1. 8 6K32T amp 6K32TRC Switch it supports fiber optic C4 activity FULL HALF cable distances up to the IEEE standard 100Mbps distance limits i e typically 2km at full duplex and a 412m at half duplex The compact size of the LC Connector reduces the size of wiring panels in wiring closets while providing the advantage of future proof fiber optic technology The cable end is a plug in connector with both fiber strands terminated in one housing that cannot be improperly inserted Each port has an Activity ACT LED indicating packets being received a Link LK LED indicating proper connectivity with the remote device when lit and a FDX HDX LED indicating full duplex mode when lit or half duplex when off ww GarrettCom com ee 57 Magnum 6K32T amp 6K32TRC Managed Switch Installation and User Guide 05 07 5 2 8 6KP8 45LC Combo 4 100Mbps multi mode LC small form factor and 4 10 100 Mbps RJ 45 Connector The Magnum 6KP8 45LC Module is a combo module 4 Port 10 100Mbps amp 4 port 100Mbps with a combination of copper and Multi Mod LC ON Fiber Small Form Factor LC type ports The small size of LC connectors allows an advantage of F Da Lli i oh AA Ak AC rm LKE O ik amp Lk having more ports on one module The 6KP8 45LC is equipped with 4 10 100 RJ 45 ports and 4 LC UNK 2 PER Small form factor multi mode fiber ports G ACTIVITY 4 FULL HALF When installe
2. 100Mb Servers and Workstations 100Mb Servers a a and Workstations A D PE sarees 100Mb Servers and Workstations 10Mb Workgroup Magnum 6K32T amp 6K32TRC Managed Switch Installation and User Guide 05 07 The Magnum 6K32T Managed Switch equipped with copper and optional dual Gigabit fiber ports on modular slots provide an economical and seamless solution to the requirements The user configurable Magnum 6K32T provides an extra boost to the network requirements by providing copper fiber media along with the higher bandwidth support of 10 100 and 1OOOMb The user can utilize the SNMP feature equipped with VLAN Port security 802 1X and other security features to provide a secure and stable network as per the requirement The 6K32T Managed Switch with NEBS Level 3 compliance and management flexibility allows the user more than one configuration alternative The user has an advantage by fulfilling the present requirements as well as benefiting from the multiple choices of modules to support future expansion as the network evolves The dual Gigabit port option in the modular slot boosts the bandwidth for high speed to support the peak traffic and minimize congestion Example 3 Redundant Application 6K32TRC In a redundant application for high network availability where a rack mountable managed switch with over 24 ports is required with dense port features Magnum 6K32T s equipped with redundant LAN features like S R
3. and 100Mb be used whenever possible in order to provide flexibility in a mixed speed network since dual speed ports are auto sensing for either 10 and LOOMD s The following procedure describes how to connect a 10BASE T or 1 OOBASE TX twisted pair segment to the RJ 45 port The procedure is the same for both unshielded and shielded twisted pair cables 1 Using standard twisted pair media insert either end of the cable with an RJ 45 plug into the RJ 45 connector of the port Note that even though the connector is shielded either unshielded or shielded cables and wiring may be used 2 Connect the other end of the cable to the corresponding device 3 Use the LINK LED to ensure proper connectivity by noting that the LED will be illuminated when the unit is powered and proper connection is established _ www GarrettCom com 29 Magnum 6K32T amp 6K32TRC Managed Switch Installation and User Guide 05 07 NOTE for Power Substations In support of the IEEE 1613 Class 2 standard GCI advises that for substation applications the RJ 45 ports are intended for connectivity to other communication equipment such as routers or telecommunication multiplexers installed in close proximity i e less than 2 meters or 6 5ft to the 6K32 It is not recommended to use these ports in substation applications to interface to field devices across distances which could produce kigh greater than 2500V levels of ground potential rise GPR during line
4. ccceeeeeeeeeeees 54 5 2 4a 6KP6 RJ10ST FL ST type twist lock CONNECHOF eeeeeeeeee ees 55 5 2 5 6KP8 MTRJJ Small Form factor c cece ccececccceeseccceeeceeeeees 55 5 2 5a OKP6O MT10STmode FX Factor eecceeeecesscceeerceserrresrrrrerrrese 56 5 2 6 6KP8 45MT MTRJ Small Form Factor cc eee ceeeceeeeeee ee 57 32 7 6KP8 MLC LC connector Small cc cecccccceeececeeeeceeees 57 5 2 8 6KP8 45LC_ 10 100 Mbps RJ 45 Connector ccccceeeeeeees 58 5 2 9 6KP8 RJ45 Twisted Pair 10 100Mb 8 Port eee 58 5 2 10a New PoE Power Pass through P6KP8V RJ45 MDIX 666 59 5 2 10b New PoE Power Inside model PI6KP8 45RJ MDIX 60 5 2 11 O6KP8 45 2MT MTRJ Small Form Factor ce eeeeee 62 5 2 lla 6KP8 45 2LC single mode FX LC Small Form Factor 62 5 2 12 GBIC SXSC Gigabit fiber LOOOMb multi mode SC 62 5 2 12a GBPM 2OTX Two Gigabit Option cccceecccceeeseeseeeeees 63 5 2 12b GBIC LXSC Gigabit fiber LOOOMb multi mode SC 64 5 213 GIVE BNI pers ccnacicatesstesnansaxndnceadnosnactibnndtuauilenmnemsineduantitesavectiantedae 64 6 0 TROUBLESHOOTING cccsssscccssssssccccsssssccccsssscccccsssscccccssssccoees 65 6 1 Before Calling for ASSIStANCE cccccccccccsssssssessssseeececccceeeceeaaeeeeeseeees 65 6 2 When Calling for Assistance cccccccccecccecceeeeessseseeeeeeeeeeeeeeeeeeaas 66 6 3 Return M
5. female to female cable is required to communicate properly The Null Modem DB 9 cable is optional and can be order from the factory along with the unit as CONSOLE CBL for serial port CONSOLE USB for USB port NOTE for Power Substations In support of the IEEE 1613 Class 2 standard GCI advises that for substation applications the serial RJ 45console_ports are intended for temporary connectivity to other equipment such as PCs Since the console port connection is temporary it is excluded from IEEE 1613 packet loss testing per the 1613 standard defined test procedure 45 Magnum 6K32T amp 6K32TRC Managed Switch Installation and User Guide 05 07 4 0 OPERATION This chapter describes the functions and operation of the Magnum 6K32T amp 6K32TRC Switch 4 1 Switching Functionality A Magnum 6K32T amp 6K32TRC provides switched connectivity at Ethernet wire speed among all of its ports The Magnum 6K32T amp 6K32TRC support 10 100Mbs for copper media and 10 or 100Mb separate traffic domains for fiber ports to maximize bandwidth utilization and network performance All ports can communicate to all other ports ina Magnum 6K32T amp 6K32TRC but local traffic on a port will not consume any of the bandwidth on any other port Magnum 6K32T amp 6K32TRC units are plug and play devices There is no software configuring necessary to be done for basic operation at installation or for maintenance The only hardware configuration settings
6. Magnum 6K32T amp 6K32TRC Managed Switch Installation and User Guide 05 07 2 2 7 Packet Prioritization 802 1p QOS Quality of Service means providing consistent predictable data delivery to users from datagram paths that go all across a network As a LAN device the Magnum 6K32T amp 6K32TRC can do its part to prevent any QOS degradation while it is handling Ethernet traffic through its ports and buffers The Magnum 6K32T amp 6K32TRC switching hardware supports the IEEE 802 1p standard and fulfills its role in support of QOS giving packet processing priority to priority tagged packets according to the 802 1p standard In addition to hardware support for QOS the MNS software R3 supports two priority queues that can be shared across the eight levels of defined packet priorities for application specific priority control by the user through software configuration settings 2 2 8 Frame Buffering and Flow Control Magnum 6K32T amp 6K32TRC s are store and forward switches Each frame or packet is loaded into the Switch s memory and inspected before forwarding can occur This technique ensures that all forwarded frames are of a valid length and have the correct CRC i e are good packets This eliminates the propagation of bad packets enabling all of the available bandwidth to be used for valid information While other switching technologies such as cut through or express impose minimal frame latency they will also permit bad fr
7. used to secure a PM face plate in position but unscrew only four of the screws as shown in Fig below These screws are also used to secure the individual 6KPM cards screen plate which can be subjected to significant forces from the attached cables See Figure 3 5 1d Figure 3 5 1d Top View 6KPM retaining screws hold Face Plate 3 5 2 Installing 6KPM Cards in the Magnum 6K32T amp 6K32TRC Up to four front mounted 6KPM cards may be installed in one Magnum 6K32T amp 6K32TRC Managed Switch unit Follow these steps to install a 6KPM Step 1 Remove top chassis cover See procedure in Section 3 5 1 above Step 2 Placed Granddaughter board as shown in fig 3 5 2a and 3 5 2b on the chassis built in stand off female provided at the front of the 6K32T amp 6K32TRC Main Board and screw down tightly with the three 5 16 stand off male on the top of the Granddaughter board The 5 16 stand off has been used to place the daughter board on the top of the granddaughter board and latch it securely Fig 3 5 2b Granddaughter Board placed in modular slot and secured with three 7 16 stand off s as shown with arrow mark _ www GarrettCom com 40 Magnum 6K32T amp 6K32TRC Managed Switch Installation and User Guide 05 07 Step 3 The figure here illustrates the basic layout of an individual PM card 6KPM card fits into the space provided on the main board over the grand daughter Bd and the male latched cream color connector a
8. 2 Installing 6KPM Cards in the 6K32T amp 6K32TRC 0 40 3 5 3 Removing GRPM Cards ssssccvesseescnancctscnsadatecwaassvisosasesncecndeteceanes 43 3 6 Connecting the Console Terminal to 6K32T amp 6K32TRC 0 44 3 6 1 RS 232 DB 9 Console Com port Serial port pin 45 AO OPERA TON sas exsivssvecesaxseiusnvanuelawsesstussssedanseriacsvasstuscsbastesses 46 4 1 owitonne Funcional seisce nn n AE 46 4 2 a EE D penaa E A TEA 47 4 3 Auto Cross MDIX Auto neg for 10 100Mbps RJ 45 ports 47 ill Magnum 6K32T amp 6K32TRC Managed Switch Installation and User Guide 05 07 4 4 Flow control IEEE 802 3x standard oo eee eeceeccecceccecceeceeceecees 49 5 0 6K32T amp 6K32TRC MANAGED SWITCH PORT MODULES 49 5 1 Inspecting the Package and Product nennenneeennesssssssseseeeeeesssssssss 50 a 6KPM Module Description ccceccccccccccceeeeeeeeeeseeeseeeeeeeeeeeeeeeaaas 50 5 2 1 6KP6 RJMST multi mode FX ST twist lock Module 51 5 2 la 6KP6 RJIOST multi mode FX ST twist lock Combo 51 5 2 1b O6KP4 FIOST multi mode FX ST twist lock Module 52 5 2 lc 6KP4 FLSTFX multi mode FX ST twist lock Module 52 SUN 6KP6 RJMSC multi mode FX SC snap in Fiber connector 53 2 6KP6 RJSSC Mbps single mode FX SC type snap in 066 54 5 2 4 6KP6 RJSSCL FX SC type snap in Connector
9. 45 and 2 100Mb multi mode FX SC snap in Fiber connector The Magnum 6KP6 6KP6 RJMSC RIMSC ie dleo a Combo 6 Por 4 Port 10 100Mbps and 2 100 Mb SC Fiber Port module equipped with 4 10 100Mb RJ 45 ports along with 2 multi mode 100Mbps fiber optic transceivers all in one module This is Similar to the 6K6 RJMST It has the same LEDs indicating port G ACTIVITY 4 FULL HALF activity ACT Link LK and FDX HDX and 10 100 operation and the same face plate lettering While the functionality of these two modules is essentially the same the 6KP6 RJMSC is equipped with an SC type snap in connector instead of an ST type 53 Magnum 6K32T amp 6K32TRC Managed Switch Installation and User Guide 05 07 5 2 3 6KP6 RJSSC 4 10 100Mbps RJ 45 Ports and 2 100Mbps single mode FX SC type 6KP6 RJMSSC snap in connector The Magnum 6KP6 RJSSC 4 Port 10 100Mbps and 2 100 Mb SSC Fiber Port is also a Combo module equipped with 4 dual speed copper ports and 2 Single mode SC type connectors It O LINK 2 10 100 provides an advantage through combining copper 3 ACUVITY 4 FULL HALF and Fiber functions in one module of the 6K32T amp 6K32TRC Switch supporting four Copper and two single mode fiber network segments The 6KP6 RJSSC when installed in a Magnum 6K32T amp 6K32TRC Switch operates on copper at the 100m distance The Fiber is single mode and cable lengths can be as much as 25 Km see Power Bud
10. LED status indicators should be in plain view and easy to read Rack mount installation requires special 19 rack mounted brackets and screws included with each Magnum 6K32T amp 6K32TRC unit These brackets attach to the front sides of the ls r Fig 3 3 1 Dual Side Mountings for Magnum 6K32T amp 6K32TRC units waf fe E i TE Standard Flush 23 Mount Bracket Mid Range Mount or 5 Set Back Bracket Ce c Switch regular package not the Reverse version which is then typically fastened into a standard 19 RETMA rack as shown here The 23 brackets and the ETSI European metric approx 21 brackets are also available optional for rack mounting www GarrettCom com 34 Magnum 6K32T amp 6K32TRC Managed Switch Installation and User Guide 05 07 the Magnum 6K32T amp 6K32TRC Switches These brackets are popular in the Telco industry where they are a standard for Central Office rack mounting purposes The 23 and the ETSI brackets are mainly used for larger equipment These brackets are rack mounted in a frame typically accessed in operation from both sides The bracket mounting holes in the sides of the Magnum 6K32T amp 6K32TRC permits it to be mounted in various ways The same holes fit all three types 19 ETSI and 23 of brackets The mounting for the 23 is illustrated in Figure 3 3 1 below The brackets may be attached f
11. MT RJ connectors 6KP8 MLC SFF Fiber module w eight 100Mbps mm FX LC connectors 6KP8 SLC SFF Fiber module w eight 100Mbps sgl m FX LC connectors 6KP8 45MT 4 4 module w four RJ 45 ports and four 2km mm FX MT RJ s 6KP8 45MLC 4 2 module w four RJ 45 ports and four 2km mm LC connectors 6KP8 45SLC 4 4 module w four RJ 45 ports and four 15km Sm LC connectors 6KP6 MT10ST 4 2 module w four MTRJ ports and two 1OMb 2km FL ST s 6KP6 RJ10ST 4 2 module w four RJ 45 ports and two 1OMb 2km FL ST s 6KP8 45 2MT 6 2 module w six RJ 45 ports and two 2km mm MTRJ connectors Magnum 6K32T amp 6K32TRC Managed Switch Installation and User Guide 05 07 6KP8 45 2SLC 6 2 module w six RJ 45 ports and two 100Mb 15km sgl mode FX LC connectors Gigabit Options Modules using GBIC 6KP5 G4RJ G 4 module with one GBIC open transceiver and four 10 100 RJ 45 connectors includes front panel metal sheet 6KP3 G2SC G 2 module with one GBIC transceiver and two 100Mb 2km FX SC fiber ports connectors includes front panel metal sheet GBPM 20OTX Two port Gigabit module provides two GBIC open transceiver ports for a user selectable GBIC transceiver module GBPM COTX One slot Gigabit 6K module provides one GBIC open transceiver port for a user selectable GBIC transceiver module GBIC SXSC GBIC transceiver module for use in GBPM xOTX One 1OOOBASE SX port with multimode SC fiber connector GBIC LXSC10 GBIC
12. Supply Internal 48VDC Option DC Power Connector 3 terminals GND Input Voltage 36 70 VDC Power Consumption Same as for AC models see Section 1 1 Power Supply Internal 24 VDC Option Industrial Applications DC Power Connector 3 terminals GND Input Voltage 20 36 VDC Power Consumption Same as for AC models see Section 1 1 Power Supply Internal 125 VDC Option Industrial Applications DC Power Connector 3 terminals GND Input Voltage 88 150 VDC Power Consumption Same as for AC models see Section 1 1 With the exception of the power supply all specifications and functions of Magnum 6K32T amp 6K32TRC Switch 48VDC 24VDC and 125VDC models are identical to those listed in the main manual B2 0 48VDC 24VDC and 125VDC POWER THEORY OF OPERATION The 48VDC 24VDC and 125VDC power options are designed using diodes inside on each DC power input line behind the two external power connection terminals so that the power from an external POWER SWITCH a SUPPLY source can only flow into the hub FUS This allows the Switch to operate A only whenever DC power is CHASSIS 68 Magnum 6K32T amp 6K32TRC Managed Switch Installation and User Guide 05 07 correctly applied to the two inputs It protects the Switch from incorrect DC input connections An incorrect polarity connection for example will neither affect the Switch its int
13. The Power Pass through PoE modules are totally dependent upon the powerful 48VDC input power supply to support more RJ 45 10 100 ports Each port requires at least 15watts to power up the PoE PD devices In this Fig the top 8 RJ45 ports are enhanced with POE option The 8 RJ45 POE modules are also available with mix n match with fiber modules Please check the ordering information Sec 1 2 for all the various P6K PoE modules option 59 Magnum 6K32T amp 6K32TRC Managed Switch Installation and User Guide 05 07 P6KP6 RJ45 6 Port 10M00Mb Copper with POE ports E E QDkiacr 10mo0 C3 PoE C4 FULL HALF The LEDs on 6KP8 RJ45 PoE modules are slightly different compared to regular non PoE RJ 45 modules as shown in Fig 2 When the PoE port is in use the PoE LED is ON when connected properly to an 803 af compliant PD device on that port When non PoE devices are connected the PoE LED is OFF PoE does not affect operation of Ethernet data traffic LINK and ACTIVITY LEDS are combined on the PoE modules into one LED that is marked as LINK ACT as shown in the diagram PoE LEDs Summary e For PoE devices each RJ 45 PoE port supports only 802 3af complaint devices The PoE LED is ON when the attached PD is drawing power from the port e For non PoE devices connected the PoE port will act as a normal RJ 45 port and the PoE LED is OFF No power is being sent out from the port e The PoE ports in Magnum 6K s with 48V
14. Tree Protocol RSTP LLL S Ring Redundancy Mgr optional multi level QoS Port and Tag based VLANs GVRP IGMP Snooping SNMPc GUI support BootP and DHCP client for IP configuring Radius X TACACS etc E MDI MDIX Auto negotiating on RJ 45 ports for convenient cascading using straight RJ 45 cable E Support PoE module to provide power via RJ 45 cable on the modular slot 2 4 Applications Magnum 6K32T amp 6K32TRC Fiber Switches offer high performance along with one or two modular slot options to fulfill the choice of copper Fiber 10 100 or 1000Mb requirements The 6K32T amp 6K32TRC also offers MNS 6K management software loaded with multiple useful features The Magnum IEC61850 6K32T amp 6K32TRC Switches are used in a variety of Power sub stations applications including Industrials and temp un controlled secure VLAN performance upgrades to departmental networks and LAN traffic centers that require Gigabit backbone services The performance characteristic of the 6K32T amp 6K32TRC Switches enables them to inter connect a series of subnets one subnet per 6K32T Switch port in a LAN traffic center The subnet connections may be via fiber or twisted pair cabling 100Mbps or 10 Mbps speed and full or half duplex mode The mixed media capability in the modular slot is ideal for upgrading existing Ethernet LAN networks where existing cabling must be accommodated The fiber built in media capability provides future proof fiber cabling
15. delivery Inspect the contents of this package for any signs of damage and ensure that the items listed below are included This package should contain 6K32T amp 6K32TRC PMs Installation instructions with illustrations Remove the 6K32T amp 6K32TRC PM s from the shipping container Be sure to keep the shipping container should you need to ship any of the PMs separately at a later date In the event there are items missing or damaged contact your supplier If you need to return the unit use the original shipping container if possible Refer to Chapter 5 for specific return procedures 5 2 6KPM Module Description An important feature of the Magnum 6K32T amp 6K32TRC is the use of one Port Modules for flexible mixed media connectivity to RJ 45 and fiber media in the modular slot Since the Magnum 6K32T amp 6K32TRC Switches have dual speed capability for copper ports the 6 or 8 port interfaces are designed to support all standard Ethernet media types at 10 or 1OOMps speed Each 6K32T amp 6K32TRC PM can provide two four six or eight ports for connecting Ethernet segments with its individual connector type and media For a list of 6K32T amp 6K32TRC Port Module types refer to Section 1 2 Each 6K PM is individually described in the following sections NOTE The port 1 on the RJ 45 ports on all the modules either all RJ 45 ports or used for COMBO module is set as as other ports _ www GarrettCom com 50 Magnum 6K32T am
16. e f LKO Orik O Lk Ne is black in color The MT RJ s a N small size and ease of I pe eee fe connection make it a good choice for 100Mbps fiber to Q activity 2 FULL HALF the desktop Ethernet 3 LINK 55 Magnum 6K32T amp 6K32TRC Managed Switch Installation and User Guide 05 07 connectivity When installed in a Magnum 6K32T amp 6K32TRC Switch it supports fiber optic cable distances up the IEEE standard 100Mbps distance limits 1 e typically 2km at full duplex and 412m at half duplex The functionality of this OOBASE FX multi mode 8 Port module is essentially the same as the ST and SC types It has the same LEDs per port indicating port activity ACT Link LK and FDX or HDX operation 5 2 5a 6KP6 MTI0ST 4 100Mb multi mode FX MTRJ Small Form Factor and 2 10Mb Multi mode ST Fiber port The 6KP6 RJ1OST is a combo module with two different kinds of fiber flavor with two different speeds The top four ports of MTRJ Small form factor fiber support at 100Mb full duplex whereas the bottom two ports multi mode ST Fiber support 10Mb half duplex This combo module provides more flexibility to the user to connect their legacy 1OMb fiber as well as 1OOMb to the Magnum 6K32T amp 6K32TRC Switch When installed in a Magnum 6K32T amp 6K32TRC Switch the 100Mb MTRJ connector supports fiber optic cable distances up to the IEEE standard 100Mbps distance limits 1 e typically 2km at full duplex and 412m at
17. mm ST ports and with 4 RJ45 10 100 copper and 2 10Mb fiber mm ST ports The 4 RJ 45 2 10 Mb ST operation of the SFF fiber and the RJ 45 half of the module is as described for those port types above For detailed information about 1OMb mm ST fiber half of the module see Section 2 2 5 2 2 5 Four Port 10 Mb mm Fiber ST Modules 1 TX GLK RX TX GLK RX 5 TEE ee H F H 2 TX GLKRX ab The 4port 10Mb ST fiber modules behave the same as the 8 100Mb ST fiber modules except for the 10Mb speed For port numbering ports 1 2 5 6 are present ports 3 4 7 8 are not present The default setup on the 1OMb fiber module is half duplex which allows the Magnum 6K32T amp 6K32TRC Switch to connect to any 1OMb hub or media converter or almost any other device with a 1OMb fiber Ethernet port User mode control per port through the MNS software is the same as the other 6K32T amp 17 Magnum 6K32T amp 6K32TRC Managed Switch Installation and User Guide 05 07 6K32TRC modules The fiber ports support fiber cabling distances according to the 1OBASE FL standard i e 2km distance for multi mode fiber Single mode for up to 10Km distance may be available as a special order configuration 2 2 6 Gigabit 1000Mbps port modules The Magnum 6K32T amp 6K32TRC amp 6K32 s offer wide options for Gigabit speed with multiple choices for the modular slot The new Magnum 6K32T amp 6K32TRC can be configured with four Gi
18. modular slot to confirm the successful installation before placing the chassis cover 3 6 Connecting the Console Terminal to Magnum 6K32T amp 6K32TRC Management Use a DB 9 null modem cable to connect the Magnum 6K32T amp 6K32TRC Console Port the RS 232 port on the 6K32T amp 6K32TRC Switch to the your PC so that your PC becomes the 6K32T amp 6K32TRC s Console Terminal Note The DB 9 cable does not include with the 6K32T amp 6K32TRC unit package Console DB 9 Port CONSOLE cy Rear View of Magnum 6K32T Note For detail description of Managed Network Software MNS 6K and Magnum 6K32T amp 6K32TRC Switch configuration for Network Management please refer to Magnum 6K32T amp 6K32TRC Software Manual available on GarrettCom s FTP site Detail info about the MNS is available on 2 2 9 see page no 13 of this manual 44 Magnum 6K32T amp 6K32TRC Managed Switch Installation and User Guide 05 07 3 6 1 RS 232 DB 9 Console Com port Serial port pin assignments DB 9 Console port connector Pin Signal Description 1 CD Carrier detect not used 2 RXD Receive Data input 3 TXD Transmit Data output 4 open not used 5 GND Signal Ground 6 9 open not used The above provided information enables a managed station a PC or Console terminal to connect directly to the switch using a straight through cable Note For using Console port to configure the managed switch a serial Null modem
19. power requirements to prevent overloading of the building s electrical circuits 5 If the equipment is mounted in an enclosed or multiple rack assembly verify that the equipment has a reliable and uncompromised earthing path 6 24vdc 48vdc and 125vde must be installed in restricted access locations 7 CB Circuit breaker of 10Amps should shown on top of Rack This section describes installation of the Magnum 6K32T Switches as well as connection of the various Ethernet media types 3 1 Locating Magnum 6K32T Switches The location of a Magnum 6K32T Switch is dependent on the physical layout of the network Typically the Switch is placed in a central wiring location where groups of network devices need to be connected in order to communicate with each other These Switches are typically rack mounted in a wiring closet see Section 3 3 2 below but because they have rubber feet they can also be installed on a shelf or table top unit The compact size allows it to be easily placed in an office or lab area and it can also be either shelf of wall mounted see Section 3 3 1 below Locate an AC receptacle that is within six feet 2 meters of the intended Magnum 6K32T site The E mmi rugged metal case of the Magnum 6K32T will normally ihe i i oc a 3 protect it from accidental damage in a lab or workplace i Wa j i je i We i setting Maintain an open view of the front to visually Pr samt ey uh monitor the status LEDs Keep an ope
20. to ground fault conditions The 6K32 passes the 1613 specifications for zero packet loss with fiber ports amp with RJ45 ports used as indicated here 3 2 5 Connecting Twisted Pair CAT 5e or better Unshielded or Shielded The RJ 45 1OOOBASE TX Gigabit ports of the Magnum 6K32T amp 6K32TRC can be connected via copper media with the following minimum specifications 1O00BASE T CAT 5e or for better results 100 ohm UTP shielded twisted pair STP balanced cable The CAT 5e or the more effective 100 ohm UTP shielded twisted pair STP balanced cable is recommended when making 1OOOBASE TX connections In either case the maximum distance for unshielded twisted pair cabling is 100 meters 328 ft Media IEEE Standard Connector Twisted Pair CAT 5e 1O000BASE T RJ 45 NOTE It is recommended that high quality CAT Se cables which work for both 100 Mb and 1000Mb be used whenever possible in order to provide flexibility in a mixed speed network The following procedure describes how to connect a 1OOOBASE T twisted pair segment to the RJ 45 port The procedure is the same for both unshielded and shielded twisted pair cables 1 IOOOBASE T connections require that all four pairs or wires be connected Insert either end of the cable with an RJ 45 plug into the RJ 45 connector of the port Note that even though the connector is shielded either unshielded or shielded cables and wiring may be used 2 Connect the other end of the cable to the c
21. transmitting device is commanded to stop transmitting into the 6K32T amp 6K32TRC Switch port for sufficient time to let the Switch reduce the buffer space used When the available free buffer queue increases the Switch will send a RESUME packet to tell the transmitter to start sending the packets Of course the transmitting device must also support the 802 3x flow control standard in order to communicate properly during normal operation Note When in Half Duplex mode the 6K32T amp 6K32TRC Switch implements a back pressure algorithm on 10 100 Mb ports for flow control That is the switch prevents frames from entering the device by forcing a collision indication on the half duplex ports that are receiving This temporary collision delay allows the available buffer space to improve as the switch catches up with the traffic flow 5 0 Magnum 6K32T amp 6K32TRC Managed Switch Port Modules This chapter describes each Port Module PM including appearance functionality and status displays 49 Magnum 6K32T amp 6K32TRC Managed Switch Installation and User Guide 05 07 5 1 Inspecting the Package and Product This section applies only to PMs shipped as separate items 1 e 6K32T amp 6K32TRC PMs not factory installed ina Magnum 6K32T amp 6K32TRC modular slot Examine the shipping container for obvious damage prior to installing a 6K32T amp 6K32TRC PM notify the carrier of any damage you believe occurred during shipment or
22. unknown contact GarrettCom Inc by fax phone or email support garrettcom com for assistance 6 2 When Calling for Assistance Please be prepared to provide the following information 1 A complete description of the problem including the following points a The nature and duration of the problem b Situations when the problem occurs c The components involved in the problem complete Network diagram preferred d Any particular application environment power spike that when used appears to create the problem 2 An accurate list of GarrettCom product model s involved with serial number s Include the date s that you purchased the products from your supplier 3 It is useful to include other network equipment models and related hardware including personal computers workstations terminals and printers plus the various network media types being used 4 A record of changes that have been made to your network configuration prior to the occurrence of the problem Any changes to system administration procedures should all be noted in this record 6 3 Return Material Authorization RMA Procedure All returns for repair must be accompanied by a Return Material Authorization RMA number To obtain an RMA number please use this URL https rma garrettcom com rma rma_request_noaccount php to fill out the form Please have the following information readily available Name and phone number of your contact p
23. with any RJ 45 device and eliminate the use of cross over cable The RJ 45 pins normally TP crossover switch are per the standard for hubs to users twisted pair wiring 1 receive 2 receive 3 transmit 6 transmit other pins not used When the TP crossover push button is UP the pins of the RJ 45 port are per the standard for up links using twisted pair wiring 1 e the transmit and the receive pairs are exchanged transmit 2 transmit 3 receive 6 receive other pins not used NOTE for Power Substations In support of the IEEE 1613 Class 2 standard GCI advises that for substation applications the RJ 45 ports are intended for connectivity to other communication equipment such as routers or telecommunication multiplexers installed in close proximity i e less than 2 meters or 6 5ft to the 6K32 It is not recommended to use these ports in substation applications to interface to field devices across distances which could produce kigh greater than 2500V levels of ground potential rise GPR during line to ground fault conditions The 6K32 passes the 1613 specifications for zero packet loss with fiber ports amp with RJ45 ports used as indicated here 5 2 10a New PoE Power Pass through model P6KP8V RJ45 MDIX 10 100Mb 8 port The PoE RJ 45 ports act similar to regular RJ 45 ports except they have capability of providing power on each port to power up the PD devices per the TEEE802 3af PoE standard
24. with optional fiber port with auto negotiating full switching performance Quad Series Fiber Switches 100 amp 10Mbps fiber and copper ports mixed speed and mixed media types full switching performance mP62 and P62F Outdoor Ethernet SwitchES for temperature uncontrolled locations 6 10 100 and 2 100Mb fiber ports can be connected in strings Mixed Media Fiber Hub 16 port 10 100 auto sensing Dual Speed 8 port and 16 port 10 100 auto sensing HUBS Personal Switches 10 LOOMb 8 port dual speed Auto negotiable with fiber option Personal Hubs LOOMb or 10 LOOMb 8 port with 2 switched ports 1 fiber built in Personal Hubs 10Mb series 8 port AUI stackable to 5 high optional BNC of fiber port 8 or 9 port and 4 or 5 Port Personal Hubs w man up link sw Media Converters 1OMb and 100Mb series All media combinations incl fiber ST SC mm single mode The X line of configurable MiXed Media products Stackable Concentrators SNMP optional 13 Ports Mini Concentrators 7 Ports Repeaters 2 Ports Repeater Port Modules RPMs 6 types for Ethernet media COAX Transceivers 10Mb series Magnum 6K32T amp 6K32TRC Managed Switch Installation and User Guide 05 07 1 0 SPECIFICATIONS 1 1 Technical Specifications Performance Filtering Forwarding Rate Ethernet 14 880 pps Fast Ethernet 148 800 pps Gigabit Ethernet 1 488 000 pps Switching Processing Type Store and Forward with IEEE 802 3x full dup
25. 10Mb ST Fiber Port Each port has an Activity ACT LED indicating packets being received a Link LK LED indicating proper connectivity with the remote 3 device when lit and FDX HDX LED indicating full duplex mode when lit or half duplex if off 5 2 lc 6KP4 FLSTFX 2 10Mb and 2 100Mb multi mode FX ST twist lock Module The Magnum 6KP4 FLSTFX is a combo fiber module with two 1OMb two 100Mb multi mode fiber module and in combine 4 ST Fiber ports All four fiber ports are ST _ www GarrettCom com 52 Magnum 6K32T amp 6K32TRC Managed Switch Installation and User Guide 05 07 connectors and configured as 10Mb Half duplex by default for 1OMb fiber and 1OOMb Full duplex for the 100Mb fiber The 1OMb ST fiber ports allow the user to connect their legacy 1OMb network to the Magnum 6K32T amp 6K32TRC switch They also provide a convenient way for the half duplex hub to connect to the switch through 10Mb fiber ports Whereas the 100Mb ST module allow to connect the 1OOMb demand of Switch devices It supports distances according to the 1OBase FL standard 1 e 2Km distance for multi mode fiber Single mode for 10Km distance may be available as a special order Each port has an Activity ACT LED indicating packets being received a Link LK LED indicating proper connectivity with the remote device when lit and FDX HDX LED indicating full duplex mode when lit or half duplex if off 5 2 2 6KP6 RJMSC 4 10 100Mbps RJ
26. 2MT eight port Module is a combo module with copper and fiber Small Form Factor MTRJ type ports The small sizes of MTRJ connectors give an advantage of placing more fiber ports on one module The 6KP8 45 2MT is equipped with six 10 100 RJ 45 ports and two 1OOMb MTRJ fiber ports When installed in a Magnum 6K32T amp 6K32TRC Switch it supports the standard distances as mentioned on 5 2 3 and the LEDs also act similarly 5 2 lla 6KP8 45 2LC 6 k 10 100Mbps RJ 45 and 6 Port 10 100Mbps amp 2 port 100Mbps 2 100Mb single mode FX SingiMode Fib rport LC Small Form Factor 2 a The Magnum 6KP8 45SLC eight port Module is a combo module with copper and fiber Small Form Factor LC type fiber ports Th ll size of LC co tors e small s ze o connector G LINK 2 40 100 give an advantage of placing more ACTIVITY FULL HALF ports on one module The 6KP8 45 3 Q 2SLC is equipped with 6 10 100 RJ 45 ports and 2 Single mode fiber ports When installed in a Magnum 6K32T amp 6K32TRC Switch it supports the standard distances as mentioned on 5 2 4 and the LEDs also act similarly 5 2 12 GBIC SXSC Gigabit fiber 1000Mb multi mode SC Connector The Magnum GBIC SXSC is a multi mode Gigabit fiber connector equipped with SC type connectors and can be easily snapped in and out The Gigabit fiber ports are most popular as server CT to switch and switch to ls switch applications me GLK RX It supports cable ale 3 a dist
27. 48V supply must be connected to the post labeled An ON OFF manual switch is optional for DC power This can be used to cut off power connections and as a RESET for the Magnum 6K32T amp 6K32TRC Switch B4 1 UL Requirements for DC powered units Minimum ISAWG cable for connection to a Centralized DC power source Minimum 14AWG cable for connection to a earthing wiring Use only with Listed 10 A circuit breaker provided in building installation AMNA Complies with FDA radiation performance standards 21 CFR subchapter J or equivalent m Fastening torque of the lugs on the terminal block 9 inch pound max 6 Centralized DC Power Source cable securement use at least Minimum 14A WG four cable ties to secure the cable to the rac k at least 4 inches apart with the first one located within 6 inches of the terminal block B5 0 OPERATION Operation of Magnum 6K32T amp 6K32TRC Switches with the optional 4A8VDC 24VDC and 125VDC power supply is identical to that of the standard AC powered models B6 0 ORDERING INFORMATION To order the optional 48 VDC power supply factory installed add a suffix of 48VDC after the product s standard model Example Magnum 6K32R amp 6K32T amp 6K32TRC 48VDC Similarly to order the optional 24VDC or 125VDC industrial specific power supply factory installed add a suffix of 24VDC or 125VDC after the product s standard model Example Magnum 6K32T amp 6
28. 6K32T 24VDC Same as 6K32T except power input is 24VDC Magnum 6K32T 125VDC Same as 6K32T except power input is 125VDC Magnum 6K32TRC Reverse convection cooled no fans managed switch with 16 10 100 RJ 45 ports and two optional port modules which may be configured with a selection of 10 100 1000Mb fiber and copper connector types 32 ports max Magnum 6K32TRC 48VDC Same as 6K32T except power input is 48VDC Magnum 6K32TRC 24VDC Same as 6K32T except power input is 24VDC Magnum 6K32TRC 125VDC Same as 6K32T except power input is 125 VDC Configuration Options Each Magnum 6K32T amp 6K32TRC base unit has two configurable port modules slot to be configured with any one of the port modules listed below Magnum 6K32T amp 6K32TRC Port Modules 6KP8 RJ45 TP Module w eight 10 100Mbps auto negotiating RJ 45 ports 6KP4 F10ST 2 2 10Mb Fiber module w four 1OMb 2km FL ST connectors 6KP4 FXSC 2 2 100Mb Fiber module w four 1OOMb 2km FX SC connectors 6KP4 FXST 2 2 ST Fiber module w s four 1OOMb 2km FX ST connectors 6KP4 FLSTFX 2 2 ST Fiber module w two 100Mb and two 10Mb ports 2km 6KP6 RJMST 4 2 module w four RJ 45 ports and two 2km mm FX SC s 6KP6 RJMSC 4 2 module w four RJ 45 ports and two 2km mm FX ST s 6KP6 RJSSC 4 2 module w four RJ 45 ports and two 20km Sgl m FX SC s 6KP6 RJSSCL 4 2 module w four RJ 45 ports and two 40km Sgl m FX SC s 6KP8 MTRJ SFF Fiber module w eight 100Mb mm FX
29. 7 5 5 2 12 5 SXSC mode 50 125 10 GBIC 1000Mb Single 1300 9 125 95 20 85 17 10 5 LXSC10 mode i 25 GBIC 1000Mb Single 1550 9 125 4 0 21 15 37 5 17 5 LXSC25 mode GBIC 1000Mb Single 1550 9 125 4 0 21 15 17 5 ZXSC40 mode 70 GBIC 1000Mb Single 1550 9 125 3 0 23 18 20 5 ZXSC70 mode Note The use of either multi mode or single mode fiber to operate at 100Mbps speed over long distances i e in excess of approx 400 meters can be achieved only if the following factors are both applied 33 Magnum 6K32T amp 6K32TRC Managed Switch Installation and User Guide 05 07 e The 100Mb fiber segment must operate in full duplex FDX mode i e the full duplex factory default setting for 1OOMbps fiber ports must be used and e The worst case OPB of the fiber link must be greater than the fiber cable s passive Attenuation Attenuation Cable loss LED aging loss Insertion loss safety factor 3 3 Table Top or Shelf Mounting The Magnum 6K32T amp 6K32TRC Managed Switches can be easily mounted on a table top or any suitable horizontal surface They have four rubber feet to provide stability without scratching finished surfaces 3 3 1 Rack mounting for 19 RETMA racks Magnum 6K32T amp 6K32TRC s Installation of a Magnum 6K32T amp 6K32TRC Fiber Switch in a 19 rack is a simple procedure The units are 1U 1 70 high When properly installed the front mounted
30. BASE FX full duplex Long Reach 40 0 km 122K ft _ www GarrettCom com a Magnum 6K32T amp 6K32TRC Managed Switch Installation and User Guide 05 07 Maximum Standard Gigabit Ethernet Segment Lengths 1000BASE T CATSE or higher is recommended 100 m 1O000BASE SX full duplex multi mode 62 5um cable 220m 1O000BASE SX full duplex multi mode S50um cable 550m 1O00BASE LX full duplex single mode 62 5um cable 5 Km Fiber connector types supported ST type twist lock SC type snap in MTRJ type Small Form Factor SFF LC type Small Form Factor SFF GBIC modules LEDs Per Port LK Steady ON when media link is operational ACT ON with receiver port activity FDX HDX ON Full Duplex Mode OFF Half Duplex Mode 100 10 ON 100Mbps speed OFF 10 Mbps Operating Environment UL 60950 Component Parts temp ratings 130 F 55 C 6K32T UL 60950 Component Parts temp ratings 140 F 60 C 6K32TRC IEC 60068 Type Test ratings 40 to 185 F 40 to 85 C Ambient Relative Humidity 5 to 95 non condensing Altitude 200 to 13 000 ft 60 to 4000m Conformal Coating Humidity Protection option Request quote Packaging Enclosure Rugged High strength metal Suitable for stand alone or rack mounting Dimensions 1 70in H x 17 0in W x 9 0in D 4 32cm H x 43 2cm W x 22 9cm D Cooling method Fan cooled 3 7 cfm ea Management Console connector DB 9 for RS 232 null modem cable somet
31. BPM 20TX also meets the requirement for those applications where a managed Gigabit media converter is required The two Gigabit slot can be filled with copper Fiber or mix as per the application The 6K16 Series Modules provide a GBIC opening for insertion of industry standard GBICs to provide Gigabit Gb transceivers media flexibility GBIC models are available for both multi mode 550m and single mode 10 25 40 70 km fiber options and Gigabit copper as well with new models appearing often _ www GarrettCom com 63 Magnum 6K32T amp 6K32TRC Managed Switch Installation and User Guide 05 07 Each port has an Full and Half Duplex F H Activity ACT LED indicating packets being received and a Link LK LED indicating proper connectivity with the remote device when lit 5 2 12b GBIC LXSC Gigabit fiber 1000Mb multi mode SC Connector The Magnum GBIC LXSC is a single mode Gigabit fiber connector equipped with SC type connectors and can be easily snapped in and out The Gigabit fiber ports are most popular as server to switch and switch to switch applications It supports cable distances up to the IEEE 802 3z standard 1000Mbps distance limits 1 e 10 25 40 or 70Km at full duplex and depend upon the Gigabit modules used aco TX BLK RX ta 1 1000Mb Fiber SC 2 100Mb SC The two Giga port has been offered as GBPM 2OTX fiber or RJ 45 whereas the single Gigabit module comes in flavor of G 4 10 100 RJ 45 por
32. DC applications are mainly in the Industrial environment such as factory floor HVAC equipment military equipment etc B4 0 INSTALLATION This section describes the installation of the 48 VDC 24VDC and 125VDC power source leads to the 48 VDC 24VDC and 125VDC power terminal block on the Magnum 6K32T amp 6K32TRC s see figure at right In this picture the 48VDC terminal block on the Magnum 6K32T amp 6K32TRC is located on the rear of the unit and is equipped with three 3 screw down lead posts It is similar for 24VDC and 125VDC options on Magnum 6K32T amp 6K32TRC The leads are identified as negative positive and chassis ground GND Figure B4 0 48VDC Terminal Block on Magnum 6K32T amp 6K32TRC 48VDC _ www GarrettCom com 69 Magnum 6K32T amp 6K32TRC Managed Switch Installation and User Guide 05 07 The actual connection procedure is very straightforward Simply connect the leads to the Magnum unit beginning with ground Ensure that each lead is securely tightened Note The GND should be hooked up first The 6K32T amp 6K32TRC unit has a floating ground so the user may elect to Ground either or terminal to suit the customer s use Before connecting hot lines to the Terminal Block of 48VDC 24VDC or 125VDC always use a digital voltmeter to measure the output voltage of the power supply and determine the lead which is more ve potential The more ve voltage lead from 48V or
33. DC power input act as a pass through so the 48 VDC power source must be strong enough to provide power to the 6K switch and to all the 8 RJ 45 ports with PD devices connected up to 15 watts per PoE port e In the case where the 48VDC power in not internally connected and no power is coming to the PoE ports for some reason all the PoE port LEDs are ON simultaneously to indicate a trouble condition The ports will still operate properly for data traffic 5 2 10b New PoE Power Inside model PI6KP8 45RJ MDIX 10 100Mb 8 port The PoE RJ 45 ports act similar to regular RJ 45 ports except they have capability of providing power on each port to power up the PD devices per the ITEEE802 3af PoE standard Only 4 x RJ 45 10 100 ports maxm support POE Power _ www GarrettCom com 60 Magnum 6K32T amp 6K32TRC Managed Switch Installation and User Guide 05 07 Inside option in one 6K unit In this Fig the top 4 RJ45 ports are enhanced with POE option whereas as bottom 4 RJ 45 are normal MDIX ports The 4 RJ45 POE module are also available with mix n match with fiber modules Please check the ordering information Sec 1 2 for all the various PI6K PoE modules option The LEDs on 6KP8 RJ45 PoE module are slightly different compared to regular non PoE RJ 45 modules as shown in Fig 2 When the PoE port is in use the PoE LED is ON when connected properly to a 803 af compliant PD device on that port When non PoE devices are connected the
34. K32TRC 24VDC Magnum 6K32T amp 6K32TRC 125VDC www GarrettCom com 70 Magnum 6K32T amp 6K32TRC Managed Switch Installation and User Guide 05 07 B7 0 TROUBLESHOOTING Please refer to Section 6 0 for troubleshooting APPENDIX C Internal DC Dual Source Power Option C1 0 SPECIFICATIONS FOR MAGNUM 6K32T amp 6K32TRC FIBER SWITCH Power Supply Internal 48VDC Dual Source model Dual Src 48V DC Power Connector First Source A a 2nd Source B B GND Terminal for earth or ground wire connection to the hub chassis Input Two separate sources each at 36 70 VDC Power Supply Internal 24VDC Dual Source model Dual Src 24V DC Power Connector First Source A Aa 2nd Source B B GND Terminal for earth or ground wire connection to the hub chassis Input Two separate sources each at 20 36 VDC Power Supply Internal 125VDC Dual Source model Dual Src 24V DC Power Connector First Source A Aer 2nd Source B B GND Terminal for earth or ground wire connection to the hub chassis Input Two separate sources each at 88 150 VDC With the exception of the dual DC input power connections and the power supply all specifications and configuration options for the Magnum 6K32T amp 6K32TRC 4A8VDC 24VDC and 125VDC models with this Dual Source option are identical to those listed in the Magnum 6K32T amp 6K32TRC Fiber Switches Install
35. LC 100Mb fiber CT F H F H AC ACT oa LZ m Er 1 Hi Ka Tnn AC F H F H AC ACT rm LK E OLkK Fig 2 2 2 SFF Fiber Port Modules 6K8 MTRJ to the left and 6K8 MLC or SLC below 13 Magnum 6K32T amp 6K32TRC Managed Switch Installation and User Guide 05 07 In an eight port SFF fiber port module all of the fiber ports are of the same speed 1OOMb mode and connector type Models that are available with Small Form Factor SFF are multi mode MT RJ or LC type connectors and single mode LC type connectors The 100Mb fiber eight port modules for the Magnum 6K32T amp 6K32TRC normally are set factory default to operate in full duplex mode for best fiber distance and performance Using the 6K32T amp 6K32TRC s MNS software the user may select full or half duplex mode per port through the set up of the software See the Magnum 6K32T amp 6K32TRC MNS Software Manual for the flexibility to adapt to any FDX or HDX type of Fast Ethernet devices There are three LED s per fiber port The Link LK LED indicates ready for operation on that port when lit the F H LED indicates operation in full duplex mode when ON half duplex when OFF and the blinking ACT LED indicates receiving Activity on the port A fiber cable must be connected into a SFF port and the Link LK indicator for that port must be ON indicating there is a powered up device at the other end of the cable in order for a LK LED to provide valid
36. M BLNK Blank cover for one 6K32T amp 6K32TRC module slot opening in a Magnum 6K32T amp 6K32TRC chassis CONSOLE CBL Industry standard serial cable DB 9 connectors for RS 232 null modem connection sometimes called an Xmodem cable used to connect a PC ora character terminal to the Management port CONSOLE USB Console attachment cable serial to USB cable with one DB9 for the managed Switch and a USB interface for the USB connector to a PC MNS 6K License Management software Preloaded with the latest firmware license costs included with each 6K base unit Magnum 6K32T amp 6K32TRC Managed Switch Installation and User Guide 05 07 6K32T 6K32TRC PoE Modules with 48VDC Pass Through Configuration options only one A or B module slot of 6K Series switch with 48 VDC power input may be configured with a PoE Modules New P6KP8 RJ45 8 port PoE module for 6ks with 48vdc PS w eight PoE power source 10 100 auto negotiating auto cross RJ 45 ports New P6KP8 45RJ 4 4 port PoE module for 6ks with 48vdc PS w four PoE power source and four 10 100 auto negotiating auto cross RJ 45 ports New P6KP8 45MT 4 4 port PoE module for 6ks with 48vdc PS w four PoE power source and four 100 Mb 2km mm FX MTRJ connectors New P6KP8 45MLC 4 4 port PoE module for 6ks with 48vdc PS w four PoE power source and four 100 Mb 2km mm FX LC connectors New P6KP8 45SLC 4 4 port PoE module for 6ks with 48vdc PS w four PoE power
37. PoE LED is OFF Operation of Ethernet data traffic is not affected by PoE LINK and ACTIVITY LEDS are combined on the PoE modules into one LED that is marked as LINK ACT as shown in the diagram PIGKP8V 45RJ 8 Port 10 100Mb POE Copper ports Ci kaet Q 10100 G PoE C4 FULL HALF PoE LEDs Summary e For PoE devices each RJ 45 PoE port supports only 802 3af complaint devices The PoE LED is ON when the attached PD is drawing power from the port e For non PoE devices connected the PoE port will act as a normal RJ 45 port and the PoE LED is OFF No power is being sent out from the port e The PoE ports in Magnum 6K s with 48VDC power input act as a pass through so the 48 VDC power source must be strong enough to provide power to the 6K switch and to all the 8 RJ 45 ports with PD devices connected up to 15 watts per PoE port e In the case where the 48VDC power in not 6KP86KP8V 45 2MT internally connected and 6 Port 10 10Mbps and 2 port 100Mb no power 1s coming to Multi Mode Fiberport the PoE ports for some 2 reason all the PoE port LEDs are ON simultaneously to indicate a trouble condition The ports will still operate properly for Oo lt q data traffic ux mw 3 ACTIVITY 4 pULLALF _ www GarrettCom com 61 Magnum 6K32T amp 6K32TRC Managed Switch Installation and User Guide 05 07 5 2 11 6KP8 45 2MT 6 10 100Mbps RJ 45 and 2 100Mb multi mode FX MTRJ Small Form Factor The Magnum 6KP8 45
38. The 10 100 LED indicates the speed for the copper port which is 1OOMbps when the LED is ON and 10 Mb when the LED is OFF 5 2 4a 6KP6 RJ10ST 4 10 100 Mb copper port and 2 10Mbps multi mode FL ST type twist lock connector The Magnum 6KP6 RJ10OST is also a Combo module equipped with 4 dual speed copper ports and 2 multi mode 10 Mb fiber ST type connectors It provides a combination of copper and Fiber functions in one module to the 6K32T amp 6K32TRC Switches supporting four Copper and two 10Mb of ST fiber network segments The 6KP6 RJIOST when installed in a Magnum 6K32T amp 6K32TRC Switch has copper supporting the 100m distance and Fiber supporting multi mode fiber cable allow to connect the legacy network of 10Mb requirement in the network Each port has an Activity ACT LED indicating packets being received a Link LK LED indicating proper connectivity with the remote device when lit and a FDX HDX LED indicating full duplex mode when lit or half duplex when off The 10 100 LED indicates the speed for the copper port which is 10Mbps when the LED is ON and 10 Mb when the LED is OFF 5 2 5 6KP8 MTRJ 8 100Mb multi mode FX MTRJ Small Form factor Magnum 6KP8 6KP8 MT MTRJ is a multi mode fiber RJesmall form factor 8 Port 100Mbps Multi Mode Fiber port optic 8 port module equipped with a small form factor C MTRJ type connector It looks 1 3 5 7 almost like an RJ 45 port but it L L L J Ld
39. ames to propagate out to the Ethernet segments connected The cut through technique permits collision fragment frames which are a result of late collisions to be forwarded which add to the network traffic Since there is no way to filter frames with a bad CRC the entire frame must be present in order for CRC to be calculated the result of indiscriminate cut through forwarding is greater traffic congestion especially at peak activity Since collisions and bad packets are more likely when traffic is heavy the result of store and forward operation is that more bandwidth is available for good packets when the traffic load is greatest When the Magnum 6K32T amp 6K32TRC Switch detects that its free buffer queue space is low the Switch sends industry standard full duplex only PAUSE packets out to the devices sending packets to cause flow control This tells the sending devices to temporarily stop sending traffic which allows a traffic catch up to occur without dropping packets Then normal packet buffering and processing resumes _ www GarrettCom com 19 Magnum 6K32T amp 6K32TRC Managed Switch Installation and User Guide 05 07 Another feature implemented in Magnum 6K32T amp 6K32TRC Switches is a collision based flow control mechanism when operating half duplex only When the Switch detects that its free buffer queue space is low the Switch prevents more frames from entering by forcing a collision signal on all receiving ha
40. ances up to the IEEE 802 3z standard CITT 1000Mbps distance limits i e 550m at full F KE GBA duplex 1 1000Mb Fiber SC 4 10 100Mb ww GarrettCom com 62 Magnum 6K32T amp 6K32TRC Managed Switch Installation and User Guide 05 07 The GBIC transceiver has been offered in the modular slot with multiple options as per the user requirement The two Giga port has been offered as GBPM 2OTX fiber or RJ 45 whereas the single Gigabit module comes in flavor of G 2 100Mb fiber ports or G 4 10 100 RJ 45 ports as shown in the above figure The GBIC transceiver is fastened using snap in clips Insert the transceiver take care to insert it the right way up arrows on top until it clicks in space While removing the transceiver press the clips on either side of the transceiver at the same time and pull the transceiver out Each port has an Activity ACT LED indicating packets being received and a Link LK LED indicating proper connectivity with the remote device when lit 5 2 12a GBPM 20TX Two Gigabit option The Magnum 6K16 Series offered a wide selection of Gigabit speed with multiple choice of copper or Fiber or mix for the modular slot via GBPM 2OTX 2 x Giga module While up to two Gigabit modules maxm can be configured in the modular slot for GBPM 20TX The Dual Gigabit port option for the modular slot provide a wide option of choice for various Gigabit transceivers covering a long range of distance The G
41. are connected the PoE LED is OFF Operation of Ethernet data traffic is not affected by PoE LINK and ACTIVITY LEDS are combined on the PoE modules into one LED that is marked as LINK ACT as shown in the diagram 2 2 4 Six Port 4 2 Combo Modules 4 10 100 RJ 45 and 2 100Mb fiber 4 RJ 45 2 100Mb ST or SC The combo six port modules are combinations of copper and fiber media available as four 10 100 switched RJ 45 copper ports and two 100Mb switched multi mode fiber ST 16 Magnum 6K32T amp 6K32TRC Managed Switch Installation and User Guide 05 07 SC or single mode SC or Long Reach SC ports For ports numbering ports 1 3 5 7 are copper ports 2 and 6 are fiber ports 4 and 8 are not present The four RJ 45 ports operate just like the 8 port copper module with auto cross MDIX feature to eliminate the use of cross over cable and the two fiber ports operate at 1OOMbps full duplex default User mode control per port through the MNS software is also the same On Magnum 4 2 Combo modules there are four LED s for each RJ 45 port which indicate status the same as described for the 6K8 RJ45 in Section 2 2 3 above The fiber port s LEDs indicate status the same way as described for the SFF fiber modules in Section 2 2 2 above Color coding on the panel of the module shows which LEDs belong to which port The Magnum Combo six port modules are also available with 4 MTRJ 100Mb mm SFF fiber and 2 10Mb fiber
42. are user options for an UP LINK Switch resides inside the unit on the 6K8 RJ45 modular port Optional Half Full duplex mode and 10 or 1OOMbps selection for the switched ports must be configured through MNS 6K software per unit as per the requirement The internal functions of both are described below Filtering and Forwarding Each time a packet arrives on one of the switched ports the decision is taken to either filter or to forward the packet Packets whose source and destination addresses are on the same port segment will be filtered constraining them to that one port and relieving the rest of the network from having to process them A packet whose destination address is on another port segment will be forwarded to the appropriate port and will not be sent to the other ports where it is not needed Traffic needed for maintaining the operation of the network such as occasional multi cast packets are being forwarded to all ports The Magnum 6K32T amp 6K32TRC Switches operate in the store and forward switching mode which eliminates bad packets and enables peak performance to be achieved when there is heavy traffic on the network Address Learning All Magnum 6K32T amp 6K32TRC units have address table capacities of 4K node addresses suitable for use in larger networks They are self learning so as nodes are added removed or moved from one segment to another the 6K32T amp 6K32TRC Switch automatically keeps up with node location
43. aterial Authorization RMA Procedure cccccceeeees 66 6 4 Shipping and Packaging Information cccccccccccsssssssseeeseeeeeeeeeees 67 APPENDIX A WARRANTY INFORMATION cssssssscccccccesssssscoes 67 APPENDIX B INTERNAL DC POWER SUPPLY OPTIONG 68 APPENDIX C INTERNAL DC DUAL SOURCE POWER OPTION 71 Revisions Rev C 05 07 SFP fiber info added and Typo error updated on Temp Rev C 10 06 Included 6K32TRC and PoE Modules Rev B 12 05 Updated Gigabit options Rev A 05 05 Minor updates Auto Cross MDIX Rev A 02 05 Minor updates and tweak on LC connector diagram Rev A 08 04 This revision is the initial release of the 6K32T manual 1V Magnum 6K32T amp 6K32TRC Managed Switch Installation and User Guide 05 07 The Magnum Line INDUSTRIAL NETWORKING PRODUCTS DESIG NED AND MANUFACTURED IN THE USA OVERVIEW GarrettCom Inc offers the premium quality Magnum line of INDUSTRIAL conectivity products with industry standard functionality and built in fiber configurability Magnum products are designed for use in demanding Industrial Grade Carrier Class POWER UTILITY and OEM applications where reliability is a primary consideration 6K Series Managed Field Switches Gigabit 100 and 10 Mbps fiber and copper ports mix and match Features SFF fiber and DC power in 1U units DX Series Serial Device Routers Ethernet and Serial 4K Series Switches 100 and 10 Mbps copper ports
44. ation and User Guide including Appendix B Internal DC Power Supply Option C2 0 MAGNUM 6K32T amp 6K32TRC amp 6K32 with 48VDC 24VDC and 125VDC Dual Source option The 6K32T amp 6K32TRC amp 6K32 Switch models with the internal 48VDC 24VDC and 125VDC Dual Source power supply are designed for installations where a battery plant is the power source and where two separate power sources are utilized in order to increase operational uptime and to simplify maintenance The functionality of the Magnum 6K32T amp 6K32TRC Switch 48VDC 24VDC and 125VDC Dual Source Option units is identical to the standard AC powered models Refer to the main sections of this Installation and User Guide for a detailed description of the Magnum 6K32T amp 6K32TRC Switches At o A B Bt GND Magnum 6K32T amp 6K32TRC Managed Switch Installation and User Guide 05 07 C3 0 DUAL SOURCE OPTION THEORY OF OPERATION The Dual Source DC power option is designed using diodes inside of the chassis on each DC power input line A diode is placed in each of the four input lines behind the four external power connection terminals so that power from an external source can only flow into the unit This allows the unit to operate whenever DC power is correctly applied to either or both of the two inputs C4 0 FEATURES AND BENEFITS OF THE DUAL SOURCE DESIGN a The Switch unit can receive power from either input A or B The hub will no
45. bility and AC DC option will be an additional feature to take care of temperature and power option issue _ www GarrettCom com a 25 Magnum 6K32T amp 6K32TRC Managed Switch Installation and User Guide 05 07 Equipped with IGMP L2 mode enhanced features allow the Magnum 6K32TRC to meet the fastest growing application of video monitoring or video surveillance demand of industry and provide an economical and effective solution to meet that expectation Gigabit Connector y T Encoder Mieg Encoder Tew Encoder West amz j Fir Te E n d r Encoder Figure 4 A multicast traffic through a 6K32TRC Switches using IGMP L2 mode feature with Gigabit redundancy 26 Magnum 6K32T amp 6K32TRC Managed Switch Installation and User Guide 05 07 3 0 Installation Before installing the equipment it is necessary to take the following precautions 1 If the equipment is mounted in an enclosed or multiple rack assembly the environmental temperature around the equipment must be less than or equal to 55C FOR 6K32T and 60C for 6K32TRC 2 If the equipment is mounted in an enclosed or multiple rack assembly adequate airflow must be maintained for proper and safe operation 3 If the equipment is mounted in an enclosed or multiple rack system placement of the equipment must not load unevenly or overload the rack system 4 If the equipment is mounted in an enclosed or multiple rack assembly verify the equipment s
46. ceplate screws out from TELL ie x Pa r 41 LERH i i i EEJ wees STEEN ii LPR i m ss ka aD Ti ee gt lt J A i pr E arr ry 1 J i 7 r ETET the inside front of the chassis cover by loosening the 4 screws and bracket while holding it down firmly Figure 3 5 3a Top View 6 retaining screws shown by arrows Step 3 Remove 6KPM Card Carefully and gently pull out the daughter board from the latching connectors using both hands gripping the board near the latch up 43 Magnum 6K32T amp 6K32TRC Managed Switch Installation and User Guide 05 07 connectors as shown in Fig 3 5 3b If the now empty slot is to remain unused be sure to install a 6KPM BLNK face plate cover Figure 3 5 3b Removing a 6KPM Card Follow the step 8 to complete the process successfully NOTE 1 If the modular slot has not being used and moved to other unit the empty slot must be covered with Blank cover to maintain proper air inflow inside the unit and keep off from dust and other unavoidable substance otherwise can cause a failure in the Switch 2 If the PM module in the modular slot is not being installed properly or loose in connection the MNS 6K management software will not boot up properly and a error will generate as failed to read register device type offset 0x 1600 on slot A or B or C or D whichever the slot has been used 3 Always boot up the Switch after any new module installation on
47. cts 1 There is four terminal block 1 2 3 4 provided next to AC DC power supply 2 The top two pins 1 2 are software operated 3 The bottom two pins 3 4 are hardware operated 4 By default it is NC normally closed 5 The software operation needs to be enabled and set to get the Alarm traps For detailed information about the Software Alarm and software control of SNMP alarm traps please reference the Magnum MNS 6K Software User Manual Chapter 19th 3 5 6K32T amp 6K32TRC Port Module 6KPM Installation The Magnum 6K32T amp 6K32TRC Switches are normally received from the factory with 24 ports fixed and one required 6KPM module installed There may be situations where 6KPM cards need to be added or replaced In cases where a 6PM module needs to be added in the modular slot the faceplate for an available front mounted slot must be removed The following procedure describes this operation 3 5 1 Preparation for Installing and Removing 6KPMs STOP Be sure the power cord and connections for all powers single or dual is unplugged from the chassis before attempting to remove and or replace any PM cards Failure to do so may result in damage to the unit and will void the warranty Caution Avoid Static Discharge Opening of the 6K32TRC chassis can only be performed by trained service persons The port modules like most electronic equipment are sensitive to static discharge Use proper ESD measures when handling port module
48. d Benefits cecceecccccecccceeeceeeeeeceeeeeeeeeeeeeeeeeeeeeeeeeeeenees 21 2 4 Applications cece iscsnsascasesnascagsqenidncgadagaxsaaansasha sncessesoquanenbiantannnanneotionis 22 3 0 INSTALLA TTON seaun 27 3 1 Locating Magnum 6K32T Switches cccccccccceceeeeeeeeeeeeeeeeeeeeees 27 3 2 Connecting Ethernet Media c cccceceeeeeccccsseeeesssssseeeeeeeeeees 28 3 2 1 Connecting Fiber Optic ST type twist lock ee 28 22 Connecting Fiber Optic SC type Snap In ee 29 3 2 Connecting Single Mode Fiber Optic seeesssssssssssssseeerreereee 29 3 2 4 Connecting Twisted Pair RJ 45 CAT3 CATS cccccccsseceeeeeeceeees 29 3 2 5 Connecting Twisted Pair CAT Se or better cccccccseseceeeeeeeeeees 30 3 2 6 Gigabit SFP Small Form factor Pluggable Transceivers 30 3 2 7 Power Budget Calculations 6K32T amp 6K32TRC PM s ccccsseeeeeeees 32 3 3 Table Top or Shelf Mounting ccecesesssesesseeeeeeceeeeeeeeeeaeeaeeeenees 34 3 3 1 Rack mounting for 19 RETMA 6K32T amp 6K32TRC s 34 3 3 2 Rack mounting Reverse version of the Magnum 6K32T s 35 3 4 Powering the Magnum 6K32T amp 6K32TRC Managed Switch 36 3 4 1 Alarm Contacts for monitoring internal power Traps 0 36 33 6K32T amp 6K32TRC Port Module 6KPM Installation 37 3 5 1 Preparation for Installing and Removing 6KPMsS ccccceees 37 3 5
49. d in a Magnum 6K32T amp 6K32TRC Switch it supports the standard Nn distances as per mentioned on 5 2 8 and the LEDs also acts similarly as mentioned above 5 2 9 6KP8 RJ45 Twisted Pair 6KP8 RJ45 10 100Mb 8 Port 8 Port 10 100Mb Copper ports The 6KP8 RJ45 module supports Ethernet twisted pair segments of any standard length It is equipped with an eight port RJ 45 connector and offers 10 100 full half duplex auto negotiating capability on each port The RJ 45 connector is shielded to minimize emissions and will allow both unshielded twisted pair UTP and shielded twisted pair STP cable connections The 6KP8 RJ45 module is equipped with a Media Dependent Auto Crossover MDI X switch which controls all _ www GarrettCom com a 58 Magnum 6K32T amp 6K32TRC Managed Switch Installation and User Guide 05 07 ports for cascaded connection This feature eliminates the need for a special twisted pair crossover cable when connecting to a hub or another switch Each port has an Activity ACT LED indicating packets being received a Link LK LED that indicates proper connectivity with the remote device when lit a FDX HDX LED to indicate full duplex mode when lit or half duplex when off and a 10 100 LED indicating 100Mb when lit or 10 Mbps when off Important Note The 10 100 RJ 45 ports are supported with Auto negotiation and Auto crossover MDIX which allow the RJ 45 ports to automatically Link
50. de the Magnum 6K32T amp 6K32TRC Fig 3 5 22 Top View 6KPM Module installed inside a 6K32T amp 6K32TRC Switch Step 7 Once the installation of granddaughter and daughter modules is done properly the front panel screen plates come along with the 6K module need to be properly placed on the front of the chassis cover to complete the installation process 42 Magnum 6K32T amp 6K32TRC Managed Switch Installation and User Guide 05 07 Step 8 Once the 6KPM cards have been installed the chassis top cover should be replaced by matching at the two front corners properly and slide in until it reaches the rear end and fit properly to match the holes Make sure the chassis cover is aligned properly before securing the enclosure Place the front panel part at the end by sliding in to the front side and secure it with 12 screws as being mentioned earlier 3 5 3 Removing 6KPM Cards To properly remove a 6KPM card from the 6K32T amp 6K32TRC Managed Switch follow the 3 steps below Step 1 Remove chassis cover See procedures in Section 3 5 1 above Caution Be sure the power cord is unplugged Step 2 Remove retaining screws placed on top for the 6KPM and Face Plate On the top of the daughter module there are six retaining screws for each 6KPM card These screws are used to secure a 6KPM card in position see Figure 3 5 3a Remove the three standoffs holding the Granddaughter board with the chassis The screen fa
51. dled efficiently by this managed switch and will play an effective role in providing modularity to the solution The growing demand of security and Ease of use are the other adding features of this managed switch The switch allows the users to secure their network through port security Radius X Tacacs and Snmpv3 and provide an effective solution of ease of use through Secure Web based management and scripts feature to manage the 6K32T switch remotely The 6K32T loaded with robust MNS 6K firmware is specially designed to meet the future demand of Ethernet requirement with cost effective secure solutions The Magnum 6K32T is also available in a Reverse model option where the LEDs are on the front and the available ports along with the power supply area found on the rear side This configuration is mostly used for carrier class market The modules which may be configured and used in the modular slots of the Magnum 6K32T are described here www GarrettCom com 12 Magnum 6K32T amp 6K32TRC Managed Switch Installation and User Guide 05 07 The Magnum 6K32T is preloaded with robust and intuitive MNS 6K Managed Network Software to handle industry standard IEEE 802 1p QOS prioritization and non blocking wire speed on all ports It provides high performance switching services for both smooth streaming and bursty data traffic For redundant LANs it offers S ring RS Ring Link Loss Learn STP and RSTP Security feature
52. dth rack mount 6K switch with 125VDC power input www GarrettCom com Magnum 6K32T amp 6K32TRC Managed Switch Installation and User Guide 05 07 New PI6KP8 45RJ 4 4 port PoE module for 6ks with 48vdc PS w four PoE power source and four 10 100 auto negotiating auto cross RJ 45 ports New PI6KP8 45MT 4 4 port PoE module for 6ks with 48vdc PS w four PoE power source and four 100 Mb 2km mm FX MTRJ connectors New PI6KP8 45MLC 4 4 port PoE module for 6ks with 48vdc PS w four PoE power source and four 100 Mb 2km mm FX LC connectors New PI6KP8 45SLC 4 4 port PoE module for 6ks with 48vdc PS w four PoE power source and four 100 Mb 15km sm FX LC connectors New PI6KP8 45 2MT 6 2 port PoE module for 6ks with 48vdc PS w four PoE power source and two normal RJ 45 10 100 ports twol00 Mb 2km mm FX MTRJ connectors New PI6KP8 452SLC 6 2 port PoE module for 6ks with 48vdc PS w four PoE power source and four 100 Mb 15km Sm FX LC connectors New PI6KP6 RJMST 4 2 port PoE module for 6ks with 48vdc PS w four PoE power source and two 100 Mb 2km mm FX ST connectors New PI6KP6 RJMSC 4 2 port PoE module for 6ks with 48vdc PS w four PoE power source and two 100 Mb 2km mm FX SC connectors New PI6KP6 RJSSC 4 2 port PoE module for 6ks with 48vdc PS w four PoE power source and two 100 Mb 20km sm FX SC connectors New PI6KP6 RJSSCL 4 2 port PoE module for 6ks with 48vdc PS w four PoE power source and
53. ectors 1 e using 6K MSC or 6K SSC single mode etc When connecting fiber media to SC connectors simply snap the two square male connectors into the SC female jacks of the 6KPM until they click and are secure 3 2 3 Connecting Single Mode Fiber Optic When using single mode fiber cable be sure to use single mode fiber port connectors Single mode fiber cable has a smaller diameter than multi mode fiber cable 9 125 microns for single mode 50 125 or 62 5 125 microns for multi mode where xx xx are the diameters of the core and the core plus the cladding respectively Single mode fiber allows full bandwidth at longer distances and may be used to connect 10 Mb nodes up to 10 Km apart or 18Km with the 6K SSC The same procedure for multi mode fiber applies to single mode fiber connectors Follow the steps listed in Section 3 2 2 above 3 2 4 Connecting Twisted Pair RJ 45 CAT3 CAT5 Unshielded or Shielded The RJ 45 ports of the Magnum 6K32T amp 6K32TRC can be connected to the following two media types 1OOBASE TX and 1OBASE T CAT 5 cables should be used when making 1OOBASE TX connections When the ports are used as L OBASE T ports CAT 3 may be used In either case the maximum distance for unshielded twisted pair cabling is 100 meters 328 ft Media IEEE Standard Connector Twisted Pair CAT 3 4 5 10BASE T RJ 45 Twisted Pair CAT 5 100BASE TX RJ 45 NOTE It is recommended that high quality CAT 5 cables which work for both 10 Mb
54. ed please use the original shipping container if possible Refer to Section 6 Troubleshooting for specific return procedures Magnum 6K32T amp 6K32TRC Managed Switch Installation and User Guide 05 07 2 2 Product Description Magnum 6K32TRC Managed Switch The IEC61850 complied and attributed with green environmentally friendly Magnum 6K32TRC Managed Switch is specially designed with a convection cooled thermal design techniques to minimize heat generation to provide an efficient highly reliable and secured Ethernet solution for heavy duty Industry Power sub stations and temp uncontrolled outdoor applications Specially designed and enclosed in a Reverse aluminum case the 6K32TRC proudly offered with modularity port density up to 32 ports max and security in a 1U rack mount package Being a sibling of the successful 6K managed switch family the Magnum 6K32TRC supports modularity in the last two slots to configure with any of the various Figure 2 2 1a A typical 6K32TRC front view 16 RJ 45 ports Fixed 2 Modular slot with 8 Port fiber on C and Dual Giga module on D slot 6KP modules offered The Magnum 6K32TRC provides effective and economical Ethernet solutions with 16 10 100 RJ 45 ports fixed and two modular configuration slots The two modular configurable slots of the Magnum 6K32T offer the flexibility to configure up to sixteen 100Mb RJ 45 and 16 fiber ports or a maximum of four Gigabit 1000Mb opti
55. en installing or operating the unit refer back to the Installation Section of the applicable chapter of this manual Also check to make sure that the various components of the network are interoperable 2 Check the cables and connectors to ensure that they have been properly connected and the cables wires have not been crimped or in some way impaired during installation About 90 of network downtime can be attributed to wiring and connector problems 3 Make sure that an AC power cord is properly attached to each Magnum 6K32T amp 6K32TRC Switch unit Be certain that each AC power cord is plugged into a functioning electrical outlet Use the PWR LEDs to verify each unit is receiving power 4 If the problem is isolated to a network device other than the Magnum 6K32T amp 6K32TRC Switch product it is recommended that the problem device be replaced with a known good device Verify whether or not the problem is corrected If not go to Step 5 below If the problem is corrected the Magnum 6K32T amp 6K32TRC Switch and its associated cables are functioning properly 5 Always check your Switch configuration specially Auto negotiation behavior with other connected device to have proper setup tested ww GarrettCom com 65 Magnum 6K32T amp 6K32TRC Managed Switch Installation and User Guide 05 07 Ds If the problem continues after completing Step 4 above contact your supplier of the Magnum 6K32T amp 6K32TRC Switch unit or if
56. ernal power supply nor will it blow the fuse in the internal power supply The manual power On Off Switch optional is used for powering the unit on and off when it is placed into or taken out of service B3 0 APPLICATIONS FOR DC POWERED SWITCHES Magnum 6K32T amp 6K32TRC Fiber Switches are easily installed in a variety of applications where 48 VDC 24VDC and 125VDC power is used as the primary power source The 48VDC 24VDC and 125VDC power configuration provides an Ethernet networking solution utilizing a special power supply in a Managed Switch The 48VDC solution is particularly useful in the telecommunication industry where it is common for facilities to operate on 48 VDC power Such companies include regular and wireless telephone service providers Internet Service Providers ISPs and other communication companies In addition many high availability equipment services such as broadcasters publishers newspaper operations brokerage firms and other facilities often use a battery backup system to maintain operations in the event of a power failure It is also frequently used for computer system backup management and operations monitoring equipment The 24VDC and 125VDC solution are particularly useful in the Industrial environment where it is common facilities to operate on 24VDC or 125VDC power The 125VDC solution is mainly used in power utilities such as electrical substations electrical generating plants etc The 24V
57. erson Name of your company institution Your shipping address www GarrettCom com 66 Magnum 6K32T amp 6K32TRC Managed Switch Installation and User Guide 05 07 Product name Serial Number or Invoice Number Packing List Number or Sales Order Number Date of installation Failure symptoms including a full description of the problem GarrettCom will carefully test and evaluate all returned products will repair products that are under warranty at no charge and will return the warranty repaired units to the sender with shipping charges prepaid see Warranty Information Appendix A for complete details However if the problem or condition causing the return cannot be duplicated by GarrettCom the unit will be returned as No Problem Found GarrettCom reserves the right to charge for the testing of non defective units under warranty Testing and repair of product that is not under warranty will result in a customer user charge 6 4 Shipping and Packaging Information Should you need to ship the unit back to GarrettCom please follow these instructions 1 Package the unit carefully It is recommended that you use the original container if available Units should be wrapped in a bubble wrap plastic sheet or bag for shipping protection You may retain all connectors and this Installation Guide CAUTION Do not pack the unit in Styrofoam popcorn type packing material This material may cause electro static shock da
58. es First Remove the front panel screws total 12 as shown in the fig 3 5 1a Once these are removed the front panel can be easily pulled out to the front The top cover can be easily pulled off to the front from the chassis base as shown in the Fig 3 4 1b When the chassis top cover has been removed the interior of the unit is exposed Figure 3 5 la Removing front panel after the screws being removed 38 Magnum 6K32T amp 6K32TRC Managed Switch Installation and User Guide 05 07 Fig 3 5 1b Pulling out the top coved from the chassis base Caution Be careful not to disturb the power supply Looking down into the Magnum 6K32T amp 6K32TRC unit notice that there are individual PM installation spaces and female latch white connectors provided on the far right side of main board along with four stand off s for 6KPM card position See Figure 3 5 1 Figure 3 5 1c Magnum 6K32T amp 6K32TRC modular slot side front right side without chassis cover Step 3 Remove front panel face plate retaining screws There are one PM slot located on the front right side of the chassis cover Looking into the vertical placed Chassis cover of the unit there are one bracket with retaining screws 256 flat head which hold _ www GarrettCom com a 39 Magnum 6K32T amp 6K32TRC Managed Switch Installation and User Guide 05 07 the PM Face plate card slot securely These six screws shown in the picture below are
59. for the LAN structure The secured management features offer a multiple options to provide a secure Network solution Example 1 Magnum 6K32T Switch for a VLAN application Equipped with lots of advanced management features the Magnum 6K32T Managed switch is able to handle a VLAN application and provide security and performance in an Ethernet network center A secure VLAN enabled network is simply an administratively configured broadcast domain The network administrator determines which ports and nodes are in which broadcast domains by setting membership profiles _ www GarrettCom com a 22 Magnum 6K32T amp 6K32TRC Managed Switch Installation and User Guide 05 07 for each of them The Magnum 6K32T s VLAN capability can be configured in two types of virtual LANs Port based VLANs and Tag based VLANs In an office environment where departments such as Finance Engineering R amp D and Marketing need to each keep a secure LAN the 6K32T s VLAN feature will prevent traffic cross over among traffic domains and thus keep sensitive data and information controlled The Managed Magnum 6K32T equipped with VLAN capability is ideal for any application where a secure VLAN to multiple departments is needed The modularity of the 6K32T Managed Switch makes it an attractive choice for use in applications with LAN connections to an organization s multiple site offices The different offices can be easily connected together with the Fiber ports sup
60. gabit ports copper or Fiber maximum The Gigabit port option for the modular slot comes in a couple of different configurations The two Gigabit port modules have been offered as GBPM 2OTX fiber or RJ 45 whereas the single Gigabit module comes in flavors of G 4 10 100 RJ 45 ports or G 2 100Mb fiber ports as shown below in the figure pe TX BLK RX bo fn TX RX TX 1 1000Mb Fiber SC 2 100Mb SC 1 1000Mb Fiber SC 4 10 100Mb The 6K32T amp 6K32TRC modules provide a GBIC opening for insertion of industry standard GBICs to provide Gigabit Gb media flexibility GBIC models are available for both multi mode 550m and single mode 10 25 40 70 km fiber options and for Gigabit copper as well with new models appearing often The 1000Mb Gigabit fiber port modules on the Magnum 6K32T amp 6K32TRC are normally set factory default to operate at AUTO mode for best fiber distance and performance The 1000Mbps SC fiber optic module on the Gigabit SX and Gigabit LX transceivers are compatible with the IEEE 802 3z Gigabit standards There are two LEDs mounted on each Gigabit port module The Gigabit fiber port is by default configured to AUTO mode and can be fixed at 1OOOMbps speed full duplex mode at any time The Gigabit fiber port has LEDs that indicate LK Link status and ACT receiving activity on that port when lit For Dual Gigabit modules option please check page 60 for details info _ www GarrettCom com a 18
61. get Section 4 5 Each port has an Activity ACT LED indicating packets being received a Link LK LED that indicates proper connectivity with the remote device when lit and a FDX HDX LED to indicate full duplex mode when lit or half duplex when off The 10 100 LED indicates 100Mbps speed when lit and 10Mbps speed when off To distinguish the single mode 6 K6 RJSSC from the multi mode 6K6 RJMSC the label Sel M is at the top of the faceplate of the 6K6 RJSSC 5 2 4 6KP6 RJSSCL 4 10 100 Mb copper port and 2 100Mbps single mode FX SC type snap in connector The Magnum 6KP6 RJSSC is also a Combo module equipped with 4 dual speed copper ports and 2 Single mode Long Reach SC type connectors It provides a combination of copper and Fiber functions in one module to the 6K32T amp 6K32TRC Switches supporting four Copper and two single mode Long Reach fiber network segments The 6KP6 RJSSC when installed in a Magnum 6K32T amp 6K32TRC Switch has copper supporting the 100m distance and Fiber supporting single mode fiber cable lengths of as much as 40 Km see Power Budget Section 4 5 WWW GarrettCom com 3 3 54 Magnum 6K32T amp 6K32TRC Managed Switch Installation and User Guide 05 07 Each port has an Activity ACT LED indicating packets being received a Link LK LED indicating proper connectivity with the remote device when lit and a FDX HDX LED indicating full duplex mode when lit or half duplex when off
62. half duplex The 10Mb Multi mode ST Fiber connector supports the standard fiber optic distance limit of 2Km at Full and Half duplex both The functionality of this 100BASE FX multi mode 4 port module is essentially the same as the ST and SC types It has the same LEDs per port indicating port activity ACT Link LK and FDX or HDX operation 56 Magnum 6K32T amp 6K32TRC Managed Switch Installation and User Guide 05 07 5 2 6 6KP8 45MT 4 10 100Mbps RJ 45 and 4 100Mb multi mode FX MTRJ Small Form Factor The Magnum 6KP8 45MT 6KP8 45MT 4 Port 10 100Mbps amp 4 port 100Mbps Multi Mode AD Module is a combo module with copper and fiber Small Form Factor MTRJ type ports The small size of MTRJ connectors give an advantage of placing more ports on one module The 6KP8 45MT is equipped with 4 10 100 RJ 45 ports and 4 MTRJ fiber 2 4 6 8 A ports C1 LINK 2 10 100 When installed in a Magnum 6K32T ACTIVITY Q FULL HALF amp 6K32TRC Switch it supports the standard distances as mentioned on 5 2 3 and the LEDs also act similarly 5 2 7 6KP8 MLC 8 ports 100Mbps multi mode LC connector Small Form Factor 8Port 100Mbps MLC Ports Magnum 6KP8 MLC is a eight port multi mode fiber LC connector small form factor used primarily in 100Mbps fiber to the F H F H aor ACT an oO F H T 4 6 ACT ACT EH j a is a i a ACT _ u F H m LKE o kE kot desktop links When installed in a Magnum
63. imes called an X modem cable Power Supply Internal AC Power Connector EC type male recessed at rear of chassis with adjacent manual ON OFF switch optional if no Alarms Cont Input Voltage 100 to 240 VAC auto ranging Input Frequency 47 to 63 Hz auto ranging Power Consumption 45 watts max with fiber module 30 watts for a fully loaded copper only model Fuse required for replacement 1 Amps DC Power Supply Options 48VDC Power Input Voltage 36 to 70 VDC _ www GarrettCom com 3 Magnum 6K32T amp 6K32TRC Managed Switch Installation and User Guide 05 07 Fuse Required 2Amps 24VDC Power Input Voltage 20 to 40VDC Fuse Required 3Amps 125VDC Power and 100VDC Input Voltage 88 to 300VDC Fuse Required 1Amps Std Terminal Block GND Power Consumption same as for AC models see above Warning All the fuse replacment must be replaced with same value For Optional DC internal power supplies at 48VDC 24VDC and 125VDC including Dual Source options for continuity of operation when either of the DC input sources are interrupted see Appendices B and C Cooling Method 6K32T 6K32TR Reverse Fan cooled 3 fans inside 6K32TRC Convection cooled No fans Static Thermal design techniques Relay Alarm Contact Optional The Alarm Contact option is offered as a configuration option The alarms can be initiated through two normally closed Form C contacts one loss of power alarm a
64. indications of operating conditions on that port 2 2 3 Eight Port Copper Module 6K8 RJ45 MDIX The 6K Series s 8 port Copper port module model 6K8 RJ45 provides eight 10 100Mb switched RJ 45 ports The 10 100Mb switched ports normally as a default setting are independently N way auto negotiating and auto crossover MDIX for operation at 10 or 1OOMb speed in full or half duplex mode i e each independently selects a mode and speed to match the device at the other end of the twisted pair cable See Section 4 3 for auto negotiation and MDIX details The auto crossover feature will automatically determine the other side of connection to make the connection and eliminate the need of cross over cable www GarrettCom com NN 14 Magnum 6K32T amp 6K32TRC Managed Switch Installation and User Guide 05 07 On the model 6K8 RJ45 module there are four LEDs for each port two in the connector and two separate The LK Link LED indicates ready for operation on that port when lit The blinking ACT Activity LED indicates receiving Activity on that port when lit The 10 100 LED indicates operation at 100Mb speed when ON and at 10 Mb speed when OFF when auto negotiation is not disabled 10 T The FDX HDX LED is ON to Lies 20 gt O 04T Opa Fel lt indicate full duplex operation and OFF to indicate half duplex mode A twisted pair cable must be connected into an RJ 45 port and the Link LK indicato
65. ing RSTP Link Loss Learn and various security features are easily qualified for the application The 48VDC input power option with Dual Source is especially useful in telecom central offices The Magnum 6K32T with two Gigabit ports in the modular slot allows it to connect into a Gigabit mesh structure with an RSTP and S Ring combination used in a no single point of failure self healing LAN topology along with a ring of multiple 6K25s at the edge to allow the system to efficiently recover from a fault in the network The industry standard Rapid Spanning Tree Protocol 802 1d is used in the top eight switches see diagram below to perform GB mesh fault recovery whereas the bottom ring setup has been configured with S Ring and Link Loss Learn for faster recovery in a big ring A redundant LAN setup not only provides a reliable recovery solution from network faults but also improves operating up time to simplify maintenance save money and recover valuable time In a critical application where secure data has been stored in a data mining storage facility a redundant network provides a more secure solution The figure below has Magnum 6K32T s and 6K25 s connected over the gigabit mesh structure for a high bandwidth secure redundant LAN setup www GarrettCom com NN 24 Magnum 6K32T amp 6K32TRC Managed Switch Installation and User Guide 05 07 Switch 4 Eee m mgg A aaa a a FTA server Sh a a a bal Switches above
66. ion and User Guide 05 07 PoE LED is ON when connected properly to a 803 af compliant PD device on that port When non PoE devices are connected the PoE LED is OFF Operation of Ethernet data traffic is not affected by PoE LINK and ACTIVITY LEDS are combined on the PoE modules into one LED that is marked as LINK ACT as shown in the diagram 2 2 3b New PoE Power Pass through model P6KP8 RJ45 MDIX 10 100Mb 8 port The PoE Power pass through RJ 45 ports act similar to regular RJ 45 ports except they have capability of providing power on each port to power up the PD devices per the IEEE802 3af PoE standard The Power Pass through PoE modules are totally dependent upon the powerful 48VDC input power supply to support more RJ 45 10 100 ports Each port requires atleast 15watts to power up the PoE PD devices Maxm one PoE modules can be configured in the A B or C slot of any 6K s with 48vdc power input The PoE modules are also available with mix n match with fiber modules Please check the ordering information Sec 1 2 for all the various P6K PoE modules option P6 amp KPB R45 The LEDs B Pert 10M00Mb Copper with on 6KP8 RJ45 PoE POE ports module are slightly different compared to regular non PoE RJ 45 modules as PT ine shown in Fig 2 i When the PoE port CD klact D 10 106 is in use the PoE PoE FULLJHALF LED is ON when D connected properly to a 803 af compliant PD device on that port When non PoE devices
67. ion can be disabled if fixed the port at 10 or 1OOMb through software The Managed Magnum 6K32T amp 6K32TRC Fast Ethernet copper ports can be set for either fixed 100Mb speed or N way auto negotiation per the IEEE802 3u standard The selection is made via 6K MNS software The factory default setting is for auto negotiation At 100Mb fixed speed the user may select half or full duplex mode by 6K MNS Software for each RJ 45 port separately For detail information see Section 7 Port Setup of Magnum 6K32T amp 6K32TRC Software user guide MNS 6K One frequently used application for the Managed 6K32T amp 6K32TRC Switch copper ports is to connect one of them using a fiber media converter to another Switch in the network backbone or to some other remote 100Mb device In this case it is desirable to operate the fiber link at 1OOMb speed and at either half or full duplex mode depending on the capabilities of the _ www GarrettCom com 47 Magnum 6K32T amp 6K32TRC Managed Switch Installation and User Guide 05 07 remote device Standard commercially available Fast Ethernet media converters mostly do not support auto negotiation properly and require that the switched port to which they are connected be at 1OOMb fixed speed Attachment to 10 100 auto negotiation ports typically will not work properly The 6K32T amp 6K32TRC Switch s RJ 45 ports handle this situation by configuring the ports as per desire through MNS software port
68. iver to support LOBASE FX network segments When installed in a Magnum 6K32T amp 6K32TRC Managed Switch the copper port supports the standard distance 100m on each port and the fiber port supports fiber optic cable distances up the IEEE standard 10Mbps distance limits 1 e typically 2km at full duplex and half duplex Each port has an Activity ACT LED indicating packets being received a Link LK LED that indicates proper connectivity with the remote device when lit and FDX HDX LED to indicate full duplex mode when lit or half duplex when off The 10 100 LED indicates the speed if the LED is ON 100Mbps if it is OFF 1OMbps 51 Magnum 6K32T amp 6K32TRC Managed Switch Installation and User Guide 05 07 5 2 1b 6KP4 F10ST 4 10Mb multi mode FX ST twist lock Module The Magnum 6KP4 F10ST 6KP4 RJLOMST is a LOMb multi mode 4 Port 10Mb ST Fiber Port fiber module with 4 ST Fiber ports All four fiber ports are ST connectors and configured as 10Mb 3 Half duplex by default The 1OMb ST fiber ports 2 TX GLK RX allow the user to connect their legacy 10Mb network G FULL HALF to the Magnum 6K32T amp 6K32TRC switch They also provide a convenient way for the half duplex hub to connect to the switch through 10Mb fiber ports It supports distances according to the 10Base FL standard 1 e 2Km distance for multi mode fiber Single mode for 10Km distance may be available as a special order 6KP4 RJIOMST 4 Port
69. lex flow control non blocking Data Rate 1OMbps 100Mbps and 1000Mbps Address Table Capacity 4K node self learning with address aging Packet buffer size 240KB for 10 100 and 120KB for 1OOOMb Latency 5 us packet time 100 to 1OOMbps 15 us packet time 10 to 10 Mbps and 10 to 1OOMbps Throughput with 16 10 100 and 4 Glink max 8 33M pps Transmit Back plane 2 66Gb s per slot Network Standards and Compliance Ethernet V1 0 V2 0 IEEE 802 3 1OBASE T IEEE 802 3u 100Base TX 1OOBASE FX IEEE 802 3z 1OOOBASE X Ethernet Auto negotiation IEEE 802 3ab 1OOOBASE X Ethernet IEEE 802 1p Priority protocol IEEE 802 1d Spanning tree protocol IEEE 802 1w Rapid Spanning tree protocol IEEE 802 1q VLAN Tagging IEEE 802 3x Flow Control IEEE 802 3ad Link Aggregation Trunking IEEE 802 1x Port based Network access control Maximum 10 Mbps Ethernet Segment Lengths Unshielded twisted pair 100 m 328 ft Shielded twisted pair 150 m 492 ft 1OBASE FL multi mode fiber optic 2 km 6 562 ft 1OBASE FL single mode fiber optic 10 km 32 810 ft Maximum Standard Fast Ethernet Segment Lengths 1OBASE T CAT 3 4 5 UTP 100 m 328 ft 100BASE TX CAT 5 UTP 100 m 328 ft Shielded twisted pair 150 m 492 ft 1OOBASE FX half duplex multi mode 412 m 1350 ft 1OOBASE FX full duplex multi mode 2 0 km 6 562 ft 1OOBASE FX half duplex single mode 412 m 1350 ft 1O00BASE FX full duplex single mode 20 0 km 6K32T ft 1OO
70. lexibility can be achieved via a family of 6K port modules 6KPM These modules come with copper and fiber built in emphasizing Small Form Factor fiber for high fiber port density 6 port modules for fiber and RJ 45 combinations and 1Gb or 1 1 Dual Gb port module selections using GBIC transceivers in copper or fiber These modules can be factory configured in a base chassis unit or may be changed in the field by trained technicians to adapt the unit as per the user s application and Ethernet media requirements Evolving mixed media requirements for 10Mb and 100Mb fiber copper and 1OOOMb Gigabit ports can be easily handled by the Magnum 6K32TRC product reliably The packaging and wide selection of AC and DC power input options with A8VDC 24VDC 125 110 VDC target the Magnum 6K32TRC for heavy duty applications The chassis rack mounting style as Reverse with the ports and LEDs and the power input and the management console connector all in the rear and a duplicate set of LEDs in the front Rack widths accommodated include standard 19 RETMA ETSI and 23 Telco Input power may be AC or 48 VDC for Telco environments or 24VDC for Industrial and 125VDC for power sub stations applications Designed for primarily use in power sub stations un controlled temperature and Industrial applications the Magnum 6K32TRC provides high performance plug and play hardware operation 802 1p packet prioritization in hardware and indus
71. lf duplex ports to stop incoming traffic 2 2 9 Managed Network Software MNS 6K for Magnum 6K32T amp 6K32TRC Magnum 6K32T amp 6K32TRC come with licensed MNS 6K Firmware Rel 3 2 which allows the configuration of the Magnum 6Ks as a Managed Switch and other Software enabled features For additional information about MNS 6K see the Magnum 6K Series MNS Software User guide in pdf format a separate document normally accessed via your web browser at ftp ftp garrettcom com or FTP client program by fip GarrettCom com using user m6kuser password m6kuser All MNS 6K software information including new releases and upgrades related to MNS 6K software can be accessed and download from GarrettCom s FTP site Alternatively for documentation and latest information on GarrettCom proprietary MIBs for SNMP visit www GarrettCom com techsupport index htm software and look for Magnum MNS 6K info Magnum MNS 6K Operator Training This interactive training software gives the basic and advanced information about the Magnum MNS 6K management software and is a useful tool for a first time user For further information please email support GarrettCom com For upgrading the Magnum 6K32T amp 6K32TRC Switch to its latest Magnum 6K Firmware follow the steps and instruction provided on http www garrettcom com techsupport software upgrade_mns6k pdf _ www GarrettCom com a 20 Magnum 6K32T amp 6K32TRC Managed Swi
72. lush with the front or attached in the center for a set back mounting which may reduce cabling torque The optional 23 brackets and the ETSI 21 brackets each come as a pair in a package along with the necessary screws for attaching the brackets to the sides of the Magnum Switch unit They must be ordered as separate line items 3 3 2 Rack mounting Reverse version of the Magnum 6K32T s Not available as of October 2005 The optional Reverse Magnum 6K32T Model has all of the cabling Ethernet cabling power cabling and console port cabling connectors in the rear and the status LEDs in the front The status LEDs that are co incident with the ports are still present there and a second or dual set of LEDs are used for status visibility in the front of the unit showing the same data Standard Flush Mount Bracket Mid Range Mount or Rear Mount Fig 3 3 2 Reverse Magnum 6K32TRC units rack mounted in a frame _ www GarrettCom com a 35 Magnum 6K32T amp 6K32TRC Managed Switch Installation and User Guide 05 07 There are three options of brackets available to mount in the standard 19 frame 23 frame or ETSI 21 frame The 19 brackets are included with each unit the other two may be purchased as separate options With each bracket type there are three different mounting options as shown in Fig 3 3 2 The case of the Magnum 6K32T has mounting holes prepared for each of the mounting arrangements Users may choo
73. m Inc Printed in the United States of America Magnum 6K32T amp 6K32TRC Managed Switch Installation and User Guide 05 07 Contacting GarrettCom Inc Please use the mailing address phone and fax numbers and email address listed below GarrettCom Inc 47823 Westinghouse Dr Fremont CA 94539 7437 Phone 510 438 9071 Fax 510 438 9072 Website http www GarrettCom com email support garrettcom com Federal Communications Commission Radio Frequency Interference Statement This equipment generates uses and can radiate frequency energy and if not installed and used properly that is in strict accordance with the manufacturer s instructions may cause interference to radio communication It has been tested and found to comply with the limits for a Class A computing device in accordance with the specifications in Subpart J of Part 15 of FCC rules which are designed to provide reasonable protection against such interference when operated in a commercial environment Operation of this equipment in a residential area is likely to cause interference in which case the user at his own expense will be required to take whatever measures may be required to correct the interference Canadian Emission This Class A digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations Cet appareil respecte toutes les exigences du R glement sur le mat riel du Canada Cet appareil est Classe A Regulator
74. mage to the unit 2 Clearly mark the Return Material Authorization RMA number on the outside of the shipping container 3 GarrettCom is not responsible for your return shipping charges 4 Ship the package to GarrettCom Inc 47823 Westinghouse Dr Fremont CA 94539 7437 Attn Customer Service APPENDIX A WARRANTY INFORMATION GarrettCom Inc warrants its products to be free from defects in materials and workmanship for a period of three 3 years from the date of shipment by GarrettCom _ www GarrettCom com a 67 Magnum 6K32T amp 6K32TRC Managed Switch Installation and User Guide 05 07 During this warranty period GarrettCom will repair or at its option replace components in the products that prove to be defective at no charge other than shipping and handling provided that the product is returned pre paid to GarrettCom This warranty will not be effective if in the opinion of GarrettCom the product has been damaged by misuse misapplication or as a result of service or modification other than by GarrettCom GarrettCom reserves the right to make a charge for handling and inspecting any product returned for warranty repair which turns out not to be faulty Please complete the warranty card as this acts as a product registration and mail it to GarrettCom within two weeks of your purchase APPENDIX B Internal DC Power Supply Options B1 0 SPECIFICATIONS FOR MAGNUM 6K32T amp 6K32TRC SWITCHES DC POWER Power
75. n area around the ija j ai ion unit so that cooling can occur from the small fan on the gt AN gi left side while the unit is in operation See figure below Figure 3 1 Location of the Magnum 6K32T s cooling fans 2 Magnum 6K32T amp 6K32TRC Managed Switch Installation and User Guide 05 07 3 2 Connecting Ethernet Media The Magnum 6K32T amp 6K32TRC Switches are specifically designed to support all standard Ethernet media types within a single Switch unit This is accomplished by using a family of different port Modules which can be individually selected and configured per port See Section 2 4 for a description of the PMs The various media types supported along with the corresponding IEEE 802 3 and 802 3u standards and connector types are as follows IEEE Standard Media Type Max Distance Port Module Fiber 1000BASE FX mm Fiber 220m ft GBIC SXSC sgl m Fiber 70km GBIC LXSC 100BASE FX mm Fiber 2 0km 6 562 ft 6K6 MSC MST sgl m Fiber 18 0km 95K ft SSC SSCL small form factor mm Fiber 2 0km 6 562 ft 6K8 MTRJ MLC small form factor sgl m Fiber 15 km 6KP8 SLC Copper 1OBASE T 1OOBASE TX twisted pair 100m 328 ft 6K8 RJ45 1000BASE TX twisted pair 100m 328 ft GBIC TP 1 mm multi mode sol m single mode 3 2 1 Connecting Fiber Optic ST type twist lock The following procedure applies to installations using a PM with ST type fiber connectors This procedure applies to ports using a 6K32T amp 6K32TRC m
76. nd one software alarm through user selectable software traps Per port MDI or MDIX on RJ 45 The copper daughter board has MDI MDIX Auto crossover on all the RJ 45 ports and eliminate the use of cross over cable between the devices Also port specific user settings such as FDX or HDX copper 10 100 speed can be fixed using software commands Agency Approvals UL listed UL60950 cUL CE Emissions meet FCC Part 15 Class A NEBS L3 and ETSI Compliant NEMA TS 2 for traffic control IEEE 1613 Environmental Standard for Electric Power Substations See also Note for Power Substations in Section 3 2 4 3 6 1 and 5 2 9 IEC61850 EMC and Operating Conditions Class C for Power Substations Warranty Three years return to factory Made in USA For a Configuration Guide see the GarrettCom web site at http www garrettcom com techsupport insertion_guides 6k32trcg pdf 6K32 http www garrettcom com techsupport insertion_guides 6k32trccg pdf 6K32TRC Email mktg GarrettCom com for additional details _ www GarrettCom com j 0 0 4 Magnum 6K32T amp 6K32TRC Managed Switch Installation and User Guide 05 07 1 2 Ordering Information Magnum Managed Switch MODEL DESCRIPTION Magnum 6K32T 16 10 100 RJ 45 ports managed switch with two optional port modules 6K32T which may be configured with a selection of 10 100 1000Mb fiber and copper connector types max 32 ports Magnum 6K32T 48VDC Same as 6K32T except power input is 48VDC Magnum
77. odule MST type port 1 Before connecting the fiber optic cable remove the protective dust caps from the tips of the connectors on the PM Save these dust caps for future use 2 Wipe clean the ends of the dual connectors with a soft cloth or lint free lens tissue dampened in alcohol Make certain the connectors are clean before connecting Note One strand of the duplex fiber optic cable is coded using color bands at regular intervals you must use the color coded strand on the associated ports at each end of the fiber optic segment 3 Connect the Transmit TX port light colored post on the Magnum PM to the Receive RX port of the remote device Begin with the color coded strand of the cable for this first TX to RX connection 4 Connect the Receive RX port dark colored post on the PM to the Transmit TX port of the remote device Use the non color coded fiber strand for this 5 The LINK LED on the front of the PM will illuminate when a proper connection has been established at both ends and when power is ON in the unit If LINK is not lit after the cable is connected the normal cause is improper cable polarity Swap the fiber cables at the PM connector to try to remedy this situation _ www GarrettCom com a 28 Magnum 6K32T amp 6K32TRC Managed Switch Installation and User Guide 05 07 3 2 2 Connecting Fiber Optic SC type Snap In The following procedure applies to installations using a PM with SC type fiber conn
78. ons to handle high bandwidth application efficiently The two modular slots are boosted with 1OMb 10 100Mb 100Mb 1000Mb and can be configure with any of modules offered with copper or Fiber media or combo The various PoE modules option is an additional advantage for Magnum 6K32TRC users to provide a secure and economical solution to critical remote applications The preloaded robust and intuitive MNS 6K Managed Network firmware with multiple secured managed features is able to handle industry standard IEEE 802 1p QOS prioritization and non blocking wire speed on all ports It provides high performance switching services for both smooth streaming and bursty data traffic For redundant _ www GarrettCom com a 10 Magnum 6K32T amp 6K32TRC Managed Switch Installation and User Guide 05 07 LANs it offers S ring RS Ring Link Loss Learn STP and RSTP Security features include SNMPv3 SSL SSH 802 1X TACACS Port Security and Tagged VLANs and a secured user friendly web based option The IGMP feature for multicast traffic and streaming video application and IGMP L2 mode feature is an attempt to provide a Layer 3 solution with 6K Switches effectively and economically See MNS 6K materials for further details about Management software http www garrettcom com techsupport software userguides mns6k_webmanual p df web http www garrettcom com techsupport software userguides mns6k_CLI pdf CLI The Magnum 6K32TRC s port f
79. oo GarrettCom Industrial Networking at Its Best Magnum 6K32T amp 6K32TRC 6K32T 6K32TRC ey ne a a musee i e 12 Pi Olle ile a a D a fered LL TT Maka L Lr Ti ne ia Rear View Eo i Managed Switch Installation and User Guide Hardware User Manual _ www GarrettCom com 5 00 USD Magnum 6K32T amp 6K32TRC Managed Switch Installation and User Guide 05 07 Magnum 6K32T amp 6K32TRC Managed Switch Hardware Installation and User Guide Part 84 00138 Rev B Trademarks Ethernet is a trademark of Xerox Corporation NEBS is a trademark of Telcordia Technologies UL is a registered trademark of Underwriters Laboratories GarrettCom Magnum Personal Switch S Ring Link Loss Learn Converter Switch and Convenient Switch are trademarks and Personal Hub is a registered trademark of GarrettCom Inc GarrettCom Inc reserves the right to change specifications performance characteristics and or model offerings without notice Important The Magnum 6K32T amp 6K32TRC Managed Switch contains no user serviceable parts Attempted service by unauthorized personnel shall render all warranties null and void If problems are experienced with Magnum 6K32T amp 6K32TRC Switch products consult Section 6 Troubleshooting of this User Guide Copyright 2007 GarrettCom Inc All rights reserved No part of this publication may be reproduced without prior written permission from GarrettCo
80. orresponding device 3 Use the LINK LED to ensure proper connectivity by noting that the LED will be illuminated when the unit is powered and proper connection is established 3 2 6 Gigabit SFP Small Form factor Pluggable Optical Transceivers The small form factor pluggable SFP is a compact optical transceiver used in optical communications for both telecommunication and data communications applications Due www GarrettCom com 30 Magnum 6K32T amp 6K32TRC Managed Switch Installation and User Guide 05 07 to its compact hot pluggable characteristics SFPs are becoming a very popular choice for various applications The small chassis Magnum 6K is designed for industry standard Gb SFPs and Gb SFPCU copper for user selection of the SFP gigabit media type as desired All SFPs used in Magnum 6Ks are compliant with the industry standard Multi Source Agreement MSA ensuring compatibility with a wide range of networking kit Bail clasp Side View Duplex LC connector Front view Note It is highly recommended to remove the fiber cable first before removing the SFP transceiver for any reason Not removing the fiber cable first can damage the fiber cable cable connector or optical interfaces It is advised not to remove and insert a SFP transceiver frequently as this may shorten its useful life connecting to any Server workstation While connecting with any Switch repeater or Note Always use an ESD wrist stra
81. p 6K32TRC Managed Switch Installation and User Guide 05 07 5 2 1 6KP6 RJMST 4 10 100Mbps RJ 45 and 2 100Mb multi mode FX ST twist 6KP6 RJMST 99 lock Combo 4 Port 10 100Mbps and 2 100 Mb ST Fiber Port Module The Magnum 6KP6 RJMST is a combo 6 port module of RJ 45 s at 10 100Mbps and fiber optic ports at 100MB The Combo 1 LINK 10 100 module is equipped with dual mode ST type connectors and 3 AR LYTE Q eee dual speed copper ports The ST connector functions as a fiber optic transceiver to support 100BASE FX network segments When installed in a Magnum 6K32T amp 6K32TRC Managed Switch the copper port supports the standard distance 100m on each port and the fiber port supports fiber optic cable distances up the IEEE standard 100Mbps distance limits 1 e typically 2km at full duplex and 412m at half duplex Each port has an Activity ACT LED indicating packets being received a Link LK LED that indicates proper connectivity with the remote device when lit and FDX HDX LED to indicate full duplex mode when lit or half duplex when off The 10 100 LED indicates the speed if the LED is ON 100Mbps if it is OFF 10Mbps 5 2 la 6KP6 RJ10ST 4 10 100Mbps RJ 45 and 2 10Mb multi mode FX ST twist lock Combo Module The 6KP6 RJIOST is a six port combo module that looks similar to the 100Mb combo module with the exception of 1OMb speed at the ST fiber module The ST connector functions as a fiber optic transce
82. p while handling the SFP transceivers since the SFP modules are static sensitive devices Note The copper OOOBASE T SFP transceiver port supports 1000Mb only It is recommended to use a straight through RJ 45 4 twisted pair connection while other device it is recommended to use Crossover RJ 45 4 twisted pair category 5 or higher cabling The maximum length supported on copper LOOOBASE T is 100mts 328 ft 31 Magnum 6K32T amp 6K32TRC Managed Switch Installation and User Guide 05 07 The various SFPs transceivers supported by GarrettCom 6KQs D slot are Module Model Gigabit Gb Modules fixed ports SFP Small Form Factor 6KP2 2GSFP 2 SFP 6KP2 1GSFPICU 1SFP 1CU 6KP1 1SFP 1SFP 6KP1 1GCU 1 CU Gb SFP fiber optic transceivers SFP SX Gb SX 850nm wavelength 500 m distance SFP LX10 Gb LX 1310nm wavelength 10km dist SFP LX25 Gb LX 1310nm wavelength 25km distance SFP ZX40 Gb ZX 1550nm wavelength 40km distance SFP ZX70 Gb ZX 1550nm wavelength 70km distance 3 2 7 Power Budget Calculations for Magnum 6K32T amp 6K32TRC PM s with Fiber Media Receiver Sensitivity and Transmitter Power are the parameters necessary to compute the power budget To calculate the power budget of different fiber media installations using Magnum products the following equations should be used OPB Optical Power Budget P min Pp min where Pr Transmitter Output Power and Pr Recei
83. ported by the Magnum 6K32T Switch A main NT server in a secure area protected from earthquake or fire hazards can be connected to one or two full duplex Gigabit Fiber ports Full duplex future proof fiber media can easily connect long distance subnets and provide a stable secure network to all applications The SNMP management capability of the Magnum 6K32T Switch helps create a database of all the network subnets to easily manage the network Secure web based management is also included with authentication and encryption to keep out even determined trouble makers Example 2 In another Telecommunications storage data application a secure managed switch is required to provide an Ethernet backbone for a diversified network with multiple subnets The backbone consists of high speed LAN segments supported by 1000Mbps full duplex future proof fiber media to provide secure long distance LAN connections The entire network is sharing a higher bandwidth Gigabit enabled data mining server for the vital database located in a separate secured building The copper ports are required for multiple subnets inside the building The entire spread network is managed to provide easy detectable uninterrupted support through a viewable SNMP monitor Managed Ffpd 1000Mb Data Mining Servers rea Os es m a a ee d Li r m r ad a or re Ca ame core A O Internet Cas Router 60 Mb Servers and Workstations
84. r for that port must be ON indicating there is a powered up device at the other end of the cable in order for a LK LED to provide valid indications of operating conditions on that port Using the 6K8 Series MNS 6K management software the user may disable auto negotiation and fix the desired operation of each RJ 45 port User may select 10Mb or 1OOMb speed and full or half duplex mode per port as per user requirement See Magnum MNS 6K Software Manual for details info 2 2 3a New PoE Power Inside model PI6KP8 45RJ MDIX 8 port 10 100Mb The New PoE RJ 45 ports act similar to regular RJ 45 ports except they have capability of providing power on each port to PIGKP8V 45RJ 8 Port 10 100Mb POE Copper ports power up the PD devices per the EEE802 3af PoE D kacr QD 10 00 standard Only 4 x RJ 45 10 100 ports PoE C4 FULL HALF maxm support POE Power Inside option in one rack mounted 6K unit The power inside PoE option is factory configured and equipped with the necesasary power option to support four 802 3af PoE pd devices The 4 RJ45 POE module are also available with mix n match with fiber modules Please check the ordering information Sec 1 2 for all the various PI6K PoE modules option The LEDs on 6KP8 RJ45 PoE module are slightly different compared to regular non PoE RJ 45 modules as shown in Fig 2 When the PoE port is in use the 15 Magnum 6K32T amp 6K32TRC Managed Switch Installat
85. rmally draw its power from the DC source with the highest voltage at a given time b The Switch unit will not allow power to flow from a higher voltage input to a lower voltage input i e the two DC power sources are not mixed together by the hub c When one correct DC input is present the Switch will receive power if the other DC input is absent or even if it is connected with reverse polarity or shorted or grounded d Reverse polarity connections if they should accidentally occur on either input will not damage the Switch or power supply internally nor will it blow the fuse in the internal power supply because of the blocking action of the diodes This is true even if one input connection is reversed while the Switch is operating from the other source e The Switch will not receive power and will not work when both inputs are simultaneously absent or are both incorrectly connected C5 0 INSTALLATION This section describes the proper connection of the 48 VDC 24VDC and 125VDC dual source leads to the 48 VDC 24VDC 7 125VDC power terminal block on the Magnum 6Ks Switch shown in Figure The 48VDC terminal block on the Magnum 6K32T amp 6K32TRC Switch as shown in Fig C5 0 is located on the right rear of the unit and is equipped with five 5 screw down lead posts If it is the reverse model it is located on the left rear The primary terminals are identified as positive A negative A and the secondary power terminals a
86. s _ www GarrettCom com a 46 Magnum 6K32T amp 6K32TRC Managed Switch Installation and User Guide 05 07 An address aging algorithm causes least used addresses to fall out in favor of frequently used addresses To reset the address buffer cycle power down and up 4 2 Status LEDs For all Magnum 6K32T amp 6K32TRC models PWR Power LED ON when external power is applied to the unit LK Steady ON Link status for 10 Mbps and 100Mbps operation ACT ON with port activity for 10 Mbps and 100Mbps operation F H Full Half duplex LED ON when the port is running full duplex OFF for half duplex 100 10 Speed LED ON when the speed is 100Mbps OFF when the speed is 10 Mbps 4 3 Auto Cross MDIX Auto negotiation for 10 100Mbps RJ 45 ports The 24 RJ 45 ports on Magnum 6K32T amp 6K32TRC support auto cross MDI or MDIX in the auto negotiation mode according to the IEEE 802 3u standard No crossover cables are needed when connecting the 6K32T amp 6K32TRC s 10 100 copper ports to other unmanaged switches legacy hubs managed switches media converters etc Please note that there can be conditions with managed switches where the switch manager fixes the port settings via software and the result of the auto negotiation is changed in the managed switch by the manager commands In such cases the 10 100 speed or the F H mode may be affected but auto cross in the 6K32T amp 6K32TRC Switches will still work The auto cross funct
87. s Step 1 Make sure the 6KPM Card package has all necessary accessories to install it properly Each 6KPM Card package for field installation contains Daughterboard Bigger and Granddaughter board smaller three 5 8 stand offs for the Granddaughter board six 4 40 Pan Head screws along with a _ www GarrettCom com 37 Magnum 6K32T amp 6K32TRC Managed Switch Installation and User Guide 05 07 Front panel face plate package The Front panel faceplate package includes 3 retainer brackets and six 2 56 flat head screws NOTE Every 6KPM Card package comes with their matching Daughter and Granddaughter board The copper 6KPM card should not work properly if mixed with other Fiber combo 6KPM card packages Always install the PM module separately one by one to avoid the mixing NOTE for Power Substations In support of the IEEE 1613 Class 2 standard GCI advises that for substation applications the serial RJ 45console_ports are intended for temporary connectivity to other equipment such as PCs Since the console port connection is temporary it is excluded from IEEE 1613 packet loss testing per the 1613 standard defined test procedure Step 2 Remove Chassis Cover The Magnum 6K32T amp 6K32TRC chassis are combined with top bottom and front panel parts and assembled together with the help of 17 Philips head screws There are 5 screws located on the front bottom and 3 at rear top of the unit and one each on the front and rear sid
88. s include SNMPv3 SSL SSH 802 1X TACACS Port Security and Tagged VLANs See MNS 6K materials for further details about software The Magnum 6K32T s port flexibility is achieved via a family of 6K port modules 6KPM These modules come with copper and fiber built in emphasizing Small Form Factor fiber for high fiber port density 6 port modules for fiber and RJ 45 combinations and 1Gb or 2Gb port module selections using GBIC transceivers in copper or fiber These modules can be factory configured in a base chassis unit or may be changed in the field by trained technicians to adapt the unit to the user s application and Ethernet media requirements Evolving mixed media requirements for 10Mb and 100Mb fiber copper and Gigabit ports can be easily handled by the Magnum 6K32T amp 6K32TRC product reliably The packaging and power input options target the Magnum 6K32T amp 6K32TRC for heavy duty applications The chassis mounting rack style may be regular with the ports and LEDs in the front and the power input and management console connector in the rear or Reverse with the ports and LEDs and the power input and the management console connector all in the rear and a duplicate set of LEDs in the front Rack widths accommodated include standard 19 RETMA ETSI and 23 Telco Input power may be AC or 48VDC for Telco environments or 24VDC for Industrial applications 2 2 2 Eight port SFF fiber modules 6K8 MTRJ 6K8 M
89. s negative B positive B The chassis earth or ground GND is a threaded post with a 6 nut The Dual Source terminal block for the 24VDC and 125VDC are similar Figure C5 0 48VDC Dual Source wiring connections to the External Terminal Block on a Magnum 48VDC with Dual Source option 36 70VDC 36 70VDC GND Note The GND should be hooked up first The6K32T amp 6K32TRC unit has a floating ground so the user may elect to Ground either or terminal to suit the customer s use Before connecting hot lines to the Terminal Block of 48VDC 24VDC or 125VDC always use a digital voltmeter to measure the output voltage of the power supply and determine the lead which is more ve potential The more ve voltage _ www GarrettCom com a 72 Magnum 6K32T amp 6K32TRC Managed Switch Installation and User Guide 05 07 lead from 48V or 48V supply must be connected to the post labeled The connection procedure is straightforward Simply connect the DC leads to the Switch s power terminals positive and negative screws Ensure that each lead is securely tightened The 24VDC and 125VDC terminal block on Magnum 6K32T amp 6K32TRC s is similar to that described in the 48 VDC information above C5 1 UL Requirements The following must be adhered to in order to conform to UL requirements Minimum 18 AWG cable for connection to a Centralized DC power source Minimum 14 AWG cable for connection to ear
90. s of status monitoring wires at the green terminal block When this option is present the terminal block for Alarm Contacts is part of the Power Input panel in the Magnum 6K32T amp 6K32TRC case The AC or DC power input connection is in the same panel A manual On Off Switch for power to the unit is not available on 6K32T amp 6K32TRC units with the Alarm Contacts option as these two features occupy the same space in the case The first NC Alarm Contact top position is a Software Alarm operated by user settings in the MNS 6K software The user can disable the Software Alarm feature with a software configuration command if desired When the Software Alarm is enabled the Form C Normally Closed NC contact is held close during normal software operation A user defined software malfunction such as an SNMP Trap or a Software _ www GarrettCom com 36 Magnum 6K32T amp 6K32TRC Managed Switch Installation and User Guide 05 07 Security violation or an S Ring Fault causes the contact to open and thus trigger an alarm in the user s monitoring system The second bottom position NC Alarm Contact is held close when there is power on the main board inside of the 6K32T amp 6K32TRC This provides a Hardware Alarm because the NC contacts will open when internal power is lost either from an external power down condition or by the failure of the power supply inside of the Magnum 6K32T amp 6K32TRC Switch Useful info about Alarm conta
91. s shown in above fig with arrow mark Fig 3 5 2d Daughter Board shown upside down with two male latch connectors Step 4 Hold the daughter board with both hands at the end and align the two cream color latching connectors male placed at the bottom of the daughter board with Fig 3 5 2e Daughter Bd Being placed over the Grand daughter Bd and the mating connector being matched to lockup properly the other female connector placed on the Granddaughter and main board As shown above in Fig 3 5 2e Step 5 Once the latching connectors are aligned properly and the mounting holes are aligned with stand offs then press slowly and firmly with two fingers as shown below in Fig 3 5 2f on the top of the latching connectors until the connectors latched www GarrettCom com 41 Magnum 6K32T amp 6K32TRC Managed Switch Installation and User Guide 05 07 Fig 3 5 2f Securely latching up 6KPM Cards into a Magnum 6K32T amp 6K32TRC amp 6K32 NOTE When leaving 6KPM slots empty always use a face plate Magnum 6K8 BLNK to cover the slot opening in the front panel This will maintain proper cooling air flow safety and operation as required by FCC CE and other regulations Step 6 Now screw down the daughter board with 7 440 screws except the last two at the end so that it holds the daughter board securely The figure below shows the top view of 6KPM card after successfully installing the 6KPM cards insi
92. se the mounting arrangement most suitable for their installation 3 4 Powering the Magnum 6K32T amp 6K32TRC Managed Switch The Magnum 6K32T amp 6K32TRC Switches incorporate an internal universal power supply and have a recessed male IEC connector for the AC power cord at the left rear A manual power ON OFF switch is adjacent A six foot 115 VAC 60 Hz standard power cord is supplied with each unit shipped within the United States and Canada The auto ranging power supply supports installation environments where the AC voltage is from 90 to 260 volts with a power input frequency between 47 and 63 Hz The 32 port units will consume over 30 watts of power typically When connecting the Ethernet cabling there is no need to power down the unit Individual segments can be connected or disconnected without concern for AC power related problems or damage to the unit Power supply options are available to suit the 6K32T amp 6K32TRC Switches to special high availability communications and or heavy industrial grade applications including 48VDC 24VDC and 125VDC with single DC input 48VDC 24VDC and 125VDC with dual source DC input See the Appendices of this manual for more details Use an RFQ for other variations 3 4 1 Alarm Contacts for monitoring internal power and Software Traps The Alarm Contacts feature optional on Magnum 6K32T amp 6K32TRC s provides two Form C Normally Closed NC contacts to which the user can attach two set
93. settings and can check the port status of each port after the change When Magnum 6K32T amp 6K32TRC RJ 45 copper ports are set for auto negotiation and are connected to another auto negotiating device there are 4 different speed and F H modes possible depending on what the other device supports These are 1 1OOMb full duplex 2 100Mb half duplex 3 10 Mb full duplex and 4 10 Mb half duplex General information Auto negotiation per port for 802 3u compliant switches occurs when the devices at both ends of the cable are capable of operation at either 10 Mb or 100Mb speed and or in full or half duplex mode and can send receive auto negotiation pulses and the second of the two connected devices is powered up 1 e when LINK is established for a port or the LINK is re established on a port after being lost temporarily e NOTE Some NIC cards only auto negotiate when the computer system that they are in is powered up These are exceptions to the negotiate at LINK enabled rule above but may be occasionally encountered The auto negotiation logic will attempt to operate in descending order and will normally arrive at the highest order mode that both devices can support at that time Since auto negotiation is potentially an externally controlled process the original highest order mode result can change at any time depending on network changes that may occur If the device at the other end is no
94. source and four 100 Mb 15km sm FX LC connectors New P6KP8 45 2MT 6 2 port PoE module for 6ks with 48vdc PS w four PoE power source and two normal RJ 45 10 100 ports twol00 Mb 2km mm FX MTRJ connectors New P6KP8 452SLC 6 2 port PoE module for 6ks with 48vdc PS w four PoE power source and four 100 Mb 15km Sm FX LC connectors New P6KP6 RJMST 4 2 port PoE module for 6ks with 48vdc PS w four PoE power source and two 100 Mb 2km mm FX ST connectors New P6KP6 RJMSC 4 2 port PoE module for 6ks with 48vdc PS w four PoE power source and two 100 Mb 2km mm FX SC connectors New P6KP6 RJSSC 4 2 port PoE module for 6ks with 48vdc PS w four PoE power source and two 100 Mb 20km sm FX SC connectors New P6KP6 RJSSCL 4 2 port PoE module for 6ks with 48vdc PS w four PoE power source and two 100 Mb 40km sm FX SC connectors New P6KP6 RJ10ST 4 2 port PoE module for 6ks with 48vdc PS w four PoE power source and two 10 Mb 2km sm FL ST connectors 6K32T 6K32TRC PoE Modules with 48VDC Power Inside NOTE For configuring in 6K Switches having AC 125VDC power input Configuration options only one A or B module slot of 6K32 Series switch with 48VDC power input may be configured with a PoE Modules New 6KAC PoE PS Power supply for PoE to 4 ports 60 watts mounts inside of a full width rack mount 6K switch with AC power input New 6K125VDC PoE PS Power supply for PoE to 4 ports 60 watts mounts inside of a full wi
95. t an auto negotiating device the 6K32T amp 6K32TRC s www GarrettCom com NNN 48 Magnum 6K32T amp 6K32TRC Managed Switch Installation and User Guide 05 07 RJ 45 ports will try to detect its idle signal to determine 10 or 100 speed and will default to half duplex at that speed per the IEEE standard When operating in 100Mb half duplex mode cable distances and hop counts may be limited within that collision domain The Path Delay Value PDV bit times must account for all devices and cable lengths within that domain For Magnum 6K32T amp 6K32TRC Fast Ethernet switched ports operating at 1OOMb half duplex the bit time delay is 5OBT 4 4 Flow control IEEE 802 3x standard Magnum 6K32T amp 6K32TRC Switches incorporate a flow control mechanism for Full Duplex mode The purpose of flow control is to reduce the risk of data loss if a long burst of activity causes the switch to save frames until its buffer memory is full This is most likely to occur when data is moving from a 100Mb port to a 10 Mb port and the 1OMb port is unable to keep up It can also occur when multiple 1OOMb ports are attempting to transmit to one 1OOMb port and in other protracted heavy traffic situations Magnum 6K32T amp 6K32TRC Switches implement the 802 3x flow control non blocking on Full Duplex ports which provides for a PAUSE packet to be transmitted to the sender when the packet buffer is nearly filled and there is danger of lost packets The
96. t modules in the family to choose from The port modules are normally factory installed and tested but may be changed in the field Rack mounting may be standard or reverse 19 inch or ETSI or 23 Telco The standard rack mounting provides Ethernet ports and status LEDs in front service connections power input and management console in the rear Reverse rack mounting provides status LEDs in front and all cabling connections in the rear Standard 19 rack mount brackets are included with ETSI and 23 Telco optional Standard AC power input 48VDC or 24VDC or 125VDC input is optional Standard AC power input has an IEC plug and is auto ranging for worldwide use For special applications models with 48VDC or 24VDC or 125VDC are available Dual Source DC input can also be selected and configured on the DC power input models Heavy duty design for Telco NEBS tested and other industrial environments Fiber ports take more power than copper ports but the Magnum 6K32T amp 6K32TRC design provides for this with heavy duty components The ambient temperature can be up to 55 C www GarrettCom com 21 Magnum 6K32T amp 6K32TRC Managed Switch Installation and User Guide 05 07 E MNS 6K licensed Network Management Software included S Ring RS Ring optional Release 3 5 summer 06 includes SNMP Secure Web Management RMON CLI Port Security Port Mirroring Port Settings Control Telnet TFTP FTP support Spanning
97. tch Installation and User Guide 05 07 2 3 Features and Benefits Managed switching for high performance Ethernet LANs Magnum 6K32T amp 6K32TRC amp 6K32TRC Switches provide non blocking all ports can run at full speed at once performance with standard Managed Networks Software MNS 6K included They are typically used in LAN traffic centers with 24 10 100Mb ports or one or two Gigabit ports for backbone connections where managed network services are desired Switching services includes 802 1p QoS packet prioritization The Magnum 6K32T amp 6K32TRC switching hardware supports QoS giving packet processing priority to priority tagged packets according to the IEEE 802 1p standard For port and application specific priorities the QoS software may be configured by the user Features Fiber Built In Magnum 6K32T amp 6K32TRC Managed Switches are designed with modular slots to naturally include fiber ports and support mixes of the following multi mode and single mode 10 Mb 100Mb and 1000Mb speed full and half duplex and classic Small Form Factor SFF and GBIC fiber connectors RJ 45 10 100 ports can also be configured in the mix of port types Modular design for port flexibility in a 1U space saving rack mount package The 1U Magnum 6K32T amp 6K32TRC chassis has slot for port configurations A family of 2 4 6 or 8 port modules allows the user to select the desired mix of port types and speeds There are over 20 differen
98. thing wiring Use only with Listed 10 A circuit breaker provided in building installation Complies with FDA radiation performance standards 21 CFR subchapter J or equivalent Fastening torque of the lugs on the terminal block 9 inch pound max 6 Centralized DC Power Source cable securement use at least four Minimum 14 AWG cable ties to secure the cable to the rack at least 4 inches apart with the first one located within 6 inches of the terminal block Bw DS m C6 0 ORDERING INFORMATION To order the optional Dual Source 48 VDC power supply factory installed order Dual Src48V as a separate line item following the product model Example Magnum 6K32T amp 6K32TRC 48VDC Dual Src 48V_ for the regular DS model with no ON OFF switch or Dual Src48V SWITCH with the ON OFF manual switch Similarly order the Dual source 24VDC or Dual source 125VDC as a separate line item following the product model Example Magnum 6K32T amp 6K32TRC 24VDC or Magnum 6K32T amp 6K32TRC 125VDC Dual Srce24V for regular models with no ON OFF switch Or Dual Src125V Switch for models with the ON OFF switch C7 0 OPERATION Operation of the Dual Source Magnum 6Ks 48 VDC 24VDC and 125VDC Switch models are identical to that of the standard models 73
99. transceiver module for use in GBPM xOTX One 1000BASE LX LH port with 1310nm single mode SC 10km fiber connector GBIC LXSC25_ GBIC transceiver module for use in GBPM xOTX One 1OOOBASE LX LH port with 1310nm single mode SC 25km fiber connector GBIC LXSC40 GBIC transceiver module for use in GBPM xOTX One 1OOOBASE ZX port with 1550nm single mode SC 40km fiber connector GBIC LXSC70 GBIC transceiver module for use in GBPM xOTX One 1OOOBASE ZX port with 1550nm single mode SC 70km fiber connector GBIC TP GBIC transceiver module for use in GRBPM xOTX One 802 3ab 1O00BASE T port with RJ 45 connector Modules with Gb not using GBICs 6KP5 1CU4RJ G 4 module with one GBIC copper Auto negotiating transceiver and four 10 100 RJ 45 connectors includes front panel metal sheet 6KP5 1CU4MT G 4 module with one GBIC copper Auto negotiating transceiver and four 1OOMb MTRJ Fx Multi mode connectors includes front panel metal sheet 6KP3 1CU2FXT G 2 module with one GBIC copper Auto negotiating transceiver and four 100Mb ST Fx Multi mode connectors includes front panel metal sheet 6KP2 2GSX_ two port in one slot Gigabit 6K module uses one 6K slot and provides two Gb Fiber SXSC LOOOBASE SX Multi mode ports includes front panel metal sheet 6KP2 2GCU _ two port in one slot Gigabit 6K module uses one 6K slot and provides two Gb Copper LOOOBASE RJ45 Auto negotiating ports includes front panel metal sheet 6K
100. try standard _ www GarrettCom com a 11 Magnum 6K32T amp 6K32TRC Managed Switch Installation and User Guide 05 07 managed networks software functionality with plenty of secure and remote monitoring features all in convenient 1U rack mount packages 2 2 la Magnum 6K32T Managed Switch Chassis The high port density and fan cooled Magnum 6K32T was designed for heavy duty Carrier class and Industrial applications that require high port density and secure devices which save in cost rack space and running cool to provide reliable solutions This rack mountable managed switch comes with a wide variety of AC DC options to deliver an effective and efficient solutions for the required application needs The 6K32T Switches have 1 6port fixed RJ 45 10 100Mb ports and 2 modular slots available to configure with numerous 6KPM options The options can be RJ 45 or fiber media 10 or 100 or L1OOOMb copper or Fiber or Small Form Factor options to provide more fiber ports The two modular slots can be configure with maximum of four Gigabit modules as shown in Fig 2 2 1 b Figure 2 2 1b 6K32T front view configured for16 RJ 45 ports 2 Modular slot with Dual Giga module The modular option with two slots explores this managed switch s extra capability to meet any 10 or 100 or Gigabit requirement effectively satisfying any demand for complex Ethernet The Triple Play demand of bandwidth to meet voice data video over Ethernet will be han
101. ts or G 2 100Mb fiber ports as shown below in the above figure Each port has an Activity ACT LED indicating packets being received and a link LK LED indicating proper connectivity with the remote device when lit 5 2 13 6KM BLNK The 6K8 BLNK is a blank face plate or cover plate that must be installed in any empty 6K32T amp 6K32TRC PM slot to maintain proper cooling air flow safety etc Two screws underneath the front panel hold the 6K M BLNK in place 64 Magnum 6K32T amp 6K32TRC Managed Switch Installation and User Guide 05 07 6 0 TROUBLESHOOTING All Magnum Ethernet products are designed to provide reliability and consistently high performance in all network environments The installation of a Magnum 6K32T amp 6K32TRC Switch is a straightforward procedure see INSTALLATION Section 3 0 the operation is also straightforward and is discussed in Section 4 Should problems develop during installation or operation this section is intended to help locate identify and correct these types of problems Please follow the suggestions listed below prior to contacting your supplier However if you are unsure of the procedures described in this section or if the Magnum 6K32T amp 6K32TRC Switch is not performing as expected do not attempt to repair the unit instead contact your supplier for assistance or contact GarrettCom Customer Support 6 1 Before Calling for Assistance l If difficulty is encountered wh
102. two 100 Mb 40km sm FX SC connectors New PI6KP6 RJ10ST 4 2 port PoE module for 6ks with 48vdc PS w four POE power source and two 10 Mb 2km sm FL ST connectors GarrettCom Inc reserves the right to change specifications performance characteristics and or model offerings without notice Magnum 6K32T amp 6K32TRC Managed Switch Installation and User Guide 05 07 2 0 Introduction 2 1 Inspecting the Package and Product Examine the shipping container for obvious damage prior to installing this product notify the carrier of any damage that you believe occurred during shipment or delivery Inspect the contents of this package for any signs of damage and ensure that the items listed below are included This package should contain 1 Magnum 6K32T 6K32TR or 6K32TRC Managed Switch base unit configured with user selected port module option in modular slot 1 AC Power Cord U S and other 115 VAC only 1 Set of metal Ears for 19 rack mounting 1 Installation and User Guide this manual 1 Product Registration Card Remove the items from the shipping container Be sure to keep the shipping container should you need to re ship the unit at a later date To validate the product warranty please complete and return the enclosed Product Registration Card to GarrettCom Inc as soon as possible In the event there are items missing or damaged contact the party from whom you purchased the product If the unit needs to be return
103. ver Sensitivity Worst case OPB OPB 1dB for LED aging 1dB for insertion loss Worst case distance Worst case OPB in dB Cable Loss in dB Km where the Cable Loss for 62 5 125 and 50 125um M m is 2 8 dB km _ www GarrettCom com 32 Magnum 6K32T amp 6K32TRC Managed Switch Installation and User Guide 05 07 and the Cable Loss for 100 140 Multi mode is 3 3 dB km and the Cable Loss for 9 125 Single mode is 0 5 dB km and the Cable Loss for 9 125 Single mode is 0 4 dB km LXSC25 and the Cable Loss for 9 125 Single mode is 0 25 dB km LXSC40 and the Cable Loss for 9 125 Single mode is 0 2 dB km LXSC70 The following data has been collected from component manufacturer s Agilent s and Lucent web sites and ae to provide pulcanc to network designers and installers Fiber Port Module 10Mb Multi ag 62 ol 31 5 17 FL Mode 7 5 31 119 5 5 9 23 5 5 31 195 3 4 13 5 6KPM 100Mb Multi 2 39 62 5 125 20 31 9 0 3 0 14 MST MSC FX mode 0 4 Pr ET a PI skpem ssc OM Single 18 6KPM 6KPM SSC me a o f 1300 jonas gs seen ee ee 1300 9 125 32 5 FX mode os SSCL 6KpM 100Mb Multi 1309 625 125 20 90 3 0 15 8 MTR EX mode 04 50 125 23 5 5 5 2 0 12 2 6KPM 100Mb Multi 1300 62 5 125 19 MLC FX mode ae 6KPM pKPMSLC 100Mb Single 1310 9 125 15 Mode GBIC poe Multi 0 55 s50 625 125 9 5 1
104. with RSTP enabled and bottom in the nng with S ring controlled by Switch s network Camera zE 13 Axis 205 a mm a ae nebuork PE ees sd ASS ee Enika J ett SE SE De ael 1 epep 11 e A ii An ete See porter netvuork Camera All the bottom Switches i Ring enabled wath Link j Axis 205 Loss Legrn m Tm E network ial 1 oa f Camera Target Target 6K382TRC in a Redundant application Example 4 In a video data application where a network being designed to catered the need of multicast streaming and broadcast traffic of higher bandwidth to provide a video conferencing and video in demand channel option to the user The Magnum 6K32TRC with two slots filled with Gigaport module and a robust management firmware with MNS 6K qualify this requirement efficiently The New IGMP L2 Mode feature on Magnum 6K32TRC and loaded with management capability and secure web feature fulill this requirement effectively The Dual Giga option on each of the two slot add 4 Gigaport to handle the bandwidth requirement and 16 10 100 RJ 45 ports to feed the other needs of equipment connected to the 6K32TRC The robust Tag based vlan feature will able to segregates different ports belong to one group and provide an effective solution for bandwidth The SNMP option and secure web based will allow the remote capability and monitoring the network securely The versatile mechanical design with rack mounting capa
105. yUL60950 Voltage Range 18 36VDC 24vdc option 38 60VDC 60vdc option 100 I150VDC 125vdc option 100 240Vac AC option Test Temp 40 C 11 Magnum 6K32T amp 6K32TRC Managed Switch Installation and User Guide 05 07 TABLE OF CONTEN TS ecir aa Page LO SPECIEI ATIONS cosson SEEE TE 2 1 1 Technical Specifications sesisitansiiasi i a i 2 1 2 Ordering Information cccceeessssssseeeececeeeeeeeecaeeeesseeeeeeseeeeeeeeeeeeeeeeaas 5 20 INTRODUCTION arnan 9 2 1 Inspecting the Package and Product cccccsseseeeeceeeeeeeeeeaeeeeeeeeees 9 2 2 Product Description Magnum 6K32TRC Managed Switch 10 2 2 la Magnum 6K32T Managed Switch Chassis ccccccccceeseeees 12 2 2 2 Eight port SFF fiber modules 6K8 MTRJ 6K8 MLC 13 2 2 3 Eight Port Copper Module 6K8 RJ45 MDIX ee 14 2 2 3a New PoE Power Inside PI6KP8 45RJ MDIX 8 port 10 100Mb 15 2 2 3b New PoE Power Pass through POKP8 RJ45 MDIX 8 port 16 2 2 4 Six Port 4 2 Combo Modules fiber ST or SC ee 16 225 Four Port 10 Mb mm Fiber ST Modules eeeeeeeees 17 22 6 Gigabit LOOOMbps port modules cc eeeseesesssseeeseeeeeeeees 18 2 2 7 Packet Prioritization 802 1p QOS seeesssssssssssssssssssseseeresssssss 19 2 2 8 Frame Buffering and Flow Control cccccsseeeeeeeeeeeeeeeeeeees 19 2 2 9 Managed Network Software 6K32T amp 6K32TRC 20 2 3 Features an

Download Pdf Manuals

image

Related Search

Related Contents

MESOVEX E 120 X  Premier Copper Products BV15DB2 Installation Guide  2013 Dodge Charger Owner`s Manual - Dealer e  SR-V10U Instruction manual (1MB, PDF)  ECE 481 Senior Design Project Final Report    Kramer Electronics 690T  User Manual, Anybus Communicator for CANopen  Manuel de service  Samsung EcoGreen HD203WI hard disk drive  

Copyright © All rights reserved.
Failed to retrieve file