1. 0000000 Fan 5 Power Supply 1 Power Supply 2 Power Supply 3 Fan 2 Fan 1 Fan 3 o 0o XA o Oo a o nNn Fan 4 o Power Blank Chassis UID N SLAPM SL Advanced Power Manager connector w Fan 7 A Fan 8 ltem Designator Description 1 J System maintenance jumper 2 J301 PCle x16 slot 3 ul Processor 1 4 J11 Mgmt card connector 5 J110 DIMM slot 12 for processor 1 6 J103 DIMM slot 1 for processor 1 7 J210 DIMM slot 12 for processor 2 8 U2 Processor 2 9 J54 4 pin power connector 10 J52 24 pin power connector 11 J61 Fan connector 1 12 J62 Fan connector 2 13 J203 DIMM slot 1 for processor 2 14 J68 Backplane I C connector 15 J53 8 pin power connector 16 J63 J64 Fan connectors 3 4 17 J65 Fan connector 5 18 J49 Internal USB 2 0 port 19 J8 Front panel USB 2 0 port 20 J81 SD card USB 2 0 port 21 J100 SAS LED connector 22 J66 J69 Fan connectors 6 7 23 J55 Power backplane control connector 24 J13 Mini SAS connector for SATA 25 J98 Front panel header 26 J56 TPM connector 27 J78 PCle x4 slot 28 J23 ODD 1 SATA connector 29 J20 ODD 2 SATA connector 30 BH1 3V CMOS battery CR2032 31 J6 NMI jumper Server Configuration Resources In addition to this Installation Sheet other resources are avai
2. Rank DR Dual Rank QR Quad Rank Population rules must be followed for both processors Memory modules may be populated one at a time per processor but populating two at a time per processor provides better performance Memory modules should be populated four at a time per processor for best performance Quad Rank memory module can only be installed in memory sockets 2 5 8 and 11 A CAUTION DIMMs can be damaged by improper handling Always use an anti static wrist strap and grounding mat and discharge static electricity before touching DIMMs To install a memory module 1 Align the notch on the bottom edge of the module with the keyed surface of the DIMM slot and then press the module fully into the slot 2 Firmly press the holding clips inward to secure the memory module in place ure 7 Installing the memory module Fi DIMM slots are structured to ensure proper installation If you insert a DIMM but it does not fit easily into the slot you may have inserted it incorrectly Reverse the orientation of the DIMM and insert it again A ara m e 1 Properly align the heat sink mounting pins to the system board Installing the Processor Touring Hole To install the new processor 2 Tighten the mounting pins clockwise to secure the heat sink 1 Insert the processor in the tool connection to the system board 2 Align the processor installation tool with the socket and install the A CAUTION To prevent the he
3. the HP website http www hp com 7 Install a supported operating system of your choice For detailed procedures refer to the documentation provided by the operating system vendor For a list of operating systems supported by your ProLiant server go to http www hp com go supportos Pre and Post installation Procedures When installing additional options in your HP ProLiant SL165s G7 Server observe the following procedures Pre installation procedures 1 Turn off the server and all the peripherals connected to it 2 Remove the tray from the chassis by following the procedure described later in the Removing the tray section Post installation procedures 1 Be sure all components are installed according to the described step by step instructions 2 Check to make sure you have not left loose tools or parts inside the server 3 Reinstall the PCI riser peripherals and system cables that you have removed 4 Reinstall the tray into the chassis 5 Connect all external cables to the system 6 Press the power button on the front panel to turn on the server Removing the Tray You need to remove the tray from the chassis before you can remove or replace a tray component To remove the tray 1 Press the two handles on both sides at the same time to release the tray 2 Pull out the tray from the chassis until the release latch catches 3 Firmly holding the tray press the release latch on both sides
4. to HP ProLiant SL165s G7 Server Easy Set up CD You can also access additional information and documentation from the HP external website either by connecting directly or through the Easy Set up CD Legal notices Copyright 2010 2011 Hewlett Packard Development Company L P The information contained herein is subject to change without notice The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services Nothing herein should be construed as constituting an additional warranty HP shall not be liable for technical or editorial errors or omissions contained herein Part Number 635251 002 February 2011 Second Edition Printed in China 63525 1 002 251
5. HP ProLiant SL165s G7 Server Installation Instructions A Part Number 635251 002 A Important Safety Information Before installation read Important Safety Information on HP website hitp www hp com support importantsafetyinformation Garg cele HP Gn ADAN Dg Ada Ela gra il ciiil d P ed zah jen m instalace si p e t te d le it bezpe nostn informace uveden na webov m serveru spole nosti HP WTRAA WASH HP AEA ERREA o RSA GSR HP MULAN ERREA y gt Far installation laes Vigtige sikkerhedsoplysninger p HPs websted Lesen Sie vor dem Installieren das Dokument Wichtige Sicherheitshinweise auf der HP Website Enne paigaldamist tutvuge olulise ohutusteabega HP veebisaidil Antes de la instalaci n lea la secci n Informaci n de seguridad importante en la p gina web de HP Antes de proceder a la instalaci n lea la informaci n importante sobre seguridad en el sitio Web de HP Avant installation lisez attentivement le document Informations importantes relatives la s curit sur le site Web HP Merv an tny eykar craon laB ore tic Znpavrik nAnpo opies oxerikd pe THV acop dela otnv tonobecia tng HP oto web HP w onor ANNA Important Safety Information nx Np AANA 1197 Prije instaliranja pro itajte va ne informacije o sigurnosti na HP ovim web stranicama Prima dell installazione consultare la sezione Informazioni sulla sicurezza e sulle norme vigenti del sito Web di HP AYAR IVATICHPOWebt 4 b
6. asy Set up CD or hitp www hp com support Para obter instru es traduzidas consulte Easy Set up CD ou HP com Ubersetzte Gebrauchsanleitungen finden Sie auf der Easy Set up CD oder unter HP com Para obtener las instrucciones traducidas consulte el Easy Set up CD o la p gina web HP com Pour obtenir des instructions traduites reportez vous au CD Easy Set up ou visitez le site HP com PUR ENTRAN DU TI Easy Setup CDK fe ILHP come SiR LT lt ES 1680 Easy Setup CD Hihi HP com MERA Identifying server components Front panel components SL165s G7 Server Front Panel Components Figure 1 Front panel components of the s6500 chassis with 4 SL165s G7 servers S0C gfe aa J Item Description 1 UID LED Switch 2 Serial port 3 Top NIC4 Connector Bottom NIC3 Connector 4 Server 1 5 Server 2 6 Server 3 7 Power LED Switch 8 Health LED 9 NIC1 Connector 10 NIC2 Connector 11 Server 4 12 VGA port 13 Mgmt NIC Optional 14 Top USB 2 0 Port Bottom USB 2 0 Port 15 SD card slot Optional Rear Panel Components Figure 2 Rear panel components of the s6500 chassis with 4 SL165s G7 servers ltem Description Fan 6 System Board Components Figure 3 System Board Components
7. at sink from tilting to one side processor during installation removal turn each screw a couple of turns alternatively between both of them and then apply the final torque Do not over tighten the spring loaded screws to prevent them from breaking off A maximum torque of 4 5 inch lb is set for each screw Figure 8 Installing the processor Figure 10 CPU 1 installing the heat sink with 17 fin pitches ES IMPORTANT Be sure the processor remains inside the processor installation tool 1 Press down firmly until the processor installation tool clicks and separates from the processor and then remove the processor installation tool 2 Close the processor socket retaining bracket and the processor retaining latch Figure 9 Removing the processor installation tool and close the processor socket A CAUTION Be sure that the heat sink sits squarely on the processor or overheating and damage to the processor may occur ES IMPORTANT If the heat sink has been removed for any reason it is critical that you apply more thermal interface material to the integrated heat spreader on the processor to ensure proper thermal bonding between the processor and the heat sink Clean the contact surface of both the processor and heat sink For processor removal reverse the above installation procedures To install the heat sink ES IMPORTANT The one close to front panel is processor 1 and the other one is processor 2 During install t
8. he heat sink make sure to install heat sink 1 on the processor 1 with 17 fin pitches while heat sink 2 on the processor 2 with 38 fin pitches with an alcohol pad then re apply an HP approved thermal interface material before reinstalling the processor Use a pattern of five dots when applying the thermal interface material one dot in the center and one dot at each corner NOTE Do not over tighten the heat sink s spring loaded screws to prevent them from breaking off Installing the DIMM Air Baffle NOTE The DIMM air baffle is required for proper thermal solution 1 Hold the latch on the top of the DIMM air baffle and align it to the system board 2 Press down to make sure the DIMM air baffle completely installed NOTE To check and ensure the 2 ribs are installed between DIMM1 and DIMM2 DIMM11 and DIMM1 2 Figure 12 Installing the DIMM air baffle into the tray lt Q a SS Installing the CPU Air Baffle NOTE The CPU air baffle is required for proper thermal solution To install the CPU air baffle 1 Align the CPU air baffle to the tray 2 Secure the left latch to the left bracket the middle latch to the middle bracket and the right latch to the PCle x16 bracket on the tray 3 Press down the CPU air baffle to make sure it completely installed on the tray Figure 13 Installing the CPU air baffle into the tray FETAL Additional Documentation For additional documentation refer
9. k C FRAIMEFAL TLE HEALER ESEL MAB AZS Moll HP A ALEAN FL A FAS HEHE Pirms instal Sanas izlasiet sada u Svar ga dro bas inform cija HP m jas lap Prie jdiegdami perskaitykite Svarbig saugos informacij pateikt HP tinklalapyje A telep t s elott tekintse t a HP webhely n tal lhat fontos biztons gi tudnival kat Lees Belangrijke veiligheidsinformatie op de HP website voordat u aan de installatie begint Les Viktig informasjon om sikkerhet p HPs nettsted f r du installerer Przed instalacj przeczytaj Wa ne informacje dotycz ce bezpiecze stwa w witrynie sieci Web firmy HP Antes de instalar leia o documento Informa es importantes de seguran a no sitio web da HP Antes de instalar leia o documento Informa es importantes sobre seguran a no site da HP lepep yCTaHOBKO O3HOKOMbTECb C poxymentom YkazaHna no rexHnke 6esonacHocm Ha Beb yane HP Pred in tal ciou si pre tajte l nok D le it bezpe nostn inform cie na webovej lokalite spolo nosti HP Pred namestitvijo preberite razdelek Pomembne varnostne informacije na HP jevem spletnem mestu Lue ennen asennusta T rkeit turvallisuusohjeita HP n verkkosivuilta Innan du installerar ska du l sa Viktig s kerhetsinformation p HP s webbplats Y klemeden nce HP web sitesindeki nemli G venlik Bilgileri b l m n okuyun Tepe scraHosnenham npountalite Baxnnsy inpopmayito 3 6esnekn Ha seb ca ti HP For translated instructions see the E
10. lable for more information regarding the configuration and maintenance of your server e For safety information and detailed procedures relating to installation of options refer to any installation instructions that came with the option as well as the HP Proliant SL165s G7 Server Maintenance and Service Guide e For safety information regulatory notices and detailed procedures related to the rest of the steps listed in the Configuring the Server section refer to relevant chapter of the HP ProLiant 16000 6500 Scalable System User Guide e For information relating to system BIOS configuration and operating system installation refer to relevant section of the HP ProLiant SL165s G7 Server Software Configuration Guide e You can also access additional information and documentation from the HP website at http www hp com servers proliantsl165s Server Configuration Overview The steps listed below give an overview of the necessary setup procedures for preparing the HP ProLiant SL165s G7 Server for operation 1 Connect the AC power cord and peripheral devices 2 Power up the server 3 Press F10 to enter BIOS setup 4 Note the server BIOS version 5 Verify the server BIOS version against the latest BIOS version listed for this server on the HP website http www hp com 6 Ifyou do not have the latest BIOS update the BIOS now Refer to the HP Proliant SL165s G7 Server Maintenance and Service Guide available on
11. of the tray 4 Remove the tray from the chassis Figure 4 Removing the SL165s G7 server tray Installing the Hard Disk Drive One SL165s G7 server tray can accommodate up to 6 LFF SATA 4 LFF SAS or 8 SFF SATA SAS Non HotPlug hard disk drives and the chassis can accommodate 4 server trays for up to 24 LFF SATA or 32 SFF Non HotPlug hard disk drives The server supports both SAS and SATA hard disk drives NOTE For specific supported hard drive configurations and cable routing refer to HP ProLiant SL165s G7 Server Maintenance and Service Guide located on the HP website http www hp com support ProLiant_SL165sG7_MSG_en A CAUTION Drives can be damaged by static electricity Before handling drives touch an unpainted metal surface to discharge static electricity To install the LFF hard disk drive in the server tray 1 Unlock the HDD carrier latches 2 Liftthe HDD carrier handle up 3 Insert the HDD carrier and align the pins 4 Press the HDD carrier handle down 5 Lock the HDD carrier latches Figure 6 Installing the hard disk drive Installing the Memory Module Memory Module Population Order From lett to right RDIMM population order without QR DIMM Memory 1 7 4 103 9 6 12 2 8 5 11 Socket UDIMM population order without QR DIMM Memory 1 7 4 103 9 6 12 X X X X Socket Population order with QR along with SR DR DIMM Memory 2 8 5 11 1 7 4 103 9 6 12 Socket NOTE SR Single