1. cord that didn t ship with the equipment ensure that it is rated for the voltage and current labeled on the equipment s electrical ratings label The voltage rating on the cord should be higher than the one listed on the equipment s ratings label m Observe all precautions and warnings attached to the equipment If you dont intend on using the equipment for a long time disconnect it from the power outlet to prevent being dam aged by transient over voltage E Keep all liquids away from the equipment to minimize the risk of accidental spillage Liquid spilled on to the power supply or on other hardware may cause damage fire or electrical shock m Only qualified service personnel should open the chassis Opening it yourself could damage the equipment and invali date its warranty m If any part of the equipment becomes damaged or stops functioning have it checked by qualified service personnel What the warranty does not cover m Any product on which the serial number has been defaced modified or removed m Damage deterioration or malfunction resulting from O Accident misuse neglect fire water lightning or other acts of nature unauthorized product modification or failure to follow instructions supplied with the product L Repair or attempted repair by anyone not authorized by us L Any damage of the product due to shipment O Removal or installation of the product L Causes external to the product such as electric power fluc
2. IP KVM list Model No Combo Cat6 KVM UIP 802 UIP 1602 UIP 3202 Combo DB 15 KVM P 802 P 1602 USB Hub DB 15 KVM P 802H IP 1602H Matrix Cat6 KVM MU IP1613 MU IP1624 MU IP3213 MU IP3224 Matrix DB 15 KVM M IP813 M IP824 M IP 1613 M IP 1624 UM IPS 01 Q212V8 No of Combo KVM port No of IP port come with 1 x Multi port 16 port 32 port 16 port 16 port 32 port 2 dual 8 port emt 2 dual 16 port 2 dual P 3 www austin hughes com lt 2 2 gt IPS 01 free PDU management software specially designed for IP KVM CyberView IP KVM allows the user to manage servers amp PDUs together Web Based GUI IPS 01 is applicable to the CyberView Connection only No software application required to be installed on the PC A Skip the above step if the IP KVM has been already login Step 1 Open Internet Explorer I E version 6 0 or above Authenticate Username and Password Step 2 Enter the IP KVM address into the address bar Username ssid For Single IP KVM model such as UIP 1602 http 192 168 1 22 Password 0 O For Dual IP KVM model such as MU IP3224 http 192 168 1 22 for 1st IP amp http 192 168 1 23 for 2nd IP Step 3 Enter username default is super amp password default is pass A The setting is enough for intranet If the users access KVM GUI via internet please ask MIS for assistance and download IP KVM user manual from the link
3. Infra Power Intelligent Remote Power Management User Manual IPS 01 IP KVM GUI Software MTS switched PDU MT monitored PDU tie Lae Designed and manufactured by Austin Hughes UM IPS 01 Q212V8 www austin hughes com Legal Information First English printing October 2002 Information in this document has been carefully checked for accuracy however no guarantee is given to the correctness of the contents The information in this document is subject to change without notice We are not liable for any injury or loss that results from the use of this equipment Safety Instructions Please read all of these instructions carefully before you use the device Save this manual for future reference m Unplug equipment before cleaning Don t use liquid or spray detergent use a moist cloth E Keep equipment away from excessive humidity and heat Preferably keep it in an air conditioned environment with temperatures not exceeding 40 Celsius 104 Fahrenheit m When installing place the equipment on a sturdy level surface to prevent it from accidentally falling and causing dam age to other equipment or injury to persons nearby E When the equipment is in an open position do not cover block or in any way obstruct the gap between it and the power supply Proper air convection is necessary to keep it from overheating E Arrange the equipments power cord in such a way that others won t trip or fall over it m If you are using a power
4. ding to the table UM IPS 01 Q212V8 P 1 www austin hughes com 1st level PDU 2nd level PDU 3rd level PDU InfraPower InfraPower InfraPower CAT 5 6 CAT 5 6 cable cable Up to 20 meters Up to 20 meters i To LINK port of next PDU Up to 16 levels amBEEEE aco Cas a RBSAEEE 123 45 6 7 8 123 45 6 7 8 123 45 6 7 8 Dip switch setting Dip switch setting Dip switch setting Meter display setting Using the dip switch no 5 amp 7 to setup each PDU meter display as below Current display Audio alarm Using the dip switch no 6 to setup each PDU audio alarm as below Dip switch 6 On Disable UM IPS 01 Q212V8 P 2 www austin hughes com To Multi port To LINK port of the 1st PDU 1st level PDU CyberView Matrix IP KVM TTVITIILICTiLiLriiritg4 LARA A Other band IP KVM can NOT connect InfraPower PDU A Each RJ 45 Multi port connect max 16 pcs of InfraPower PDU 16 pcs InfraPower PDU x 2 for dual Multi port 2nd level PDU 3rd level PDU InfraPower CAT 5 6 InfraPower CAT 5 6 InfraPower cable cable LINK OUT LINK OUT LINK OUT W0 Co gt CURRENT A Up to 20 meters CURRENT A Up to 20 meters R 225 i To LINK port of next PDU Up to 16 levels m Please refer dip switch setting on P 1 2 for different level PDUs For details please visit the link below www austin hughes com support usermanual infrapower UM IPS 01 pdf CyberView
5. prior notice and assumes no responsibility for any error which may appear in this publication All brand names logo and registered trademarks are properties of their respective owners Copyright 2011 Austin Hughes Electronics Ltd All rights reserved UM IPS 01 Q212V8 www austin hughes com Unpacking The equipment comes with the standard parts shown on the package contents Check and make sure they are included and in good condition If anything is missing or damage contact the supplier immediately Package contents 1 Vertical MTS MT PDU x 1 VMS mounting screw set of 2 or 3 VMB mounting bracket set M6x2 M6nutx2 2 3 sets OR 2 Rackmount MTS MT PDU x 1 Power ON E Connect the PDU into an appropriately rated receptacle m When the PDU is power on the LED display will light up That means all outlets are activated m Keep the equipments in the power off position until it is plugged into the PDU A Don t exceed the outlet branch or phase limitations UM IPS 01 Q212V8 www austin hughes com lt 1 1 gt PDU meter setting amp cascade Infra Power AT foam DIP Switch lt ON gt DIP Switch lt OFF gt PDU cascade port Current display 12345678 ON Dip switch Reset button m For rackmount PDU on the front panel left on the rear panel Cascaded PDUs setting Using the dip switch no 1 2 3 4 amp 8 to setup each PDU level acor
6. tuation or failure O Use of supplies or parts not meeting our specifications O Normal wear and tear L Any other causes which does not relate to a product defect E Removal installation and set up service charges Regulatory Notices Federal Communications Commission FCC This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference in a residential instal lation Any changes or modifications made to this equipment may void the user s authority to operate this equipment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures mM Re position or relocate the receiving antenna Mm Increase the separation between the equipment and receiver E Connect the equipment into an outlet on a circuit different from that to which the receiver is connected The company reserves the right to modify product specifications without
7. w Geer save the changes Gerais refresh the PDU information The company reserves the right to modify product specifications without prior notice and assumes no responsibility for any error which may appear in this publication All brand names logo and registered trademarks are properties of their respective owners Copyright 2012 Austin Hughes Electronics Ltd All rights reserved UM IPS 01 Q212V8 PS www austin hughes com
8. www austin hughes com support usermanual cyberview UM CV IP pdf To access the PDU GUI please select Remote Power gt Start Service gt Apply Remote Power Start the Remote Power service RS485 UM IPS 01 Q212V8 P 4 www austin hughes com lt Overview gt e Aggregate current on the PDU Status of all connected PDUs Latest loading on each circuit of PDU e Alarm threshold setup Data refresh every 10 seconds Disable Refresh during data input PDU Overview Auto Refresh C Circuit B Model Enclosure Status Alarm Max Load Alam Wi8C413 164 MT New location Normal I 4 A s Wi8C413 164 MT New location Normal 13 g A A WIGC13 164 MT New location Normal Eko sA W18012 164 MT New location Normal 13 4 Gmm save the changes lt Control gt e On Off status of each outlet Remote on off outlet MTS switched PDU only Data refresh every 10 seconds Rename outlet device amp PDU location Disable Refresh during data input POU Control Levet 2 x Enclosure Few cation Auto Refresh E Status i Normal Loading 000 460 AlMax Outet Name Power Switch Name Power switch 0 DewieMeme CDN 7 3 eiae ON 7 Deiotime 2 ON a Dei lf ON F Derien 3 ON 3 Devise Name 15 ON j Device Emme f DeviceMame_16 ON EJ fo encehamne 17 TevieMane z DevieeName_ 9 o eieae 20 GE show the specified PDU status Select the PDU Level gt Vie