Home

Manual

image

Contents

1. The 10 100 1000Base TX and 1000Base SX LX BX Connectors 3 FUNCTIONAL DESCRIPTION 4 ASSEMBLY STARTUP AND DISMANTLING 6 PREFACE 7 TABLE OF CONTENTS 8 PRODUCT OVERVIEW 9 HARDENED GIGABIT ETHERNET SWITCH 9 PACKAGE CONTENTS 9 PRODUCT HIGHLIGHTS 10 Basic Features 10 FRONT PANEL DISPLAY 11 PHYSICAL PORTS 12 INSTALLATION 13 SELECTING A SITE FOR THE SWITCH 13 DIN RAIL MOUNTING 14 CONNECTING TO POWER 15 DC Terminal Block Power Inputs 15 CONNECTING TO YOUR NETWORK 17 Cable Type amp Length 17 Cabling 18 SPECIFICATIONS 19 EX42905 EX42914 series www etherwan com Product Overview Hardened Gigabit Ethernet Switch EX42905 PWR N b a j N N w gt E o S Put didn Ono Package Contents When you unpack the product package you shall find the items listed below Please inspect the contents and report any apparent damage or missing items immediately to your authorized reseller v This Switch v User s Manual EX42905 EX42914 series www etherwan com Product Highlights Basic Features Complies with EN61000 6 2 amp EN61000 6 4 EMC Generic standard immunity for industrial environment Supports 802 3 802 3u 802 3ab 802 3z 802 3x Auto negotiation 10 100 1000Mbps Full Half duplex Auto MDI MDIX 1000Base SX LX Multi mode SC or ST type Single mode SC or ST type 1000Base BX WDM Multi mode or Single mode SC type Supports 8192 MAC addresses 1M bi
2. BxX fiber port 12 EX42905 EX42914 series www etherwan com Installation This chapter gives step by step instructions about how to install the switch Selecting a Site for the Switch As with any electric device you should place the switch where it will not be subjected to extreme temperatures humidity or electromagnetic interference Specifically the site you select should meet the following requirements e The ambient temperature should be between 40 to 75 degrees Celsius e The relative humidity should be less than 95 percent non condensing e Surrounding electrical devices should not exceed the electromagnetic field RFC standards e Make sure that the switch receives adequate ventilation Do not block the ventilation holes on each side of the switch e The power outlet should be within 1 8 meters of the switch 13 EX42905 EX42914 series www etherwan com DIN Rail Mounting Installation Place the switch on the DIN rail from above using the slot Push the front of the switch toward the mounting surface until it audibly snaps into place Removal Pull out the lower edge and then remove the switch from the DIN rail EX42905 EX42914 series DC Terminal Block Power Inputs Step 1 Connect the DC power cord to the plug able terminal block on the switch and then plug it into a standard DC outlet Step 2 Disconnect the power cord if you want to shut down the switch The
3. connected to the Rx receive port of device Il and the Rx receive port of device to the Tx transmit port of device II 3 The WDM 1000Base BX Connections The fiber port pinouts Only one Single mode or Multi mode optical fiber is required to transmit and receive data Tx Rx Functional Description e Complies with EN61000 6 2 amp EN61000 6 4 EMC Generic standard immunity for industrial environment e Supports 802 3 802 3u 802 3ab 802 3z 802 3x Auto negotiation 10 100 1000Mbps Full Half duplex Auto MDI MDIX e 1000Base SX LX Multi mode SC or ST type Single mode SC or ST type 1000Base BX WDM Multi mode or Single mode SC type Supports 8192 MAC addresses 1M bits buffer memory Jumbo frame supported up to 10K bytes IEEE802 3az Energy Efficient Ethernet EEE supported Quality of Service QoS supported based on layer 2 priorities e Power consumption 6 5W Max 0 25A 24VDC e Power supply DC Terminal Block power input 12 48VDC 4 EX42905 EX42914 series www etherwan com e 40 C to 75 C 40 F to 167 F operating temperature range Tested for functional operation 40 C to 85 C 40 F to 185 F e Metal compact DIN Rail industrial case design EX42905 EX42914 series www etherwan com Assembly Startup and Dismantling e Assembly Place the device on the DIN Rail from above using the slot Push the front of the device toward the mounting surface until it audibly snaps into pla
4. 4 Burst Standards EN61000 4 5 Surge Standards EN61000 4 6 Induced RFI Standards EN61000 4 8 Magnetic Field Standards IEC60068 2 6 Fc Vibration Resistance IEC60068 2 27 Ea Shock FED STD 101C Method 5007 1 Free Fall w package 20
5. EX42905 EX42914 series www etherwan com Quick Start Guide This quick start guide describes how to install and use the Hardened Gigabit Ethernet Switch Capable of operating at temperature extremes of 40 C to 75 C this is the Switch of choice for harsh environments constrained by space Physical Description The Port Status LEDs EX42914 o a S A ha S vivie s G O EX42905 EX42914 series www etherwan com LED State Indication PWR Steady Device is powered up Off Device is powered off Steady A valid network connection established at 10 or 10 100 100Mbps Flashing Transmitting or receiving data 1000 Steady A valid network connection established at 1000Mbps Off The port is transferring at 10Mbps If this LED is dark The Terminal Block and Power Input The Terminal Block PWR_ Power Input GND Power Ground Earth Ground DC Terminal Block Power Input The DC Terminal Block power input can be used to power up this Switch Media Converter CAUTION This equipment is designed to permit the connection of the earthed conductor of the DC supply circuit to the earthing conductor at the equipment If this connection is made all of the following conditions must be met e This equipment shall be connected to directly to the DC supply system earthing electrode conductor or to a bonding jumper from an earthing terminal bar
6. TX 1000Base T SX LX BX Performance Cable 10Base T 100Base TX 1000Base T 100Base SX LX BX LED Indicators Dimensions Net Weight Power Operating Voltage amp Max Current Consumption Power Consumption Operating Temperature Storage Temperature Humidity EMI www etherwan com 10 100 1000Base TX auto negotiating ports with RJ 45 connectors 1000Base SX LX BX fiber port IEEE 802 3 10Base T IEEE 802 3u 100Base TX IEEE 802 3ab 1000Base T IEEE 802 3z 1000Base SX LX 10 20Mbps half full duplex 100 200Mbps half full duplex 2000Mbps full duplex 148 80pps for 10Mbps 148 810pps for 100Mbps 1 488 100pps for 1000Mbps 2 pair UTP STP Cat 3 4 5 2 pair UTP STP Cat 5 4 pair UTP STP Cat 5 Up to 100m 328ft MME 50 or 62 5um SMF 9 or10um Per unit Power status PWR Per port 10 100 1000TX 10 100 1000 1000SX LX BX 1000 30mm W x 82mm D x 114mm H 1 18 W x 3 23 D x 4 49 H 0 34Kg 0 75lb Terminal Block 12 48VDC 0 25A 24VDC 6 5W Max 40 C to 75 C 40 F to 167 F Tested for functional operation 40 C to 85 C 40 F to 185 F 40 C to 85 C 40 F to 185 F 5 95 non condensing FCC Part 15 Class A VCCI EN61000 6 4 EN55022 EN61000 3 2 EN61000 3 3 19 EX42905 EX42914 series EMS Environmental Test Compliance www etherwan com EN61000 6 2 EN61000 4 2 ESD Standard EN61000 4 3 Radiated RFI Standards EN61000 4
7. Terminal Block PWR Power Input GND Power Ground 2 Earth Ground CAUTION This equipment is designed to permit the connection of the earthed conductor of the DC supply circuit to the earthing conductor at the equipment If this connection is made all of the following conditions must be met e This equipment shall be connected to directly to the DC supply system earthing electrode conductor or to a bonding jumper from an earthing terminal bar or bus to which the DC supply system earthing electrode conductor is connected e This equipment shall be located in the same immediate area such as adjacent cabinets as any other equipment that has a connection between the earthed conductor of the same DC supply circuit and the earthing conductor and also the point of 15 www etherwan com Connecting to Power EX42905 EX42914 series www etherwan com earthing of the DC system The DC system shall not be earthed elsewhere e The DC supply source is to be located within the same premises as the equipment e Switching or disconnecting devices shall not be in the earthed circuit conductor between the DC source and the point of connection of the earthing electrode conductor 16 EX42905 EX42914 series www etherwan com Connecting to Your Network Cable Type amp Length It is necessary to follow the cable specifications below when connecting the switch to your network Use appropriate
8. cables that meet your speed and cabling requirements Cable Specifications Speed Connector Port Speed Cable Max Half Full Duplex Distance 10Base T RJ 45 10 20 Mbps 2 pair UTP STP 100 m Cat 3 4 5 100Base TX RJ 45 100 200 Mbps 2 pair UTP STP 100 m Cat 5 1000Base T RJ 45 2000 Mbps 4 pair UTP STP 100 m Cat 5 1000Base SX SC ST 2000 Mbps MMF 50 or 550 m 62 5um 1000Base SX SC 2000 Mbps MMF 50 or 2km 62 5um 1000Base LX SC 2000 Mbps SMF 9 or 10 or 20 km 10um 1000Base BX SC 2000 Mbps SMF 9 or 20 km 10um 17 EX42905 EX42914 series www etherwan com Cabling Step 1 First ensure the power of the switch and end devices are turned off lt Note gt Always ensure that the power is off before any installation Step 2 Prepare cable with corresponding connectors for each type of port lt Note gt Step 3 Step 4 Step 5 in use To connect two regular RJ 45 ports between switches or hubs you need a straight or cross over cable Consult the previous section for cabling requirements based on connectors and speed Connect one end of the cable to the switch and the other end to a desired device Once the connections between two end devices are made successfully turn on the power and the switch is operational 18 EX42905 EX42914 series Specifications Hardened Compact Switch Applicable Standards Forwarding Rate 10Base T 100Base
9. ce e Startup Connect the supply voltage to start up the device via the terminal block e Dismantling Pull out the lower edge and then remove the device from the DIN Rail 4 T EX42905 EX42914 series www etherwan com Preface A member of the growing family of rugged switches this switch addresses a need for a smaller switch This switch provides an affordable solution for rugged and outdoor environment transportation road side cabinet industrial floor shop multitenant dwellings or Fiber To The Home FTTH applications Capable of operating at temperature extremes of 40 C to 75 C this is the switch of choice for harsh environments constrained by space Plug and Play Solution The switch is a plug and play Gigabit Ethernet Switch in compact size It doesn t have any complicated software to set up This manual describes how to install and use the hardened compact Gigabit Ethernet Switch This switch integrates full wire speed switching technology This switch brings the answer to complicated hardened networking environments To get the most out of this manual you should have an understanding of Ethernet networking concepts In this manual you will find Features on the switch Illustrative LED functions Installation instructions Specifications EX42905 EX42914 series www etherwan com Table of Contents Quick START GUIDE 1 PHYSICAL DESCRIPTION 1 The Port Status LEDs 1 The Terminal Block and Power Input 2
10. or bus to which the DC supply system earthing electrode conductor is connected EX42905 EX42914 series www etherwan com e This equipment shall be located in the same immediate area such as adjacent cabinets as any other equipment that has a connection between the earthed conductor of the same DC supply circuit and the earthing conductor and also the point of earthing of the DC system The DC system shall not be earthed elsewhere e The DC supply source is to be located within the same premises as the equipment e Switching or disconnecting devices shall not be in the earthed circuit conductor between the DC source and the point of connection of the earthing electrode conductor The 10 100 1000Base TX and 1000Base SX LX BX Connectors 1 The 10 100 1000Base TX Connections The following lists the pinouts of 10 100 1000Base TX ports Pin Label TPO TPO TP1 TP2 TP2 TP1 TP3 TP3 ono HH Rw Pin Regular Ports Uplink port 1 TPO Transmit and Receive DataO 2 TPO Transmit and Receive Data 0 3 TP1 Transmit and Receive Data1 4 TP2 Transmit and Receive Data2 5 TP2 Transmit and Receive Data 2 6 TP1 Transmit and Receive Data1 7 TP3 Transmit and Receive Data3 8 TP3 Transmit and Receive Data 3 EX42905 EX42914 series www etherwan com 2 The 1000Base SX LX Connections The fiber port pinouts The Tx transmit port of device is
11. ts buffer memory Jumbo frame supported up to 10K bytes IEEE802 3az Energy Efficient Ethernet EEE supported Quality of Service QoS supported based on layer 2 priorities Power consumption 6 5W Max 0 25A 24VDC Power supply DC Terminal Block power input 12 48VDC 40 C to 75 C 40 F to 167 F operating temperature range Tested for functional operation 40 C to 85 C 40 F to 185 F Metal compact DIN Rail industrial case design 10 EX42905 EX42914 series www etherwan com Front Panel Display EX42905 EX42914 2 5 S Bhs a N TA 7 b o S ono Power Status PWR This LED comes on when the switch is properly connected to power and turned on Port Status LEDs The LEDs display status for each respective port LED State Indication PWR Steady Device is powered up Off Device is powered off Steady A valid network connection established at 10 or 10 100 100Mbps Flashing Transmitting or receiving data 1000 Steady A valid network connection established at 1000Mbps Off The port is transferring at 10Mbps If this LED is dark 11 EX42905 EX42914 series www etherwan com Physical Ports This switch provides e Five 10 100 1000Base TX ports e Four 10 100 1000Base TX ports one 1000Base SX LX BX port Connectivity e RJ 45 connectors e SC or ST connector on 1000Base SX LX fiber port e SC connector on 1000Base

Download Pdf Manuals

image

Related Search

Manual manual manualslib manual car manual timesheet manual transmission manuale digitale manually meaning manual wheelchair manual arts high school manually update your device drivers windows manual labor manual definition manual for courts martial manual muscle testing manual muscle testing grades manually register devices with autopilot manual keyboard manual blood pressure cuff manualidades manual lawn mower manual transfer switch manual transmission cars for sale manual therapy cpt code manual libs manual autopilot enrollment

Related Contents

Para juntas de 2 a 20 mm de ancho. Para el rejuntado de  Linksys E2000 User Guide  Transferir o manual de utilização  Cisco Systems Catalyst 3550 Getting Started Guide  HPD-TA 6.3, 6.4 - X-ray Micro-Imaging at SPring-8  VITOLIG 300 Bedienungsanleitung  Samsung MM-D470D Brugervejledning  ColdTech JBB-58 User's Manual  Video Test Pattern Generator DVI - VGA - Y Pb Pr  Single Port KVM over IP SWITCH USER`S MANUAL - D-Link  

Copyright © All rights reserved.