Home
Panasonic CW-XC184HU Air Conditioner
Contents
1. Lock Nut 4 to i Fy e E Top retainer bar is in product package Suggested Tool Requirements SCREWDRIVER RULER KNIFE HAMMER PENCIL LEVEL PREPARATION OF CHASSIS 1 Remove the screws which fasten the cabinet at both sides and at the back See Fig 1 Shipping screws D Slide the unit out from the cabinet by gripping the base pan handle and pulling forward while bracing the cabinet See Fig 2 ao Cut the window sash seal to the proper length Peel off the backing and attach the Foam PE to the underside of the window sash See Fig 3 gt Remove the backing from Foam PE with 3 holes and attach it to the bottom of the Top retainer bar See Fig 3 O1 Attach the Top retainer bar the top of the cabinet with 3 screws Type A See Fig 4 o Insert the Frame Curtain into the Top retainer bar and Lower guide See Fig 4 A Fasten the curtains to the unit with 10 screws Type A at both sides See Fig 4 Foam PE Top retainer bar Screw Type A Fig 4 Cabinet Installation 1 Open the window Mark a line on the center of the window stool between the side a a window stop moldings sit 52 Support Loosely attach the sill bracket to the support Carriage sen bracket using the carriage bolt and the lock M Screw nut See Fig 5 Fig 5 2 Attach the sill bracket to the window sill using the screws Type B Carefully place the cabinet
2. will repair this product with new or refurbished parts in case of defects in material or workmanship free of charge in the USA or Puerto Rico in accordance to the following All time periods start from the date of the original purchase SEALED REFRIGERATING SYSTEM compressor and interconnecting tube FIVE 5 YEARS PARTS AND LABOR ALL OTHER COMPONENTS ONE 1 YEAR PARTS AND LABOR In home service in the USA can be obtained during the warranty period by contacting a Panasonic Service Company PASC Factory Servicenter listed in the Servicenter Directory Or call toll free 1 800 211 PANA 7262 to locate a PASC authorized Servicenter In home service in Puerto Rico can be obtained during the warranty period by calling the Panasonic Sales Company telephone number listed in the Servicenter Directory Note If the unit is installed at the other than normal window height and or has been custom installed e g through the wall the customer is responsible for removing the unit from its installation prior to the performance of in home service This warranty is extended only to the original purchaser A purchase receipt or other proof of date of the original purchase is required for service and parts replacement under this warranty This warranty only covers failures due to defects in materials and workmanship and does not cover normal wear or cosmetic damage The warranty does not cover damages which occur in shipment or failures which ar
3. DE AIRE T7777 ar GABINETE REJILLA FRONTAL FILTRO DE AIRE RECOLECTOR DE AIRE BANDEJA DE ENTRADA SUSPENSORES COMPRESOR CONDENSADOR EVAPORADOR BANDEJA PANEL DE CONTROL CABLE DE CONEXI N EL CTRICA CONTROL REMOTO Instrucciones de Instalacion Elija el major lugar DE CALOR APROXIMADAMENTE 14 _ARRIBA DE 20 1 Para evitar vibraci n y ruido asef rese de que la unidad est instalada de manera segura y firmemente 2 Instale la unidad en lugares fuera de luzsolar directa directamente sobre la unidad 3 El exterior del gabinete deber extenderse hacia afuera cuando menos 10 y no deben existir obst culos tales como una barda o pared dentro de una distancia de 20 desde la pparte posterior del gabinete porque esto evitar la radiaci n de calor del condensador La restricci n del aire exterior reducir en gran manera la eficiencia de enfriamiento del aire acondicionado PRECAUCION Todas las persianas laterales del gabinete deber n permanecer expuestas al exterior de la estructura 4 Para prevenir la reducci n de la eficiencia del funcionamiento instale la unidad para que las rejillas del cabinete no sean bloqueados 5 Instale la unidad un poco oblicuamente hacia afuera para no dejar escapar el agua condensado a la habitaci n aproximadamente 1 2 o 1 4 ampolla con nivel 6 Llene la espuma entre el tope de la unidad y la pared para prevenir que
4. direct air flow Do not apply an insecticide Do not operate switches or flammable spray with wet hands e It may cause imperfect It may cause a fire or deformation combustion e It may cause an electric shock of the cabinet About the Controls on the Air Conditioner Controls Models CW XC184HU CW XC244HU MODE FAN SPEED ECONOMY Panasonic Precaution The Remote Controller will not function properly if strong light strikes the sensor window of the air conditioner or if there are obstacles between the Remote Control unit and the air conditioner YA OPERATION BUTTON 16 ON OFF TIMER BUTTON To turn the air conditioner ON push the You can set the time when the unit will turn on or turn button To turn the air conditioner OFF push off automatically by pressing the timer button If the the button again e This button takes priority over any other buttons e When you first turn it on the air conditioner is on the High cool mode and the temp at unit is operating this button controls the time it will be turned off If the unit is in off state this button controls the time it will start Every time you push this button the remaining time will be set as follows 72 F 22 C STOPPING OPERATION e Every time you push this button when the air 2 OPERATION MODE SELECTION BUTTON conditioner is operating timer is set as follows Every time you push this button it will toggl
5. el aire e insectos entren en la habitaci n Requisitos de ventana ES 1 Esta unidad est dise ada para instalarse en ventanas de guillotina est ndar con espesor real de abertura de 26 a 41 Los marcos superior e inferior de la ventana dever n abrir lo suficiente para permitir una abertura vertical libre de 18 de la parte inferior del marco superior a la repisa de la ventana 26 to 41 18 min Taburete Pe ait 2 El desplazamiento de la repisa altura entre la repisa A Aifeizar pu 1 y el alf izar debe ser menor a 1 1 4 Exterior I tabaki Contenido del juego de instalacion TIRA DE GOMA CINTA DE ESPUMA PANEL GU A Tapa del desag e SOPORTE DE g CERRADURA S MENSULA SA ALFEIZAR 2 PANEL GU A TUERCA DE SEGURIDAD 4 2 E La barra de retenci n superior esta en el empaque del producto Requisitos de las herramientas sugeridas DESARMADOR REGLA CUCHILLO MARTILO LAPIZ NIVEL PREPARACION DEL CHASIS 1 Retire los 4 tornillos que unen el gabinete a la parte posterior y lateral de la unidad Ver Fig 1 D Deslice la unidad fuera del gabiete tomando la manija de la charola de la base y jale hacia adelante mi ntras sostiene el gabinete Ver Fig 2 ao Corte el sellode chasis de la ventana a la longitud apropiada Pele el resfuerzo y aplique la Cinta de Espuma a la parte inferior del chais de la
6. enciende por primera vez el sistema 2 Horas gt 3 Horas gt 4 Horas gt 5 Horas gt est en el y la temperatura es de 72 F 22 C 6 Horas gt 7 Horas gt 8 Horas gt 9 Horas gt El nr este bot n las palabras la temperatura de ajuste o COOL ECONOMY FAN y DRY aparecer n ee AR y otros 2 F 1 C media alma cama OPERACI N DE INICIACI N E AJUSTE DE LA TEMPERATURA Cada vez que presione este bot n cuando el Este bot n puede controlar la temperatura del sistema est operando el marcador de tiempo cuarto autom ticamente La temperatura se se ajustar de la siguiente manera 1Hora gt puede ajustar de grado en grado desde 60 F 2 Horas gt 3 Horas gt 4 Horas gt 5 Horas gt hasta 86 F cada 1 F 16 C hasta 30 C cada 6 Horas gt 7 Horas gt 8 Horas gt 9 Horas gt 1 C Seleccione el numero mas bajo para la 10 Horas gt 11 Horas gt 12 Horas gt 0 Hora temperatura mas baja en el cuarto 70 AUTOGIRD 7 VELOCIDAD DEL VENTILADOR e Este bot n puede controlar autom ticament la Cada vez que presione este bot n el ajuste es direcci n del flujo de aire como sigue Alto F3 gt Bajo F1 gt Medio F2 gt 8 RECEPTOR DE SE AL Alto F3 5 AHORRADOR DE ENERGIA 9 DRY El ventilador se detiene cuando el compressor no Cuando esta unidad se torna al modo seco el sigue enfriando ventilador gira en velocidad lenta El ventilador se Aproximadamente cada 3 minutos el ventilador se detiene cuando el
7. gabinete PEN E ELETRICA TORNILLO TIPO A AI 10 8 Corte la tira de goma a la medida apropiada e introd zcala entre la parte superior e inferior de la ventana Ver Fig 11 9 Se debe instalar el asa antes de fijar el frente decorativo Ver Fig 12 UA 10 Instale la rejilla frontal en el cabinete insertando la leng eta en la rejilla a la leng eta en el frente del cabinete Empuje la rejilla hasta que se cierre con sonido de golpe Ver Fig 13 11 Levante la rejilla de entrada y aseg rela con un tornillo tipo A a trav s de la rejilla frontal Ver Fig 13 NOTA Se refiere por favor p 20 para poner juego de ventilaci n 12 Ahora la instalaci n del aire acondicionado en la ventana es completada Vea los DATOS ELECTRICOS para instalar el cable de alimentaci n en la toma de corriente Datos Electricos Para modelo de 230 208V Solamente Corc n El ctrico Utilice el enchufe de la pared No lo corte bajo ninguna circunstancia o remueva la punta del enchufe Cord n el ctrico con Standard 250V enchufe de 3 puntas para enchufar L neas de 15A 250V AC No lo corte bajo ninguna circunstancia o remueva la punta del enchufe Cord n el ctrico con Standard 250V enchufe de 3 puntas para enchufar L neas de 20A 250V AC Consumo de Energ a Utilice un fusible de 15AMP o un Interruptor de 15AMP Utilice un fusible de 20AMP o un In
8. humidity or on rainy days The water may overflow and drip from the outdoor side of the unit e The fan may run even when the compressor does not Abnormal Operation E The air conditioner is unplugged E The fuse is blown circuit e Make sure the air conditioner plug is pushed completely into the outlet e Check the house fuse circuit breaker box and Air conditioner ai does not start breaker is tripped replace the fuse or reset the breaker E Power failure e When power is restored wait 3 minutes to restart the air conditioner to prevent tripping of the compressor overload E Airflow is restricted e Make sure there are no curtains blinds or furniture _ blocking the front of the air conditioner E TEMP Control set to a e Set the TEMP Control to a lower number higher number Air conditioner E The air filter is dirty e Clean the filter at least every 2 weeks does not cool as it See the operating instructions section Pong E The room may have been When the air conditioner is first turned o on hot you need to allow time for the room to cool down Cold a air is gt escaping Check for open furnace floor registers and cold air returns e Set the air conditioner s vent to the closed position E Cooling coils have iced up See Air Conditioner Freezing Up below E Air conditioner E Ice blocks the air flow and Set the mode control at High Fan or High Cool with freezing up stops the air condition
9. of the drain pan You can purchase the drain ee hose or tubing locally to satisfy your particular needs Drain hose is not supplied See Fig 3 Select the most appropriate connection from among ETS the figures to the right by considering the hole of the BRAIN 7 SET DRAIN HOSE unit to fit drain pan to your own unit See Fig 3 SCREW Fig 3 5 Slide the chassis back into the cabinet Reinstall the cabinet screws Secure the cabinet to chassis by T H _ D Fig 2 CABINET S using screws See Fig 4 Fig 4 O Care and Maintenance TURN THE AIR CONDITIONER OFF AND REMOVE THE PLUG FROM THE POWER OUTLET Air Filter Cleaning The air filter behind the front grille should be checked and cleaned at least once every 2 weeks or more often if necessary TO REMOVE 1 Open the inlet grille upward by pulling out the bottom of the inlet grille or downward by pulling out the top of the inlet grille 2 Using the tab pull up slightly on the filter to release it and pull it down or up 3 Clean the filter with warm soapy water below 40 C 104 F 4 Rinse and gently shake the water from the filter and let it dry before replacing it CAUTION DO NOT operate the air conditioner without a filter because dirt and lint will clog it and reduce performance How to insert batteries e Do not use rechargeable batteries Such batteries differ from standard dry cells in shape dimen
10. on the window Machine PNTE D stool and align the center mark on the Cabinet b f ith th li Red Track hole Outer edge ottom ront with t e center line marke of window window stool See Fig 6 Support sill Bracket Carriage bol Screw Type B and lock nut Sill bracket Fig 6 3 Using the M screw and the lock nut attach the support bracket to the cabinet track hole Use the first track hole after the sill bracket on the outer edge of the window sill Tighten the carriage bolt and the lock nut Be sure the cabinet slants outward See Fig 6 CAUTION DO NOT DRILL A HOLE IN THE BOTTOM PAN The unit is designed to operate with approximately 12 7mm 1 2 of water in bottom pan 4 Pull the bottom window sash down behind the Top retainer bar until they meet See Fig 7 Sash track NOTE 1 Do not pull the window sash down so tightly that the movement of Frame curtain is restricted Attach the UNS Front Angle cabinet to the window stool by Screw Type B Fig 8 driving the screws Type B through the cabinet into window stool See Fig 8 2 The cabinet should be installed with a very slight tilt downward toward the outside 5 Pull each Frame curtain fully to each window sash track and pull the bottom window sash 5 Screw Type C down behind the Top retainer bar until it R d meets SS 6 Attach each Frame curtain the window sash by using screws Type C See Fig 9 F
11. problemas encontrar respuestas a la mayor a de los problemas m s comunes Si consulta primero la tabla de Sugerencias para la resoluci n de problemas quiz ni siquiera necesite avisar al servicio t cnico PRECAUCION e Consulte con el servicio t cnico autorizado sobre la reparaci n o el mantenimiento de esta unidad El acondicionador de aire no debe ser utilizado por ni os peque os o personas inestables sin supervisi n Es preciso vigilar a los ni os peque os para asegurarse de que no juegan con el acondicionador de aire 16 Precauciones Importantes de Seguridad Para prevenir tanto lesiones al usuario u otras personas como da os materiales es preciso seguir estas instrucciones E El manejo incorrecto debido a la inobservancia de estas instrucciones puede causar lesiones o da os cuya gravedad est clasificada en las siguientes indicaciones A ADVERTENCIA Este s mbolo indica la posibilidad de lesiones mortales o graves A PRECAUCION Este s mbolo indica la posibilidad de lesiones o da os materiales E El significado de los s mbolos utilizados en este manual se indica a continuaci n OTG Conecte correctamente el enchufle De otra forma ello ocasionar a una descarga el ctrica o incendio a causa de la generaci n de calor No modifique el largo del cable el ctrico y tampoco comparta el tomacorriente con otros aparatos e Ello ocasionar a una descarga el c
12. 20 AMP circuit breaker All wiring should be made in accordance with local electrical codes and regulations NOTE Aluminum house wiring may pose special problems Consult a qualified electrician E ELECTRICAL SAFETY IMPORTANT GROUNDING INSTRUCTIONS Air conditioner has a three prong grounding plug on its power supply cord which must be plugged into properly grounded three prong wall receptacle for your protection against possible shock hazard AN 230 208 and 230 208 VOLT UNITS These units are equipped with a three prong grounding plug on the power supply cord which must be plugged into a matching properly grounded three prong wall receptacle for your protection against possible shock hazard If such an outlet is not present one must be installed by a qualified electrician in accordance with the National Electrical Code and local codes and ordinances NOTE DO NOT USE AN EXTENSION CORD ON 230 208 AND 230 208 VOLT UNITS Before you call for service Troubleshooting Tips Save time and money Review the chart below first and you may not need to call for service Normal Operation e You may hear a pinging noise caused by water being picked up and thrown against the condenser on rainy days or when the humidity is high This design feature helps remove moisture and improve efficiency e You may hear the relay click when the compressor cycles on and off e Water will collect in the base pan during high
13. BANDEJA EVAPORADORA se llene de agua Para quitar el agua acumulado es preciso conectar el tubo de desag e Quite la TAPA DEL DESAGUE y conecte el TUBO a la BANDEJA EVAPORADORA Ver Fig 1 Opcional CW3H02502C 1 Retire el tap n de pl stico y deslice el chasis fuera del armario Ver Fig 2 2 Instale la bandeja de drenaje por encima de la esquina de la tapa de donde retir el tap n con 4 0 2 Sea tornillos Ver Fig 3 3 Conecte la manguera de drenaje a la salida situada en la parte inferior de la bandeja de drenaje Puede adquirir e una manguera de drenaje o una tuber a apropiada en su e o localidad que satistaga sus necesidades particulares la pe seta manguera no se suministra Ver Fig 3 z 4 Seleccione la conexi n m s apropiada entre las figuras siguientes teniendo en cuenta el orificio de la unidad O la bandeja de drenaje en su unidad Ver BREA fi MANGUERA DE DRENAJE 19 TORNILLOS Fig 3 5 Deslice el chasis en el interior del armario Vuelva a apretar los tornillos del armario Fije el armario c al chasis con tornillos Ver Fig 4 E ay ne al oa nw ees Fig 4 Cuidado y Mantenimiento APAGUE EL AIRE ACONDICIONADO Y SAQUE EL ENCHUFE DEL TOMA CORRIENTE DE LA PARED Limpieza de filtro de Aire Lil El filtro de aire detras de la rejilla frontal debe ser revisado y limpiado por lo menos una vez por cada dos semanas o mas frecuentemente si es necesario PARA R
14. EMOVER 1 Abra la rejilla hacia arriba tirando la parte inferior de la rejilla o hacia abajo tirando la parte superior de la rejilla 2 Usando una leng eta tire el filtro ligeramente hacia arriba para sacarlo por abajo o arriba 3 Limpie el filtro con agua tibia y jabonosa bajo 40 C 104 F 4 Enjuague y sacuda el filtro suavemente bajo la corriente de agua y d jelo secar antes de reponerlo PRECAUCION NO OPERE el aire acondicionado sin filtro ya que la suciedad y el tamo obstruir el filtro y reducir la eficiencia del funcionamiento C mo poner las bater as e No utilice bater s recargables stas son diferentes de forma de dimensi n y uso respecto a las bater as secas usuales 7 Quite la tapa de la parte posterior del telemando Para ello haga deslizar la tapa seg n la direcci n del la flecha 2 Introduzca las dos AAA c lula seca bater as asegur ndose de que las direcciones y est n colocadas correctament Use bater as nuevas Seque las bater as del telemando cuando el acondicionador no vaya a ser usado durante un largo per odo 3 Volver a cerrar resbalando la tapa hasta la posici n inicial Caracteristicas Aprender el nombre de las partes antes de la instalaci n le ayudar a entender el proceso de instalaci n Caracter sticas DEFLECTOR DE AIRE HORIZONTAL VENTANILLAS HORIZONTALES DEFLECTOR HORIZONTAL DE AIRE VENTANILLAS VERTICALES SALIDA
15. IDIT DESHUMIDIFICACION Pints h pinte h Tinta h 5 5 7 5 ROOM CIRCULATION CIRCULATION D AIR CIRCULACION DE AIRE Cf min pi min pie min 459 477 DIMENSIONS DIMENSIONS DIMENSIONES Height Hauteur Alto Width Largeur Ancho Depth Profondeur Profundidad al inches pouces pulgadas pouces m m inches Deus cm cm cm sl inches m pouces aa pulgadas 42 8 162 32 66 0 26 67 5 2617 32 42 8 162 32 66 0 26 77 0 302 32 NET WEIGHT POIDS NET PESO NETO b livres libras 55 123 66 146 GROSS WEIGHT POIDS BRUT PESO BRUTO b livres libras kg kg kb kg kg Kb Specifications are subject to change without notice for improvement Les sp cifications ci dessus peuvent tre chang es sans pr avis Las especificacionas estan sujetas a cambios por majoras sin previo aviso 62 138 72 161 Nota Panasonic Consumer Electronics Company Panasonic Sales Company Division of Matsushita Electric Corporation Division of Matsushita Electric of Puerto Rico Inc of America Ave 65 de Infanteria Km 9 5 One Panasonic Way San Gabriel Industrial Park Secaucus New Jersey 07094 Carolina Puerto Rico 00985 Panasonic Room Air Conditioner Limited Warranty Panasonic Consumer Electronics Company or Panasonic Sales Company collectively referred to as the Warrantor
16. Panasonic Room Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS modes CW XC184HU CW XC244HU Please read these operating instructions thoroughly before using your air conditioner and keep for future reference For assistance please call 1 800 211 PANA 7262 or Register your product at http www panasonic com register CW382820391D Safety Precautions Safety Precautions 3 About the Controls on the Air Conditioner COM 5 Ventilation 6 Air Direction 6 How to Secure Drain Pipe 6 Care and Maintenance Air Filter Cleaning 7 How to Insert Batteries 7 Features ESO Re ee 8 Installation How to Install the Unit 9 Window Requirements 9 Installation Kit Contents 10 Suggested Tool Requirements 11 Cabinet Installation 12 Electrical Data 14 Electrical Safety 14 Before you call for service Normal Operation Abnormal Operation 0 FOR YOUR RECORDS Staple your receipt to this page in case you need it later Write down the model and serial numbers here Model Serial You can find them on a label on the side of each unit Dealer s Name Date Purchased READ THIS MANUAL Inside you will find many helpful hints on how to use and maintain your air conditioner properly Just a l
17. compresor se para de enfriar encender y necesitar verificar la temperatura Aproximadamente cada 3 minutos se encender del cuarto para saber si es necesario m s el ventilador y la unidad comprueba la enfriamiento temperatura del aire de la habitaci n para ajustarse a si mismo Controles adicionales e informacion importante Ventilaci n La palanca de ventilaci n debe estar en posici n CERRADA para poder mantener las mejores condiciones de enfriamiento Cuando se necesite aire fresco en la habitaci n SNS coloque la palanca de ventilaci n en posici n ABIERTA La Compuerta es abierta y el aire de la habitaci n es expulsado e CERRADO mila VENT alla ABIERTO NOTA Antes de utilizar la caracter stica de ventilaci n haga un kit de ventilaci n Primero hale hacia abajo la parte A hasta que quede horizontal con la parte Como controlar la direccion del aire La direcci n del aire puede ser controlada cuando usted desee enfriar ajustando la palanca vertical y la palanca horiziontal e CONTROL DE LA DIRECCI N VERTICAL CONTROL DE LA DIRECCI N DEL AIRE HORIZONTAL DEL AIRE 4 La direcci n vertical del aire es ajustada La direcci n horizontal del aire es ajustada rotando la palanca horizontal hacia adelanto rotando la palanca vertical hacia la derecha o O hacia atr s hacia la izquierda por Director Remoto Como Installar el Tubo de Desague En climas h medos es posible que la
18. e 1Hour gt 2Hours gt 3Hours gt 4Hours gt 5Hours gt between COOL ECONOMY FAN DRY 6Hours gt 7Hours gt 8Hours gt 9Hours gt 10Hours gt gJ ROOM TEMPERATURE SETTING BUTTON hey A pel eo li i ae r This button can automatically control the Ine Seling Temperature ee raised oy temperature of the room The temperature can 2 F 1 C 30min later and by 2 F 1 C after be set within a range of 60 F to 86 F by 1 F another 30 min 16 C to 30 C by 1 C STARTING OPERATION Select the lower number for lower temperature Every time you push this button when the air conditioner of the room is not operating timer is set as follows tHour gt 2Hours gt 3Hours gt 4Hours gt 5Hours gt 6Hours gt 7Hours gt 8Hours gt 9Hours gt 10Hours gt 11Hours gt 12Hours gt OHour gt 1Hour gt 2Hours gt Z FAN SPEED SELECTION BUTTONS Every time you push this button it is set as follows High F3 gt Low F1 gt Med F2 gt High F3 77 AIR SWING BUTTON This button can automatically control the air S ECONOMY flow direction e If you push this button the fan stops when the 8 REMOTE CONTROL SIGNAL RECEIVER compressor stops cooling Approximately every aa DRY i i 9 3 minutes the fan wil tum oe and check the El When this unit is in dry mode the fan rotates in room air to determine if cooling is needed low speed The fan stops when the compressor stops oin f Approximately every 3 mi
19. e caused by products not supplied by the warrantor or failures which result from accident misuse abuse neglect mishandling misapplication faulty installation maladjustment of customer controls improper maintenance alteration modification power line surge lightning damage improper voltage supply commercial use such as hotel office restaurant or other business or rental use of the product or service by anyone other than a PASC Factory Servicenter or a PASC authorized Servicenter or damage that is attributable to acts of God LIMITS AND EXCLUSIONS There are no express warranties except as listed above THE WARRANTOR SHALL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING FROM THE USE OF THIS PRODUCT OR ARISING OUT OF ANY BREACH OF THIS WARRANTY ALL EXPRESS AND IMPLIED WARRANTIES INCLUDING THE WARRANTIES OF MERCHANTABILITY ARE LIMITED TO THE APPLICABLE WARRANTY PERIOD SET FORTH ABOVE Some states do not allow the exclusion or limitation of incidental or consequential damages or limitations on how long an implied warranty lasts so the above exclusions or limitations may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state If a problem with this product develops during or after the warranty period you may contact your dealer or Servicenter If the problem is not handled to your satisfaction then write to the Consumer Affairs Department at th
20. e company address indicated above SERVICE CALLS WHICH DO NOT INVOLVE DEFECTIVE MATERIALS OR WORKMANSHIP AS DETERMINED BY THE WARRANTOR IN ITS SOLE DISCRETION ARE NOT COVERED COSTS OF SUCH SERVICE CALLS ARE THE RESPONSIBILITY OF THE PURCHASER For assistance please call 1 800 21 1 PANA 7262 or send e mail to consumerproducts panasonic com Printed in Korea
21. er from cooling the room the high temperature Precauciones Importantes de Seguridad Precauciones Importantes de seguridad 17 Instrucciones de Funcionamiento CoNo 19 Ventilaci n a 20 Como controlar la direccion del aire 20 Como installar el Tubo de desag e 20 Cuidado y Mantenimiento Limpieza de filtro de aire 21 C mo poner las Bater as 21 Caracteristicas Caracter sticas 22 Instrucciones de instalaci n Elija el major lugar 23 Requisitos de ventana 23 Contenido del juego de instalaci n e as 24 Requisitos de las herramientas sugeridas 25 Instalaci n del gabinete 26 Datos electricos 28 Seguridad electrica 28 Antes de avisar al Servicio T cnico Operacion normal Operacion anormal 0 PARA SU INFORMACION Escriba aqui los n meros de serie y modelo de las unidades exterior e interior N de Modelo N Serie Los n meros figuran en una etiqueta en el lateral de cada unidad Distribuidor Fecha de compra LEA ESTE MANUAL e Aqui encontrar numerosas sugerencias sobre c mo utilizar y mantener adecuadamente su acondicionador de aire Con unos cuantos cuidados preventivos se puede ahorrar mucho tiempo y dinero a lo largo de la vida til de su acondicionador de aire En la tabla de sugerencias para la resoluci n de
22. ete el perno y la tuerca de seguridad Aseg rese de que el gabinete est inclinado hacia afuera PRECAUCION No perfore la charola del fondo La unidad esta dise ada para operar con aproximadamente 1 2 12 7mm de agua en la charola del fondo 4 NOTA 1 No hale el marco de la ventana hacia abajo tan apretado que se restrinja el movimiento de los deslizadores Sujete el gabinete a la repisa de la ventana insstalando los tornillos tipo Ao B a trav s del gabinete en la repisa de la ventana 2 El gabinete deber ser instalado ligeramente inclinado hacia abajo hacia el exterior MENSULA DEL ALFEIZAR FA DE Pa All BULON ORIFICIO DE CARRIL DE GABINETE MENSULA DE SOPORTE MARCO DE LA DE SOPORTE gt MENSULA TUERCA DE SEGURIDA Fig 5 TORNILLO PARA METALES TIPO D Y TUERCA DE SEGURIDA BORDE EXTERIOR DEL ANTEPECHO DE LA VENTANA TORNILLO TIPO B MENSULA i DEL ALFEIZAR Fig 6 BARRA DE RETENCION SUPERIOR TORNILLO TIPO B Fig 8 5 Hale cada panel guia completamente a cada lado de la ventana y repita del paso 2 TORNILLO Z ZAM TIPO C 6 Adjunte cada panel gu a a cada lado de la pS lt Se ventana usando tornillos Tipo C X Ver Fig 9 gt a Fig 9 7 Deslice el chasis dentro del gabinete Ver Fig 10 CUIDADO Por razones de seguridad re instale S gt los tornillos Tipo A en los lados del CORDON DE ail ALIMENTACION
23. ig 9 7 Slide the unit into the cabinet See Fig 10 CAUTION For security purpose reinstall screws at cabinet s sides Power Cord Screw lt lt Fig 10 8 Cut the Foam strip to the proper length and insert between the upper window sash and the lower window sash See Fig 11 9 Attach the Window locking bracket with a Window locki screw Type C See Fig 12 indow locking bracket 10 Attach the front grille to the cabinet by inserting the tabs on the grille into the tabs on the front of the cabinet Push the grille in until it snaps into place See Fig 13 11 Lift the inlet grille and secure it with two screws Type A through the front grille See Fig 13 NOTE Please refer p 6 for setting ventilation kit 12 Window installation of room air conditioner is now completed See ELECTRICAL DATA for attaching power cord to electrical outlet Electrical Data For 230 208V model only Line Cord Plug Do not under any circumstances cut or remove the grounding prong from the plug Standard 250V 3 wire grounding receptacle rated 15A 250V AC Do not under any circumstances cut or remove the grounding prong from the plug Power supply cord with 3 prong grounding plug Use Wall Receptacle Standard 250V 3 wire grounding receptacle rated 20A 250V AC Power Supply Use 15 AMP time delay fuse or 15 AMP circuit breaker Use 20 AMP time delay fuse or
24. ire e Puesto que el ventilador gira a Esto podr a da ar al animal o a No utilice este acondicionador de alta velocidad durante la la planta aire para conservar dispositivos operaci n podr a ocasionar de precisi n alimentos y objetos heridas de arte no ponga tampoco animales y plantas cerca de l Esto podr a deteriorar la calidad No manipule los No aplique aerosoles con No ponga una estufa etc interruptores con las manos insecticida o productos donde quede expuesta al mojadas inflamables flujo de aire directo Esto podria causar una sacudida Esto podria causar un incendio o Esto podr a causar una el ctrica deformar la caja combusti n imperfecta Instruccionnes de Funcionamiento Controles Modelos CW XC184HU CW XC244HU MODE FAN SPEED ECONOMY Panasonic Precauci n El dispositivo de control remoto no funcionar adecuadamente si la ventana sensora del acondicionador de aire es expuesta a luz fuerte o si hay obst culos entre el dispositivo de control remoto y el acondicionador de aire 7 ENECNDIDO APAGADO 6 MARCADOR DE ENCENDIDO APAGADO Para ENCENDER el sistema presione el bot n y OPERACION DE PARADA para APAGARLO presione el bot n otra vez e Cada vez que presione este bot n cuando el Este bot n tiene prioridad sobre todos los otros sistema est operando el marcador de tiempo botones se ajustar de la siguiente manera 1Hora gt Cuando Ud lo
25. ittle preventive care on your part can save you a great deal of time and money over the life of your air conditioner You ll find many answers to common problems in the chart of troubleshooting tips If you review our chart of Troubleshooting Tips first you may not need to call for service at all CAUTION Contact the authorized Service technician for repair or maintenance of this unit e The air conditioner is not intended for use by young children or infirm persons without supervision e Young children should be supervised to ensure that they do not play with the air conditioner Safety Precautions To prevent injury to the user or other people and property damage the following instructions must be followed E Incorrect operation due to ignoring of instruction will cause harm or damage The seriousness is classified by the following indications A WARNING This symbol indicates the possibility of death or serious injury CAUTION This symbol indicates the possibility of injury or damage to A property only E Meanings of symbols used in this manual are as shown below D Be sure not to do this Be sure to follow the instructions Plug in the power plug Do not operate or stop the Do not damage or use an properly unit by inserting or pulling unspecified power cord out the power plug Otherwise it will cause electric e lt will cause electric shock or fire e It will cause electric shock o
26. ll the unit a little obliquely outward to avoid leaking the condensed water into the room about 1 2 or 1 4 bubble with level 6 Install the unit with its bottom portion 30 60 above the floor level 7 Stuff the foam between the top of the unit and the wall to prevent air and insects from getting into the room 8 The power cord must be connected to an independent circuit The green wire must be grounded 9 Connect the drain tube to the base pan hole in the rear side if you need to drain consult a dealer Plastic hose or equivalent may be connected to the drain tube Window Requirements E NOTE All supporting parts should be secured to firm wood masonry or metal WINDOW REQUIREMENTS 1 This unit is designed for installation in standard double hung windows with actual opening widths from 26 to 41 The top and bottom window sashes must open sufficiently to allow a clear vertical opening of 18 from the bottom of the upper sash to the window stool 2 The stool offset height between the stool INTERIOR WALL 7 and sill must be less than 1 1 4 26 to 41 18 min STOOL OFFSET ee a SILL Installation Kits Contents Foam strip Foam PE Plain Back Adhesive Backed Foam PE Adhesive Backed Left frame curtain Drain pipe Window locking A bracket lt gt Right frame Sill bracket 2 curtain Type 14 Type B 7 Type C 5 Type D 2 Carriage Bolt 2
27. nos cada dos semanas Vea la acondicionado no enfr a corno WE cuarto a n est caliente secci n de instrucciones de operaci n e Cuando usted enciende el aire acondicionado debe debiera esperar un momento para que la habitaci n se enfrie E El aire frio se est e Aseg rese que todas las salidas de aire est n cerradas escapando para que el aire regrese Coloque la ventana del aire acondicionado en la E E EN eee posici n m s cercana E E serpentin de refrigeraci n Establezca una temperatura m s alta se ha congelado El aire E El hielo bloquea el flujo de Ajustar el control de mode en Ventilaci n Alta o acondicionado aire y detiene el Erfriamiento Alto con la temperatura alta enfria dernasiado enfriamiento del cuarto Model Mod le Modelo PRODUCT SPECIFICATION ESPECIFICIONES DEL PRODUCTO CW XC184HU CW XC244HU COOLING CAPACITY CAPACIT DE REFROIDISSEMENT CAPACIDAD DE ENFRIAMIENTO 17 800 17 300 23 500 23 000 ELECTRICAL RATING CARACT RISTIQUES LECTRIQUES CLASIFICION DE LA ELECTRICIDAD Phase Phase Fase Frequency Fr quence Frecuencia Voltage Tension Voltaja Current Courant Single Simple Monofasico 60 230 208 Single Simple Monofasico 60 230 208 11 2 12 0 Corriente Input 1 660 1 620 2 500 2 450 Consommation Potencia EER RENDEMENT NERG TIQUE EER 10 7 10 7 MOISTURE REMOVAL SUPPRESSION D HUM
28. nutes the fan will turn on and the unit checks the room air temperature to set itself Additional controls and important information Ventilation The ventilation lever must be in the CLOSE position in order to maintain the best cooling conditions SE When fresh air is necessary in the room set the ventilation lever to the OPEN position The damper is opened and room air is drawn out CLOSE alla VENT all OPEN NOTE Before using the ventilation feature and prior to installing the front grille pull down part A until level with part horizontal louver and the vertical louver e VERTICAL AIR DIRECTION CONTROL HORIZONTAL AIR DIRECTION CONTROL The horizontal air direction is adjusted by horizontal louver forward or backward manually rotating the vertical louver right or left by Remote Controller How to Secure the Drain Pipe In humid weather excess water may cause the BASE PAN to overflow To drain the water remove the DRAIN CAP and secure the DRAIN PIPE to the rear hole of the BASE PAN Press the drain pipe into the hole by pushing down and away from the fins to avoid injury See Fig 1 Optional CW3H02502C Remove the rubber plug and slide the chassis out from the cabinet See Fig 2 Drain pipe Install the drain pan over the corner of the cabinet Drain cap Fig 1 where you removed the plug with 4 screws See Fig 3 3 Connect the drain hose to the outlet located at the bottom
29. r fire shock or fire due to heat due to heat generation e If the power cord is damaged it must generation be replaced by the manufacturer or an authorized service center or a similarly qualified person in order to avoid a hazard Do not modify power cord Do not operate with wet Do noi direct air flow at room length or share the outlet hands or in a damp occupants with other appliances environment e It will cause electric shock or fire e It will cause electric shock e This could damage your health due to heat generation g g S z CAUTION Do not clean the air Ventilate well when used When the air filter is to be removed do not touch the conditioner with water together with a stove etc metal parts of the unit e An oxygen shortage may occur 2 E 8 ES E E It may cause an injury Water may enter the unit and degrade the insulation It may cause an electric shock When the unit is to be Do not put a pet or house Do not use for special cleaned switch off and turn plant where it will be exposed purposes off the breaker to direct air flow e Since the fan rotates at high This could injure the pets or Do not use this air conditioner to preserve precision devices food pels plants and art objects t speed during operation it may plants cause an injury may cause deterioration of quality etc Do not put a heater etc where it is exposed to
30. sions and performance Remove the batteries from the remote controller if the air conditioner is not going to be used for an extended length of time 1 Remove the cover from the back of the remote controller 2 Insert two AAA dry cell batteries e Be sure that the and directions are correct e Be sure that both batteries are new 3 Re attach the cover Features Learning parts name prior to installation will help you understand the installation procedure Features HA VERTICAL AIR DEFLECTOR HORIZONTAL LOUVER HORIZONTAL AIR DEFLECTOR z a a VERTICAL LOUVER S CNN a e AIR DISCHARGE S CABINET SS SS FRONT GRILLE DS 5 e AIR FILTER AIR INTAKE Ss INLET GRILLE 3 Z BRACE COMPRESSOR Ae CONDENSER ee BASE PAN CONTROL BOARD REMOTE CONTROLLER POWER CORD Installation How to Install the Unit INSIDE FOAM lie ea E HEAT COOLED RADIATION AIR About 1 2 Over 20 1 To avoid vibration and noise make sure the unit is installed securely and firmly 2 Install the unit where the sunlight does not shine directly on the unit If the unit receives direct sunlight build an awning to shade the cabinet 3 There should be no obstacle like a fence within 20 which might restrict heat radiation from the condenser 4 To prevent reducing performance install the unit so that louvers of the cabinet are not blocked 5 Insta
31. terruptor de 20AMP Todo el cableado deber realizarse de acuerdo con los c digos y reglamentos el ctricos locales NOTA El cableado dom stico de aluminio podr a ocasionar problemas especiales Consulte a un electricista calificado E SEGURIDAD ELECTRICA NSTRUCCIONES DE CONEXION A TIERRA UNIDADES DE 230 208 y 230 208 VOLTIOS IMPORTANTES Estas unidades est n equipadas con una clavija de El aire acondicionado tiene una clavija de conexi n a tierra de tres patas en el cable de conexi n a tierra de tres patas en su cable de suministro de energ a que deber enchufarse en un suminstro de energ a que dever enchufarse en tomacorriente de pared para tres patas conectado a un tomacorriente de pared de tres paras tierra adecuadamente ver las ilustraciones a conectado a tierra adecuadamente para su continuaci n para su protecci n contra un posible protecci n contra un posible riesgo de riesgo de electrocuci n Si no tiene un tomacorriente electrocuci n con estas caracter sticas un electricista calificado dever instalar uno de acuerdo con el C digo El ctrico Nacional y los c digos y normas locales NOTA NO USE UN CABLE DE EXTENSION Antes de avisar al Servicio T cnico Tips para solucionar problemas Ahorre temopo y dinero Cuando tenga algun problema primero consulte el cuadro que se encuentra abajo y tal vez no necesite llamar para Solicitar servicio t cnico Operacion normal e Durar te dias lluviosos o c
32. trica o incendio a causa de la generaci n de calor miz Aseg rese de no hacerlo Aseg rese de seguir las instrucciones AN ADVERTENCIA No opere o pare la unidad insertando o tirando del enchufe Ello ocasionar a una descarga el ctrica o incendio a causa de la generaci n de calor No lo maneje con las manos humedas e Puede ocasionar una descarga el ctrica No da e o utilize un cable el ctrico inadecuado Ello ocasionar a una descarga el ctrica o incendio No exponga durante mucho tiempo la piel al aire frio procedente directamente del acondicionador Esto podr a da ar su salud a S 5 E Ss o oy E A 8 a 3 cs cs E 5 D R 2 PRECAUCION Cuando se vaya a quitar el No limpie el acondicionador Ventile bien cuando utilice el filtro de aire no toque las de aire con agua acondicionador junto con B partes met licas de la unidad una estufa etc S interior e Esto podria causar heridas El agua podr a entrar en la En este caso tal vez se produzca 3 unidad y degradar el aislamiento una falta de oxigeno Tambi n podria causar una sacudida el ctrica Is SA a AN z No lo utilice para prop sitos especiales Cuando limpie la unidad desconecte la alimentaci n y desconecte tambi n el disyuntor NO ponga un animal dom stico ni una planta donde quede directamente expuesto al flujo de a
33. uando la humedad es alta usted puede escuchar un ruido met llco causa do por agua recogida y arrojada contra el condensador Esta caracteristica ayuda a remover la humedad y mejorar la eficiencia e Usted puede escuchar que el relevo hace un click cuando se enciende o apaga el ciclo del comp esor e Durar te dias lluviosos o cuando la humedad es alta el agua ser recolectada on la base del aparato Esta agua podr fluir y ser eliminada por el lado externo de la unidad e El ventilador podr correr a n cuando el compresor no est encendido Operaci n anormal yn E El aire acondicionado est desconectado E El fusible est quemado el Aseg rese que ei aire acondicionado est conectado completamente a la fuente de energia e Cheque los fusibles interruptor de la casa y reemplace o El aire interruptor de energ a seha los fusibles o reestablezca el interruptor de energ a acondicionado no MUERO nn Lee enciende E Falta de energ a Cuando la energ a se reestablezca espere 3 minutos para encender de nuevo el aire acondicionado Con esto evitar que se produzca una sobrecarga en el compresor E El flujo de aire esta e Aseg rese que no haya cortinas persianas o muebles restringido bloqueando el frente del aire acondicionado E Coloque el control de Gire el control de TEMPERATURA a un n mero m s TEMPERATURA en un bajo n mero m s alto El aire IM El filtro de aire est sucio Limpie el filtro por lo me
34. ventana Ver Fig 3 Remueva el refuerzo de la Cinta de Espuma con 3 huecos y agr guelo en la parte inferior del tope de la barra de Retencion Superior Ver Fig 3 a Sujete la barra de retenci n superior al lado superior del gabinete con los 3 torni Ver Fig 4 BARRA DE RETENCION SUPERIOR Oo Inserte los paneles guias en la barra de retencion superior y en la guia marco del aire acondicionado Ver Fig 4 Cinta de Espuma Fig 3 7 Sujete las cortinas de la unidad con tornillos BARRA DE RETENCION SUPERIOR Tipo A Ver Fig 4 BE eae at SFA TIPO A Instalacion del Gabinete 1 Abra la ventana Marque una linea en el centro de la repisa de la ventana entre las molduras de tope de la ventana lateral Coloque sin apretar la m nsula del alf izar en la m nsula de soporte utilizando el pemo y la tuerca de segutidad Ver Fig 5 Coloque la m nsula del alf izar en el alf izar de la ventana utilizando los tornillos Tipo B Apriete el perno y la tuerca de seguridad Repisa de la ventana y alinee la marca central en el frente del fondo con la linea central marcada en la repisa de la ventana Ver Fig 6 Utilizando el tornillo M y la tuerca de seguridad coloque la m nsula de soporte en el orificio de la guia del gabinete Use el primer orificio de la guia despu s de la m nsula del alf zar en el borde exterior del alf izar de la ventana Ver Fig 6 Apri
Download Pdf Manuals
Related Search
Related Contents
deluxe cherry pitter operating manual Siemens 300 H Telephone User Manual 平成26年度前期実践広報セミナー Fujitsu Siemens Celsius M410 PC Desktop V7 Replacement Battery for selected Dell Notebooks Istruzioni per l'uso User Manual UMADM5X07-PV1-2EN Standard Design Device Certification Guide INSTALLATION - Produits Neptune Frigidaire 2020264A0429 User's Manual Copyright © All rights reserved.