Brocade VDX 8770-8 Hardware Reference Manual, August 2013
Contents
1. 1 Linecards L1 through L4 left to right 6 Intake Vent Cable management comb 7 Management modules MM1 and MM2 left to right 3 Switch fabric modules S1 through S6 odd numbers 8 Power supplies 1 through 8 1 through 4 above above even numbers below left to right left to right 5 through 8 below left to right Line cards L5 through L8 left to right 9 ESD jack 5 Mounting flanges FIGURE 1 Port side of the Brocade VDX 8770 8 sample configuration Brocade VDX 8770 8 Hardware Reference Manual 53 1002564 03 1 Brocade VDX 8770 8 hardware components Nonport side of the Brocade VDX 8770 8 Figure 2 shows a sample configuration of the nonport side view of the Brocade VDX 8770 8
2. FIGURE 15 Removal and replacement of the switch fabric module Replacing a switch fabric module Complete the following steps to insert the SFM 1 2 3 4 Unpack the new SFM and remove it from the anti static bag Inspect the module for damage Remove the protective caps from the backplane connectors Unscrew the power enable pin pull it outward and move the slider toward the center of the module face Open the ejectors on the new SFM by rotating them toward the center of the module face Orient the switch fabric module so that the ejectors are toward you Align the module pan with the guides in the slot The first SFM ashould be installed in slot S3 Push the SFM firmly into the slot Close the ejectors by rotating them away from the center of the SFM The levering action of the ejectors seats the module in the slot Brocade VDX 8770 8 Hardware Reference Manual 53 1002564 03 Power supply removal and replacement 5 9 Tighten the captive screws using the Phillips screwdriver 10 Pull out the power enable pin and move the slider all the way down 11 Screw in the power enable pin 12 Tighten the screws on the slider Power supply removal and replacement Use this procedure to remove and replace a power supply NOTE Depending on the module configuration of the chas
3. 1 PowerLED 2 Status LED FIGURE 8 Switch fabric module Table 11 describes the switch fabric module LED patterns and the recommended actions for those patterns TABLE 11 Switch fabric module LED descriptions LED purpose Color Status Recommended action Power No light LED is off SFM is not on Ensure that the SFM is firmly seated and the on off switch is turned on l slider is covering the captive screw Steady green SFM is on No action required Brocade VDX 8770 8 Hardware Reference Manual 53 1002564 03 TABLE 11 Switch fabric module LED descriptions Continued LED purpose Color Status LED No light LED is off Determining the status of a power supply 4 Status SFM is healthy or is not powered on Recommended action Verify that the power LED is on D Steady amber SFM is faulty Ensure that the SFM is firmly seated and check the status by entering the show slot command If the LED remains amber consult the Brocade switch supplier Slow flashing amber on 2 seconds then off 2 seconds SFM is not seated correctly of is faulty Pull the SFM out and reseat it If the LED remains amber replace the module Fast flashing amber on 1 2 second then off 1 2 second Environmental range exceeded Determining the status of a power supply Complete t
4. FIGURE 12 Removal and replacement of a line card 48x10G card shown Replacing a line card For this procedure refer to Figure 12 Complete this procedure to insert a new line card Brocade VDX 8770 8 Hardware Reference Manual 51 53 1002564 03 5 Management module removal and replacement Unpack the new line card and remove it from the anti static bag Inspect the module for damage Remove the protective covers from the backplane connectors Orient the line card so that the ports are at the front of the switch 9v ele ep Open the ejectors by rotating them toward the center of the line card face and align the flat side of the line card inside the top and bottom rail guides in the slot Line cards can be inserted in any of the slots labelled L1 through L8 6 Slide the line card all the way into the slot Close the ejectors by rotating them away from the center of the line card The levering action of the ejectors seats the line card in the slot 8 Tighten the captive screws using the Phillips screwdriver Management module removal and replacement This section describes how to remove and replace a management module MM Each Brocade VDX 8710 8 chassis can have one or two management modules They reside in slots M1 and M2 There must be at least one MM installed for the chassis to operate Time and items required The replacement procedure for the MM takes approximately 30
5. SERVICE B 1 Status LED 2 Power LED 3 Active LED 4 Console port Serial FIGURE 7 Management module 5 Ethernet port Mgmt IP 6 USB port 7 Ethernet port Service IP Table 10 describes the management module LED patterns and the recommended actions for those patterns TABLE 10 Management module LED descriptions LED purpose Color Status Recommended action Power Steady green MM is powered on No action required b No light LED is off MM is not powered on Ensure that the module is firmly seated and has power Status No light LED is off MM is either healthy or does Verify that the power LED is on not have power e Steady amber MM requires attention or is If the LED remains amber the still booting up module is faulty Consult the Brocade VDX 8770 8 supplier Active Steady blue Module is the active MM No action required No light LED is off Module is booting up negotiating to be the active MM or is the standby MM No action required Ethernet Steady green Ethernet link speed is 1000 No action required management Mbps 1 Gbps link upper F gt F left No light LED is off There is no link or link speed is No action required 10 100 Mbps Ethernet Blinking green Ethernet li
6. lllsuuss 53 Replacing a management module llsususlss 54 Switch fabric module removal and replacement 54 Time and items required llli eee 54 Removing a switch fabric module 0000e eee 55 Replacing a switch fabric module 00 0000 56 Power supply removal and replacement naan nn annen nnne 57 Time and items required 2 cee eee 57 Removing an AC power Supp 57 Replacing an AC power supply 00 cece eee eens 58 Removing a DC power supply 0000 e eee ee eee 59 Replacing a DC power supply 0 0000 eee eee eee 59 Fan removal and replacement 0c eee eee e ee eee 60 Time and items required 2 0 cee 60 Removing a fal ist anas ian emere Rea 60 Replacing a fan assembly 02 000 cee eee eee eee 61 Air filter removal and replacement 62 Time and items required 2 cee eee 63 Removing an air filter 63 Replacing an air filter llle lesse 63 Module filler panel removal and replacement 63 Removing a filler panel oooooooocoooorcorr o 64 Replacing a filler panel 20 0 0 cece eee eee 64 Chassis ID card removal and repnlacement ann nnnnnaa 64 SFP transceiver removal and renlacement nan nnnnnnnna 65 Time and items required 2 ee eee 65 Removing a transceiver 1 0 eee eee 66 Replacing a transceiver 2 0 2 cece eee 67 QSFP transceiver removal
7. ooooooooooo 16 e PortpnberiB arar NEE EE AAA 17 e Providing power to the Brocade VDX 8770 8 00 cece sss 18 Time and items required You can set up and install the Brocade VDX 8770 8 in the following ways e As a standalone unit on a flat surface e nafour post rack e natwo post telecommunications Telco rack This manual describes how to set up the Brocade VDX 8770 8 as a standalone unit For rack mount installation instructions refer to the manual that comes with the separately ordered rack kit Table 2 describes the main installation and setup tasks the estimated time required for each and the items required to complete the task based on a fully populated Brocade VDX 8770 8 384 10 GbE ports Configurations with fewer ports require less time These time estimates assume a prepared installation site and appropriate power and network connectivity A DANGER Brocade VDX 8770 8 Hardware Reference Manual 53 1002564 03 The procedures in this manual are for qualified service personnel TABLE 2 Installation tasks time and items required Installation task Time estimate Items required Site preparation and unpacking Brocade 30 minutes 2 Phillips screwdriver VDX 8770 8 Pallet jack Hydraulic lift or assisted lift able to raise to a minimum of 140 cm 55 in with a minimum capacity of 113 kg 250 Ib A fully loaded version of the Brocade VDX 8770 8 weighs 165 56 kg 365 Ibs 2 Items included w
8. 5 Power supply removal and replacement 5 Push down on the handle to eject the power supply 6 Graspthe handle and pull sliding the power supply from the chassis and supporting the power supply from beneath as you remove it FIGURE 16 Removal and replacement of the power supply Replacing an AC power supply If you are not replacing the power supply insert a filler panel into the slot For the following procedure refer to Figure 16 To replace a power supply complete the following steps A DANGER High Touch Current Earth connection is essential before connecting the power supply 1 Unpack the new power supply and remove it from the anti static bag 2 Inspect the power supply for damage 58 Brocade VDX 8770 8 Hardware Reference Manual 53 1002564 03 oa 25 o Power supply removal and replacement 5 Ensure that the handle of the replacement power supply is pushed down Insert the power supply into the slot Rotate the handle upward to fully seat the power supply Tighten the captive screw Removing a DC power supply To remove a DC power supply complete the following steps 1 Ge Bos If the Brocade VDX 8770 8 is operating and will continue to operate during the replacement check the power LEDs to verify that the minimum number of power supplies is functioning Refer to Table 3 and Table 4 i
9. 79 C cable management comb replacing 48 cables attach SFP 32 managing 34 Canadian requirement 80 caution statements translated 85 CE statement 79 certifications 71 78 80 chassis hardware components 2 weight and size 72 chassis ID card see CID card chassis name customizing 27 China RoHS 81 CID card 64 determining status 46 recovery options 65 CID recovery tool 64 classes of service 71 clock set command 29 clock timezone command 28 29 Brocade VDX 8770 8 Hardware Reference Manual 53 1002564 03 command clock set 29 clock timezone 28 29 configure terminal 25 copy 31 copy running config startup config 30 ip address 25 ip gateway address 25 logout 26 no ntp server 29 ntp server 28 29 show chassis 31 44 show clock 30 show environment 44 show environment power 43 show fabric all 31 33 show interface 31 33 show interface management 40 show license 30 show license id 30 show linecard 35 show mm 40 show ntp status 29 show running config 26 show sfm 41 show slots 35 41 show system 43 45 switch attributes 27 username 25 ves rbridge id 24 compliance environmental regulation 81 configuration 22 backup 31 date and time 28 persist 30 switch IP address 25 verify 31 configure terminal command 25 connecting Ethernet devices 32 workstations servers routers 32 copy command 31 copy running config startup config co
10. TABLE 14 Output for show environment fan command Output Explanation OK Fan is functioning correctly at the displayed speed RPM absent Fan is not present Could also mean that the fan is improperly seated below minimum Fan is present but rotating too slowly or stopped above maximum Fan is rotating too quickly unknown Unknown fan unit installed faulty Fan has exceeded hardware tolerance and has stopped In this case the last known fan speed is displayed Could also mean that the fan is improperly seated Brocade VDX 8770 8 Hardware Reference Manual 45 53 1002564 03 4 Determining the status of a CID card For absent or faulty indications contact the Brocade VDX 8770 8 supplier to order replacement parts You may also want to do this if the indication is below minimum or above maximum Table 15 describes the LED patterns for the fan TABLE 15 Fan LED descriptions LED purpose Color Status Recommended action OK No light Fan does not have power Ensure that the fan is firmly LED is off seated and has power Steady green Fan has power No action required Fault No light Fan is either healthy or Ensure that the fan has power LED is off does not have power Steady amber Fan has a failure full or Replace the fan partial Determining the status of a CID card 46 Regular validation tests are run by the system comparing the CID cards to each other If the information is identical then the c
11. The factory configured default accounts on the switch are admin and user Use the default administrative account as shown in Table 8 to log in to the switch for the first time and to perform the basic configuration tasks The user account is read only and used primarily for system monitoring TABLE 8 Default administrative account names and passwords Account type Login name Password Administrative admin password User account read only user password Brocade VDX 8770 8 Hardware Reference Manual 53 1002564 03 Configuring the IP addresses 3 Changing the default account passwords When you change the default account password after you log in for the first time only the default password rule is in effect The rule specifies a minimum password length of eight characters For advanced user and role management including setting password rules refer to the Security chapter of the Brocade Network OS Administrator s Guide NOTE Passwords can be 8 to 40 characters long They must begin with an alphabetic character They can include numeric characters the period and the underscore _ only Passwords are case sensitive and they are not displayed when you enter them on the command line The available roles are admin and user For more information on passwords refer to the Brocade Network OS Administrator s Guide 1 Enterthe configure terminal command to enter global configuration mode 2 Enterthe username command followed by the a
12. Using the rack mount instructions install the rack components in the rack and mounting flanges on the switch The rack mount kit and instructions are shipped separately from the switch 4 Remove the accessory kit cardboard box packing foam and antistatic plastic from the switch and set them aside Remove the foam inserts around the base of the switch Use a lift to raise the switch to the correct level If installing the switch in a rack follow the instructions provided by the rack kit manufacturer If applicable lock the wheels of the lift 8 Ensure that the switch is oriented so that the port side front has access to intake air Brocade VDX 8770 8 Hardware Reference Manual 53 1002564 03 Port numbering 2 9 Gently slide the switch onto the final installation surface ensuring that it remains supported during the transfer 10 Before you apply power to the switch you can install the MM SFM and line card modules as well as power supplies to speed up your installation Port numbering The Brocade VDX 8770 8 uses the following port numbering method e 12x40G line card module Ports are numbered from 1 through 12 from from top to bottom when installed in the switch Refer to Figure 3 gol o 9e o so oltolzezol lto ao uojoo 60 FIGURE 3 12x40G line card Brocade VDX 8770 8 Hardware Reference Manual 17 53 1002564 03 2 Providing power to the Brocade VDX 8770 8 e 48x1G and 48x10G
13. finit les normes et r gulations pour les cordons d alimentation dans votre pays Cette marque vous assure que vous pouvez utiliser le cordon d alimentation avec le dispositif en toute s curit PELIGRO Si la instalaci n requiere un cord n de corriente distinto al que se ha suministrado con el instrumento verifique que usa un cord n de corriente que venga con la marca de la agencia de seguridad que defina las regulaciones para cordones de corriente en su pa s Esta marca ser su garant a de que el cord n de corriente puede ser utilizado con seguridad con el instrumento DANGER High Touch Current Earth connection essential before connecting supply Brocade VDX 8770 8 GEFAHR Hoher Ableitstrom Vor Anschluss ans Netz Schutzerdung herstellen Brocade VDX 8770 8 DANGER Courant de fuite lev Mise la terre obligatoire avant la connexion de l alimentation Brocade VDX 8770 8 PELIGRO Alta tensi n al tacto La conexi n a tierra es esencial antes de conectar la alimentaci n Brocade VDX 8770 8 Brocade VDX 8770 8 Hardware Reference Manual 89 53 1002564 03 90 B Danger notices Brocade VDX 8770 8 Hardware Reference Manual 53 1002564 03 Index A accessing NTP server 29 airflow requirement 15 altitude requirement 15 ambient temperature requirement 15 B back up configuration 31 Brocade ISLs 72 Brocade trunking 34 72 BSMI statement Taiwan
14. local clock 29 LOCL 29 logging date and time 28 logout command 26 M management module 71 management module see MM managing cables 34 media types 72 MM determining status 40 LEDs 40 replacing 52 modules weight 72 N NEBS GR 1089 requirements 77 network connectivity testing 32 no ntp server command 29 notices safety 77 NTP server access 29 ntp server command 28 29 numbering port 17 P persist configuration 30 port Ethernet 71 numbering 17 power cord notice Japan DENAN 76 types 74 power cords listed by type and country 74 power requirements 13 power supply LEDs 44 replacing 57 status 43 power providing 18 Brocade VDX 8770 8 Hardware Reference Manual 53 1002564 03 Q QSFP transceivers installing 33 replacing 67 quad small form factor pluggable transceivers see QSFP transceivers R rack space requirement 12 recovering CID card 64 recovery options CID recovery tool 65 regulatory compliance 78 removing SFM 55 replacing a power supply 57 replacing fan 60 replacing filler panel 62 63 replacing MM 52 replacing QSFP transceivers 67 replacing SFM 56 replacing transceivers 65 requirements NEBS GR 1089 77 running configuration backing up 31 S safety guidelines 12 safety notices 77 SCP backing up via 31 serial connection establishing 22 serial port logout 26 setting date and time 28 static IP address 25 time zone 29 SFM
15. section of the Network OS Administrator s Guide Medium flashing green on 1 seconds then off 1 seconds Beaconing used to identify specific ports No action required Fast flashing green on 1 2 second the off 1 2 second Internal loopback diagnostic In diagnostic mode Will return to regular mode when diagnostic is finished Brocade VDX 8770 8 Hardware Reference Manual 53 1002564 03 Determining the status of a management module TABLE 9 LED purpose Color 40GbE QSFP Port Status 12x40G line card in 40G No light LED is off Line card LED descriptions Continued Status There is no QSFP transceiver installed A Recommended action Verify that the power LED is on ensure the transceiver is fully seated or install the transceiver mode Steady green The port is online but has no traffic No action required Flickering green The port is online with traffic flowing htrough the port No action required Steady amber The port is receiving light but it is not online yet Reset the port by issuing a shutdown and no shutdown sequence on the port Slow flashing amber on 2 seconds then off 2 seconds The port is disabled Enable the port by issuing a no shutdown command Fast flashing amber on 1 4 second the off 1 4 second Slow flashing green on 2 seconds then off 2 seconds Medium flashing green on 1 seconds then off 1
16. which provides redundancy in case one of the circuits fails VORSICHT Es empfiehlt sich die Installation eines separaten Stromkreiszweiges f r jede Wechselstrom Elektroschnur als Redundanz im Fall des Ausfalls eines Stromkreises MISE EN GARDE Utilisez un circuit de d rivation diff rent pour chaque cordon d alimentation C A Ainsi il y aura un circuit redondant en cas de panne d un des circuits PRECAUCI N Use un circuito derivado separado para cada cord n de alimentaci n de CA con lo que se proporcionar redundancia en caso de que uno de los circuitos falle Brocade VDX 8770 8 Hardware Reference Manual 53 1002564 03 CAUTION Danger notices B All devices with AC power sources are intended for installation in restricted access areas only A restricted access area is a location where access can be gained only by service personnel through the use of a special tool lock and key or other means of security VORSICHT Alle Ger te mit Wechselstromquellen sind nur zur Installation in Sperrbereichen bestimmt Ein Sperrbereich ist ein Ort zu dem nur Wartungspersonal mit einem Spezialwerkzeug Schloss und Schl ssel oder einer anderen Schutzvorrichtung Zugang hat MISE EN GARDE Tous les quipements dot s de sources d alimentation lectrique secteur sont destin s tre install s uniquement dans des zones acc s r glement Une zone acc s r glement est une zone dont l acc s n est p
17. 1804 5 ft 550 m 1804 5 ft 550 m 1804 5 ft 10 km 6 2 mi 1 GbE Copper SFP Copper Copper 100 m 328 1 ft 10 GbE USR 850 50 100 m 984 3 ft 10 GbE SR 850 50 300 m 328 1 ft 10 GbE LR 1310 10 km 6 2 mi 10 GbE twinax Copper 1m 3 3 ft 3 m 9 8 ft 5 m 16 4 ft 40 GbE 100 m 984 3 ft The ports meet all required safety standards For a listing of these standards refer to Regulatory compliance Brocade VDX 8770 8 Hardware Reference Manual 73 53 1002564 03 A Power cords Power cords The types of power cords provided with the Brocade VDX 8770 8 are specific to the country where it is installed For each of the types of power cords in Table 23 the end that connects to the Brocade VDX 8770 8 has an IEC 60320 C19 cable connector The AC power receptacles on each power supply are equipped with IEC 60320 C20 power connectors In order to connect to a power strip already installed in a cabinet the C20 20A 250V 12 AWG power cord is required To order a power cord contact your Brocade VDX 8770 8 supplier TABLE 23 Power cord types international Country Plug style NEMA 5 20P NEMA L6 20 CEE 7 7 BS 1363A AS 3112 IEC 60309 C20 125V only USA Canada Schuko Australia New 32A 6h 230V 20A 250V USA Canada Mexico other Continental Zealand 12 AWG Mexico other locations Europe connect to locations in cabinet power strip only
18. 2nd Ed or S mark latest Russia IEC60950 1 2nd Edor 51318 22 99 and GOST mark GOST mark latest 51318 24 99 or latest Korea KN22 and KN24 KC mark Class A China PS only GB4943 2001 and GB17625 1 2003 or CCC logo CCC logo GB9254 1998 orlatest latest Taiwan PS only CNS 14336 94 or CNS 13438 95 or BSMI mark BSMI mark latest latest Environmental regulation compliance This section describes the China RoHS environmental regulatory compliance requirements for the Brocade VDX 8770 8 China RoHS The contents included in this section are per the requirements of the People s Republic of China Management Methods for Controlling Pollution by Electronic Information products HESS SETA HA E RoHS AST ALES S A AS aE OE ERE Cof AR ERZME BU Environmental Protection Use Period EPUP Disclaimer In no event do the EPUP logos shown on the product and FRUs alter or expand that warranty that Brocade provides with respect to its products as set forth in the applicable contract between Brocade and its customer Brocade hereby disclaims all other warranties and representations with respect to the information contained in this document including the implied warranties of merchantability fitness for a particular purposes and non infringement The EPUP assumes that the product will be used under normal conditions in accordance with the operating manual of the product Brocade VDX 8770 8 Hardware Ref
19. 8 Hardware Reference Manual 53 1002564 03 Line card removal and replacement 5 FIGURE 11 Removal and replacement of the cable management comb Replacing a cable management comb Complete the following steps to replace the cable management comb 1 Position and tighten the four 4 screws to secure the new comb to the chassis 2 Arrange the cables in the comb Line card removal and replacement This section describes how to remove and replace line cards It does not cover the management modules or the switch fabric modules It covers the removal and replacement of line cards of the same type If you need to replace a line card with a line card of a different type please consult the Brocade Network OS Administrator s Guide Brocade VDX 8770 8 Hardware Reference Manual 49 53 1002564 03 50 5 Line card removal and replacement ATTENTION Any slot that is not occupied by a line card should be occupied by a filler panel to ensure correct cooling of the chassis and protection from dust Line card slots are numbered from L1 through L8 from left to right when facing the port side of the Brocade VDX 8770 8 They are in two groups of four L1 through L4 on the left and L5 through L8 on the right NOTE The 48x1G 48x10G and 12x40G line cards are compatible with the Brocade VDX 8770 8 Time
20. 8 Hardware Reference Manual 53 1002564 03 Preparing for the Brocade VDX 8770 8 installation 2 e Grounded outlets installed by a licensed electrician and compatible with the power cords A DANGER If the installation requires a different power cord than the one supplied with the switch make sure you use a power cord displaying the mark of the safety agency that defines the regulations for power cords in your country The mark is your assurance that the power cord can be used safely with the switch 3 Plan for cable management before installing the switch Cables can be managed in a variety of ways such as by routing cables below the switch to either side of the switch through cable channels on the sides of the rack or by using patch panels 4 Ensurethatthe following items are available for configuration of the Brocade VDX 8770 8 e Workstation with an installed terminal emulator such as HyperTerminal Console serial cable provided Ethernet cables not provided e Either access to an FTP server or a Brocade USB device for backing up the switch configuration or collecting supportsave output data optional Transceivers copper and optical and compatible cables and direct attach cables if needed 5 Brocade strongly recommends that devices be installed in environments that have minimal dust and airborne contaminants 6 Ensure that the air intake and exhaust vents have a minimum of 5 1 cm 2 in of airspace En
21. A RISA SIS IES LS H z CL R 0 0 O O HH Ee SE SIS A KE Ter Za CHL HI rem COR HOHER o Ll SO alle Cee SOOO e O o ei 6 ER E Sa El D f O Z CS A e ZE E ole SIS O SR SIS EE 22929 9 Hill RES SOO EE ERE RS OOO ASEH BOE SS P eB Eso ea tas SS Ero eR i ERO es Le HE ESOS ROSES EHE HE OS SER SAID DOSIS SAO SOSA O REVERS PERSIAN SAR EE SSA PESE KR OR EERES ORO Ch CR ROSSO O ISO OBEN COTO Ras DEE KEE e eos OSOS o SISI BESOS OO OSOS IA CNEEECH IS OS SISSI A SISSI CEET ESOS CHO KEE DE EE EE E REEL SES He E KEE CERN o ee E SN eebe Ce Ch LC SEO EU KEE SSI OSIRIS ere Seer cased aSelo KEN E RR VO SISI ME ade i o 00s BOR e SEO a ee En Ie CL SS Kee ENEE ISR ISS e E ER E KH EECHER II SIR SID SS SSA SISSI SISI IIS ESA SISSI SOS ERR RREA ESOO O RETRE SSA IS SES PS IS ISS i RTS IS SSA IROHERERS e SIS DIS HIT SI O o LR SS alle Do POR e mm zm wm O AGENCY LABEL THIS DEVICE HAS NOT BEEN AUTHORIZED AS REQUIRE EY THE RULES OF THE FEDERAL CONMUNICATI OBTAINED PROTOTYPE SYSTEMS FOR EVALUATION AND QUALIFICATION PURPOSE ONLY 6 1 Fan assemblies 1 and 2 left to right 2 Fanassemblies 3 and 4 left to right FIGURE 2 ONS COMISSION THIS DEVICE IS NOT AND MAY N
22. could take up to eight minutes depending on chassis configuration and traffic load Software features The following is a partial list of the features supported in the software See the Brocade Network OS Administrator s Guide for details on software and supported features Brocade VDX 8770 8 Hardware Reference Manual 53 1002564 03 Layer 2 L2 data forwarding MAC learning and aging Brocade Trunking Priority Flow Control PFC Enhanced Transmission Selection ETS Terminal Access Controller Access Control System Plus TACACS Link Aggregation Control Protocol LACP Link Layer Discovery Protocol Data Center Bridging eXchange LLDP DCBX 802 1x Brocade Link Discovery Protocol BLDP Layer 3 Open Shortest Path First OSPF v2 Static routes Virtual Router Redundancy Protocol VRRP and VRRP E 1 Software features e Internet Group Management Protocol IGMP v1 and v2 and snooping e Address Resolution Protocol ARP Virtualization e Automatic Migration of Port Profiles AMPP e Support for VLAN QoS security and FCoE port profiles e VMware vCenter and Brocade NOS integration FCoE Pause Frames Tx and Rx e Priority Flow Control PFC e Enhanced Transmission Selection ETS e End to end multi hop FCoE with proper licensing e FCoE and FC zoning and RSCN suppression name server based zoning e FIP version 1 e FC Fabric Services for FCoE VN port devices e Multipath support for FCoE traffic e F
23. determining status 41 LEDs 42 removing 55 replacing 54 56 SFPs 32 shock requirement 15 show chassis command 31 44 show clock command 30 show environment command 44 93 show environment power command 43 show fabric all command 31 33 show interface command 31 33 show interface management command 40 show license command 30 show license id command 30 show linecard command 35 show mm command 40 show ntp status command 29 show running config command 26 show sfm command 41 show slots command 35 41 show system command 43 45 site planning 12 size and weight chassis 72 small form factor pluggable transceivers see SFPs specifications general 71 startup configuration backing up 31 static IP address IPv4 25 IPv6 26 status CID card 46 fan 44 line card 35 MM 40 power supply 43 SFM 41 straight through cable 32 supported optics 73 switch fabric module see SFM switch IP address 25 static 25 switch name See host name switch connect to 24 switch attributes command 27 synchronize local time using NTP 29 system architecture 71 system processor 71 T tasks installation 9 terminal emulator configuring 23 testing network connectivity 32 time and date 28 94 time zone explanation 28 setting 29 tool extraction transceivers 65 trademarks xvi transceivers extraction tool 65 replacing 65 supported types 11 trunk group 34 U USB device backing
24. est accessible que par le personnel d entretien l aide d un outil verrou ou cl concus cet effet ou de tout autre accessoire de s curit et qui est contr l par l autorit responsable de ce local PRECAUCI N Todos aquellos dispositivos con fuentes de alimentaci n de CC Brocade VDX 8770 8 est n dise ados para su instalaci n en zonas de acceso restringido solamente Una zona de acceso restringido es un lugar al que s lo puede acceder personal de mantenimiento haciendo uso de una herramienta especial una llave y un candado o alg n otro medio de seguridad y que est controlado por la autoridad responsable Brocade VDX 8770 8 Hardware Reference Manual 85 53 1002564 03 B Caution notices CAUTION For the DC input circuit to the system of a Brocade VDX 8770 8 3000W supply make sure there is a 80 amp circuit breaker minimum 48Vdc double pole on the input lugs to the power supply The input wiring for connection to the product should be Listed copper wire 4 AWG marked VW 1 and rated minimum 90o C VORSICHT Bei der Gleichstromeingangsschaltung zum System eines Brocade VDX 8770 8 3000W supply muss sichergestellt werden dass an den Eingangskabelschuhen zur Stromversorgung ein zweipoliger Schalter mit UL Zulassung 80 Ampere und mindestens 48 V Gleichstrom vorhanden ist Die Eingangsleitung zum Anschluss an das Produkt sollte als Kupferdraht 4 AWG angegeben als VW 1 gekennzeichnet und f r mindesten
25. maximum current level 16 0 A max or 48VDC 70 0 A max per power supply Regulatory compliance This section describes the regulatory compliance requirements for the Brocade VDX 8770 8 It contains the following standards e FCC warning US only on page 78 e KCC statement Republic of Korea on page 79 e VCCI statement Japan on page 79 e BSMI statement Taiwan on page 79 e CE statement on page 79 e Canadian requirements on page 80 German statement on page 80 e Laser compliance on page 80 e Safety agency approvals on page 80 e Regulatory compliance standards on page 80 FCC warning US only This equipment has been tested and complies with the limits for a Class A computing device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual might cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at the user s own expense KCC statement Republic of Korea AB 7 71 UPS Y85477 0 71715 eie Svo m Six mister mg E 717101211 ENAH EEN ENE O HE FON
26. minutes The following items are required for the MM replacement e ESD grounding strap e Workstation computer Serial cable e P address of an FTP server for backing up the Brocade VDX 8770 8 configuration e 2 Phillips screwdriver e Replacement management module Faulty management module indicators Confirm that you need to replace the management module The following events might indicate that a management module is faulty e The status LED on the management module is lit steady amber or the power LED is not lit e The management module does not respond to Telnet commands or the serial console is not available e The show mm command does not show that the management module is enabled e Additional information from the show mm command indicates a problem e The clock is inaccurate or the management module does not boot up or shut down normally For more information about error messages refer to the Network OS Message Reference 52 Brocade VDX 8770 8 Hardware Reference Manual 53 1002564 03 Management module removal and replacement 5 Recording critical Brocade VDX 8770 8 information Back up the chassis configuration before you replace a management module Refer to Backing up the configuration on page 31 for backup information Removing a management module For this procedure please refer to ESD precautions and Figure 13 The chassis continues to operate while a management module is being replaced if the redundan
27. the output describes the issue and the affected data and gives you several possible options for action For more detail concerning tese options refer to the Using the Chassis ID CID Recovery Tool chapter in the Brocade Network OS Administrator s Guide and the cidrecov topic in the Network OS Command Reference TABLE 16 Options for the CID Recovery Tool Condition Recovery option One non critical seeprom is Tool displays the CID to be recovered and prompts to continue or corrupted abort Both non critical seeproms are Tool displays both CIDs to be recovered with default data and corrupted prompts to continue or abort Neither non critical seeprom is Tool prompts for the CID to be recovered or to abort corrupted but there is a data mismatch No corruption or mismatch is found Tool displays that there is nothing to be done and then exits on acknowledgement SFP transceiver removal and replacement Use the following procedure to remove and replace an SFP or SFP transceiver DANGER All fiber optic interfaces use Class 1 lasers DANGER Laser radiation Do not view directly with optical instruments Class 1 laser products Time and items required The replacement procedure for one transceiver takes less than five minutes You should have the following items available e Replacement SFP or SFP transceiver e Optical transceiver extraction tool Most Brocade switches and backbones come with a transc
28. 34 35 36 37 38 39 40 41 42 Brocade VDX 8770 8 Hardware Reference Manual 53 1002564 03 69 70 5 Cable routing table TABLE 17 Cable routing table for the Brocade VDX 8770 8 48 ports shown Continued Slot port Cable labels Connected device Slot port of device Slot Port Switch end Device end 43 44 45 46 47 48 Brocade VDX 8770 8 Hardware Reference Manual 53 1002564 03 Appendix Specifications A In this appendix General SHSCIIGAUONGS usua Rees d docens ROS Rp UN ORA RUN ated Al ica a else ei 71 Susrem archlteobUle sso eter cedar esses EE Ee TL e Sole Size dd WES ieee ree 2 S ysLer component WEISS cs celos e a acad eee aa 72 e Ethernet port supported optics 00 0c o Ta PUNEFDDIDUS e onere sour A A BERGE Ede eee NE e 74 EE OLIGO EET A TT A UR REX E ROGA RS GCKR EE TT e Regulatory compliance ici 78 Environmental regulation c mpliaree 00 ee llli nr rnt hmm 81 General specifications The Brocade VDX 8770 8 is compliant with United States and international safety and Electromagnetic Compatibility EMC standards Table 18 lists the general specifications for the Brocade VDX 8770 8 TABLE 18 General specifications Specification Description System architecture Nonblocking shared memory virtual output queued System processor 1 5 GHz Classes of service 8 Port to port latency 3 63 us System architecture T
29. 53 1002564 03 o 23 Brocade VDX 8770 8 Hardware Reference Manual BROCADE Copyright 2012 2013 Brocade Communications Systems Inc All Rights Reserved ADX AnylO Brocade Brocade Assurance the B wing symbol DCX Fabric OS ICX MLX MyBrocade OpenScript VCS VDX and Vyatta are registered trademarks and HyperEdge The Effortless Network and The On Demand Data Center are trademarks of Brocade Communications Systems Inc in the United States and or in other countries Other brands products or service names mentioned may be trademarks of their respective owners Notice This document is for informational purposes only and does not set forth any warranty expressed or implied concerning any equipment equipment feature or service offered or to be offered by Brocade Brocade reserves the right to make changes to this document at any time without notice and assumes no responsibility for its use This informational document describes features that may not be currently available Contact a Brocade sales office for information on feature and product availability Export of technical data contained in this document may require an export license from the United States government The authors and Brocade Communications Systems Inc shall have no liability or responsibility to any person or entity with respect to any loss cost liability or damages arising from the information contained in this book or the computer programs that ac
30. 63A AS 3112 IEC 60309 C20 125V only USA Canada Schuko Australia New 32A 6h 230V 20A 250V USA Canada Mexico other Continental Zealand 12 AWG Mexico other locations Europe connect to locations in cabinet power strip only All locations O E E E Turkey X X United Arab X X Emirate United Kingdom X X United States X X X Venezuela X X X Yugoslavia X X Power cord notice A CAUTION This switch might have more than one power cord To reduce the risk of electric shock disconnect all power cords before servicing Power cord notice Japan Denan HER NOR PALO ER RC BER LZR WT O BJ PILAR IC Bast lL BERI S TA HEUER Out RS SIUCTWSbEOCH D ULCItho XH Live Su KKEOREOMA amp 7R TE EE N ET ATTENTION Never use the power cord packed with your equipment for other products 76 Brocade VDX 8770 8 Hardware Reference Manual 53 1002564 03 Safety notices Safety notices A When using this product observe the danger caution and attention notices in this manual The notices are accompanied by symbols that represent the severity of the safety condition NOTE Translated safety notices are in the Brocade Product Safety Notices publication which is available on http my brocade com The danger and caution notices are listed in numerical order based on their IDs which are displayed in parentheses for example DOO4 at the end of each notice Use this ID to locate the translations of these danger and caution notices in th
31. 8770 8 running Brocade Network OS version 3 0 0 and later What s new in this document The following changes have been made since this document was last released e The NEBS GR 1089 installation requirements were added NEBS requirements on page 77 e The air filter replacement procedure was added Air filter removal and replacement on page 62 Reference to 1Gb transceivers changed to SX short wavelength and LX long wavelength Brocade VDX 8770 8 features on page 1 e The LED aspects for the management module Ethernet port were changed Determining the status of a management module on page 40 Document conventions This section describes text formatting conventions and important notices formats Text formatting The narrative text formatting conventions that are used in this document are as follows bold text Identifies command names Identifies GUI elements Identifies keywords and operands Identifies text to enter at the GUI or CLI italic text Provides emphasis Identifies variables Identifies paths and Internet addresses Identifies document titles code text Identifies CLI output Identifies syntax examples In actual examples command lettercase is often all lowercase Otherwise this manual specifically notes those cases in which a command is case sensitive xiv Brocade VDX 8770 8 Hardware Reference Manual 53 1002564 03 Command syntax conventions Command syntax in this manual follows these conventions comma
32. A WA NEO ROI ASAE E Soe Bech 78 Brocade VDX 8770 8 Hardware Reference Manual 53 1002564 03 Regulatory compliance A Class A device Broadcasting Communication Device for Office Use This device obtained EMC registration for office use Class A and may be used in places other than home Sellers and or users need to take note of this VCCI statement Japan Te V AP PU SL RUE tet UG Pt EI HE m VCCI ORE s c A Tis Ria CT A E EE CHEN AIRE Hd AUD ZR RAS BEIITCBRENSTEMHVET This is a Class A product based on the standard of the Voluntary Control Council for Interference by Information Technology Equipment VCCI If this equipment is used in a domestic environment radio disturbance might arise When such trouble occurs the user might be required to take corrective action BSMI statement Taiwan ZA ARR A ZS Soke ive ANA TEE TERES BE HIIS PYRE ee EA See C EEV P gt AL EE E Warning This is Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures CE statement This is a Class A product In a domestic environment this product might cause radio interference and the user might be required to take corrective measures The standards compliance label on
33. All locations O i i E E Argentina X X Australia X X Austria X X Bahrain X X Belgium X X Brazil X X X Chile X X China People s X X Rep Czech Rep of X X Denmark X X Egypt X X England X X Finland X X France X X Germany X X Greece X X Hong Kong X X Hungary X X 74 Brocade VDX 8770 8 Hardware Reference Manual 53 1002564 03 Power cords A TABLE 23 Power cord types international Continued Country Plug style NEMA 5 20P NEMA L6 20 CEE 7 7 BS 1363A AS 3112 IEC 60309 C20 125V only USA Canada Schuko Australia New 32A 6h 230V 20A 250V USA Canada Mexico other Continental Zealand 12 AWG Mexico other locations Europe connect to locations in cabinet power strip only All locations C969 0 El E Ez India X X Indonesia X X Ireland North X X Ireland South X X Israel X X Italy X X Japan X X X Korea South X X Malaysia Alternate Recommended X Mexico X X X Monaco X X Netherlands X X New Zealand X X Norway X X Poland X X Portugal X X Puerto Rico X X X Russia X X Saudi Arabia X X Scotland X X Singapore X X South Africa X X Spain X X Sweden X X Switzerland X X Taiwan X X X Brocade VDX 8770 8 Hardware Reference Manual 75 53 1002564 03 A Power cords TABLE 23 Power cord types international Continued Country Plug style NEMA 5 20P NEMA L6 20 CEE 7 7 BS 13
34. Brocade VDX 8770 8 features 0 2 0 c ce eee 1 Brocade VDX 8770 8 hardware components 045 2 Port side of the Brocade VDX G C 08 cease 3 Nonport side of the Brocade VDX 8770 8 llus 4 Brocade VDX 8770 8 line cards 2 0 cece 5 High availability zi cR ccs cm acce RR c RR cn 5 Software featUres isses sense swear A a eee eens 5 E I REMIT 5 E ier aa a E E DATE G ET R AE ar ESEE 5 Virtualization 6 ECOE i paese ne a e d 6 Link oggregration ne 6 OOS EE 6 Management 6 LICENSING sie MEET M ER 7 Installation of the Brocade VDX 8770 8 In this chapter 9 NEIEN ye NN EIN SUN ee dae oan eae 9 iti Time and items required 1 0 0 ee eee ee 9 Items included with the Brocade VDX 8770 8 s 10 Preparing for the Brocade VDX 8770 8 installation 12 Power specifications 13 Environmental requirements 15 Chassis slots s ous ea ee cele rele ee ales VRE a ee 16 Unpacking and installing the Brocade VDX 8770 8 16 Port pret da eA Eie Ate et edes Bee Rea 17 Providing power to the Brocade VDX 8770 8 leu 18 Chapter 3 Logging In and Configuring the Brocade VDX 8770 8 In this Chapter ius recom n Roe RU eR Rire 21 Preparing to configure the Brocade VDX 8770 8 21 Establishing a serial connection to the Brocade VDX 8770 8 22 Logging in to the serial console port 24 Changing the RBridge ID 24 Assigning permanent D s
35. CoE over standard LAGs e Soft zoning support Link aggregration e 802 3ad LACP support Virtual Link Aggregation Group VLAG a LAG that spans multiple physical switches QoS e 8024p marking e Scheduling Strict priority SP Shaped Deficit Weighted Round Robin SDWRR e CEE provisioning and classification e Rewrite marking queuing e Congestion control e Multicast rate limit scheduling Port based SPAN e Layer 2 and Layer 3 ACLs ingress and egress e Port based sFLOW Management e Pv4 or IPv6 management Brocade VDX 8770 8 Hardware Reference Manual 53 1002564 03 Software features e CLI management utilities on Network OS v3 0 0 e sFlow e TRILL Operations Administration and Management OAM e Distributed configuration management DCMa Licensing e VCS licensing available multi node license for more than two nodes enables VCS fabric functionality e FCoE licensing enables FCoE feature set e ayer 3 licensing enables IPv4 routing protocols OSPF VRRP VRRP E Brocade VDX 8770 8 Hardware Reference Manual 53 1002564 03 1 1 Software features Brocade VDX 8770 8 Hardware Reference Manual 53 1002564 03 Chapter Installation of the Brocade VDX 8770 8 2 In this chapter Time and ms OU EE 9 items included with the Brocade VDX SITO SB ear err nr RE RES 10 e Preparing for the Brocade VDX 8770 8 installation 12 e Unpacking and installing the Brocade VDX 8770 8
36. HUE CREER cid au eed atin etd arin Re aen x aH Rin S RAM RB cee x CURE 30 Varivirig correct operatio arrancar AAA Al e Backing Ub SEET MER res rud ERE E EG E Rudi 31 Connecting nebwolk GEERT ENNEN NES ESA nace tale coe 32 e Installing transceivers and attaching cables isr eori retire vissrtares 32 e Maias CADIS e assurer i gau AAA ERE EERE E 34 e Creating Brocade inter switch link trunks See ENER SEN n 34 Preparing to configure the Brocade VDX 8770 8 The Brocade VDX 8770 8 must be configured before it is connected to the fabric and all of the configuration commands must be entered through the active MM The Brocade VDX 8770 8 configuration includes the following parameters RBridge ID If you are going to have more than one switch in a fabric IP address and gateway address for the switch IP addresses host names and gateway addresses for one or two MMs as needed Host name You also need to change passwords from their default values and set the time and date either via NTP or manually Brocade VDX 8770 8 Hardware Reference Manual 53 1002564 03 21 3 Establishing a serial connection to the Brocade VDX 8770 8 In order to retain the changes made during configuration you will have to copy the running configuration file to the startup configuration file This will ensure that the switch reboots to your preferred configuration The configuration information is mirrored to the standby MM if you have installed one which all
37. OT BE OFFERED FOR SALE OR LEASE OR SOLD OR LEASED UNTIL AUTHORIZATION 15 PAN S N LID EAN MODULE O 1 2 ERE Ji SOS SS e CHER I OH OHO ORO LEE Or X ORO ROO OG OXORORO OXORO O OHO OOOO OOO ERIE RIO OPO IO OOOO I E ON CHA EO LACH O OY SS RSS OO ORO ORQHOHROR SII EE CHE O CORRA A Ee C 0 2 i EOS HO OO ORO ORO OO OH ORO ERE RRE ORE EERO BORO RO ROR OREO ROBO s a e etel EOS UO HOO HOO OH ORO REE OO OH OO ROO RS rH CH EE CH a 4 Power supply exhaust vent Ground lug Nonport side of the Brocade VDX 8770 8 sample configuration Brocade VDX 8770 8 Hardware Reference Manual 53 1002564 03 Brocade VDX 8770 8 line cards 1 Brocade VDX 8770 8 line cards Table 1 summarizes the line cards that are available for the Brocade VDX 8770 8 TABLE 1 Line cards available for the Brocade VDX 8770 8 Line card Description 12x40 GbE 12 40 Gbps QSFP Ethernet ports 48x10 GbE 48 1 10 Gbps Ethernet ports 48x1 GbE 48 1 Gbps Ethernet ports High availability High availability is currently limited to management module configuration synchronization Failover to the standby module will occur in case of active module failure but the standby module will go through a cold recovery in which all system components are reset This will disrupt traffic on the chassis The reset
38. Te eee AR 5 Brocade VDX 8770 8 features The Brocade VDX 8770 8 is part of the Brocade Next Generation Data Center Networks product line a highly robust class of network switching platforms that combines breakthrough performance scalability and energy efficiency with long term investment These chassis are designed to address the data growth and application demands of evolving enterprise data centers The Brocade VDX 8770 8 features the Brocade CloudPlex architecture a fabric based Ethernet technology that can present virtual desktops over a global network that integrates both static and cloud based resources The Brocade VDX 8770 8 requires Brocade Network Operating System Network OS v3 0 0 or greater For details about Network OS refer to the Brocade Network OS Administrator s Guide A key licensable feature of the Brocade VDX 8770 8 chassis is Brocade ves technology which includes virtual cluster switching a new set of technologies that allows users to create flatter virtualized and highly available data center networks VCS fabrics are scalable permitting users to expand at their own pace and simplified allowing users to manage the fabric as a single entity VCS fabrics are convergence capable supporting technologies such as iSCSI and NAS as well as Fibre Channel over Ethernet FCoE licensable for storage Key features of the Brocade VDX 8770 8 include e Up to 384 10 GbE or 1 GbE external ports or 96 40 GbE external
39. XXXXXXXXXXXXXXXXXXXXXXX Layer 3 license Feature name LAYER 3 XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX VCS Fabric license Feature name VCS FABRIC Each license key is represented by a string of x characters in the example above Keep a copy of each license key for reference You can display the switch license ID which is required for installing a new license Use the command show license id rbridgeld rbridgelD all You can also use just show license id switch show license id Rbridgeld Licenseld 1 10 00 00 05 1B 00 4C 80 Saving your changes Complete the following steps to make your changes persistent This ensures that if you must reboot the switch the preferences you have set will be in force when the switch comes back up 1 2 30 If necessary log on to the switch by Telnet using the admin account In privileged EXEC mode enter the copy running config startup config command switch copy running config startup config This operation will modify your startup configuration Do you want to continue Y N Y When the confirmation question appears answer Y for Yes The current running configuration containing all of your latest changes is saved to the startup configuration The next time the switch reboots all of the changes will remain in force Brocade VDX 8770 8 Hardware Reference Manual 53 1002564 03 Verifying correct operation 3 Verifying correct operation Complete the following steps to veri
40. _Angeles Setting the clock date and time The following procedure sets the local clock date and time An active NTP server if configured automatically updates and overrides the local clock time Time values are limited to between January 1 1970 and January 19 2038 NOTE You should set the clock only if there are no NTP servers configured Time synchronization from NTP servers overrides the local clock 1 If necessary log in to the switch using the default password the default password is password Be sure you are in privileged EXEC mode 2 Enter the clock set year month dayT hours minutes seconds command The following example sets the clock to March 17 2012 15 minutes past noon switch clock set 2012 03 17T12 15 00 Brocade VDX 8770 8 Hardware Reference Manual 29 53 1002564 03 3 Determining installed software licenses If you want to show the clock and time zone settings use the show clock rbridge id rbridge id all command switch show clock rbridge id 1 2012 03 17 12 15 00 America Los_Angeles Determining installed software licenses Certain licenses are factory installed on the Brocade VDX 8770 8 To determine which licenses are enabled use the show license command The format of the command is show license rbridgeld rbridgelD all You can also use just show license switch show license RbridgeId 1 XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX FCoE Base license Feature name FCOE BASE AUXXXXXXXXXXXXXXXX
41. able 19 describes the system architecture of the Brocade VDX 8770 8 TABLE 19 System architecture Feature Description Ethernet Ports Up to 384 ports Control Processor Redundant active standby management modules Brocade VDX 8770 8 Hardware Reference Manual 71 53 1002564 03 A System size and weight TABLE 19 System architecture Continued Feature Description Scalability Full fabric architecture see the Network OS 3 x Release Notes for the most up to date information Brocade ISLs and Interfaces line card ports automatically come up as Fabric inter switch links Fabric Brocade Trunking ISLs in VCS mode If ISL formation fails the interfaces come up as edge ports Trunk groups of up to eight ports are supported on the 48x10G line card only Media types 1 GbE optical 1 Gb copper SFP 10 GbE optical 10 Gb twinax copper 40 GbE optical System size and weight The weight of the Brocade VDX 8770 8 can vary considerably depending on the combination of modules installed Use Table 20 and Table 21 to determine the weight of the Brocade VDX 8770 8 with your combination of modules TABLE 20 System size and weight System Size or weight Width 43 99 cm 17 32 in Height 66 22 cm 26 0 in 14U Depth 66 04 cm 26 in Brocade VDX 8770 8 weight fully configured 165 56 kg 365 Ib 384 port configuration with eight line cards including two management modules six switch fabric modules four fans eight power
42. able order identify each cable by its physical port It is a good practice to keep a table of cable to port mapping Refer to Cable routing table for a blank cable routing table Disconnect all cables and transceivers from the line card Unscrew the two captive screws at the ends of the line card using the Phillips screwdriver Open the ejectors by rotating them toward the center of the line card face Pull the line card out of the chassis using the ejectors If you are replacing the line card with a line card of a different type enter config terminal to enter configuration mode then the no linecard slot number command This removes the line card configuration and its associated interface configuration from the chassis database so a different type of line card can be used in the slot
43. ade trunks see the Brocade Network OS Administrator s Guide 34 Brocade VDX 8770 8 Hardware Reference Manual 53 1002564 03 Chapter Monitoring System Components 4 In this chapter la oos aha aoe Same o doa A ai da ad aar MUR e 35 Determining the status of a line Gard sisse uh eR RR ER 35 Determining the status of a management module is sisissieisnisiss 40 e Determining the status of a switch fabric module s 41 Determining the status of a power supply isse nn nnne 43 Determining the status of d fall EN ae rr Rr RR EE 44 Determining the status ota CID eege NS aere il 46 Monitoring overview The Brocade VDX 8770 8 is engineered for reliability and requires no routine operational steps or maintenance This chapter provides information about determining the status of each component using LEDs and CLI commands Refer to the Brocade Network OS Administrator s Guide for additional information There are two commands that can be especially helpful in monitoring the health of the Brocade VDX 8770 8 These commands are show chassis and the various show environment commands For details about these commands refer to the Network OS Command Reference Determining the status of a line card Use the following procedure to determine the status of a line card 1 Check the LEDs on the module Figure 5 illustrates the 48x10G line card The 48x1G line card looks the same except for the name on the en
44. agement Tray HERR Cable Comb FRR BRA Cables and Power Cords RA Replacement Doors St Battery Vt XR O O O O O Software Documentation CDs O Og CHEERS o f e ATA IA PY AR PEST 11363 20069 E IPR Tit BOR DIF o Indicates that the content of the toxic and hazardous substance in all the homogeneous materials of the part is below the concentration limit requirement as described in SJ T 11363 2006 x O X X X O 0 O0OlOlO Or OO OO Or O O O O Or O O OO O O x O X X X X X X X OI O O OO OF 0 OF OF O OI OO OO OO Oo ojo OI OO OO OF O 000 OI OO OO OF O 000 OOO O O O Oo O OF OF O Xi ERZA EA HR BAD RARO E ROAD A 5 8 RE HESIT 11363 200639 0708 TEE Se X Indicates that the content of the toxic and hazardous substance in at least one homogeneous material of the part exceeds the concentration limit requirement as described in SJ T 11363 2006 Brocade VDX 8770 8 Hardware Reference Manual 83 53 1002564 03 84 A Environmental regulation compliance Brocade VDX 8770 8 Hardware Reference Manual 53 1002564 03 Appendix Caution and Danger Notices B In this appendix eX SORS NR IS os UL EE det neu M sc es s E Rd CR Ee 85 Danger DEE rada REIR 87 Caution notices The cautions and dangers that appear in this manual are listed below in English German French and Spanish A caution calls your atten
45. al 25 53 1002564 03 3 Logging off the serial console port and disconnecting the serial cable switch config Management 1 1 45 no ip address dhcp switch config Management 1 1 ip address 10 24 85 81 20 switch config Management 1 1 ip gateway address 10 24 80 1 ATTENTION The ip gateway address command will not be available on the Brocade VDX 8770 8 if the L3 or Advanced license is installed In that case use the following command sequence switch config rbridge id 1 switch config rbridge id 1 ip route 0 0 0 0 0 lt default gateway gt If you are going to use an IPv6 address enter the network information in semicolon separated notation as prompted after the ipv6 address operand You should also disable DHCP switch config interface Management 1 1 switch config Management 1 1 no ip address dhcp switch config Management 1 1 ipv6 address f d00 60 69bc 832 e61f 13ff fe67 4b94 64 6 To display the configuration use the show running config interface Management command switch show running config interface Management 1 1 interface Management 1 1 no ip address dhcp ip address 10 24 85 81 20 ip gateway address 10 24 80 1 ipv6 address fd00 60 69bc 832 e61f 13ff fe67 4b94 64 no ipv6 address autoconfig Logging off the serial console port and disconnecting the serial cable You can use the serial port to monitor error messages through the serial connection If the serial port is no longer required use the logout comman
46. an consist of up to 8 ports The octet groups are ports 1 8 9 16 17 24 25 32 33 40 and 41 48 1 NO oO 50 Add the transceivers and cables to the line card ports Position one of the optical transceivers so that the key is oriented correctly to the port Insert the transceiver into the port until it is firmly seated and the latching mechanism clicks Transceivers are keyed so that they can only be inserted with the correct orientation If a transceiver does not slide in easily ensure that it is correctly oriented Position a cable so that the key the ridge on one side of the cable connector is aligned with the slot in the transceiver Insert the cable into the transceiver until the latching mechanism clicks Cables are keyed so that they can be inserted in only one way If a cable does not slide in easily ensure that it is correctly oriented Repeat step 1 and step 2 for the remaining ports If you are using direct attach cables you can insert them at this time Organize the cables Refer to Managing cables Verify the Brocade VDX 8770 8 and port status using the show interface command Verify fabric connectivity using the show fabric all command Installing QSFP transceivers and cables Complete the following steps to install the QSFP transceivers and cables in the 12x40G line cards Because each QSFP transceiver consists of four 10 GbE ports be aware that any problems with one port could affect all four ports in th
47. and items required The replacement procedure for each line card takes less than 10 minutes Removing and restoring transceivers and cables may take longer depending on how many must be changed The following items are required for the line card replacement Electrostatic discharge ESD grounding strap e Workstation computer e Replacement line card or filler panel e 2 Phillips screwdriver e Small form factor pluggable SFP or SFP or QSFP transceivers as needed e Optical and copper cables as needed NOTE For information about the transceivers that are qualified for the Brocade chassis refer to http www brocade com downloads documents matrices Brocade_Compatibility_Matrix pdf Removing a line card For this procedure refer to Figure 12 Complete the following steps to remove a line card ATTENTION If multiple modules are being replaced complete the replacement for one module at a time ATTENTION Follow ESD precautions while removing any line card 1 Check for adequate cable slack Ensure there is plenty of cable slack to remove a line card without cable obstruction 2 Ensure that the part number on the line card being replaced matches the replacement part number 3 Power down the existing line card using the power off linecard slot number command Brocade VDX 8770 8 Hardware Reference Manual 53 1002564 03 Line card removal and replacement 5 NOTE Before removing any cables from a line card note the c
48. and replacement n nnn annann nnnn 67 Removing a QSFP transceiver 2 0 2 00s 67 Replacing a QSFP transceiver 00 c eee eee 68 Cable routing table wis eevee e AE EN E VISITE NN SINN es 68 Appendix A Specifications lrithis appendiss ses edie eee de REGE EE XR PEERS Peewee 71 General specifications 71 System architecture 71 System size and weight 72 System component weights 0000 cece eee eee eee 72 Ethernet port Supported optics 0 00 c eee eee eee 73 Power COrds ssec mee gee ER ea ee 74 Power cord notice ee 76 Power cord notice Japan Denan llle 76 Safety NOUCES os space Ren Ree ee Waa e ta SR as Rive e ere 77 NEBS requirements 77 Brocade VDX 8770 8 Hardware Reference Manual 53 1002564 03 Appendix B Index Brocade VDX 8770 8 Hardware Reference Manual 53 1002564 03 Regulatory compliance llle 78 FCC warning US oni 78 KCC statement Republic of Korea lees 79 VCCI statement Japan 0 2 ce eee 79 BSMI statement Taiwan 00 cee eee eee eee 79 CEStatement ic vba re eA eee dci haa a 79 Canadian requirements 80 German Statement 80 Laser compliance sexe kx ERR e eee eee eee EN 80 Safety agency approvals 0c eee eee eee 80 Regulatory compliance standards lusus 80 Environmental regulation compliance llle 81 China ROHS i3 i i eer in 81 Caution and Dange
49. as utilizadas en este manual Brocade VDX 8770 8 Hardware Reference Manual 87 53 1002564 03 88 B Danger notices DANGER Laser Radiation Do Not View Directly with Optical Instruments Class 1M Laser Products GEFAHR Laserstrahlung Schauen Sie nicht direkt mit optischen Instrumenten in den Laserstrahl herein Klasse 1M Laserprodukte DANGER Rayonnement de laser Ne regardez pas directement avec les instruments optiques Produits de laser de la classe 1M PELIGRO Radiacion de Laser No vea directamente con Instrumentos Opticos Clase 1M de Productos de Laser DANGER GEFAHR All fiber optic interfaces use Class 1 lasers Alle Glasfaser Schnittstellen verwenden Laser der Klasse 1 DANGER Toutes les interfaces en fibres optiques utilisent des lasers de classe 1 PELIGRO Todas las interfaces de fibra ptica utilizan l ser de clase 1 DANGER Installation and removal of the unit must be carried out by qualified personnel only GEFAHR Die Installation und Entfernung der Einheit d rfen nur von qualifiziertem Personal ausgef hrt werden DANGER L installation et la d pose de l unit doivent tre confi es uniquement du personnel qualifi PELIGRO La instalaci n y desinstalaci n de la unidad debe llevarse a cabo solamente por personal cualificado DANGER Disconnect the power cord from all power sources to completely remove power from the devi
50. at 70 C 104 F with maximum gradient of 10 158 F per hour Altitude O to 3 km 10 000 ft above sea level O to 12 km 40 000 ft above sea level Shock 20G 6 ms duration half sine wave 33G 11 ms duration half sine wave Vibration 0 5G p p 5 500 Hz at 1 0 octave minute 2 0G p p 5 500 Hz at 1 0 octave minute Airflow Maximum 1250 cu ft min 2124 cu None required m hr Nominal 325 cu ft min 552 cu m hr Maximum heat Up to 11500W or 39 250 BTU hr Not applicable dissipation NOTE The 0 to 40 C 32 to 104 F range applies to the ambient air temperature at the air intake vents on the port side of the Brocade VDX 8770 8 The temperature inside the Brocade VDX 8770 8 can be up to 90 C 194 F for some modules during operation Brocade recommends that the internal tempertaure not exceed 75 C 167 F Cooling policy is based on a combination of ambient temperature and measured temperature on the modules Various combinations will result in an increase in fan speed to create more cooling in the Switch If a component approaches a critical temperature that will trigger a module shutdown there will be a WARNING message in the raslog followed by a CRITICAL message saying that the module will shut down in two minutes Use the show environment command to view temperature status Brocade VDX 8770 8 Hardware Reference Manual 15 53 1002564 03 2 Unpacking and installing the Brocade VDX 8770 8 Chassis slots Switch slots are co
51. ccount name and the password parameter 3 When prompted enter the new password and press Enter Switch configure terminal Entering configuration mode terminal switch config username admin password new password lt WORD gt User password satisfying password attributes Configuring the IP addresses You can configure the Product Name with a static IP address DHCP is not supported on the Product Name The Product Name supports both IPv4 and IPv6 format addresses Setting a static IP address Complete the following steps to set a static IP address 1 Login to the MM using the default password the default password is password 2 Enter configuration mode using the configure terminal command 3 Specify the chassis with the rbridge id command switch config rbridge id 1 4 Usethe chassis virtual ip command to set the IP address for the chassis switch config rbridge id 1 chassis virtual ip 10 20 236 132 20 5 Use the ip address command to set the Ethernet IP address for the MMs If you are going to use an IPv4 IP address enter the IP address in dotted decimal notation You should also disable DHCP and enter a gateway address as well When you have assigned the IP and gateway addresses to management interface 1 1 you should also assgin IP and gateway addresses to management interface 1 2 if you have installed a second MM switch config interface Management 1 1 Brocade VDX 8770 8 Hardware Reference Manu
52. ce GEFAHR DANGER Ziehen Sie das Stromkabel aus allen Stromquellen um sicherzustellen dass dem Gerat kein Strom zugef hrt wird D branchez le cordon d alimentation de toutes les sources d alimentation pour couper compl tement l alimentation du dispositif PELIGRO Para desconectar completamente la corriente del instrumento desconecte el cord n de corriente de todas las fuentes de corriente Brocade VDX 8770 8 Hardware Reference Manual 53 1002564 03 Danger notices B DANGER If the installation requires a different power cord than the one supplied with the device make sure you use a power cord displaying the mark of the safety agency that defines the regulations for power cords in your country The mark is your assurance that the power cord can be used safely with the device GEFAHR Falls f r die Installation ein anderes Stromkabel erforderlich ist wenn das mit dem Gerat gelieferte Kabel nicht passt m ssen Sie sicherstellen dass Sie ein Stromkabel mit dem Siegel einer Sicherheitsbeh rde verwenden die f r die Zertifizierung von Stromkabeln in Ihrem Land zust ndig ist Das Siegel ist Ihre Garantie dass das Stromkabel sicher mit Ihrem Ger t verwendet werden kann DANGER Si l installation n cessite un cordon d alimentation autre que celui fourni avec le dispositif assurez vous d utiliser un cordon d alimentation portant la marque de l organisation responsable de la s curit qui d
53. company it The product described by this document may contain open source software covered by the GNU General Public License or other open source license agreements To find out which open source software is included in Brocade products view the licensing terms applicable to the open source software and obtain a copy of the programming source code please visit http www brocade com support oscd Brocade Communications Systems Incorporated Corporate and Latin American Headquarters Asia Pacific Headquarters Brocade Communications Systems Inc Brocade Communications Systems China HK Ltd 130 Holger Way No 1 Guanghua Road San Jose CA 95134 Chao Yang District Tel 1 408 333 8000 Units 2718 and 2818 Fax 1 408 333 8101 Beijing 100020 China E mail info brocade com Tel 8610 6588 8888 Fax 8610 6588 9999 E mail china info brocade com European Headquarters Asia Pacific Headquarters Brocade Communications Switzerland S rl Brocade Communications Systems Co Ltd Shenzhen WFOE Centre Swissair Citic Plaza Tour B 4 me tage No 233 Tian He Road North 29 Route de l A roport Unit 1308 13th Floor Case Postale 105 Guangzhou China CH 1215 Gen ve 15 Tel 8620 3891 2000 Switzerland Fax 8620 3891 2111 Tel 41 22 799 5640 E mail china info brocade com Fax 41 22 799 5641 E mail emea infoGbrocade com Document History Title Publication number Summary of changes Date Brocade VDX 8770 8 Hardwar
54. d e Figure 6 illustrates the 12x40G line card The LED patterns may temporarily change during POST and other diagnostic tests For information about how to interpret the LED patterns refer to Table 9 2 Youcan use the show linecard or show slots command to see if your line cards are enabled The line cards are labeled L1 through L8 in the output The show linecard command limits the output to the line card slots only 3 Tocheckthe status of the interfaces ports on the line card use the show interface command Brocade VDX 8770 8 Hardware Reference Manual 35 53 1002564 03 36 4 Determining the status of a line card Line card illustrations 48 X DE RSS ADO 382 OTE w ra S gt Bc Br lt Es gt G DIS gt 3 Es gt gt lt Es gt gt lt lt a ma Lra gt gt 050 E r Lr gt gt e my Iu 1 Status LED 3 PortStatu
55. d to log out of the serial console remove the serial cable and replace the protective plug in the serial port Establishing an Ethernet connection to the Brocade VDX 8770 8 After using a serial connection to configure the IP addresses for the Brocade VDX 8770 8 you can connect the active MM to the local area network LAN NOTE Connecting the MMs to a private network is recommended By establishing an Ethernet connection you can complete the Brocade VDX 8770 8 configuration using a serial session Telnet or management application such as Brocade Network Advisor NOTE To protect the Ethernet port from damage keep the cover on the port when not in use Perform the following steps to establish an Ethernet connection to the Brocade VDX 8770 8 1 Remove the shipping plug from the Ethernet port on the active MM 2 Insert one end of an Ethernet cable into the Ethernet port 26 Brocade VDX 8770 8 Hardware Reference Manual 53 1002564 03 Customizing a host name 3 3 Connectthe other end to an Ethernet 10 100 1000 BaseT LAN The Brocade VDX 8770 8 can be accessed through a remote connection using the command line by way of Telnet or any of the management tools such as Brocade Network Advisor 4 To complete any additional Brocade VDX 8770 8 configuration procedures through a Telnet session log in to the Brocade VDX 8770 8 by Telnet using the admin login The default password is password Customizing a host name This procedur
56. ded and numbered to differentiate between management module slots switch fabric module slots and line card slots Management modules MM must be installed only in slots M1 and M2 Switch fabric modules SFM must be installed only in slots S1 through S6 There must be at least one SFM installed in either slot S3 or slot S4 The line card slots L1 through L8 can be filled with either 48x1G 48x10G or 12x40G line cards Unused slots must be filled with the correct filler panels to maintain adequate cooling Unpacking and installing the Brocade VDX 8770 8 16 Use the following procedure to unpack and install your Brocade VDX 8770 8 uN CAUTION Use safe lifting practices when moving the product CO15 NOTE A fully populated Brocade VDX 8770 8 weighs approximately 165 56 kg 365 Ib and requires a hydraulic or assisted lift to install it 1 Unpack the Brocade VDX 8770 8 a Cut the bands that encircle the packaging b Slide the upper portion of the cardboard shipping box up off the pallet and shipping tray NOTE The Brocade VDX 8770 8 packaging incorporates a wood pallet and brackets The switch sits on top of a corrugated cardboard shipping tray c Save the packing materials for use when returning a switch d Leave the switch on top of the shipping tray and pallet if the switch must be transported to the installation location Use a pallet jack or other assisted lift to transport the new switch to the installation area
57. ditions specified in the procedures are followed The following sections contain FRU removal and replacement procedures A DANGER The procedures in this manual are for qualified service personnel ESD precautions The Brocade VDX 8770 8 contains ESD sensitive FRUs When working with any Brocade VDX 8770 8 FRU use correct electrostatic discharge ESD procedures Brocade VDX 8770 8 Hardware Reference Manual 47 53 1002564 03 5 Cable management comb removal and replacement e Wear a wrist grounding strap connected to chassis ground if the Brocade VDX 8770 8 is plugged in or a bench ground Refer to Port side of the Brocade VDX 8770 8 on page 3 for the location of the ESD jack e Store ESD sensitive components in antistatic packaging Cable management comb removal and replacement 48 The Brocade VDX 8770 8 can continue to operate during the replacement of the cable management comb Time and items required The replacement procedure for the cable management comb takes less than five minutes A 1 Phillips screwdriver is required See Figure 11 Removing a cable management comb Complete the following steps to remove the cable management comb 1 Remove the cables from the cable management comb and rearrange the cables around the comb 2 Unscrew and save the four 4 screws holding the comb to the chassis Retain the screws Support the comb to prevent it from falling 3 Remove the comb Brocade VDX 8770
58. e B8770 prime Record the new name for reference 3 To verify the new chassis name you can run the show running config switch attributes rbridge id command switch show running config switch attributes 1 Brocade VDX 8770 8 Hardware Reference Manual 27 53 1002564 03 3 Setting the date and time Setting the date and time 28 The MM maintains the current date and time inside a battery backed real time clock RTC circuit Date and time are used for logging events Switch operation does not depend on the date and time a Product Name with an incorrect date and time value functions properly Because the date and time are used for logging error detection and troubleshooting you should set them correctly Time zones You can set the time zone for a switch by using the clock TimeZone command The time zone setting has the following characteristics The time zone setting automatically adjusts for Daylight Savings Time e Changing the time zone on a switch updates the local time zone setup and is reflected in local time calculations e By default all switches are in the Greenwich Mean Time GMT time zone 0 0 If all switches in a fabric are in one time zone it is possible for you to keep the time zone setup at the default setting e System services that have already started will reflect the time zone changes only after the next reboot e Time zone settings persist across failover for high availability Time zone set
59. e Brocade Product Safety Notices NEBS requirements Table 24 lists the installation requirements for meeting the NEBS GR 1089 compliance TABLE 24 Reference Intrabuilding or Intra connection NEBS installation requirements for the Brocade VDX 8770 8 Warning requirement or statement WARNING The intra building copper Ethernet ports of the equipment or subassembly are suitable for connection to intrabuilding or unexposed wiring or cabling only The intra building port s of the equipment or subassembly MUST NOT be metallically connected to interfaces that connect to the outside plant OSP or its wiring These interfaces are designed for use as intra building interfaces only Type 2 or Type 4 ports as described in GR 1089 CORE Issue 6 and require isolation from the exposed OSP cabling The addition of Primary Protectors is not sufficient protection in order to connect these interfaces metallically to OSP wiring First Level Lightning Criteria AC Power Ports WARNING The Brocade VDX 8770 8 shall be connected to and external Special Protection Devices SPD when installed and connected to commercial AC power Class A2 Voltage Accessibility The Brocade VDX 8770 8 shall be located in a restricted access location were only crafts personnel are allowed access Class B Voltage Accessibility The Brocade VDX 8770 8 shall be located in a restricted access location were only crafts personnel are allowed access Equipmen
60. e Reference 53 1002564 01 New document Sept 2012 Manual Brocade VDX 8770 8 Hardware Reference 53 1002564 02 NEBS GR 1089 installation Mar 2013 Manual requirements were added including air filter Brocade VDX 8770 8 Hardware Reference 53 1002564 03 Additional NEBS requirement Aug 2013 Manual added for air filter replacement Changed referenec to availablility of SX and LX transceivers Changed LED indication for Ethernet management link on MM Brocade VDX 8770 8 Hardware Reference Manual 53 1002564 03 Brocade VDX 8770 8 Hardware Reference Manual 53 1002564 03 Contents About This Document Chapter 1 Chapter 2 Brocade VDX 8770 8 Hardware Reference Manual 53 1002564 03 In this Chapter css ers pe cem xp eA r3 xc xiii How this document is organized 0 00 cece eee esses xiii Supported hardware and software Xiv What s new in this document xiv Document conventions 00 ccc eee eee nnn xiv Text TOMATE sss sina sios io sonas ca a S iacaa iE xiv Command syntax conventions XV Command examples 0000 eee ee eee XV Notes cautions and warnings 0 cece e eee eee XV Notice to the reader cc eee eee xvi Additional information llle xvi Brocade r SOUICES 1 eene xvi Other industry resources 2 ke eee xvi Getting technical help iesu eevee Rr RR EE Rh ea xvii Document feedback xvii Brocade VDX 8770 8 Overview rb Ee E e EE 1
61. e is optional While still in Telnet you can change the host switch name of the switch The host name of the Brocade VDX 8770 8 can be up to 30 characters long using Network OS release 3 0 0 or later can include letters numbers hyphens and underscore characters and must begin with a letter The default host name is sw0 The host name is displayed at the system prompt 1 Enter switch attributes followed by the Rbridge ID and the host name operand with the new name If you have changed the Rbridge ID be sure to use that ID switch config switch attributes 1 host name rack1 8770 8 Record the new name for reference To verify the new host name you can run the show running config command in EXEC mode switch show running config Customizing a chassis name This procedure is optional While still in Telnet you can change the chassis name of the switch The chassis name of the Brocade VDX 8770 8 can be up to 30 characters long can include letters numbers hyphens and underscore characters and must begin with a letter The default chassis name is VDX8770 8 Brocade recommends that you customize the chassis name for each platform because some of the system logs refer to the platorm by its chassis name 1 Enter switch attributes followed by the Rbridge ID and the chassis name operand with the new chassis name If you have changed the rbridge ID be sure to use that ID switch config switch attributes 1 chassis nam
62. e is required NOTE The 802 3ab standard automatic MDI or MDIX detection calls for automatic negotiation of the connection between two 1000Base T ports Therefore a crossover cable may not be required a straight through cable may work as well Connecting to workstations servers or routers Straight through unshielded twisted pair UTP cabling is required for direct UTP attachment to workstations servers or routers using network interface cards NICs Fiber cabling is required for direct attachment to Gigabit NICs or switches and routers through fiber ports Connecting a network device to a fiber port For direct attachment from the Brocade device to a Gigabit NIC switch or router fiber cabling with an LC connector is required Testing connectivity After you install the network cables you can test network connectivity to other devices by observing the LEDs related to network connection and performing trace routes Installing transceivers and attaching cables The following two sets of steps cover the installation of transceivers and cables for most SFPs and for QSFPs 32 Brocade VDX 8770 8 Hardware Reference Manual 53 1002564 03 Installing transceivers and attaching cables 3 Installing SFP and SFP transceivers and cables Complete the following steps to install SFP and SFP transceivers If you are implementing Brocade trunks be aware that trunking is supported only on the 48x10GbE line card The port groups c
63. e quad 1 Position one of the QSFP transceivers so that the key is oriented correctly to the port 2 Usingthe tab insert the transceiver into the port until it is firmly seated You can feel a small click when it completely seats Transceivers are keyed so that they can only be inserted with the correct orientation If a transceiver does not slide in easily ensure that it is correctly oriented When the transceiver is correctly seated the status LED will turn solid amber 3 Remove the protective plug from the QSFP transceiver and the protective cap from the special QSFP cable and insert it into the transceiver until it is firmly seated The cables are also keyed to fit into the transceivers correctly When the cable is correctly seated the status LED will change from amber to green 4 Repeatstep 1 through step 3 for the remaining QSFP ports Organize the cables Refer to Managing cables Brocade VDX 8770 8 Hardware Reference Manual 33 53 1002564 03 Managing cables 3 Managing cables Cables can be organized and managed in a variety of ways for example using cable channels on the port sides of the rack or patch panels to minimize cable management On the Brocade VDX 8770 8 the cable management comb is located above the modules on the port side Following is a list of recommendations Leave at least 1 m 3 28 ft of slack for each port cable This provides room to remove and replace the Brocade VDX 8770 8 allows for inadvert
64. e to remove and replace a fan ATTENTION The Brocade VDX 8770 8 can continue operating during the fan replacement Time and items required The replacement procedure for each fan takes less than 5 minutes The following items are required for the fan replacement e Replacement fan e 2 Phillips screwdriver Removing a fan For the following procedure refer to Figure 17 Complete the following steps to remove a fan from the chassis 1 Before removing a fan verify that the other fans are functioning properly The power LEDs should be steady green A DANGER Be careful not to insert your fingers into the fan while removing it from the device The fan may still be spinning at high speed 2 Use the screwdriver to loosen the four captive screws at the top and bottom of the fan 3 Grasp the handle and pull sliding the fan from the chassis and supporting the fan from beneath as you remove it 60 Brocade VDX 8770 8 Hardware Reference Manual 53 1002564 03 Fan removal and replacement FIGURE 17 Removal and replacement of the fan Replacing a fan assembly For the following procedure refer to Figure 17 Complete the following steps to replace the fan in a chassis 1 Orient the fan and slide it into the chassis pushing firmly to ensure that it is seated 2 Verify that the power LED displays a green light 3 Usethe screwdriver to tighten the
65. eiver extraction tool Figure 19 and holster The extraction tool is designed to remove transceivers from modules where the space is limited Brocade VDX 8770 8 Hardware Reference Manual 65 53 1002564 03 5 66 SFP transceiver removal and replacement C a FIGURE 19 Optical transceiver extraction tool Removing a transceiver For the following procedure refer to Figure 20 Complete the following steps to remove an SFP or SFP transceiver 1 Remove any cables that are inserted into the transceiver Use the extraction tool to open the cable latching mechanism 2 Using the hooked end of the tool pull the bail wire handle away from its pivot point and out sliding the transceiver out of the switch or module 1 SFP or SFP bail FIGURE20 Optical transceiver with bail open Brocade VDX 8770 8 Hardware Reference Manual 53 1002564 03 QSFP transceiver removal and replacement 5 Replacing a transceiver For the following procedure refer to Figure 20 Complete the following steps to replace an SFP or SFP transceiver 1 Making sure that the bail wire handle is in the unlocked or open position position the optical transceiver so that the key is oriented correctly to the port Insert the transceiver into the port until it is firmly seated and the latching mechanism clicks Transceivers are keyed so that they can only be inserted with the correct orientation If a transceiver does not slide in easily
66. ensure that it is correctly oriented 2 Position a cable so that the key the ridge on one side of the cable connector is aligned with the slot in the transceiver Insert the cable into the transceiver until the latching mechanism clicks Cables are keyed so that they can be inserted in only one way If a cable does not slide in easily ensure that it is correctly oriented QSFP transceiver removal and replacement Use this procedure to remove and replace a QSFP transceiver Because each QSFP consists of four 10 GbE ports be aware that any problems with one port could affect all four ports in the quad A DANGER All fiber optic interfaces use Class 1 lasers A DANGER Laser radiation Do not view directly with optical instruments Class 1 laser products Removing a QSFP transceiver Complete the following steps to remove a QSFP transceiver 1 Remove the cable from the transceiver 2 Usingthe integrated tab remove the QSFP transceiver from the port 3 Insert a protective plug into the transceiver and put it aside Brocade VDX 8770 8 Hardware Reference Manual 67 53 1002564 03 5 Cable routing table FIGURE21 QSFP cable and transceiver with bail open Replacing a QSFP transceiver Complete the following steps to replace a QSFP transceiver 1 Position the new QSFP transceiver so that the key is oriented correctly to the port 2 Using the integrated tab insert the transceiver into the port until it is firmly
67. ent movement of the rack and helps prevent the cables from being bent to less than the minimum bend radius The minimum bend radius should be no smaller than ten times the cable radius The minimum radius to which a 50 micron cable can be bent under full tensile load is 5 1 cm 2 in For a cable under no tensile load that minimum is 3 0 cm 1 2 in If ISL trunking is in use group the cables by trunking group Generally Velcro9 type cable restraints are recommended to avoid creating sharp bends or kinks in the cables Do not use tie wraps with optical cables because they are easily overtightened and can damage the optic fibers For easier maintenance label the fiber optic cables and record the devices to which they are connected Do not route cables in front of the air intake vents Route the cables to the top of the Brocade VDX 8770 8 through the cable comb Keep LEDs visible by routing port cables and other cables away from the LEDs Creating Brocade inter switch link trunks In VCS mode unless specifically disabled Brocade trunking between adjacent switches is automatic in order to form the VCS cluster This occurs only on the 48x10G line cards All ports must be in the same port group and must be configured at the same speed There is a limit of eight ports per trunk group While a VCS license is required when connecting more than two switches no separate licensing is required for Brocade trunking For more information about Broc
68. er to Environmental requirements to plan for your environmental needs Refer to Managing cables to plan for cable management A DANGER The procedures in this manual are for qualified service personnel The following steps are required to ensure correct installation and operation 1 Provide a space that is 15 rack units 15U high 61 29 cm 24 09 in deep and 43 74 cm 17 22 in wide One rack unit is equal to 4 45 cm 1 75 in Plan to install the Brocade VDX 8770 8 with the port side facing the air intake aisle Airflow is from the port side of the switch to the fan side Ensure that the rack is balanced and mechanically secured to provide stability in the event of an earthquake and that the equipment does not exceed the rack s weight limits NOTE Doorways must be wider than 91 cm 36 in to accommodate the switch 2 Ensure that dedicated electrical branch circuits with the following characteristics are available e Upto eight dedicated fused 200 240 VAC 50 60 Hz feeds or 48 VDC one per power supply e One cable for each power supply A CAUTION Use a separate branch circuit for each AC power cord for redundancy in case one of the circuits fails Protected by a circuit breaker in accordance with local electrical codes e Supply circuit line fusing and wire size adequate to the electrical rating on the switch nameplate Location close to the switch and easily accessible 12 Brocade VDX 8770
69. erence Manual 81 53 1002564 03 82 A Environmental regulation compliance ABRA EPUP RE EPUP a AUUEP mA eu Moker mP It Brocade PAE AIG i IER RK RARER Brocade KRZA MARES EPI EAT HAAR OE Pe CD LESH a unt Sak Hlp A PEAS BOE aN RE Br ocade AIL IR AEH A Aa NE ERIE FHSS ES EE CU EA IAS i Ti o EPUP BRE PERE FAL PERI onse MANE Er ho Brocade VDX 8770 8 Hardware Reference Manual 53 1002564 03 Environmental regulation compliance A China RoHS hazardous substances toxic substances HS TS concentration chart In accordance with China s Management Measures on the Control of Pollution caused by Electronic Information products Decree No 39 by the Ministry of Information Industry the following information is provided regarding the names and concentration level of hazardous substances HS which may be contained in this product UE IE L AKG NA Toxic Hazardous Substances and Elements Table UE ILE L ES RO Ph x Hg 4 Ca WN Pt HH BRR A Cr VD PBB O WAY aw cc Sat OI O O o O Oe V amp x O O EE ng Fan Blower Assemblies RAR SB HE PCBA Cards ALBA EM HBA Host Bus Adapter HBA USB DS USB Flash Drive Ch Power Supply Kit ER SFP Optics Rat Sheet Metal DIESES Chassis Assembly VU Se SR NOB A Mechanical Brackets amp Slides TR TRIS 70 Slot Filler BARER Cable Man
70. es 33 Managing cables 0 cece cette eee 34 Creating Brocade inter switch link trunkS na sana ssnaanannuaa 34 Monitoring System Components In this Chapter eg ere een poete e ect docte Wiens ette tds 35 Monitoring overview oococococcoc III 35 Determining the status of a line car 35 Line card illustrations 36 Determining the status of a management module 40 Determining the status of a switch fabric module 41 Determining the status of a power supply ooocoocooooo 43 Determining the status of afan llli lle lesen 44 Determining the status of a CID card lslsllussn 46 Removal and Replacement Procedures IM this Chapter ege an xe E e x ex Y 47 IntroductlOm s ute Aci 47 ESD precautions vesc eri me cR en RA Bera E 4T Cable management comb removal and replacement 48 Time and items required 2 0 cc ee 48 Removing a cable management comb s a sssusurrurerana 48 Replacing a cable management comb o 49 Line card removal and replacement 000 eee eens 49 Time and items required 2 0 cee eee 50 Removing a line cand eee 50 Replacing a line cord 51 Management module removal and replacement 52 Time and items required llli leere 52 Faulty management module indicators 52 Recording critical Brocade VDX 8770 8 information 53 Removing a management module
71. eworde ee eee eee eee 24 Changing the default account passwords 25 Configuring the IP addresees 0 0 00 c cece eee eee 25 Setting a static IP address 0 0 c eee eee 25 Logging off the serial console port and disconnecting the serial Cable ui EVE eed CEA coed Anh RUE SER ae 26 Establishing an Ethernet connection to the Brocade VDX 8770 8 0 ccc cc eee eee 26 Customizing a host name 27 Customizing a chassis name 27 Setting the date and me 28 TIMEZONES iste estet stead peti ected Rok Rvp ted fopra Sank 28 Time synchronization 0 000 cece eee 28 Synchronizing local time using NTP 020 000ee 28 Setting the time zone 29 Setting the clock date and me 29 Determining installed software licenses sssan ena nnun nna 30 Saving vour changes lees 30 Verifying correct operation llle 31 Backing up the configuration llle 31 Connecting network devices 0 00 eee 32 Connecting to Ethernet devices 32 Connecting to workstations servers or routers 32 Connecting a network device to a fiber port 32 Testing Connect 32 Brocade VDX 8770 8 Hardware Reference Manual 53 1002564 03 Chapter 4 Chapter 5 Brocade VDX 8770 8 Hardware Reference Manual 53 1002564 03 Installing transceivers and attaching cables 32 Installing SFP and SFP transceivers and cables 33 Installing QSFP transceivers and cabl
72. extremely hazardous to you Safety labels are also attached directly to products to warn of these conditions or situations Brocade VDX 8770 8 Hardware Reference Manual XV 53 1002564 03 Notice to the reader This document may contain references to the trademarks of the following corporations These trademarks are the properties of their respective companies and corporations These references are made for informational purposes only Corporation Referenced Trademarks and Products Microsoft Corporation Windows Windows NT Internet Explorer Sun Microsystems Inc Sun Solaris Netscape Communications Corporation Netscape Red Hat Inc Red Hat Red Hat Network Maximum RPM Linux Undercover Velcro Industries B V Velcro Additional information xvi This section lists additional Brocade and industry specific documentation that you might find helpful Brocade resources To get up to the minute information go to http my brocade com to register at no cost for a user ID and password White papers online demonstrations and data sheets are available through the Brocade website at http www brocade com products solutions products index page For additional Brocade documentation visit the Brocade website http www brocade com Release notes are available on the MyBrocade website and are also bundled with the Network OS firmware Other industry resources For additional resource information visit
73. four captive screws Brocade VDX 8770 8 Hardware Reference Manual 53 1002564 03 5 61 5 Air filter removal and replacement Air filter removal and replacement 62 You can remove and replace an air filter when it gets too clogged with dirt and dust to operate efficiently You should perform regular physical inspections to determine how often to replace the filter Maintaining clean air filters ensures optimal airflow through the devices Based on the traffic and particulate levels of the installation location the site operator should determine the appropriate replacement intervals are for the filter If the filter were to become sufficiently blocked the thermal policy of the device would notify the administrator of an environmental issue with the system If a site specific interval cannot be determined by the site operator the filter should be replaced on an interval of every 3 months The filters are single use non recyclable They have a UL fire rating of FLAME RETARDANT UL 94HF 1 UAF and PPI measurement of 25 Use this illustration as a reference The chassis is shown in a two post mid mount rack configuration but the mounting of the air filter is the same for any rack mount e e e e dE Beooooooooeooooooo68 FIGURE 18 Removal and replacement of the air filter Brocade VDX 8770 8 Hardware Reference Manual 53 1002564 03 Module fil
74. fy correct operation for the Brocade VDX 8770 8 1 2 3 Check the LEDs to verify that all components are functional If necessary log in to the switch by Telnet using the admin account Enter the show chassis command to verify that the Brocade VDX 8770 8 and its components are operating correctly Enter the show interface command to show the status of all of the ports in the line cards Enter the show fabric all command to verify the operation of the Brocade VDX 8770 8 in the fabric Backing up the configuration Complete the following steps to back up the configuration for the Brocade VDX 8770 8 If you back up your configuration to a USB device be sure to use a Brocade branded USB device The Brocade USB device comes pre configured with four directories firmware config support and firmwarekey Configuration backups are automatically saved in the config directory 1 If necessary log on to the switch by Telnet using the admin account 2 You can choose to back up the the startup configuration or the running configuration or both To back up these configurations use the copy command These examples show backing up the configurations to a Brocade branded USB device a Insert the Brocade branded USB device into the USB port on the active management module b Enable the USB device by entering the USB on command c To back up the startup configuration enter copy startup config usb mystartupconfigdate The date porti
75. hassis 1 Orient the filler panel The MM SFM and line card filler panels must be aligned with the slot guides The power supply filler panels simply fit into the slots 2 Slide the filler panel into the slot until it is firmly seated The power supply panel may slide too far into the slot Insert it only until the facing matches the facing of the other power supplies or filler panels 3 Move the sliders and release the release pins The release pins should retract completely Chassis ID card removal and replacement 64 CID cards cannot be removed or replaced by customers If you experience a CID card failure call Brocade Technical Support When an error is detected you can run the CID Recovery Tool to pinpoint the problem and in some cases fix it If the problem is determined to be in the critical seeprom portion of the card no recovery is possible and you must contact Brocade Technical Support If however the problem is in the non critical seeprom it is possible that you can use the recovery tool to fix the problem See Table 16 for the various options for recovery To run the CID recovery tool enter the following command in Privileged EXEC mode Brocade VDX 8770 8 Hardware Reference Manual 53 1002564 03 SFP transceiver removal and replacement 5 sw0 cidrecov If the problem is in the critical seeprom the output indicates that you should call Brocade Technical Support If the problem is in the non critical seeprom
76. hassis is operating correctly Once a mismatch is detected an FFDC message is logged to this effect Additional error messages are generated until the problem is resolved If you experience a CID card failure call Brocade Technical Support Brocade VDX 8770 8 Hardware Reference Manual 53 1002564 03 Chapter Removal and Replacement Procedures 5 In this chapter A A aad Pate e ue aderat e qus 47 ESD TU el soi 4T e Cable management comb removal and replacement 48 Line card removal and replacement wa NI NEISES a STEEN rm rna 49 Management module removal and replacement lsususs 52 e Switch fabric module removal and replacement n nssnunanrnnnnnna 54 e Power supply removal and replacement o ooocococccccccccc Be Fan removal and replaceMe acacaciacavtavebsdces bared caine Rares 60 Air filter removal and replacement llli re vanes eee 62 e Module filler panel removal and replacement 63 e Chassis ID card removal and replacement o ooococoocccccnc oo 64 e SFP transceiver removal and replacement cece eee 65 e QSFP transceiver removal and replacement eee eeee 67 Cable Outing fable EE AERA Aa E 68 Introduction NOTE Read the safety notices before servicing Safety notices The field replaceable units FRUs in the Brocade VDX 8770 8 can be removed and replaced without special tools The Brocade VDX 8770 8 can continue operating during many of the FRU replacements if the con
77. he Brocade Switch supplier Slow flashing amber on 2 seconds then off 2 seconds Module is not seated correctly or is faulty Pull the module out and reseat it If the LED remains amber replace the module Fast flashing amber on 1 2 second then off 1 2 second Environmental range exceeded Check for the out of bounds environmental condition and correct it 10 GbE Port No light LED is off Status 48x10G line card or 1 GbE Port Status 48x1G line card 38 The port is disabled Verify that the power LED is on check the transceiver and cable Steady green The port is online but has no traffic No action required Flickering green The port is online with traffic flowing htrough the port No action required Steady amber The port is receiving light but it is not online yet Reset the port by issuing a shutdown and no shutdown sequence on the port Slow flashing amber on 2 seconds then off 2 seconds The port is disabled Enable the port by issuing a no shutdown command Fast flashing amber on 1 4 second the off 1 4 second The transceiver or port is faulty Change the transceiver or reset the port by issuing a shutdown and no shutdown sequence Slow flashing green on 2 seconds then off 2 seconds The port is online but segmented either a loopback cable or incompatible switch connection Consult the Troubleshooting
78. he following steps to determine the status of a power supply Check for the out of bounds environmental condition and correct it 1 Check the alarm LED labeled ALM on the power supply refer to Figure 9 The LED patterns may temporarily change during POST and other diagnostic tests for information about how to interpret the LED patterns refer to Table 13 The Brocade VDX 8770 8 can have up to eight power supplies Be sure to check each module 2 Check the power supply status by entering show environment power rbridge id rbridge id Refer to Table 12 for possible results from this command You can also use the show system command Figure 9 shows a power supply rr O EDS EOS ES CS CA e ak COL OE OC oC DEA Ole eS OODODOOUO El 2 AD O SSS Sa a cok OC OCOCOCOCOCOCOCOC ET PO OO OOOO COCOCOQOSCOCOCOCOCOCOC 1 AC power input LED AC OK 2 DC power output LED DC OK FIGURE 9 Power supply Brocade VDX 8770 8 Hardware Reference Manual 53 1002564 03 3 Alarm LED ALM 43 4 Determining the status of a fan TABLE 12 Output for show environment power command Output Explanation OK Power supply is functioni
79. hy eee eens 58 Removal and replacement of the fan 2 0 00 ccc eee eee 61 Removal and replacement of the air ner 62 Optical transceiver extraction tool 66 Optical transceiver with bail open 66 QSFP cable and transceiver with bail open 68 Brocade VDX 8770 8 Hardware Reference Manual 53 1002564 03 Brocade VDX 8770 8 Hardware Reference Manual 53 1002564 03 Tables Table 1 Table 2 Table 3 Table 4 Table 5 Table 6 Table 7 Table 8 Table 9 Table 10 Table 11 Table 12 Table 13 Table 14 Table 15 Table 16 Table 17 Table 18 Table 19 Table 20 Table 21 Table 22 Table 23 Table 24 Table 25 Line cards available for the Brocade VDX S rO8 selle 5 Installation tasks time and items reouired 00 cee ee eee ee eee 9 Power specification Ss sssini osia a nnn 13 Power demands per COMPONEN 000 eee eee eee eee eee 14 Environmental requirementS o ococcccoccc nananana 15 Windows serial connection parameters ooococcocococc eee 23 Serial cable pinouts esses EE ELE RENE KEES KN ER e de ER 23 Default administrative account names and passwords 24 Line card LED descriptions 38 Management module LED description 40 Switch fabric module LED descriptions 00 eee eee eee 42 Output for show environment power Commande 44 Power supply LED descriptions 00 00 ccc eee eee eee ee 44 Output for show environment fan command 000 e cee eee eee 45 Fan LED descriptions s
80. ical products that do not comply with these standards might emit light that is hazardous to the eyes Safety agency approvals e CAN CSA C22 2 No 60950 1 07 UL60950 1 Second Edition Safety of Information Technology Equipment e EN 60825 1 Safety of Laser Products Part 1 Equipment Classification Requirements and User s Guide e EN 60825 2 Safety of Laser Products Part 2 Safety of Optical Fibre Communications Systems e EN 60950 1 2006 IEC 60950 1 2005 Second Edition Safety of Information Technology Equipment Regulatory compliance standards Table 25 lists the regulatory compliance standards for which the Brocade VDX 8770 8 is certified TABLE 25 Regulatory compliance standards Country Standards Agency Certifications and Markings Safety EMC Safety EMC United States Bi Nat UL CSA60950 1 ANSI C63 4 cCSAus FCC Class A and 2nd Ed or latest Statement Canada Bi Nat UL CSA 60950 1 ICES 003 Class A cCSAus ICES A and Statement 2nd Ed or latest 80 Brocade VDX 8770 8 Hardware Reference Manual 53 1002564 03 Environmental regulation compliance A TABLE 25 Regulatory compliance standards Continued Country Standards Agency Certifications and Markings Safety EMC Safety EMC Japan CISPR22 and JEIDA VCCI A and Statement Harmonics European Union EN60950 1 2nd Ed or EN55022 and TUV GS N CE marking latest EN55024 Australia New Zealand EN55022 or CISPR22 C Tick mark or AS NZS CISPR22 Argentina IEC60950 1
81. itch must be able to access The Pv4 address variable is optional By default this value is LOCL which uses the local clock as the clock server switch config ntp server 132 163 135 131 To display the NTP server IP address use the show ntp status rbridge id rbridge id all command If you are in config mode you must use do before the show command switch config do show ntp status rbridge id 1 The request is for the local switch unless an Rbridge ID is specified Specify the all parameter to send the request to all switches in the cluster If you need to remove an NTP server use the no form of the ntp server command switch config no ntp server 132 163 135 131 Setting the time zone You must perform this procedure on all switches for which the time zone must be set However you only need to set the time zone once on each switch because the value is written to nonvolatile memory While not necessary for switch operation setting a time zone is part of ensuring accurate logging and audit tracking Time zone changes persist through a reboot without having to save the current running config Use the clock timezone command to set the time zone 1 If necessary log in to the switch using an account assigned to the admin role Be sure you are in privileged EXEC mode 2 Enter the clock timezone region city command The following example changes the time zone to US Pacific Standard Time switch clock timezone America Los
82. ith the Brocade VDX 8770 8 Items required Refer to the proper rack mount kit instructions TABLE 2 Installation tasks time and items required Continued Installation task Time estimate Installing the rack mount kit 30 minutes Mounting and securing Brocade VDX 30 minutes 8770 8 in the rack for your specific rack Inserting modules and power supplies 5 10 minutes per unit Management modules switch fabric modules line cards power supplies AC or DC A A Items included with the Brocade VDX 8770 8 10 Installing power cables and powering on 20 minutes Power cables provided in the Brocade VDX the Brocade VDX 8770 8 8770 8 accessory kit Establishing a serial connection loggingon 20 minutes Serial cable also called the console cable to the Brocade VDX 8770 8 and provided in the accessory kit configuring the IP addresses Workstation computer with a serial console port or terminal server port and a terminal emulator application such as HyperTerminal Ethernet IP addresses for the Brocade VDX 8770 8 switch and for management modules total two or three addresses depending on the number of management modules installed Installing an Ethernet cable opening a 20 minutes Ethernet cabling optional for Telnet access Telnet session and configuring the Brocade VDX 8770 8 date and time and additional system parameters Verify and back up configuration Refer to the Brocade Network OS Ad
83. ler panel removal and replacement 5 Time and items required The replacement procedure for the air filter takes less than five minutes Be sure to have the following items available e Anew air filter e A 2 Phillips screwdriver Removing an air filter Complete the following steps to remove an air filter from the chassis 1 While holding the air filter in place unscrew the four captive mounting screws using the 2 Phillips screwdriver 2 Carefully remove the air filter from the chassis To avoid having captured particulates drawn into the chassis remove the filter in a fashion that maintains the orientation of the filter relative to the system until the filter is 12 inches away from the intake Replacing an air filter Complete the following steps to mount the new air filter on the chassis 1 Orient the new filter over the four mounting holes using the screws as guides Be sure the side marked BOTTOM is on the bottom 2 Usingthe 2 Phillips screwdriver initiate the threads two turns per screw until all four are started 3 Tighten all four screws one at a time Do not overtighten the screws as this will compromise the frame admitting unfiltered air Module filler panel removal and replacement This section describes how to remove and replace module filler panels Each removable module in the chassis except the fans has a matching filler panel that must be in place if no module is installed in a slot This include
84. line card modules Ports are numbered from 1 through 48 from top to bottom with the odd numbered ports on the right row and the even numbered ports on the left row when installed in the switch Refer to Figure 4 FIGURE 4 48x10G line card 48x1G line card similar Providing power to the Brocade VDX 8770 8 Complete the following steps to provide power to the chassis Each power supply has one power cord A DANGER Use the supplied power cords Ensure the facility power receptacle is the correct type supplies the required voltage and is properly grounded D004 18 Brocade VDX 8770 8 Hardware Reference Manual 53 1002564 03 Providing power to the Brocade VDX 8770 8 2 Connecting an AC power cord 1 2 3 Plug the power cord into the power supply Route the cable so it will be out of the way when connected to the power source Plug the other end of the cable into the power source Connecting a DC power cord 1 Use a 1 Phillips screwdriver to remove the screw that secures the safety cover over the power lugs and remove the safety cover Use a 2 Phillips screwdriver to unscrew the power lugs Crimp the 2 AWG power supply wires into the power lugs Connect the power lugs to the power supply unit Connect the 48V wire to the negative terminal and the OV wire to the positive terminal NOTE The DC return must be isola
85. ministrator s Guide Installing transceivers as needed 30 60 minutes up to 30 seconds per transceiver Copper and optical transceivers and direct attach cables as needed Attaching cables cable ties and cable guides CAUTION 2 3 hours Cables cable ties and cable comb The Brocade VDX 8770 8 with DC power sources are intended for installation in restricted access areas only A restricted access area is a location where access can be gained only by service personnel through the use of a special tool lock and key or other means of security and is controlled by the authority responsible for the location CAUTION The Brocade VDX 8770 8 with AC power sources are intended for installation in restricted access areas only A restricted access area is a location where access can be gained only by service personnel through the use of a special tool lock and key or other means of security The basic Brocade VDX 8770 8 SKUs BR VDX8770 8 BND AC or BR VDX87 70 8 BND DC depending on whether you order AC or DC power supplies ships with the following items Brocade VDX 8770 8 Hardware Reference Manual 53 1002564 03 Items included with the Brocade VDX 8770 8 2 e Brocade VDX 8770 8 chassis populated with Management modules one Switch fabric modules six Filler panels for unoccupied slots for all modules Power supplies up to three Power supply filler panels for unoccupied bays Fan assemblies fo
86. mmand 30 crossover cable 32 91 customizing chassis name 27 host name 27 D danger statements translated 87 distributed intelligence 22 E environmental regulation compliance 81 Ethernet fabric 22 Ethernet ports 71 Ethernet establish connection 26 event date and time 28 F fan replacing 60 status 44 fan LEDs 46 FCC warning US only 78 field replaceable units See FRUs filler panel replacing 62 63 FRUs cable management comb replacing 48 fan 44 LEDs 46 replacing 60 filler panel replacing 62 63 line card replacing 49 MM LEDs 40 replacing 52 power supply 43 LEDs 44 replacing 57 QSFP transceivers replacing 67 SFM LEDs 42 replacing 54 SFP 32 transceivers replacing 65 weights 72 FTP backing up via 31 92 G Gigabit NICs 32 H hardware components 2 high availability 5 host name customizing 27 length 27 humidity requirement 15 installation items required 13 SFP 32 tasks 9 installed licenses 30 international power cords 74 inter switch links see ISLs ip address command 25 ip gateway address command 25 ISLs 34 K KCC statement Republic of Korea 79 L laser compliance 80 latency port to port 71 LEDs fan 46 line card 38 MM 40 power supply 44 SFM 42 license chassis software 30 line card determining status 35 replacing 49 Brocade VDX 8770 8 Hardware Reference Manual 53 1002564 03 line card LEDs 38
87. n Installation of the Brocade VDX 8770 8 to check your power requirements Disconnect the power supply from the power source Use a 1 Phillips screwdriver to remove the screw that secures the safety cover over the power lugs Remove the safety cover Use a 2 Phillips screwdriver to unscrew the power lugs Loosen the captive screw underneath the latch handle on the power supply faceplate Push down on the handle to eject the power supply Grasp the handle and pull sliding the power supply from the chassis and supporting the power supply from beneath as you remove it Replacing a DC power supply If you are not replacing the power supply insert a filler panel into the slot To replace a DC power supply complete the following steps 1 Unpack the new power supply and remove it from the anti static bag 2 Inspect the power supply for damage 3 Use a 1 Phillips screwdriver to remove the screw that secures the safety cover over the power lugs Remove the safety cover 4 Ensure that the handle of the replacement power supply is rotated down 5 Insert the power supply into the slot 6 Rotate the handle upward to fully seat the power supply T Tighten the captive screw ATTENTION This equipment installation must meet NEC CEC code requirements Consult local authorities for regulations Brocade VDX 8770 8 Hardware Reference Manual 59 53 1002564 03 5 Fan removal and replacement Fan removal and replacement Use this procedur
88. n to the serial console port Logging in to the serial console port Log in to the Brocade VDX 8770 8 through the serial connection with the admin user name The default password is password While you are not required to change the password at the initial login Brocade recommends that you change your admin and user passwords Refer to Assigning permanent passwords for more details Make sure to write down the new passwords and keep this information in a secure location Network OS 8770HOST 8770HOST console login admin Password WARNING The default password of admin and user accounts have not been changed Welcome to the Brocade Network Operating System Software admin connected from 127 0 0 1 using console on 8770HOST 8770HOST Changing the RBridge ID If you are going to have more than one switch in a fabric each switch must have a unique RBridge ID The default RBridge ID for any Brocade VDX 8770 8 is 1 Use the ves rbridge id rbridge id command to change the default RBridge ID You should be in privileged EXEC mode to run the command Enter the ves rbridge id rbridge id command switchf ves rbridge id 2 This operation will change the configuration to default and reboot the switch Do you want to continue y n y When the confirmation question appears answer Y The reply to command will include a line about the setting of the RBridge ID Successfully set rbridge id Assigning permanent passwords 24
89. nd Commands are printed in bold option option Command options are printed in bold argument arg Arguments Optional element variable Variables are printed in italics In the help pages values are underlined or enclosed in angled brackets lt gt Repeat the previous element for example member member value Fixed values following arguments are printed in plain font For example show chassis Boolean Elements are exclusive For example show mode egress ingress Command examples This book describes how to perform configuration tasks using the Network OS command line interface but does not describe the commands in detail For complete descriptions of all Fabric OS commands including syntax operand description and sample output refer to the Network OS Command Reference Notes cautions and warnings The following notices and statements are used in this manual They are listed here in order of increasing severity of potential hazards NOTE A note provides a tip guidance or advice emphasizes important information or provides a reference to related information ATTENTION An Attention statement indicates potential damage to hardware or data An CAUTION A Caution statement alerts you to situations that can be potentially hazardous to you or cause damage to hardware firmware software or data A DANGER A Danger statement indicates conditions or situations that can be potentially lethal or
90. ng correctly absent Power supply is not present Could also be improperly seated unknown Unknown power supply unit installed predicting failure Power supply is present but predicting failure faulty Power supply is present but faulty no power cable power switch turned off fuse blown or other internal error Could also be improperly seated For absent or faulty indications if the power supply is not improperly seated contact the Brocade VDX 8770 8 supplier to order replacement parts You may also want to do this if the indication is predicting failure Table 13 describes the power supply LED patterns and the recommended actions for those patterns TABLE 13 Power supply LED descriptions LED purpose Color Status Recommended action AC OK No light Power supply does not have If using AC power ensure that the LED is off incoming AC power power supply is firmly seated the AC power source is live and the power cable is connected Steady green Power supply has incoming AC No action required power DC OK No light The DC output is not in the Ensure that the power supply is LED is off acceptable range firmly seated Steady green The DC output is in the No action required acceptable range ALM No light The power supply has not failed No action required LED is off Steady amber The power supply has failed Replace the power supply Determining the status of a fan Complete the following steps to determine the s
91. ngle chassis delivering up to 384 10 Gbps or 1 Gbps Ethernet GbE ports or 96 40 Gbps Ethernet ports Two slots for management modules Asingle active management module can control all ports in the chassis The standby management module takes control of the Brocade VDX 8770 8 if the active management module fails six slots for switch fabric modules that interconnect all line cards Modular hot swappable field replaceable units FRUS 48x10GDbE line card 48x1GbE line card 12x40GbE line card Four fan assemblies Upto eight 3000W power supplies 200 240 VAC auto sensing or 48 VDC each power supply connection should be separately fused The 48x10GbE line cards support 10 GbE SFP and 1 GbE SFP optical transceivers as well as 1 GbE copper SFP transceivers They also support direct attach 10 GbE copper twinax cables at 1 3 or 5 meters The 12x40GbE line card supports 40 GbE QSFP optical transceivers Cable management comb Brocade VDX 8770 8 Hardware Reference Manual 53 1002564 03 Brocade VDX 8770 8 hardware components 1 Port side of the Brocade VDX 8770 8 NOTE Airflow in the Brocade VDX 8770 8 is from the port side to the rear fan side of the chassis Figure 1 displays a sample configuration of the port side of the Brocade VDX 8770 8
92. nk is healthy and No action required management traffic is flowing through port link activity upper right No light LED is off No traffic is flowing No action required Brocade VDX 8770 8 Hardware Reference Manual 53 1002564 03 Determining the status of a switch fabric module 4 Determining the status of a switch fabric module At least one functional switch fabric module SFM must be plugged into slots S3 or S4 the control plane slots If there are no functional SFMs in either slot during bootup bootup is halted with a messsage indicating that condition In an operational chassis if all SFMs in the control plane slots become faulty or are removed then all the line cards will be faulted with a reason code that indicates no availability of an SFM An external raslog message will also be displayed Complete the following steps to determine the status of an SFM 1 Checkthe LED indicators on the SFM refer to Figure 8 The LED patterns may temporarily change during POST and other diagnostic tests For information about how to interpret the LED patterns refer to Table 11 2 Youcan use the show sfm command or the show slots command to see whether the SFM is enabled Brocade VDX 8770 8 Hardware Reference Manual 41 53 1002564 03 4 42 Determining the status of a switch fabric module Figure 8 identifies the switch fabric module
93. ole on the input lugs to the power supply The input wiring for the connection to the switch should be copper wire 2 American Wire Guage AWG marked VW 1 and rated minimum 90 C The power requirements for a given switch configuration depend on which modules have been installed in the switch Table 4 shows the power consumption for the modules that can be used in the Brocade VDX 8770 8 switch along with the power consumption for the cooling fans All numbers for the line cards assume that the card is fully populated with optical transceivers including QSFPs for the 12x40 GbE line cards All ports are Ethernet You can calculate your power requirements by combining the power demands for the various modules and fan units in your configuration While you may use fewer ports in a given line card it is always safer to use the power requirement of a fully populated card TABLE 4 Power demands per component Module or fan units Power demand atidle Nominal power demand Maximum power demand blades blades enabled no blades enabled optics 50 enabled optics traffic present full line optics ports disabled line rate random packets rate 64 byte smallest packet 40 C Watts Watts ambient temp maximum power for all supported optics Watts Management module 46 46 50 Switch fabric module 120 120 132 48x1G line card 245 310 460 48x10G line card 245 310 460 12x40G line card 247 290 440 Fan unit 25 25 268 CAUTION Fo
94. on of the target file name should be the current date to indicate when the backup was made For example copy running config usb myrunningconfig06142012 d To back up the running configuration enter copy running config usb myrunningconfigdate Alternatively you can save the configuration files to a remote host using either FTP or SCP The destination file argument would be either ftp username passwordGhost ip address path filename or scp username passwordOhost_ip_address path filename respectively Specifying a path is optional As with the USB examples be sure to append the date to the target file name ATTENTION Passwords are not saved in the configuration file and are not uploaded during a configuration upload Brocade VDX 8770 8 Hardware Reference Manual 31 53 1002564 03 3 Connecting network devices NOTE Brocade recommends that the configuration be backed up on a regular basis to ensure that a complete configuration is available for downloading to a replacement management module or Brocade VDX 8770 8 Be sure to append the date to the end of the target file names to make it clear which are the latest backups Connecting network devices You can connect your chassis to a variety of network devices Refer to the topics below for some specific requirements for making these conections Connecting to Ethernet devices For copper connections to a 10 100Base TX or 1000Base T switch or another Brocade device a crossover cabl
95. operate maintain and troubleshoot the Brocade VDX 8770 8 It is organized in loosely chronological order beginning with an overview of the Brocade VDX 8770 8 and ending with removal and replacement procedures of field replaceable units FRUS The document contains the following sections Chapter 1 Brocade VDX 8770 8 Overview identifies the components of the Brocade VDX 8770 8 and provides a brief description of its features Chapter 2 Installation of the Brocade VDX 8770 8 describes how to install set up and power on the Brocade VDX 8770 8 Chapter 3 Logging In and Configuring the Brocade VDX 8770 8 provides the initial configuration information required to get the Brocade VDX 8770 8 up and running Chapter 4 Monitoring System Components provides descriptions of the LEDs and their functions and also lists Network OS commands required for monitoring Chapter 5 Removal and Replacement Procedures describes how to remove and replace each of the FRUs in the Brocade VDX 8770 8 Appendix A Specifications provides information on the physical characteristics environmental requirements and regulatory certifications for the Brocade VDX 8770 8 Appendix B Caution and Danger Notices contains a list of the translated Caution and Danger messages Brocade VDX 8770 8 Hardware Reference Manual xiii 53 1002564 03 Supported hardware and software This document includes information specific to the Brocade VDX
96. ossible qu au personnel de service utilisant un verrou une cl ou un outil sp cial ou d autres moyens de s curit PRECAUCI N Todos aquellos dispositivos con fuentes de alimentaci n de CA est n dise ados para su instalaci n en zonas de acceso restringido solamente Una zona de acceso restringido es un lugar al que s lo puede acceder personal de mantenimiento haciendo uso de una herramienta especial una llave y un candado o alg n otro medio de seguridad CAUTION For a Brocade VDX 8770 8 AC system use a ground wire of at least 2 American Wire Gauge AWG The ground wire should have an agency approved crimped connector provided with the chassis attached to one end with the other end attached to building ground The connector must be crimped with the proper tool allowing it to be connected to both ground screws on the enclosure VORSICHT F r ein Wechselstromsystem Brocade VDX 8770 8 ist ein Erdleiter von mindestens 2 AWG amerikanische Norm f r Drahtquerschnitte zu verwenden An einem Ende des Erdleiters sollte ein gepr fter gecrimpter Anschluss mit Chassis bereitgestellt angebracht sein Das andere Ende sollte an der Geb udeerdung angeschlossen werden Der Anschluss muss mit dem richtigen Werkzeug gecrimpt werden so dass er an beiden Erdungsschrauben am Geh use angeschlossen werden kann MISE EN GARDE Pour un syst me alimentation secteur Brocade VDX 8770 8 utiliser un c ble de mise la ter
97. ows the current configuration to remain available even if the active MM fails The configuration information for the Brocade VDX 8770 8 is stored in the CID cards and the flash memory of the MMs The configuration can be backed up to a workstation uploaded and then downloaded to the active MM if necessary By default the Product Name is in VCS mode It cannot be configured in standalone mode Without a VCS license the switch can be part of a two node cluster where two switches are connected in VCS mode to form an Ethernet fabric To be part of a larger cluster you must install a VCS license In VCS mode the switch is part of an VCS fabric involving two or more VCS enabled switches VCS technology embodies the concept of distributed intelligence Distributed intelligence means that all configuration and destination information is automatically distributed to each member switch in the fabric Distributed intelligence has three major characteristics e The fabric is self forming When two or more VCS enabled switches with unique Rbridge IDs are connected to form an VCS fabric the fabric is automatically created and the switches discover the common fabric configuration e The fabric is masterless No single switch stores configuration information or controls fabric operations Any switch can fail or be removed without causing disruptive fabric downtime or delayed traffic e The fabric is aware of all members devices and Virtual Machines VM
98. ports in line card modules e Dual redundant management modules MM e Up to six switch fabric modules SFM e Up to eight redundant hot swappable power supplies at 220 VAC or 48 VDC e Up to four hot swappable fan assemblies e Serial console Ethernet and USB connections for management modules NOTE USB support is for Brocade branded USB devices only e Support for short wavelength SX and long wavelength LX 1 Gbps SFP transceivers Brocade VDX 8770 8 Hardware Reference Manual 1 53 1002564 03 1 Brocade VDX 8770 8 hardware components Support for SR and LR 10 Gbps SFP transceivers Support for 40 Gbps QSFP transceivers Support for active twinaxial twinax cable at 1 3 and 5 meters for 10 GbE ports NEBS compliant chassis certification in process Support for in band management 15U form factor for chassis Support for Brocade trunking through the 48x10G line card module maximum of eight ports per trunk Support for Fibre Channel over Ethernet FCoE Brocade VDX 8770 8 hardware components The Brocade VDX 8770 8 features a modular and scalable mechanical construction that allows a wide range of flexibility in installation fabric design and maintenance The minimum chassis configuration is one MM one SFM and one line card The chassis can be mounted with the cables facing the front of the equipment rack and consists of the following components Eight slots for hot swappable line cards that can be configured in a si
99. r Notices ln thiSAppendiX ee ve ee a ee ee ee en 85 Caution NOtICES ss sceleri etter eee eee NEEN EN EEN EN 85 Danger notes ti LIS Ens Rob eR areas Janta fed ated 87 vii viii Brocade VDX 8770 8 Hardware Reference Manual 53 1002564 03 Figures Figure 1 Figure 2 Figure 3 Figure 4 Figure 5 Figure 6 Figure 7 Figure 8 Figure 9 Figure 10 Figure 11 Figure 12 Figure 13 Figure 14 Figure 15 Figure 16 Figure 17 Figure 18 Figure 19 Figure 20 Figure 21 Port side of the Brocade VDX 8770 8 sample configuration 3 Nonport side of the Brocade VDX 8770 8 sample configuration 4 12x40G MECA i eda cen dccem cog Rec Red sca ccc e CR ec 17 48x10G line card 48x1G line card ema 18 48x10G line card full view and dose upl 0c 36 12x40G line card full view and dose up ccc eee eee eee 37 Management module 0 0c eect tees 40 Switch fabric module seu kem E ncm oe x REX CRIEXG REX ERA 42 Power supply EE 43 Fan module ui eye REY RR Yee Te aie are EN CR a ce RH ER ane 45 Removal and replacement of the cable management comb 49 Removal and replacement of a line card 48x10G card shown 51 Removal and replacement of the management module aan assnnnsannuas 53 SEM FROME VIEW s s iania a roria EUR ce on ges x m ac ROS ROCKS RUNI ER CR wie dence wit EN SEKR 55 Removal and replacement of the switch fabric module 56 Removal and replacement of the power supp
100. r the NEBS compliant installation of a Brocade VDX 8770 8 with AC or DC systems use a ground wire of at least 2 AWG The ground wire should have an agency approved crimped connector provided with the device attached to one end with the other end attached to building ground The connector must be crimped with the proper tool allowing it to be connected to both ground screws on the enclosure Before crimping the ground wire into the provided ground lug Brocade VDX 8770 8 Hardware Reference Manual 53 1002564 03 Preparing for the Brocade VDX 8770 8 installation 2 ensure that the bare copper wire has been cleaned and antioxidant is applied to the bare wire In addition anti rotation devices or lock washers must be used with all screw connections for the grounding wire Environmental requirements A DANGER Do not install the router in an environment where the operating ambient temperature might exceed 40 C 104 F Table 5 lists the environmental operating ranges for the Brocade VDX 8770 8 The requirements for non operating conditions are also provided for acceptable storage and transportation environments TABLE 5 Environmental requirements Condition Acceptable range during operation Acceptable range during non operation Ambient temperature 0 to 40 C 32 to 104 F outside 25 to 70 C 13 to 158 F outside switch Switch Humidity 5 to 90 RH noncondensing at 40 C 10 to 90 RH noncondensing
101. re Reference Manual 53 1002564 03 Establishing a serial connection to the Brocade VDX 8770 8 3 If the serial port on the workstation or terminal device is DB9 instead of RJ 45 remove the adapter on the end of the serial cable and insert the exposed DB9 connector into the DB9 serial port on the workstation ATTENTION The serial port is intended primarily for the initial setting of the IP address and for service purposes 4 Disable any serial communication programs running on the workstation such as synchronization programs 5 Open a terminal emulator application such as HyperTerminal on a PC or TERM TIP or Kermit in a UNIX environment and configure the application as follows e na Windows environment use the following parameters TABLE 6 Windows serial connection parameters Parameter Value Bits per second 9600 Data bits 8 Parity None Stop bits 1 Flow control None e naUNIX environment enter the following string at the prompt tip dev ttyb 9600 If ttyb is already in use use ttya instead and enter the following string at the prompt tip dev ttya 9600 Table 7 lists the serial cable pinouts TABLE 7 Serial cable pinouts PIN Signal Description 1 Not supported NA 2 Not supported NA 3 TXD Transmit data 4 GND Logic ground 5 Not supported NA 6 RXD Receive data 7 Not supported NA 8 Not supported NA Brocade VDX 8770 8 Hardware Reference Manual 23 53 1002564 03 3 Logging i
102. re de calibre AWG 2 25 mm minimum Ce fil de terre doit tre quip d un c t d un connecteur sertir agr fourni avec le ch ssis et l autre extr mit doit tre reli e la terre du b timent Ce connecteur doit tre serti l aide de l outil appropri afin d tre raccord aux deux vis de mise la terre du boitier PRECAUCI N Para un sistema de CA Brocade VDX 8770 8 utilice un conductor de tierra de al menos 2 CAE Calibre de Alambre Estadounidense American Wire Gauge o AWG en sus siglas en ingl s El conductor de tierra debe tener un conector rizado homologado suministrado con el chasis acoplado a un extremo y el otro extremo debe estar conectado a la tierra del edificio El conector debe rizarse con la herramienta apropiada de manera que se conecte a los dos tornillos de tierra del recinto Danger notices A danger calls your attention to a possible hazard that can cause injury or death The following are the dangers used in this manual Gefahr weist auf eine m gliche Gef hrdung hin die zu Verletzungen oder Tod f hren k nnen Sie finden die folgenden Warnhinweise in diesem Handbuch Un danger attire votre attention sur un risque possible de blessure ou de d c s Ci dessous vous trouverez les dangers utilis s dans ce manuel Una advertencia le llama la atenci n sobre cualquier posible peligro que pueda ocasionar da os personales o la muerte A continuaci n se dan las advertenci
103. s Automatic Migration of Port Profiles AMPP supports VM migration to another physical server If the VM moves it is automatically reconnected to all of its original resources Establishing a serial connection to the Brocade VDX 8770 8 22 The serial port is located on the port side of the Brocade VDX 8770 8 The switch uses an RJ 45 connector for the serial port An RJ 45 to DB9 adapter is also provided with the Brocade VDX 8770 8 The cable supplied with the switch is a rollover cable The serial port is used to connect to a workstation to configure the Brocade VDX 8770 8 IP address before connecting the switch to a fabric or IP network NOTE To protect the serial port from damage keep the cover on the port when not in use To establish a serial connection to the serial console port on the Brocade VDX 8770 8 complete the following steps 1 Verify that the Brocade VDX 8770 8 is powered on and that POST is complete by verifying that all power LED indicators on the management switch fabric and line card modules display a steady green light 2 Remove the shipping cap from the serial port labeled IOIOI on the active MM By default the MM installed in slot M1 is the active MM unless an error occurs The active MM is also indicated by an illuminated blue LED labeled ACTIVE 3 Usethe serial cable provided with the Brocade VDX 8770 8 to connect the serial port on the active MM to a computer workstation Brocade VDX 8770 8 Hardwa
104. s 90 C bemessen sein MISE EN GARDE Pour le circuit d alimentation en courant continu du syst me Brocade VDX 8770 8 3000W supply v rifier la pr sence d un disjoncteur bipolaire homologu de 80 A minimum 48 Vcc sur l entr e de l alimentation Les c bles d alimentation du produit doivent tre des fils de cuivre homologu s de section 10 mm 4 AWG marqu s VW 1 et test s 90 C 86 PRECAUCI N verifique que existe un disyuntor catalogado por UL de 80 amperios 48VCC como m nimo Para el circuito de entrada de CC al sistema de un Brocade VDX 8770 8 3000W supply bipolar en las orejetas de entrada a la fuente de alimentaci n El cableado de entrada para la conexi n al producto deber ser de cable de cobre catalogado 4 AWG marcado con VW 1 y tener una capacidad nominal m nima para 90 C CAUTION Do not install the device in an environment where the operating ambient temperature might exceed 40 C 104 F VORSICHT Das Ger t darf nicht in einer Umgebung mit einer Umgebungsbetriebstemperatur von ber 40 C 104 F installiert werden MISE EN GARDE N installez pas le dispositif dans un environnement o la temp rature d exploitation ambiante risque de d passer 40 C 104 F PRECAUCI N No instale el instrumento en un entorno en el que la temperatura ambiente de operaci n pueda exceder los 40 C 104 F CAUTION Use a separate branch circuit for each AC power cord
105. s LED 2 Power LED 4 10GbE port FIGURE 5 48x10G line card full view and close up Brocade VDX 8770 8 Hardware Reference Manual 53 1002564 03 Determining the status of a line card 4 i X 40GF fr o Z O gol sz o e o so o vy O wolooleo 1 Status LED 3 PortStatus LED 2 PowerLED 4 4OGbE port FIGURE 6 12x40G line card full view and close up Brocade VDX 8770 8 Hardware Reference Manual 37 53 1002564 03 4 Determining the status of a line card Table 9 describes the line card LED indications and the recommended actions for those patterns TABLE 9 LED purpose Power LED o Line card LED descriptions Color No light LED is off Status Module is not powered on Recommended action Ensure that the module is firmly seated and either the thumbscrew is fully engaged or the slider is pushed up and the ejectors are fully engaged Steady green Module is powered on No action required Status LED No light LED is off Module is healthy or is not powered on Verify that the power LED is on Steady amber Module is faulty Ensure that the module is firmly seated and check the status by entering the show slot command If the LED remains amber consult t
106. s management modules switch fabric modules line cards and power supplies There are no filler panels for the fans since all fans must be installed on the chassis NOTE The filler panels have release pins and sliders to hold them in place Brocade VDX 8770 8 Hardware Reference Manual 63 53 1002564 03 5 Chassis ID card removal and replacement Removing a filler panel Complete the following steps to remove a filler panel from the chassis ATTENTION A filler panel should be removed only when being replaced with a new module or another filler panel Any slot that is not occupied by a module should be occupied by a filler panel to ensure correct cooling of the chassis and protection from dust Filler panels for the MM and SFM are the same The filler panel for the line card slot is similar though larger Both the MM SFM panels and line card panels have two release pins and sliders The filler panel for the power supply slot is quite different having only one release pin and slider 1 Pullthe release pin or pins out and simultaneously move the slider or sliders The entire face of the power supply filler panel is a slider and it moves upward to release the panel The sliders for the MM SFM and line card filler panels move toward the center of the panel to release it 2 Pullthe filler panel out of the chassis using the release pins Replacing a filler panel Do not leave a slot empty This will adversely affect cooling of the c
107. s section describes how to remove and replace a switch fabric module SFM The Brocade VDX 8710 8 has up to six SFMs They can be installed only in slots S1 through S6 There must be at least one SFM installed in either slot S3 or slot S4 Refer to Figure 14 Time and items required The replacement procedure for the SFM takes approximately 10 minutes The following items are required for the SFM replacement e ESD grounding strap e Phillips 2 screwdriver e Replacement SFM Brocade VDX 8770 8 Hardware Reference Manual 53 1002564 03 Switch fabric module removal and replacement 5 1 Ejectors 5 Slider 2 Thumbscrews 6 Powerenable pin 3 Status LED 7 Slider screws 4 PowerLED FIGURE 14 SFM front view Removing a switch fabric module The Brocade VDX 8770 8 continues to operate while an SFM is being replaced Refer to Figure 15 for the following procedure ATTENTION Follow ESD precautions 1 Unscrew the power enable pin 2 Loosen the two screws on the slider using the Phillips screwdriver if necessary 3 Pull out the pin and move the slider all the way up exposing the captive screw 4 Unscrew the two captive screws using the Phillips screwdriver 5 Open the ejectors by rotating them toward the center of the module face Pull the SFM out of the chassis using the ejectors Brocade VDX 8770 8 Hardware Reference Manual 55 53 1002564 03 5 56 Switch fabric module removal and replacement
108. seated and the latching mechanism clicks Transceivers are keyed so that they can only be inserted with the correct orientation If a transceiver does not slide in easily ensure that it is correctly oriented Remove the protective plug from the transceiver 4 Position the cable so that the key the ridge on one side of the cable connector is aligned with the slot in the transceiver Insert the cable into the transceiver until the latching mechanism clicks Cables are keyed so that they can be inserted in only one way If a cable does not slide in easily ensure that it is correctly oriented Cable routing table Table 17 is a 48 port template for a cable routing table Make copies of the table to cover the total number of ports in the Brocade VDX 8770 8 TABLE 17 Cable routing table for the Brocade VDX 8770 8 48 ports shown Slot port Cable labels Connected device Slot port of device Slot Port Switch end Device end NJ O Oil A O N e 68 Brocade VDX 8770 8 Hardware Reference Manual 53 1002564 03 TABLE 17 Slot port Slot Cable routing table Cable routing table for the Brocade VDX 8770 8 48 ports shown Continued Cable labels Connected device Slot port of device Port Switch end Device end 8 5 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33
109. seconds The transceiver or port is faulty The port is online but segmented either a loopback cable or incompatible switch connection Beaconing used to identify specific ports Change the transceiver or reset the port by issuing a shutdown and no shutdown sequence Consult the Troubleshooting section of the Network OS Administrator s Guide No action required Fast flashing green on 1 2 second the off 1 2 second Internal loopback diagnostic Determining the status of a management module You must have at least one management module MM active for the chassis to be functional For redundancy you need two MMs The active MM is designated by the blue Active LED on the front panel Complete the following steps to determine the status of a MM In diagnostic mode Will return to regular mode when diagnostic is finished 1 Check the LED indicators on the module Figure 7 The LED patterns may temporarily change during POST and other diagnostic tests For information about how to interpret the LED patterns refer to Table 10 2 You can use the show mm command to see whether the management modules are enabled You can also run the show interface management 1 1 to see the configuration information Figure 7 identifies the management module Brocade VDX 8770 8 Hardware Reference Manual 53 1002564 03 39 4 Determining the status of a management module 10101
110. sis and the number of power supplies installed the Brocade VDX 8770 8 may be able to continue operating during the replacement Refer to Power specifications on page 13 to determine your power requirements If insufficient power is present the chassis will start powering down modules until the power demand can be met A DANGER Disconnect the power cords from all power sources to completely remove power from the chassis Time and items required The replacement procedure for each power supply takes less than five minutes e Anew power supply unit or filler panel is required for the power supply replacement e A 1 Phillips screwdriver e A 2 Phillips screwdriver Removing an AC power supply For the following procedure refer to Figure 16 To remove a power supply complete the following steps 1 Perform the appropriate following action based on whether the Brocade VDX 8770 8 is operating e If the Brocade VDX 8770 8 is not operating during the replacement procedure go to step 2 e If the Brocade VDX 8770 8 is operating and will continue to operate during the replacement check the power LEDs to verify that the minimum number of power supplies is functioning Refer to Table 3 and Table 4 in Installation of the Brocade VDX 8770 8 to check your power requirements 2 Unlatch the power cord retainer clip Remove the power cord Loosen the captive screw Brocade VDX 8770 8 Hardware Reference Manual 57 53 1002564 03
111. supplies and one cable management comb Empty chassis weight includes backplane cables bus bars power 61 24 kg 135 Ib distribution bus chassis ID card No management modules No switch fabric modules No line cards No power supplies No fans No cable management devices System component weights Table 21 lists the weights of the compatible modules and FRUs TABLE 21 System component weights FRU Weight Management module 2 25 kg 4 95 Ib Switch fabric module 2 61 kg 5 75 Ib 72 Brocade VDX 8770 8 Hardware Reference Manual 53 1002564 03 Ethernet port supported optics A TABLE 21 System component weights Continued FRU Weight 48x1G line card 5 85 kg 12 9 Ib 48x10 line card 5 85 kg 12 9 Ib 12x 40G line card 5 40 kg 11 9 Ib Power supply 2 88 kg 6 35 Ib Fan assembly 4 76 kg 10 5 Ib Cable management comb 0 41 kg 0 90 Ib Line card filler panel 1 72 kg 3 8 Ib MM SFM filler panel 98 kg 2 15 Ib Power supply filler panel 0 36 kg 0 8 Ib Ethernet port supported optics The Ethernet ports in the Brocade VDX 8770 8 support full duplex link speeds at 1 10 or 40 Gbps inbound and outbound Table 22 shows the optics supported in the line cards for the Brocade VDX 8770 8 TABLE 22 Supported optics Speed Maximum cable distance microns 1 GbE 850 MMF 62 5 220 m 721 8 ft 275 m 902 2 ft 500 m 1640 4 ft 550 m 1804 5 ft 550 m
112. sure that the air temperature on the air intake side is less than 40 C 104 F during operation Power specifications Power for the Brocade VDX 8770 8 can be supplied with either AC or DC based 3000 watt power supplies The Brocade VDX 8770 8 has room for up to eight power supplies Table 3 shows the basic power specifications for each power supply TABLE 3 Power specifications Specification Value for 3000W AC power supply Value for 3000W DC power supply Input rating 16A 70A Input voltage 200 240 VAC 50 60 Hz 16 0 Amp 48 VDC maximum Operating range 180 ot 264 VAC 40 to 60 VDC Brocade VDX 8770 8 Hardware Reference Manual 13 53 1002564 03 14 2 Preparing for the Brocade VDX 8770 8 installation TABLE 3 Power specifications Continued Specification Value for 3000W AC power supply Value for 3000W DC power supply Inrush current Limited to 60 Amp peak for any initial Limited to 70 Amp peak for any initial current surge or spike of 10 ms or less at current surge or spike of 10 ms or less at either cold or warm start Any additional either cold or warm start inrush current surges or spikes in the form of AC cycles or multiple AC cycles greater than 10 ms and less than 150 ms must not exceed 25 Amp peak Output 12 VDC 245 Amps 12 VDC 245 Amps A CAUTION For the DC input circuit to the system of a Brocade VDX 8770 8 3000W power supply make sure there is an 80 Amp circuit breaker minimum 48 VDC double p
113. t management module is active and a failover has already occurred Complete the following steps to remove a management module 1 2 3 4 Remove any cables connected to the module Unscrew the captive screws from both ejectors using the Phillips screwdriver Rotate both ejectors simultaneously toward the center of the module Pull the management module out of the chassis by the ejectors FIGURE13 Removal and replacement of the management module Brocade VDX 8770 8 Hardware Reference Manual 53 53 1002564 03 5 Switch fabric module removal and replacement Replacing a management module For this procedure please refer to ESD precautions and Figure 13 Complete the following steps to insert an MM Unpack the new MM and remove it from the anti static bag Inspect the module for damage Remove the protective caps from the b ackplane connectors Rotate the ejectors toward the center of the module Align the module pan with the guides in the slot The first MM should be installed in slot M1 Slide the MM into the slot until it is firmly seated Rotate the ejectors away from the center of the module face until the module is tight in the slot 0 Jm mb Wr Hp Tighten the captive screws using the Phillips screwdriver Switch fabric module removal and replacement 54 Thi
114. t Grounding Systems The Brocade VDX 8770 8 shall be installed and connected to the CBN IBN or Ether Communication Equipment Grounding The Brocade VDX 8770 8 is suitable for connection to the Central Office Bonding of Battery Return BR Input Terminals The battery returns of the Brocade VDX 8770 8 shall be connected as DCH Connections The Brocade VDX 8770 8 shall be grounded via a copper ground conductor Connections All bare grounding connection points to the Brocade VDX 8770 8 shall be cleaned and coated with an anti oxidant solution before connections are made Connections All surfaces on the Brocade VDX 8770 8 that are un plated shall be Brocade VDX 8770 8 Hardware Reference Manual 53 1002564 03 brought to a bright finish and treated with and anti oxidant solution before connections is made 77 A Regulatory compliance TABLE 24 NEBS installation requirements for the Brocade VDX 8770 8 Reference Warning requirement or statement Connections All non conductive surfaces on the Brocade VDX 8770 8 shall be removed from all threads and connection points to ensure electrical continuity Connections Brocade VDX 8770 8 utilizes a 2 hole compression type Agency approved crimped connector with a copper 2 American Wire Guage AWG that is utilizes 20 inch pounds of torque to secure it the frame and EUT Input DC Voltage The Brocade VDX 8770 8 is capable of operating at 200 240 V 50 60 Hz at a
115. tatus of a fan 1 Check the LED indicators on the fan refer to Figure 10 The LED patterns may temporarily change during POST and other diagnostic tests for information about how to interpret the LED patterns refer to Table 15 The Brocade VDX 8770 8 has up to four fans Be sure to check each module 2 Check the fan status using the show environment fan rbridge id rbridge id all command Brocade VDX 8770 8 Hardware Reference Manual 53 1002564 03 Determining the status of a fan 4 See Table 14 for possible results from this command The RPM of each fan is also provided If a fan displays absent or faulty contact the Brocade VDX 8770 8 supplier to order replacement parts Both physically absent or faulty could also be the result of the fan not being properly seated You can also use the show system command Figure 10 shows a fan unit CEN SC C RI C ATONE OES CEA CERO TO Kyte teks ORI i ene Se E E LCE t O Ji ade MUS O AS LACH LA III O Aoc FAUUN S N O 1 Power LED 2 Fault LED FIGURE 10 Fan module
116. ted from the chassis ground DC I when making connections to the connections to the power supply Replace the safety cover Plug the other end of the cable into the power source ATTENTION Do not connect the switch to the network until the IP addresses are configured For information about LED patterns see Chapter 4 Monitoring System Components Brocade VDX 8770 8 Hardware Reference Manual 19 53 1002564 03 20 2 Providing power to the Brocade VDX 8770 8 Brocade VDX 8770 8 Hardware Reference Manual 53 1002564 03 Logging In and Configuring the Brocade VDX 8770 8 Chapter 3 In this chapter e Preparing to configure the Brocade VDX 8770 8 0000 ee eee 21 e Establishing a serial connection to the Brocade VDX 8770 8 22 Logging in to the serial console port 2 0 2 0 00 SEENEN siran 24 Changing he RBNAZS A uou atre aec ada BAR i Rm dane manana 24 e Assigning permanent passwords 0c eee eee eee ee 24 e Configuring the IP addresses scrisse ee ve eis vo RR Rx REESE 25 Logging off the serial console port and disconnecting the serial cable 26 e Establishing an Ethernet connection to the Brocade VDX 8770 8 26 e Customizing a Host NAME au a wur es ARR ioe E CEEX ees 27 CUSTOMIZING a Chassis NIME soci See al ASSEN AEN NEEN eel RUE RAS 27 e Setting the date and tO usada aia ARAS 28 e Determining installed software licenses o o oooocoooooocooooo 30 SIE
117. the Technical Committee T11 website This website provides interface standards for high performance and mass storage applications for Fibre Channel storage management and other applications http www t11 org For information about the Fibre Channel industry visit the Fibre Channel Industry Association website http www fibrechannel org Brocade VDX 8770 8 Hardware Reference Manual 53 1002564 03 For information about the Ethernet industry visit the Internet Engineering Task Force website http www ietf org Getting technical help Contact your Brocade VDX 8770 8 supplier for hardware firmware and software support including product repairs and part ordering To expedite your call have the following information available 1 General information e Technical Support contract number if applicable e Model name e Operating system version Error numbers and messages received e Copy support command output e Detailed description of the problem and specific questions e Description of any troubleshooting steps already performed and results e Serial console and Telnet session logs e Syslog message logs Brocade VDX 8770 8 serial number The Brocade VDX 8770 8 serial number Switch Serial No and corresponding bar code are provided on the serial number label as shown here AINT ARA FTOOX0054E9 The serial number label is located on the nonport side of the chassis on the lower right side and directly below the fans In addi
118. the product contains the CE mark which indicates that this system conforms to the provisions of the following European Council directives laws and standards e Electromagnetic Compatibility EMC Directive 2004 108EEC e Low Voltage Directive LVD 73 23 EEC and the Complementary Directive 93 68 EEC e EN55022 2006 European Emissions Requirements e EN55024 1998 A1 2001 and A2 2003 European Immunity Requirements e EN61000 3 2 2006 JEIDA European and Japanese Harmonics Spec e EN61000 3 3 1995 A1 2001 and A2 2005 Brocade VDX 8770 8 Hardware Reference Manual 79 53 1002564 03 A Regulatory compliance Canadian requirements This Class A digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations ICES 003 Class A German statement Maschinenl rminformations Verordnung 3 GPSGV der h chste Schalldruckpegel betr gt 79 0 dB A gem ss EN ISO 7779 Machine noise information regulation 3 GPSGV the highest sound pressure level value is 79 0 dB A in accordance with EN ISO 7779 Laser compliance This equipment contains Class 1 laser products and complies with FDA Radiation Performance Standards 21 CFR Subchapter and the international laser safety standard IEC 825 2 Use only optical transceivers that are qualified by Brocade Communications Systems Inc and comply with the FDA Class 1 radiation performance requirements defined in 21 CFR Subchapter and with IEC 825 2 Opt
119. tings are not affected by Network Time Protocol NTP server synchronization The following regions are supported Africa America Arctic Antarctica Asia Atlantic Australia Europe Indian and Pacific One of these along with a city name establishes the time zone Refer to Setting the time zone Time synchronization To keep the time in your network current it is recommended that each switch has its time synchronized with at least one external NTP server All switches in the fabric maintain the current clock server value in nonvolatile memory By default this value is the local switch clock The ntp server command accepts multiple server addresses in either IPv4 or IPv6 format When multiple NTP server addresses are passed ntp server sets the first obtainable address as the active NTP server If there are no reachable time servers then the local switch time is the default time Synchronizing local time using NTP Perform the following steps to synchronize the local time using NTP 1 Log in to the switch using the default password the default password is password 2 Enter configure terminal to change to global configuration mode switch configure terminal Entering configuration mode terminal Brocade VDX 8770 8 Hardware Reference Manual 53 1002564 03 Setting the date and time 3 3 Enter the ntp server Pv4 address command where IPv4 address is the IP address of the first NTP server in IPv4 format which the sw
120. tion the show chassis command displays the Brocade VDX 8770 8 serial number as well as information about the line cards and other field replaceable units FRUs License ID World Wide Name WWN Use the show licenseid command to display the license ID WWN The licenselD WWN is recorded on the chassis identification CID cards If you cannot use the show licenseid command because the switch is inoperable you can get the WWN from the same place as the serial number Document feedback Quality is our first concern at Brocade and we have made every effort to ensure the accuracy and completeness of this document However if you find an error or an omission or you think that a topic needs further development we want to hear from you Forward your feedback to Brocade VDX 8770 8 Hardware Reference Manual xvii 53 1002564 03 documentation brocade com Provide the title and version number of the document and as much detail as possible about your comment including the topic heading and page number and your suggestions for improvement xviii Brocade VDX 8770 8 Hardware Reference Manual 53 1002564 03 Chapter Brocade VDX 8770 8 Overview 1 In this chapter Brocade YDA S7 et TROU ES uz i ao weap de Rea i qon ad RAS xd eae Cc t dla 1 e Brocade VDX 8770 8 hardware components 002ece eee ee eee 2 e Brocade YDA Si TUS ING BAIS acc eee ee eee is faa 5 MS ri E Grace TTE AA A 5 Software Tea ul es aaa aa adag p EE SCENE OEE
121. tion to a possible hazard that can damage equipment Vorsicht weist auf eine m gliche Besch digung des Ger ts hin Sie finden die folgenden Vorsichtshinweise in diesem Handbuch Une mise en garde attire votre attention sur un risque possible d endommagement de l quipement Ci dessous vous trouverez les mises en garde utilis es dans ce manuel Un mensaje de precauci n le advierte sobre un posible peligro que pueda da ar el equipo Las siguientes son precauciones utilizadas en este manual CAUTION All devices with DC power supplies Brocade VDX 8770 8 are intended for installation in restricted access areas only A restricted access area is where access can be gained only by service personnel through the use of a special tool lock and key or other means of security and is controlled by the authority responsible for the location VORSICHT Alle Ger te mit Direktstromquellen Brocade VDX 8770 8 sind nur zur Installation in Sperrbereichen bestimmt Ein Sperrbereich ist ein Ort zu dem nur Wartungspersonal mit einem Spezialwerkzeug Schloss und Schl ssel oder einer anderen Schutzvorrichtung Zugang hat Er unterliegt au erdem der Kontrolle durch die f r den Standort verantwortliche Stelle MISE EN GARDE Tous les quipements dot s d un bloc d alimentation en courant continu Brocade VDX 8770 8 sont concus pour l installation dans des zones acc s r glement uniquement Une zone acc s r glement est un local qui n
122. up to 31 username command 25 UTP cable 32 V VCCI statement 79 VCS 1 VCS mode 22 vcs rbridge id command 24 VCS trunking 34 verify configuration 31 vibration requirement 15 W weight chassis 72 modules 72 Brocade VDX 8770 8 Hardware Reference Manual 53 1002564 03
123. ur e Accessory kit containing the following items Console cable RS 45 serial cable There is also an adapter that can be used to provide an DB9 style connector Wrist strap ESD grounding strap Ground lug kit SFP extraction tool kit China RoHS guide Cable management comb Brocade branded USB device Power cord retainer kit Brocade VDX 8770 8 QuickStart Guide this publication Hardware for securing the switch in a rack Web pointer document Air filter Line cards up to 8 and additional power supplies must be ordered separately The rack mount kits must be ordered separately Brocade branded transceivers SFP SFP or QSFP and cables or direct attach cables must also be ordered separately The Brocade VDX 8770 8 supports SR and LR SFP and SFP transceivers The QSFP transceivers are SR transceivers only NOTE For information about the transceivers that are qualified for the Brocade VDX 8770 8 refer to http www brocade com downloads documents matrices Brocade Compatibility Matrix pdf Brocade VDX 8770 8 Hardware Reference Manual 11 53 1002564 03 2 Preparing for the Brocade VDX 8770 8 installation Preparing for the Brocade VDX 8770 8 installation NOTE Refer to the safety notices before installation Safety notices Refer to NEBS requirements to ensure compliance with NEBS GR 1089 standards Refer to Power specifications to plan for meeting power supply standards before installing the chassis Ref
124. use mr eR A tae ee 46 Options for the CID Recovery Tool 65 Cable routing table for the Brocade VDX 8770 8 48 ports shown 68 General specifications oooooooccoccnorr eee 71 System architecture 6k ehh ra 71 System size and weight i cece cece sus eee ehh ea x ee a EEN e 72 System component weightS 0 00 eee eee nen 72 Supported Optics sky AA AA ae ae a 73 Power cord types international llle 74 NEBS installation requirements for the Brocade VDX 8770 8 77 Regulatory compliance standards llli iere 81 Brocade VDX 8770 8 Hardware Reference Manual 53 1002564 03 xi Xii Brocade VDX 8770 8 Hardware Reference Manual 53 1002564 03 About This Document In this chapter How this document is organized AEN seo tea enr rh re ee xiii e Supported hardware and software 00 ccc eee eee xiv e Whats new wu TiS GENEE ANE EE dor pO CORRER EO AER CA EUR ROLE AN ERR xiv e Document CONVENTIONS eci trt terrere rn eters hee ne ber ER ORT DE OORT RR xiv diss tO MIS SNES Parvo nae eB se i xvi Additional informiatiorkessaw sper rc AAA xvi e Getting technical help ca e TREIER EE EELER EE ERE EY xvii sl su a ac de letters tp Enea cra recens Set dou cu adu M CR xvii How this document is organized This document is a hardware reference manual written for system administrators and technicians experienced with networking and IP technologies to help them install set up configure