 1500 569 270 569 FM 1218S 1800 736 270 736
4. mm gaps between the units 20 _ 40nm IIHT a 4 5 Don t allow gaps between the unit and the wall When hanging it from the ceiling use the enclosed ceiling braskets 4 6 Don t install the unit in a place where it is splashed by water exposed to excessive steam explosive gas or corrosive gas 5 INSTALLATION A Installing against a concrete wall 5 1 1 Remove the mounting plate Undo the fixed screws on
5. the back of main body to remove the mounting plate MOUNT NG PLATE 5 1 2 Fix the bolts in the proper position Decide the position with the mounting plate CONCRETE Z Z ani Z o o g cee ao CLE Tae Z 13 15 mm 70 mm 5 1 3 Fit the mounting plate 5 1 4 Install the main body Set the main body onto the upper end of the mounting plate and clamp it as shown gt L o e NS k 4 l B Installing on a wooden or dry wall 5 2 1 Fix the mounting plate in the proper positions with tapping screw T aa w _ 7 wmnsew T lt e E fe St 5 2 2 Proceed as per step 4 above OL iia t tes L We C Hanging from the ceiling 5 3 1 Remove the mounting plate from main body Same as step 5 1 1 MOUNT NG PLATE 5 3 2 Fixing ceiling brackets as Fig 5 3 3 Set the mounting plate on the ceiling 5 3 4 Do the same as step A to install
6. the main brackets and ensure a secure fixing with use of the body bolts Using the ceiling brackets to hang from the ceiling the position of mounting plate can be ae adjusted in the limit of 100mm ee L Le LLL Li LLL ZL om r NT U 4 E H g D For above ceiling 5 4 1Fix the air curtain as in the procedure for installing on the concrete wall 5 4 2 Then pipe as per Fig 6 TECHNICAL INFORMATION Diam Max input Max air 4 Noise Air volume Net i of Volt Freq power speed 3 Dimension B h MODEL wheel V Hz W m s 05 a mm mm Hi Lo Hi Lo Hi Lo Hi Lo FM 1206S dy 115 220 50 120 115 11 8 55 53 950 700 10 600x180x215 FM 1209S y 140 135 57 55 1150 900 12 900x180x215 FM 1210S y 230 195 58 56 1750 1200 15 1000x180x215 FM 1212S Gy 230 195 58 56 1750 1200 15 1210x180x215 FM 1215S y 280 225 59 57 2180 1500 18 1500x180x215 FM 1218S y 330 250 60 58 2300 1670 25 1800x180x215 FM 1220S dy 400 270 61 59 2500 1800 28 2000 180 215 7 ELECTRICAL CONNECTION BLUE RED BLACK GREEN BLUE RED BLACK GREEN Gey i N w ee he oy 2 AA Alle MOTOR wate ao Se Poamut S _ YELLOW GREEN THERMAL OUT OUT DOUBLE SPEED SWTCH WR NG DIAGRAM