Home
ATTO FastStream VT 5700 Installation and Operation
Contents
1. ATTO Technology Inc FastStream VT 5700 Installation and Operation Manual Use the serial port To connect to a terminal emulation program or Telnet to manage the FastStream VT 5700 use the serial port 1 Connecta cable from FastStream VT 5700 RS 232 serial port or header to the serial COM port on a personal computer 2 Turnon the FastStream VT 5700 3 Start a terminal emulation program on the personal computer and use it to connect to the FastStream VT 5700 For example if you are using HyperTerminal on a computer running a Windows operating system a Type FastStream VT 5700 in the New Connection dialog box Click OK c Inthe Connect To dialog box for the Connect using field select the COM port number to which your serial cable is connected Click OK In the COM Properties dialog box select the following values Bits per second 115200 e Data Bits 8 Parity None e Stop Bits 1 e Flow Control None e Terminal type ASCII Use Telnet Up to three Telnet sessions can be conducted simultaneously A serial port session can use the CLI while Telnet sessions are open Whichever session issues the first set CLI command can continue to issue set commands while the other sessions can only issue get commands or display information Once a connection is established refer to CLI provides an ASCH based interface on page v of the Appendix 1 Connect to the FastStream VT 5700 from a computer on th
2. Decide whether to use FTP over Ethernet or a terminal program using the RS 232 serial link and continue with one of the following procedures Use FTP over Ethernet 1 Establish an FTP link to the ATTO FastStream VT that is to be flashed 2 Use the PUT command to download the firmware For example PUT c firmware FS5300100 IMA 3 Once the download is complete cycle power on the ATTO FastStream VT to implement the new firmware Use the RS 232 serial link 1 Load a Terminal Program such as Hyper Terminal Set the terminal and the ATTO FastStream VT for the highest possible baud rate for your terminal Turn on power to the ATTO FastStream VT Once the Ready prompt appears type ZMODEM RECEIVE The ATTO FastStream VT displays that it is preparing to receive a file from your terminal program On the terminal program choose Transfer Send File In the Send File box type in the current ATTO FastStream VT ima file or click the browse button to find it Click Send File The ATTO FastStream VT should acknowledge receiving the file and display a message not to interrupt power for 90 seconds Once the download is complete cycle power on the ATTO FastStream VT to invoke the new firmware 26 6 0 Interface options The best way to manage monitor and configure the FastStream VT 5700 is to use the ExpressNAV interface but you may use a terminal emulation program or Telnet The ExpressNAV interface is the p
3. get Time TimeZone Controls or displays the time zone or an offset from GMT for the unit set TimeZone EST CST MST PST HH MM Requires a SaveConfiguration command get TimeZone xvii Username Specifies the user name used for all sessions NDMP Telnet FTP and ExpressNAV Username is case insensitive 1 to 32 characters and cannot contain spaces Default root set Username user name Requires a SaveConfiguration command get Username VerboseMode Controls the level of detail in CLI Help output and command response output for the current CLI session Default enabled set VerboseMode enabled disabled get VerboseMode Voltage Displays the voltage levels monitored by the FastStream Representations of the voltages are VDDA 3 31 V VDDB 2 49 V VDDC 1 5V VDDD 1 35V ALL all monitored voltages get Voltage VDDA VDDB VDDC VDDD all VTLCaplnfoNotify Specifies what percentage of total storage capacity used triggers an informational level notification is sent to the user The valid range is 50 percent to 75 percent Default 75 set VTLCaplnfoNotify percentage get VTLCaplnfoNotify VTLCapWarnNotify Specifies what percentage of total storage capacity used triggers a warning notification is sent to the user The valid range is 75 percent to 90 percent Default 90 set VTLCapWarnNotify percentage get VTLCapWarnNotify ATTO Technology Inc FastStream VT 5700 Installation and Opera
4. ATTO ATTO Technology Inc ATTO FastStream VT 5700 Installation and Operation Manual Fibre Channel to Fibre Channel Virtual Tape Appliance 2007 ATTO Technology Inc All rights reserved All brand or product names are trademarks of their respective holders No part of this manual may be reproduced in any form or by any means without the express written permission of ATTO Technology Inc 3 2007 PRMA 0385 000 Contents 1 0 ATTO FastStream VT 5700 increases reliability 1 Hardware features Virtual Tape features Backup and restore features Management and control features 1 1 Physical attributes urea ee ewes 3 Dimensions Cooling and airflow Power Fibre Channel ports Ethernet port Serial port Reset restore factory default switch LED indicators 2 0 Installationi piega 5 Unpack the packing box verify contents Install the FastStream Install Windows drivers Discover the IP address Internet Explorer setup Begin initial configuration 2 1 Configure Virtual Tape rrrrrin 7 Initialize and verify drives Use quick initial configuration Use custom setup 2 2Use Hot Spares c uiii ila 11 2 3 Optional system modifications 1 13 Customize the user name password Change system configurations Customize other parameters using the Advanced CLI page Discover manage other ATTO devices Create a
5. Display Clear drive BlockDevID all running MinOpTemp Regulates the minimum operating temperature of this unit in degrees Celsius Valid entries are between 0 C and 15 C Default 0 set MinOpTemp 0 15 Requires a SaveConfiguration Restart command get MinOpTemp OpTempWarn Regulates the number of degrees Celsius before a thermal control event precipitates a warning to the user Valid entries are between 0 C and 15 C Default 0 set OpTempWarn 0 15 Requires a SaveConfiguration Restart command get OpTempWarn PartitionDisplay Lists all the partitions available in the specified RAID group The partitions are listed in order of contiguousness as opposed to index order PartitionDisplay GroupName ATTO Technology Inc FastStream VT 5700 Installation and Operation Manual Password Specifies password for all non serial sessions Telnet ftp and FastStream browser based user interface You are prompted for the current password to type the new password and to confirm the new password If local echo is enabled password echoes all characters In verbose mode only CLI requests the password be re typed When the password is all 0s Telnet and ftp do not validate the password and MDS authentication is disabled Passwords are case sensitive and can be 1 32 characters long with no spaces Default Password set Password Requires a SaveConfiguration command Performance Returns the performance
6. Partitions amp Partition Configuration l Drives amp 3 ee W Drives Configuration Drive Health J _ System Scan Port 3 Drives 17 10GB 17 10GB 17 10GB 17 10GB Hot Spare ONLINE ONLINE ONLINE Port 4 Drives 1 0GB 1 0GB 1 0GB 1 0GB 1 0GB ONLINE ONLINE ONLINE ONLINE ONLINE 2002 2006 ATTO Technology Inc Phone home E mail messages E mail notification allows the FastStream VT to immediately while less serious error messages send an E mail message to you a network are sent every 15 minutes administrator or other users when certain events Conditions which may launch E mails include occur Serious error messages are sent Device errors e Device transitions from online to offline 17 ATTO Technology Inc FastStream VT 5700 Installation and Operation Manual e Temperature conditions e Voltage conditions e Power recycle power failure e VTL nearing space capacity Warning levels include All warnings critical events and informational messages are sent e Critical critical event E mails are sent e Warning warnings and critical event E mails are sent e Informational information only is sent e None no E mails are sent You may send E mails to up to five E mail addresses and designate which conditions prompt each E mail notification When an event occurs that warrants E mail notification the FastStream VT sends the message it cannot respond to a rejection b
7. Be sure to back up data before performing verification A CAUTION Data is erased during this process Back up your data before selecting Commit These operations have a negative impact on the performance of normal operations all activity should be stopped 1 Follow the instructions in Preliminary steps on page 19 2 Clickthe Initialize and Verify button Click Next 4 Click on the drives you wish to test the drives are highlighted oO 19 5 Select Verify Only 6 Click Commit 7 A warning message displays choose yes to continue 8 The Drive Performance and Health screen appears The Time Remaining box tells you how much time remains until the verification process is complete The representation of each drive in the Drives box shows the percentage of verification completed Scan drive surfaces read only drive test The read only test performs a non destructive scan over the entire surface of each drive to identify bad areas of the disk drives and determine read performance It may be run while data is passing through the FastStream Running this test may negatively impact performance Once the test has completed system operation returns to normal 1 Follow the instructions in Preliminary steps on page 19 2 Click the Read Only Drive Test button Select User Process O initialize and Verify Drives Read Only Drive Test Drive Performance and Health O Identify Drive O clean RAID Configuration Data Click
8. 32 drives per JBOD configured RAID group Exhibit A 1 JBOD Just a Bunch of Disks no redundancy each disk is treated independently JBOD Disk 0 Disk 1 Disk 2 DO D4 D8 D1 D5 D9 D2 D6 D10 D3 D7 D11 RAID Level 0 RAID Level 0 striping is based on the fact that increased performance can be achieved by simultaneously accessing data across multiple drives increasing data transfer rates while reducing average access time by overlapping drive seeks RAID Level 0 groups provide data that is striped across several drives Drives are accessed alternately as if stacked one on top of the other RAID Level 0 provides no data protection If one drive fails all data within that stripe set is lost The ATTO FastStream VT 5700 supports 2 to 32 drives per RAID Level 0 group RAID Level 0 is used by applications requiring high performance for non critical data Exhibit A 2 RAID Level 0 no redundancy RAID Level 0 Stripe Disk 0 Disk 1 Disk 2 Disk 3 Disk 4 Disk 5 0 DO D1 D2 D3 D4 D5 D6 D7 D8 D9 D10 D11 1 2 D12 D13 D14 D15 D16 D17 3 D18 D19 D20 D21 D22 D23 ATTO Technology Inc FastStream VT 5700 Installation and Operation Manual RAID Level 1 RAID Level ensures the security of data by writing the exact same data simultaneously to two or more different drives This application is for users with critical data which cannot be lost or corrupted
9. D8 D8 3 D9 D9 D10 D10 D11 D11 RAID Level 5 RAID Level 5 increases reliability while using fewer drives than mirroring by employing parity redundancy Distributed parity on multiple drives allows you to rebuild a failed drive from the remaining good drives The ATTO FastStream VT 5700 operates in degraded mode if a drive fails The ATTO FastStream VT 5700 supports 3 to 16 drives per RAID Level 5 group Exhibit A 5 RAID Level 5 with parity blocks shaded RAID Level 5 Stripe Disk 0 Disk 1 Disk 2 Disk 3 Disk 4 Disk 5 0 DO D1 D2 D3 D4 P0 4 D6 D7 D8 D9 P5 9 D5 D12 D13 D14 P10 14 D10 D11 D18 D19 P15 19 D15 D16 D17 D24 P20 24 D20 D21 D22 D23 P25 29 D25 D26 D27 D28 D29 aj A j N gt Appendix C CLI provides an ASCll based interface The command line interface CLI uses ASCII commands typed while in CLI mode A CAUTION e The get form returns the value of a parameter or setting and is an informational command Do notuse CL unless You are dinectedite e Responses to get commands are followed by by an ATTO technician Ready Changing parameters may cause loss of e The set form is an action that changes the value data and or disruption to performance and ae of a parameter or configuration setting It may reliability of the FastStream require a SaveConfiguration command and a The ExpressNAV interface is the preferred restart of the
10. Move Virtual Tape cartridges The Move Medium page is an interface which simulates a generic library front panel operation 1 Follow Preliminary steps on page 21 and click on the Manage button 2 The Manage VTL page appears Choose the Virtual Tape Libraries arrow Click in the Move Medium button Click on Next The Move Medium page appears Click on the tab with the name of the Virtual Tape Cartridge for which you wish to move medium 6 Click on the radio button next to the Virtual Tape Cartridge element you wish to move 7 Click on the radio button next to the new place where you want the Virtual Tape Cartridge element Click Commit The Move Medium page appears 0 If you wish to move other VTL cartridge elements repeat this procedure oR Ww 1 Follow Preliminary steps on page 21 and click on the Manage button 2 The Manage VTL page appears Select the RAID Groups drop down arrow 3 Click on Add Drives to a RAID Group 4 Click on Next 5 Select the RAID group associated with the VTL you wish to add the drives to from the drop down menu 6 Click on the drives you wish to add to the RAID group A CAUTION Adding drives to an existing RAID group may adversely impact performance You cannot reverse this operation unless you delete the RAID group 7 When you have completed your changes click on Commit 22 A CAUTION During this procedure do not power down the host or the ATTO FastStream VT until
11. Next Choose the drives you wish to test Click Commit A warning message displays choose yes to continue 7 The Drive Performance and Health screen appears with the Drive Metrics box displaying basic information about the drives Click on the Show Help Text and Drives arrow 8 Ifadriveis being read its display shows the percentage of progress When the test is complete click on each drive to see its information highlighted in the Drive Metrics window ou W ATTO Technology Inc FastStream VT 5700 Installation and Operation Manual x Note If you close the browser or navigate away from this page you may re access these results by clicking the Diagnostics button and choosing the Drive Performance and Health option Results are available until the FastStream is restarted Measure drive performance and health New performance data is updated every 60 seconds which impacts performance slightly even if you minimize the browser window Exit the ExpressNAV interface completely whenever you need maximum performance During the testing process the Drive Performance and Health screen appears Click on Show Help Text and Drives for an alternative view of the test progress During the tests the Time Remaining box tells you how much time remains until the verification process is complete The representation of each drive in the Drives box shows the percentage of verification completed When the test is complete click o
12. SerialPortBaudRate SerialPortEcho Controls if the unit echoes characters on its RS 232 port When enabled all non control character keyboard input is output to the display Default enabled set SerialPortEcho enabled disabled get SerialPortEcho SNTP Controls whether an SNTP time server is used to set the FastStream time Default enabled set SNTP enabled disabled Requires a SaveConfiguration Restart command get SNTP xvi SNTPServer Controls or displays the main IP address the client uses to retrieve the SNTP time Default 192 43 244 18 set SNTPServer Xxx xxx XXX XXX Requires a SaveConfiguration Restart command get SNTPServer TailEventLog Displays new events to the terminal Type quit and press Enter to exit tail mode TailEventLog TapeLibDelete Deletes the specified tape library or all tape libraries TapeLibDelete GroupName all TapeLibInfo Lists information for the specified tape library or all tape libraries TapeLibInfo LibName all TapeWriteProtect Controls write protection for a particular virtual tape or both virtual tapes set TapeWriteProtect Tape Vol ID all enabled disabled get TapeWriteProtect Temperature Displays the current internal operating temperature of this unit in degrees Celsius get Temperature Time Controls or displays the current time as clocked by the unit in 24 hour format Time cannot be set if SNTP is enabled set Time HH MM SS
13. and Status Monitor page 1 If you are not already in the ExpressNAV interface type the IP address of your appliance as found in Use the ExpressNAV interface on page 27 in a standard browser click Enter Here and type in your user name and password The Monitor VTL page appears On the menu at the left hand side of the page click on Monitor The Health and Status Monitor page appears See Exhibit 3 0 2 If you click Details added information about each parameter Exhibit 3 0 2 The Health and Status Monitor page appears on the Configuration Display page See Exhibit 3 0 3 e RAID Groups RAID group names RAID status available Hot Spares and number of faulted drives Partition information e Environmental Status Temperature and voltage Interface Status Ethernet management port link status and Fibre Channel port link speed and connection mode Drive Status by port Size and status ATTO FASTSTREAM VT HEALTH AND STATUS MONITOR RAID Group Status RAID Group Hame Barb1 Status Menu Items ONLINE VTL Monitor Manage Diagnostics Hot Spares Available 3 Number Spent Hot Spares 0 Powered by Temperature 29 C 0C 70C ATTO Voltage Status GOOD Advanced _ retin Status Interface Status a Ethernet Management Port 1 Link Up Fibre Channel Port 1 Link Down Speed auto Mode loop Fibre Channel Port 2 Link Down Speed auto Mode loop Fibre Channel Port
14. and airflow Operating Temperature 0 40 C external Humidity 10 90 non condensing Airflow air enters through slots on the right of the rear panel and exits through slots on the left of the rear panel A CAUTION Do not block the enclosure s vents The FastStream VT 5700 does not allow data transfer if overheating occurs Power Input voltage 100 240VAC 1 7 7A 50 60 Hz Battery backed event log A rechargeable Lithium ion battery cell holds the event log memory for up to 30 days If the FastStream VT 5700 has been disconnected from power recharging begins automatically when power is restored to the system The battery is fully charged after 36 hours of continuous power application A WARNING Risk of explosion if battery is removed and or replaced by an incorrect type Dispose of used batteries in accordance with your local environmental regulations 3 AX warnunc Explosionsgefahr wenn die Batterie falsch entfernt und oder ersetzt wird Entsorgen Sie benutzte Batterien in Ubereinstimmung mit Ihren lokalen Umweltschutzbestimmungen Fibre Channel ports The four independent 4 Gigabit Fibre Channel ports connect the FastStream VT 5700 to either a Fibre Channel Fabric or Fibre Channel Arbitrated Loop using Small Formfactor Pluggable SFP interface and multimode fiber optic cable Make sure all cables are anchored securely at both ends with the proper connectors Use the shortest possible cable length for best p
15. command BlockDevidentify Causes the I O LED of the drive to illuminate for one minute if it is accessible A CAUTION The BlockDevidentify command is intended for diagnostic purposes only Executing this command may adversely impact the performance and throughput of the FastStream for the time that the LED is illuminated BlockDevldentify lt GroupName gt BlockDevID Member Index ix BlockDevIDStop Turns off the IO LED of a previously identified disk drive BlockDevIDStop BlockDevScan Lists all currently connected physical drives along with any potential RAID group association Each block device listed is assigned a unique index at the time of the scan to identify drives for other CLI operations Include the flush parameter to force discovery of all block devices The flush parameter also forces existing RAID groups offline until member block devices are discovered BlockDevScan lt flush gt BridgeModel Reports model information about the FastStream get BridgeModel BridgeName Allows you to specify an eight character name to an individual FastStream unit It is not the World Wide Name The string is alphanumeric eight characters long Default set BridgeName name get BridgeName ClearEventLog Clears the contents of the event log No new entries are recorded until the command has completed ClearEventLog Date Regulates the current date for this unit The possible date range is 1 1 2000 to 1
16. due to the failure of a single drive With RAID Level 1 the host sees what it believes to be a single physical drive of a specific size it does not know about the mirrored pair The ATTO FastStream VT 5700 manages where data is written and read allowing one drive to fail without the host knowing it has failed RAID Level 1 is used in applications containing mission critical data The ATTO FastStream VT 5700 supports an even number of 2 to 32 drives per RAID Level 1 group Exhibit A 3 RAID Level 1 Data is written to two or more drives simultaneously RAID Level 1 Stripe Disk 0 Disk 1 Disk 2 Disk 3 Disk 4 Disk 5 0 DO DO D4 D4 D8 D8 1 D1 D1 D5 D5 D9 D9 2 D2 D2 D6 D6 D10 D10 3 D3 D3 D7 D7 D11 D11 RAID Level 10 RAID Level 10 increases data transfer rates while ensuring security by writing the exact same data simultaneously to two or more different drives It is often described as a stripe of mirrors without parity RAID Level 10 is used in applications requiring high performance and redundancy combining the attributes of RAID Levels 1 and 0 The ATTO FastStream VT 5700 supports an even number of 4 to 32 drives per RAID Level 10 group Exhibit A 4 RAID Level 10 with mirroring and spanning redundancy is shown in shaded blocks RAID Level 10 Stripe Disk 0 Disk 1 Disk 2 Disk 3 Disk 4 Disk 5 0 DO DO DI D1 D2 D2 1 D3 D3 D4 D4 D5 D5 2 D6 D6 D7 D7
17. index is assigned to each target which is used with the fp to specify a Fibre Channel target for a subsequent Route CLI command FCTargets lt fp gt FCWWName Reports the Word Wide Name WWN of the FC interface Each FC port has an individual and unique WWN The least significant 3 bytes of the WWN are used as the Ethernet MAC address The lower nibble of the highest byte designates the port number get FCWWN fp all FirmwareRestart Resets and reinitializes the unit firmware Use the forced option to override any CLI reservations held by other sessions FirmwareRestart lt forced gt Help Displays a list of available commands If command name is specified displays detailed command specific information Help lt command name gt HSAdd Assigns a block device to the Hot Spare pool HSAdd BlockDevID HSDisplay Lists all devices in the Hot Spare pool HSDisplay HSRemove Removes a block device from the Hot Spare pool HSRemove BlockDevID xii IdentifyBridge Enabling this option causes the front panel Ready LED of the FastStream to blink until the parameter is disabled Default disabled set IdentifyBridge enabled disabled get IdentifyBridge Info Displays version numbers and other production information for key components Info IPAddress Regulates the current FastStream IP address If IPDHCP is enabled see below get command reports the current IP address assigned by the network DHCP se
18. interface used in this manual Designation Indicates a range 6 9 6 7 8 9 required entry n end of line pick one of lt gt optional entry BlockDevID index designation of a block device not assigned to any other RAID group fl Fibre Channel lun number 0 lt fl lt 31 fp Fibre Channel port number 1 lt fp lt 4 Member Index index designation of a RAID group member GroupName ASCII name of a RAID group the name of the RAID group to which the block device is assigned or blank if the block device is available mp1 Ethernet port used to manage the FastStream VT 5700 ATTO Technology Inc FastStream VT 5700 Installation and Operation Manual CLI error messages The following error messages may be returned by the Command line Interface ERROR Invalid Command Type Help for command list ERROR Wrong Missing Parameters Usage lt usage string gt ERROR Invalid RAID Group state ERROR Invalid Block Device index ERROR Invalid RAID Member index ERROR Maximum number of RAID Groups exceeded ERROR Insufficient number of RAID Group members ERROR Block Device at specified index no longer available ERROR Insufficient RAID Group members for RAID type CLI summary The following chart summarizes the Command Line Interface commands their defaults and an example of how to enter the commands Commands which have no default values have a blank entry in that column of t
19. storage space within a RAID group The act of breaking a single large data transfer into several smaller individual data transfers across a storage protocol Physical block devices of an arbitrarily sized set which are acted upon as a group using a single RAID algorithm A block device assigned to a RAID group The number of block devices concatenated to behave logically as a single RAID member A bus Storage Area Network SAN or other topology on which storage devices are attached A set of RAID groups associated with virtual tape drives and a virtual media changer whose storage is divided into virtual tape volumes A logical simulation of a tape volume using a subset of addressable storage space within a RAID group assigned to a tape group A logical simulation of a Sequential Access tape device associated with a tape group and that reads data from and writes data to virtual tape volumes within the tape group A logical simulation of a media changer associated with a tape group permits the assignment of specific virtual tape volumes of the tape group to specific virtual tape drives within the tape group ATTO Technology Inc FastStream VT 5700 Installation and Operation Manual Appendix B Designing RAID groups The ATTO FastStream VT 5700 provides instant hardware data protection and intelligence to existing Fibre Channel storage independent of the storage type A CAUTION Selecting RAID configuration causes all previous storage d
20. terminal type vt100 5 Type in the default values for the user name root and the password Password if you did not set new values in Discover the IP address on page 5 28 Appendix A Glossary Familiarity with the following terms may be useful Other sources for terms used in storage applications may be found at Term Definition Bridge LUN Virtual Tape Appliance LUN for processor functionality CLI Command Line Interface A set of ASCll based commands which perform Heterogeneous block devices Hot Spare Logical Unit LUN LUN Mapping Partition Partial Data Transfer RAID Group RAID Member Span Depth Storage Network Tape Group Virtual Tape Volume Virtual Tape Drive Virtual Media Changer configuration and diagnostic tasks Refer to Interface options on page 27 and CLI provides an ASCll based interface on page v of the Appendix Block devices which may be comprised of different protocols vendors products and capacities but must have the same block size A block device reserved to replace a failed member of a RAID group by assuming the role and contents of the failed member Refer to Use Hot Spares on page 11 A target device that implements a device model and manages tasks to process commands sent by an application client Logical Unit Number A 64 bit identifier for a logical unit The ability to map a virtual media changer and tape drives to specific LUNs A subset of addressable
21. the Health and Status Monitor page displays Any interruption of power while storage is being reorganized results in the loss of data 8 In the warning box verify that you want to add the drives to the RAID group by clicking on Yes Clicking on No ends the procedure without making a change 9 The Health and Status Monitor page appears Rebuild RAID groups If you receive an E mail notification from the FastStream VT as set up previously using the Phone Home error notification refer to Phone home E mail messages on page 17 or otherwise realize a drive has failed and you do not have available drives in the Hot Spares pool refer to Use Hot Spares on page 11 follow this procedure to replace the failed drive and manually begin a rebuild operation If you have available drives in the Hot Spare pool any failed drive is replaced by a Hot Spare automatically 1 Follow Preliminary steps on page 21 and click on the Diagnostics button 2 The Diagnostics page appears Click on Identify Drive Click Next Click on the degraded drive Click Commit The LED on the degraded drive flashes oo Aa WwW TY Note The status of a drive which cannot be accessed is displayed as Unavailable To identify this drive observe the access lights for all drives in the RAID group during disk access if the LED is not flashing on a drive it is the unavailable drive 7 When you have identified the failed drive select the drive in the
22. to define your virtual storage as if it were a physical tape storage array based on the needs of your ISV You may select a library to emulate or select Custom to define your own setup Step 4 VTL Configuration Select Library to Emulate ADIC Scalar 100 E Tape Bar Code Prefix i g ADIC Scalar 100 Media Type Sun StorageTek L180 Quantum PX500 Series Media Changer Vendor ID n Spectra Logic 20K Media Changer Product ID Overland NEO Series Media Changer Revision 0001 Tape Drive Vendor ID QUANTUM Tape Drive Product ID SDLT320 Tape Drive Revision 0001 e If you select a library default values for that library are entered into the fields in the rest of Step 4 and in Step 5 e Ifyou select Custom you must complete the fields in Step 4 and Step 5 on the screen However some fields may be populated automatically for you depending on your system 8 When you have completed your choices click Next 9 The Virtual Tape Library Setup page appears If the new configuration is the way you want it click on Commit 10 In the warning box verify that you want to add the VTL by clicking on Yes Ue Note j Clicking on No returns you to the Virtual Tape Library Setup page and you can choose to begin this procedure again Click on the Cancel button Click on the Manage menu item on the left Select the Virtual Tape Libraries arrow Click on the Create Virtual Tape Library button Continue wi
23. 0 on a stable flat surface or install it into a standard rack If installing into a rack a Attach L brackets so that the front side with the LEDs face front and the connector side is at the back See Exhibit 2 0 1 b Install the FastStream horizontally within the rack so it does not reduce the air flow within the rack Using SFPs and multimode fiber optic cables connect the FastStream Fibre Channel ports 1 and 2 to your host computer and ports 3 and 4 to your devices see Exhibit 1 1 2 on page 4 Keep cable lengths as short as possible to ensure the highest signal quality and performance refer to Fibre Channel ports on page 3 Connect the Ethernet port to your network Connect the AC power cord from the FastStream to the proper AC source outlet If you are using a rack a Properly ground the FastStream to the rack equipment The earth ground connection must be maintained b The power requirements plus the power draw of the other equipment in the rack must not overload the supply circuit and or wiring of the rack Use the power switch and switch on power to the FastStream Wait up to two minutes for the FastStream Ready LED to light indicating the FastStream has completed its power on self test sequence Windows users continue to Install Windows drivers Mac users continue to Discover the IP_ address Install Windows drivers 1 DQUIDSWN Windows automatically detects the FastStream
24. 2 31 2099 Default 01 01 2000 set Date MM DD YYYY get Date ATTO Technology Inc FastStream VT 5700 Installation and Operation Manual Defaultinterleave Assigns or retrieves the system default interleave size for new RAID groups If an interleave size is not explicitly specified when a RAID group is created then the DefaultInterleave value is used instead Default 128 set DefaultInterleave 16 32 64 128 256 get DefaultInterleave DeleteAllMaps Removes all mapped devices from the map table Upon the subsequent POST the default maps are loaded if no maps are present DeleteAllMaps SaveConfiguration command required DHCPFixedDelay Selects displays the delay in seconds between DHCP client request intervals from between 0 seconds to 255 seconds 0 time is typical Default 0 no delay set DHCPFixedDelay 0 255 Requires a SaveConfiguration command get DHCPFixedDelay DisplayEventLog Displays the EventLog The event log may be filtered using the DisplayEventLogFilter command The optional parameter n is the number of lines to be displayed as a single page with no user interaction After the command has executed use or to scroll through the log Type quit and press Enter to exit the command DisplayEventLog lt n gt DisplayEventLogFilter Filters the display of data for specified subsystems and levels during DisplavEventLog mode Valid event log subsystem entries are platform depend
25. 3 Fibre Channel Port 4 Link Up Speed 2Gb Mode loop Details gt gt Drive Health _ System Scan Drive Status I Port 3 Drives 2002 2006 ATTO Technology Inc 16 Configuration Display page Clicking on Details in the Health and Status Drives Monitor page gives you added information about Drive Configuration by port including drive size each parameter on the Configuration Display and Stas n Interfaces a a aaa i voy he detis Ethernet management port link status and Fibre Channel port link speed connection mode RAID Groups Node Name and Port Name RAID group names RAID status available Hot Spares number of faulted drives RAID Level Interleave and total capacity of each RAID group Exhibit 3 0 3 The Configuration Display page ATTO FASTSTREAM VT ATTD Technology Inc CONFIGURATION DISPLAY The status information is from 18 21 16 11 06 2006 To monitor current status information click the Monitor button a onthe menu This takes you to the Status and Health Monitor which displays the current status and updates Menu Items automatically every 60 seconds VIL Monto RAID Groups n W RAID Group Configuration Manage _ RAID RAID Humber Total Humber Diagnostics RAID Group Name Status Level Partitions Interleave Capacity Drives Barbi ONLINE RAIDS 1 64 0KB 14 29GB 16 Advanced j Powered by Hot Spares Available 3 Number Spent Hot Spares 0
26. Identify Drive box to stop the LED flash TX Note It is best practice to stop drive activity while changing drives 8 Remove the failed drive from the array Insert the new drive into the array 10 Inthe ExpressNAV interface click the Manage button 11 Click the arrow next to RAID Groups 12 Select Rebuild RAID Groups 13 Click Next 14 Atthe Step 1 Select a RAID group select Degraded Drives from the drop down menu 15 Degraded drives are listed under Step 2 select a RAID group member Click on the degraded drive to rebuild The graphic changes color 16 Under Step 3 select a replacement drive select the new drive The graphic changes color 17 Click Commit 18 Inthe warning box verify that you want to rebuild the RAID group by clicking on Yes Clicking on No ends the procedure without making a change 19 When the procedure is complete the RAID Group Rebuild page appears FastStream operations add or remove Hot Spares For an explanation of Hot Spares refer to Use Hot Spares on page 11 1 Follow Preliminary steps on page 21 and click on the Manage button 2 The Manage VTL page appears Click on the FastStream drop down arrow 23 3 Select the Add Remove Hot Spares button m Select User Process amp Virtual Tape Libraries B RAID Groups Y FastStream VT AddiRemove Hot Spares C System Configuration C Set Up Error Notification ATTO Technology Inc FastStream VT 5700 Installation and O
27. NLINE 1 0GB Hot Spare 12 2 3 Optional system modifications Default values are appropriate for most configurations but may be modified for your needs using ATTO FastStream VT 5700 browser based user interface Customize the user name password It is best practice to change the default username 1 and password to a user name and password significant to you While opening a Command Line Interface CLI session is not usually recommended you must use the CLI to change the user name and password ou W DY TX Note The user name is case insensitive and password is case sensitive Change system configurations You may change several parameters using the 5 System Configuration page of the 6 ExpressNAV interface 1 Ifyou are not already in the ExpressNAV interface type the IP address of your appliance as found in Use the ExpressNAV interface on page 27 in a standard browser click Enter Here and type in your user name and password 2 The Monitor VTL page appears In the left hand menu click on the Manage button 3 Inthe main splash screen click on the FastStream menu item 4 Click on the System Configuration button Select User Process amp Virtual Tape Libraries B RAID Groups W FastStream VT 7 AddiRemove Hot Spares O System Configuration C Set Up Error Notification 13 Open a CLI session either using Telnet or the serial port as shown in Interface options on page 27 Type set Userna
28. VT 5700 and asks for the driver in the Add Hardware wizard Select Install from a list or specific location Click Next Choose Don t Search Click Next Choose Have disk The VT media changer and the VT tape have separate driver files Repeat the following steps for each driver a Specify the driver as found in the VTMediaChanger or VTTapeDrive folder in the setup CD The files are in a folder based on your operating system Win2K drivers for Windows 2000 and Windows XP Win2K3 drivers for all 2003 Server products X Note Use the files directly from the CD or copy them onto a floppy or to a local directory on your hard drive b Follow the remaining instructions to complete the installation procedure After the driver for each device is installed the tape drive is listed under Tape Drives and the VT media changer is listed under Media Changer in the System Devices folder Discover the IP address a X Note The FastStream VT 5700 is initially configured with DHCP enabled It is best if you have access to a DHCP server Work from the computer attached to the FastStream VT 5700 Ethernet port Ensure both are in the same domain From the CD supplied with your FastStream run the QuickNav Utility QuickNAV windows exe for Windows or QuickNAV Mac for Mac OS X Locate the FastStream with the serial number recorded earlier Highlight the serial number Click Next ATTO Technology Inc FastStream VT 5700 Installatio
29. appropriate application of this product shall not be the responsibility of Manufacturer Manufacturer s liability is limited to Manufacturer s product s damage to other equipment connected to Manufacturer s product s is the customer s responsibility This warranty is made in lieu of any other warranty express or implied Manufacturer disclaims any implied warranties of merchantability or fitness for a particular purpose Manufacturer s responsibility to repair or replace a defective product is the sole and exclusive remedy provided to the customer for breech of this warranty Manufacturer is not liable for any indirect special incidental or consequential damages irrespective of whether Manufacturer has advance notice of the possibility of such damages No Manufacturer dealer agent or employee is authorized to make any modification extension or addition to this warranty Contact ATTO Technology Inc Customer service sales and technical support are available by phone Monday through Friday 8 a m to 5 p m EST or by fax and website 24 hours a day ATTO Technology Inc 155 CrossPoint Parkway Amherst New York 14068 716 691 1999 voice 716 691 9353 fax www attotech com ATTO Technology can also be reached via e mail at the following addresses Sales Support sls attotech com Technical Support techsupp attotech com xxi ATTO Technology Inc FastStream VT 5700 Installation and Operation Manual xxii
30. ards European Standards Declaration of Conformity This following statement applies to the ATTO FastStream VT 5700 xix ATTO Technology Inc FastStream VT 5700 Installation and Operation Manual Application of Council Directive 89 336 EEC Standard s to which conformity is declared EN55022 CISPR 22 EN55024 CISPR24 IEC EN 60950 1 This Declaration will only be valid when this product is used in conjunction with other CE approved devices and when the entire system is tested to the applicable CE standards and found to be compliant RoH The ATTO FastStream VT 5700 complies with Directive 2002 95 EC on the COMPLIANT Restriction of the Use of Hazardous Substances in Electrical and Electronic Equipment RoHS LEAD FREE Appendix E Warranty contact information Manufacturer limited warranty Manufacturer warrants to the original purchaser of this product that it is free from defects in material and workmanship as described in the ATTO Technology website www attotech com Manufacturer liability shall be limited to replacing or repairing at its option any defective product There is no charge for parts or labor should Manufacturer determine that this product is defective Products which have been subject to abuse misuse alteration neglected or have been serviced repaired or installed by unauthorized personnel shall not be covered under this warranty provision Damage resulting from incorrect connection or an in
31. ata on the drive to be erased Make sure all of your information is backed up before setting up RAID groups RAID improves data accessibility and reliability during normal operations however you still need a good backup strategy for long term protection of your data The ATTO FastStream VT 5700 allows RAID functionality In general the process begins with individual drives also called block devices x Note Ifa drive has corrupt or outdated configuration data that drive cannot be assigned to any RAID group Ensure all drives to be assigned to RAID groups are configured properly Refer to Initialize and verify drives on page 19 and Clean RAID configuration information on page 25 A RAID group is a virtual independent single drive whose data is written to physical drives according to a RAID algorithm The ATTO FastStream VT 5700 supports JBOD RAID Level 0 RAID Level 1 RAID Level 10 and RAID Level 5 JBOD Just a Bunch of Disks JBOD Just a Bunch of Disks configuration allows many individual drives to be available for normal storage operations with no special data protection Using the ATTO FastStream VT 5700 allows you to concatenate several individual drives into one large drive A JBOD drive can be constructed as a special case of a RAID group When multiple physical drives are assigned toa JBOD RAID group their storage areas appear as a single spanned area of storage The ATTO FastStream VT 5700 supports 1 to
32. data for the FC port you specify Data includes the average rate MB per sec and number of I Os measured over the previous sampling period where a sampling period is approximately one second Successful SCSI Read 08h 28h and Write Oah 2Ah commands are considered I Os Reported performance may be affected by FC port and bus availability and saturation device speeds and overall system use get Performance lt fp gt Ping Sends an ICMP echo request to the specified host ping mp1 xxx xxx xxx xxx lt count lt size gt gt RAIDCommandTimeout Specifies in milliseconds the range of time the drives have to respond You must use RGCommit before using this command A CAUTION If you set this value too low failures may occur during normal operation Default 30000 set RAIDCommandTimeout 100 3600000 Requires a SaveConfiguration Restart command get RAIDCommandTimeout RAIDRebuildPriority Sets or displays the RAID rebuild priority A RAID rebuild priority set to high gives higher priority to RAID rebuilds and lower priority to the processing of simultaneous I O transactions A RAID rebuild priority set to low gives lower priority to the rebuild and a higher priority to I O transactions Set same the RAID rebuild and processing of I O transactions is the same Default same set RAIDRebuildPriority high low same Requires a SaveConfiguration command get RAIDRebuildPriority Reserve Reports the state of CLI reser
33. drives to the FastStream perform drive initialization and verification to ensure the integrity of these drives refer to Initialize and verify drives on page 7 A CAUTION Clicking on Commit during RAID configuration causes all previous storage data on the drive to be erased Ensure all data is backed up as found in Use the ExpressNAV interface on page 27 in a standard browser click Enter Here and type in your user name and password 2 The Monitor VTL page appears 3 Click on the appropriate button on the left hand side of the ExpressNAV interface 4 Select the operation you wish to perform from the next menu presented 4 Follow the instructions in Use custom setup on page 10 Delete a Virtual Tape Library 1 Follow Preliminary steps above and click on the Manage button 2 The Manage VTL page appears Choose the Virtual Tape Libraries arrow 3 Click in the Delete Virtual Tape Library button 4 Click on Next 5 Click on radio box displaying the name of library 6 Click Commit 7 Inthe warning box verify that you want to delete the VTL by clicking on Yes Clicking on No ends the procedure without making a change 8 After the process completes the VTL Monitor page appears ATTO Technology Inc FastStream VT 5700 Installation and Operation Manual Secure data through Write Protection For added security write protection can be enabled for any tape cartridge with a VTL When write protection is enabled existin
34. e g1 span commit RGCancelAddStorage rgcanceladdstorage g1 RGCommit rgcommit all RGCreate rgcreate g1 raid0 RGDelete rgdelete g1 vii ATTO Technology Inc FastStream VT 5700 Installation and Operation Manual Command Default Example RGDisplay rgdisplay all RGHaltConversion rghaltconversion g1 RGHaltRebuild rghaltrebuild g1 RGMemberAdd rgmemberadd g1 22 RGMemberRemove rgmemberremove g1 22 RGRebuild rgrebuild g1 RGResumeConversion rgresumeconversion g1 RGResumeRebuild rgresumerebuild g1 RGSpanDepth 1 set rgspandepth g1 22 RGSpeedRead disabled set rgspeedread g1 enabled RGWaitTimeout 5 set rgwaittimeout 30 RMState set rmstate g1 online RMStatus rmstatus g1 Route route fc 0 raid alpha1 6 RouteDisplay routedisplay fc SaveConfiguration saveconfiguration restart SerialNumber get serialnumber SerialPortBaudRate 115200 set serialportbaudrate 19200 SerialPortEcho enabled get seriallportecho SNTP enabled get sntp SNTPServer 192 43 244 18 set sntpserver 129 6 15 28 TailEventLog taileventlog TapeLibDelete tapelibdelete barb2 TapeLibInfo tapelibinfo barb1 TapeWriteProtect disabled tapewriteprotect all enabled Temperature get temperature Time set time 03 32 30 TimeZone EST set timezone pst Username root set username Barbara VerboseMode enabled set verbosemode disabled Voltage get voltage VTLCapInf
35. e same Ethernet network 2 Starta Telnet session TX Note There is more than one way to connect to the FastStream VT 5700 using a telnet program Your telnet program may operate differently than in the following instructions e Echo off f Click OK 4 After you connect to the FastStream VT 5700 start up messages are displayed The last line in the start up message sequence is Ready Make adjustments to the FastStream VT 5700 using the Command Line Interface as described in CLI provides an ASCll based interface on page v of the Appendix AK Note In serial port sessions there is no prompt on the line below the word Ready Begin typing commands in the blank line where the cursor is resting No user name or password is required for serial port access 5 Toverify that you have connected successfully type help after the Ready prompt and press Enter Ifa list of all available commands does not appear on the screen review the steps in this section check the cable or contact service personnel until the problem is solved If you have difficulty using the serial port verify that you have the correct settings and that your serial cable is less then two meters long 3 Atthe telnet prompt issue the open command where x x x x is the IP address of the FastStream VT 5700 telnet gt open x x x x 4 Ifyou have to specify a port type type in the port type telnet and the terminal type vt100 port type telnet
36. e status of all RAID members within the specified RAID group or a specific RAID member if specified within a RAID group RMStatus GroupName lt Member Index gt Route Assigns a host protocol address to a target destination device More than one FC LUN may be assigned to a partition If you try to map a new partition to the same FC LUN the previous map is overwritten Use the Delete identifier to remove the map In verbose mode overwriting a map requires secondary confirmation of the action Route FC fp lun RAID GroupName Partition Index Bridge Delete RouteDisplay Displays a combined list of host protocol address to target destination device mappings RouteDisplay FC lt fp gt lt lun gt SaveConfiguration Issued with the restart option cycles unit power after saving configuration changes The norestart option saves changes without restarting Ue Note Certain modifications require a system restart SaveConfiguration lt Restart NoRestart gt SerialNumber Reports the FastStream serial number which is unique for each FastStream The serial number tracks the board throughout its life and should not be changed get SerialNumber SerialPortBaudRate Configures the baud rate for the units RS 232 serial port The number of data bits is fixed at 8 with no parity Default 115200 set SerialPortBaudRate 9600 19200 38400 57600 115200 Requires a SaveConfiguration Restart command get
37. eTestList drive BlockDevID all get DriveTestList DriveTestStatus Displays the status of the currently running drive test but does not display performance metrics If a block device ID is not running or cannot be found its state is idle and percent complete is 0 get DriveTestStatus lt drive BlockDevID gt DumpConfiguration Displays the units configuration to a current CLI session DumpConfiguration DumpEventLog Displays the contents of the entire event log to the current CLI session without impact on the log itself the log is not cleared No events are recorded until the command has been completed DumpEventLog EmailFromAddress Configures the E mail address that the FastStream uses to talk to the E mail server Full E mail address is a fully qualified Internet E mail address with no more than 128 characters set EmailFromAddress full email address get EmailFromAddress EmailNotify Regulates E mail notification Default disabled set EmailNotify enabled disabled Requires a SaveConfiguration command get EmailNotify EmailNotifyAddress Configures notification addresses using an index a number between 1 and 5 inclusive the full E mail address of the recipient a fully qualified Internet E mail address not more than 128 characters long and a level Levels are None no E mails sent Critical critical event notification Warning warnings and critical event notification Informational inf
38. ed drive add new drives or redesign VTL configurations The ExpressNAV interface takes you step by step through many procedures which allow you to modify your storage and VTL Read all notes and cautions carefully as you go to ensure the best performance and use of your storage Be cautious when deleting storage or rearranging storage configurations because data could be compromised or lost Many of these procedures are only available when using unallocated drives or storage Preliminary steps XK Note An unallocated drive or unallocated storage is storage which is not part of a RAID group not designated as a Hot Spare or was offline when you initially set up a RAID configuration using the ExpressNAV interface 1 If you are not already in the ExpressNAV interface type the IP address of your appliance Virtual Tape Library operations You may add to delete or change the VTLs in your configuration using the ExpressNAV interface Select User Process W Virtual Tape Libraries C Create Virtual Tape Library Delete Virtual Tape Library Enable Disable Write Protection C Move Medium B RAID Groups B FastStream VT Create a Virtual Tape Library 1 Follow Preliminary steps above and click on the Manage button 2 The Manage VTL page appears Choose the Virtual Tape Libraries arrow 3 Click on Create a Virtual Tape Library 21 When you initially set up the FastStream replace a failed drive or add new
39. eeeenees xix FCC Standards Radio and Television Interference MET Canadian Standards European Standards Appendix E Warranty contact information ssseeseeeeeeeeeeees xxi Manufacturer limited warranty Contact ATTO Technology Inc 1 0 ATTO FastStream VT 5700 increases reliability The ATTO FastStream Virtual Tape 5700 Appliance is a mid range storage solution that emulates a tape library for fast backups on demand and error free restores of critical data The ATTO FastStream Virtual Tape 5700 is seen by system applications as a conventional tape library allowing you to use existing disk based storage as if it were tape The ATTO FastStream VT 5700 delivers immediate performance improvements to backup restore and archive applications Adding a disk based Virtual Tape Library VTL ensures high speed access to your data The FastStream VT can be seamlessly integrated into existing storage environments as if it were a traditional tape library The ATTO FastStream VT 5700 also provides high performance RAID parity protection to existing disk based storage without regard to manufacturer type of drive capacity or speed Adding RAID ensures your data is protected without compromising performance However RAID is not a replacement for regular backups A good backup strategy is still the best long term investment in your data The ATTO FastStream VT 5700 is available in 1U desktop and industry standard rack m
40. en the existing RAID group is in the process of having storage added If the init option is specified previous user configuration information is erased from each new member drive RGCommit lt GroupName lt init gt all lt init gt gt RGCreate Creates a new empty RAID group The optional value after the RAID group type parameter represents the desired interleave for the RAID group If this value is not provided then the system default interleave size is used RGCreate GroupName RAID 0 1 10 5 JBOD lt 16 32 64 128 256 512 1024 2048 gt RGDelete Deletes the specified RAID group If All is used the command deletes all existing RAID groups that do not have mapped Virtual drives Any commands outstanding to the RAID group when this command is issued are completed before deleting the RAID group A successful delete clears the configuration area of the member drives If you have enabled verbose mode you are asked to confirm the delete RGDelete GroupName All RGDisplay Displays status information for a single RAID group or if All is used all available RAID groups RGDisplay lt GroupName All gt RGHaltConversion Stops the conversion on the specified existing RAID group RGHaltConversion GroupName RGHaltRebuild Stops the rebuild s on the specified existing RAID group Ifno Member Index is specified all rebuilds on that RAID group are stopped RGHaltRebuild GroupName lt Me
41. ent For set commands the final parameter indicates whether or not events from the specified subsystem and level is displayed Default all all all set DisplayEventLogFilter subsystem all level all all none Requires a SaveConfiguration command get DisplayEventLogFilter subsystem all level all DriveTest Starts or stops a drive test with a previously specified configuration and drive list refer to DriveTestConfig and DriveTestList Drives which are in use by the test are not available for RAID configuration or RAID operations Only one test can be run at a time Drives to be tested cannot be part of a RAID group or in use as Hot Spares DriveTest Begin Cancel DriveTestConfig Configures the next drive test to perform one of the following operations initialize destructive write only read non destructive read only verify destructive verify or init verify destructive write read verify The test is not started until the DriveTest Begin command is given Drives to be tested cannot be part of a RAID group or in use as Hot Spares Default not initiated set DriveTestConfig init read verify init verify get DriveTestConfig DriveTestList Specifies drives to be run in the next drive test of drives which are not part of a RAID group or which are Hot Spares The all parameter automatically chooses eligible drives The test is not started until the DriveTest Begin command is given set Driv
42. erformance Cable length Cable size Up to 175 meters 62 5 micron Up to 500 meters 50 micron Ports and 2 connect to the host ports 3 and 4 connect to devices Refer to Exhibit 1 1 1 Ethernet port A 10 100 Ethernet standard RJ45 management port provides monitoring and management Serial port The RS 232 serial port provides ilo support for remote monitoring and RX 2 a 4 management using a DB9 connector me 8 The baud rate is programmable and enps l gg 9 preset at the factory to 115200 bps Reset restore factory default switch To reset the FastStream briefly insert a tool in the hole in the back panel To restore factory defaults insert the tool in the hole in the back panel for more than four seconds until the green Ready LED blinks ATTO Technology Inc FastStream VT 5700 Installation and Operation Manual LED indicators The LED indicators can be viewed from the back or the front side of the FastStream VT 5700 LEDs on the connector side see Exhibit 1 1 1 are A bicolor Ready Fault LED lights green to indicate ready lights yellow to show a faulted condition and is off to indicate not ready Embedded in the Ethernet port connector a lighted green LED shows a valid link off indicates that no link is present A separate blinking yellow LED indicates activity Fibre Channel port A lighted green LED indicates link off means no link A separate green LED indicates activity if it is lit n
43. g data on the tape cartridge cannot be overwritten or erased The displayed data can be sorted by any field by clicking on the heading for the field clicking twice reverses the sort order 1 Follow Preliminary steps on page 21 and click on the Manage button 2 The Manage VTL page appears Choose the Virtual Tape Libraries arrow 3 Click in the Enable Disable Write Protection button 4 Click on Next 5 Click on the tab with the name of the VTL for which you wish to change write protection 6 Click in the radio box next to the element you wish to change 7 Click Commit 8 A waring box appears If you wish to proceed click on Yes Clicking on No ends the procedure without making a change RAID group procedures You may change the RAID groups underlying your VTLs using the ExpressNAV interface Select User Process B Virtual Tape Libraries W RAID Groups Add Drives to an Existing RAID Group C Rebuild RAID Groups B FastStream YT Increase the size of a VTL If you have unallocated drives you can increase the number of drives used by an existing VTL by adding an unallocated drive to the VTL RAID group The increased capacity of the RAID group becomes additional Virtual Tape cartridges in the library You may have to add more than one drive 9 The Enable Disable Write Protection page appears If you wish to protect other elements or elements in another library select the library and repeat this procedure
44. he flow of data The firmware to control these processors can be upgraded in the field using the PUT command from an FTP connection or the zModem utility over an RS 232 serial connection A CAUTION Ensure that all I O to the ATTO FastStream VT has stopped 25 3 Click the Clean RAID Configuration Data button m Select User Process O Initialize and Verify Drives O Read Only Drive Test O Drive Performance and Health O Identify Drive Clean RAID Configuration Data 4 Click Next 5 Click on the drive you wish to process the drive is highlighted 6 Click Commit 7 A warning message displays choose yes to continue 8 The Health and Status Monitor screen appears XK Note To clean Hot Spare information from a drive use the Add Delete Hot Spares feature to delete the Hot Spare Refer to Use Hot Spares on page 11 A CAUTION During this procedure do not interrupt the flash process Do not power down the host or the ATTO FastStream VT until the display returns the Ready prompt Interrupting the flash process makes your ATTO FastStream VT inoperable and you must return it to ATTO for repair ATTO Technology Inc FastStream VT 5700 Installation and Operation Manual Preliminary steps 1 The ATTO FastStream VT firmware is distributed as a compressed zip file Uncompress the zip file into an image file ima Note the filename The zip file can be uncompressed using any utility that supports the zip format
45. he table A CAUTION Do not use CLI unless you are directed to by an ATTO technician Changing parameters may cause loss of data and or disruption to performance and reliability of the FastStream The ExpressNAV interface is the preferred method to operate and manage the FastStream VT 5700 Refer to Interface options on page 27 for details Command Default Example AutoMap automap AutoResume enabled set autoresume all disabled BlockDevClean blockdevclean 3 BlockDevldentify blockdevidentify 1 BlockDevIDStop blockdevidstop BlockDevScan blockdevscan BridgeModel get bridgemodel BridgeName a set bridgename Omega6 ClearEventLog cleareventlog Date set date 03 03 2003 DefaultInterleave 128 set defaultinterleave 64 DeleteAllMaps deleteallmaps DHCPFixedDelay 0 set dhcpfixeddelay 15 DisplayEventLog displayeventlog DisplayEventLogFilter all all all set displayeventlogfilter gen info all DriveTest drivetest begin DriveTestConfig set drivetestconfig read DriveTestList set drivetestlist all DriveTestStatus get driveteststatus DumpConfiguration dumpconfiguration DumpEventLog dumpeventlog EmailFromAddress set emailfromaddress notify1 attotech com vi Command Default Example EmailNotify disabled set emailnotify enabled EmailNotifyAddress get emai
46. ick Configuration Select User Process O initialize and Verify Drives O System Configuration Quick Configuration O Custom Setup The FastStream scans your system for drives the Quick Configuration page appears displaying the number of drives discovered and the total capacity of those drives 3 Type in a name for your Virtual Tape Library Names may be up to 14 characters and may not contain any spaces 4 Answer the questions in Step 2 based on the needs of your software vendor e If your storage is RAID protected the FastStream does not reconfigure it If it is not the FastStream sets the RAID level e Select the number of simultaneous backups you wish to run from 1 to 30 e Click in the box if you want a Hot Spare refer to Use Hot Spares on page 11 The FastStream rescans the system to recalculate capacity Select Next The VTL Setup Summary page appears If the configuration is the way you want it click Commit A warning box appears T A Note Clicking on Cancel takes you to the Monitor VTL screen You can choose to begin this procedure again by following the directions in Step 4 of Use custom setup on page 10 or to get back to the Quick Initial Configuration page exit out of ExpressNAV and restart the process at Step 1 of the Use quick initial configuration procedure In the warning box verify that you want to add the VTL by clicking on Yes x Note Clicking on No returns you to the Virt
47. ld s on the specified existing RAID group If no Member Index is specified all stopped rebuilds on that RAID group are continued RGResumeRebuild GroupName lt Member Index gt RGSpanDepth Sets the span depth on the specified existing RAID group The RAID group must be RAID Level 0 RAID Level 1 RAID Level 5 or RAID Level 10 Default 1 set RGSpanDepth GroupName Span Depth 1 32 get RGSpanDepth GroupName ATTO Technology Inc FastStream VT 5700 Installation and Operation Manual RGSpeedRead Performs look ahead during reads from RAID group member disks for all or the specified RAID group Default all disabled set RGSpeedRead GroupName all enabled disabled get RGSpeedRead GroupName all RGWaitTimeout Specifies the maximum time in seconds that the system waits to discover previously configured RAID groups attached to the drive The timeout is used during system boot time and when the BlockDevScan command is issued Default 5 set RGWaitTimeout 1 3600 Requires a SaveConfiguration Restart command get RGWaitTimeout RMState Regulates the state on the specified existing RAID group member s Ifno Member Index is specified the status of all members of the specified RAID group is set XK Note Members undergoing rebuild are not changed Rebuilds on these members must first be stopped set RMState GroupName lt Member Index gt Online Degraded Unavailable Faulted RMStatus Displays th
48. lnotifyaddress EmailPassword set emailpassword alpha123 EmailServerAddress 0 0 0 0 get emailserveraddress EmailUsername get emailusername EthernetSpeed auto set ethernetspeed 100 EventLog enabled set eventlog disabled EventLogFilter all all all set eventlogfilter gen info none Exit exit FCConnMode loop set feconnmode all ptp FCDataRate auto get fcdatarate FCHard disabled set fchard disabled FCHardAddress fp1 3 fp2 4 fp3 5 fp4 6 set fchardaddress 1 122 FCMultiNode enabled set femultinode disabled FCPortErrors get fcporterrors all FCPortList fcportlist FCTargets fctargets FCWWName get fewwname 1 FirmwareRestart firmwarerestart Help help driveinfo HSAdd hsadd 3 HSDisplay hsdisplay HSRemove hsremove 3 IdentifyBridge disabled set identifyBridge enabled Info info IPAddress get ipaddress mp1 IPDHCP enabled set ipdhcp mp1 disabled IPGateway get ipgateway mp1 IPSubnetMask get ipsubnetmask mp1 IsReserved isreserved MaxOpTemp 70 get maxoptemp Metrics metrics display all MinOpTemp 0 set minoptemp 10 OpTempWarn 5 set optempwarn 15 PartitionDisplay partitiondisplay alpha1 Password Password set password Performance get performance 2 Ping ping mp1 192 42 155 155 RAIDCommandTimeout 30000 set raidcommandtimeout 10000 RAIDRebuildPriority same set raidrebuildpriority low Reserve reserve ResetFCPortErrors resetfcporterrors 1 RestoreConfiguration restoreconfiguration default RGAddStorage rgaddstorag
49. mber Index gt XV RGMemberAdd Adds up to 10 available block devices to a new RAID group This command fails if the specified RAID group does not exist if the specified RAID group is not in the new state or if the specified block device index does not represent an available device If all is specified then all available block devices are added to the RAID group until the maximum number of RAID group members has been met The command resets the number of RAID group partitions to 1 RGMemberAdd GroupName all BlockDevID RGMemberRemove Removes a RAID member from a new RAID group This command fails if the specified RAID group does not exist if the specified RAID group is not in the new state or if the specified block device index does not represent an available device The command resets the number of RAID group partitions to 1 RGMemberRemove GroupName BlockDevID RGRebuild Starts rebuilding the specified existing RAID group Optional parameter Member Index specifies the member to rebuild If no member is specified all degraded members are rebuilt Optional parameter BlockDevID allows an available block device to be substituted for the RAID member currently assigned to the Member Index RGRebuild GroupName lt Member Index gt lt BlockDevID gt RGResumeConversion Continues the stopped conversion on the specified existing RAID group RGResumeConversion GroupName RGResumeRebuild Continues the rebui
50. me user name Press Enter Type set Password Press Enter Follow the instructions on the screen to confirm your old and new password The user name and password for all Telnet FTP and ATTO FastStream VT 5700 browser based user interface sessions is changed Click on Next Click on the choices available A choice may be greyed out because it is not available based on a previous choice Appliance name you may wish to give this FastStream VT a name which is significant to you if you are managing several ATTO devices from a single workstation Time and Date Refer to Time and TimeZone on page xvii and Date on page ix of the Appendix Fibre Channel data rate and connection mode for each Fibre Channel port Refer to FCDataRate on page xii and FCConnMode on page xi of the Appendix Enable or disable hard address assignment refer to FCHard on page xii of the Appendix When you have completed your changes click on Commit ATTO Technology Inc FastStream VT 5700 Installation and Operation Manual Customize other parameters using the Advanced CLI page Changes to other parameters may be made using the Advanced page A CAUTION Do not use this page unless you are directed to by an ATTO technician Changing parameters may cause loss of data and or disruption to performance and reliability of the FastStream TY Note S The ExpressNAV interface is the preferred method to manage the FastStream 1 If you are not al
51. n Submit The FastStream discovers the VTL from the other FastStream In the text box provided type AutoMap Click on Submit When Ready is displayed in the screen below type SaveConfiguration Click on Submit Click on the VTL menu item on the left hand side of the screen The Monitor VTL page appears A tab for the library you just added is displayed 24 5 0 Update storage and firmware You can update the ATTO FastStream VT at any time Refer to www attotech com for complete information Several methods are available to update the ATTO FastStream firmware and to re initialize unattached storage Be sure all data is backed up before using any of these procedures to prevent data loss Clean RAID configuration information This feature only works with drives that belong to RAID groups and drives that had once been part of a RAID Group and are now flagged Replaced A CAUTION Data is erased during this process Back up your data before selecting Commit These operations have a negative impact on the performance of normal operations all activity should be stopped 1 If you are not already in the ExpressNAV interface type the IP address of your appliance as found in Use the ExpressNAV interface on page 27 in a standard browser click Enter Here and type in your user name and password 2 Click the Diagnostics button Update firmware The ATTO FastStream VT has several processors which control t
52. n and Operation Manual If a DHCP server is available on your network an address is assigned automatically by the server Note the assigned address If you do not have a DHCP server get an IPaddress and subnet mask from your network administrator type it into the area provided and select Next Click on Launch Browser Your browser points to the FastStream VT 5700 splash screen If you use Internet Explorer as a browser continue on to Internet Explorer setup below If not continue on to Begin initial configuration Internet Explorer setup 1 2 3 4 5 6 7 8 9 Open your browser Select Internet Options In the Internet Options screen select the Security tab Click on the Trusted Sites icon Click on the Sites button In the text box Add this Web site to the zone add the IP address of the appliance You may use wild cards Click on Add Uncheck the Require server verification check box Click OK 10 Atthebottomofthe Internet Options box click on OK and close the box Exhibit 2 0 1 General bracket assembly FastStream front bracket supplied by ATTO Rack aC screws supplied by ATTO Begin initial configuration 1 The ExpressNAV interface welcome screen appears Click on Enter Here 2 Type in the user name and password g x Note The default user name is root it is case insensitive The default password is Password it is case sensitive It is best practice to change the passw
53. n each drive to see its information highlighted in the Drive Metrics window 1 Follow the instructions in Preliminary steps on page 19 2 Click on Drive Performance and Health Select User Process O Initialize and Verify Drives O Read Only Drive Test Drive Performance and Health O Identify Drive Clean RAID Configuration Data 3 Click Next 4 The Drive Performance and Health page appears Click on a drive in the drive section 5 Click Start 6 Drive performance is displayed under the Drive Metrics section of the Drive Performance and Health page Drive errors are displayed in the Drive Errors section of the page Identify a drive attached to the FastStream A CAUTION Executing this command adversely impacts performance and throughput for the time that the LED is illuminated 1 Follow the instructions in Preliminary steps on page 19 2 Click on Identify Drive Select User Process O initialize and Verify Drives O Read Only Drive Test O Drive Performance and Health Identify Drive O Clean RAID Configuration Data 3 The Identify Drive page appears Click on any drive Only one drive may be selected at a time 4 Click Commit The I O LED of the drive illuminates for one minute 5 To stop the operation unselect the drive x Note To clean RAID configuration data refer to Clean RAID configuration information on page 25 20 4 0 Modify storage Use the ExpressNAV interface to replace a fail
54. name for your FastStream 3 0 Monitor storage configurations iiinn 15 Monitor VTL page Health and Status Monitor page Configuration Display page Phone home E mail messages Identify drive issues Preliminary steps Initialize and verify drives Scan drive surfaces read only drive test Measure drive performance and health Identify a drive attached to the FastStream 4 0 Modify storage elle 21 Preliminary steps Virtual Tape Library operations Create a Virtual Tape Library Delete a Virtual Tape Library Secure data through Write Protection Move Virtual Tape cartridges RAID group procedures Increase the size of a VTL Rebuild RAID groups FastStream operations add or remove Hot Spares Add a VTL from another FastStream VT 5 0 Update storage and firmware r 25 Clean RAID configuration information Update firmware Preliminary steps Use FTP over Ethernet Use the RS 232 serial link 6 0 Interface options alora 27 Use the ExpressNAV interface Use the serial port Use Telnet Appendix A Glossary i uniiiiia ein i Appendix B Designing RAID groups rrr ili JBOD Just a Bunch of Disks RAID Level 0 RAID Level 1 RAID Level 10 RAID Level 5 Appendix C CLI provides an ASCll based interface v CLI error messages CLI summary CLI command explanations Appendix D Standards and compliances ccccccesssseeeeeeeeeneee
55. ng Error Correcting Checksum ECC and Parity checks on all data paths Potential corruption cannot go undetected Phone Home error notification automatically generates an E mail alert in the event of a failure Drive initialization and verification identifies attached drives which exhibit poor performance or soft failures Capable of measuring performance during normal operation and during the drive initialization process ATTO Technology Inc FastStream VT 5700 Installation and Operation Manual 5 Ethernet e a Possible storage Fibre Channel sa es configurations SCSI GbE network g ATTO iPBridge 2700 ATTO Celerity FC a Fs storage adapter I 4 Gb LA N GbE Switch a FastStream M 5700 embedded ATTO iPBridge 1500 1550 2500 JBOD SCSI Tape Library SCSI model SCSI Tape Library ATTO Diamond Storage Array 2 Introduction 1 1 Physical attributes The ATTO FastStream VT 5700 is a Fibre Channel to Fibre Channel storage appliance which can be seamlessly integrated into an existing storage environment The ATTO FastStream VT 5700 is available in an industry standard 1U form factor for easy integration into industry standard racks It supports next generation media and as a result is equipped to handle the throughputs needed by advanced disk technologies Dimensions Width 17 inches Length 8 94 inches Height 1 7 inches 1U Weight approximately 8 pounds Cooling
56. o activity if it is off LEDs on the front see Exhibit 1 1 2 are A green power LED A bicolor Ready Fault LED is lighted green to indicate ready lighted yellow to show a faulted condition and off indicates not ready Fibre Channel ports bicolor LED indicates FC speed If it is off speed is 1 Gb if itis green 2 Gb and yellow indicates 4 Gb FC A separate green LED indicates activity if it is lit no activity if it is off Exhibit 1 1 1 The connector side of the FastStream VT 5700 SNES SEO SE SS P E Channel Host je fd Reset O Ethernet Port Port 1 Exhibit 1 1 2 The faceplate of the FastStream VT 5700 An FasT STREAM Fibre Channel Host Port 1 1 2 Activity Activity O LinkO Port 2 Channel Device se O LinkO Port 3 Port 4 Fibre Channel Device Port 3 Port 4 1 2 1 2 Activity Activity Port 2 12 Activity 2 0 Installation Ifyou have not already completed the instructions on the Quick Start page packed with your FastStream VT 5700 use the following instructions to install the FastStream VT 5700 Unpack the packing box verify contents The FastStream Note the serial number of your FastStream unit Power cord L brackets for mounting in a 19 rack CD which includes the Firmware Installation and Operation Manual QuickNAV IP discovery program and system drivers Install the FastStream 1 5 Place the FastStream VT 570
57. oNotify 75 set vtlcapinfonotify 70 VTLCapWarnNotify 90 set vtlcapwarnnotify 80 WrapEventLog enabled set wrapeventlog disabled zModem zmodem receive viii CLI command explanations Command Line Interface commands are listed alphabetically with explanations of what they are used for their defaults and syntax A CAUTION Using CLI without contacting an ATTO technician is not recommended because changing parameters may cause loss of data and or disruption to performance and reliability of the FastStream The ExpressNAV interface is the preferred method to operate and manage the FastStream VT 5700 Refer to Interface options on page 27 for details AutoMap Automap automatically maps a subset of target devices visible to the firmware All previous maps are deleted If ECMultiNode is enabled AutoMap fp SaveConfiguration command required If FCMultiNode is disabled AutoMap AutoResume Regulates the automatic continue feature for interrupted operations at startup If enabled all interrupted operations are continued at startup If no GroupName is specified all existing RAID groups are affected Default all enabled set AutoResume Rebuild all enabled disabled lt GroupName gt BlockDevClean Removes any ATTO configuration data from the block device with the specified BlockDevID BlockDevClean BlockDevID WARNING All RAID group setup information and RAID group data is lost if you use the BlockDevClean
58. ommercial environment Operation of this equipment in a residential area is likely to cause interference in which case the user at his own expense will be required to take whatever measures may be required to correct the interference If this equipment does cause interference to radio and television reception which can be determined by turning the equipment off and on try to correct the interference by one or more of the following measures e Move the receiving antenna If necessary consult an ATTO authorized e Relocate the FastStream VT 5700 with respect dealer ATTO Technical Support Staff or an to the receiver or move the FastStream VT experienced radio television technician for 5700 away from the receiver additional suggestions e Plug the computer into a different outlet so the computer and receiver are on different branch circuits The booklet How to Identify and Resolve Radio TV Interference Problems prepared by the Federal Communications Commission is a helpful guide It is available from the US Government printing office Washington DC 20402 Stock No 004 000 00345 4 MET Listed with MET UL 60950 1 CSA C22 2 No 60950 1 Canadian Standards Da This Class A digital apparatus complies with Canadian ICES 003 Cet appareil num rique de la classe A est conforme la norme NMB 003 du Canada This device has been tested in the basic operating configuration and found to be compliant with the following European Union stand
59. ords Refer to Optional system modifications on page 13 3 The Initial Setup page appears Select User Process Initialize and Verify Drives O System Configuration O Quick Configuration O Custom Setup Before creating a Virtual Tape Library you may wish to initialize and verify your drives to ensure drive integrity Refer to Initialize and verify drives on page 7 A CAUTION Selecting Drive Initialization causes all previous storage data on the drive to be erased Make sure all of your information is backed up before initializing drives 4 Goon to Configure Virtual Tape on page 7 flat washers supplied by customer 2 lock washers 27 supplied by customer 10 32 pan head screws supplied by customer 2 1 Configure Virtual Tape The ATTO FastStream VT allows configuration of storage into one or two JBOD RAID Level 0 RAID Level 1 RAID Level 10 or RAID Level 5 Virtual Tape Libraries VTL The FastStream VT appears to hosts as a tape library allowing ISV packages to issue a set of tape library commands to perform backup and restore operations to the FastStream The FastStream VT configures your storage into one or two Virtual Tape Libraries VTL depending on the choices you make For every Virtual Tape Library created on the FastStream VT an underlying RAID Group is created from the selected drives to provide the physical storage medium for the Virtual Tape cartridges You may either u
60. ormation notification All all warnings critical events informational notices set EmailNotifyAddress index full email address warning level get EMailNotifyAddress EmailPassword Configures the password used to authenticate the login to the SMTP E mail server The password must not be more than 64 characters A password is not required if the E mail server does not require authentication set EmailPassword Requires a SaveConfiguration command EmailServerAddress Configures the address of the server that the FastStream should contact in order to send E mails Default 0 0 0 0 set EmailServerAddress IP address Requires a SaveConfiguration command get EmailServerAddress xi EmailUsername Configures the user name used to authenticate the login to the SMTP E mail server The user name must not be more than 128 characters A user name is not required if the E mail server does not require authentication set EmailUsername user name Requires a SaveConfiguration command get EmailUsername EthernetSpeed Sets displays the current speed of the Ethernet connection Choices are 10 100 and Auto Default auto set EthernetSpeed mp1 10 100 Auto Requires a SaveConfiguration Restart command get EthernetSpeed mp1 EventLog When enabled records various system errors to the event log Default enabled set EventLog enabled disabled get EventLog EventLogFilter Filters data from specific unit subsy
61. ount enclosures Hardware features 4 independent 4 Gigabit Fibre Channel interfaces to integrate existing direct attached storage into a high performance SAN environment e O S and platform independent 64 bit OS supported e RoHS compliant Virtual Tape features e Seen by ISV applications as a conventional tape library e Configure one or two Virtual Tape libraries VTL 1 Configure up to 30 Virtual Tape drives and 256 Virtual tapes for each library Hardware RAID Level 0 RAID Level 1 RAID Level 5 RAID Level 10 and JBOD all user configurable Backup and restore features Performs up to 30 concurrent backups for each Virtual Tape Library Backup and restore data at up to 1 89 TB per hour Uses reliable disk storage to take the place of conventional tape to deliver immediate performance improvements to backup and restore applications Management and control features The ATTO ExpressNAV interface a browser based GUI simplifies configuration management and navigation Field updateable firmware with the ability to save configuration settings for easy field replacement Automatic rebuild of RAID groups and Rebuild Priority keeps the system operational if a drive fails Global Hot Spares ensure continuous operation if a drive fails The Hot Spare automatically comes on line and rebuild starts if a disk failure is detected ECC Protected Memory assures data integrity and continued up time by implementi
62. peration Manual 4 Click Next 5 Select the drive s you want to add or remove from the Hot Spare pool 6 When you have completed your changes click Commit 7 In the warning box verify that you want to add or remove the Hot Spare by clicking on Yes Clicking on No ends the procedure without making a change When the process is complete the Health and Status Monitor page appears To use the System Configuration button refer to Change system configurations on page 13 To use the Set Up Error Notification button refer to The E mail messages sent by the FastStream VT 5700 follow this format on page 18 Add a VTL from another FastStream VT You may attach a VTL from another FastStream VT to the FastStream VT you are currently working with The current FastStream VT must discover the other VTL through mapping When you create your first library the media changer and tape drive LUNs are mapped automatically to one of two ports When you recognize a second library it may be mapped to the other port or to the same port TX Note The FastStream VT supports two libraries one on each port or both on one port 1 If you are not already in the ExpressNAV interface type the IP address of your appliance as found in Use the ExpressNAV interface on page 27 in a standard browser click Enter 10 Here and type in your user name and password Click on the Advanced button In the text box provided type blockdevscan Click o
63. ready in the ExpressNAV interface type the IP address of your appliance as found in Use the ExpressNAV interface on page 27 in a standard browser click Enter Here and type in your user name and password 2 The Monitor VTL page appears In the left hand menu click on the Advanced menu item on the left side of the screen 3 The Advanced CLI Configuration page appears Wait for the Ready prompt then type in the CLI command in the text box provided Refer to CLI provides an ASCll based interface on page v of the Appendix 4 Click the Submit button this is equivalent to typing in the CLI command into a telnet or serial port CLI session A text field beneath the box lists the most recent commands issued to the FastStream through this page If you enter an incorrect parameter the CLI help text is displayed showing the parameters available An asterisk next to the Ready prompt indicates you must type SaveConfiguration restart in the text box for changes to take effect Discover manage other ATTO devices If you have other ATTO devices in the same broadcast domain with no routers between them and any switches between this FastStream VT and the other devices are configured to forward UDP broadcast messages you may physically identify these devices and manage them from within the browser you are currently using 1 If you are not already in the ExpressNAV interface type the IP address of your appliance as found in Use the E
64. referred method to operate and manage the FastStream VT 5700 However it may be necessary to use other methods to access the FastStream VT 5700 such as to change the user name and password refer to Customize the user name password on page 13 Use the ExpressNAV interface Use the ExpressNAV interface to manage monitor and configure the unit The choices you make lead you from screen to screen Choices which are not available are greyed out 1 Working from the computer attached to the FastStream VT 5700 Ethernet port open your browser and type in the FastStream VT 5700 IP address as noted in Discover the IP address on page 5 2 Your browser points to the ExpressNAV interface splash screen Press Enter 3 Type in the user name and password values ATTO Technology Inc 2002 2006 ATTO Technology Inc 27 A CAUTION Changing parameters other than those offered in the ExpressNAV interface may cause loss of data and or disruption to performance and reliability of the FastStream Z Note The default values are user name root and password Password The user name is case insensitive and the password is case sensitive Itis best practice to change the defaults refer to Customize the user name password on page 13 The pages which next appear depend on whether or not you have begun configuring the FastStream VT 5700 Refer to Configure Virtual Tape on page 7 ATTO FASTSTREAM VT POWERED BY Enter here
65. rver Default IP Address 10 0 0 1 set IPAddress mp1 XXX XXX XXX XXX Requires a SaveConfiguration Restart command get IPAddress mp1 IPDHCP Selecting DHCP allows the FastStream to request an IP address from the network The network must have at least one DHCP server Default enabled set IPDHCP mp1 enabled disabled Requires a SaveConfiguration Restart command get IPDHCP mp1 IPGateway Controls the current default gateways used by the Ethernet port on the unit If IPDHCP is enabled the get command reports the current IP gateway assigned by the network DHCP server Default 0 0 0 0 set IPGateway mp1 xxx xxx xxx xxx Requires a SaveConfiguration Restart command get IPGateway mp1 IPSubnetMask Sets displays the current subnet mask If IPDHCP is enabled get command reports current subnet mask assigned by DHCP server Default 255 255 0 0 set IPSubnetMask xxx XXX XXX XXX Requires a SaveConfiguration Restart command get IPSubnetMask xiii IsReserved Displays the reservation status of the FastStream IsReserved MaxOpTemp Regulates the maximum operating temperature of this unit in degrees Celsius Valid entries are between 55 C and 70 C Default 70 set MaxOpTemp 55 70 Requires a SaveConfiguration Restart command get MaxOpTemp Metrics Controls the collection of standard data metrics within a product via the command s Start Stop and Display parameters Metrics Start Stop
66. s to measure performance for physical drives attached to the FastStream during normal system operation and drive initialization and verification Monitor VTL page The Monitor VTL page is the first page you see when you open the ExpressNAV interface after setting up at least one VTL See Exhibit 3 0 1 Each VTL has its own tab Information displayed includes RAID Level RAID status capacity the Fibre Port and LUN to which the VTL is mapped Exhibit 3 0 1 The Monitor VTL page A CAUTION New performance data is updated every 60 seconds which impacts performance slightly even if you minimize the browser window Exit the ExpressNAV interface completely whenever you need maximum performance the element element type and contents and the percentage of capacity used To get further information or to manage the VTL click on the menu items on the left hand side of the screen To return to this screen click on VTL ATTO FASTSTREAM VT ATTD Technology Inc eRe System Status r I Capacity Monitor J RAID Level RAID Status GB Full Manage Diagnostics J RAIDS DEGRADED 33 19GB 0 Advanced Barred ce Capacity of each tape 16 59GB ATTO Element Status Write FP LUN Protected Element Type Bar Code Full 10 nia Medium Transport 11 nia Tape Drive YES Slot 0 YES Slot ATTO 0 nia Slot nia Slot 15 ATTO Technology Inc FastStream VT 5700 Installation and Operation Manual Health
67. se the Quick Configuration or Custom Setup e Quick Configuration quickly generates a Virtual Tape Library after you answer a few key questions The procedure uses all attached storage to build a single VTL If you want to initially create more than one VTL use custom setup You may modify this configuration after initial setup Custom Setup allows you to configure the FastStream VT to best suit the needs Initialize and verify drives Before creating any VTL initialize and verify your drives to ensure integrity When selected the FastStream VT writes a pattern to the entire drive A CAUTION Selecting Drive Initialization causes all previous storage data on the drive to be erased Make sure all of your information is backed up before initializing drives 1 If you are not already in the ExpressNAV interface type the IP address of your appliance as found in Use the ExpressNAV interface on page 27 in a standard browser click Enter Here and type in your user name and password 7 performance and level of reliability for your application If you want to initially create more than one VTL use custom setup You may change the configuration later however changing configuration erases data and may affect performance Backup all previously stored data and plan carefully Read all information and warnings A CAUTION Selecting Commit during configuration causes all previous storage data on the drive to be erased Make s
68. stallation and Operation Manual Use custom setup Custom Setup allows you to configure the FastStream VT to best suit the needs performance and level of reliability for your application If you want to create more than one VTL use custom setup You may create up to two VTLs 1 If you are not already in the ExpressNAV interface type the IP address of your appliance as found in Interface options on page 27 ina standard browser click Enter Here and type in your user name and password 2 On the Initial Setup page choose the Custom Setup button Select User Process O initialize and Verify Drives O System Configuration O Quick Configuration Custom Setup 3 Click on Next 4 Type a name for your Virtual Tape Library in the box provided on the page under the Step 1 heading e In Step 2 select a RAID level Refer to Designing RAID groups on page iii in the Appendix for more information Click on the Hot Spares radio button if you want a Hot Spare Refer to Use Hot Spares on page 11 5 In Step 3 click on the System Scan button to discover the drives available for VTL configuration 6 When the scanned drives box is populated select the drives to be used for the underlying RAID group associated with the VTL The Minimum Number Additional Drives Required heading lists the number of drives you must add to fulfill the RAID level and Hot Spare requirements you have already selected 7 Answer the questions in Step 4
69. stems and levels when event logging is enabled The specific entries supported are platform dependent Default all all all set EventLogFilter subsys all event level all all none get EventLogFilter subsystem all level all Exit Ends the current Ethernet telnet CLI session it has no effect if used during a serial CLI session Exit FCConnMode Controls reports the connection mode the FastStream uses when communication across a FC network either to a Fibre Channel Arbitrated Loop FC AL when you select loop mode or point to point when you choose ptp Ifyou choose loop ptp or ptp loop the FastStream tries to use the first parameter first Default loop set FCConnMode fp loop ptp loop ptp ptp loop Requires a SaveConfiguration Restart command get FCConnMode fp all ATTO Technology Inc FastStream VT 5700 Installation and Operation Manual FCDataRate Specifies the rate the FastStream uses 1 Gigabit sec 2 Gigabit sec 4 Gigabit sec or auto negotiate Default auto set FCDataRate fp all 1Gb 2Gb 4Gb auto Requires a SaveConfiguration Restart command get FCDataRate fp all FCHard Used to enable or disable FC hard address assignment Under soft addressing the FastStream loop address is assigned during loop initialization If you enable hard addressing use F CHardAddress described below Default disabled set FCHard enabled disabled Requires a SaveConfiguration Res
70. system before it is implemented method to operate and manage the The restart can be accomplished as part of the FastStream VT 5700 Refer to Interface SaveConfiguration command or by using a options on page 27 for details separate FirmwareRestart command A The command line interface CLI is a set of l number of set commands may be issued before ASCII based commands which perform the SaveConfiguration command configuration and diagnostic tasks Refer to Responses to set commands are either an error Interface options on page 27 message or Ready The asterisk indicates CLI commands are context sensitive and you must use a SaveConfiguration command generally follow a standard format to finalize the set command Set commands which do not require a SaveConfiguration command defined as immediate commands are immediately executed Get Set Command Parameterl Parameter2 followed by the return or enter key e CLI commands are case insensitive you may type all upper or all lower case or a mixture Upper and lower case in this manual and the x Note help screen are for clarification only Using certain CLI commands during normal Commands generally have three types of operation can cause a performance drop operation get set and immediate Once command actions are complete performance should return to normal levels Exhibit A 6 Symbols typefaces and abbreviations used to indicate functions and elements of the command line
71. t Spares using unallocated drives ones which were not online during initial set up ensure they are properly set up Refer to Initialize and verify drives on page 7 1 If you are not already in the ExpressNAV interface type the IP address of your appliance as found in Use the ExpressNAV interface on page 27 in a standard browser click Enter Here and type in your user name and password 2 The Monitor VTL page appears On the left hand side menu click on Manage 3 On the Manage VTL page click on the FastStream arrow Select User Process B Virtual Tape Libraries B RAID Groups Y FastStream VT AddRemove Hot Spares C System Configuration Set Up Error Notification 4 Click on the Add Remove Hot Spares button Click on Next 6 The Add Remove Hot Spares page appears Follow the on screen directions When you complete your changes click on Commit oa ATTO Technology Inc FastStream VT 5700 Installation and Operation Manual Exhibit 2 2 1 Various screens throughout the ExpressNAV interface show you the status of drives including Hot Spare designations Drives W Drives Configuration Drive Health J _ System Scan jJ Port 3 Drives 17 1068 17 10GB 17 10GB 17 10GB Hot Spare ONLINE ONLINE ONLINE Port 4 Drives 1 0GB 1 0GB 1 0GB 1 0GB 1 0GB ONLINE ONLINE ONLINE ONLINE ONLINE 1 0GB 1 0GB 1 0GB 1 0GB 1 0GB ONLINE Hot Spare ONLINE ONLINE ONLINE 1 0GB 1 0GB 1 0GB 1 0GB ONLINE ONLINE ONLINE O
72. tStream name Identifying information as well as the most recent entries from the event log appear below KAKKKK KKK KK KK KKK Unit Information Serial Number Serial Number IP Addresses IP Addressl IP Address2 Event Log Entries ten latest KKKKKKKKKKKKKKK Listing of th KAKAAAKAAAAAAAAA KAKAAAAAAKAAAAAAA vent log entries 18 Identify drive issues The FastStream VT collects various metrics to measure performance for physical drives attached to the FastStream during normal system operation and drive initialization and verification Preliminary steps 1 If you are not already in the ExpressNAV interface type the IP address of your appliance as found in Use the ExpressNAV interface on page 27 in a standard browser click Enter Here and type in your user name and password 2 The Monitor VTL page appears On the menu at the left hand side of the page click on Diagnostics 3 The Diagnostics Menu page appears Click on the button for the process you wish to use r Select User Process initialize and Verity Drives O Read Only Drive Test Drive Performance and Health O Identity Drive O Clean RAID Configuration Data Initialize and verify drives You may verify the status of storage which does not belong to a RAID group unattached storage If the verify operation detects an error the FastStream tries to re initialize the drive erasing information stored on the drive
73. tart command get FCHard FCHardAddress Sets displays the value used as the FC AL hard address This hexadecimal value represents the address the FastStream tries to use if hard addressing is enabled When an address is not set the current value is displayed The valid range of values is 0 through 125 Default fp1 3 fp2 4 set FCHard Address fp address Requires a SaveConfiguration Restart command get FCHardAddress fp all FCMultiNode When enabled multi node each port reports a separate unique Node Name and logical units may be mapped to any port When disabled single node each port reports the same Node Name and each logical unit map is applied to all ports Ud Note Changing the state of this parameter deletes all existing maps Add new maps using the AutoMap or Route commands Default disabled set FCMultiNode enabled disabled Requires a SaveConfiguration command get FCMultiNode FCPortErrors Displays the number of Fibre Channel errors that have occurred since the last reboot power on or use of the ResetFCPortErrors command get FCPortErrors FCPortList Returns a list of available FC ports and their current status Valid status values are Up Down Failed Reserved and Disabled FCPortList FCTargets Lists all target devices available on the Fibre Channel port with the index specified by fp If no port index is specified all target devices on all Fibre ports are displayed A port unique
74. th Step 4 in this process typing in a name for your VTL 11 The Virtual Tape Library Setup page appears e Click on Done if you do not want to create another VTL e Click on Configure Another to create another VTL Begin the process from Step 4 in this process 2 2 Use Hot Spares If a member of a Virtual Tape Library becomes degraded or faulted you lose some redundancy in your VTL until a new member is rebuilt into the VTL However Hot Spare drives may be designated as replacements for faulted drives without intervention by you or a host The ATTO FastStream VT 5700 replaces degraded or faulted virtual drives ina VTL without intervention by you or a host if you set up a pool of Hot Spare drives of different sizes appropriate for your VTL Hot Spares may be set up by the FastStream VT 5700 automatically depending on your choices during initial setup TX Note Drives in the Hot Spare pool should be of appropriate size to the RAID group so that smaller drives are not replaced by much larger Hot Spare devices When the ATTO FastStream VT 5700 detects a faulted drive e The Controller searches the Hot Spare pool for the smallest drive of sufficient size to substitute for the faulted drive e The FastStream replaces the faulted drive with the drive from the Hot Spare pool e The FastStream begins an automatic rebuild of the RAID groups XX Note A RAID rebuild may take up to two hours to complete 11 If you are adding Ho
75. tion Manual WrapEventLog When enabled the FastStream logs up to 2 048 event entries before wrapping overwriting the first entries If disabled the FastStream stops logging event entries when the buffer is full Default enabled set WrapEventLog enabled disabled Requires a SaveConfiguration command get WrapEventLog zModem Uses the zMODEM protocol to transfer a file to or from the unit via the RS 232 port The filename to retrieve is required if the send option is specified Zmodem send filename receive xviii Appendix D Standards and compliances The equipment described in this manual generates and uses radio frequency energy If this equipment is not used in strict accordance with the manufacturer s instruction it can and may cause interference with radio and television reception See the ATTO FastStream VT 5700 Technical Specification sheet for your particular model for a full list of certifications for that model eee FCC Standards Radio and Television Interference FC pulsed This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause interference to radio communications It has been tested and found to comply with the limits for a Class A computing device pursuant to the FCC rules Title 47 of the CFR Part 15 Subpart B which are designed to provide a reasonable protection against such interference when operating in a c
76. ual Tape Library Setup page and you can choose to begin this procedure again by following the directions in Step 4 of Use custom setup on page 10 Or to get back to the Quick Initial Configuration page exit out of ExpressNAV and restart the process at Step 1 of the Use quick initial configuration procedure The VTL Setup page appears Click on Done The Monitor VTL page appears Exhibit 2 1 1 shows a Monitor VTL page m X Note To configure another VTL you must connect or power up drives which were not available before beginning the Quick Configuration procedure Connect the drives click on Configure Another and the VTL Custom Configuration page appears Continue with the procedure listed under Use custom setup on page 10 Exhibit 2 1 1 The ATTO FastStream VT Monitor VTL page ATTO FASTSTREAM VT Menu Items VTL __ Monitor RAID Level RAID Status Full Manage J Diagnostics RAIDS DEGRADED 33 19GB 0 Advanced j Powered by ATTO Element Status Write FP LUN Protected Element Type Bar Code 10 nia Medium Transport 11 nia Tape Drive YES Slot ATTOVT8e5380000 Slot ATTOVT8e580001 nia Slot nia Slot nia Slot nia Slot nia Slot nia Slot nia Slot nia Slot nia Slot nia Slot nia Slot nia Slot nia Slot nia Slot nia Slot nia Slot nia Slot nia Slot Slot Sint System Status Capacity of each tape 16 59GB ATTO Techno 9 ATTO Technology Inc FastStream VT 5700 In
77. ure all of your information is backed up Before beginning these procedures ensure drives are reliable by initializing and verifying the drives in your system Select User Process Initialize and Verify Drives O System Configuration O Quick Configuration O Custom Setup 2 Fromthe Initial Setup page choose Initialize and Verify Drives Click Next Select Initialize and Verify 5 All eligible drives are highlighted in green the system only initializes highlighted drives Ensure only the drives you are initializing are selected Click Commit A CAUTION Do not restart the FastStream or disconnect or power cycle drives during drive initialization and verification or you must start the verification process from the beginning Rw ATTO Technology Inc FastStream VT 5700 Installation and Operation Manual Use quick initial configuration Quick Configuration generates a Virtual Tape Library after you answer a few key questions The procedure uses all attached disks to build a single VTL If you want to initially create more than one VTL use Custom Setup Refer to Use custom setup on page 10 You may modify this configuration after initial setup 1 If you are not already in the ExpressNAV interface type the IP address of your appliance as found in Use the ExpressNAV interface on page 27 in a standard browser click Enter Here and type in your user name and password 2 From the Initial Setup page choose Qu
78. vation for the current CLI session If the command reports that Reservations are enabled then another CLI session has control of parameter modification on the unit Reserve ResetFCPortErrors ResetFCPortErrors resets all Fibre Channel error counts for the specified port to zero Refer to FCPortErrors ResetFCPortErrors fp all RestoreConfiguration Issued with the default option forces the unit NVRAM settings to their original defaults The saved option undoes any changes made to this session since the last save RestoreConfiguration lt Default Saved gt RGAddStorage Adds additional storage to an existing RAID group Mirror Stripe Span specifies the method used to expand the storage Optional parameter BlockDevID specifies available block device s to be added to the RAID group Optional parameter commit specifies that the RGCommit command is run automatically XK Note Mirrors cannot be added to a RAID 5 group RGAddStorage GroupName Mirror Stripe Span lt BlockDevID gt lt commit gt RGCancelAddStorage Cancels the RGAddStorage command RGCancelAddStorage GroupName xiv RGCommit Stamps a new RAID group s configuration to its member drives After this command a RAID group can be considered operational and transitions from the new state to online degraded or offline depending on the health of the selected member drives Also stamps an existing RAID group s configuration to its member drives wh
79. xpressNAV interface on page 27 in a standard browser click Enter Here and type in your user name and password 2 The Monitor VTL page appears In the left hand menu click on the Manage VTL menu item on the left side of the screen 3 Click on the Other Devices arrow Select User Process _J B Virtual Tape Libraries B RAID Groups B FastStream VT W Other Devices Find ATTO Devices O Set Appliance Name Click Next Click on the Rescan button Select a device from the list Press the Identify button to activate a blinking LED on the selected product Click on the listed device again to stop the blinking LED e Click on the device from the list and click on the Launch in Browser button to view the device s management console OOO A Create a name for your FastStream You may wish to name your FastStream VT if you are going to manage several ATTO devices from one browser 1 Click on Set Appliance Name 2 Click on Next 3 Enter the name in the text box provided on the System Configuration page 4 Click Commit 3 0 Monitor storage configurations You may monitor storage and determine the performance of drives attached to the FastStream VT using various displays and tests in the ExpressNAV interface If you have set up at least one Virtual Tape Library refer to Configure Virtual Tape on page 7 you may monitor various aspects of your storage and the VT and to view various metric
80. y a server for an invalid address Each E mail is time stamped when it leaves as part of the SMTP header information as shown in Exhibit 3 0 4 1 If you are not already in the ExpressNAV interface type the IP address of your appliance as found in Use the ExpressNAV interface on page 27 in a standard browser click Enter Here and type in your user name and password 10 12 13 The Monitor VTL page appears On the menu at the left hand side of the page choose Manage The Manage VTL page appears Click on the FastStream VT arrow Click the Set up Error Notification button Select User Process B Virtual Tape Libraries B RAID Groups Y FastStream VT O Add Remove Hot Spares O System Configuration Set Up Error Notification B Other Devices Click Next Click on the Notification Configuration Enabled button Type in the sender address E mails show this name in the From field Type in the SMTP Server IP Address Type in the user name and password of your SMTP E mail account Type in up to five E mail addresses Choose All Critical Warning or Informational for each E mail address When all information is typed in click Commit Your settings are displayed You may change or disable E mail notification at any time Exhibit 3 0 4 The E mail messages sent by the FastStream VT 5700 follow this format Subject The Type of Event that Occurred Message Body This is a status message from Fas
Download Pdf Manuals
Related Search
Related Contents
Télécharger le manuel d`utilisation PDF Sony DSC-N1 User's Manual 4X4 Driver Shield Manual ZyXEL Communications 310 Network Router User Manual Emulex® Drivers Version 10.4 for Windows Jets vacuum piping guide (published Wentronic E14 Ambient 360°CD MANUAL - Damalini Manual Chantons Noël ! - La Seyne-sur-Mer Copyright © All rights reserved.
Failed to retrieve file