Home

NOTE

image

Contents

1. Universal Mount Rear Controls CRBR 19C ee Universal Mount Rear Controls 019 VESA Mount Only Rear Controls CVSR 19C eee VESA Mount Only Rear Controls CPSR 19C wee Flush Panel Mount Rear Controls CPBR 1905 eee Flush Panel Mount Rear Controls CPSF 17SA e eee Flush Panel Mount Front Controls CPBF 17SA Flush Panel Mount Front Controls CPSR 17SA Flush Panel Mount Rear Controls CPBR 1784 0 0000000000 Flush Panel Mount Rear Controls CFSF 17844 Flush Rack Mount Front Controls CFBF 17SA ceeeaeeeee Flush Rack Mount Front Controls Please see our web site for the latest additions and updates to the CYRAQ family CyberResearch Inc 11 25 Business Park Drive P 203 483 8815 F 203 483 9024 Branford CT USA www cyberresearch com CYRAQ 21 CyberResearch Displays 2 2 Rack Mounting CRxF CRXR 21 IMPORTANT Ask yourself these questions before beginning installation 1 Is sufficient power is available 2 Is sufficient space is available to allow for proper airflow both inside and around the display 3 Is there a possibility the air temperature inside the rack will exceed the CYRAQ 21 s rated specification Operating temperature 50 F 113 F 10 C 45 C gt NOTE Though this product is designed to operate up to 113 F 45 C with proper ventilation the life span of any electronic device is shortened when it is c
2. 3 2 6 Color Control The Color control menu allows the user to automatically add red and blue screen color adjust the gamma setting or manually adjust the red green and blue color levels To access the Color Control menu 1 Press the Menu button to access the OSD 2 Using the or button choose Color Control see Figure 28 3 Press the menu button to activate the Color Control menu 4 Choose an item on the Color Control submenu using the or button and then press Menu for example the Gamma adjustment ASE Color Control Bluish Reddish User Mode Gamma Reset Figure 28 Color Control 5 When the submenu choice appears use the or button to select adjustment see Figure 29 6 When done press Exit o SEO Color Control Gamma 1 2 3 Figure 29 Gamma Adjustment 44 OCopyright 2005 CyberResearch Inc CyberResearch Displays CYRAQ 21 3 2 7 Select Language The OSD can appear in a variety of different languages English Dutch Spanish French and several others To choose a language 1 Press the Menu button to access the OSD Using the or button choose the Language tab see Figure 28 Press the menu button to activate the Language menu Using the or button to choose desired OSD language When done press Exit So i Language ot eo IN 77 English Deutch Espanol Francois Italiano Svenska Pvccknn Figure 30 Language
3. 3 Secure the clamp to the desk bench top Figure 10 This will make subsequent installation easier The clamp is capable of securing the arm to surfaces 15 100mm thick 30mm and up is ideal 4 Before continuing remove the screw from the arm s base using a Philips head screw driver Figure 12 5 Carefully place display on the bench top with screen facing down as seen in Figure 13 F amp NOTE The SWC 100 permits 100 x 100mm VESA monitors and 75 x 75mm VESA arms to be used jointly 6 Secure the SWC 100 adapter Figure 11 to the VESA arm Figure 11 SWC 100 Adapter Mounting Plate HON oy NK HSE bed H 7 BANANA AAA AS n DATES DER gt 20 Copyright 2005 CyberResearch Inc CyberResearch Displays CYRAQ 21 Figure 12 Remove Screw 7 Secure the arm adapter plate assembly to the display VESA Arm SWC 100 8 Secure arm to the clamp with 4 flat head screws Figure 14 tighten using the L shaped hex key Rear of CYRAQ 21 FR NOTE Check arm capaci
4. Displays CYRAQ 21A Series 21 NEMA 4X Flat Panel Monitors For Rack Panel and VESA Mounting Systems with Optional AR Bonding Technology Screen Rotation Software Included USER S MANUAL VER 2 5 e OCT 2005 No part of this manual may be reproduced without permission CyberResearch Inc www cyberresearch com 25 Business Park Dr Branford CT 06405 USA 203 483 8815 9am to 5pm EST FAX 203 483 9024 CyberResearch Displays CYRAQ 21 OCopyright 2005 All Rights Reserved October 20 2005 The information in this document is subject to change without prior notice in order to improve reliability design and function and does not represent a commitment on the part of CyberResearch Inc In no event will CyberResearch Inc be liable for direct indirect special incidental or consequential damages arising out of the use of or inability to use the product or documentation even if advised of the possibility of such damages This document contains proprietary information protected by copyright All rights are reserved No part of this manual may be reproduced by any mechanical electronic or other means in any form without prior written permission of CyberResearch Inc Trademarks CyberResearch and CYRAQ 21 are trademarks of CyberResearch Inc Other product names mentioned herein are used for identification purposes only and may be trademarks and or registered trademarks of their res
5. Plug and Play Monitor Pick the monitor which you want to install CyRAQ 19 Series Analog 6 CyRAQ 24 Series Analog CyRAQ 24 Series Digital CyberResearch Inc 25 25 Business Park Drive P 203 483 8815 F 203 483 9024 Branford CT USA www cyberresearch com CYRAQ 21 CyberResearch Displays 6 Read the monitor warning Select the monitor name that exactly matches the name printed on the front of your monitor or on the back label If you select the wrong monitor restart Windows in Safe Mode and use this CD ROM or diskette again to select the correct monitor Warning Select the monitor name that exactly matches the name printed on the front of your monitor or on the back label If you select the wrong monitor restart Windows in the Safe Mode and use this CD ROM or Diskette again to select the correct monitor 7 Then Click Install 8 When the Digital Signature window appears click Yes Digital Signature Not Found xj The Microsoft digital signature affirms that software has been tested with Windows and that the software has not been altered since it was tested The software you are about to install does not contain a Microsoft digital signature Therefore there is no guarantee that this software works correctly with Windows CyRAG 21 Series If you want to search for Microsoft digitally signed software visit the Windows Update Web site at http windowsupd
6. Pivot Pro Option Menu 38 Copyright 2005 CyberResearch Inc CyberResearch Displays CYRAQ 21 3 Using the CYRAQ 21 3 1 User Controls Function Button Action OSD Off gt Launches the OSD menu and highlights Menu function displayed OSD On gt Selects menu items gt Turns the monitor on and off gt Works in conjunction with the Status light o Solid Green light indicates monitor is on o Blinking Green indicates power but no signal OSD Off gt Automatically adjust image quality to Auto optimum level OSD On gt Automatically adjust image quality to optimum level OSD Off gt Toggles the display s input between VGA Exit and DVI Source OSD On gt Backs out of currently selected menu item OSD Off gt Adjusts the brightness settings ae Ee OSD On lt Selects tabs on the OSD menu adjusts settings on the OSD menu CyberResearch Inc 39 25 Business Park Drive P 203 483 8815 F 203 483 9024 Branford CT USA www cyberresearch com CYRAQTM 21 CyberResearch Displays 3 2 Adjusting the Display 3 2 1 Auto Adjustment The Auto Adjustment feature allows users to quickly adjust the display s settings to optimum level 1 To initiate the Auto Adjust feature press the Auto button gt NOTE Expect the display to darken while a progress bar appears see Figure 22 The process will take approximately 15 seconds Auto Adjustmen
7. technique that reduces ambient light reflection inside the display case making our LCDs appear brighter even in direct sunlight CyberResearch now offers AR Bonding Technology on our entire line of signature CYRAQ LCDs which dually seals the display while significantly reducing the transmission of reflected light to it We ve accomplished this by utilizing a high quality bond that optically couples the front cover glass to the face of the display This technique practically eliminates internal light reflection which directly improves viewing quality Additionally sealing the display with AR Bonding Technology greatly enhances its structural integrity providing superior shock protection and dually eliminating the possibility of trapped moisture between the LCD and cover glass This not only reduces troublesome fogging in humid and moist conditions it keeps condensation and wetness away from your LCD Reducing the effect of ambient light reflection on your display can dramatically improve its performance When AR Bonding Technology is applied to a 250 nit display it can increase the effective contrast and provide the enhanced daylight viewing equivalent to that of a 500 or 600 nit display without AR Bonding Technology Minimizing refracted ambient sunlight to the LCD yields a discernable increase in display performance CyberResearch Inc 3 25 Business Park Drive P 203 483 8815 F 203 483 9024 Branford CT USA www cy
8. CT USA www cyberresearch com CYRAQ 21 CyberResearch Displays Intentionally Blank 70 OCopyright 2004 CyberResearch Inc CyberResearch Inc 25 Business Park Drive Branford CT 06405 USA P 203 483 8815 F 203 483 9024 www cyberresearch com
9. DDC2B The On Screen Display menu provides users with an intuitive interface making it simple to quickly adjust the display The CYRAQ 21 is the first ever 21 3 1600 x 1200 flat panel display capable of panel swivel arm or rack mounting It sets a new standard for clear bright flicker free images and its NEMA 4X front bezel makes it ideal for use in industrial environments CyberResearch Inc 1 25 Business Park Drive P 203 483 8815 F 203 483 9024 Branford CT USA www cyberresearch com CYRAQ 21 CyberResearch Displays 1 1 Why the CYRAQ 21 The CYRAQ concept was conceived in the Engineering Department at CyberResearch as we began to examine how the recent advances in LCD technology and image quality could potentially affect our market and customer base The LCD monitor today provides viewing angles comparable to CRTs with no discernable loss of picture quality a LCD resultantly provides crisp clean deep images WITHOUT screen glare Coupled with a flat screen slim design extremely low radiation and almost no electromagnetic emissions an LCD monitor can provide some very distinct advantages to users in manufacturing commercial and scientific applications Put simply the innovation of the CYRAQ series is derived from its size and applications Never before have the industrial and scientific markets been able to utilize large LCD monitors versatile enough to be rack panel or VESA arm mounted yet robust and capable
10. Next Select Controller x HAMPSHIRE COMPANY Welcome Accept HEULA La Select Controller Configure Install 10 12 BIT Serial Instructions 1 Select the controller type 2 Select controller interface type r Controller Type 12 or 10 Bit Controller 8 Bit Controller Controller Interface f Serial RS 232 Autodetect US Ps 2 mea 50 Copyright 2005 CyberResearch Inc CyberResearch Displays CYRAQ 21 8 Click Finish to install touch screen driver Configuration Complete x m Instructions Touch screen driver installation configuration is now HAMPSHIRE complete Press Finish to install the touch screen driver COMPANY Welcome Accept HEULA Select Controller Configure Install 10 12 BIT Serial COM 1 9600 bps lt Back Cancel 9 After touch screen driver is installed you will be prompted to restart the computer ARANDA Copying Common Files 10 The driver you are installing is compatible with Windows Click Continue Anyway you may need to do this more than once Software Installation 4 The software you are installing has not passed Windows Logo testing to verify its compatibility with Windows XP Tell me why this testing is important Continuing your installation of this software may impair or destabilize the correct operation of your system either immediately or in the future
11. P 203 483 8815 F 203 483 9024 Branford CT USA www cyberresearch com CYRAQ 21 CyberResearch Displays 6 After accepting the license agreement click Next Software License Agreement HAMPSHIRE COMPANY Welcome Accept HEULA Select Controller Configure Install Please read the following license agreement Press the PAGE DOWN key to see the rest of the agreement m Hampshire End User License Agreement HEULA PLEASE READ THE LICENSE AGREEMENT END USER LICENSE AGREEMENT FOR HAMPSHIRE TSHARC PRODUCT SOFTWARE IMPORTANT READ CAREFULLY This Hampshire End User License Agreement HEULS is a legal agreement between you either an individual or a single entity and Hampshire Company Inc for the Hampshire software product identified above which includes computer software and may include associated media printed materials and online or electronic documentation SOFTWARE PRODUCT The SOFTWARE PRODUCT also includes any updates and supplements to the original SOFTWARE PRODUCT provided to you by Hampshire Any software provided along with the SOFTWARE PRODUCT that is associated with a separate end user license agreement is licensed to you under the terms of that license agreement By installing copying downloading accessing or otherwise using the El accept all of the terms of the above License Agreement 7 Select controller type interface and then click
12. code CyberResearch Inc 67 25 Business Park Drive P 203 483 8815 F 203 483 9024 Branford CT USA www cyberresearch com CYRAQ 21 CyberResearch Displays Intentionally Blank 68 OCopyright 2004 CyberResearch Inc CyberResearch Displays CYRAQ 21 Warranty Notice CyberResearch Inc warrants that this equipment as furnished will be free from defects in material and workmanship for a period of one year from the confirmed date of purchase by the original buyer and that upon written notice of any such defect CyberResearch Inc will at its option repair or replace the defective item under the terms of this warranty subject to the provisions and specific exclusions listed herein This warranty shall not apply to equipment that has been previously repaired or altered outside our plant in any way which may in the judgment of the manufacturer affect its reliability Nor will it apply if the equipment has been used in a manner exceeding or inconsistent with its specifications or if the serial number has been removed CyberResearch Inc does not assume any liability for consequential damages as a result from our products uses and in any event our liability shall not exceed the original selling price of the equipment The equipment warranty shall constitute the sole and exclusive remedy of any Buyer of Seller equipment and the sole and exclusive liability of the Seller its successors or assigns in connect
13. point Please reference our web site for the latest and most complete details on each card 1 GRIAGP64 AGP VGA Graphics card with 64MB DDR VRAM Single Output 2 GRI PCI32 PCI SVGA Graphics Card with 32MB VRAM 3 GRIAGPD128 VGA AGP Graphics Card with Dual DVI or VGA 128MB DDR Dual t ual Outpu SDRAM 4 GRIAGPT128 AGP Parhelia Triple VGA Graphics Card with 3 RGB Outputs 2 Triple Output DVI Outputs TV Output 128MB DDR VRAM 5 GRI AGPT256 AGP Parhelia Triple VGA Graphics Card with 3 RGB Outputs 2 DVI Outputs TV Output 256MB DDR VRAM CyberResearch Inc 9 25 Business Park Drive P 203 483 8815 F 203 483 9024 Branford CT USA www cyberresearch com CYRAQ 21 CyberResearch Displays 2 Setup 2 1 Unpacking the CYRAQ 21 Before unpacking it is very important to locate the CYRAQ monitor in a suitable environment Make sure the installation location has good ventilation is out of direct sunlight away form excessive dust dirt heat water moisture and vibration Please see Specifications section for environmental details 2 1 1 Your Package Contains 1 2 3 4 5 6 7 8 9 A CYRAQ Series Display CYRAQ Series Drivers amp Manuals CD Pivot Pro Installation CD optional 6 ft Power Cable 6 ft VGA and DVI cables User s Manual Universal Mounting Plate CRMS UNL applies to landscape Rack Mount and Panel Mount Applications only or Portrait Mounting plate CRMS POR applies t
14. then clean the LCD screen to reduce abrasion from the cleaning applicator gt Do not use or store flammable substances near the monitor 60 Copyright 2005 CyberResearch Inc CyberResearch Displays CYRAQ 21 5 1 3 Fan Filters Periodically you may find it necessary to clean fan filters built into the back of the CYRAQ s enclosure Cleaning frequency is largely based on environmental and other conditions immediately surrounding the unit Since most applications require the CYRAQ to be rack or panel mounted the engineers at CyberResearch Inc designed a filter system users can maintain without dismounting the display disassembling the unit or removing the fan filters from the enclosure Disconnect power to the unit before beginning the subsequent steps To clean the fan filters 1 Power off the unit using the On Off switch 2 Unplug the unit s AC power 3 Gain access to the rear of the unit 4 Carefully run a vacuum hose using a crevice attachment is ideal over the protective fan filter screens Figure 40 to remove dust and debris from the protective covers and underlying fan filters themselves 5 When done restore power to unit Fan Filter Screens LOL IA INI FTP TEE TN AN HI Coe HE HN Figure 40 Cleaning Fan Filters CyberResearch Inc 61 25 Business Park Drive P 203 483 8815 F 203 483 9024 Branford CT USA www cyberresearch com CYRAQTM 21 CyberResearch Displays 6 Me
15. will be prompted to restart your computer 1 Insert the Drivers amp Manuals CD into your CD drive 2 When the splash screen appears choose Install Drivers INSTALL DRIVERS E YRAQ Series V2 8B a i Software Drivers amp Utilities VIEW MANUALS gt VIEW OUR WEBSITE 2 3 CyberResearch Branford Connecticut USA 28 OCopyright 2005 CyberResearch Inc CyberResearch Displays CYRAQ 21 3 Choose Magic Rotation de INSTALL PRODUCTS TOUCHSCREEN CDISPLAY DRIVERS a a lt lt UTILITY S W gt Product Magic Rotation Software 5 E _ omer ROTATION Version N A q N Compatibility Win9X ME 2K XP Lu Please click the button to install the Magic Rotation software for your CyRAQ unit NOTE Some versions of CyRAQ units will only work with Magic Rotation and not PivotPro Please use the correct rotation software that was packaged with this product CyberResearch MAIN MENU Branford Connecticut USA 4 Then choose your operating system 4 am E MAGIC ROTATION WIN 9X ME a 2 E E WIN 2K XP Welcome to the Magic Rotation Software section Please click on a button to the left for the installer that corresponds to your Operating System NOTE To determine the operating system on your computer click the START button on your desktop and you will see the version you have written vertically on the start
16. you are prepared for the call To ensure your call s overall success and expediency 1 Have the phone close to the PC so you can conveniently and quickly take action that the Applications Engineer might suggest 2 Be prepared to open your PC remove boards report back switch or jumper settings and possibly change settings before reinstalling the modules 3 Have a volt meter handy to take measurements of the signals you are trying to measure as well as the signals on the board module or power supply 4 Isolate problem areas that are not working as you expected 5 Have the source code to the program you are having trouble with available so that preceding and prerequisite modes can be referenced and discussed 6 Have the manual at hand Also have the product s utility disks and any other relevant disks nearby so programs and version numbers can be checked Preparation will facilitate the diagnosis procedure save you time and avoid repeated calls Here are a few preliminary actions you can take before you call which may solve some of the more common problems 1 Check the PC bus power and any power supply signals 2 Check the voltage level of the signal between SIGNAL HIGH and SIGNAL LOW or SIGNAL and SIGNAL It CANNOT exceed the full scale range of the board 3 Check the other boards in your PC or modules on the network for address and interrupt conflicts 4 Refer to the example programs as a baseline for comparing
17. 2005 CyberResearch Inc CyberResearch Displays CYRAQ 21 4 2 4 Calibration Test This is the last screen displayed in the calibration process 1 Touch the screen and notice if the calibration target is displayed under your finger or stylus If the target appears directly under your finger select the Accept button 2 Ifthe target does not appear directly beneath your finger or stylus select the Cancel button reconfigure your calibration options and recalibrate until you get an acceptable calibration You may adjust the Offset or try a different calibration scheme 3 Select Accept to apply and record your calibration data 4 Select Cancel to return to the calibration tab Once you return to the calibration tab select OK or Apply to save your settings 5 Ifyou have multiple monitors return to the Screen Selection tab and select another monitor to calibrate Touch the screen n verity the target moves to your finger Figure 37 Calibration Target CyberResearch Inc 55 25 Business Park Drive P 203 483 8815 F 203 483 9024 Branford CT USA www cyberresearch com CYRAQ 21 CyberResearch Displays 4 2 5 Drawing Test Use the Test Feature to ensure calibration is accurate Once you have calibrated your touchscreen you may select the Test button located on the calibration tab of the control panel This is a simple drawing program that you may use
18. 489mm W for landscape installation Figure 7 2 Install the display in panel cut out Ensure all studs clear cutout opening and Poron gasket on the rear of the unit is flush against panel critical for NEMA compliance F amp NOTE Steps 3 amp 4 require a second person 3 Align studs on the rear of display with the holes in mounting plate from the rear of panel as seen in Figure 7 Important Do not exceed 30 in lbs when tightening mounting nuts 4 Also from rear of the panel second person must install and tighten the fourteen 10 32 mounting nuts See Next Page For Illustration 18 Copyright 2005 CyberResearch Inc CyberResearch Displays CYRAQ 21 Figure 7 Flush Panel Mount Landscape Installation CyberResearch Inc 19 25 Business Park Drive P 203 483 8815 F 203 483 9024 Branford CT USA www cyberresearch com CYRAQ 21 CyberResearch Displays 2 5 VESA Mounting CVBF CVBR 21 R gt NOTE These are Quick Install instructions for a popular style bench top mount VESA arm This VESA arm style MAY NOT be the mounting choice you ve selected for your CYRAQ Check the documentation accompanying your VESA arm 1 Disconnect the power video and touchscreen cables 2 Secure cranking unit 1 to bracket 2 with at least two bolts Figure 9 The use of bolts and bolt position depends on thickness of desk Fully secure bolts with included T type hex key
19. 9 61 Display and Enclosure adi a e a 3 ad al 62 Landscape Mounting Plate Dimensions 63 Figure 43 Portrait Mounting Plate Dimensions enma nenea aaa n 64 vii CyberResearch Inc 25 Business Park Drive Branford CT USA P 203 483 8815 F 203 483 9024 www cyberresearch com CYRAQ 21 CyberResearch Displays viii OCopyright 2005 CyberResearch Inc CyberResearch Displays CYRAQ 21 1 Introduction Congratulations on your purchase of the most innovative and versatile Industrial LCD monitor available today the CYRAQ 21 The CyberResearch CYRAQ 21 uses a groundbreaking raised bezel design allowing the installation of a rugged 21 3 flat panel display in a standard EIA 19 rack The engineers at CyberResearch have also designed mounting plates that allow the CYRAQ 21 to be rack or panel mounted in either landscape or portrait orientation The accompanying screen rotation software rotates the desktop 90 180 or 270 to provide a suitable viewing angle for any display orientation The CYRAQ 21 complies with the power management regulations of VESA DPMS making it extremely energy efficient 75W while active and 3W in power saving mode The CYRAQ 21 LCD monitor emits very low radiation levels and virtually no electromagnetic field Fully compatible with the PC and Macintosh the CYRAQ 21 provides dual inputs VGA and DVI is Plug amp Play compatible and also complies with DDC1
20. E PRODUCT is protected by both copyright law and computer program protection laws 1 GRANT OF LICENSE This EULA grants you the following rights Software Installation and Use SAMSUNG ELECTRONICS grants you the right to install and use the SOFTWARE PRODUCT on your single computer running under a legally acquired operation system v accept the terms of the license agreement Y do not accept the terms of the license agreement lt Back Nem crea 8 Choose the location for Setup to install the files You can accept the default location C Program Files or choose an alternate location via the Change button When done click Next Install Shield Install MagicRotation to C Program Files CyberResearch Inc 25 Business Park Drive Branford CT USA 31 P 203 483 8815 F 203 483 9024 www cyberresearch com CYRAQ 21 CyberResearch Displays 9 Before the installation begins you re given the opportunity to go back to any of the configuration choices you ve made and make changes When done click the Install button to begin the installation process n InstallShield Wizard x agicRe Magick Ready to Install the Program Tk ard is 1 Click Install to begin the installation If you want to review or change any of your installation settings click Back Click Cancel to exit the wizard InstallShield 10 A progress bar appears as the installation is co
21. Menu 3 2 8 Customize OSD Menu The OSD itself can be customized It can be set to appear anywhere on your display The menu color and tone can be adjusted along with the setting for how long the OSD appears onscreen As an example of how to use one of the customizing features of the OSD menu follow these steps to adjust the vertical position of the menu 1 Press the Menu button to access the OSD 2 Using the or button choose the OSD tab see Figure 31 3 Press the menu button to activate the OSD menu OSD Operation Tip When the Horizontal or Vertical position of the OSD is changed it becomes the default location for the menu to appear CyberResearch Inc 45 25 Business Park Drive P 203 483 8815 F 203 483 9024 Branford CT USA www cyberresearch com CYRAQTM 21 CyberResearch Displays To adjust the position of the OSD 4 5 6 4 Use the or button to select the H Position horizontal adjustment Press Menu to select When the H Position submenu appears use the or button to move the menu to the desired location When done press Exit 6 DBO Language H Position V Position Halftone Duration Color Figure 31 OSD Menu 3 2 9 Source Select The Source button on the display is controlled by two choices that reside within the Source Select tab on the OSD menu Auto and Manual Users have the option of allowing their display to search for an input automatically or to ma
22. Microsoft strongly recommends that you stop this installation now and contact the software vendor for software that has passed Windows Logo testing STOP Installation CyberResearch Inc 51 25 Business Park Drive P 203 483 8815 F 203 483 9024 Branford CT USA www cyberresearch com CYRAQTM 21 CyberResearch Displays 11 Click OK Touch Screen Controller Setup Rev 6 18f Setup is now complete ER 12 Restart your computer before continuing with section 4 2 4 2 Calibration 4 2 1 Calibration Options Three point calibration Quick calibration of a known good touchscreen overlay May be used to evaluate test or verify actual touchscreen linearity No correction Four Point Calibration Default Will compensate for skew and some edge linearity anomalies Best for general calibration Seven Point Calibration More accurate than 3 point calibration Helps calibrate screen to the edges No correction Twenty Point Calibration Provides the highest level of touchscreen linearization and skew correction Should be used to get the best possible calibration May be used to extend the life of a failing touchscreen Calibration Offset Because of the varied linearity that exists between touchscreen types you may want to calibrate the edges of the touchscreen more precisely Experiment with this setting to find the best result Default is 20 Select the large target to calibrate 4 2 2 Con
23. Panel cutout is 356mm H x 440mm W for landscape installation Figure 6 2 Install CYRAQ in panel cutout Ensure all studs clear cutout opening and Poron gasket on the rear of the unit is flush against panel critical for NEMA compliance NOTE Steps 3 amp 4 require a second person 3 Align studs on the CYRAQ with the holes in mounting plate from the rear of panel as seen in Figure 6 Important Do not exceed 30 in lbs when tightening mounting nuts 4 Also from rear of the panel second person must install and tighten the fourteen 10 32 mounting nuts PIale nting si y pan e Gasta 4 lt lt pispley 2 e e Figure 6 Panel Mount Landscape Installation CyberResearch Inc 17 25 Business Park Drive P 203 483 8815 F 203 483 9024 Branford CT USA www cyberresearch com CYRAQ 21 CyberResearch Displays 2 4 Flush Panel Mounting CPxF CPxR 21A Prior to performing subsequent steps ensure the panel mounting location including panel thickness is suitable for the CYRAQ 21 and meets Environmental requirements in Specifications section R gt NOTE Panel thickness should not exceed 55 14 1mm Suggested panel thickness is calculated based on standard CYRAQ 21 parts and dimensions custom units may not meet these specifications Poron gasket is installed by CyberResearch Inc on CPBF amp CPBR 21 models 2 4 1 Panel Mounting the Monitor 1 Panel cutout is 405mm H x
24. a compact corrosion resistant enclosure of heavy duty stainless steel 304 SS All models come with a water resistant sealed front panel suitable for washdown Built in Poron gasket seals between rear of display and user panel or rack mounting plate When properly mounted in an appropriate enclosure these displays meet NEMA 4X standards for watertightness Models CVSF 21A and CVBF 21A designed for VESA swivel arm mounting do not include rear studs gasket or a mounting plate but CVxx customers receive a 75 credit toward purchase of a swivel arm on request The glass front panel is of high light transmission tempered glass Units without touchscreen feature antireflection antiglare hard coat glass screens May be ordered with user controls for OSD and display power on the front or rear 100x100mm VESA mounting holes e Enclosure can be rack panel wall or swivel arm mounted e Universal mounting plate facilitates mounting in a standard EIA 19 rack or can be used behind panel for secure panel mounting e Optional portrait rack mounting plate substituted on request lets you rack mount display in portrait orientation screen rotation software included Copyright 2005 CyberResearch Inc CyberResearch Displays CYRAQ 21 Indicators Switches amp Controls OSD Controls Brightness Contrast Front Panel Controls Other Controls Features Rear panet Power On Off Switch Controls Indicators Pow
25. ate microsoft com to see if one is available Do you want to continue the installation L No More Info 9 When the driver has been installed a Monitor Setup message will appear click OK CyRAQ Monitor Setup x The Monitor has been successfully installed 26 Copyright 2005 CyberResearch Inc CyberResearch Displays CYRAQ 21 R gt NOTE If the CYRAQ doesn t display an image immediately move the mouse to awaken it from Suspend mode R gt NOTE If an image still isn t displayed toggle the Exit Source button to ensure the correct input is being used CyberResearch Inc 27 25 Business Park Drive P 203 483 8815 F 203 483 9024 Branford CT USA www cyberresearch com CYRAQ 21 CyberResearch Displays 2 8 Screen Rotation Software The CYRAQ Series of displays comes with software that allows users to rotate their desktop to 0 90 180 and 270 degrees This software is essential if mounting the CYRAQ in a position other than landscape If you package contains just one CD the CYRAQ Series Drivers amp Manuals CD MagicRotation software has been bundled with your product please proceed with MagicRotation Installation instructions Important If your package includes a Pivot Pro Installation CD skip to 2 8 3 Pivot Pro Installation 2 8 1 MagicRotation Installation gt NOTE Close all unnecessary applications before continuing at the end of this procedure you
26. berresearch com CYRAQ 21 CyberResearch Displays 1 3 Product Safety and Regulatory Information To prevent fire or shock hazard do not expose the unit to rain or moisture Dangerously high voltages are present inside this unit Do not disassemble the unit there are no user serviceable components inside the monitor s enclosure Please contact CyberResearch Inc for repair This equipment is not intended for use in critical applications where its failure to operate would create immediate life threatening circumstances Applications including but not limited to nuclear reactor control aerospace navigation systems and life support systems are not appropriate for this product The CYRAQ 21 should be mounted in a suitable cabinet or enclosure The NEMA rating for this product is applicable only when the product is properly set up and installed FCC Notice The Federal Communications Commission Radio Frequency Interference Statement includes the following warning This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guara
27. chanical Drawings Figure 41 Display and Enclosure Dimensions 62 OCopyright 2005 CyberResearch Inc CyberResearch Displays CYRAQ 21 3220 3952 PER g902s TE 56 z Figure 42 Landscape Mounting Plate Dimensions 63 P 203 483 8815 F 203 483 9024 www cyberresearch com CyberResearch Inc 25 Business Park Drive Branford CT USA CYRAQTM 21 CyberResearch Displays CyberResearch Inc Rack21 Confidential MTG Plate Vert 3 1 10 02 03 pg 10 Thickness 0 10 SS Figure 43 Portrait Mounting Plate Dimensions 64 OCopyright 2004 CyberResearch Inc CyberResearch Displays CYRAQ 21 Intentionally Blank CyberResearch Inc 65 25 Business Park Drive P 203 483 8815 F 203 483 9024 Branford CT USA www cyberresearch com CYRAQ 21 CyberResearch Displays 66 Copyright 2004 CyberResearch Inc CyberResearch Displays CYRAQ 21 Product Service Diagnosis and Debug CyberResearch Inc maintains technical support lines staffed by experienced Applications Engineers and Technicians There is no charge to call and we will return your call promptly if it is received while our lines are busy Most problems encountered with data acquisition products can be solved over the phone Signal connections and programming are the two most common sources of difficulty CyberResearch support personnel can help you solve these problems especially if
28. ctive 3W in power saving mode 3 cooling fans 3 60mm X 60mm Rear Rear 50 F 113 F 10 C 45 C 4 F 122 F 20 C 50 C 10 80 30g half sine for 11ms 15 to 57Hz 0 006 peak to peak 57 to 640Hz sine 1 0g peak to peak 1 89mi 3 05km EPA Energy Star compliant DPMS Display Power Management Signaling CyberResearch Inc 25 Business Park Drive Branford CT USA 7 P 203 483 8815 F 203 483 9024 www cyberresearch com CYRAQ 21 CyberResearch Displays Dimensions Width 19 02 483 mm Height 15 71 399 mm Depth 3 1 79 mm Width Rack Mount EIA standard 19 inches at flanges Height Rack Units 9U 15 75 Depth Behind Panel 1 5 38 mm Depth In Front of Panel 1 6 41 mm Max Protrusion from Panel w installed gasket 1 7 43 mm Panel Mount Cutout Width Panel Mount Cutout Height Maximum Panel Mount Cutout Depth Dimension Details Weight Weight Display Filter Weight 17 3 440 mm 14 0 356 mm 55 14 mm e Bezel Depth in Front of Panel 1 6 gasket thickness e Gasket Depth 0 125 uncompressed Mounting Adapter Plate Depth 0 1 Rack Height in Portrait View 19 2 11U 24 03 Ibs 10 9kg Under 30 lbs OCopyright 2005 CyberResearch Inc CyberResearch Displays CYRAQ 21 1 5 Features 1 5 1 Overview The CyberResearch CYRAQ 21 is a 21 3 inch analog digital LCD monitor that offers the highest quality images possible with d
29. enough to perform in harsh environments The CYRAQ stainless steel enclosure not only provides an unmatched degree of protection to the unit s components it dually helps achieve a NEMA 4X rating capable of sustaining normal operation when installed correctly while enduring screen washdown and other procedures commonly practiced in a harsh environment The CyberResearch Inc CYRAQ series displays have been engineered to couple with a revolutionary new mounting plate system that allows a user to install the CYRAQ display into a rack or a panel without retrofitting disparate hardware drilling holes or welding mounting studs The mounting plate systems make it a snap to install a CYRAQ into a standard 19 rack or panel mount in any orientation Currently the CYRAQ family is comprised of many many models including displays featuring rear controls only VESA mounting choice of color and touchscreen serial or USB available CyberResearch has also expanded the CYRAQ family to include the CYRAO 12 12 CYRAO 15 15 CYRAO 17 17 in addition to 19 21 amp 24 models please call us or visit our website for more information 2 OCopyright 2005 CyberResearch Inc CyberResearch Displays CYRAQ 21 1 2 CyberResearch AR Bonding Technology Standard LCDs used in bright ambient light may appear washed out due to excessive reflection from these lighting conditions CyberResearch has developed a manufacturing
30. er Installation 1 Insert the driver CD into the computer s CD drive 2 When the splash screen appears select Install Drivers CyRAQ Series V2 3 Software Drivers amp Utilities N q VIEW MANUALS y DATASHEETS BROWSE CONTENTS 4 CONTACT US Figure 17 Splash Screen 3 When the Install Products window appears click Display Drivers 4 M INSTALL PRODUCTS TOUCHSCREEN SS S ois SPLAY DRIVERS 2 Please click the button to install the CyRAO display a p 4 drivers for your CyRAQ unit UTILITY 8 Product CyRAQ Display Drivers Version 1 00 Compatibility Win 9IX ME2K XP ETE CyberResearch ranford Connecticut 24 Copyright 2005 CyberResearch Inc CyberResearch Displays CYRAQ 21 4 Then click on your operating system MW DISPLAY DRIVERS Welcome to the Display Driver section Please click on a button to the left for the installer that corresponds to your Operating System NOTE To determine the operating system on your computer click the START button on your desktop and you will see the version you have written vertically on the start menu that appears 5 Select CYRAQ 21 and click OK CyRAQ Monitor Setup for Windows 2000 xl Pick the display adapter on which you want to install the monitor Matrox Millennium G450 DualHead LE English Currently installed monitor T
31. er On Off Signal Connectors Video Input Connectors Cables Video Cable Length included Cabling Details Power Supply Power Supply Form Factor Nominal Input Voltage s Input Voltage Range s Input Frequency Power Supply Input Connector Power Consumption Power Consumption Details Cooling Cooling Summary Number of Fans of This Type Fan Size Fan Location s Cooling Fans Air Filter Location Environmental Specifications Operating Temperature Storage Temperature Relative Humidity non condensing Shock Resistance Operating Vibration Operating Resistance Altitude Max Safety amp Standards Compliance Power Management OSD controls for menu navigation 5 buttons Via OSD controls Via OSD controls e Auto Button One touch automatic screen adjustment e Exit Button Quits OSD menu switches between analog or digital signal inputs when the OSD menu is off e Button Increase decrease item selected in OSD menu e Order models CRSF 21A CRBF 21A CVSF 21A or CVBF 21A for sealed front access OSD control buttons e Order models CRSR 21A or CRBR 21A for rear access OSD control buttons 1 on off switch LED indicates power on HD15 standard VGA connector DVI D 24 pin connector 6 feet 15 pin D sub VGA DVI D and AC power cables included 6 ft each Built in integral 115 230VAC 90 264VAC 50 60Hz On rear panel NEMA standard male PC cord socket w 6 ft USA power cord 75W a
32. figure Calibration Settings Generally speaking the default setting of 4 Point Calibration is quite accurate for most applications It is recommended the user try this default setting before configuring calibration with a different setting If adjustments need to be made use the procedure on the next page 52 Copyright 2005 CyberResearch Inc CyberResearch Displays CYRAQ 21 1 Open the Hampshire TSHARC Control Panel Star All Programs Hampshire TSHARC Control Panel Click the Calibration tab Hampshire TSHARC Control Panel Rev 6 18f Screen Selection Calibration Click Settings Touch Settings Capacitive gt Touch or click the calibration target to calibrate the touch screen Administrator Access is Required Configure Test Configure the calibration type Test touch screen calibration and offset x Les 2 Click touch on the Configure button Calibration Options Select Calibration Type and Offset Offset 3 Point 4 Point Calibration Calibration C 10 C 15 7 Point 20 Point Calibration Calibration 20 3 When the Calibration Options window appears a Click touch on a Calibration Type icon AND b Choose an Offset radio button 4 Then click touch OK CyberResearch Inc 53 25 Business Park Drive P 203 483 8815 F 203 483 9024 Branford CT USA www cyberresearch com CYRAQTM 21 CyberResearch Displays 4 2 3 Calibration Rou
33. ght 2005 CyberResearch Inc CyberResearch Displays CYRAQ 21 4 Then click TouchScreen Figure 35 0 w INSTALL PRODUCTS TOUCHSCREEN 2 Please click the button to install the TSHARC 2 A y touchscreen drivers for your CyRAQ unit UTILITY S W Product Cyber Resistive Touchscreen Drivers 3 e amp 7 Version 6 15 Compatibility Win9X ME 2K XP 1 Controller interface RS 232 USB PS 2 O 6 berResearch Figure 35 Install Products 5 After the Welcome window appears click Next to continue A HAMPSHIRE Welcome to the TSHARC touch screen controller driver Setup COMPANY The Setup program for the Hampshire TSHARC controllers for Microsoft Windows Each Setup dialog has instructions for Welcome completing a step of the installation To install the Hampshire TSHARC controller driver now click Accept HEULA Next or press Enter Select Controller To exit Setup without installing the Hampshire TSHARC controller driver click Cancel at any time Configure Install Warming This computer program is protected by copyright law and international treaties Unauthorized reproduction or distribution of this program or any portion of it may result in severe civil and criminal penalties and will be prosecuted to the maximum extent possible under the law Rev 6 15 1995 2004 Hampshire Company Inc lt Back Cancel CyberResearch Inc 49 25 Business Park Drive
34. ion with equipment purchased and in lieu of all other warranties expressed implied or statutory including but not limited to any implied warranty of merchant ability or fitness and all other obligations or liabilities of seller its successors or assigns The equipment must be returned postage prepaid Package it securely and insure it You will be charged for parts and labor if the warranty period has expired Returns and RMAs If a CyberResearch product has been diagnosed as being non functional is visibly damaged or must be returned for any other reason please call for an assigned RMA number The RMA number is a key piece of information that lets us track and process returned merchandise with the fastest possible turnaround time PLEASE CALL FOR AN RMA NUMBER Packages returned without an RMA number will be refused In most cases a returned package will be refused at the receiving dock if its contents are not known The RMA number allows us to reference the history of returned products and determine if they are meeting your application s requirements When you call customer service for your RMA number you will be asked to provide information about the product you are returning your address and a contact person at your organization Please make sure that the RMA number is prominently displayed on the outside of the box Thank You CyberResearch Inc 69 25 Business Park Drive P 203 483 8815 F 203 483 9024 Branford
35. it the control panel 58 Copyright 2005 CyberResearch Inc CyberResearch Displays CYRAQ 21 4 2 7 Touch Settings Touch Sound Check Enable touch sound to enable a beep when the touchscreen is touched Normal Emulates a standard mouse Selecting Normal will allow for singleclick double click drawing dragging and right click option if right click is enabled Touch down Touch down will allow for a click event to take place at touch down You will not be able to draw or drag if this option is selected Touch up Touch sent only at touch up Disables right click and double click functions Click or touch Apply to apply your selection OK to apply and exit the control Hampshire TSHARC Control Panel Rev 6 18f Screen Selection Calibration Click Settings Touch Settings Capacitive Touch Mode Enable touch sound fe Normal All features are available default Touch down Touch sent only at touch down All other features are available Touch Up Touch sent only at Touch Up This disables the right mouse click option Figure 39 Touch Settings Tab CyberResearch Inc 59 25 Business Park Drive P 203 483 8815 F 203 483 9024 Branford CT USA www cyberresearch com CYRAQ 21 CyberResearch Displays 5 Product Care The CYRAQ unit is basically a maintenance free product It does require occasional cleaning to keep 1t looking and performing its best Additiona
36. lly please make sure the unit is placed with consideration for environmental temperature humidity shock and vibration tolerances noted in the Specifications section of this manual Those specifications are listed again below for your convenience Environmental Specifications Operating Temperature 50 F 113 F 10 C 45 C Storage Temperature 4 F 122 F 20 C 50 C Relative Humidity non condensing 10 80 Shock Resistance Operating 30g half sine for 11ms Vibration Operating 15 to 57Hz 0 006 peak to peak 57 to 640Hz Resistance sine 1 0g peak to peak Altitude Max 1 89mi 3 05km 5 1 Cleaning Prior to cleaning the CYRAQ unit disconnect power to the device 5 1 1 Touchscreen Clean the touchscreen with household glass cleaner or just plain water and soft cloth gt We do not recommend using paper products to clean the touchscreen gt Always dampen the towel first and then clean the touchscreen to reduce abrasion from the cleaning applicator gt Glass cleaner sprayed directly onto the CYRAQ s screen could possibly be over sprayed leak into the back of a unit if not mounted correctly and cause damage 5 1 2 LCD Clean the LCD screen with household glass cleaner or just plain water and soft cloth gt Do not spray cleaner or water directly on any part of the unit front or back gt We do not recommend using paper products to clean your display screen gt Always dampen a soft cloth first and
37. lors Maximum Color Depth in Bits Contrast Ratio Auto Sizing to Fill Screen Viewing Angle j Horizontal Vertical Vertical Scanning Horizontal Frequency Vertical digital signals Horizontal digital signals Dot Pitch Backlight Type LCD flat panel Standard analog VGA 15 pin DVI Digital Visual Interface 21 3 20 and larger 250 nits High Bright High bright 250 to 340 nits 1600 x 1200 pixels e Optimum Resolution 1600x1200 60Hz Max Resolution 1600x1200 60Hz Supports 1280x1024 1024x768 800x600 and 640x480 16 million colors 24 bit color 500 1 Yes 170 170 56Hz 75Hz 30KHz 93KHz 56Hz 75Hz 30KHz 81KHz 0 27mm CCFT CyberResearch Inc 25 Business Park Drive Branford CT USA 5 P 203 483 8815 F 203 483 9024 www cyberresearch com CYRAQ 21 CyberResearch Displays Chassis Mounting Configuration Protection Rating Display Filter Protection Front Panel Material Chassis Material Height Rack Units Front Panel Color Custom Color Options Chassis Special Features Mounting VESA Mounting Hole Pattern Stand Features Rack mount EIA 19 Panel mount Desktop benchtop Wall mount Swivel arm mount NEMA 4 sealed front panel IP65 dustproof most low pressure jets of water Water Resistant NEMA 4 12 IP65 Stainless steel Stainless steel 9U 15 75 Stainless steel Custom color available min qty 50 Features an ultr
38. menu that appears CyberResearch Branford onnecticut USA CyberResearch Inc 29 25 Business Park Drive P 203 483 8815 F 203 483 9024 Branford CT USA www cyberresearch com CYRAQ 21 CyberResearch Displays 5 Choose the setup language for the installation Choose Setup Language Select the language for the installation from the es below Chinese Simplified French Standard G Welcome to the InstallShield Wizard for MagicRotation The InstallShield Wizard will install MagicRotation on your computer To continue click Next InstallShield 30 Copyright 2005 CyberResearch Inc CyberResearch Displays CYRAQ 21 7 When the license agreement appears click one of the radio buttons to accept or reject the terms of the agreement and then click Next Install Shield END USER LICENSE AGREEMENT FOR SAMSUNG ELECTRONICS MagicRotation A SOFTWARE PRODUCT IMPORTANT READ CAREFULLY This Samsung Electronics End User License Agreement EULA is a legal agreement between you either an individual or a single entity and Samsung Electronics Co Ltd SAMSUNG ELECTRONICS with respect to the SAMSUNG ELECTRONICS product identified above The SAMSUNG ELECTRONICS software product may include copying or using the SOFTWARE PRODUCT you agree to be bound by the terms of this EULA If you do not agree to the terms of this EULA you may not install or use the SOFTWARE PRODUCT The SOFTWAR
39. mmended Video Cards sieves a a tal 9 Ze daze ccs sees cn let ata de e RS A sata dai 10 2 1 Unpacking the CYRAQ TE aaa aa data la 10 2 1 1 Your Package Comida 10 2152 Optional Accessories td 11 2 1 3 Ordering TAN ts naarn 3 a a oa a a ti 11 2 2 Rack Mounting CRXF CREAR id cido 12 2 2 1 Rack Mount Gasket Installation 13 222 Landscape Orientation eseu rs an SS 14 223 Portrait OCERTALIOD ata da a dd d da 15 2 3 Panel Mounting CRXF CRXZR zl a 16 2 3 1 Panels Mount Gasket Installation 16 2 3 2 Panel Mounting the Monitor 17 2A Flush Panel Mounting CPXF CPXR21A cesse ba aaa ad at a 18 2 4 1 Panel Mounting the Monitor isis 18 2 5 VESA Mounting CVBE CVBR 21 20 2 6 60 22 2 7 Display Driver Install ii sanitaires 24 2 8 Screen Rotation SoftWare vrs lar de 28 2 8 1 MagicRotation 28 2 8 2 MagicRotationTM Operations a creadas diana zale 34 2 8 3 Pivot Pro Instala O Didi si e utila 35 2 8 4 Pivot Pro Operation 8 38 Or Umi CYRAOQ TS RE ERE oa RA antics ARES RE Nea op RA no 39 3 1 User ControlSiscnissi eg a E e ie al 39 3 2 Adjustine the Display ia a ct rca 40 3 2 1 AGO ATIUS ea coaie al n E i a tr d h 40 3 2 2 BAR to e don te to ad rd e nas nn 40 3 2 3 41 3 2 4 Adjusting Contrast sta aiii 42 3 2 5 Adjusting the Image Levels ui 42 3 2 6 Color Controlado al 44 3 2 7 0 en acacia lanul d tt ll 45 3 2 8 Cus
40. n Off Button on the front of the display the status light will illuminate Start the computer 5 Ifthe computer is running restart The display should now function normally gt NOTE See section 4 Touchscreen for connection and driver instruction FR NOTE If the CYRAQ s screen remains blank or displays the error message Out of Range or No Input Signal there may be a connection or signal problem One or a combination of the possibilities listed below may be the cause gt Windows resolution is set either too high or two low for the display check the resolution by reinstalling the old monitor gt The refresh rate may be set too high The refresh rate of an LCD monitor doesn t need to be set as high as a CRTs refresh rate set the refresh rate 60Hz 22 OCopyright 2005 CyberResearch Inc CyberResearch Displays CYRAQU 21 gt The power source isn t 115VAC gt The video cable isn t tightly connected at one or both ends reconnect and tighten the cable adapter screws gt The analog and DVI cables are both connected to the display and the same computer gt The display is reading the wrong video input push the Exit Source button to toggle between the VGA and DVI inputs gt The unit is malfunctioning CyberResearch Inc 23 25 Business Park Drive P 203 483 8815 F 203 483 9024 Branford CT USA www cyberresearch com CYRAQ 21 CyberResearch Displays 2 7 Display Driv
41. n mounting plate rack mount holes with server rack mounting holes see Figure 3 for correct mounting orientation Ensure gasket faces outward 2 Install the eight 10 32 1 2 button head bolts into rack mounting holes to secure mounting plate to the server rack R gt NOTE Steps 3 amp 4 require two people 3 Align studs with the monitor mounting holes in mounting plate and install the CyRAQ until the gasket is flush with rear of enclosure Important Do not exceed 30 in lbs when tightening mounting nuts 4 From inside rack a second person must install and tighten the fourteen 10 32 mounting nuts pack Mounting Plate to Rack Display to Mounting Plate Figure 3 Rack Mount Landscape Installation 14 OCopyright 2005 CyberResearch Inc CyberResearch Displays CYRAQ 21 2 2 3 Portrait Orientation Note Follow Rack Mount Gasket Installation procedure if necessary prior to beginning the steps below 1 Align mounting plate rack mount holes with server rack mounting holes see Figure 4 for correct mounting orientation Ensure gasket faces outward 2 Install the eight 10 32 1 2 button head bolts into rack mounting holes to secure mounting plate to the server rack Note Steps 3 amp 4 require two people 3 Align studs with the monitor mounting holes in mounting plate and install the CyRAQ until the gasket is flush with rear of enclosure Important Do not exceed 30 in lbs when tightening mo
42. nfigured MagicRotation InstallShield Wizard Setup Status MagicRotation is configuring your new software installation L 2 InstallShield 32 Copyright 2005 CyberResearch Inc CyberResearch Displays CYRAQ 21 11 When the Installation Wizard completes the installation the option is given to restart recommended your computer Click one of the radio buttons then click Finish MagicRotation InstallShield Wizard InstallShield Wizard Complete mpleted installing MagicRotation 9 Yes want to restart my computer now No will restart my computer later Click Finish to complete the setup InstallShield CyberResearch Inc 33 25 Business Park Drive P 203 483 8815 F 203 483 9024 Branford CT USA www cyberresearch com CYRAQ 21 CyberResearch Displays 2 8 2 MagicRotation Operation 1 After completing the installation restarting your computer is recommended an icon appears in your taskbar tray like the one below 12 10 PM Figure 18 Screen Rotation Software Icon 2 To access the screen rotation program menu right click on the icon shown in Figure 18 Rotate Rotate to 0 Rotate to 90 Rotate to 180 Rotate to 270 HotKey Help About Exit Figure 19 Screen Rotation Program Menu From the menu you can choose to rotate your desktop several different ways assign hotkeys or view online help 34 OCopyright 2005 CyberRe
43. ng the same point on the touchscreen for a specific amount of time predetermined on the Click Settings tab of the TSHARC Control Panel You can enable this functionality and define the amount of time necessary on the Click Settings tab as seen in Figure 38 Hampshire TSHARC Control Panel Rev 6 18f Screen Selection Calibration Click Settings Touch Settings Capacitive Right Click Emulation Touch to Test A right click will be sent when you touch the same point on the touch screen for a predefined period of time Enable right click and set time below Available only in Normal touch mode M Enable right click emulation N Select Apply to test Event Area Settings The event area is the touch area where right click touches occur This area may be sized to your application needs op lt lt Figure 38 Click Settings Tab 1 Click the Enable right click emulation checkbox to activate this feature 2 The slider below the checkbox is used to determine the amount of time necessary when holding down a touchpoint to generate the right click event Event Area Settings Since it may be difficult to touch and hold an exact point on any touchscreen for a length of time an event area is used to establish the size of the area in which a hold is acceptable 3 The even area should be set to at least the same size as your finger tip 4 Click or touch Apply to apply your selection OK to apply and ex
44. ntee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television receptions which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures e Reorient or relocate the receiving antenna e Increase the separation between the equipment and receiver e Connect the equipment into an outlet on a circuit different from that to which the receiver is connected e Consult the dealer or an experienced radio TV technician for help European Notice Products with the CE marking comply with the EMC Directive 89 336 EEC 92 3 1 EEC 93 68 EEC and the Low Voltage Directive 73 23 EEC issued by the Commission of the European Community Compliance with these directives implies conformity to the following European Norms e EN55022 1998 A1 2000 Radio Frequency Interference e EN55024 1998 Electromagnetic Immunity of Information Technology Equipment e EN61000 3 2 1995 A1 A2 1998 Power Line Harmonics e EN61000 3 3 1995 Voltage Fluctuations 4 Copyright 2005 CyberResearch Inc CyberResearch Displays CYRAQ 21 1 4 Specifications Display Display Type Video Input Types Screen Size viewable area diagonal Display Filter Screen Size Display Brightness Display Filter Brightness Resolution max Display Special Features Maximum Number of Co
45. nually choose the input via the Source button on the display To set the action for the Source button l AR 0 Da Press the Menu button to access the OSD Using the or button choose the Source select tab see Figure 32 Press Menu to select Use the and button to toggle between Auto and Manual When done press Exit Source Select Auto Manual 74 8kHz 60Hz PP 1600 x 1200 Analog Figure 32 Source Select Menu 46 Copyright 2005 CyberResearch Inc CyberResearch Displays CYRAQ 21 4 Touchscreen Touchscreens are the ultimate human machine interface In a touchscreen system touching what you see onscreen makes the computer respond The touchscreen system is logical intuitive and simple Using touchscreens workers can precisely control complicated processes without being tethered to a keyboard and mouse People who have never used a computer before can immediately interact successfully with a touchscreen based computer system allowing airline customers to access flight information CNC machinists to quickly change programs and wait staff can instantly send your order to the kitchen all with the touch of their finger 4 1 Installation The Touchscreen and internal controller board inside your CYRAQ display have already been installed for you by the engineers at CyberResearch Inc You should never need to open the case of this unit to install change any of the internal connections or for an
46. o portrait Rack Mount applications OR CPBF CPBR CPSF amp CPSR 21A come with one Compression Mounting Plate lieu of CRMS UNL or CRMS POR Eight Button Head Mounting 10 32 1 2 Bolts Fourteen 10 32 Mounting Nuts 10 Copyright 2005 CyberResearch Inc CyberResearch Displays CYRAQ 21 2 1 2 Optional Accessories 1 Longer VGA and DVI cables call for available lengths 2 Touchscreens are available for all models 3 SWC 100 VESA mounting plate for VESA mount models gt NOTE If any of these items are missing or damaged contact CyberResearch Inc immediately 2 1 3 Ordering Information HCRSR 24C eee Universal Mount Rear Controls CRBR 24605 Universal Mount Rear Controls CRSF 24C oo Universal Mount Front Controls CRBF 24C ceeeeeeeeeeee Universal Mount Front Controls CRSF 2190 Universal Mount Front Controls CRBF 21A Universal Mount Front Controls CRSR 21A ooo Universal Mount Rear Controls CRBR 212 eee Universal Mount Rear Controls CVSF 21A oe VESA Mount Only Front Controls CVBF 21A eee VESA Mount Only Front Controls HOVSR 21A eee VESA Mount Only Rear Controls CVBR 21 VESA Mount Only Front Controls HCPSF 214 Panel Mount Front Controls CPBF 21 9 Panel Mount Front Controls CPSR 21A eee Flush Panel Mount Rear Controls CPBR 21A Flush Panel Mount Rear Controls
47. omponent to this monitor s NEMA 4X rating for watertightness it must be installed correctly to meet this standard It is also important to note that the rack mount installation procedure differs from the panel mount procedure Please read the instructions below carefully before installing the gasket i Se 1 On a flat surface orientate the mounting plate amp an A as depicted in Figure 2 OS 0 2 Arrange the gasket to match mounting plate 3 Remove adhesive backing from Section A of the gasket Center Hole f NOTE It s important to focus on aligning the holes of gasket and mounting plate rather than their respective edges 4 Align center hole in gasket with center hole on mounting plate take care not to let other portions of the gasket in Section A touch mounting plate until aligned properly 5 Carefully align and place the rest of Section A holes working out from center Figure 2 Gasket Installation 6 When done firmly press down and smooth gasket in Section A 7 Repeat process for each of the other three sides CyberResearch Inc 13 25 Business Park Drive P 203 483 8815 F 203 483 9024 Branford CT USA www cyberresearch com CYRAQTM 21 CyberResearch Displays 2 2 2 Landscape Orientation F amp NOTE Portrait mounting orientation requires 11U 19 2 free rack space R gt NOTE Follow Section 2 2 1 Rack Mount Gasket Installation procedure prior to beginning the steps below 1 Alig
48. onsistently operated at high temperatures keep rack temperature as low possible 4 Is there a possibility that the ambient humidity around the display will exceed its rated specification Relative Humidity non condensing 10 80 Server Rack Cutaway Mounting Plate Bolt Supplied CYRAQ Mounting Nuts Supplied CYRAQ Display FR NOTE CRMS Universal Mounting Plates Affixed Directly to Server Rack s Mounting Holes CRMS UNL Universal Mounting Plate Figure 1 Installation Assembly 12 Copyright 2005 CyberResearch Inc CyberResearch Displays CYRAQ 21 2 2 1 Rack Mount Gasket Installation Installing the CYRAQ in the landscape orientation requires 9U 15 5 free rack space Prior to installing the CYRAQ into a rack the included gasket must be affixed to the mounting plate IMPORTANT Unless requested at the time of purchase the display is shipped with gasket applied Skip to section 2 2 2 However in certain instances the mounting gasket may be shipped loose to allow for increased installation flexibility in the case of custom applications This permits customers to then choose which mounting application best suits their environment panel or rack mount Affixing the gasket to the back of the CYRAQ s enclosure is recommended for panel mounting applications while adhering directly to the mounting plate is recommended for rack mount applications The mounting gasket is a critical c
49. pective companies e NOTICE CyberResearch Inc does not authorize any CyberResearch product for use in life support systems medical equipment and or medical devices without the written approval of the President of CyberResearch Inc Life support devices and systems are devices or systems which are intended for surgical implantation into the body or to support or sustain life and whose failure to perform can be reasonably expected to result in injury Other medical equipment includes devices used for monitoring data acquisition modification or notification purposes in relation to life support life sustaining or vital statistic recording CyberResearch products are not designed with the components required are not subject to the testing required and are not submitted to the certification required to ensure a level of reliability appropriate for the treatment and diagnosis of humans CyberResearch Inc iii 25 Business Park Drive P 203 483 8815 F 203 483 9024 Branford CT USA www cyberresearch com CYRAQ 21 CyberResearch Displays Intentionally Blank iv OCopyright 2005 CyberResearch Inc CyberResearch Displays CYRAQ 21 Table of Contents l o A ia nt 1 1 1 Why the CYRAQ 20 ni ans 2 1 2 CyberResearch AR Bonding Technology 3 1 3 Product Safety and Regulatory Information 4 1 4 o O nd die 5 1 5 PE 0 9 1 5 1 OVERVIEW ni at oaia a ja d aaa he ER en tut a a Let 9 1 5 2 SA A 9 1 5 3 Reco
50. search Inc CyberResearch Displays CYRAQ 21 2 8 3 Pivot Pro Installation Pivot Pro screen rotation software is not included in all CYRAQ packages see 2 8 1 MagicRotation Installation if your packaging doesn t contain a Pivot Pro CD If your package does contain a Pivot Pro software CD proceed with the following instruction R gt NOTE Close all unnecessary applications before continuing at the end of this procedure you will be prompted to restart your computer 1 Insert the Pivot Pro CD into your CD drive 2 When the splash screen appears choose Install Pivot Software A Pivot Pre PET 2 ric r7 1 gt JISUIAV UI fito L f Jenrl rrr VUULLI Why Pivot 4 Pivot Screen Orientations e Documentation and Qu 4 o ic Co Learn ther Display Products Welcome to the Pivot Software Setup Wizard The Setup Wizard will install Pivot Software on your computer Click Next to continue or Cancel to exit the Setup Wizard CyberResearch Inc 35 25 Business Park Drive P 203 483 8815 F 203 483 9024 Branford CT USA www cyberresearch com CYRAQ 21 CyberResearch Displays 4 To continue click the I accept radio button then click Next Pivot Software License Agreement End User License Agreement Please read the following license End User Software License Agreement When you open the Pivot Software package you indicate your accep
51. stallation ita 13 Figure 3 Rack Mount Landscape Installation 14 Figure 4 Rack Mount Portrait 15 Figure 5 Panel Mount Gasket Installation oonooonnccnnnncnnoninococonoconcconnnonnnaconocono conc cconncnns 16 Figure 6 Panel Mount Landscape Installation 17 Figure 7 Flush Panel Mount Landscape Installation 19 Figure 8 100 x 100mm VESA Mounting Holes nene nenea n 20 Figure VESA Arm A ts A Care 20 Affix Clamp to Bene htop in niee enr ns 20 SWC 100 Adapter Mounting Plate ass 20 8 21 Mounting Arm to Display ssl ann de ar dn ta dde 21 Mounting Arm Base to Clamp ss mens naine 21 Adjust Weight Capacity nn tn a de Re det a de 21 CY RAO Connection Lavoine 22 7 24 Screen Rotation Software Icon 34 Screen Rotation Program Menu dans 0 a d aia 34 Pivot PEDALE Of sit oaie du A te ed den 38 Pivot Pro Option MENU za stea dea oala nt Ne Te 38 Auto Adjustment Progress Baf sasa sora ca tao aaa ada ca a ata rada 40 Brightness oss is Se ea de aida 40 View of mitia OSD oi na A ta as Daia asta el 41 Contrast Ta ea ata eds va ful Re 42 MA 1 0 42 Fine AUS IMA td a aa nt nine aia a nantes 43 Color Cotto Ea 44 Gamma USA aos 44 ATI OAS Mena iia 45 OSD MU dan 46 SOUTC Select MM nee 46 Touchscreen Cable La ns nn as eh awe 47 Splash 0 E Ca a lt a da 48 Install Products ai a nem add a ai 49 Calibr tion A dle aaa but 54 Calibration LA a NRA vada aa i ele 35 Chick Settings Tab 58 Touch Settings Lab caia 5
52. sure is recommended for panel mounting applications while adhering directly to the mounting plate is recommended for rack mount applications The mounting gasket is a critical component to this monitor s NEMA 4X rating for watertightness it must be installed correctly to meet this standard It is also important to note that the rack mount installation procedure differs from the panel mount procedure Please read the instructions below carefully before installing the gasket 1 Place the monitor face down on a flat surface with bottom of the monitor closest to you take care not to damage or scratch the screen 2 Arrange the gasket to match monitor orientation align Section D with bottom of monitor s enclosure 3 Remove adhesive backing of Section A on gasket R gt NOTE It s important to focus on aligning the holes of gasket and studs on the rear of the enclosure rather than their respective edges 4 Align center hole in Section A of gasket with center stud on rear of monitor take care not to let other portions of the gasket touch mounting plate until aligned properly 5 Carefully align and place the rest of Section A working out from center 6 When done firmly press down and smooth gasket in Section A 7 Repeat process for each of the other three sides Figure 5 Panel Mount Gasket Installation 16 Copyright 2005 CyberResearch Inc CyberResearch Displays CYRAQ 21 2 3 2 Panel Mounting the Monitor 1
53. t 62 Figure 22 Auto Adjustment Progress Bar 3 2 2 Brightness Adjusting the Brightness level can be accomplished without actually prompting the full OSD using the Menu button To adjust the display s brightness 1 Press either the Plus or Minus button on the front of the display gt The Brightness indicator bar appears see Figure 23 2 Press either the Plus or Minus button to adjust the setting 3 When done press Exit Brightness si Figure 23 Brightness 40 Copyright 2005 CyberResearch Inc CyberResearch Displays CYRAQ 21 3 2 3 Accessing the OSD The OSD is the GUI used to adjust the display settings The OSD contains a menu with Brightness Contrast Color Control Language Menu Position and Source Select options 1 To access the OSD menu press the Menu button on the front of the display amp OSD Operation Tip When the Indicator Bar and its corresponding number are blue they can be adjusted using the and buttons on the front of the display when the Indicator Bar appears black press the Menu button to activate the adjustment feature then adjust level using the and buttons on the front of the display 2 The OSD will appear see Figure 24 3 Press Menu button to activate the Brightness menu Indicator Bar will turn blue 4 Brightness can now be adjusted using the and buttons 5 When done press Exit do ujo blo Brightness Fig
54. tance of this license agreement Pivot Software is the property of Portrait Displays Inc and is protected by United States and International copyright laws Portrait Displays Inc grants you a non exclusive license to use one copy of Pivot Software on a single computer display device You may not duplicate the software except to make a single backup copy or to install on a hard disk or on multiple computers if they are all attached to and using the same display You may transfer the Pivot Software to another narenn anl iF umi rakain na raniae of the enFhuara and the nam mamar fe N accept the terms in the License Agreement CM do not accept the terms in the License Agreement lt Back Cancel 5 Enter the appropriate information then click Next Pivot Software Setup Customer Information Please enter your customer information User Name User Name Organization ACME Inc Cancel 6 To install the Pivot Pro software click Next Pivot Software Setup Installing Pivot Software Installing Pivot Software This may take a moment Status About to copy files 36 Copyright 2005 CyberResearch Inc CyberResearch Displays CYRAQ 21 7 When done click Next Pivot Software Setup Installing Pivot Software Installing Pivot Software This may take a moment 8 Then click Finish Pivot Software Setup Completing the Pivot Software Setup Wizard Click the Finish b
55. tine 1 Click touch the calibration target seen in Figure 36 to begin calibration routine Hampshire TSHARC Control Panel Rev 6 18f Touch or click the calibration target to calibrate the touch screen Administrator Access is Required Configure Test Configure the calibration type Test touch screen calibration and offset Figure 36 Calibration Target 2 Follow the on screen prompts to complete calibration process Once you have selected the large calibration target from the control panel the calibration program will begin 3 As each target is displayed on the screen TOUCH and hold the center of each target as directed by the text located adjacent to each target 4 Touch the center of each target as accurately as possible Hampshire calibration targets have been specially developed to assist you in calibrating your touchscreen as accurately as possible 5 As each target is displayed touch and hold the center of each calibration target until it shrinks and the Hold text changes to Release The calibration screen will automatically time out and return you to the control panel if the first point is not touched within 10 seconds This time out feature has been added to the calibration program to insure that you can exit the calibration screen in the event that you have a damaged our disconnected touchscreen This time out feature may also be configured for other time out values 54 OCopyright
56. to determine if you touchscreen is working properly 1 Open the Hampshire TSHARC Control Panel Star All Programs Hampshire TSHARC Control Panel Hampshire TSHARC Control Panel Rev 6 18f Screen Selection Calibration Click Settings Touch Settings Capacitive Selection Information Instructions HAMPSHIRE 1 Select the monitor to calibrate use the number keys or the mouse 2 Switch to Calibration Tab 3 Click calibration target This is Monitor Information COMPANY Hampshire TSHARC Control Panel Rev 6 18f Screen Selection Calibration Click Settings Touch Settings Capacitive Touch or click the calibration target to calibrate the touch screen Administrator Access Requised a Configure Test Configure the calibration type Test touch screen calibration and offset 7 56 Copyright 2005 CyberResearch Inc CyberResearch Displays CYRAQ 21 3 Tap some points on the screen or write a word to ensure the program renders the contact points correctly JEDI Quit 4 When done click touch Quit CyberResearch Inc 57 25 Business Park Drive P 203 483 8815 F 203 483 9024 Branford CT USA www cyberresearch com CYRAQTM 21 CyberResearch Displays 4 2 6 Right Click Emulation The TSHARC Control Panel permits users to enable Right Click Emulation which simulates functionality where applicable of a right mouse click It works by touchi
57. tomize OSD MENIU sa sea a oa dal la aa il ial a da nes 45 3 2 9 SOULCE unir las 46 47 CyberResearch Inc v 25 Business Park Drive P 203 483 8815 F 203 483 9024 Branford CT USA www cyberresearch com CYRAQ 21 CyberResearch Displays 4 1 A 0 des td tg 47 4 1 1 Serial Cable Connection tai dl dul aA 47 4 1 2 USB Cable Conte coma do td Nes ic tas 48 4 1 3 Touchscreen Driver Installation 48 4 2 Cabra NS 52 4 2 1 Calibration 000 52 4 2 2 Configure Calibration SONES citando ia aaa a 52 4 2 3 Calibration Routine it Sin ren sn it ll 54 4 2 4 Calibration PES tude aes dd ae ala oa au 55 4 2 5 Drawing Test asias 56 4 2 6 Right Chick Emulation dada 58 4 2 7 A A sans 59 A a Carel LA Eee cet Re A ds acta lca as 60 5 1 6 AA AAA AAA A a AN dd ad 60 5 1 1 AR 00 5 1 2 00 52133 Fam TRS II ns 61 6 Mechanical ET MINS casos ata ne toda 62 vi Copyright 2005 CyberResearch Inc CyberResearch Displays Figure 10 Figure 11 Figure 12 Figure 13 Figure 14 Figure 15 Figure 16 Figure 17 Figure 18 Figure 19 Figure 20 Figure 21 Figure 22 Figure 23 Figure 24 Figure 25 Figure 26 Figure 27 Figure 28 Figure 29 Figure 30 Figure 31 Figure 32 Figure 33 Figure 34 Figure 35 Figure 36 Figure 37 Figure 38 Figure 39 Figure 40 Figure 41 Figure 42 CYRAQ 21 Table of Figures Figure 1 Installation Assembly a A 12 Figure 2 Gasket In
58. ty setting prior to installation 9 Use the T hex key provided to adjust the weight capacity Figure 15 a Carefully support the main body of arm while gently pushing downward b Turn hex key counterclockwise toward to decrease capacity c Clockwise toward to increase capacity Figure 15 Adjust Weight Capacity CyberResearch Inc 21 25 Business Park Drive P 203 483 8815 F 203 483 9024 Branford CT USA www cyberresearch com CYRAQ 21 CyberResearch Displays 2 6 Connecting the Display IMPORTANT Before connecting the power cable to the display connect all the other cables first Figure 16 CYRAQ Connection Layout er e dl E IM JU 1111 1 11 1 1 1 1111 1111 d 8 OD JUL AL NL JR s ELI 1 Power DVI Video Analog USB Port Switch Port Video Port Serial Port gt NOTE Turn off the computer before connecting the display 1 After connecting all other cables connect the power cable to the power jack on the back of the display refer to Figure 16 Flip the Power Switch on the rear of the display Figure 16 to the On position 3 Press the O
59. ual analog and digital source input Its Dual input VGA and DVI allow users to connect two different input sources simultaneously The CYRAQ 21 offers a 500 1 contrast ratio 1600 x 1200 resolution pixel pitch of 0 270mm H V Xtrawide 170 170 viewing angle Analog Digital video inputs a scanning frequency of 30 93 kHz horizontal and 56 85 Hz vertical and advanced image scaling gt 21 3 Viewable Screen Size gt 1600 x 1200 67 Hz gt Breakthrough Universal Mounting Plate Allows the 21 3 CYRAQ to Mount in a 19 Rack gt 0 27 MM Dot Pitch gt Connects Via VGA 15 Pin and Digital DVI gt Source Button Allows User to Toggle Between Inputs gt NEMA 4X Rating gt Rack Panel or Swivel Arm Mounted 1 5 2 System Requirements To achieve optimum response time the CYRAQ requires a computer with CPU speeds of 486 or higher The CYRAQ is compatible with Windows and Macintosh operating systems To operate the display at its highest resolution a video card that supports 1600 x 1200 pixels is required See 1 4 3 for CyberResearch video cards that meet this requirement 1 5 3 Recommended Video Cards The CyberResearch video cards listed below support the CYRAQ 21 maximum video resolution of 1600 x 1200 most of the cards listed exceed this specification Given the nature of the video card market one or more of the cards listed below may be replaced by a card with superior technology and capabilities at a more reasonable price
60. unting nuts 4 From inside rack a second person must install and tighten the fourteen 10 32 mounting nuts Mounting Plate to Rack Display to Mounting Plate Figure 4 Rack Mount Portrait Installation CyberResearch Inc 15 25 Business Park Drive P 203 483 8815 F 203 483 9024 Branford CT USA www cyberresearch com CYRAQTM 21 CyberResearch Displays 2 3 Panel Mounting CRxF CRxR 21 Prior to performing subsequent steps ensure the panel mounting location including panel thickness is suitable for the CYRAQ 21 and meets Environmental requirements in Specifications section NOTE Panel thickness should not exceed 55 14 1mm if the unit has the standard 3 2mm 1 8 Poron gasket installed Suggested panel thickness is calculated based on standard CYRAQ 21 parts and dimensions custom units may not meet these specifications Prior to panel mounting a CYRAQ the included gasket must be affixed to the rear of the enclosure 2 3 1 Panel Mount Gasket Installation IMPORTANT Unless requested at the time of purchase the display is shipped with gasket applied Skip to section 2 3 2 However in certain instances the mounting gasket may be shipped loose to allow for increased installation flexibility in the case of custom applications This permits customers to then choose which mounting application best suits their environment panel or rack mount Affixing the gasket to the back of the CYRAQ s enclo
61. ure 24 View of Initial OSD CyberResearch Inc 41 25 Business Park Drive P 203 483 8815 F 203 483 9024 Branford CT USA www cyberresearch com CYRAQTM 21 CyberResearch Displays 3 2 4 Adjusting Contrast Level To adjust the Contrast level 1 Press the Menu button to access the OSD Using the or button choose the Contrast tab see Figure 25 Press the menu button to activate the Contrast menu Contrast can now be adjusted using the and buttons When done press Exit OB Contrast e Figure 25 Contrast Tab 3 2 5 Adjusting the Image Levels To adjust the Image Levels 1 2 3 4 Press the Menu button to access the OSD Using the or button choose Image see Figure 26 Press the menu button to activate the Image menu Choose an item on the Image submenu using the or button and then press Menu for example the Fine adjustment Coarse Fine H Position V Position Image Effect Figure 26 Image Tab 42 OCopyright 2005 CyberResearch Inc CyberResearch Displays CYRAQ 21 5 When the submenu choice appears use the or button to adjust 6 When done press Exit oO PR Fine EE 7 Figure 27 Fine Adjustment CyberResearch Inc 43 25 Business Park Drive P 203 483 8815 F 203 483 9024 Branford CT USA www cyberresearch com CYRAQ 21 CyberResearch Displays
62. utton to exit the Setup Wizard Yes No CyberResearch Inc 37 25 Business Park Drive P 203 483 8815 F 203 483 9024 Branford CT USA www cyberresearch com CYRAQ 21 CyberResearch Displays 2 8 4 Pivot Pro Operation 1 After completing the installation restarting your computer is necessary an icon appears in your taskbar tray like the one below 6 12 43 PM Figure 20 Pivot Pro Icon 2 To access the Pivot Pro program menu click on the icon shown in Figure 20 From the menu you can choose to rotate your desktop several different ways view online help or choose from other options Floating Button gt Help About Check for Upgrade Technical Support a Rotate E Rotate to o BJ Rotate to 90 E Rotate to 180 BJ Rotate to 270 4 To access Pivot Pro options right click on your desktop and choose Plug and Play Monitor and NVIDIA GeForce FX 5700 da a Properties General Adapter Monitor Troubleshoot b S ettings Color Management Pivot Software c Advanced Options HotKey A About d Pivot Software Show Pivot icon in the system task tray Show splash screen on startup Allow rotate through available orientations Allow rotate to 0 Allow rotate to 90 Allow rotate to 180 Allow rotate to 270 Enable Pivot options on desktop Correct the movement of the mouse in rotated modes O Correct the movement of the pen in rotated modes Figure 21
63. y other reason If you think there is an internal connection problem contact CyberResearch Inc immediately 4 1 1 Serial Cable Connection 1 Shutdown your computer 2 Plug the DB9 male end of the supplied serial cable into the DB9 female connector on the back of the CYRAQ enclosure 3 Plug the DB9 female end of this cable into the computer s DB9 serial port If you have a 25 pin serial port use the optional DB9 male to DB25 female adapter PC Bus Controller Touchscreen PA Cable Video DB9 J Cable F Figure 33 Touchscreen Cable Layout CyberResearch Inc 47 25 Business Park Drive P 203 483 8815 F 203 483 9024 Branford CT USA www cyberresearch com CYRAQ 21 CyberResearch Displays 4 1 2 USB Cable Connection 1 Shutdown your computer 2 Plug the USB cable into the CYRAQ s USB connector on the back of the enclosure 3 Plug the other end of the USB cable into a free USB port on the back of the computer 4 1 3 Touchscreen Driver Installation 1 Reboot your computer 2 After Windows loads put the CyberResearch Software and Utilities CD into the CD drive CyRAQ Series V2 3 i S INSTALL DRIVERS M gt gt 1 Software Drivers amp Utilities VIEW MANUALS CONTENTS CONTACT US D C herResearch Figure 34 Splash Screen 3 When the splash screen appears Figure 34 click on Install Drivers 48 Copyri

Download Pdf Manuals

image

Related Search

NOTE notepad++ notes notebook lm notepad++ download notes app notepad app notepads noteflight notepad online notebook llm note gpt notes apple note taking apps notes online notebook lm google notebook app notepad program notepad free notepad++ for pc notebook paper notepad++ online notebook ml notebook klm