Home
FA-UNIT-F11BE, FA-UNIT
Contents
1. FA UNIT F11ME A R2 5 6 000000000000000 LU KU gu _ pe E pem i l WS 38 2 m 8 I 845 ql 380 2 396 364 mm Figure 2 6 Dimensions lt FA UNIT F11ME Horizontally placed gt CONTEC 10 FA UNIT F11BE FA UNIT F11ME 2 Name of Each Part and Dimensions Diagram R45 R25 v po IS ET ds T otto oae Nas ab N845 80 160 80 16 420 177 st m E S mm lt lt lt o Figure 2 7 Dimensions lt FA UNIT F11ME Vertically placed gt CONTEC FA UNIT F11BE FA UNIT F11ME 11 2 Name of Each Part and Dimensions Diagram Positions of backplane or motherboard installation holes 18 38 233 68 213 36 208 175 26 139 62 10 137 16 SS 7 162 S 30 48 gt 20 62 1516 12 7 2 H a amp a i Et p je Ht 81 5 i N ENSIS c E E E M z t L 4 i AINIS
2. ls St EE 1 vos Ef 1 M 1 2 c 1 5 cce 381 211 63 246 38 mm Figure 2 8 Positions of backplane installation holes If a backplane or motherboard whose shaded area is not cut off is installed then a 3 5 inch or 5 inch drive may not be installed properly depending on the height of the installed parts etc CONTEC 12 FA UNIT F11BE FA UNIT F11ME 3 Installing the Motherboard 3 Installing the Motherboard Installing the backplane motherboard There are various types of backplanes and motherboards and their installation hole positions are all different However basically any of them can be installed by following the same procedures Preparation 1 Turn the power switch off 2 Pull the power plug of the unit from the wall outlet To install the backplane motherboard eA 1 Remove the screws fastening the top cover then remove the cover When loosening the screws use the appropriate type of screwdriver that fits the screw head 2 First remove the fall off prevention bar from the expansion board Next fix the attached hexagon spacers or plastic spacers to the holes in the main unit and place the backplane motherboard on it and fix it with screws In this case select the positions of fixing holes so that the backplane or motherboard can be fixed in a balanced manner 3 Return the fal
3. Operating temperature Operating humidity 10 80 RH No condensation Storage temperature as NEB 1 The values in the above are constrained with the boards or the components such as drives installed inside the product so the figures do not necessarily represent the tolerances for every operating condition Dimensions of installable board Max 340 5 220 0 L L is a alf size case mm A CAUTION The internal power supply and cooling fan fan filter are consumables requiring replacement after 122 0 H use for a certain period of time Although the standards are given below their lives may be shortened depending on the operating environment The life span is likely especially to become short extremely in the place which takes influence of trash metallic powder the place which is much dust or oil corrosive gas Power supply About 5 years 25 C 60 official environment Cooling Fan 5 years 25 C 60 official environment Fan filter About 1 year 25 C 60 official environment CONTEC 26 FA UNIT F11BE FA UNIT F11ME FA UNIT F11BE FA UNIT F11ME User s Manual CONTEC CO LTD November 2006 Edition 3 9 31 Himesato Nishiyodogawa ku Osaka 555 0025 Japan Japanese http www contec co jp English http www contec com Chinese http www contec com cn No part of this document may be copied or reproduced in any form by any means witho
4. Installing the Motherboard Installation conditions To prevent a temperature rise install this chassis at a distance of at least 50mm from obstacles such as walls i e 5 29 50 Front Side View Rear Side View EE E o ial Front Side View el Rear Side View mm Figure 3 3 Installation conditions CONTEC FA UNIT F11BE FA UNIT F11ME 19 3 Installing the Motherboard Installing the wall mount bracket Installing the attached bracket enables wall mount The bracket can be installed in two ways Install the bracket using an appropriate method in accordance with the use environment lt Horizontally Placed gt lt Placed gt Figure 3 4 Installing the wall mount bracket CONTEC 20 FA UNIT F11BE FA UNIT F11ME 4 Connectors 4 Connectors Power Supply This product has built in power supply units The backplane or motherboard power supply connector and HDD and FDD power supply connectors are provided Connecting these connectors enables the motherboard HDD and FDD to operate Backplane or motherboard power supply connectors It connects it with Backplane or the motherboard Pin Function 3 Figure 4 1 Backplane or motherboard power supply connectors HDD FDD power supply connectors YELLOW 1 1
5. Table Of Contents E TRIN EROR FERNER UK ae aby iii 1 BEFORE USING THE PRODUCT 1 About the Chassis x IIS 1 SEATS vade OON OA EMG ORNARE MEE VERANTA NUR NEN ER TAN ERA MEN ERAN A EIGENEN ER D 1 Customer SUPP OL 3 Web M 3 Limited One Year Warranty oce eee xen 3 Howto Obtain Service eee teret ren er RENE ene oH a Ce e PNE tes 3 BE oM 3 Safety Precautions cocti iie p ED EP nae ated ETETE PERSE THER eI 4 ruant P 4 Handling Precautionis nep e RUPEE e Ur eec Rye e e gere ti 5 E yitonmeht 22 rta mte ne RHODE BE ri C Et e pa e HERE EE 6 Inspection T Disposals 6 2 NAME OF EACH PART AND DIMENSIONS DIAGRAM 7 Partsiof the Chassis RR 7 Front Side VJew E E A ET 7 Rear Side Vie we iit clie EO eH DET ER I E EEER UR HE PERIERE HERE e OQ TERR Ede ed Eats 7 IDA OI 8 FA UNIT F11BE FA UNIT F11ME Positions of backplane or motherboard installation holes eere 12 3 INSTALLING THE MOTHERBOARD 13 Installing the backplane motherboard sese tenne nnn 13 luca M 13 To install the backplane motherboard 0 eee ces eeeeeeee
6. sample programs available in several languages Note For product information Contact your retailer if you have any technical question about a CONTEC product or need its price delivery time or estimate information Limited One Year Warranty CONTEC products are warranted by CONTEC CO LTD to be free from defects in material and workmanship for up to one year from the date of purchase by the original purchaser Repair will be free of charge only when this device is returned freight prepaid with a copy of the original invoice and a Return Merchandise Authorization to the distributor or the CONTEC group office from which it was purchased This warranty is not applicable for scratches or normal wear but only for the electronic circuitry and original products The warranty is not applicable if the device has been tampered with or damaged through abuse mistreatment neglect or unreasonable use or if the original invoice is not included in which case repairs will be considered beyond the warranty policy How to Obtain Service For replacement or repair return the device freight prepaid with a copy of the original invoice Please obtain a Return Merchandise Authorization number RMA from the CONTEC group office where you purchased before returning any product No product will be accepted by CONTEC group without the RMA number Liability The obligation of the warrantor is solely to repair or replace the product In no event will the
7. 15 3 Installing the Motherboard Replacing the connector plate The supplied connector plate has holes for accepting connectors If necessary the supplied connector plate can be replaced with another plate of different shape Figure 3 1 Replacing the connector plate CONTEC 16 FA UNIT F11BE FA UNIT F11ME 3 Installing the Motherboard Installing Disk Drives FA UNIT F1 IBE FA UNIT F11ME can have two 5 inch drives and two 3 5 inch drives built in it Preparation 1 Turn the power switch off 2 Pull the power plug of the unit from the wall outlet Installing Disk Drives 1 Remove the screws fastening the top cover then remove the cover When loosening the screws use the appropriate type of screwdriver that fits the screw head CONTEC FA UNIT F11BE FA UNIT F11ME 17 3 Installing the Motherboard 3 Remove the drive fixing bracket and install drives Connect the cables and fix them to the original position of the chassis 4 Return the fall off prevention bar and cover to their original positions and fix them with screws Installing Removing a fan and filter You can install remove a fan and filter without removing the top cover Relay connector Finger guard Filter a Mi lii FAN cover The installation of the fan is obtained in the reverse order of detaching Figure 3 2 Installing Removing a fan and filter CONTEC 18 FA UNIT F11BE FA UNIT F11ME 3
8. 2V BLACK BLACK RED gt ToHDD or CD ROM gt To3 5inch FDD Figure 4 2 HDD FDD power supply connectors CONTEC FA UNIT F11BE FA UNIT F11ME 21 4 Connectors Switches and LEDs This product has two switches and two LEDs at the front One of the switches is the power switch for turning the power supply on and off The green LED POWER comes on when you turn the power on The second switch is the reset switch for rebooting the system The red LED HDD indicates the access status of the hard disk drive These switches and LEDs operate with their respective connector cables connected to the corresponding connectors on the SBC CPU board 1 Power SW White 2 Power LE Black Green Black 3 HDD LED Red Black 4 Reset SW Yellow Black Figure 4 3 Switch and LED Connector Cables CONTEC 22 FA UNIT F11BE FA UNIT F11ME 4 Connectors USB Connector This product has two ports for USB cable external connection connectors The USB connector operates when a cable is connected to the relevant connector on SBC CPU board with a USB internal connection connector CHASSIS GND Pin 10 lt GND Ping USBP24 Pin6 4 USBP2 Pin4 4 VCC2 2 SX Pin 9 N C Pin7 GND Pin 5 USBP1 Pin 3 USBP1 Pin 1 VCC1 Figure 4 4 USB Connector Cable CONTEC FA UNIT F11BE FA UNIT F11ME 23 4 Connectors CONTEC 24 FA U
9. NIT F11BE FA UNIT F11ME 5 System Reference 5 System Reference Specification Table 5 1 General specifications Specification Item FA UNIT F11BE FA UNIT F11ME Number of user slots 9 full size slot 4 full size slot 2 half size slot Installable board mm Full size 340 5 L x 122 0 H Max Half size 220 0 L x 122 0 H Max Rack mountable EIA 19 inch rack mountable Fan Inlet x 1 Inlet x 1 Outlet x1 Excluding power supply fan Excluding power supply fan Drives 5 inch x 2 3 5 inch x 2 Number of slot holes 11 Installable Backplane dimensions 246 4 W x 264 2 D Max For details see Figure 2 8 BPM 1111 BPI 1111 BPC 1111 Installable motherboard Micro ATX size dimensions mm 246 4 W x 264 2 D Max For details see Figure 2 8 364 W x 177 H x 420 D Excluding raised parts Weight About 11kg Excluding backplane motherboard drives etc Table 5 2 Power supply specifications Power capacity 1 45V 25A 5V 0 3A 43 3V 25A 12V 0 8A 12V 15A 45VSB 2A Overall maximum 300W power supply capacity AC Power Voltage 2 115VAC 230VAC 50 60H z SW selection Input current 10A 115VAC 5A 230VAC AC Outlet 1 Total of 5V and 3V shall not exceed the power of 200W 2 Input voltage range for AC power supply 90 132VAC 180 250VAC CONTEC FA UNIT F11BE FA UNIT F11ME 25 5 System Reference Table 5 3 Environment specifications Item Specification
10. SBC Series Full Size 11 slots Chassis FA UNIT F11BE Full Size MicroATX Chassis FA UNIT F11ME User s Manual CONTEC CO LTD Check Your Package Thank you for purchasing the CONTEC product The product consists of the items listed below Check with the following list that your package is complete If you discover damaged or missing items contact your retailer Product Configuration List lt FA UNIT F1 1BE gt Chassis FA UNIT F11BE 1 Bracket for wall mounted 2 Power cable 1 Slot cover 11 Rubber pads 4 User s Manual 1 Screws for Rubber pads M4 x 8 6 Screws used for expansion bay fixing and board installation M3 x 6 32 Screws for HDD 6 32UNC x 5 8 Hexagon spacer 13 Plastic Spacers 5 9 x8 Rubber pads Screws for HDD EM 6 Screws for Rubber pads D x13 x32 Hexagon spacer Slot cover Screws used for expansion Chassis Power cable bay fixing and board installation User s Manual 2 A Plastic Spacers Bracket for wall mounted User s Manual CONTEC FA UNIT F11BE FA UNIT F11ME Product Configuration List FA UNIT F11ME gt Chassis FA UNIT F11ME 1 Plastic Spacers 3 Power cable 1 Bracket for wall mounted 2 Rubber pads 4 Slot cover 4 Screws for Rubber pads M4 x 8 6 This User s Manual 1 Screws used for expansion bay fixing and board installatio
11. accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference at his own expense WARNING TO USER Change or modifications not expressly approved the manufacturer can void the user s authority to operate this equipment CONTEC 4 FA UNIT F11BE FA UNIT F11ME 1 Before Using the Product Handling Precautions N CAUTION A If you turn the power switch off wait for at least five seconds before turning it on again When plugging or unplugging the power cable be sure to hold the plug itself Since the product is a precision device do not use or store it where it is subject to shock or vibration Also avoid any place where the unit is exposed to direct sunlight extremely high or low humidity or much dust Do not use or store this product where it is exposed to any chemical directly or as vapor in the air This product has ventilating slits to prevent it from being heated excessively Avoid using the unit with the ventilating slits blocked or in an ill ventilated place Do not use this product near equipment generating a strong magnetic field or noise or the field or noise may cause this product or personal computer to malfunction It is very dangerous to use this product with water liquid or metal conductive chips left inside Be careful not to let such foreign matters in this product When ins
12. he Product Environment Use this product in the following environment If used in an unauthorized environment the board may overheat malfunction or cause a failure Operating temperature 0 50 C Operating humidity 10 80 RH No condensation Corrosive gases None Floating dust particles Not to be excessive Inspection Inspect the product periodically as follows to use it safely Ventilating slits must neither be blocked nor have dust or foreign matters adhering Front side view Rear side view FA UNIT F 11BE Ta I aan Ventilating slits must neither be blocked nor have dust or foreign matters adhering Storage When storing this product keep it in its original packing form 1 Put this product in the storage bag 2 Store the package at room temperature at a place free from direct sunlight moisture shock vibration magnetism and static electricity Disposal When disposing of the product follow the disposal procedures stipulated under the relevant laws and municipal ordinances CONTEC 6 FA UNIT F11BE FA UNIT F11ME 2 Name of Each Part and Dimensions Diagram 2 Name of Each Part and Dimensions Diagram Parts of the Chassis Front Side View POWER Reset switch HDD access LED LED POWER Switch USB port Fan replacement hatch Fig
13. l off prevention bar and cover to their original positions and fix them with screws CONTEC FA UNIT F11BE FA UNIT F11ME 13 3 Installing the Motherboard Installing an expansion board Various types of boards can be installed in the expansion slot However any of them can be installed following the same procedures Preparation 1 Turn the power switch off 2 Pull the power plug of the unit from the wall outlet Insertion of expansion board 1 Remove the screws fastening the top cover then remove the cover When loosening the screws use the appropriate type of screwdriver that fits the screw head CONTEC 14 FA UNIT F11BE FA UNIT F11ME 3 Installing the Motherboard 3 Install the expansion board and fix it with screws 4 Return the fall off prevention bar and cover to their original positions and fix them with screws Unplugging an Expansion Board To unplug an expansion board follow the steps below in the reverse order of plugging it 1 Before starting removing the expansion board pull the power plug of the unit from the wall outlet 2 Following the same procedures as for insertion remove the bracket fixing screws of the slot from which you want to remove the board 3 Remove the board by pulling it at a right angle to the expansion slot 4 Use the screw to fasten the bracket removed when plugging the board 5 Replace and screw the cover CONTEC FA UNIT F11BE FA UNIT F11ME
14. n M3 x 6 25 Screws for HDD 6 32UNC x 5 8 Hexagon spacer 13 x4 S xg Rubber pads Screws for HDD Pd i Plastic Spacers 8 0 Screws for Rubber pads Hexagon spacer Chassis Power cable x25 Screws used for expansion bay fixing and board installation User s Manual x4 aS x2 Slot cover Bracket for wall mounted User s Manual Copyright Copyright 2005 CONTEC CO LTD ALL RIGHTS RESERVED No part of this document may be copied or reproduced in any form by any means without prior written consent of CONTEC CO LTD CONTEC CO LTD makes no commitment to update or keep current the information contained in this document The information in this document is subject to change without notice All relevant issues have been considered in the preparation of this document Should you notice an omission or any questionable item in this document please feel free to notify CONTEC CO LTD Regardless of the foregoing statement CONTEC assumes no responsibility for any errors that may appear in this document or for results obtained by the user as a result of using this product Trademarks Other brand and product names are trademarks of their respective holder CONTEC ii FA UNIT F11BE FA UNIT F11ME Table of Contents Check Your Package esnjsulam ii Trademarks 5 35 rr pac c eae a RE EE ii
15. nd two USB connectors on the front surface of the case Depending on the combination of the backplane SBC and expansion board mounted on FA UNIT F11BE one of the two installable 3 5 inch drives may not be installed For details contact our general information center CONTEC FA UNIT F11BE FA UNIT F11ME 1 1 Before Using the Product Option Installable backplanes BPI 1111 PICMG Backplane with 10 Slots PICMG x 2 PCI x 4 ISA x 4 BPM 1111 PICMG Backplane with 11 Slots PICMG x 2 PCI x 8 ISA x 1 BPC 1111 PCI Backplane with 10 Slots PCI x 10 Other FA CLAMP 01 Clamp for PCI ISA board 5 pcs Check the CONTEC s Web site for more information on these options Available Replaceable Parts for Maintenance POW300X 300W ATX Power Supply FAN1225S Fan 120 x 25 with Sensor FANO825S Fan 80 x 25 with Sensor FLTI2I Fan Filter 127 x 127 CONTEC 2 FA UNIT F11BE FA UNIT F11ME 1 Before Using the Product Customer Support CONTEC provides the following support services for you to use CONTEC products more efficiently and comfortably Web Site Japanese _http www contec co jp English http www contec com Chinese http www contec com cn Latest product information CONTEC provides up to date information on products CONTEC also provides product manuals and various technical documents in the PDF Free download You can download updated driver software and differential files as well as
16. re using the product About the Chassis FA UNIT F11BE is a chassis used to mount a backplane and SBC and configure a computer system in combination with expansion boards and various drives FA UNIT F11ME is a chassis used to mount a motherboard and configure a computer system in combination with expansion boards and various drives Features FA UNIT FI1BE A PICMG compliant PCI bus or ISA bus backplane can be mounted FA UNIT F11ME An Micro ATX motherboard can be mounted Common Equipped with 5 inch drive bay x 2 and 3 5 inch drive bay x 2 Equipped with a power switch reset switch and USB connectors at the front Equipped with a built in cooling fan The dustproof filter and cooling fan can be replaced externally These fans can easily be replaced externally without removing the top cover A chassis fixing bracket is attached as standard Configuration Backplanes and mother boards are sold separately You need prepare a CONTEC backplane corresponding to this product separately For more details of the corresponding backplanes see Option When using a third party s backplane or motherboard pay attention to the positions of the backplane or motherboard installation holes installable size and power supply specifications of this product This product has a space that can contain two 5 inch drives and two 3 5 inch drives It also has a power ON OFF switch power supply LED HDD access LED reset switch a
17. seseseseeeceeesseseesseetseseseeeseesseseeaeaee 13 Installing am expansion board ise eate ree eee era 14 14 FA UNIT F11BE FA UNIT F11ME iii Insertion of expansion board sese ennt nente enne tete A 14 Unplugging an Expansion Board enenne nenne rennen 15 Replacing th connector plate oreet tete ert det eee Rete dee peret d eee eri 16 Installing Disk Drives ane bee e e PRESSES ERU 17 Preparation UTR RERUMS eee ERR ANNETTE Ee PUn 17 Installing Disk Drives ect ea ER bee PER GB RR ecco 17 Installing Removing a fan and filterset certe tntetice re tesa e d retirer epa 18 Installation conditions ees e EH ER ER RR LR PAREN onde etg 19 Installing the wall mount bracket eee e HERES PER EA IEEE RESET Ea 20 4 CONNECTORS 21 Power Supply etie YR REND MEER a 21 Backplane or motherboard power supply connectors eese 21 HDD FDD power supply connectors eese A 21 Switches and LEDS seese sirves aE 22 USB EBan SEKO e E A T T E 23 5 SYSTEM REFERENCE 25 Specification oce e Ure derit e 25 FA UNIT F11BE FA UNIT F11ME 1 Before Using the Product 1 Before Using the Product This chapter provides information you should know befo
18. talling or removing an interface board into from an expansion slot be sure to remove the cable from the AC inlet The total power consumption by the boards installed in expansion slots must not exceed the rating If the product becomes dirty wipe it carefully with a soft cloth damped with water or a solution of neutral detergent Keep in mind that using a volatile solvent such as benzine or thinner or a chemical can deform or discolor the surface of this product When performing maintenance of boards and electrical system components be sure to remove the cable from the AC inlet The installable power supply is one that can be used in industrial environments where spike voltage of 1 5kV or so is generated If spike overvoltage higher than this voltage is generated protective actions may be required The specifications of this product are subject to change without notice for enhancement and quality improvement Even when using the product continuously be sure to read the manual and understand the contents Do not modify the product CONTEC will bear no responsibility for any problems etc resulting from modifying this product Regardless of the foregoing statements CONTEC is not liable for any damages whatsoever including damages for loss of business profits arising out of the use or inability to use this CONTEC product or the information contained herein FA UNIT F11BE FA UNIT F11ME 5 1 Before Using t
19. ure 2 1 Front Side View Rear Side View Connector plate r ale C p iil same 0000005 Figure 2 2 Rear Side View of FA UNIT F11BE FAN cover Connector plate Figure 2 3 Rear Side View of FA UNIT F11ME CONTEC FA UNIT F11BE FA UNIT F11ME 2 Name of Each Part and Dimensions Diagram Dimensions FA UNIT F11BE Q000000000000000 T po E m m eoo NO Sie T e m rt 2 oo i 845 Ill 380 396 364 n et lo Br mm Figure 2 4 Dimensions lt FA UNIT F11BE Horizontally placed gt CONTEC FA UNIT F11BE FA UNIT F11ME 2 Name of Each Part and Dimensions Diagram R4 5 R2 5 Ng 193 209 15 130 130 845 _6 166 80 420 177 364 I 000 1000000100 mm Figure 2 5 Dimensions lt FA UNIT F11BE Vertically placed gt FA UNIT F11BE FA UNIT F11ME 2 Name of Each Part and Dimensions Diagram
20. ut prior written consent of CONTEC CO LTD 11022006 09012005 Management No 51 066 11022006 rev5 Parts No LYFB623
21. warrantor be liable for any incidental or consequential damages due to such defect or consequences that arise from inexperienced usage misuse or malfunction of this device FA UNIT F11BE FA UNIT F11ME 3 1 Before Using the Product Safety Precautions Understand the following definitions and precautions to use the product safely Safety Information This document provides safety information using the following symbols to prevent accidents resulting in injury or death and the destruction of equipment and resources Understand the meanings of these labels to operate the equipment safely DANGER DANGER indicates an imminently hazardous situation which if not avoided will result in death or serious injury WARNING WARNING indicates a potentially hazardous situation which if not avoided could result in death or serious injury CAUTION CAUTION indicates a potentially hazardous situation which if not avoided may result in minor or moderate injury or in property damage FCC PART 15 Class A Notice NOTE This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in
Download Pdf Manuals
Related Search
Related Contents
PiggyBac Transposon Vector System User Manual Samsung VC-6111 Инструкция по использованию manual de instrucciones CONDUCTIVIMETRO PORTATIL HI 8733 No 06 Partenariat Ecole-Famille manuel d`installation, utilisation et entretien four encastrable 30` User Manual - Pro Lighting Manual NWCHEMRATE – version 2007 Dataram 16GB(2 x 8GB) DDR3-1066 ENGLISH - Shopatron Copyright © All rights reserved.