Home
IP1500/2500
Contents
1. 4 1 8 gt al Code Blue 259 Hedcor Street Holland MI 49423 USA 800 205 7186 www codeblue com page 8 of 21 GU 136 G Code Blue IP1500 2500 y User Guide 5 Installation The IP1500 2500 comes in surface and flush mount options The surface mount allows the mount ing bracket to be installed during rough in and the faceplate with electronics during completion The faceplate on the flush mount is five inches square and provides an overlap to the mounting box to eliminate additional trim work 5 1 Surface Mount IP1500 IP1500 Surface Mount 4 50 w x 4 50 h x 2 00 d 4 56 gt 1 38 r a 7 j S I f 4 O O i 6X 15 THRU ALL N 28 X 82 4 56 3 28 l J t Back View Four Square Box by Others M Mount standard four square Gasket box to stud by Code Blue Me f Place gasket between Mount Mounting Bracket ing Bracket and Four Square by Code Blue Box Attach mounting bracket to Surface Mount Box Q four square box with 4 4 by Code Blue a a screws Connect CAT 5e cable to the Ethernet port on the PCB Attach surface mount box to mounting bracket with 3 4 1 SI security screws provided Vertical 3 4 Security Screws Orientation n by Code Blue __ 4 4
2. Code Blue IP1500 2500 y User Guide 6 3 Network Setup Setting a Static IP Address Once you have obtained the DHCP address of the IP1500 2500 and are logged into the speaker phone you have the option of leaving the speakerphone set at DHCP default setting or setting a static IP address To set a static IP address Click on the Network menu item under Network Setup see far left hand column Under the General section select Static IP as the Connection Type Enter your desired IP settings under the Static IP Address heading Once you have entered all your settings click on Save Changes ON Note If you have moved your IP1500 2500 to a network your PC cannot access you will have to configure your PC to access that network before configuration can continue IP1500 2500 Configuration Network Setup General Auto logout 09 27 Host 172 1 100 61 Domain Connection Type Dynamic IP Static IP Static IP Address Address 0000 Mask 255 255 0 0 Account 1 Default Router 0 0 0 0 Account 2 DNS Primary 0000 Media Advanced DNS Secondary 0 0 0 0 ii DNS Tertiary 0 0 0 0 Administration Date Time Additional Settings lt Upgrade Firmware MTU Size advanced 1500 VLAN Enabled Numbers ID 4 value 0 to 4094 Recordings Hardware Settings User Priority 0 Best Effort x default 0 General Settings Save Changes Action Scripts Diagnostic Settings Co
3. 6 1 Connecting to the IP1500 2500 Speakerphone The IP1500 2500 speakerphone may also be configured via a TFTP server which can be set up in your DHCP configuration To begin configuring the network settings follow the steps below 1 Connect the IP1500 2500 speakerphone to your network and connect to a PoE switch The LED indicator s will flash for a moment and you will hear an audible beep out of the speaker to indicate that the operating system is loading The IP 1500 2500 will acquire the IP network settings from your DHCP server 2 Check your DHCP lease records or utilize a network scanner such as SoftPerfect Network Scanner to match the MAC address of the IP 1500 2500 speakerphone to the correct IP address in your lease table or output of the network scanner 3 Once you have obtained an IP address you can now connect to the IP1500 2500speakerphone using a web browser by placing its IP address https IP 1500 2500 IP Address in the URL address bar and press ENTER 4 Atthe login prompt the default settings are a Username admin b Password admin IP Address 172 1 100 234 00 0f peg G aes I Berhad oe IP5000 STII 04 52 45 2010 09 29 10 32 49 172 1 100 228 00 1c c0 b0 41 e6 IP5000 2010 09 29 05 26 40 2010 09 29 17 26 40 172 1 100 238 00 1c c0 b0 3a 20 IP5000 2010 09 29 09 17 08 2010 09 29 21 17 08 172 1 100 7 4 00 0 IT I7 3163 IP3000 2010 09 29 09253235 2010 09 29 214255535 HAT be E E LL E amp Web site Range From 1
4. one ayn FORHEL QD A Gaal 73 E i 3 a a gp GE i I gt A Oa d s f gp P1500 2500 Speakerphones Configuration amp Operation User Guiqe v A Code Blue 800 205 7186 www codeblu Tr D 4 v Table of Contents IP1500 2500 User Guide Section Page Z MUOGUCHOM oinpera nanara eee sans nne entame caen 3 2 Geng SA eer ee ee 4 3 1 What s included with the 1P1500 1501 4 3 2 What s included with the 1P2500 2501 5 4 Connectors Ports and Switch List 6 4 1 1P1500 2500 Printed Circuit Board Layout 6 4 2 Wiring Diagram 1P1500 1501 icc cieceseccedcssaccavedsduasteveens 7 4 3 Wiring Diagram 1P2500 2501 8 3 MSAA UON aa RET E E 9 5 1 Surface Mount PS0 a 9 32 Flush MONO PS en eaen 10 5 3 Surface MODE AS 0 a ans se 11 5 4 Flush Mount PAS ee men 12 6 Configuring the IP1500 IP2500 Network Settings 13 6 1 Connecting to the IP 1500 2500 Speakerphone 13 6 2 System Status Screen eo ee 14 6 3 Network Setup Setting a Static IP Address 15 6 4 Network Setup VLAN Configuration 16 7 TRESECL 0 Defaults ane tea 17 8 Troubleshooting the IP1500 2500 Speakerphone 18 9 Technical Specifications 19 RO E EE 20 NA
5. Use the mounting plate as your guide on the wall mark the mounting and conduit holes Remove the rear mounting plate and create the required holes attach the mounting plate to the wall Pull CAT 5e cable through the conduit hole in the rear mounting plate Connect CAT 5e cable to the Ethernet port on the PCB Slide the IP2500 case down starting from the top of the rear mounting plate Replace the two retaining screws page 11 of 21 GU 136 G ES Tr D 4 v 5 4 Flush Mount IP2501 IP2501 Flush Mount 9 00 w x 9 00 h Calling Answered S Code Blue Ve t Orientation Code Blue 259 Hedcor Street Holland MI 49423 USA 800 205 7186 www codeblue com Back View IP1500 2500 User Guide lt 4 13 gt Bottom View First remove the four faceplate screws from the back box Use the back box as your guide on the wall mark the rough opening size Create the required opening and conduit runs Pull CAT 5e cable through the conduit hole in the back box Connect CAT 5e cable to the Ethernet port on the PCB Attach faceplate to back box Replace the four faceplate screws page 12 of 21 GU 136 G Code Blue IP1500 2500 User Guide 6 Configuring the IP1500 IP2500 Network Settings The IP1500 IP2500 is DHCP configured by default
6. 8 a m to 6 p m Monday through Thursday and 8 a m to 5 p m Friday Eastern Time Code Blue 259 Hedcor Street Holland MI 49423 USA 800 205 7186 www codeblue com page 18 of 21 GU 136 G A ER ln EE TR Code Blue IP1500 2500 y User Guide 9 Technical Specifications Full duplex speakerphone intercom and paging device 1MB memory storage for phone numbers and audio messages Phone numbers up to 255 digits long SIP IAX2 Protocol support STUN client for NAT transversal UDP TCP and TLS 1 x IEEE 802 3 10 100 Ethernet port Embedded web server Security includes HTTPS Transport Layer Security TLS SRTP RFC3711 SIPS RTCP VLAN Password protection DTMF inband out of band INFO 1 x Active Touch data button inputs 1 x auxiliary N O output contact closures with programmable timing capability Self monitoring and fault reporting Communication service Button failure Speaker failure Microphone failure Message Playback options Multiple and repeating during call placed Multiple and repeating during call received Message playback during a call via DTMF commands In Call commands via DTMF Auxiliary output control Incremental increase decrease speaker microphone Message playback Built in scripting language provides advanced button and diagnostic report programming Corrosion resistant connectors Enhanced speakerphone and microphone sensitivity Non volati
7. Screws by Others Code Blue 259 Hedcor Street Holland MI 49423 USA 800 205 7186 www codeblue com page 9 of 21 GU 136 G Code Blue Tr D 4 v 5 2 Flush Mount IP1501 IP1500 Flush Mount 4 00 w x 5 00 h 1 72 IP1500 2500 User Guide 3 4 Conduit Thread IP1501 Faceplate 7 1 Vertical Orientation y Four 6 Security Screws Bottom View IP1501 Weatherproof Back Box Mount the weatherproof back box to an inside wall or onto a surface Connect a minimum of CAT 5e cable to the Eth ernet switch port PoE LAN for connectivity to the network Attach the faceplate to the back box with the four 6 security screws provided Connect any auxiliary device to the N O aux output 1 Code Blue 259 Hedcor Street Holland MI 49423 USA 800 205 7186 www codeblue com page 10 of 21 GU 136 G Code Blue tr lt v 5 3 Surface Mount IP2500 IP2500 Surface Mount 7 25 w x 7 25 h x 2 00 d gt Orientation Code Blue 259 Hedcor Street Holland MI 49423 USA e 800 205 7186 www codeblue com Back View IP1500 2500 User Guide 2 88 KNOCK OUT Bottom View First remove the two retaining screws one from each side of the case Remove the rear mounting plate by sliding it downward
8. Tr D 4 v Code Blue IP1500 2500 User Guide 4 Connectors Ports and Switch List The IP1500 2500 is a compact design small enough and light enough to ensure an easy installation at any new or existing location The IP1500 2500 has one PoE LAN port IEEE 802 3 10 100 Ether net Port for connecting to a network A single normally open auxiliary output is available to trigger door locks lights gates or any other security device The internal components consist of a microphone connector a speaker connector one PoE LAN port a button connector s one normally open auxiliary output and PCB mounting hardware 4 1 IP1500 2500 Printed Circuit Board Layout Microphone Connector LED Button C t D nada Speaker Connector Auxiliary Output N O PoE LAN Port The IP 1500 1501 is solely powered by PoE 802 3at and af Class 0 upon initialization PoE Receptacle Auxiliary Output 1 Signal Code Blue 259 Hedcor Street Holland MI 49423 USA 800 205 7186 www codeblue com page 6 of 21 GU 136 G Code Blue tr lt v 4 2 Wiring Diagram 1P1500 1501 IP1500 2500 User Guide The IP1500 1501 has one PoE LAN port for network connectivity and one normally open auxiliary output relay for triggering devices such as a LED beacon strobe camera preset activation inputs gate control or third party controllers The relay can be programmed to hold the relay closed for the duration of the call for a specific time
9. 0 42 4 f f 355 2 Fl lb Start Scanning If IF Address eg 10 42 4 1 a 10 42 4 2 1 10 42 43 mg 10 42 4 4 g 10 42 4 5 5 10 42 4 17 a 10 424 21 me 10 42 4 22 ie 10 42 4 235 me 10 42 4 24 1 10 42 4 25 d 10 42 4 26 me 10 42 4 27 d 10 42 4 19 B 10 42 4352 A 10 424 35 10 42 4 35 Host Name arthur vlan3004 pde codeblue local wrt160n pde codeblue local eddie pde codeblus local benjy pde codeblue local dhcp 4 17 pde codeblue local dhcp 4 21pde codeblue local dhcp 4 22 pde codeblue local dhcp 4 235 pde codeblue local dhcp 4 24 pde codeblue local dhcp 4 25 pde codeblue local dhcp 4 26 pde codeblue local dhcp 4 27 pde codeblue local dhcp 4 19 pde codeblue local dhcp 4 32 pde codeblue local dhcp 4 33 pde codeblue local dhcp 4 35 pde codeblue local Threads 0 Devices 38 s MAC Address 00 11 43425 2E 6 68 7F 74 25 B88 C9 00 22 58 60 53 65 90 FB A6 25 69 FC 00 40 48 46 9 43 98FE 94 45 45 08 7C D1 C3 48 47 34 00 26 60 85 63 DF 00 E0 4C EC 01 F6 00 04 F 2 A6 A1 F A 00 10 18 AF 27 5F 74 4 34 61 45 00 00 04 F2 A5 90 2E FC C 34 09 27 93 00 04 F2 24 FA 1D 00 04 F2 A6 A2 02 00 50 C2 CB E1 35 Code Blue 259 Hedcor Street Holland MI 49423 USA 800 205 7186 www codeblue com Response Time Hosiname O ms Oms Oms eddie pde code Ooms benjy pde code ms 28 ms 35 ms 21 ms 7 ms O ms O ms ms O ms 177 ms O ms ms O ms page 13
10. E EEE 21 Code Blue 259 Hedcor Street Holland MI 49423 USA 800 205 7186 www codeblue com page 2 of 21 GU 1536 G PN a za nn Code Blue IP1500 2500 User Guide 2 Introduction Thank you for choosing the Code Blue IP 1500 2500 full duplex VoIP speakerphone s intercom and paging device s for indoor and outdoor applications These speakerphones are part of our Emergency Signaling group of products built to meet the latest regulations withstand the harsh est elements and be proactive solutions for when you need them most This guide provides basic installation and initial setup instructions for obtaining the best performance with the IP 1500 2500 speakerphone s Note Refer to the complete IP 1500 2500 Administrator Guide for basic and advanced speaker phone configuration see PUSH FOR HELP AT IP1500 Surface Mount IP2500 Single Button Surface Mount Code Blue 259 Hedcor Street Holland MI 49423 USA 800 205 7186 www codeblue com page 3 of 21 GU 136 G A AR ln EE TR Tr D 4 VW Code Blue 259 Hedcor Street Holland MI 49423 USA 800 205 7186 www codeblue com 3 Getting Started 3 1 What s included with the IP1500 1501 IP1500 Surface Mount Quantity Part No Description i __ Surface Mount Box mous __ Mounting Bracke a __ No 4 Security Screws 4 No 4 Screws Not Included a Four Square Box Not Included a Installation and Set Up Gu
11. and MI 49423 USA 800 205 7186 www codeblue com page 17 of 21 GU 136 G A SS EE TR Code Blue IP1500 2500 y User Guide 8 Troubleshooting the IP1500 2500 Speakerphone The IP1500 2500 speakerphone is a network device The following are tips for troubleshooting Power Ensure the power to your device is working and rated for 802 3af PoE specifications Ping Test This determines connectivity and the packet loss and latency time to and from your destination and the quality of your network connection to your IP1500 2500 If you receive no response and PoE power is confirmed contact your network administrator DHCP The IP1500 2500 is set up for DHCP by default If you cannot determine the IP address of your IP1500 2500 contact your network administrator Account Ensure your SIP or IAX2 account is set up correctly Account username and password must match the account credentials on your VolP system Codec Ensure your codec settings on your VolP system match the IP2500 1500 codec settings Firewall Firewalls commonly block or partially block VoIP calls Check with your network administrator if you cannot communicate with your IP 1500 2500 from behind a firewall Note If you do not have a DHCP server running use a standard home wireless router and plug your speakerphone and laptop into the same router Once you know the IP Address you can browse to it via your web browser Code Blue Technical Support 800 205 7186
12. e Corporation provides a limited warranty on this product Refer to your sales agreement to establish the terms In addition Code Blue s standard warranty language as well as information regarding support for this product while under warranty is available at www codeblue com support downloads Notice Every effort was made to ensure that the information in this document was complete and accurate at the time of printing Information is subject to change Code Blue 259 Hedcor Street Holland MI 49423 USA 800 205 7186 www codeblue com page 21 of 21 GU 136 G
13. ide Included A Standard Drilled Spanner Insert Bit is required to the access unit Not Included Drilled Spanner Insert Bit 1 4 Hex Shank 4 Screw Size 1 Length D ana Insert IP1501 Flush Mount Quantity Description EE Faceplate Included nn Weatherproof Back Box Included SS No 4 Security Screws Included pe No 4 Screws Included A Standard Tamper Resistant Insert Bit is required to access unit Not Included Tamper Resistant Torx Insert Bit 1 4 Hex Shank T10 1 Length Q Insert Code Blue IP1500 2500 User Guide page 4 of 21 GU 136 G A AR ln EE TR Code Blue IP1500 2500 y User Guide 3 2 What s included with the IP2500 2501 IP2500 Surface Mount Quantity Part No Description E Surface Mount Box Included a Mounting Plate included EE Retaining Screws Included a _ No 6Scews Notinauded a re Installation and Set Up Guide Included A Standard Security Bit is required for retaining screws Not Included IP2501 Flush Mount Quantity PartNo Description i a Faceplate Assembly Included o Weatherproof Back Box Included 4 __ Retaining Screws Included a Installation and Set Up Guide Included a Mounting hardware for Back Box Not Included A Standard Security Bit is required for retaining screws Not Included Code Blue 259 Hedcor Street Holland MI 49423 USA 800 205 7186 www codeblue com page 5 of 21 GU 136 G a SS
14. le memory ensures program ming is retained during power loss Conformal coated PCBs for environmen tal protection and operation ADA compliant with Braille signage and LED indicators ToolVox Media Gateway emails fault sta tus report about phone NEMA 4 IP 55 rated Dual account registration for redundancy Built with powerful DSP technology For IP1500 Only Standard Bezel Options Emergency Push For Help Emergencia Standard Surface Mount Housing Color Safety Blue Standard Flush Mount Faceplate Color Stainless For IP2500 Only Two highly visible LED indicators for ADA compliance for hearing impaired Optional dual button faceplate Code Blue 259 Hedcor Street Holland MI 49423 USA 800 205 7186 www codeblue com page 19 of 21 GU 136 G a ar 7 UN Code Blue IP1500 2500 y User Guide 10 Regulatory The IP1500 2500 speakerphone conforms to the following list of directives and product safety standards as applicable EU EN 55022 2006 A1 2007 EN 55024 1998 A1 2001 A2 2003 EN 61000 4 2 1995 EN 61000 4 3 2006 A1 2008 EN 61000 4 4 2004 EN 61000 4 5 2006 EN 61000 4 6 2007 EN 61000 4 8 1993 A1 2001 EN 61000 4 11 2004 EN 61000 3 2 2006 A1 2007 EN 61000 3 3 2008 USA CFR 47 Part 15 CANADA ICES 003e Code Blue 259 Hedcor Street Holland MI 49423 USA 800 205 7186 www codeblue com page 20 of 21 GU 136 G Code Blue IP1500 2500 y User Guide 11 Warranty Code Blu
15. of 21 GU 136 G A a mm EE UN Tr D 4 v Code Blue 6 2 System Status Screen IP1500 2500 User Guide The System Status Screen displays the current session time before an Auto Logout is executed Clicking Renew will restart the timer to 10 minutes effectively keeping you logged into your session Clicking on Logout under Session will log you out of the Administration Interface and you will be prompted to click OK or Cancel The Network information displays the current IP address Gateway DNS address and DNS Tertiary address The system status screen also shows Account 1 and Account 2 Registration Status Auto logout 09 44 Renew Logout Network Account i Account 2 Media Advanced Administration Date Time Upgrade Firmware Cai Glee Con fm on Batch Configuration Numbers Recordings Hardware Settings General Settings Action Scripts Diagnostic Settings IP1500 2500 Configuration System Status Address Gateway DNS Primary DNS Secondary DNS Tertiary Protocol User Registration Status STUN Enabled Protocol User Registration Status 172 1 100 148 1 2 1 100 1 172 1 100 61 0 0 0 0 0 0 0 0 Account 1 SIP 6116 172 1 100 61 PROXY REGISTERED Disabled Account 2 Disabled copyright 2013 Code Blue Code Blue 259 Hedcor Street Holland MI 49423 USA 800 205 7186 www codeblue com page 14 of 21 GU 136 G
16. ordings Hardware Settings User Priority 0 Best Effort default 0 General Settings Nae Save Changes Action Scripts 0 Best Effort Diagnostic Settings 3 Excellent Effort 4 Contoted Load 5 Video lt 100ms latency and jitter 6 Voice lt 10ms latency and jitter 7 Network Control Code Blue 259 Hedcor Street Holland MI 49423 USA 800 205 7186 www codeblue com page 16 of 21 GU 136 G a nn Code Blue IP1500 2500 User Guide 7 Reset to Defaults The IP 1500 2500 speakerphone can be reset by following the steps below Use the 7 pin reset plug sent with your order in order to perform a full reset 4 amp 5 Long Reset Hard Reset sets everything back to default 2 amp 3 Short Reset Resets network configuration 1 Unplug the RJ45 from the PoE switch port 2 Unplug button and disconnect the LED harness 3 Short the appropriate 2 pins together for short or long reset see pic below 4 Plug the RJ 45 back into the PoE switch port 5 Upon hearing two short beeps unit has been reset 6 Wait 10 seconds for phone to reboot 7 Unplug power source 8 Remove the jumper and reconnect the buttons 9 Reconnect 7 pin harness 10 Reconnect PoE The Reset is now complete PoE Ere EC Jet Claes 0 Mig Part SPNOZSXCN RC Shorting Shunt 2mm 5 Hard Reset on 4 Hard Reset 3 Network cfg Reset 2 Network cfg Reset Code Blue 259 Hedcor Street Holl
17. period or toggled for a specific time period upon the operator s request IP 1500 g PoE Ethernet Ground Co LED Grn pos UNUSED Btn 1 Data wire LED Red pos Button 1 Red 3 3 Button LED Connector T SPST NO 1 Form A Contact Max Volts 250 AC 30 DC 3 amps RoHs Compliant Code Blue 259 Hedcor Street Holland MI 49423 USA e 800 205 7186 www codeblue com a LL Faceplate LED Tri Color Common terminal bus page 7 of 21 GU 136 G LE Code Blue IP1500 2500 User Guide 4 3 Wiring Diagram IP2500 2501 The IP2500 2501 has one PoE LAN port for network connectivity and one normally open auxiliary output relay for triggering devices such as a LED beacon strobe camera preset activation inputs gate control or third party controllers The relay can be programmed to hold the relay closed for the duration of the call for a specific time period or toggled for a specific time period upon the operator s request The IP2500 2501 also has the option of an additional button for non emergency calls MIC LED PCB Connector side TE fia common terminal bus su common Positive terminal bus Ground co LED Grn pos Btn 2 Data wire UNUSED Btn 1 Data wire LED Red pos NS eam Button LED Connector Gnd Btn 1 amp 2 Bik wire amp Led Blk SPST NO 1 Form A Contact Max Volts 250 AC 30 DC 3 amps RoHs Compliant
18. pyright 2013 Code Blue Code Blue 259 Hedcor Street Holland MI 49423 USA 800 205 7186 www codeblue com page 15 of 21 GU 136 G Code Blue IP1500 2500 y User Guide 6 4 Network Setup VLAN Configuration The IP1500 2500 speakerphone is capable of performing IEEE 802 1Q frame tagging and user priority settings 1 Click on the Network menu item under Network Setup see far left hand column 2 Then click on the VLAN Enabled check box in the VLAN section and select your desired VLAN ID and User Priority 3 Once you have entered your settings click on Save Changes Note If your PC cannot access the new VLAN you will have to correct this problem before continu ing configuration as you will lose access to the IP1500 2500 If you wish to disable VLAN support and cannot reach the IP1500 2500 on its configured VLAN factory reset the unit to clear network configuration IP1500 2500 Configuration Network Setup Session General Auto logout 07 52 Host 1721 10061 Domain Connection Type Dynamic IP Static IP Static IP Address Address 0 0 0 0 Mask 255 255 0 0 Account 1 Default Router 0000 Account 2 DNS Primary 0 0 0 0 Media Advanced DNS Secondary 0 0 0 0 System DNS Tertiary 0 0 0 0 Administration Date Time Upgrade Firmware MTU Size advanced 1500 Code Blue Configuration VLAN Batch Configuration VLAN Enabled Numbers i ID 4 value 0 to 4094 Rec