Air Circuit Breakers (250A – 6300A)

image

Contents

1. n case of double rating of rated voltage it is the value to the lower rating Example In case of DC 24 to 48 it is operating time to DC 24 V The closing coil is a device to close the breaker 2 Closing time is from the initial energization of the closing coil to the completion of the closing of the main contacts As CC is one pulse driven it is not necessary to insert AXb for burning prevention pur poses Inserting AXb will cause anti pumping function to be ineffective CC AD250 W 100 250 AC DC LS 100 250 0 7 1 7 AC100V 100 VA AC 250V 200 VA DC 100 V 100 W DC 250 V 200 W max 0 08 or less 0 8 1 8 168520 s MITSUBISHI ELECTRIC SAE Accessories B Shunt trip device SHT The shunt trip device is used to open the breaker by remote control A cut off switch is included AX HAX NJ Specifications SHT D048 W SHT A500 W SHT AD250 W Rated voltage V 24 48 DC 380 500 AC 100 250 AC DC Applicable voltage range V 16 8 52 8 266 550 70 275 A Operating voltage V 24 48 380 500 100 250 AC 0 5 0 7 AC380V250VA 0 4 1 4 AC100V100 VA 2 Inrush current AC 500 V 300VA AC 250 V 150 VA w peak value pca 25 60 DC24V100W 0 6 1 6 DC 100V 100W DC 48 V 200 W DC 250 V 200 W Closing time sec max 0 04 or less max 0 04 or less max 0 04 or less E ua Breaker Cut off switch Order information Art no 1
2. Shipping contents AE1000 SW AE1000 SW 3P Fix ETRBASE P3 AX10 168373 AE1000 SW 4P Fix ETRBASE P3 AX10 168434 Electronic trip Relay base unit Power supply PW3 AE1250 SW AE1250 SW 3P Fix ETRBASE P3 AX10 168435 AE1250 SW 4P Fix ETRBASE P3 AX10 168436 10 auxiliary contacts 5 NO 5 NC contacts Automatic reset type trip coil TCA AL W 168438 168444 168446 168448 Further elements that must be ordered Main setting module for protection O Accessories as required Cradle with the drawout mechanism SV ao CRD163 W Draw Out type AE1000 AE1600 3P 170078 Air circuit breaker series AE SWA Shipping contents AE2000 SWA AE2000 SWA 3P Fix ETRBASE P3 AX10 168439 AE2000 SWA 3P D O ETRBASE P3 AX10 168441 e aaa AE2000 SWA AE2000 SWA 4P Fix ETRBASE P3 AX10 168440 AE2000 SWA 4P D O ETRBASE P3 AX10 168442 10 auxiliary contacts 5 NO 5 NC contacts Automatic reset type trip coil TCA AL W 168451 168452 AE4000 SWA AE4000 SWA 3P Fix ETRBASE P3 AX10 168449 AE4000 SWA AE4000 SWA 4P Fix ETRBASE P3 AX10 168450 AE4000 SWA 3P D O ETRBASE P3 AX10 AE4000 SWA 4P D O ETRBASE P3 AX10 Further elements that must be ordered O Main setting module for protection O Accessories as required Air circuit breaker series AE4000 6300 SW Fixed Drawout type Base unit equipment Breaker Fixed type 3 4 pole Art no Draw out type 3 4 pole Shipping content
3. O O O sa e nel EGNER Pa EM ee EO NAP ow eee Of OY o e o O eo O O can be displayed by DP1 DP2 Display module Extension module VT W unit X1 0P1 P2V1 w WS WM APA Ge FEE NP RAP AGE P3 P5 O O Q O O O O 3 5 19th O O O O O Q 9 O 0 O Q O Q O e O O O OF 9 O Q Qo e Q o e O O OG can be displayed and set by DP1 DP2 s MITSUBISHI ELECTRIC
4. Base Units Overview and mounting positions of the main accessories SAE Accessories Eu Page13 Auxiliary switch Page 13 CNT Counter UVT Page 12 Under voltage trip device Page 14 SHT EUM Page 15 SST Shunt trip device Mis insertion preventer Safety shutters Closing coil Cell switch LE S91J0SS920y JYS Lifting hooks EUM Page 11 Motor charging device UVT Page 12 Under voltage trip device CYL CAL Page 14 Cylinder lock Castell lock optional Electronic trip relay Drawout mechanism with drawout handle Power supply Aa MITSUBISHI ELECTRIC 10 Overview and description on the optional accessories E Motor charging device MD Specifications MD AD125 W Rated voltage 100 125 V AC DC Applicable voltage range EM 85 137 5 Applied voltage V 100 125 Inrush current peak value A 10 12 Steady current A 3 Charging time sec lt 5 Criterion for power require None VA 700 1000 Order information Art no 168514 Bi Trip coil AL SX MITSUBISHI ELECTRIC MD AD250 W 200 250 AC DC 100 125 V AC DC 200 250 V AC DC 170 275 85 137 5 170 275 200 250 100 125 200 250 10 12 5 6 n 7 8 4 2 lt 5 lt 5 lt 5 700 1000 700 1000 700 1000 1
5. and the operating sequence to be checked Order information Art no 168977 3 m length of cable is equipped as standard j D Other length t Other lengths available on request er lengths on reques W Interphase barriers Connections AE1000 SW AE1600 SW AE2000 SWA AE2000 SW AE3200 SW AE4000 SWA Horizontal FIX Qo x Q x Fixed Vertical terminal FIX VT X A x A type Vertical terminal adaptor VTA A x A x Front terminal adaptor FIX FTA A X A X Horizontal DR x o x Vertical terminal DR VT e A A A penge Front terminal DR FT x A x Vertical terminal adaptor VTA A x A x Front terminal adaptor DR FTA A X A X Available for the insulation A Available for separating terminals X lt Not existing type Attachment is impossible For AE4000 SW to AE6300 SW not available ata MITSUBISHI ELECTRIC 19 NJ SAE Accessories SAE Electronic Trip Relay E SAE Electronic Trip Relay Introduction and selection RUN LED ERR LED standard This indicator displays the ETR situation Run or Error Pre alarm PAL standard This indicator displays the Pre alarm situa Load current LED standard This indicator displays the ETR situation Run or Error Power supply module tion when the setting current exceeds If a power supply module with alarm contacts is installed the output contact of Pre alarm is available The output is reset when the electric cur
6. 3200 4000 2000 4000 h 2500 5000 h 3150 6300 h 80 80 80 80 80 80 80 1500 1500 1000 500 1000 1000 1000 1500 1500 1000 1000 1000 1000 s 5 s O O O O O O O 410 x 475 x 290 414 x 8 3 x 290 410 x 605 x 290 414 x 1003 1133 x 290 O 180 Se 180 5 180 5 o n m9 m5 55 nm m mm 0308 n6 n no m6 898 22099 3099 9099 35 119 35 140 35 49 118 118 125 43 44 43 61 43 61 133 148 133 148 140 155 This value means the instantaneous breaking time at short circuit interruption As for accessories SHT UVT refer to page 12 and 13 D 4 HN means the neutral poles current capacity is 50 of the rated current for 4 poles 4 FN means the neutral poles current capacity is 10096 of the rated current for 4 poles shows the value for 4P FN type Remarks All models conform the isolating function according to IEC 60947 2 Reverse connection is possible ata MITSUBISHI ELECTRIC 7 SAE Base Units Connections Connection arrangements The following connecting methods are available for the AE1000 SW AE3200 SW m Connection Horizontal connection Vertical connection Front connection Vertical terminal adapter Front terminal adapter Mounting method Standard Optional Optional Accessory Optional gt qp N cS ca T Fixed type WY Standard FIX FTA Drawout type Standard DR VT DR FT DR VTA DR FTA Standard equipment S
7. AE4000 SW i EEE 9 A TOS a 150 10 8 6 4 2 2 4 6 8 10 x Ir AE6300 SW WM3 INST MCR WM3 10 INST Pre alarm current Ip lux0 68 1 0 0 04 step OVER 5 OVER Pre alarm time Tp 1 2TL after 1 2 TL PAL contact output turns on 20 Upper figure and table include optional MCR function O Pre alarm current OVER setting is equal to 1 0 Specifications WM1 W WM2 W WM3 W Main setting Module S type WM1 WM2 WM3 Order information Art no 168552 168553 205180 Note WB type for special use is available on request ata MITSUBISHI ELECTRIC 25 SAE Electronic Trip Relay E Ground fault protection GFR The ground fault protection GFR of several Specifications G1 W hundred amperes is possible Optional setting Module G1 Ground fault protection This function can be selected for trip and alarm module no trip Power supply is necessary for this func tion even if there is not power supply it can function at 0 2 x In or higher Order information Art no 168558 Setting item Adjustable setting range Accuracy Setting for shipment GFR pick up current lg 0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 0 9 1 0 x In 20 1 0 3 1 5 0 8 0 5 0 3 0 15 0 1 0 1 0 15 0 3 0 5 0 8 1 5 3 s at 1 5 x lg GFR time Tg TRIP ALARM 20 3 s TRIP SAE Electronic Trip Relay E B 2nd Additional Pre alarm AP The Pre Alarm 1st function already installed Specificat
8. In case of BIF PR 1 contact monitoring is available Breaker drawout position Position CONNECTED TEST and DISCONNECTED BIF CL is required Specifications BIF CON W Application 0 unit network module Order information Art no 168574 SAE Electronic Trip Relay Tm SAE Electronic Trip Relay Configuration table of ETR with EX1 and VT W module Combination sample Type Main setting module Optional setting module Power supply Load current 2 5 Leakage current 15 3 Voltage 2 5 Power active reactive apparent 2 5 Power factor 5 Energy active reactive 2 5 96 Harmonics current 2 5 Frequency 2 5 LTD STD INST GFR ER UVT PAL1 PAL2 OVER GFR EPAL ER LTD STD INST PAL1 PAL2 GFR EPAL ER Output contacts setting change Date amp Time Demand time Alarm holding method Trip and alarm information Measurement information min and max values Main Optional setting module information Error information CT rating Phase line method Normal connection or reverse connection 2 units of display modules can be attached Display is available only when UVT module is attached 9 Included the accuracy of ZCT 30 NP Display module Extension module Q E WS P G OJO ee D 9 0 WM E1 NP AP G1 E1 NP P3 P5 O Hee O O ne yee Boe Opa pee ee Oe C hon REST aa EE ETE NE TEC aa COMER OS OS
9. Y 2000 optional and push this reset but ton as a result of LTD and STD function become ineffective Aa MITSUBISHI ELECTRIC SAE Electronic Trip Relay Standard functions B OCR alarm AL When it happens to trip by over current ground fault GFR or Earth leakage ER this function issues a warning alarm HM Neutral pole overcurrent protection NP When harmonics in load current are large the Neutral pole overcurrent protection prevents current on neutral pole exceeding rated current them by operating at 100 of rated current may flow Harmonics may cause some troubles on neutral pole Please see page 27 for 50 neutral protection Special functions optional E MCR Making current release Just under the breaker closing operation from When you order the MCR switch MCR switch is open to close Instantaneous characteristic built in the main body If MCR switch is built in become effective but after closing the breaker the main body and the adjust dial of INST MCR instantaneous characteristic become ineffective on main setting module is set the MCR position MCR function become effective see page 27 E NCT Neutral CT is required for Ground fault or Neu tral pole protection when 3 pole breaker is used for 3 phase 4 wires system see page 18 B ZCT ZCT is required for a few amperes earth leakage protection and is combining ER plug see page 18 aa MITSUBISHI ELECTRIC 21 SAE Electronic T
10. careless touch ing to the live control terminals The TTC F W is included within the delivery of a fixed type AE SW as standard The door frame improves the appearance after cutting out the panel door to install the breaker Details on request SAE Accessories Specifications BCL W Material Acrylic plate Order information Art no 168537 NJ SAE Accessories Specifications DUC W Material IP 54 Order information Art no 168960 Specifications TIC F W vo Dawout Fixed Application breaker type type Protection IP 20 IP 20 M n 168972 Order information Art no 168549 Standard Specifications DUC W Application Breaker For all breakers Material Plastic Protection IP 20 Order information Art no 168960 17 2 SAE Accessories SAE Accessories B Current transformer CT These current transformers CT and sensor coil Current transformers of type CT 06 ULIL serve are suitable for the main conductor and the N the reduction of ly max on an AE1000 conductor CT 06 W CT 060W CT06W CT 06 W CT 10 W CT12 W CT16eW CT20 W CT 20 W CT 20 W iq EE Specifications 025 031 050 063 100 125 160 125 160 200 250 320 Application breaker AE1000 SW AE1000 SW AE1000 SW AE1000 SW AE1000 SW AE1250 SW AE1600 SW AE2000 SW AE2000 SW AE2000 SW AE2500 SW AE3200 SW Rated current IN max O A 250 315 500 630 1000 1250 1600 1250 1600 2000 2500 3200 Order information Art no 193939
11. delay on 3 Qa A J p OO EM OS ac CNN 1 Q 0 CX o D DELL INT Qut3 D1 a C UVT controller 3 3 mr UVT controller Le D2 a Trip button l IN2 OUT4 D2 w m a i eee z XY OT WTcoil Tipcontatt mm DTi UVT coil lt DT2L min 0 2 sec 5 max 2m Breaker max 2 m Breaker LLI pre ot AOE EEA IAEA T E E EE PT Cray rer carers Uae GN ENE lt L A UCON UCON UCON UCON UCON UCON UCON UCON Specifications D024B W INST D048B W INST D110B W INST D125B W INST D250B W INST A120B W INST A240B W INST A460B W INST Rated voltage V 24 DC 48 DC 100 110 DC 120 125 DC 220 250 DC 100 120 AC 200 240 AC 380 460 AC Frequency 50 60 Hz Operating time time delay INST 0 2 sec 10 25 sec 10 5 sec LI 0 8 sec L 1 0 sec L 1 5 sec 13 0 sec Pick up voltage V 15 6 20 4 31 2 40 8 65 85 78 102 143 187 65 85 130 170 247 323 Drop out voltage V 10 8 16 8 21 6 33 6 45 70 54 84 99 154 45 70 90 140 171 260 Trip function With open circuit of DT1 DT2 terminals Power consumption VA 20 Order information Art no 203341 203342 203343 203344 203345 203346 203347 203348 Accessor
12. on 20 Upper figure and table include optional MCR function O Pre alarm current OVER setting is equal to 1 0 Specifications WS1 W WS2 W WS3 W Main setting Module S type WS1 WS2 WS3 Order information Art no 168552 168553 205180 24 a MITSUBISHI ELECTRIC SAE Electronic Trip Relay M Types Generator Protection Load current LEDs Rated current Ir Q INST MCR pick up adjusted and labelled by factory Fixed current li setting dial MCR option 9 TYPE WM1 Q LTD pick up current IL setting dial RUN LED ERR LED Pre alarm LED LTD time Ti setting dial SAE Electronic Trip Relay Loo 2 It 05 rt on Tsd s orr Q STD time Tsa setting dial Trip indicator LEDs Q STD pick up current Isa setting dial LSD Adjustable setting range Setting item Adjustable setting range Accuracy Setting for shipment Current setting lr 0 63 1 0 x In Adjust by factory Fixed Specify when ordering e ULTD pick up current IE 1 0 1 05 1 1 1 15 1 2 x Ir 5 1 0 O LTD time TL 115 20 25 30 40 60s atlLx 12 20 150 6 STD pick up current lsd 1 5 2 2 5 3 3 5 4 4 5 5 x Ir 15 10 0 5 0 4 0 3 0 2 0 1 0 06 0 06 0 1 0 2 0 3 0 4 0 5 s 20 12 t ON I2 t OFF This means it operates in the range 2 VE ie between 0 04 and 0 08 s when the o en at Isd x 1 5 time set at 0 06 s AE1000 SW AE1600 SW AE2000 SW AE3200 SW wM se ONE WM1 16 INST TERRE
13. rent goes below the set level after an alarm is set off 20 Trip indicator LED standard This indicator displays the trip cause TEST terminal standard This terminal already installed as standard and is used for checking by the field test device Y 2000 This module provides control source for Display module Trip indicator and several indicators LEDs Even when the control power source is off the function of over current protection and ground fault protection are effective The power supply modules provide 6 output contacts for external use see page 22 Pre alarm current level setting dial standard For setting the current level for Pre Alarm If current exceeds this level pre alarm is indicated Display Several measuring data current voltage power etc and alarms can be displayed with this module see page 28 Main setting module This module provides the function of over current protection It is possible to select the two setting modules according to application see page 24 Neutral protection of rated current 100 function is standard at 4 pole breaker Optional setting module option figure shows G1 Additional functions and character istics can be selected by optional setting modules see page 26 RESET button standard When push this reset button trip indica tor and Pre Alarm will be reset And when the instantaneous test by field test device
14. 168538 MITSUBISHI ELECTRIC 13 2 SAE Accessories SAE Accessories Bl Cell switch CL ll Safety shutters SST 14 The cell switches can be set for all the Switch function Disconnected Connected relevant positions i e connected test and Disconnected Test Operation disconnected J g l J Each cell switch consists of 4 individual switches CONNECTED CL C TEST EE CET DISCONNECTED CL D Specifications BIF CL W Load Resistive Inductive Resistive Inductive AC 460 V 5 25 5 25 AC 250 V 10 10 10 10 Contact capacity A BIN M i 18 W DC 250 V 3 1 5 3 1 5 DC 125 V 10 6 10 6 DC 30V 10 10 10 10 Maximum contacts Total 4c Order information Art no 168512 168575 D BIF CL only necessary for networks operation The interlock device locks the circuit breaker into the OFF position There are two locking options available e Cylinder lock CYL Castell lock CAL a The relevant key can only be taken out in the OFF position of the circuit breaker so that it can also be used for unlocking other breakers Specifications CYL WK W CYEWKi N CYE WI2 W CYL WK3 W CYL WK4 W CYL NK W Interlock Cylinder Cylinder Cylinder Cylinder Cylinder Castell Closing Basic 1 2 3 4 Basic Order information Art no 168539 168540 168541 168542 168543 168544 The closing basis for the Castell lock can be designed individually Further details on request The safety shutters cov
15. 193940 193941 193942 193943 193944 193945 193946 193947 193948 193949 193950 Shipping contents includs CT and sensor coil for 1 pole Other transformers on request At40 Cand 50 60 Hz B Neutral current transformer NCT Block diagram with NCT function ACB The neutral CT is used for ground fault protec tion when a 3 pole breaker is used on a 3 phase 4 wire system The Ground fault protection module type G1 should be used as optional setting module Control supply Specifications Application breaker AE630 SW AEIO00 SW EDO GETOUW AEZOOOSWA AESQ SW A3200 SW AE4000 SWA Current range A 630 1000 1250 1600 2000 2500 3200 4000 Order information Art no 168986 168987 168988 168989 168990 168991 168992 168993 External current transformer ZCT ZT Transformer ground wire method ZCT AB This option is used to detect several amperes EE 1 of earth leakage when used in combination i De pu with an electronic trip relay that has the earth d leakage tripping ER option Two methods are available e ZCT three load phase conductors and the neutral conductor in a 4 wire system are Control passed through the ZCT Alarm supply amp ZT The other method uses a smaller ZCT contact TT 7 7 contact TT TT TT only supply transformer ground wire passes output output through to earth Specifications ZCT 163 W ZCT 323 W ZCT 324 W Z1 15B W ZT 30B W ZT 40B W ZT 60B W ZT 80B W ZT 100
16. 68515 168516 168517 In addition to manual operation the closing spring can be charged automatically by an electric motor every time the breaker is closed ON charging method If the closing spring is to be charged automati cally whenever the breaker is opened then this can be done through an additional auxiliary contact AXb OFF charging method As soon as charging is completed a visual display on the front says CHARGED The CHARGED signal is also available via the 413 TS and 414 TS terminals included in the standard MD configuration MD AD125 4A4W W Automatic reset type TCA AL W OCR alarm AL is provided as standard if ETR is equipped OCR alarm AL is the contact 1a of short time operation 30 ms being output when the breaker is tripped by the electronic trip relay Two types of automatic reset type standard and manual reset type optional are available When ordering specify either Specifications TCA AL W S AC V 125 240 3 DC V 30 125 240 AM AC A 5 3 Resistive load a aged DCA 4 04 02 AC A 3 2 Inductive load eae ee DC A 3 04 02 Order information Art no 168535 standard Notes MD AD250 4A4W W SAE Accessories There is always the option of manual operation in an emergency A closing coil CC is required for closing the breaker by remote control and a shunt trip device SHT is required for opening it in this way This warrants the prevention of pump
17. 68524 168523 168522 Min 40ms P st piger SHT unit n case of double rating of rated voltage it is the value to the lower rating Hk VG Example In case of DC 24 to 48 it is operating time to DC 24 V Control supply l y l l I i Diode rectifier is not used for control source 24 48 V DC Bl Auxiliary switch AX HAX on IX p This is the contact that is used to remotely indi The chattering time at the time of contact mane Er cate the ON or OFF status of the breaker ON OFF is below 0 025 sec PA gt 4 Eu Ji For special environment specification the The a and b contacts may turn simultane contact capacity gets deteriorated Apply for ously to ON instantaneously at the time of further detail changing the contact Pay attention to the contact state when designing circuits Specifications HAX 10 W Load Resistance Inductive Resistance Inductive AC460V 5 2 5 2s AC250V 10 10 10 10 Contact capacity A 10 IS Is E DC250V 0 3 0 3 3 15 DC125V 0 6 0 6 10 6 DC30V 10 6 10 10 Maximum number of contacts 5a5b 5a5b Order information Art no 168962 standard 168961 B Counter CNT This is a mechanical counter which registers the Specifications CNT W total number of operating cycles with 1 ON dA Counter type Mechanical OFF switching operation 1 operating cycle Display 5 digits The number of operating cycles is displayed on the front of the unit Order information Art no
18. B W Application Load circuits Transformer ground wire Hole diameter for wire mm 230x60 oval 370x108 oval 500x108 oval 15 30 40 60 80 100 Order information Art no 168994 168995 168996 168997 168998 168999 169000 169001 169002 Further details on request 18 Aa MITSUBISHI ELECTRIC SAE Accessories Bi Internal power supply units PW These power supplies are used for supplying The PW3 W is included as standard power sup the ETR base unit They are equipped with 6 ply in the ACB s outputs alarms and errors Specifications PW3 W PW4 W PW5 W 100 240 AC S 2 Power supply V 100 125 DC 24 60 DC 100 240 DC Output contacts 6 6 6 SSR Order information Art no 168985 standard 168562 168563 The electronic trip relay can be checked by this field test device when the breaker is at test or disconnect position So it allows you to test the trip relay without the breaker being connected to the main supply The breaker will trip when tested Specifications Y 2000 Power supply 100 240 V AC 50 60 Hz Test functions LTD INST STD Ground fault pre alarm Test current signal setting Continuously variable 10 2500 96 Others Ammeter time counter Order information Art no 27496 ll Test jumper TJ With the breaker taken out of its cradle this Specifications Test Jumper device enables the breaker to be electrically Cable length m 30 opened and closed
19. Low Voltage Switchgears I Air Circuit Breakers GE EEE ENE MN 4 NN 10 3 Bectronic Top Relay iisossus su AS SEE EEDESRMRRIBANRRRRRER RS RAAENEECEGESENRRRARRSERRAERER ANAMEMSUAEEEN 20 S MITSUBISHI ELECTRIC EF EJ oh G f 6 bi SAE Base Units Product Skeleton of Accessories for SUPER AE Series Air Circuit Breakers Mitsubishi Electric offers a wide range of acces sories for the Air Circuit Breakers to serve almost all variations of applications N I2 aB N S ca Lu lt L VN e n La ml Position Name 1 Air circuit breaker 12 Dust cover DUC 23 Counter CNT 2 Cradle 13 Push button cover BC L 24 Cylinder lock CYL 3 CC Link Interface unit 14 Auxiliary switch standard AX 25 Door interlock DI 4 PROFIBUS DP Interface unit 15 Auxiliary switch high capacity type HAX 26 Mechanical interlock MI 5 MODBUS Interface unit 16 Shunt trip device SHT 27 Safety shutters SST 6 1 0 unit 17 Closing coil CC 28 Safety shutter lock SST LOCK 7 Extension module 18 Under voltage trip device UVT 29 Cell switch CL 8 ETR unit 19 Trip coil TC OCR Alarm 30 Interphase Barrier BA 9 Main setting module 20 UVT controller U CON 31 Horizontal terminal 10 Optional setting module 21 Condenser trip device COT 32 Vertical terminal 11 Door frame DF 22 Motor charging device MD 4 a MITSUBISHI ELECTRIC SAE Base Units Product Introduction of Accessories
20. SUPER SERIES Breaker type 1000 1250 1600 2000 1000 690 12 3 1250 1600 2000 400 lt Ir lt 1000 800 lt Ir lt 1250 1000 lt Ir lt 1600 1250 lt Ir lt 2000 1000 1250 1600 2000 65 65 65 65 65 65 65 65 250 250 250 250 250 250 250 250 143 143 143 143 143 143 143 143 143 143 143 143 52 5 525 52 5 52 9 52 5 525 525 525 O O O 40 400 400 40 80 80 80 80 5000 5000 5000 1500 5000 5000 5000 1500 O O O O O 410 x 340 x 290 410 x 425 x 290 O O The columns for without instantaneous are the values when the bare main body and the external relay is combined The number of operating cycles without rated current also include the number of operating cycles with rated current G AE4000 SW AE5000 SW AE6300 SW AE2000 SWA and AE4000 SWA apply for only vertical terminal of connecting terminal This value means number of operating cycles of ACB s body not including accessories Products with low rating types is available SX MITSUBISHI ELECTRIC Ov SAE Base Units nezooo sw a2500 Sw AE3200 SW AE4000 SVA AE 4000 5 ET AE 6300 5 2000 2500 3200 4000 4000 5000 6300 1000 1000 690 690 A 4 12 12 3 3 N ca MPAs EE see EEE Ss 2000 2500 3200 4000 4000 5000 6300 LLI WY 800 lt Ir lt 2000 1600 lt Ir lt 2500 2000 Ir 3200 2500 lt Ir lt 4000 2500 lt Ir lt 4000 3150 lt Ir lt 5000 4000 lt Ir lt 6300 2000 2500
21. dapter VTA power connection by 90 AE5000 SW and AE6300 SW models vertical ar Vertical terminal adapters allow you to turn For AE2000 SWA AE4000 SWA AE4000 SW terminal only is available Specifications VTA 02 W VTA 03 W VTA 32 W Application breaker AE1000 AE1600 SW AE2000 2500 SW AE3200 SW Shipping contents pieces 1 1 1 Order information Art no 168978 168979 168980 Front terminal adapters FTA allows a vertical con nection for supply and load busbars FTA FTA FTA FTA FTA FTA FTA FTA FTA FTA FTA 164F W 253F W 254F W 323F W 324F W 163D W 164D W 253D W 254D W 323D W 324D W AE1000 AE1000 AE2000 AE2000 AE1000 AE1000 AE2000 AE2000 AE1600 SW AE1600 SW AE2500 SW AE2500 SW AE1600 SW AE1600 SW AE2500 SW AE2500 SW Specifications Application breaker AE3200 SW AE3200 SW AE3200 SW AE3200 SW Pole 3 4 3 4 3 4 3 4 3 4 3 4 Typ Fixed Drawout Shipping contents pieces 6 8 6 8 6 8 6 8 6 8 6 81 Order information Art no 169331 169332 169333 169334 169335 169336 169337 169338 169339 169340 169341 169342 ata MITSUBISHI ELECTRIC 15 2 SAE Accessories SAE Accessories B Mechanical interlock MI Horizontal mounting This is the device to prevent parallel charge of 2 or 3 units of breakers and it can interlock the breakers mechanically without fail All combinations are available among any models from AE1000 SW t
22. er the main conduc tors of the cradle side supply and load side automatically when the circuit breaker is drawn out The safety shutters can also be locked with a mechanical locking device SST LOCK The padlocks have to be supplied by customer When checking the main circuit the safety shutters on the supply and load sides can be opened independently of one another Specifications SST LOCK W SST 203 W SST 204 W SST 403 W SST 404 W Breaker type Drawout Number of poles 3 4 3 4 B 4 Order information Art no 168510 168973 168974 168975 168976 s MITSUBISHI ELECTRIC SAE Accessories E Vertical terminal adapter VTA To obtain the right draw out configuration it is extremely important that the breaker unit Material Metal specifications type current rating optional accessories etc should match the cradle Orderintounation rtno 168547 Mis insertion is prevented by a combination of matching components on the breaker and the cradle NI E Shorting b contact SBC When moving the breaker from the connected to the test positions this contact is used to short circuit auxiliary switch Axb thus maintaining the correct sequence of operation of the external control circuit SAE Accessories Specifications SBC 1 W SBC 2 W SBC 3 W SBC 4 W Number of contacts 1 2 3 4 5 Application breaker All breakers Order information Art no 168548 202337 202338 202339 202340 ll Vertical terminal a
23. ers energies harmonic currents and etc by connecting the ETR with Extension module EX1 MITSUBISHI Unit for Order information Art no 168567 28 It is to be placed separatetly outside the the breaker A connection cable of 2 meters length is included Specifications VT W U P E cos phi earth leakage average measuring trip history trip current measuring sa MITSUBISHI ELECTRIC SAE Electronic Trip Relay B Interface unit BIF CC BIF PR BIF MD MITSUBISHI POWER MITSUBISHI POWER TERR e BF BUSADDRESS RESET EEGEEEGEI ON ean MITSUBISHI POWER O RXD OTXD sw Modbus TERR Mou ADDRESS c pue JEEE x amp c B 1 0 unit BIF CON BIF CL MITSUBISHI AIR CIRCUIT BREAKER I O UNIT MODEL BIF CON POWER F esu INPUT e cc INPUT2 REMOTE e MD INPUT3 LOCAL ata MITSUBUSHI ELECTRIC CORPORATION SX MITSUBISHI ELECTRIC These Interface units can expand the future 9 Intelligent control by Multi data commu possibility in various communication and Intel nication ligent controla It comes into being the Intelligent control by Multi data communication through these Applicable to various open networks interface units to PLC SCADA which transfer the measurement information setting values err
24. for SUPER AE Series Air Circuit Breakers AE1000 SW IEC 60947 2 Drawout type Cell switch Auxiliary switch AE1250 SW EN 60947 2 CE Horizontal terminal Shorting b contact Motor charging device T AE1600 SW gt VDE IM Vertical terminal T Lifting hooks jii Closing coil TES AE2000 SWA JIS C 8201 2 1 Front terminal Safety shutter Shunt trip device AE2000 SW GB 14048 2 CCC Safety shutter lock Under voltage trip device Ey AE2500 SW Mis insertion preventor Condenser trip device S AE3200 SW Approvals Test jumper Trip Coil Man Aut Reset Type oa AE4000 SWA pprova AE4000 SW LR AE5000 SW GL uA AE6300 SW A ABS Fixed type I e e CUN CO NK Push button cover General use Extension module CC Link Interface unit Moisture fungus treatment Counter WS type Display PROFIBUS DP Interface unit Corrosion resist Cylinder lock MCR switch MODBUS Interface unit IM Terminal cover L4 Ta P protection use ii Neutral CT MB O unit gt Door frame On request External ZCT Dust cover l Special use VT W unit Interphase barrier WB type Mechanical interlock Door interlock Optional G1 Ground fault protection ET Earth leakage protection AP 2nd Additional Pre alarm N5 Neutral pole 50 96 protection For details on our full range including accessories contact your local distributor MITSUBISHI ELECTRIC 5 v E gt q v o ca LL lt L VN SAE Base Units Specifications CCEEBBETUTEBENTE TET SUPER AE WORLD
25. has been designed for panel doors with the groove on the left standard Locks for grooves on the right are available on request A wire type mechanical interlock is used to allow flexibility in positioning breakers in the panel Specifications DI F W Application breaker For all breakers Breaker type Fixed 168545 Order information Art no MI 403D W MI 404D W MI IW W AE2000 3200 SW AE4000 SWA Wire set for all mechanical interlock devices required for combination of 3 ACBs 3 4 168969 168970 168971 Note When using the door interlock DI the applica tion of the mechanical interlock MI is not possible DI D W For all breakers Drawout 168546 s MITSUBISHI ELECTRIC B Push button cover BC L B Dust cover DUC B Terminal cover TTC SX MITSUBISHI ELECTRIC This mechanical device can be locked with a pad lock or a seal both is not included in the pack age to protect the push buttons of the breaker unit against inadvertent ON OFF operation The padlock has to be supplied by the customer The transparent dust cover is hinged onto the panel door It has a screw lock and prevents dust and water entering into the circuit breaker The terminal cover is a transparent cover for safety finger protection of control terminals The terminal cover prevents from
26. ies UVT coil art no 168525 UCON label art no 168526 Packing unit 10 pcs Notes Please order for each UCON one UVT coil and for delay setting one UCON lable n case of 380 460V AC the external unit is attached The operating time is a guarantee value when it drops from 85 96 or more of rated voltage Time delay should be allowed for 1 5 s between applying the voltage to the UVT and closing the breaker If a remote trip function is required remove the shorting bar DT1 DT2 and connect a normally closed switch rated 0 5 A at 150 V DC across them Usage ambient temperature is a range of max 40 C to 5 C Bi Closing coil CC by remote control Only one closing signal about 100 msec is sent even when the closing coil supply is maintained ON amp An interlock to prevent pumping is provided Breaker ot Control supply Diode rectifier is not used for control source 24 48 V DC 12 One NK pulse i circuit electrically Specifications CC D048 W Rated voltage V 24 48DC Applicable voltage range V 18 52 8 Operating voltage V 24 48 CC unit mU Inrush current MEI ple pu 3 6 DEAV100W ji DC 48 V 200 W 7 Closing time sec max 0 08 or less MU I Order information Art no 168521 l
27. ing both electronically and mechanically The circuit of the motor is separate from the ON OFF circuit CC SHT MD D024 W MD D048 W 24V DC 48V DC 18 26 4 36 52 8 24V 48V 22 14 6 3 lt 5 lt 5 500 500 168518 168519 Manual reset type TCM AL W On the manual reset type optional the gray manual reset button will stick out to continu ously output OCR alarm AL if the breaker is tripped by the electronic trip relay After trip ping the breaker can not be turned on unless the manual reset button on the front side of the breaker is pressed for resetting TCM AL W 125 240 30 125 240 503 4 0 4 0 2 32 3 0 4 0 2 168536 Though the control power supply is unnecessary to activate OCR alarm AL the self holding circuit is necessary since the contact output is activated for the short time 30 ms This works when tripping occurs in LTD STD INST GFR or ER If any continuous output of OCR alarm AL is necessary use the trip indicator Tl output contact of the electronic trip relay 11 NJ SAE Accessories SAE Accessories HM Undervoltage trip device UVT Time range for tripping time INST 0 2 sec or less 0 25 sec 0 5 sec 0 8 sec 1 0 sec 1 5 sec 3 sec This is the device that automatically trips the breaker when the circuit voltage drops below the nominal voltage and comprises a UVT coil and UVT controller MITSUBISHIC NJ Time
28. ions AP W in standard ETR the 2nd additional Pre Alarm i i i Optional setting Module AP 2nd Pre alarm module function can be installed as option thereby it is possible to monitor observer electric circuit Order information Art no 168560 in more detail by 2nd additional Pre Alarm function Pre alarm timing chart Current m O O l Current PAL LED Ko Blinking PAL OUT contact output I I I ON OFF I 1 2 TL I I Setting item Adjustable setting range Accuracy Setting for shipment 2nd additional Ip 0 5 0 6 0 7 0 8 0 84 0 88 0 92 0 96 1 0 x lu WS 10 WS 10 Pre alarm pick up current P 05 0 6 0 7 0 8 0 84 0 88 0 92 0 96 1 0 x IL WM 5 WM 2nd additional 3 1 5 0 8 0 5 0 3 0 15 lt 0 1 0 1 0 15 0 3 0 5 0 8 1 5 3 s at 1 5 x lg Pre alarm time p TRIP ALARM an 20 26 s MITSUBISHI ELECTRIC SAE Electronic Trip Relay HM Neutral pole 50 protection N5 Neutral pole overcurrent protection operating Specifications N5 W at 100 of rated current already installed in N5 Neutrale pole protection TYPE N5 standard ETR Optional setting Module ode m But if you would like to operates at 50 of ETE EEE o EIOS rated current on neutral pole neutral pole 5096 protection realizes it Bl Earth leakage protection ER By combining the ETR with earth leakage Specifications ZEN protection ER and External ZCT earth leakage protection is possible Earth
29. ition is held until it is reset Non self holding type The output is reset if it is returned to the normal condition 22 Aa MITSUBISHI ELECTRIC SAE Electronic Trip Relay CT rating table AE1000 SW AE1250 SW AE1600 SW AE2000 SWA AE2500 SW AE3200 SW AE4000 SWA AE5000 SW AE6300 SW 1000 A 1250A 1600 A 2000 A 2500A 3200A 4000 A 5000 A 6300A 250A 315A AE2000 SW AE4000 SW 500A 630A 2000 A 4000 A 1250A 1600 A Notes AE1000 SW and AE2000 SW has low rating types too As for details of ratings refer to pages 6 and 7 Electronic trip relay ETR configuration overview Additional function Extension module EX1 Network Main setting module Optional setting module Power supply G1 Ground fault protection P3 AC 100 240 V DC100 125 V ll Display DP1 li BIF PR WS1 WM1 EN N5 Neutral pole 50 protection with output eer ll Display onto panel board DP2 W BIF MD AE4000 SW E1 Earth leakage protection P4 DC 24 60 V with B VT W unit output contact AE2000 SWA AP 2nd Additional Pre alarm B nk Me BI MCR switch MCR SW WS2 WM2 AE4000 SWA die i A with output contact SSR The assignment of the contacts can be changed with DP1 DP2 The output of G1 E1 AP PAL OUT can also be changed to the self holding type from the non self holding type WS General use WM Generator protection use WB Special use on request Aa MITSUBISHI ELECTRIC 23 SAE Electronic Trip Relay E SAE Electronic T
30. leakage protection earth leakage tripping and earth leakage alarm can be selected Control supply is necessary for Order information Art no 168559 this function E1 Neutrale pole protection Optional setting Module module Setting item Adjustable setting range Accuracy Setting for shipment 0 ER pick up current lAn 1 2 3 5 10A 30 10A 3 1 5 0 8 0 5 0 3 0 15 lt 0 1 0 1 0 15 0 3 0 5 0 8 1 5 3 s at 1 5 x lin ER time Te TRIP ALARM 20 3 s TRIP ll MCR switch MCS W If MCR switch is built in the breaker and the dial Specifications MCS W for INST MCR on Main setting module is set to Optional setting Module MCR any MCR position MCR function is operative MCR function During a closing operation of Order information Art no 1685 0 the breaker Instantaneous characteristics is operative And it becomes inoperative when the breaker is in the closed position MITSUBISHI ELECTRIC 27 SAE Electronic Trip Relay E SAE Electronic Trip Relay Bl Extension module EX1 This is the module that realizes various addi tional functions combining Display module DP1 DP2 Interface unit BIF CC BIF PR BIF MD and VT W unit Various measuring elements high measur ing accuracy By adopting high performance ASIC various measuring elements load current voltage energy harmonics etc and high measuring accuracy are realized Type Extension Module Order infor
31. mation Art no 168564 This is the module that displays and sets various information for example measurement trip and alarm setting of output contacts and so on Multi display of measuring element It enables to easily monitor the comparison of each measuring element by multi display load current 4 phases multi display and volt age multi display on one screen 2 colours back light If trip or alarm occurred back light colour changes from green to red automatically Spedification DP1 W Type Display module for ETR assembly Order information Art no 168565 Notes Extension module EX1 is required Communication function 2 display modules and 1 interface unit can be connected simultaneously by internal com munication Setting item Adjustable setting range Graphical display By adopting dot matrix type LCD graphical display such as bar graph display of load current harmonic currents and characteristic curve are realized There are 2 types of this module One is the ETR attachment type DP1 Another is the panel attachment type DP2 and is connected to extension terminals of control circuit by 2 m cable 5 m cable will be available on request DP2 W Display module for Panel assembly 168566 The VT W measurement module is required to display the measured data except the electric current E Measurement module VT W The VT W measurement module enables to measure voltages pow
32. o AE4000 SWA Please apply for further details of AE4000 SW to AE6300 SW Further the interlock is possible among the different connection types or poles such as fixed type or drawout type 3 pole or 4 pole In combination with electric interlock the higher safety interlock system can be secured mie 00000000 ENNO OO O BRO OOO MOO O Ol EE OO 00 MO OG 0 EO OO In case of drawout type the interlock works at CONNECTED position and in another position the interlock is released which is convenient for and easy maintenance and inspection of the breaker When to turn OFF one breaker and then turn ON another breakers please take an interval 0 5 seconds or more MI for 3 breakers can not be installed to combine with Door Interlock DI Switching states for 2 ACBs D ORO AB1 O O O O AB2 O O O OQ EN O O O i k k i i ACB2 ACB2 ACB2 i i i ACB ACB ACB3 Specifications MI 203F W MI 204F W Application breaker EN D Breaker type Fixed Number of poles 3 4 Order information Art no 168963 168964 B Door interlock DI Cabinet door N This mechanical interlock device makes it impossible to open the panel door unless the circuit breaker is not switched off 16 MI 403F W MI 404F W MI 203D W MI 204D W AE2000 3200 SW AE1000 1600 SW AE4000 SWA AE2000 SWA Drawout 3 4 3 4 168965 168966 168967 168968 The device
33. or information and trip and alarm informa tion These units are applicable to various open network systems such as CC Link PROFIBUS DP and MODBUS RS 485 which can be built in easily MELSECNET 10 Example AE SW and networks PC with MELSECNET 10 interface card AU Zz Y I O unit MELSEC PLC CC Link PROFIBUS DP MODBUS Eco Monitor Pro ME96NSR Specifications BIF CC W BIF PR W BIF MD W Main setting Module S type CC Link network PROFIBUS DP network Modbus network Order information Art no 168571 168572 168573 Note Extension module EX1 is required The VT W unit is required to display the measured data except the electric current The input amp output controlling unit BIF CON is or Spring charging Further by combining the available for the remote controlling and remote drawout position switch BIF CL the monitor monitoring of the breaker condition through ing of drawout position become available in the various network systems case of the breaker drawout type With this BIF CON in addition to the inter face unit it become possible to control the breaker remotely like a ON or OFF operations Function Description Note Breaker ON operation 1 a contact for CC Control Breaker OFF operation 1 a contact for SHT not applicable for AC 380 500 V rating Spring charge 1 a contact for MD In case of BIF CC and BIF MD max 3 contacts monitoring are available Monitor ERU es UDINE
34. pecial equipment Special equipment Available as accessory Optional accessory Remark m shipping version on request on request refer to page 15 on request Connection image AE1000 1600 SW 3 pole type Standard Fixed type breakers AE1000 1250 1600 2000 2500 3200 SW are also available as Drawout type Please order the corresponding cradle with the drawout mechanism see table on next page The following connecting methods are available for the AE2000 SWA AE4000 SWA and AE4000 SW AE6300 SW Connection Vertical connection Mounting method Standard Fixed type Drawout type DR VT Remark Special equipment on request Connection image AE2000 SWA 3 pole type For AE2000 SWA AE4000 SWA AE4000 SW AE5000 SW and AE6300 SW models vertical terminal only is available Available Connections Breakers A1000 SW AE1250 SW AE1600 SW AE2000 SWA AE2000 SW AE2500 SW AE3200 SW AE4000 SWA AE4000 SW AE5000 SW AE6300 SW Connections Horizontal o O o Fixed type FIX VT a us FIX VTA O O O O O O FIX FTA O O O e Q ian R m Horizontal e Q o o deter DR VT O O O O O o e O OR ORT O O O O O DR VTA O O a O O DR FTA O O O O O O Standard Option Not available 8 s MITSUBISHI ELECTRIC SAE Base Units Order information Air circuit breakers Standard series AE SW Fixed type
35. rip Relay Characteristic table Overview of tripping characteristics of main setting modules in combination with optional setting modules N5 Neutral pole 50 protection General protection G1 E1 AP Main setting module only Ground fault Earth leakage 2nd additional Pre alarm WS General use LTD STD INST MCR WM Generator protection use y LTD4 STD INST MCR SAE Electronic Trip Relay Note WB type for special use is available on request Power supply modules Product overview Contact capacity Type code P3 P4 Type Rating Alarm output contacts 100 240 V AC P3 100 125 V DC 6 output contacts Resistive load Inductive load Voltage V coso 4 0 L R 7 ms 240 1A 0 5A P5 100 240 V AC 6 output contacts SSR AC Di m i Note DC 125 0 1A 0 05 A 30 1A 1A P4 24 60 V DC 6 output contacts Over current protection and ground fault protection operates without control power source Contact capacity Type code P5 Voltage V Normal Peak inrush ON resistance g current current max Factory setting of 6 output contacts is as follows MO 01A TEN T 120 0 1A 0 3 A 50 G1 E1 AP LTD STD INST PAL 125 0 1A 03A 50 DC l i Ha Self Self Non Self Non Self Non Self 30 0 1A 0 3 A 50 holding holding holding holding holding table Type G1 E1 AP TRIP side Selfholding Selfholding Non Self Non Self Non Self AE Hae holding holding holding Description Self holding type The output cond
36. rip Relay S Types General Protection Load current LEDs Q Current Ir setting dial Q INST MCR pick up current li setting dial MCR option Uninterrupted current lu RUN LED setting dial ERR LED Pre alarm LED LTD time Ti setting dial lt 5 rt Isd xlr on Tsd s OFF Q STD time Tsa setting dial Trip indicator LEDs Q STD pick up current Isa setting dial L S l Adjustable setting range Setting item Adjustable setting range Accuracy Setting for shipment Current setting lr 0 5 1 0 0 05 step x In CT rating 1 0 1 05 x lu Non Pick up e Uninterrupted current lu 0 8 1 0 x Ir 0 02 step Pick up current 1 15 x lu 1 25 xu Pick up 1 0 O LTD time TL 12 25 50 100 150 s at lu x 2 20 150 Q STD pick up current lsd 1 5 2 2 5 3 4 5 6 7 8 9 10 x Ir 15 10 0 5 0 4 0 3 0 2 0 1 0 06 0 06 0 1 0 2 0 3 0 4 055 S 20 I t ON 14 OFF This means it operates in the range z dan Ls between 0 04 and 0 08 s when the time 0 5 t ON at Isd x 1 5 set at 0 06 s AE1000 SW AE1600 SW 16 12 10 8 6 4 2 2 4 6 8 10 12 16 x Ir ue eM WS1 INST MCR WS1 16 INST o INST MCR li AE2000 SWA AE4000 SWA 12 10 8 6 4 2 2 4 6 8 10 12 x Ir 15 pick up current AE5000 SW i WS2 NT MAO WS2 12 INST AE6300 SW Vee WS3 10 INST Pre alarm current Ip lux 0 68 1 0 0 04 step OVER 1096 OVER O Pre alarm time Tp 1 2TL after 1 2 TL PAL contact output turns
37. s AE4000 SW AE4000 SW 3P Fix ETRBASE P3 AX10 205144 AE4000 SW 3P D O ETRBASE P3 AX10 205153 e Be iei base unit AE5000 SW AE5000 SW 3P Fix ETRBASE P3 AX10 205145 AE5000 SW 3P D O ETRBASE P3 AX10 205154 10 auxiliary contacts 5 NO 5 NC contacts AE6300 SW AE6300 SW 3P Fix ETRBASE P3 AX10 205146 AE6300 SW 3P D O ETRBASE P3 AX10 205155 Automatic reset type trip coil TCA AL W Switch disconnector AE SW Fixed Drawout type Shipping contents AE1000 SW AE1000 SW 3P Fix Bare AX10 193919 AE1000 SW 4P Fix Bare AX10 193920 10 auxiliary contacts 5 NO 5 NC contacts Switching capacity I AE1250 SW AE1250 SW 3P Fix Bare AX10 193921 AE1250 SW 4P Fix Bare AX10 193922 Further elements that must be ordered AE1600 SW AE1600 SW 3P Fix Bare AX10 193923 AE1600 SW 4P Fix Bare AX10 193924 E OE ATEUNIR AE2000 SW AE2000 SW 3P Fix Bare AX10 193929 AE2000 SW 4P Fix Bare AX10 193930 AE2500 SW AE2500 SW 3P Fix Bare AX10 193931 AE2500 SW 4P Fix Bare AX10 193932 AE3200 SW AE3200 SW 3P Fix Bare AX10 193933 AE3200 SW 4P Fix Bare AX10 193934 AE4000 SWA AE4000 SWA 3P Fix Bare AX10 195955 AE4000 SWA 4P Fix Bare AX10 193936 AE2000 SWA AE2000 SWA 3P D O Bare AX10 193927 AE2000 SWA 4P D O Bare AX10 193928 AE2000 SWA AE2000 SWA 3P Fix Bare AX10 193925 AE2000 SWA 4P Fix Bare AX10 193926 AE4000 SWA AE4000 SWA 3P D O Bare AX10 193937 AE4000 SWA 4P D O Bare AX10 193938 ata MITSUBISHI ELECTRIC 9 SAE