Home
        SAFEPATH facility communications system
         Contents
1.      Internal battery charger and power supply        Required batteries fit inside the enclosure  sold separately         SPB 320 requires four 12 VDC  12 AH batteries        SPB 160 and SPB 80 4 require two 12 VDC  12 AH batteries    Inputse         Audio speaker inputs  70V or 25V  field selectable        Auxiliary in  for alarm input signal     Outputse         SPB 320 has four 80 watt speaker output circuits        SPB 160 has two 80 watt speaker output circuits        SPB 80 4 has one 80 watt speaker output circuit and two 2 amp    strobe circuits  4 amps total         Supervised Audio Speaker outputs  70V or 25V field selectable     all boosters must be either 70 V or 25 V         Expansion output  supervised  24VDC at 0 5A in alarm condition     used for connecting multiple boosters        DC output  unsupervised for optional splitter power   Each speaker    circuit  four for the SPB 320  two for the SPB 160  one for the  SPB 80 4  can connect to speaker splitters     SPB 80 4 Strobe Featurese         Two 24VDC 2 amps  NAC supervised  synchronizable  power    limited  Class B strobe outputs        Selectable outputs  Wheelock sync  pass through  or constant DC        Trouble LED for open and short output conditions        Alarm indicator  LED for strobe and expansion outputs    Approvals  amp  compliances        UL Standard 864  9th edition  UL Standard 1711  California State    Fire Marshal  CSFM   New York City  MEA         OSHA 1910 165  ADA and UFC 04 021 01 2    
2.     1 year warranty    Applications        Provides for additional supervised audio power for    large installations        Provides for additional supervised and synchronizable strobe    power for large installations        Can be used in new construction as well as in retrofit construction    7    Technical Data TD001018EN    Effective October 2014    EATON www eaton com    SAFEPATH series    Table 7  Mechanical    SPB 160  SPB 80 4  Dimensions  21    H x 16    W x 6    D  wall mount     Weight  36 lbs   without batteries     Finish  Red exterior enclosure    Door Lock  Wheelock key lock    SPB 320  Dimensions  36    H x 24    W x 6    D  wall mount     Weight  80 lbs   without batteries     Finish  Red or black exterior enclosure    Door Lock  Wheelock key lock    Table 8  Ordering Information    Model Number  Order Code  Description    SPB 320  9918  320 watt supervised audio power booster  Four 80 watt circuits     SPB 320E  6336  320 watt supervised audio power booster  four 80 watt circuits   220 VAC input    SPB 320E B  6353  320 watt supervised audio power booster  four 80 watt circuits   220 VAC input  black enclosure    SPB 160  8989  160 watt supervised audio power booster  two 80 watt circuits   red enclosure    SPB 160 B  9930  160 watt supervised audio power booster  two 80 watt circuits   black enclosure    SPB 160E  6149  160 watt supervised audio power booster  two 80 watt circuits   220 VAC input    SPB 160E B  6150  160 watt supervised audio power booster 
3.    60 Hz input  E model boosters shall operate on 240 VAC  2 5A  50   60 Hz input   The SPB 80 4 or SPB 160 standby current draw shall be 120mA and alarm current draw shall be 9 amps  The SPB 320 consists of two  SPB 160   s  Each SPB 160 shall have its own power supply and battery charger  The voice frequency response shall be 400 Hz   6 5 kHz     3  dB  the BGM frequency response shall be 275 Hz   15 kHz     3 dB  Removable quick connect disconnect terminals that accept 12   22 AWG  shall be used  Multiple LED   s for easy indication of system diagnostic conditions shall be present on the PC board  The Signal to Noise Ratio  shall be  gt  70 dB  the dynamic range shall be  gt  65 dB  the Total Harmonic Distortion spec shall be 2      The booster shall be wall mountable  enclosed in a steel locking enclosure  with a red finish  Approvals for the booster shall include   UL Standard 864  9th edition  UL Standard 1711  CSFM and MEA  The system shall be OSHA 1910 165  ADA and UFC compliant  The  booster shall carry a 1 Year Warranty     The SPB 80 4  amp  SPB 160 enclosure dimensions are 21    H x 16    W x 6    D and the SPB 320 enclosure dimensions are  36    H x 24    W x 6    D     15    Technical Data TD001018EN    Effective October 2014    EATON www eaton com    SAFEPATH series    4 Zone Class B Speaker Splitter    The Wheelock SP4Z A B shall be UL Standard 864  9th edition  California State Fire Marshal  CSFM  and New York City  MEA   approved  2 Zone Class A or 4 Zone Cl
4.    SP4   RMX    SPRM  SPRM  SPRM    SP4 APS    SP4 3MEM    This drawing is for illustrative purposes only    Legend   BGM  Background Music  DV  Digital Voice Message Expander  FACP  Fire Alarm Control Panel  MPS  Pull Station  NPS  Push Station  Wheelock  Strobe Power Supplies  SP40S  Supervised Multi Function Communication System  SPB 80 4  80 Watt Audio Booster  amp  4 Amps of Strobe Power  SPB 160  160 Watt Audio Booster  SPB 320  320 Watt Audio Booster  SPRM  Remote Microphone  SP4 RMX  Remote Microphone Expansion Module  SP4 TZC  Telephone Zone Controller  SP4 APS  Addressable Paging Splitter  SP4Z A B  Speaker Splitter  SP4 SVC  Supervised Volume Control    Strobe  Speaker Speaker Strobe Cluster Speaker    DV    Volume Control    S    SPB 80 4    SP4 APS    SPB 160    SP4Z A B    SP4 APS    SPB 320    SP4 APS    SP4Z A B    SPB 160    SP4 APS    SP4 APS    Wheelock  Strobe  Power  Supply  Wheelock  Strobe  Power  Supply    SP4 APS    SP4 APS    SPB 320    SP4 APS    SP4 APS    SP4 APS    SP4Z A B    SPB 160    SP4 APS    SP4 APS    V    V    V    V    10    Technical Data TD001018EN    Effective October 2014    EATON www eaton com    SAFEPATH series    SAFEPATH Addressable Paging  Splitter and Telephone Zone  Controller    SP4 TZC  SP4 APS    SP4 APSe   Addressable paging splitter    SP4 TZC   Telephone zone controller    Features        Allows selections of speaker zones via a telephone keypad     DTMF tones         One SP4 TZC  controller  can control up to 17 SP4 AP
5.   Model Number  Order Code  Description    SP40S  9929  Multifunction supervised paging  messaging  background music and emergency voice evacuation system with 24 VDC battery  backup circuitry  single channel system with 40 watts of supervised audio power and 2 amps of supervised 24 VDC synchronized  strobe power and 8 standard messages  batteries not included  2 required    red enclosure    SP40S B  9935  Same as above but with black enclosure    SP40S PMK  9936  SP40S 8 message programmed message kit    AM SP40S SMK  9937  SP40S after market 8 message standard message kit    AM SP40S PMK  9938  SP40S after market 8 message programmed message kit    AM SP40S NBT  9939  SP40S after market narrow band signal tone kit    SP COA  9908  C O  port adapter for the SP40S or SP40 2  recommended 24 VDC power supply is Wheelock RPS 2406  Order Code 3770     SP4Z A B  9900  Supervised 2 zone Class A or 4 zone Class B speaker audio splitter for the SP40S  SP40 2 or audio boosters    SPMB4Z  9907  Mounting bracket for the SP4Z A B is required when used with the audio boosters    SPB 320  9918  320 watt supervised audio power booster  four 80 watt circuits     SPB 160  8989  160 watt supervised audio power booster  two 80 watt circuits   red enclosure    SPB 160 B  9930  160 watt supervised audio power booster  two 80 watt circuits   black enclosure    SPB 80 4  8988  80 watt supervised audio power booster with 4 amps of supervised and synchronized strobe power  two 2 amp circuits    red e
6.   Page port input    Background Music Input  13  Line Level Input  600 ohm  input voltage must be less than 2 5 V peak to peak  or 0 3 volts RMS    Table 2  Inputse  Audio Technical Specifications    Switch mode  Class D amplifier  40 Watts   Speaker Outputs  25V or 70 7V power limited    Frequency Response  Voice  275 Hz     6 5 kHz  BGM  100 Hz     15 kHz  Meets UL Voice Evacuation Requirements of  800   2800 Hz    Signal to Noise Ratio  Better than 65 dB    Dynamic Range  Better than 65 dB    Total Harmonic Distortion  Less than 2     Stand by Current Draw  130 mA    Alarm Current Draw  4 7 amps    Table 3  SP40S Mechanical    Dimensions  21    H x 16    W x 6    D  wall mount     Weight  36 lbs   without batteries     Finish  Red or black exterior enclosure    Door Lock  Wheelock key lock    4    Technical Data TD001018EN    Effective October 2014    EATON www eaton com    SAFEPATH series    Table 4  Ordering Information    Model Number  Order Code  Description    SP40S  9929  Multi Function Supervised Paging  Messaging  Background Music delivery and Emergency Voice Evacuation System with 24 VDC  battery backup circuitry  Single channel system with 40 watts of supervised audio power and 2 amps of supervised 24 VDC  synchronized strobe power and 8 standard messages   Batteries not included  2 required   Red Enclosure     SP40S B  9935  Same as above but with black enclosure    SP40SE  6138  Same as above but with 220 VAC input    SP40SE B  6139  Same as above but with 220 
7.  2 or SPB Audio Boosters        OSHA 1910 165 and ADA compliant        UFC 04 021 01    Applications        Allows manual volume setting for telephone paging and    background music for a specific speaker or speaker zone        The selected adjustment will not affect the volume setting of    emergency prerecorded messages or live microphone usage    Table 10  Ordering Information    Model Number  Order Code  Description    SP SVC  9926  Supervised volume control for use with the  SAFEPATH 4 system    SAFEPATH Remote Microphone    Description    Remote Microphone for use with the SAFEPATH 4 facility  communications system   SP40S  SP40 2 or SP4 RMX    Features        Supervised hand held push to talk microphone        Key required to enable remote microphone use        Individual front panel LED indication for  System Normal  System    Trouble and Alarm        When used with the SP40S or SP40 2  the priority level is 2  the    SP40S or SP40 2 on board microphone is always priority 1        Remote microphone usage disengages background music and    general paging        Voice frequency response  275 Hz   6 5 kHz        Requires 24VDC  supplied by the SP40S  Audio Boosters     or SP4 RMX        Input current         Standby  23mA        Alarm  30mA        Audio output level  1 05V RMS        6 wire connection to the SP40S  SP40 2 or SP4 RMX        Mounting plate is red and measures  8 3 4    x 5       fits into a 4    gang back box        All output circuitry is Power Limited   
8.  5 1 4     and shall fit into a  4 gang back box     Eaton is a registered trademark     All other trademarks are property  of their respective owners     Eaton  1000 Eaton Boulevard  Cleveland  OH 44122  United States  Eaton com    Eaton  Cooper Notification  273 Branchport Ave   Long Branch  NJ 07740  CooperNotification com       2014 Eaton  All Rights Reserved  Printed in USA  Publication No  TD001018EN  October 2014    Technical Data TD001018EN    Effective October 2014    SAFEPATH series    Remote Microphone Expansion Module    The Wheelock SP4 RMX Remote Microphone Expansion Module shall be UL Standard 864  9th edition and California State Fire Marshal   CSFM  approved for use with the SAFEPATH SP40S Facility Communications System     The SP4 RMX shall be a supervised outboard expansion module for use with the SAFEPATH system  It shall be used to expand the  number of optional supervised Remote Microphone  SPRM  modules up to three  Two SP4 RMX Remote Microphone Expansion Modules  can be connected to the SP40S or SP40 2 and shall have the capability of providing the SP40S or SP40 2 with up to six system wide    All  Call    Remote Microphone  SPRM  modulesa  The SP4 RMX can be programmed to provide either priority override for each SPRM module  input or First In First Out  First In First Out allows the active SPRM to complete its communication before another SPRM can be used  All  output circuitry shall be power limited  Multiple on board diagnostic LED indicators shall
9.  Approvals  amp  compliances        UL Standard 864  9th edition and California State    Fire Marshal  CSFM         UFC 04 021 01    Applications        Provides for an additional microphone in a remote location        Can be mounted up to 2 000 feet away from the SP40S or SP40 2    Table 11  Ordering Information    Model Number  Order Code  Description    SPRM  8996  Remote microphone for use with the  SP40S  SP40 2  SPB 320  SPB 160   SPB 80 4 or SP4 RMX  red plate    SPRM GP  9927  General paging microphone for use with  the SPB 320  SPB 160  or SPB 80 4   black plate    12    Technical Data TD001018EN    Effective October 2014    EATON www eaton com    SAFEPATH series    SAFEPATH 4 Remote Microphone  Expansion Module    SP4 RMXe  Remote microphone expansion module    Features        The SP4 RMX will provide the capability of connecting up to     3  three Remote Microphone Stations  SPRM         When connected to the SP40S or SP40 2  two SP4 RMX    units can be cascaded together to provide up to six  remote microphones        Provides for an auxiliary input for connection of an external    message repeater  for additional messages        Can accept a line level input for broadcasting of other information        When the SP4 RMX is connected to the SP40S or SP40 2  the    entire system benefits from the additional microphone capability        Can be connected to Audio Boosters for general  non alarm     paging with use of SPRM GP        Multiple on board diagnostics with 3 
10.  be provided  All wiring shall be connected to the  module using quick connect disconnect wiring terminals  capable of accepting 12   22 AWG wiring     The SP4 RMX PCB assembly is mounted in a metal enclosure measuring 13   L x 7 5 8   W x 2   D  The SP4 RMX can support each SPRM at a  range up to 2000 feet     a The SP4 RMX can also be connected to Audio Booster for general  non alarm  paging with use of SPRM GP     otee   N  Due to continuous development of our products  specifications and offerings are subject to change without notice in accordance with Eaton   s    Cooper Notification business standard terms and conditions     otee   N  Refer to the products Installation Instructions for proper installation  wiring procedures and any additional specifications     WE ENCOURAGE AND SUPPORT NICET CERTIFICATION    
11.  but not limited to  all appendices and amendments and the requirements of the local authority having jurisdiction  AHJ      5    Technical Data TD001018EN    Effective October 2014    EATON www eaton com    SAFEPATH series    Table 6  Ordering Information    Model Number  Order Code  Description    SP4Z A B  9900  Supervised 2 Zone Class A or 4 Zone Class B Speaker Audio Splitter for the SP40S  SP40 2 or Audio Boosters    SPMB4Z  9907  Mounting Bracket for the SP4Z A B is required when used with the Audio Boosters    otee   N  The Speaker Splitter Mounting Bracket  SPMB4Z  is required when the speaker splitter is used in audio boosters  The SPMB4Z can support two splitters     SAFEPATH 2 Zone Class A or 4 Zone  Class B Speaker Audio Splitter    Description        Supervised 2 zone Class A or 4 zone Class B speaker audio    splitter for the SP40S  SP40 2 or audio boosters        Enables a single supervised speaker audio output to drive up to    two Class A supervised speaker audio outputs or four Class B  supervised speaker audio outputs        For operation with SAFEPATH family of products  SP40S  SP40 2     SPB 320  SPB 160  SPB 80 4     Features        Expands one zone to up to 2 zones of supervised speaker audio    output in Class A        Expands one zone to up to 4 zones of supervised speaker audio    output in Class B        Each Class A zone can accept up to 40 watts of audio        Each Class B zone can accept up to 40 watts of audio        Operates on either 25V or 
12.  supervised audio power booster with    4 Amp of Synchronized Strobe Power        SPB 160  160 watt supervised audio power booster        SPB 320  320 watt supervised audio power booster    Live  amp  pre recorded message announcement        Supplied with 8 pre recorded emergency messages        Capable of in field recording of all messages via 1 8    line level    audio input jack        Preset audio levels for emergency messaging  prerecorded and    live mic    system reverts back to a preset level regardless of  the volume set for BGM or general paging        On board push to talk microphone        Telephone paging input  disconnects BGM when in use        Auxiliary input for remote microphone connection    Power supply  amp  batteries        24 VDC  33AH max rechargeable battery back up power    circuitry built in        Batteries can be housed in the enclosure  Up to two BAT 1212     12 volt  12 ampere hour batteries can fit in the enclosure  Actual  battery size required will depend on speaker and or strobe load    Batteries are sold separately      otee   N  All CAUTIONS and WARNINGS are identified by the symbol       All warnings are printed in bold capital letters     WARNING    PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION  INSTRUCTIONS CAREFULLY BEFORE USING  SPECIFYING OR APPLYING  THIS PRODUCT  FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS   CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION   INSTALLATION AND OR OPERATION OF THESE PRODUC
13.  supplied for message recording        A two step recording procedure is required to ensure and verify that the standard message will be permanently erased        Factory programmed messages are available for custom messages        Contact customer service for additional information        Form is required and can be downloaded from www coopernotification com    otee   N  For telephone paging  the SP40S can connect directly into the page port of the local phone system  If a page port is inaccessible  the SP COA  C O     Port Adapter for the SP40S  may be used to connect the SP40S to an unused C O  port or stand alone telephone     Wheelock products must be used within their published specifications and must be PROPERLY specified  applied  installed  operated   maintained and operationally tested in accordance with their installation instructions at the time of installation and at least twice a year or  more often and in accordance with local  state and federal codes  regulations and laws  Specification  application  installation  operation   maintenance and testing must be performed by qualified personnel for proper operation in accordance with all of the latest National Fire  Protection Association  NFPA   Underwriters    Laboratories  UL   National Electrical Code  NEC   Occupational Safety and Health Administration   OSHA   local  state  county  province  district  federal and other applicable building and fire standards  guidelines  regulations  laws and  codes including 
14.  to control and direct  telephone paging and background music zones connected to the SAFEPATH Multi Function Facility Communication System using  an RS485 connection     The Addressable Paging Splitter  SP4 APS  shall be UL Standard 864  9th edition and California State Fire Marshal  CSFM  approved   addressable and supervised 2 zone Class A or 4 zone Class B Speaker splitter  The SP4 APS shall be used with Wheelock   s SP40S or  SP40 2 panel and the Audio Booster  SPB 160  SPB 80 4  and SPB 320  panels  Each SP4 APS shall have a single audio input capable  of 25 Vrms or 70 7 Vrms at a maximum of 80 Watts  The input audio power shall be distributed to the zone connections with the total  not exceeding the input and no zone exceeding 40 Watts  When audio boosters are connected  each audio booster module shall  consume 1 2 Watts from the total input power of the SP4 APS  The splitter shall be mounted inside the SP40S  SP40 2 or Audio  Booster that it is associated with  and it shall operate on 24VDC supplied by the supported module  The SP4 APS shall contain  16 LED indicators used to monitor and troubleshoot the module     The Telephone Zone Controller Module  SP4 TZC  shall be used to address the output zones on the SP4 APS  The SP4 TZC shall be  capable of supporting 17 SP4 APS speaker splitter modules and shall be capable of addressing all zones at once     All Call      a  maximum of 68 separate zones  17 fixed zone groups and 9 programmed logical zone groups  This shall b
15.  two 80 watt circuits   220 VAC input  black enclosure    SPB 80 4  8988  80 watt supervised audio power booster with 4 amps of supervised and synchronized strobe power  two 2 amp circuits    red enclosure    SPB 80 4 B  9931  80 watt supervised audio power booster with 4 amps of supervised and synchronized strobe power  two 2 amp circuits    black enclosure    SPB 80 4E  6147  80 watt supervised audio power booster with 4 amps of supervised and synchronized strobe power  two 2 amp circuits    220 VAC input    SPB 80 4E B  6148  80 watt supervised audio power booster with 4 amps of supervised and synchronized strobe power  two 2 amp circuits    220 VAC input  black enclosure    SPMB4Z  9907  Speaker splitter mounting bracket for SPB 320  SPB 160 or SPB 80 4    otee   N  The Speaker Splitter Mounting Bracket  SPMB4Z  is required when the speaker splitter is used in audio boosters  The SPMB4Z can support two splitters     Technical specifications         120VAC  3 8A  60 Hz input        SP40SE Models 240 VAC  2 5A  50   60 Hz        Standby current draw  120mA  per amplifier board        Alarm current draw  9 amps  per amplifier board        SPB 80 4 and SPB 160 have one amplifier board        SPB 320 has two amplifier boards        System Frequency Response         Voice  400 Hz   6 5 kHz        BGM  275 Hz   15 kHz        Removable quick connect disconnect terminals     accepts 12   22 AWG        Multiple LED   s for easy indication of system diagnostic conditions        Sign
16. 20 requires 2 4 watts of audio power  to properly operate and provide  additional supervised audio output power  A combination of boosters can be added together to provide for a maximum of 5 280 watts of  supervised audio power  Additional strobe power can be obtained via a combination of boosters  The audio section of the booster shall be  connected via a selectable 70V or 25V input from the Wheelock SP40S  The strobe section of the booster shall be divided into two sections  each supplying 2 amps of 24VDC  NAC  supervised  synchronizable  power limited  Class B strobe outputs  with selectable outputs  offering Wheelock sync  pass through  or constant DC and can be activated via 8 33VDC NAC input or contact closure     The internal battery charger power supply shall be capable of charging 24 VDC batteries with a maximum capacity of 33 amp hours  The  enclosure shall be capable of housing the correct number of 12 VDC rechargeable batteries  SPB 80 4  2   SPB 160  2   SPB 320  4   with a  maximum capacity of 12 amp hours  Batteries with a larger capacity require an external battery enclosure s  such as the Cooper Wheelock  BATC or equivalent     The boosters shall have power limited circuitry and be a class D amplifier with an internal battery charger and power supply  The required  batteries  purchased separately  shall fit inside the enclosure  two 12VDC  12 AH for the SPB 80 4 or SPB 160 and four 12 VDC  12 AH for the  SPB 320   The booster shall operate on 120VAC  3 8A  50
17. 70 7V RMS        Mounts inside the enclosure of the SP40S  SP40 2 or    audio boosters        Power and Trouble LED   s        Individual zone short and open LED indication        Capable of detecting wiring faults        Removable wiring terminals for quick connect disconnect    accepting 12   22 AWG        All output circuitry is Power Limited        Space provided to allow for naming of the zones        Powered by 24VDC  supplied by the either the SP40S  SP40 2 or    audio boosters        Standby and Alarm current at 24VDC is 15mA    Approvals  amp  compliances        UL Standard 864  9th edition  and California State Fire Marshal     CSFM   New York City  MEA         UFC 04 021 01 2002    Applications        Provides for expansion of one zone to up to 2 zones of    supervised speaker audio output in Class A        Provides for expansion of one zone to up to 4 zones of    supervised speaker audio output in Class B    6    Technical Data TD001018EN    Effective October 2014    EATON www eaton com    SAFEPATH series    SAFEPATH Audio Boosters    Description    Supervised facility communication and emergency voice evacuation  audio and audio strobe power boosters  UL Standard 1711 and UL  Standard 864  9th edition with 24VDC battery backup capabilities   Designed to provide for additional supervised audio power for live  voice  pre recorded messages or background music  BGM   Fully  supervised patent pending circuitry is always in effect even during  BGM  The SPB 80 4 also pr
18. S  splitters         Telephone page input connects to stand alone telephone  unused    CO port  page port        USB connection for logical zone grouping and        BGM programming  supports Windows 2000 and Windows XP         Up to 9 logical zones   a logical zone is a user selected group of    up to 5 zones  individual or fixed         RS 485 digital control to the SP4 APS speaker splitters        Connects to the SP40S or SP40 2 via the BGM input        The combination of 1 SP4 TZC  controller  and up to 17 SP4 APS     splitters  can provide         Class B        4 zones per splitter        Up to 68 individual zones  17 splitters         17 fixed zones  groups of 4         9 logical zones        Class A        2 zones per splitter        Up to 34 individual zones  17 splitters         17 fixed zones  groups of 2         9 logical zones    SP4 TZC telephone zone controllere         Connects to the SP40S or SP40 2        Auto programmable        Custom user programmable  for logical zones         All call or selected zone s  telephone paging        Background music  BGM  zone s  selectable        Telephone input and background music  BGM  input        Enclosure for the SP4 TZC  controller          Dimensions  13   H x 7 6   W x 2 15   D        Color  Black        Wall mountable        Requires 24 VDC  model RPS 2406    SP4 APS addressable paging splittere         Addressable speaker zone splitter        Mounts inside the SP40S  SP40 2  SPB 80 4  SPB 160 or SPB 320        Ope
19. SAFEPATH facility communications  system  amp  expansion options    Contents    Description  Page    SP40S facility communications system                                                                                                    2 4  Expansion Options    SAFEPATH 2 zone Class A or 4 zone Class B speaker audio splitter                                                       5  SAFEPATH audio boosters                                                                                                                      6 7  System diagram                                                                                                                                      8 9  SAFEPATH addressable paging splitter and telephone zone controller                                                   10  SAFEPATH supervised volume control and remote microphone                                                             11  Remote microphone expansion module                                                                                            12 13    Architects and engineers specifications                                                                                                14 16    SP40S  SP4 TZC  SPB 80 4  SPB 160    SPB 320    SPRM  SP4Z A B  SP SVC  SP4 APS    Technical Data TD001018EN    Effective October 2014  Supersedes September 2011  SAFEPATH series    2    Technical Data TD001018EN    Effective October 2014    EATON www eaton com    SAFEPATH series    SAFEPATH Fa
20. TS IN AN  EMERGENCY SITUATION  WHICH COULD RESULT IN PROPERTY DAMAGE   AND SERIOUS INJURY OR DEATH TO YOU AND OR OTHERS     Benefits  amp  advantages        One multi function in building communications system        Background Music  BGM  system  with patent pending    supervision during BGM operation        Supervised emergency fire voice evacuation system        Interfaces with telephone system for general paging requirements     3    Technical Data TD001018EN    Effective October 2014    EATON www eaton com    SAFEPATH series        Built in power for visual notification appliances  e g   strobes         Expandable for larger system requirements     with optional equipment     Approvals  amp  compliances        Approvals  UL Standard 864  9th edition  UL Standard 1711     California State Fire Marshal  CSFM   New York City  MEA    FCC Part 15        OSHA 1910 165 and ADA Compliant        1 year warranty    Applications        Multi use applicationse  The system can function as an    evacuation system  an emergency messaging system  a paging  system  an employee notification system and a background music  system per NFPA 72         Fire code applicationse  The system is listed under UL Standard    864  9th edition delivering supervised audio and voice messaging  with strobes and notification appliance circuits  NAC  for visual  alerting         Economic OSHA applicationse  The system is OSHA 1910 165    compliant and therefore it does not require reliability inspections  e
21. VAC input and black enclosure    BAT 1212  7390  12 volt  12 ampere hour battery    SP40S PMK  9936  SP40S 8 Message Programmed Message Kit    AM SP40S SMK  9937  SP40S After Market 8 Message Standard Message Kit    AM SP40S PMK  9938  SP40S After Market 8 Message Programmed Message Kit    AM SP40S NBT  9939  SP40S After Market Narrow Band Signal Tone Kit    SP COA  9908  C O  Port Adapter for the SP40S     Recommended 24 VDC Power Supply is Wheelock RPS 2406  Order Code 3770     BATC R  5414  Battery Cabinet  Red    BATC B  5413  Battery Cabinet  Black    BAT 1224  7391  12 Volt  24Ampere Battery Cell    Table 5  Message Capabilities    Message and  Priority      Type of  Message  Voice Type  Message Script    1  Fire   Do not use  elevators     Male  Three  3  rounds of code 3 horn  followed by      May I have your attention please  A fire emergency has been reported in the  building  While this is being verified  please leave the building by the nearest exit  Do not use the elevators        2  Fire   Do not use  elevators     Female  Three  3  rounds of code 3 horn  followed by      May I have your attention please  A fire emergency has been reported in the  building  While this is being verified  please leave the building by the nearest exit  Do not use the elevators        3  Fire  Male  Three  3  rounds of code 3 horn  followed by      May I have your attention please  A fire emergency has been reported in the  building  While this is being verified  please leave the bu
22. al to Noise Ratio   gt  70 dB        Dynamic Range   gt  65 dB        Total Harmonic Distortion  2     8    Technical Data TD001018EN    Effective October 2014    EATON www eaton com    SAFEPATH series    SP40S    FACP    SP4   TZC    BGM  Telephone    NPS    MPS    SP4   RMX    SPRM  SPRM  SPRM    SP4 APS    SP4 3MEM    This drawing is for illustrative purposes only    Legend   BGM  Background Music  DV  Digital Voice Message Expander  FACP  Fire Alarm Control Panel  MPS  Pull Station  NPS  Push Station  Wheelock  Strobe Power Supplies  SP40S  Supervised Multi Function Communication System  SPB 80 4  80 Watt Audio Booster  amp  4 Amps of Strobe Power  SPB 160  160 Watt Audio Booster  SPB 320  320 Watt Audio Booster  SPRM  Remote Microphone  SP4 RMX  Remote Microphone Expansion Module  SP4 TZC  Telephone Zone Controller  SP4 APS  Addressable Paging Splitter  SP4Z A B  Speaker Splitter  SP4 SVC  Supervised Volume Control    Strobe  Speaker Speaker Strobe Cluster Speaker    DV    Volume Control    S    SPB 80 4    SP4 APS    SPB 160    SP4Z A B    SP4 APS    SPB 320    SP4 APS    SP4Z A B    SPB 160    SP4 APS    SP4 APS    Wheelock  Strobe  Power  Supply  Wheelock  Strobe  Power  Supply    SP4 APS    SP4 APS    SPB 320    SP4 APS    SP4 APS    SP4 APS    SP4Z A B    SPB 160    SP4 APS    SP4 APS    V    V    V    V    9    Technical Data TD001018EN    Effective October 2014    EATON www eaton com    SAFEPATH series    SP40S    FACP    SP4   TZC    BGM  Telephone    NPS    MPS 
23. ass B Speaker Splitter for operation with the Wheelock  SP40S  SP40 2  SPB 80 4  SPB 160  and SPB 320  The SP4Z A B shall enable a single supervised speaker audio output to drive up to two Class A supervised speaker  audio outputs or four Class B supervised speaker audio outputs  Each Class A zone shall be capable of accepting up to 40 watts  and operate on either 25 or 70 7V RMS of audio input  Each Class B zone shall be capable of accepting up to 40 watts of audio and  operate on either 25 or 70 7V RMS of audio input  The SP4Z A B shall be capable of supporting live microphone paging  prerecorded  emergency voice evacuation messages  supervised background music and general paging announcements     The SP4Z A B shall mount inside the enclosure of the SP40S  SP40 2  SPB 80 4  SPB 160 and SPB 320 and shall have power and  trouble LED   s with individual zone short and open LED indication  The SP4Z A B shall be capable of detecting wiring faults  The  SP4Z A B shall be powered by 24VDC  which is to be supplied by the SP40S  SP40 2  SPB 80 4  SPB 160 or SPB 320  Standby and  Alarm current at 24VDC shall be 15mA  Removable wiring terminals for quick connect disconnect accepting 12   22 AWG shall be  incorporated  All output circuitry shall be power limited  Space shall be provided to allow for naming of the zones     Addressable Paging Splitter and Telephone Zone Controller    The Wheelock Addressable Paging Splitter  SP4 APS  and Telephone Zone Controller  SP4 TZC  shall be used
24. cility Communications   SP40S    Description    The SP40S is a multifunction supervised paging  messaging   background music delivery and emergency voice evacuation  system with 24 VDC battery backup  The SP40S integrates with fire  alarm systems and provides full control of building audible and visual  notification appliances  This single channel system is capable of  delivering 40 watts of supervised high fidelity audio power and  2 amps of supervised 24 VDC synchronized strobe power  It comes  standard with an on board digital voice messaging system with  8 standard messages  a hand held microphone  power supply   battery charger and numerous additional features  The SAFEPATH  system is expandable to 5280 watts utilizing the SPB 80 4  80 watts  and 4 amps of strobe power   the SPB 160  160 watts  or SPB 320   320 watts  supervised audio power boosters  All models are  available in 115 VAC or 220 VAC     Features    Background music        Capable of broadcasting from a supplied background music     BGM  source        Unique supervision method allows for full system supervision    even during background music        Line Level input for music source        Frequency Response 100Hz   15KHz    General paging        Easily interfaces with most existing phone system page port     CO port and line level signals        Automatically mutes BGM        Frequency Response 275   6 5kHz        Night ringer or security alert connection    Voice evacuation        Complies to NFPA 72 requ
25. e accomplished using two  digit DTMF tones from a page port  an unused CO port  or a stand alone telephone with a loop start circuit  Also  the SP4 TZC shall  be able to select zones for background music  The SP4 TZC has the following inputs  Power  USB port  Background Music  BGM    Page Audio in  The outputs are  Audio out and RS485 Digital Control  The basic operating parameters of the SP4 APS shall be  pre programmed  Customized programming shall be accomplished using a USB cable and programming computer software  The  SP4 TZC shall be powered using a 24VDC filtered and regulated power supply such as the Wheelock RPS 2406  The Controller  Module assembly is mounted in a metal enclosure measuring 13   L x 7 5 8   W x 2   D     Supervised Volume Control    The Wheelock SP SVC shall be UL Standard 864  9th edition approved  supervised volume control for use with the SAPEPATH  Facility Communications System     The SP SVC shall provide for manual volume setting for telephone paging and background music for a specific speaker or speaker  zone  The selected adjustment will not affect the volume setting of emergency prerecorded messages or live microphone usage   The SP SVC shall be capable of handling up to 35 watts of audio power   70 7 volts or 4 watts audio power   25 volts and shall  operate on either 70 7 or 25 volt input from an SP40S or Audio Booster  The SP SVC shall be capable of operating in Class B or  Class A wiring configurations  for Class A  the SP4 APS is requir
26. ed   The SP SVC shall receive operating power from an Audio Booster   SP40S or SP40 2  Volume adjustment settings shall be off  1   10  in 3dB increments  The SP SVC shall be supplied with a stainless  steel mounting plate with a black knob and require a double gang  3 1 2    deep back box for mounting     Remote Microphone    The Wheelock SPRM shall be UL Standard 864  9th edition and California State Fire Marshal  CSFM  approved  Remote Microphone  for use with the SAFEPATH Facility Communications System     The SPRM shall be a supervised hand held push to talk microphone and a key shall be required to enable remote microphone  use   Same key as SP40S or SP40 2   Removable wiring terminals for quick connect disconnect accepting 12   22 AWG shall be  incorporated  All output circuitry shall be power limited  Individual front panel LED   s shall be provided for indication of System  Normal  System Trouble and Alarm  Multiple on board diagnostic LED   s shall be provided  When used with the SP40S or SP40 2   the priority level shall be number two  Remote microphone usage shall disengage background music and general paging     Voice frequency response shall be 275 Hz   6 5 kHz     2 4 dB  Power requirements shall be 24VDC and will be supplied by the  SP40S or SP40 2  Input current for Standby shall be 26mA and for Alarm 38mA  Audio output level shall be 1 05V RMA  There shall  be a 6 wire connection to the SP40S or SP40 2  The mounting plate shall be red and measure  8 3 4    x
27. eral paging   The system shall be capable of delivering 40 watts of supervised audio power and 2 amps of supervised 24 VDC synchronized strobe power   Minimum supervised audio power shall be 40 watts  expandable to 5280 watts  depending on system configuration and with additional  modules and power boosters  Supervised 24 VDC synchronized strobe power shall be 2 amps  expandable to the requirements of the  installation  The system shall be capable of operating from a 120 VAC power source  E models shall be capable of operating from a 240 VAC  power source  All models shall have a 24 VDC battery backup  Standard on board system features shall include  digital voice messaging  a  hand held push to talk microphone with override priority  and a power supply battery charger  The system shall be capable of interfacing with  telephone systems for general paging announcements and will have night ringer capabilities  Form C contacts shall be provided for system  alarm and trouble conditions     The system shall have 8 message contacts with contact closure activation  Background music input voltage shall be capable of handling  less then 2 5 V peak to peak or less then 0 3 volts  The system shall have thirteen priority ordered inputs  including  On Board Microphone   Auxiliary Input  Line Level   8 Digital Messages  Night Ringer Input  Telephone Paging Input  and Background Music Input  The system shall  have preset audio levels for emergency messaging  prerecorded and live mic   The s
28. ilding by the nearest exit        4  Emergency  Female  Three  3  rounds of code 3 horn  followed by      May I have your attention please  An emergency has been reported in the building   While this is being verified  please leave the building by the nearest exit        5  Emergency  Male  Three  3  rounds of code 3 horn  followed by      May I have your attention please  An emergency has been reported in the building   While this is being verified  please leave the building and report to the designated assembly area for your group        6  Weather  Male  Five  5  seconds of 1kHz tone  followed by      May I have your attention please  The National Weather Service has issued a severe  weather warning for our area        7  All Clear  Male  Five  5  seconds of 1kHz tone  followed by      May I have your attention please  The building emergency has ended  An all clear  has been given  Please resume normal activities        8  Test  Male  Five  5  seconds of 1kHz tone  followed by      May I have your attention please  This is a test of the Wheelock evacuation system   repeat  this is only a test            Each message can be selected to have a code 3 pre alert tone  a 1kHz continuous pre alert tone  or no pre alert tone        Post tones are also selectable and match the pre tones for individual messages        Any of the 8 messages are field programmable to record your own custom message        Each message length is 30 seconds        A 1 8    line level audio input jack is
29. irements        Supervised NAC speaker and strobe circuits        Live microphone override        8 digitally pre recorded voice messages        Uses selectable pre tones for messages    Strobe inputs and activation        2 Amps of 24 VDC supervised strobe power with built in    Wheelock sync protocol  Power limited         Strobe output is selectable for control of Wheelock sync    protocol or non sync operation        Strobe terminals have pass through capability for Wheelock    sync or non sync operation        Any of the 8 messages can be dip switch selected to    activate strobes        Microphone activation can be dip switch selected to    activate strobes        Auxiliary activation  Remote MIC  can be dip switch selected    to activate strobes        24 VDC supervised and synchronized strobe power can be    expanded to meet the requirements of the installation via  connecting to optional Wheelock power boosters    Speaker output        40 watts of supervised audio power        Speaker outputs  25V or 70 7V power limited    System activation        Contact closure message activation    Audio processing        Volume and tone controls for general paging and BGM        Connectivity of optional speaker splitter modules        Dual tone tone generator with Code 3 Tone and Slow Whoop    for alerting of system trouble        Night ringer security alerting capability        Audio power can be expanded by connecting to optional audio    power boosters        SPB 80 4  80 watt
30. l harmonic distortion  shall be less than 2      The system shall be wall mountable  enclosed in a steel locking enclosure  The required batteries for 40 watt systems shall fit inside the  enclosure  The 40 watt system shall weigh no more than 36 lbs  without batteries  and its dimensions shall not exceed 21    H x 16    W x  6    D  Approvals for the system shall include  UL Standard 864  9th edition  UL Standard 1711  FCC part 15  California State Fire Marshal   CSFM  and New York City  MEA   The system shall be OSHA 1910 165 and ADA compliant  1 Year Warranty     SAFEPATH 4 Audio Boosters    The Wheelock SPB 320  SPB 160 and SPB 80 4 Audio Boosters shall be NFPA compliant supervised audio and supervised 24VDC  synchronized strobe power boosters  some models will have supervised 24VDC synchronized strobe booster capability   The booster shall  have 24VDC battery backup capabilities  The booster shall have the capability to supervise the circuitry during playback of background  music  The booster shall have the capability to be inter connected to accommodate large installations with supervised audio power and  also supervised and synchronized strobe power requirements  Three versions of the booster shall be made available  SPB 80 4   80 watts  of supervised audio power and 4 amps of supervised and synchronized strobe power   SPB 160  160 watts of supervised audio  or SPB 320   320 watts of supervised audio      Each booster shall use 1 2 watts of audio input power  The SPB 3
31. nclosure    SPB 80 4 B  9931  80 watt supervised audio power booster with 4 amps of supervised and synchronized strobe power  two 2 amp circuits    black enclosure    SP4Z A B  9900  Supervised 2 zone Class A or 4 zone Class B speaker audio splitter for the SP40S  SP40 2  SPB 320  SPB 160 or SPB 80 4    SPMB4Z  9907  Speaker splitter mounting bracket for SPB 320  SPB 160 or SPB 80 4    SP4Z APS  9920  Addressable paging splitter    SP4 TZC  9921  Telephone zone controller    TZC USB  9923  SP4 TZC programming cable    SP SVC  9926  Supervised volume control for use with the SAFEPATH 4 System    SPRM  8996  Remote microphone for use with the SP40S  SP40 2  SPB 320  SPB 160  SPB 80 4 or SP4 RMX  red plate    SPRM GP  9927  General paging microphone for use with the SPB 320  SPB 160 or SPB 80 4  black plate    BATC R  5414  Battery cabinet  red    BATC B  5413  Battery cabinet  black    BAT 1212  7390  12 volt  12 ampere battery cell    BAT 1224  7391  12 volt  24 ampere battery cell    BAT 1265  7392  12 volt  65 ampere battery cell    14    Technical Data TD001018EN    Effective October 2014    EATON www eaton com    SAFEPATH series    Architects and engineers specifications    SP40S Facility Communications System    The system shall be a multi purpose NFPA compliant  supervised  general purpose audio  and fire emergency evacuation system  The system  shall be a single channel voice evacuation system incorporating supervision during the broadcasting of background music and gen
32. ovides 4 amps of 24 VDC supervised  and synchronized strobe power     The SPB 320  SPB 160 and the SPB 80 4 easily connects to the  Wheelock SP40S or SP40 2  Multiple SPB 320  SPB 160 and  SPB 80 4 Audio Boosters can be interconnected to accommodate  large installations with supervised audio power and also supervised  and synchronized strobe power requirements     The SPB 320 draws 2 4 watts of audio input power to properly  operate and provide additional supervised audio output power  The  SPB 160 and the SPB 80 4 draws 1 2 watts of audio input power  to properly operate and provide additional supervised audio output  power  A maximum of 5 280 watts of supervised audio power  can be achieved  Additional strobe power can be obtained via a  combination of SPB 80 4 or Wheelock power supplies chargers     SPB 80 4  SPB 160  SPB 320    SPB 320e   320 watt supervised audio power    SPB 160e   160 watt supervised audio power booster     two 80 watt circuits     SPB 80 4  80 watt supervised audio power booster with 4 amps  of supervised and synchronizable strobe power     two 2 amp circuits      Features    System Activatione  Audio        70V or 25V input from the SP40S or SP40 2        1 Volt input from SP4 RMX    System Activatione  Strobe  SPB 80 4         8   33VDC NAC input connected to the strobe input    Power supply  amp  batteries        Fully supervised patent pending circuitry always in effect even    during BGM        Power limited circuitry        Class D amplifiers   
33. rates on 24 VDC  supplied by the SP40S  SP40 2  SPB 80 4     SPB 160  SPB 320        Handles 40 watts of supervised audio per zone        UL Standard 864  9th edition listed    Approvals  amp  compliances        UFC 04 021 01    Applications        Connects to the SP40S or SP40 2 to control selectable paging and    background music  BGM         Ability to access individual or multiple speaker zones throughout    the SP40S or SP40 2 system via the telephone    Table 9  Ordering Information    Model Number  Order Code  Description    SP4Z APS  9920  Addressable paging splitter    SP4 TZC  9921  Telephone zone controller    TZC USB  9923  SP4 TZC programming cable    11    Technical Data TD001018EN    Effective October 2014    EATON www eaton com    SAFEPATH series    SAFEPATH Supervised  Volume Control    SP SVCe   Supervised volume control    Features        Supervised volume control for use with UL Listed Life    Safety Applications        Can handle up to 35 watts of 70 7 volt audio power input        Adjustment settings  0   10  in 3dB increments        Operates in Class B or Class A wiring  for Class A  the SP4 APS is    required         Requires a double gang  3 1 2    deep back box or 4    square and    1 1 2    deep box with a 1 1 2    extension ring        Stainless steel mounting plate with a black knob        Maximum RMS current 10 0mA    Approvals  amp  compliances        UL Standard 864 and California State Fire Marshal  CSFM  listed    for use with the SP40S  SP40
34. status conditions  standby     alarm  and trouble        Operates on 24 VDC  supplied by the SP40S  SP40 2  SPB 80 4     SPB 160  SPB 320        The SP4 RMX is an external module        Enclosure dimensions  13   H x 7 6   W x 2 15   D        Color  black        Wall mountable    Approvals  amp  compliances        UL Standard 864 listed        OSHA 1910 165  ADA and UFC 04 021 01    Applications        Expands one remote microphone  SPRM  from the SP40S or    SP40 2 to three remote microphones        Two SP4 RMX modules can be cascaded together to provide up    to six remote microphones from the SP40S or SP40 2        Provides for an auxiliary input for connection of an external    VoiceLink message repeater for additional messages    Table 12  Ordering Information    Model Number  Order Code  Description    SP4 RMX  9919  Remote microphone expansion module    Table 13  Microphone and message priority levels when the  SP4 RMX is used with the SP40S or SP40 2    Priority  Level  Device  Microphones    1  SP40 on board microphone    2  SP4 RMX  remote microphones  1  2  3  set priority or First In First Out    3  SP4 RMX  auxiliary input only    SP40S Standard Messages    4  SP40S message 1    5  SP40S message 2    6  SP40S message 3    7  SP40S message 4    8  SP40S message 5    9  SP40S message 6    10  SP40S message 7    11  SP40S message 8    13    Technical Data TD001018EN    Effective October 2014    EATON www eaton com    SAFEPATH series    Table 14  Ordering Information
35. very two months or the required spare parts inventory         Wide ranging applications   from small to large facilities        Can connect to pagers for private alerting of emergency     trouble conditions    Installation  amp  maintenance        Multiple trouble LED indicators for quick system diagnostics        Fully supervised circuitry always in effect   even during BGM and    general paging  via patent pending technology         Removable quick connect disconnect terminals for ease of wiring     accepts  12 to  22 AWG        Power limited circuitry with Class    B    or Class    A    wiring     Class    A    only with use of audio splitter         Surge protected circuitry        Audio and strobe power limiter reset button    Compatible Wheelock Products        All Wheelock speaker strobes        All Wheelock strobes        All Wheelock speakers        All cluster speakers        Wheelock strobe power supply    Table 1  Inputse  Audio  amp  Activation    Priority Ordered Inputs  Priority Level Type of Input    On Board Microphone  1  Push to Talk  PTT  Microphone    Auxiliary  2  Remote Microphone or Remote Microphone Expander    Digital Message Input 1  3    Contact Closure activation    Digital Message Input 2  4    Digital Message Input 3  5    Digital Message Input 4  6    Digital Message Input 5  7    Digital Message Input 6  8    Digital Message Input 7  9    Digital Message Input 8  10    Night Ringer Input  11  Contact Closure input    Telephone Paging Input  12
36. ystem shall revert back to a preset level regardless of  the volume set for background music  BGM  or general paging  Background music inputs can be an AM FM tuner  cassette  CD  MP3  or any  other remote source  The system shall be supplied with 8 pre recorded messages and be capable of in field recording of customer unique  messages  The system shall have a dual tone tone generator with Code 3 Tone and Slow Whoop  When the system is on battery power   telephone page  night ring and background music shall be disengaged     The panel shall have power limited circuitry with an internal battery charger and power supply  The power supply charger section shall be able  to charge 24 VDC batteries with a maximum capacity of 33 amp hours  Up to two 12 VDC  12 AH batteries may be housed in the enclosure   Batteries larger than 12 Ah shall be housed in a separate enclosure such as the Cooper Wheelock BATC or equivalent Batteries shall be  supplied separately     The system shall have power limited circuitry and class B wiring  Wiring terminal blocks will be removable and accept  22    12 AWG wire   Audio output voltage shall be selectable for 25V or 70 7V  The voice  live microphone or recorded message  frequency response shall be  275 Hz   6 5 kHz  background music frequency response shall be 100 Hz   15 kHz  Stand by current draw shall be 140mA  Alarm current draw  shall be 4 7 amps  The signal to noise ratio shall be better than 65 dB  dynamic range shall be better than 65 dB  tota
    