1. 227 Pilot Flame EBI 9 INSTALLER MUST LEAVE THESE INSTRUCTIONS WITH THE CONSUMER HAVE THEM COMPLETE AND RETURN THE WARRANTY CARD INTRODUCTION THIS IS A GAS FIRED GRAVITY VENTED WALL FURNACE THAT WILL OPERATE SAFELY AND PROVIDE AN EFFICIENT SOURCE OF HEAT WHEN INSTALLED OPERATED AND MAINTAINED AS RECOMMENDED IN THESE INSTALLATION AND OPERATING INSTRUCTIONS READ THESE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING SERVICING OR USING THE APPLIANCE IF YOU DO NOT UNDERSTAND ANY PART OF THESE INSTRUCTIONS CONSULT LOCAL AUTHORITIES OTHER QUALIFIED INSTALLERS SERVICE AGENCIES THE GAS SUPPLIER OR THE MANUFACTURER COUNTERFLOW WALL FURNACE SPECIFICATIONS Your counterflow wall furnace is packed in a single carton that also includes thermostat thermostat wire and insulated staples The thermostat wire and staples are packed in the burner compartment and are accessible by removing the burner access door While the burner access door is open check the rating plate to verify that the model number is correct and that the wall furnace is equipped for the type gas you intend to use MODELS WITH LOW BTU STANDING PILOT CF353C H 24 Volt Nat 35 000 14 5 16 Wx1044 Dx78 5 8 H 1 95 CF354C H 24 Volt L P 35 000 14 5 16 Wx1044 Dx78 5 8 H 1 95 CF503C H 24 Volt Nat 50 000 14 5 416 Wx10A4 Dx81 5 16 H 2 25 104 Lbs CF504C H 24 Volt L P 50 000 14 5 416 Wx10A4 Dx81 5 16 H 2 25 104 Lbs CF653C H 24 Vo
2. COUNTERFLOW WALL FURNACE INSTALLATION AND OPERATING INSTRUCTIONS P N 78111 REV 03 05 MODEL NUMBERS CF354C H CF504C H CF654C H NATURAL GAS CF357C H CF557C H IGNITION L 1 D L P GAS CF358C H CF558C H WARNING If the information in this manual is not followed exactly a fire or explosion may result causing property damage personal injury or loss of life Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS gt Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Follow the gas supplier s instructions with a blocked flue switch designed to protect against improper venting of combustion products gt gt Immediately call your gas supplier from a neighbor s phone This appliance is equipped gt If you cannot reach your gas supplier call the fire department INSTALLATION AND SERVICE MUST BE PERFORMED TC UNITIES NOT TO BY A QUALIFIED INSTALLER SERVICE AGENCY OR BE INSTALLED IN THE GAS SUPPLIER MOBILE HOMES WARNING Operation of this furnace when not connected to a properly installed and main tained venting system can result in Carbon Monoxide C O poisoning and possible death For your safety this furnace and the venting system should be inspected at least annually by a quali fied service person The coating sel
3. 653 654 PICTORIAL SCHEMATIC GAS VALVE AMPS 2 25 SELECTOR SWITCH LIMIT SWITCH TRANSFORMER THERMOSTAT CF503C H CF504C H CF653C H CF654C H LADDER SCHEMATIC SPILL SWITCH AUXILIARY LIMIT SWITCH 57 CF358C H CF357C H CF358C H THERMOSTAT PICTORIAL POWER CORD TRANSFORMER SPILL SWITCH P i Vos AUXILIARY LIMIT SWITCH MODEL NO SCHEMATIC SWITCH PILOT GAS VALVE CF357C H CF358C H FAN SWITCH LIMIT SWITCH TRANSFORMER THERMOSTAT AUXILIARY LIMIT SWITCH CF357C H CF358C H LADDER SCHEMATIC IGNITION MODULE GAS VALVE LLD WO AUXILIARY LIMIT SWITCH z 2 E z S MODEL NO CF557C H CF558C H CF557C H CF558C H PICTORIAL SCHEMATIC Fi i L on L H SELECTO FAN SWITCH SWITCH BLACK AMPS CF557C H CF558C H FAN SWITCH 25 2 55 SELECTOR SWITCH C CF557C H CF558C H LADDER SCHEMATIC SPILL AUXILIARY SWITCH Page 15 ROUGH INS FOR REAR OR SIDE DISCHARGE Install plastergrounds as shown in Figure 12 and Figure 13 NOTE When side discharge is being used furnace should be set exactly 4 from side wall OCO R Mi 12 Plaster Ground FIGURE 12 FIGURE 14 FIGURE 13 OPTIONAL ACCESSORY KITS REAR REGISTER KIT Flush Mount See Figure 14 Use optional kit No 406RR A Cut
4. If installed in an area of the home that is considered an unconfined space the natural infiltration of air around windows and doors will be adequate If the area is considered a confined space less than 50 cubic feet per 1 000 btu fresh air can be supplied by providing two permanent openings into adjoining rooms Each opening shall have a minimum free area of one square inch per 1 000 btu per hour of the total input rating of all gas appliances in the confined space but not less than 100 square inches One of the openings shall be within 12 inches of the ceiling and one within 12 inches of the floor See Figure A If the home is of unusually tight construction new and remodeled homes free air must be supplied through opening s to the outdoors This can be accomplished by providing 2 permanent openings one commencing within 12 inches of the ceiling and one within 12 inches of the floor These openings shall communicate directly with the outdoors or spaces that communicate freely with the outdoors such as a ventilated attic and crawl space through galvanized or equivalent corrosion resistant ducts Exception unobstructed stud and joist spaces are acceptable ducts provided that not more than one fire block is removed Special provisions must be taken to insure that these stud and joist spaces cannot be blocked with insulation or other objects Each of these openings using vertical ducts shall have a minimum free area of one square inch p
5. end of attic Outlet Air Inlet Air Duct ends 1 ft 300mm above floor ALL COMBUSTION AIR FROM OUTDOORS THROUGH SINGLE COMBUSTION AIR OPENING UL Listed Vent Cap UL Listed Gas Vent Opening Alternate Opening Location USING ADJACENT STUD SPACE FOR ALL LOCATION AND SPECIAL PRECAUTIONS COMBUSTION AIR FROM OUTSIDE HOLES CONNECTING TO The wall furnace should be located near the center of VENTILATED ATTIC _ the house for best heat distribution IIN If the area where the appliance is to be installed contains carpeting tile or combustible materials other than wood flooring the appliance shall be installed on a metal plate wood panel or other non combustible materials The use of ceramic or quarry tile is acceptable and will provide a surface that is easily cleaned This material is to extend the full width and depth of the appliance If side or rear warm air outlets are being installed see figure 14 18 See page 16 and 17 HOLES CONNECTING TO VENTILATED CRAWL SPACE BASED ON 4 000 BTU OF TOTALINPUT RATING OF ALLGAS APPLIANCES THE HEATER ONLY REQUIRES A MINIMUM FREE AREA OF SQUARE HOLE SQUARE BTU IN SIZE _IN 25 000 6 25 1 785 35 000 8 75 1 5 1 76 50 000 12 50 2 3 14 55 000 13 75 2 5 4 90 65 000 16 25 3 7 065 ROUGH IN INSTRUCTIONS In selecting a location for installation it is necessary to provide adequate
6. REVERSE SIDE OPTIONAL KITS CONTINUED SIDE DISCHARGE ON CASING Use optional kit No 306SR A Remove knockout from inner liner No flanges of boot to knockout on inner boot Mark screw holes and remove boot Drill holes with a 1 8 drill Attach inner boot with screws provided PAKON attach with screws provided Cut out and remove embossed area on casing side Place 1 1 2 boot from kit through opening matching Place grille into position drill holes into casing and FIGURE 16 90 Degree Outside Corner SECTION 3 FT SECTION 4 BOTTOM SECTION FIGURE 18 MODEL Length of bottom section NUMBER Ref 4 plastic raceway CF35 5 5 16 Inches 50 8 55 14 Inches CF65 14 Inches NOTE Above lengths terminate approximately 2 inches above floor STEP 1 STEP 2 STEP 3 STEP 4 STEP 5 STEP 6 STEP 7 STEP 8 STEP 9 SIDE DISCHARGE With Extension Boot 1 Use optional kit No 30SRB A 2 Cut opening in drywall as shown in Fig 17 3 Position plasterground as shown in Fig 17 optional 4 Cut out and remove embossed section on casing side 5 Remove knockout on inner liner 6 Put heater into position 7 Place inner boot into position mark and cut boot flush with wall Place outer boot into position mark and cut boot flush with wall 8 Place boot trim into position slide inner boot through wall from adjacent room and attach t
7. primary air adjustment on the burner and proper flame is assured since the correct manifold pressure and orificing has been done at the factory NOTE It is advised that the burner flames be checked at least twice during the heating season for any changes in burner flame characteristics The appliance area must be kept clear and free from combustible materials gasoline and other flammable vapors and liquids This heater comes from the factory with the proper burner orifice for elevations up to 2 000 feet Heaters installed above 2 000 feet must be derated 4 for every 1 000 feet For the proper orifice size find the Model Number and elevation on the orifice chart See CONTROLS Replace burner orifice FIGURE 11 OPERATION This unit uses a step open valve When heat is called for the gas valve opens at a reduced manifold outlet pressure to insure a safe quiet ignition After 10 20 seconds the valve automatically steps up to normal manifold outlet pressure to provide proper BTU input for the remainder of the heat cycle After the heat exchanger has warmed sufficiently the fan will automatically come on to efficiently transfer the heat into the room NOTE All but the 35 000 BTU unit which is one speed have an automatic two speed fan In a new installation or on fall start up in a very cold room some on off cycling of the fan may occur if the heat exchanger cools too much The burner however will continue to oper
8. 20 schematic drawings on current models are shown at www cozyheaters com HOW PROPERLY ORDER PARTS In addition to part description and part number please give model number serial number and type of gas used This information can be found on the rating plate that is attached to heater 24 VOLT SYSTEM WITH LOW B T U STANDING PILOT NATURAL CF353C H CF503C H CF653C H MODEL NUMBER L P CF354C H CF504C H CF654C H REF PART LIST PART LIST PART LIST PART DESCRIPTION NUMBER NUMBER PRICE NUMBER PRICE NUMBER PRICE Casing Side Right 30055 48 40 30325 49 00 30525 52 10 Casing Side Left la 30060 48 40 30330 49 00 30530 52 10 Center Back Assembly 1b 30114 37 10 30364 34 20 30544 36 80 Top Assembly lc 30025 13 30 30025 13 30 30025 13 30 Upper Back Assembly 1 30070 22 30 30070 22 30 30070 22 30 Lower Back Assembly le 30219 30 60 30219 30 60 30219 30 60 Bottom 1f 30246 9 80 30246 9 80 30246 9 80 Liner Assembly 30120 73 30 30370 74 00 30550 80 20 Header Assembly Complete 31399 38 60 31399 38 60 31399 38 60 Heat Exchanger Assembly 30133 210 60 30379 216 10 30563 216 10 Draft Diverter Assembly 30180 31 30 30400 42 30 30400 42 30 Fan Shroud Assembly 30200 21 60 30200 21 60 30200 21 60 Top Louver w Insulation 30087 17 60 30087 17 60 30087 17 60 Center Front Panel w Insulation 30089 24 90 30359 26 70 3053
9. 30047 81 90 30047 81 90 30047 81 90 Casing Mounting Brackets 32d 30260 1 20 30260 1 20 30260 1 20 Flue Pipe Gasket 33 78050 1 20 78050 1 20 78050 1 20 Draft Diverter Gasket 34 78051 1 20 78051 1 20 78051 1 20 Casing Top Gasket 34b 78049 1 20 78049 1 20 78049 1 20 Element Support Gasket 35 78052 4 40 78052 4 40 78052 4 40 Pilot NAT 0 140 512 36 72020 22 70 72020 22 70 72020 22 70 Pilot L P 0 140 502 36 72021 22 70 72021 22 70 72021 22 70 Cozy Handle 37 84003 2 30 84003 2 30 84003 2 30 Power Cord 38 78213 4 70 78213 4 70 78213 4 70 Snap in Outlet 39 78058 4 70 78058 4 70 78058 4 70 Thermostat Wire 41 74518 1 30 74518 1 30 74518 1 30 Thermocouple Q309A 2135 42 78095 11 40 78095 11 40 78095 11 40 Insulated Staples 4 74209 1 20 74209 1 20 74209 1 20 Door Catch 44 80005 1 20 80005 1 20 80005 1 20 Blocked Flue Switch 45 78108 9 30 78109 9 30 78109 9 30 Blocked Flue Switch Wire 46 78230 1 50 78230 1 50 78230 1 50 Terminal Board 52 78300 5 00 78300 5 00 78300 5 00 Pilot Tubing w Fittings 78452 5 40 78452 5 40 78452 5 40 Piezo Sparker 80016 5 70 80016 5 70 80016 5 70 Electrode Wire 72022 4 70 72022 4 70 72022 4 70 Burner Pan Assembly 53 30286 15 90 30286 15 90 30286 15 90 Valve Support Bracket Assembly 56 30290 4 70 30290 4 70 30290 4 70 Pilot Mounting Bracket 57 30299 2 40 30299 2 40 30299 2 40 Burner Mounting Plate 58 30296 2 80 30296 2 80 30296 2 80 Lighting Instr
10. Remove vent collar from top of header plate and place over flue extension and fasten to matching holes in casing top using screws from header plate Install B vent type base plate not supplied to top of vent collar Install ceiling plate spacer to back wall centered between studs Install B type vent to top of furnace terminating at least 12 above the floor and at least 2 above the roof line STEP 2 Fasten furnace to wall To secure top of furnace to wall loosen top screws on back casing and raise tabs up Tighten screws Screw through hole in top of tabs into anchors not provided Secure bottom using two holes provided in bottom of casing Optional Cover exposed vent with a vent enclosure kit Part Number 16VE A or 36VE A not included STEP 3 Make electrical connection of 115 V wiring into receptacle box not provided mounted on a wall Plug power cord from top of heater into receptacle Connect thermostat wire with thermostat wires extending from top of heater According to installation instructions with thermostat do not run wires in same stud space with vent system Thermostat should be a minimum of 4 from heater and 5 from floor STEP 4 Make gas connection using connector the same size as gas connection of furnace CHECK ALL CONNECTIONS FOR GAS LEAKS WITH LEAK DETECTOR SOLUTION DO NOT USE OPEN FLAME STEP 5 Replace and fasten all front panels 35 000 80 3 16 50 000 82 7 8 55 000 88 7 8 65 0
11. Vent Enclosure Side 16 Vent Enclosure Front 24 Vent Enclosure Side 24 Vent Enclosure Front 36 Vent Enclosure Side 36 Vent Enclosure Front Side Rear Register Side Register Large Outer Boot Large Inner Boot Small Outer Boot Small Inner Boot Boot Trim Plaster Ground Side Boot Cabinet Side Trim Angle Cabinet Top Trim Damper Assembly NIO WIN N REPLACEMENT WIRING STANDING PILOT COUNTERFLO MODELS CF353C H amp CF354C H Black 17 1 2 Fork Term with Stripped end Transformer 24 V Side to The 78200 Black 27 Flag Terminal Flag Terminal Auxiliary Limit Switch to Valve 78205 Wiring Harness 78250 MODELS CF503C H amp CF504C H Black 17 1 2 Fork Term with stripped end Transformer 24 V to Therm Black 32 Flag Terminal Flag Terminal Auxiliary Limit Switch Valve Black 6 Flag Terminal Flag Termial Selector Switch Fan Switch Wiring Harness MODELS CF653C H amp CF654C H Black 17 1 2 Fork Term with stripped end Transformer 24 V to Therm Black 32 Flag Terminal Flag Terminal Auxiliary Limit Switch Valve Black 6 Flag Terminal Flag Terminal Selector Switch to Fan Switch Wiring Harness REPLACEMENT WIRING 1 1 0 INTERMITTENT IGNITION COUNTERFLOW MODELS CF357C H amp CF358C H Black 17 1 2 Fork Term with stripped end Transformer 24V Side to Th Black 30 Flag Terminal Straight Terminal Auxiliary limit to ignition control Wiring Harness MODELS CF557C H am
12. accessibility clearances for servicing FIGURE 2 4 Minimum and proper operation Minimum clearance from cabinet to combustible construction Side Wall 4 Floor 0 Ceiling 4 See Figure 2 The unit may be recessed and rest directly against side studs and the inside surface of the rear wall ELECTRICAL ROUGH IN Rough in 115 v wiring terminating inside the junction box located on top of header plate for recessed or in areceptacle box not provided for flush mount Consult local codes or ordinances See Figure 3 MODEL NUMBER AMPS CF353C CF354C 1 95 CF503C CF504C 225 CF653C CF654C 225 57 2 2 58 2 25 557 2 5 558 2 55 Page 6 GAS ROUGH IN Check local codes for requirements as to the size and type of gas line required See Figure 5 for location of gas inlet holes in furnace cabinet Compounds used on threaded joints of gas pipe should be resistant to the action of liquefied petroleum gases The gas line joints must be checked for leaks This should be done with a soap solution watching for bubbles on all connections NEVER USE AN EXPOSED FLAME TO CHECK FOR LEAKS A manual valve equipped with a 1 8 NPT plugged tapping accessible for test gauge connection should be installed immediately upstream of the gas supply connection to the appliance Some codes and ordinances require that the manual valve be located outside the appliance See Figure 4 The applia
13. openings in drywall as shown in Figure 12 Position plasterground as shown in Figure 12 Optional Cut out and remove embossed section on casing rear Remove knockout on inner liner Put heater into position Place inner boot into position mark and cut boot flush with wall Place damper into cutout end of inner boot mark 4 holes from damper onto inner boot top and bottom and drill 4 1 8 hole Place outer boot into position mark and cut boot flush with wall Attach inner boot to liner Attach damper to inner boot screws provided Attach outer boot to casing back Place grill in position and secure to wall Final installation will appear as Figure 14 FIGURE 15 Qo c co 10 11 12 REAR DISCHARGE KIT Recessed Use optional kit No 407RR A Cut openings in wall as shown in Figure 13 Cut out and remove embossed section on casing rear Remove knockout from inner liner Place inner boot from kit through opening matching flanges of boot and knockout Mark screw holes and remove boot Drill holes with a 1 8 drill Repeat steps 5 amp 6 for outer boot After unit has been set in wall shove the inner boot through the back wall and up against the liner Secure boot with screws provided Attach damper to inner boot with screws provided Repeat Step 9 for outer boot Place grille in place and secure to wall Final installation will appear as Figure 15 OPTIONAL KITS CONTINUED
14. outlined above Appliance undersized 2 Incorrect supply pressure Too much heat 1 Combination control valve sticks open 1 Replace combination control valve Burner won t turn on TROUBLE SHOOTING CHART PILOT AND VALVE Gas valve not turned on Turn gas valve to position No voltage to valve Check for 24 Volts to Valve Defective thermostat Check wall thermostat No 115 Volt Line Voltage Jump fan switch to check for voltage fan will come on 5 Push on red buton to close Push red button in to close Auxiliary limit switch open Blocked flue switch open __Gas valve defective Page 18 TROUBLE SHOOTING CHART PILOT AND VALVE CONTINUED CORRECTIVE ACTION Air in line Bleed line Defective thermocouple Replace thermocouple Pilot flame too low Adjust pilot flame Manual reset switch not engaged Push on button Sparker won t work Check wire connections Sparker won t light pilot 2 a Pilot flame too lean 2 b Turn valve to position 2 c Check for pilot restriction Manual reset switch not engaged 3 Push on button THE FOLLOWING IS A LIST OF POSSIBLE CAUSES AND CORRECTIVE ACTIONS FOR BLOCKED FLUE SWITCH PROBLEMS 1 Blockage in vent pipe 1 A Check vent pipe for blockage such as bird nest wasp nest twigs leaves etc B Check inside the bottom of the vent pipe to make sure the top of the dra
15. pipe into the base plate Nail second ceiling plate spacer in place See Figure B STEP 6 If the vent continues through additional stories within the 2x4 stud space then fire stop spacers must be installed at the second and subsequent ceiling levels See Figure C STEP 7 To place furnace into position grasp furnace and lift so furnace flue vent and header plate vent opening engage Plug power cord from top of heater into receptacle on bottom of the header plate see Figure 3 Run thermostat wire through a drilled hole into an adjacent stud space Do not route it behind the header plate To do so may cause the thermostat wiring to chaff resulting in the appliance operating continually Connect thermostat wire with thermostat wires extending from top of heater Lift furnace upward and swing bottom into wall see Figure 7 Secure furnace in place using 2 holes provided in bottom of casing STEP 8 Make gas connection using connector the same size as gas connection of furnace CHECK ALL CONNECTIONS FOR GAS LEAKS WITH LEAK DETECTOR SOLUTION DO NOT USE OPEN FLAME STEP 9 Replace and fasten front panels to furnace NOTE FOR PROPER COMBUSTION MAKE SURE UNITS ARE LEVEL FRONT TO BACK AND SIDE TO SIDE INSTALLATION WHEN INSTALLED FLUSH TO WALL STEP 1 After locating furnace cut 3 1 2 x12 rectangular hole in ceiling between ceiling joists Make sure gasket is in position on the top of the furnace casing around the flue vent opening
16. single wall pipe When venting into a masonry chimney the chimney must be properly lined and sized for this gas furnace The use of type B or a flexible chimney liner is recommended Incorrect header plate Consult Figure 6 for correct header plate height location Vent pipe not down on the You must use a base plate obtained from the vent pipe manufacturer on top of the header plate securely header plate or wall furnace This will lock the vent pipe down and prevent the draft diverter from shoving it up Check the connections on both the switch and the gas valve Tighten if necessary DO NOT BYPASS THE BLOCKED FLUE SWITCH TO DO SO COULD EXPOSE THE CONSUMER TO PROPERTY DAMAGE PERSONAL INJURY OR POSSIBLE DEATH Page 19 COUNTERFLOW WALL FURNACE STANDING PILOT Prices and specifications subject to USE ONLY FACTORY SUPPLIED change without notice All REPLACEMENT PARTS prices are F O B factory Ss MODELS a L P GAS 89 5 CF354C H CF503C H CF504C H CF653C H CF654C H Llid i 1 e of NE CONTROL ASSEMBLY Le s L ey Lact and Mr Contractor we only sell parts through our wholesalers but the prices listed are for your convenience For prompt parts service contact the REV 03 05 wholesaler from which you purchased your Cozy heater NOTE Parts amp Page
17. under water Immediately call a qualified service technician to inspect the wall furnace and to replace any part of the control system or any gas control which has been under water 7 Have your fan type wall furnace and vent system inspected at least annually by a qualified service agency 8 Before cleaning or servicing the wall furnace turn off the gas and allow it to cool This will prevent burns 9 Due to high temperatures the furnace should be located out of traffic and away from furniture and draperies 10 Children and adults should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition 11 Young children should be carefully supervised when they are in the same room as the furnace 12 Clothing or other flammable material should not be placed on or near the furnace 13 Any safety screen guard or gill removed for servicing must be replaced prior to operating the furnace 14 Locate the blocked flue switch and the auxiliary limit switch and push in the reset button This will reset the switch in case it accidentally opened during shipping READ CAREFULLY BEFORE INSTALLING UNIT These installation instructions are a general guide and do not supersede applicable local codes and ordinances Before planning or making the installation be sure it complies with all phases of the local heating code Or in the absence of local codes the latest edition of the National F
18. 00 88 7 8 SW FIGURE 6 FIGURE 7 Page 8 Installation of B W Gas Vent for one story buildings or for Ceiling plate spacers to center En first floor of multi story B W Gas Vent in stud space for each subsequent ceiling or us Ven buildings nail securely at both ends floor level of multistory buildings as veni Installation of B W Gas Vent Firestop spacers supplied by manufacturer of B W Plate cut away to provide passage Plate cut away for full P of B W Gas Vent width of stud space to provide ventilation Studs on 16 inch centers Sheet metal screw base plate to header Use manufacturer s method of fastening pipe to base plate Header plate of vented wall furnace also acts as firestop FIGURE B FIGURE C Nail firestop spacer securely NATURAL GAS CONTROLS SPECIFIC ELEVATIONS All controls are pre assembled at the factory The normal Model Oto 2 000 4 000 6 000 manifold pressure should be 3 5 w c for Natural Gas and No 2 000 4 000 6 000 8 000 10 w c for L P Gas The maximum inlet pressure in the CF353C 34 36 gas supply pipe should never exceed 7 0 w c for Natural CF357C 34 36 Gas or 14 w c for L P Gas The minimum inlet pressure CF503C 3 4mm 31 in the gas supply pipe should never be lower than 4 5 CF557C 29 30 w c for Natural Gas or 11 w c for L P Gas CF653C 26 27 Model 0 to 2 000 No 2 000 4 000 CF354C 50 CF358C 50 504 45 HONEYWELL HONEYWELL
19. 4 28 80 Bottom Louver Assembly w Insulation 30100 31 60 30100 31 60 30100 31 60 Upper Front Shield 10 30250 3 50 30250 3 50 30250 3 50 Switch Box 11 30252 7 10 30450 7 20 30450 7 20 Switch Box Cover 12 30253 2 80 30253 2 80 30253 2 80 Lower Front Shield 13 30256 5 10 30256 5 10 30256 5 10 Motor Mounting Bracket 14 30079 2 10 30079 2 10 30079 2 10 Junction Box Cover 15 30033 3 70 30033 3 70 30033 3 70 Burner 16 72107 38 20 72107 38 20 72107 38 20 Valve VR8200H 1004 NATURAL GAS Honeywell 17 78090 125 00 78090 125 00 78090 125 00 Valve VR8200H 1137 L P GAS Honeywell 18 78091 129 20 78091 129 20 78091 129 20 Wiring Harness 19 78250 23 50 78251 23 50 78257 26 90 Manifold 21 78006 12 30 78006 12 30 78006 12 30 Orifice NATURAL 22 72182 3 40 78160 3 40 78169 3 40 Orifice L P 23 95271 3 40 78163 3 40 95273 3 40 Fan Motor 24 72108 73 90 78111 85 80 78111 85 80 Fan Blade 25 78101 24 20 78101 24 20 78101 24 20 Rubber Grommet 26 78010 3 00 78010 3 00 78010 3 00 Limit Switch 60T11 L180 27 78065 5 90 78065 5 90 78065 5 90 Fan Switch 60T12 F120 28 78067 6 10 78067 6 10 78067 6 10 Speed Switch 60T13 F160 30 29 N A N A 78066 8 90 78066 8 90 Auxiliary Limit Switch 60T15 L350 30 78086 9 30 78086 9 30 78086 9 30 Thermostat 24 Volt 31 78355 20 00 78355 20 00 78355 20 00 Transformer 32 78069 23 50 78069 23 50 78069 23 50 Flue Pipe Adapter 32b 40061 2 00 40061 2 00 40061 2 00 Plug Bracket 32
20. 70 22 30 30070 22 30 Lower Back Assembly le 30219 30 60 30219 30 60 Bottom 1f 30246 9 80 30246 9 80 Liner Assembly 2 30120 73 30 30550 80 20 Header Assembly Complete 3 31399 38 60 31399 38 60 Heat Exchanger Assembly 4 30133 210 60 30562 217 20 Draft Diverter Assembly 5 30180 31 30 30400 42 30 Fan Shroud Assembly 6 30200 21 60 30200 21 60 Top Louver w Insulation 7 30087 17 60 30087 17 60 Center Front Panel w Insulation 8 30089 24 90 30534 28 80 Bottom Louver Assembly w Insulation 9 30100 31 60 30100 31 60 Upper Front Shield 10 30250 3 50 30250 3 50 Switch Box 11 30252 7 10 30450 7 20 Switch Box Cover 12 30253 2 80 30253 2 80 Lower Front Shield 13 30256 5 10 30256 5 10 Motor Mounting Bracket 14 30079 2 10 30079 2 10 Junction Box Cover 15 30033 3 70 30033 3 70 Burner 16 72107 38 20 72107 38 20 Wiring Harness 17 78259 23 50 78257 26 90 Valve NATURAL LID VR8204H 1006 19 78092 122 90 78092 122 90 Valve L P LL D VR8204H 1014 20 78093 122 90 78093 122 90 Manifold 21 78006 12 30 78006 12 30 Orifice Natural 22 72182 3 40 78161 3 40 Orifice L P 23 95271 3 40 78168 3 40 Fan Motor 24 72108 73 90 78111 85 80 Fan Blade 25 78101 24 20 78101 24 20 Rubber Grommet 26 78010 3 00 78010 3 00 Limit Switch 27 78065 5 90 78065 5 90 Fan Switch 60T12 F120 28 78067 6 10 78067 6 10 Speed Switch F160 30 29 N A N A 78066 8 90 Auxiliary Limit Switch 60TG15 350 Deg Lower 30 78086 9 30 78086 9 30 Therm
21. CF558C 2 15mm VR8200H SERIES VR8204H SERIES CF654C 42 STANDING PILOT ILD PILOT FIGURE 10 A FIGURE 10 B The appliance is orificed at the factory for elevations up to 2 000 feet If installed above 2 000 feet the BTU input must be reduced 4 per 1 000 feet See the following orifice chart for the proper orifice for a specific elevation PILOT ADJUSTMENT Locate the pilot adjustment screw on the valve The pilot flame should surround at least the top 3 8 of the powerpile pilot generator or flame sensor see Figure 8 The pilot is unregulated so it will be operating at inlet line pressure maximum 7 w c for Natural Gas and 11 w c for Propane Gas To decrease the pilot flame turn the screw STANDING PILOT LLD PILOT clockwise approximately six full tums to bottom of pilot FIGURE 8 A FIGURE8 B light channel until you produce sufficient flame at the minimum noise level Screw PILOT FLAME ADJUSTMENT PILOT FLAME SHOULD ENVELOP 3 8 TO gt INCH OF THE TIP OF THE GENERATOR Page 9 CF353C H CF354C H CF503C H CF504C H CF653C H CF654C H STANDING PILOT FOR YOUR SAFETY READ BEFORE LIGHTING WARNING If you do not follow these instructions exactly a fire or explosion may result causing property damage personal injury or loss of life This appliance has a pilot which must be lighted by hand When lighting the pilot follow these instruc tions exactly BEFORE LIGHTING smell all around the appliance area f
22. RE LIGHTING WARNING If you do not follow these instructions exactly a fire or explosion may result causing property damage personal injury or loss of life This appliance is equipped with an ignition device which automatically lights the pilot Do not try to light the pilot by hand BEFORE OPERATING smell all around the appliance area for gas Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electric switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Use only your hand to push in or turn the gas control knob Never use tools If the knob will not push in or turn by hand don t try to repair it call a qualified service technician Force or attempted repair may result in a fire or explosion Do not use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water PN 91214 02 05 LIGHTING INSTRUCTIONS STOP Read the information on the safety label Set thermostat to lowest setting Turn off all electric power to the appliance This appliance is equipped with an ignition device w
23. Y FROM ANY COMPONENT OR FROM THE USE THEREOF THE REMEDIES SET FORTH HEREIN SHALL BE THE EXCLUSIVE REMEDIES AVAILABLE TO THE USER AND ARE IN LIEU OF ALL OTHER REMEDIES SOME STATES DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS SO THE ABOVE LIMITATIONS MAY NOT APLY TO YOU SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES SO THE ABOVE LIMITATIONS OR EXCLUSIONS MAY NOT APPLY TO YOU THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS AND YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM STATE TO STATE TABLE A Warranty for gas appliance heat exchangers only Product Cozy Gas Fired Floor Furnace Cozy Gas Fired Wall Furnace Cozy Gas Fired Vented Console Heater Cozy Gas Fired Direct Vent Heater Cozy Gas Fired Counterflow Furnace Cozy Gas Fired Counterflow Direct Vent Furnace Cozy Gas Fired Direct Vent Baseboard Heaters Cozy Gas Fired Hi Efficient Direct Vent Wall Furnace Warranty Period 10 Years 10 Years 10 Years 10 Years 10 Years 10 Years 10 Years 10 Years LOUISVILLE TIN AND STOVE COMPANY P O Box 2767 Louisville Kentucky 40201 2767 V V V V V V V V V V V V V V V V V V V V V V V V Lon TATATATATATATATATAY
24. arranty unless when requested the user returns at the user s expense the component or product claimed defective to the manufacturer for inspection to enable the manufacturer to determine if the claimed defect is covered by this warranty No charges for freight labor or other expenses incurred in the repair removal or replacement of any product or component claimed to be defective will be paid by the manufacturer to the user and the manufacturer will not be liable for any expenses incurred by the user in remedying any defect in the product Service under this warranty is the responsibility of the installer In the event service under this warranty is needed the user of the product shall request such service directly from the installer If the user is unable to locate the installer the user should write directly to the manufacturer and the name of an alternative service source will be supplied The product safety registration card packed inside the appliance must be completed and returned to the factory THIS WARRANTY IS EXPRESSLY IN LIEU OF ANY OTHER WARRANTIES EXPRESS OR IMPLIED WHETHER WRITTEN OR ORAL ANY IMPLIED WARRANTY OF MERCHANTABILITY OR OF FITNESS FOR A PARTICULAR PURPOSE IS EXPRESSLY LIMITED TO THE DURATION OF THE MANUFACTURER S EXPRESS WRITTEN WARRANTY UNDER NO CIRCUMSTANCES SHALL THE MANUFACTURER BE LIABLE FOR ANY SPECIAL INDIRECT OR CONSEQUENTIAL DAMAGES OR EXPENSES ARISING DIRECTLY OR INDIRECTL
25. ate and the fan cycle until the thermostat is satisfied Page 12 TERMINAL BLOCK WIRING DIAGRAM FAN LIMIT SWITCH Brown FAN LIMIT SWITCH Brown SELECTOR POWER CORD Black SWITCH POWER CORD Black TRANSFORMER Black LIMIT SWITCH Blue SELECTOR SWITCH Black Black MOTOR Black MOTOR Black TRANSFORMER Black TRANSFORMER Black POWER CORD White f POWER CORD White P N91122 CF353C CF354C CF357C CF358C H CF503C CF504C 557 CF558C CF653C CF654C H CAUTION Label all wires prior to disconnection when servicing controls Wiring errors can cause improper and dangerous operation Verify proper operation after servicing AUXILIARY LIMIT SWITCH For your safety this furnace is equipped with a manual reset auxiliary limit switch In case of failure by the primary limit switch this switch will shut the valve down completely before unsafe temperatures are reached After a cool down period switch must be manually reset If outages persist call a qualified service person MAINTENANCE INSTRUCTIONS 1 Installation and repair must be done by a qualified service person The appliance should be inspected before use and at least annually by a professional service person More frequent cleaning may be required due to excessive lint from carpeting bedding material etc It is imperative that control compartments burners pilot burners circulating air passageways and venting systems of the applia
26. ciency requirements that result in lower stack temperatures WARNING Operation of this wall furnace when not connected to a properly installed and maintained venting system or tampering with the blocked flue switch can result in Carbon Monoxide CO poisoning and possible death SEELIST OF POSSIBLE CAUSES AND CORRECTIONS ON PAGE 19 All type B vents shall extend in a generally vertical direction with offsets not exceeding 45 degrees except that a vent system having not more than one 60 degree offset may be allowed Any angle greater than 45 degrees from the vertical is considered horizontal The total horizontal run of a vent 4 plus the horizontal vent connector shall be not greater k Blocked y Blocked than 75 percent of the vertical height of the vent me Flue Flue Switch Z Switch Any offsets used should be as far above the drafthood as possible to allow a venting action to begin before any restriction is encountered Draft Diverter Draft Diverter Relief Opening Relief Opening CF35 Series Counterflow CF50 55 65 Series Counterflow Page 4 COMBUSTION AND VENTILATION AIR When installed this gas appliance must be provided with fresh air for combustion ventilation and dilution of hot flue gases The minimum required volume of the area where the appliance is installed should be 50 cubic feet per 1 000 btu hr
27. ected to provide longer life to the heat exchanger may smoke slightly upon initial firing Please provide adequate ventilation if this occurs This unit is not approved for installation in mobile homes greenhouses or environments involving dusty wet corrosive or explosive conditions Such conditions will invalidate the warranty and may create unsafe conditions CONTENTS Contents eire Fe rece E 2 Lighting amp Re hoa UR User qua ETE MK 10 11 Introduction 2 Operation Specifications 2 Terminal Block Wiring Diagrami 13 Safety Rules oce nre epo 3 Manual Reset 2 eno eot 13 Helpful Installation Information 3 Maintenance 13 Connecting the Vent esee 34 Wiring Diagram O E A Combustion and Ventilation Air sss 5 Side amp Rear Kits Mss ese tesis ets snes sae da 16 17 Furnace 22222 6 Trouble Shooting 2 18 19 Rough In Instructions eene 6 7 Repair Parts break 20 24 Installation 8 Repair Parts 1186 2 21 25 Controls dede emi 19 Warantys
28. er 4 000 btu hr of total input rating of all gas appliances See Figure B and C If horizontal ducts are used the minimum free area shall be one square inch per 2 000 btu hr of total input rating of all gas appliances Fresh make up air can also be provided through a duct to one permanent opening commencing within 12 inches of the ceiling The minimum free area of this opening shall be one square inch per 3 000 btu hr of the total input rating of all gas appliances but not less than the sum of the areas of all vent connectors in the space See Figure D When calculating the amount of fresh air needed you must include make up air requirements for the operation of exhaust fans kitchen ventilation systems clothes dryers and fireplaces Additional information can be found in the latest edition of ANSI 7223 1 National Fuel Gas Code Page 5 gt MACOS e mmscao m D A m o m ALL COMBUSTION AIR FROM ADJACENT INDOOR SPACES THROUGH INDOOR COMBUSTION AIR OPENINGS UL Listed Vent Cap Opening Opening ALL COMBUSTION AIR FROM OUTDOORS INLET AIR FROM VENTILATED CRAWL SPACE AND OUTLET AIR TO VENTILATED ATTIC UL Listed Vent Cap Listed Gas Vent Ventilation Louvers each end of attic Outlet Air Inlet Air Ventilation Louvers for unheated crawl space ALL COMBUSTION AIR FROM OUTDOORS THROUGH VENTILATED ATTIC UL Listed Vent Cap UL Listed Gas Vent Ventilation Louvers each
29. ft diverter did not rip the inner liner causing it to block part of the vent opening C Check that no insulation from the header plate got caught on top of the draft diverter when the heater was inserted into the wall D Check that the vent cap is properly installed not shoved too far down on the vent pipe 2 Burner is overfiring A Check the manifold pressure B Check the rate NOTE This appliance was orificed for elevations up to 2 000 feet When installed at higher elevations refer to orifice chart in Controls section of instructions for proper orifice size 3 Improper vent system Correct vent system A Vent too short A The vent should terminate a minimum of 12 feet above the floor See Figure 1 Also the top of the vent must be at least 2 foot above any obstacle within a 10 foot radius including the roof See Figure A on Page 4 B Restriction in vent B All type B vents shall extend in a generally vertical direction with offsets not system caused by exceeding 45 degrees except that a vent system having not more than one 60 offsets degree offset may be allowed Any angle greater than 45 degrees from the vertical is considered horizontal The total horizontal run of a vent plus the horizontal vent connector shall be not greater than 75 percent of the vertical height of the vent C Incorrect vent pipe C Use listed BW type vent pipe Do not use transite or any other type of ceramic pipe for venting Do not use
30. ge regulator if propane maximum 7 w c for Natural and 11 w c for propane 2 Clean burner ports do not enlarge ports 3 Check gas supply inlet pressure Check gas outlet manifold pressure for minimum step pressure for step pressure chart see Operation 4 Supply piping inadequately sized or incorrect inlet pressure 5 Eliminate drafts 6 See Venting Chimney or flue obstruction Drafts around appliance Pilot flame too small Burner ports clogged near pilot Low gas pressure 4 Pilot decreases in size when main burners come on Drafts around appliance 5 6 Bad venting 1 Open all manual gas valves 2 Defective gas valve 2 Replace gas valve Defective or sticking automatic valve 2 Excessive gas pressure The supply gas pressure must not exceed 1 2 psi or 14 w c Gas input not checked 2 Clogged orifice 1 Replace valve To correct this situation contact the utility supplying the gas Re check gas input Check orifice for clogging If clogged clean out the hole carefully with a smooth wood toothpick Do not in any way enlarge or distort it This is especially true when a dwelling or room is enlarged Have the heat loss calculated and compare to the appliance output approx 70 of input Your gas company or installer can supply you with this information If appliance is undersized replace with correct size unit 2 Check supply pressure as
31. hich automatically lights the pilot Do not try to light the pilot by hand Remove lower front panel Push in gas control knob slightly and turn clockwise to OFF Gas Control Knob NOTE Knob cannot be turned to OFF unless knob is pushed in slightly Do not force ve Wait five 5 minutes to clear out any gas Then smell for gas including near the floor If you smell gas STOP Follow B in the information on the safety label If you don t smell gas go to the next step Turn gas control knob counterclockwise to ON GAS CONTROL Replace lower front panel Turn on all electric power to the appliance Set thermostat to desired setting If the appliance will not operate follow the instructions TO TURN OFF GAS TO APPLIANCE and call your service technician or gas supplier PN 91214 02 05 TO TURN OFF GAS TO APPLIANCE 4 Push in gas control knob slightly and turn clockwise 7 Turn thermostat to it s lowest setting Turn off all electric power to the appliance if service is to be performed Remove lower front panel 5 Page 11 to OFF Do not force Replace lower front panel PN 91214 02 05 PROPER BURNER FLAME A proper flame will have a dark blue inner mantle that sits right on top of the burners with a lighter blue outer mantle rising above the burner See Figure 11 There may be some yellow where the pilot flame and burner flame meet There is no
32. ing 45 degrees except that a vent system having not more than one 60 degree offset may be allowed Any angle greater than 45 degrees from the vertical is considered horizontal The total horizontal run of a vent plus the horizontal vent connector shall be not greater than 75 percent of the vertical height of the vent Any offsets used should be as far above the drafthood as possible to allow a venting action to begin before any restriction is encountered Page 3 VENTING CONTINUED Height above any 10 or roof surface Less within 10 horizontally 2 Min i no WN e Ses Chimney__ Ses FIGURE A This appliance is equipped with a blocked flue switch WARNING Do not bypass the blocked flue switch To do so could expose the consumer to property damage personal injury or possible death Oval to round This switch when activated will interrupt the electrical circuit between adapter the transformer and the gas valve causing the main burner flame to extinguish The main burner will not re light until the blocked flue switch has been manually reset To reset the switch after locating it between the bottom of the fan shroud and the top of the draft diverter simply push the red button on top of the switch If the homeowner experiences this problem then the vent system must be checked and corrected NOTE An existing vent that has worked for years may not be adequate for today s appliances because of higher effi
33. lt Nat 65 000 V 14 5 416 Wx1044 Dx87 5 16 H 2 25 107 Lbs CF654C H 24 Volt L P 65 000 14 5 46 Wx10A4 Dx87 5 16 H 2 25 107 Ibs MODELS WITH INTERMITTENT IGNITION CF357C H 24 Volt Nat 35 000 4 14 5 16 Wx10 Dx78 5 8 22 95 Lbs CF358C H 24 Volt L P 35 000 4 VY 14 5 16 Wx10 4 Dx78 5 8 H 225 95 Lbs CF557C H 24 Volt Nat 55 000 4 14 5 46 Wx1044 Dx87 5 16 H 2 5 107 Lbs 558 24 Volt L P 55 000 4 7 14 5 6 Wx104 Dx87 5 16 H 2 55 107 Lbs Page 2 SAFETY RULES 1 Improper installation adjustment alteration service or maintenance can cause property damage bodily injury or death If you do not understand these instructions or your local codes call local authorities a qualified installer service agency gas supplier or the manufacturer 2 Do not install this fan type wall furnace in a recreational vehicle trailer or mobile home 3 Do not operate this fan type wall furnace unless it is connected to a properly installed and maintained vent system Do not exhaust flue gases into the room wall or attic space for any reason 4 Locate the thermostat in a room or space that cannot be separated by a door or other means from the room or space in which the front outlet grill is installed 5 Adequate air for combustion and venting must be provided 6 If rising water may enter the wall furnace turn off the gas immediately and disconnect the electric service Do not use the wall furnace if any part has been
34. n off the gas to the appliances and call your gas supplier from another location If your gas control has gotten wet as the result of flooding or other wetting it must be replaced immediately by a trained gas service technician Water can lead to damage of the internal safety mechanism in the gas control and can create a hazardous condition eee eee TD ARIRAN I Y The Louisville Tin amp Stove Co warrants to the original user the accompanying product for the period specified herein provided said product is installed operated maintained serviced and used according to the instructions and specifications accompanying the product AS OUTLINED IN OUR INSTRUCTIONS ANY WARRANTY CONSIDERATIONS ARE CONTINGENT ON INSTALLATION BY A QUALIFIED INSTALLER CONTRACTOR SELF INSTALLATION IS NOT RECOMMENDED AND MAY INVALIDATE YOUR WARRANTY If within a period of one year from the date of installation of the product any part supplied by the manufacturer proves to be defective due to workmanship or material it will replace such part provided parts have not been subjected to misuse alteration neglect or accidents The term of the warranty for the heat exchanger is covered in Table A below Any claim not made within ten 10 days after the expiration of the warranty period shall be deemed waived by the user The manufacturer shall have no liability or be required to perform any obligation under this w
35. n on the safety label If you don t smell gas go to the next step Locate red piezo ignitor button Locate pilot Follow metal pilot tube from gas control Turn gas control knob counterclockwise N to PILOT Push in pilot control knob and hold in Immediately begin a series of pushing and releasing the red piezo ignitor button while observing the pilot Continue to spark until pilotis lit Continue to hold the pilot control knob in for about one 1 minute after the pilot is lit Release the pilot control knob and it will pop back up Pilot should remain lit If pilot goes out repeat steps 5 thru 9 If knob does not pop up when released STOP and immediately call your service technician or gas supplier If the pilot will not stay lit after several tries turn the gas control knob to OFF and call your service technician or gas supplier Turn gas control knob counterclockwise to ON Replace lower front panel Turn on all electric to the appliance Set thermostat to desired setting PN91217 02 05 TO TURN OFF GAS TO APPLIANCE Turn thermostat to lowest setting Turn off all electric power to the appliance if service is to be performed Remove lower front panel Page 10 4 Push in gas control knob slightly and turn clockwise to OFF Do not force Replace lower front panel PN 91217 02 05 A 57 CF358C H 557 CF558C H LI D PILOT FOR YOUR SAFETY READ BEFO
36. nce be kept clean 2 The bearings of the motor should be oiled every six months with 5 20 oil 3 The appliance area must be kept clear and free of any combustible materials gasoline and other flammable vapors and liquids 4 It is essential that the flow of combustion and ventilation air not be obstructed 5 Periodic examination of the entire ventilation system as a routine part of the safety performance check is recommended on an annual basis IMPORTANT Keep burner and control compartment clean Vacuum burner compartment at the start of the heating season or as often as needed NOTE It is advised that the burner flames be checked at least twice during the heating season for any changes in burner flame characteristics 115 VAC 60 HZ Less than 12 Amps If any of the original wire as supplied with this appliance must be replaced it must be replaced with type thermoplastic 105 degree C wire or its equivalent Page 13 CF353C H 54 au Motor Limit Fan it m Switch Switch Auxiliary Limit Switch CF353C H CF354C H PICTORIAL SCHEMATIC FAN SWITCH LIMIT SWITCH TRANSFORMER THERMOSTAT CF353C H CF354C H LADDER SCHEMATIC AUXILIARY LIMIT SWITCH STANDING PILOT 503 504 CF653 654C H POWER THERMOSTAT CORD SWITCH 3 c LIMIT SELECTOR FAN SWITCH SWITCH SWITCH C AUXILIARY LIMIT SWITCH 503 504
37. nce and its individual shut off valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of psig The appliance must be isolated from the gas supply piping system by closing its individual manual shut off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 pig It is required by the National Fuel Gas Code that a drip line be installed near the gas inlet This should consist of a vertical length of pipe tee connected into the gas line that is capped on the bottom in which condensation and foreign particles may collect FIGURE 4 FIGURE 5 Page 7 INSTALLATION WHEN RECESSED UP TO 9 1 4 STEP 1 Cut out floor plate between 2x4 studs so heater will set flat on floor STEP 2 Make electrical connection of 115 V wiring into junction box provided on top of header plate STEP 3 Attach the base plate purchased with the vent pipe to the header plate using two No 8 sheet metal screws through the pre punched holes See Figure B STEP 4 Square up and nail header plate in place between 2x4 studs placed on 16 centers 14 3 8 between studs For distances from top of header plate to floor see Figure 6 STEP 5 Remove double ceiling plate between studs Install one ceiling plate spacer across the cut out in ceiling plate Install vent pipe into position be sure to lock bottom of vent
38. not follow the lighting instructions carefully or if you tamper with the gas control that you use to light the pilot Tampering with the gas control particularly with tools can damage the safety mechanism in the control and can allow gas to leak This can result in a fire or explosion causing property damage personal injury or death IF YOU SMELL GAS DON T LIGHT IT IF YOU CAN T LIGHT IT DON T FIGHT IT ACA La GAS American Gas C Association gama THIS IS NOT AN ADVERTISEMENT WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance CRITICAL SAFETY POINTS TO REMEMBER e Your gas has been odorized so that you can smell it Always smell around for gas before lighting your appliance e Sniff for L P gas at floor level LP gas is heavier than air and may temporarily exist at floor level i e Ifyou smell gas do not attempt to light the pilot Do not cause a spark by turning on or off electrical switches or appliances or by using the phone Tur
39. o inner liner Slide outer boot through wall from adjacent room and attach to casing side 9 Place grille into position and secure to wall FIGURE 17 14PEK A PLUG EXTENSION KIT INSTRUCTIONS FOR NON RECESSED INSTALLATION ONLY UNITS WITH TERMINAL BOARD Turn heater off following Section 3 in Lighting Instructions and allow to cool Turn off all electricity to heater Remove top louver assembly fan shroud and fan blade Loosen two screws on romex connector Remove junction box cover plate Disconnect three power cord terminals and pull power cord out of top of heater Insert power cord provided in kit through romex connector and plug onto terminal board following wiring diagram found in lighting and operating instructions Tighten two screws on romex connector Replace junction box cover plate STEP 10 Replace fan blade fan shroud and top louver assembly STEP 11 Snap 90 Degree outside corner Ref 1 onto 3 ft section Ref 2 plastic raceway Insert power cord and remove blue backing from adhesive strip on raceway and apply to side of heater See Figure 18 STEP 12 Insert power cord into second 3 ft section of raceway Ref 3 and remove blue backing and apply to side of heater butting up agianst bottom of other section See Fig 18 STEP 13 Cut 14 inch long bottom section to required length see chart insert power cord remove backing and apply to side of heater See Fig 18 STEP 14 Pl
40. or gas Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electric switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Use only your hand to push in or turn the gas control knob Never use tools If the knob will not push in or turn by hand don t try to repair it call a qualified service technician Force or attempted repair may result in a fire or explosion Do not use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water PN 91217 02 05 LIGHTING INSTRUCTIONS STOP Read the information on the safety label Set thermostat to lowest setting Turn off all electric power to the appliance Remove lower front panel Push in gas control knob slightly and and turn clockwise N to OFF NOTE Knob can not be turned from PILOT to OFF unless knob is pushed in slightly Do not force Pilot Control Knob Wait five 5 minutes to clear out any gas Then smell for gas including near the floor If you smell gas STOP Follow B in the informatio
41. ostat 31 78355 20 00 78355 20 00 Transformer 32 78069 23 50 78069 23 50 Flue Pipe Adapter 32b 40061 2 00 40061 2 00 Plug Bracket 32c 30047 1 90 30047 1 90 Casing Mounting Brackets 32d 30260 1 20 30260 1 20 Flue Pipe Gasket 33 78050 1 20 78050 1 20 Draft Diverter Gasket 34 78051 1 20 78051 1 20 Casing Top Gasket 34b 78049 1 20 78049 1 20 Element Support Gasket 35 78052 4 40 78052 4 40 Cozy Handle 37 84003 2 30 84003 2 30 Power Cord 38 78213 4 70 78213 4 70 Snap in Outlet 39 78058 4 70 78058 4 70 Thermostat Wire 41 74518 1 30 74518 1 30 Ignition Control Box S8600B 46 78097 128 00 78097 128 00 Pilot Assembly Electronic NAT 47 78098 29 80 78098 29 80 Pilot Assembly Electronic L P 48 78099 29 80 78099 29 80 Pilot Bracket CF IID 30299 2 40 30299 2 40 Flame Ignitor Assy Honeywell 49 78096 29 80 78096 29 80 Blocked Flue Switch 50 78108 9 30 78109 9 30 Blocked Flue Switch Wire 51 78230 81 50 78230 1 50 Terminal Board 52 78300 5 00 78300 5 00 Pilot Tubing w Fitting 78452 5 40 78452 5 40 Burner Pan Assembly 53 30286 15 90 30286 15 90 Valve Support Bracket Assembly 56 30290 4 70 30290 4 70 Pilot Mounting Bracket 57 30299 2 40 30299 2 40 Burner Mounting Plate 58 30296 2 80 30296 2 80 Lighting Instructions CF 91261 N C 91261 N C REV 03 05 REQUIRES TWO Page 23 MARCH 2005 PARTS LIST FOR ACCESSORIES FOR COUNTERFLOW WALL FURNACE PART DESCRIPTION REF NO PART NO LIST PRICE 16
42. p CF558C H Black 17 1 2 Fork Term with stripped end Transformer 24V to Thermo Black 38 Flag Terminal Straight Terminal Auxiliary limit to ignition control Black 6 Flag Terminal Flag Terminal Selector Swith Fan Switch Wiring Harness Mr Contractor we only sell parts through our wholesalers but the prices listed are for your convenience For prompt parts service contact the wholesaler from which you purchased your Cozy heater NOTE Parts amp schematic drawings on current models are shown at www cozyheaters com REV 03 05 Page25 MARCH 2005 IMPORTANT SAFETY BULLETIN ON YOUR GAS CONTROL AND PILOT LIGHT SYSTEM FOR HEATING EQUIPMENT WHAT YOU DON T KNOW CAN HURT YOU Your pilot light system has been designed for safe and reliable operation Although safety mechanisms are built in the potential for hazard exists This information is intended to help you avoid these hazards YOUR GAS CONTROL AND PILOT LIGHT SYSTEM Your gas control and pilot light system has a safety device whose purpose is to shut off the gas supply to the appliance if the pilot light goes out If you have trouble lighting the pilot or keeping it lit it may mean that this safety device is warning you that there is a problem with your system Inspection and repairs or replacement must be made by a trained gas service technician TAMPERING IS DANGEROUS The pilot safety system may also not work if you do
43. uctions CF 91272 N C 91272 N C 91272 N C REV 03 05 REQUIRES TWO Page21 MARCH 2005 COUNTERFLOW WALL FURNACE LI D PILOT Prices and specifications subject to change without notice All prices are F O B factory MODELS NAT GAS L P GAS 57 58 557 558 CONTROL ASSEMBLY USE ONLY FACTORY SUPPLIED REPLACEMENT PARTS Mr Contractor we only sell parts through our wholesalers but the prices listed are for your convenience For prompt parts service contact the wholesaler from which you purchased your Cozy heater NOTE Parts amp schematic drawings on current models are shown at www cozyheaters com Page 22 i dl A e Odli ds REV 03 05 HOW TO PROPERLY ORDER PARTS In addition to part description and part number please give model number serial number and type of gas used This information can be found on the rating plate that is attached to heater 24 VOLT SYSTEM WITH INTERMITTENT NATURAL CF357C H CF557C H MODEL NUMBERS L P CF358C H CF558C H REF PART LIST PART LIST PART DESCRIPTION NUMBER NUMBER PRICE NUMBER PRICE Casing Side Right 1 30055 48 40 30525 52 10 Casing Side Left la 30060 48 40 30530 52 10 Center Back Assembly 1b 30114 37 10 30544 36 80 Top Assembly 1 30025 13 30 30025 13 30 Upper Back Assembly 1d 300
44. uel Gas Code ANSI Z223 1 In Canada see latest edition of CAN1 B149 The appliance when installed must be electrically grounded in accordance with local codes or in the absence of local codes the latest edition of the National Electrical Code ANSI NFPA No 70 In Canada see latest edition of CSA C22 1 The ANSI standards are available from the American Gas Association 1515 Wilson Blvd Arlington Virginia 22209 The NFPA standards are available from the National Fire Protection Association Batterymarch Park Quincy MA 02269 Canadian standards are available from International Approval Services 178 Rexdale Blvd Etobicoke Ontario Canada MOW 1R3 VENTING This appliance must be properly connected to a venting system Consult local ordinances governing venting Install only UL listed type BW 4 oval gas vent When the vent enters the attic a listed type B 1 round flue pipe may be used See Figure 1 Page 4 Vent pipe must connect to the wall furnace or header plate with a vent base plate and terminate with a cap at a point at least 12 ft above the bottom of the wall furnace and two feet above any obstacle within a 10 foot radius and at least 3 foot above the roof Provisions must be made for adequate combustion and ventilation air This appliance must not be connected to a chimney flue serving a separate solid fuel burning appliance All type B vents shall extend in a generally vertical direction with offsets not exceed
45. ug power cord into wall receptacle see Fig 18 STEP 15 Light the heater following lighting instructions Page 17 TROUBLE SHOOTING CHART for qualified serviceman MAIN BURNER Flame too large Noisy Flame Yellow tip flame some yellow tipping on LP is permissible Delayed Ignition Failure to Ignite Condensation of Water Vapor Burner won t turn off Incorrect Gas Input Not enough heat POSSIBLE CAUSES CORRECTIVE ACTION 1 Replace complete valve 2 Check with local gas company for proper orifice size and replace 3 Refer to orifice chart on Page 9 1 Reduce pilot gas with adjusting screw on combination gas control valve 2 2 Remove burr or replace orifice do not enlarge orifices 3 3 See Flame Too Large above 1 Clogged main burner ports 1 Clean main burner ports Do not enlarge ports 2 Clogged draft hood 2 Clean draft hood 3 1 Defective operator section of gas valve Burner orifice too large If installed above 2 000 ft Noisy pilot Burr in orifice if it whistles or resonates Excessive gas input Linted up mixer opening 3 Check for dust or lint at air mixer opening Gas leak 1 Shut off gas service immediately Check piping Call gas company See For Your Safety Page 1 2 Clean flue 3 Eliminate drafts 1 Check pilot orifice Increase pilot gas flow if necessary by adjusting inlet pressure from gas source meter if natural gas or second sta