1. 1 Lift the lever on the CPU socket Lift the lever completely or you will damage the CPU socket when Socket lever power is applied Install a proces sor into CPU 1 socket first 2 Install the CPU in the socket Make sure that pin 1 of the CPU is seated on pin 1 of the socket both corners are marked with a triangle When using only one CPU install it into CPU socket 1 CPU socket 2 is automatically disabled if only one CPU is used 3 Press the lever down until you hear it click into the locked posi tion See Figure 5 1 for pictures of Socket lever in the 604 pin CPU socket before and locked position after the processor is installed Chapter 5 Advanced Serverboard Setup 4 Place the heatsink directly on the CPU so that the four mounting holes are aligned with those on the chassis Make sure the heatsink sits completely flat on the CPU if not completely flat the space between the two will degrade the heat dissipation function of the heatsink which may cause the processor to overheat 5 Screw in two diagonal screws 1 and 2 or 3 and 4 until just snug do not fully tighten then do the same with the remaining two diagonal screws Finish by fully tightening all four screws see Figure 5 2 6 If installing two processors repeat these steps to install the second processor in the CPU 2 slot Figure 5 1 604 pin PGA Socket Empty and with Processor Installed
2. Figure 6 3 Removing the Front Bezel 1 Unlock 2 Press release knob 3 Remove bezel assembly Accessing the Drive Bays SCSI Drives Because of their hotswap capability you do not need to access the inside of the chassis or power down the system to install or replace SCSI drives Proceed to the next step for instructions CD ROM Floppy Disk Drives For installing removing a CD ROM or floppy disk drive you will need to gain access to the inside of the 6013P 8 by removing the top cover of the chassis Proceed to the CD ROM and Floppy Drive Installation section later in this chapter for instructions Note Only a slim CD ROM drive will fit into the 6013P 8 SUPERSERVER 6013P 8 Manual SCSI Drive Installation 1 Mounting a SCSI drive in a drive carrier The SCSI drives are mounted in drive carriers to simplify their installation and removal from the chassis These carriers also help promote proper airflow for the SCSI drive bays For this reason even empty carriers without SCSI drives installed must remain in the chassis To add a new SCSI drive install a drive into the carrier with the printed circuit board side toward the carrier so that the mounting holes align with those in the carrier Secure the drive to the carrier with four screws as shown in Figure 6 4 Figure 6
3. Floppy Connector The floppy connector is located on JP7 See the table below for pin definitions Floppy Connector Pin Definitions JP7 Pin Number Function Pin Number Function 1 GND 2 FDHDIN 3 GND 4 Reserved 5 Key 6 FDEDIN 4 GND 8 Index 9 GND 10 Motor Enable 11 GND 12 Drive Select B 13 GND 14 Drive Select A 15 GND 16 Motor Enable 17 GND 18 DIR 19 GND 20 STEP 21 GND 22 Write Data 23 GND 24 Write Gate 25 GND 26 Track 00 27 GND 28 Write Protect 29 GND 30 Read Data 31 GND 32 Side 1 Select 33 GND 34 Diskette 5 22 Chapter 5 Advanced Serverboard Setup IDE Connectors There are no jumpers to configure the onboard IDE 1 and 2 connectors See the table on the right for pin definitions Ultra320 SCSI Connectors Refer to the table on the right for the pin defi nitions of the Ultra320 SCSI connectors lo cated at JA1 and JA2 IDE Connector Pin Definitions J2A J3A Pin Number Function Pin Number Function 1 Reset IDE 2 GND 3 Host Data 7 4 Host Data 8 5 Host Data 6 6 Host Data 9 7 Host Data 5 8 Host Data 10 9 Host Data 4 10 Host Data 11 11 Host Data 3 12 Host Data 12 13 Host Data 2 14 Host Data 13 15 Host Data 1 16 Host Data 14 17 Host Data 0 18 Host Data 15 19 GND 20 Key 21 DRQ3 22 GND 23 I O Write 24 GND 25 l O Read 26 GND 27 IOCHRDY 28 BALE 29 DACK3 30 GND 31 IRQ14 32 IOCS16 33 Addr 1 34 GND 35 Addr 0 36 Addr 2 37 Chip Select 0 38 Chip Select 1
4. 42 5 reines CMOS CIGar itte ta er EE EE ERES RICOH SERERE GEAN Ena ble Disable anre i epe eee MGA Enable Disable 5 mte iiit erede Front Side Bus Speed eese tro Perte SGSI Enable Bisable e etti eec mro irs SCSI Termination Enable Disable Watch Dog Enable Disable sssseeeenns 5 10 Onboard Indicators rini terere mee eee GLANT GLAN ILE DS ttn top eene en t Eee rte cobi edes 5 11 Floppy Hard Drive and SCSI Connections ssees 5 22 Floppy GOMMOCIO Me o aoreet eer ett eiae 5 22 IDE COnM CtOrs once itr ene ri a eid E 5 23 Ultra320 SGSI GOBHectors c ei retener etes 5 23 5 12 Installing Software Drivers drei e e eiectus 5 24 Chapter 6 Advanced Chassis Setup 6 1 Static Sensitive Devices eec ie etis mes Eee deeds e ERERA TERR 6 2 Cntr PANEN enit rent ivan aa ete i get 6 3 SystemtlE allSun seri rra er bod erro iet aee i eo dete eve vegan dE Pedo System Fan Palluretizcs canis avian A R AE Replacing System Cooling Fans eee 6 4 Drive Bay Installation Removal nece Removing the Front Bezel eeeeeeeeeeeenee nennen nnns Accessing the Drive Bays trennen neun SCSI Drive Installation CD ROM and Floppy Drive Installation 6 5 JPOWOISUDDIV eese orit ne ibunt ei ni ALI ALT OR Power S pply FailUte n cir err rrt Removing Replacing the Power Supply viii Table of Co
5. installing the CPU If the lever is only partly raised damage to the socket or CPU may result Warning Make sure you lift the lever completely when SUPERSERVER 6013P 8 User s Manual 4 Screw 1 Screw WZ Do not reuse thermal grease 2 Screw 3 Screw Figure 5 2 Heatsink Installation 5 4 Chapter 5 Advanced Serverboard Setup 5 3 Connecting Cables Now that the processors are installed the next step is to connect the cables to the serverboard These include the data ribbon cables for the peripherals and control panel and the power cables Connecting Data Cables The ribbon cables used to transfer data from the peripheral devices have been carefully routed in preconfigured systems to prevent them from block ing the flow of cooling air that moves through the system from front to back If you need to disconnect any of these cables you should take care to keep them routed as they were originally after reconnecting them make sure the red wires connect to the pin 1 locations If you are configuring the sys tem keep the airflow in mind when routing the cables The following data cables with their serverboard connector locations noted should be con nected See the serverboard layou
6. 39 Activity 40 GND 68 pin Ultra320 SCSI Connectors JA1 JA2 Connector Connector Contact Contact Number Signal Names Number Signal Names 1 DB 12 35 DB 12 2 DB 13 36 DB 13 3 DB 14 37 DB 14 4 DB 15 38 DB 15 5 DB P1 39 DB P1 6 DB 0 40 DB 0 7 DB 1 41 DB 1 8 DB 2 42 DB 2 9 DB 3 43 DB 3 10 DB 4 44 DB 4 11 DB 5 45 DB 5 12 DB 6 46 DB 6 13 DB 7 47 DB 7 14 DB P 48 DB P 15 GROUND 49 GROUND 16 DIFFSENS 50 GROUND 17 TERMPWR 51 TERMPWR 18 TERMPWR 52 TERMPWR 19 RESERVED 53 RESERVED 20 GROUND 54 GROUND 21 ATN 55 ATN 22 GROUND 56 GROUND 23 BSY 57 BSY 24 ACK 58 ACK 25 RST 59 RST 26 MSG 60 MSG 27 SEL 61 SEL 28 C D 62 C D 29 REQ 63 REQ 30 l1 O 64 1 0 31 DB 8 65 DB 8 32 DB 9 66 DB 9 33 DB 10 67 DB 10 34 DB 11 68 DB 11 5 23 SUPERSERVER 6013P 8 User s Manual 5 12 Installing Software Drivers After all the hardware has been installed you must install the software drivers The necessary drivers are all included on the Supermicro CD that came packaged with your serverboard After inserting this CD into your CD ROM drive the display shown in Figure 5 8 should appear If this display does not appear double click on the My Computer icon and then on the icon representing your CD ROM drive Finally double click on the S Setup icon SUPERMICRO XS5DES serser board Drivers Bc Too Cn Dod z a
7. Installing a new power supply Replace the failed unit with another unit of the same input voltage output voltage and wattage It is highly recommended to replace it with exactly the same model power supply Carefully insert the new unit into position to plug it into the power distribution board making sure you are not holding it at too great an angle which may damage the power distribution board Push it completely into the power distribution board and seat it in the chassis When correctly installed it should be laying flat make sure the end of the power supply is not sitting on the stop in the chassis Reconnect the power cord replace the chassis top cover and reposition the unit back into the rack Finish by depressing the power button on the chassis front control panel SUPERSERVER 6013P 8 Manual Removing Replacing the Power Supply Figure 6 6 with optional front bezel shown 6 10 Chapter 7 BIOS Chapter 7 BIOS 7 1 Introduction This chapter describes the PhoenixBIOS Setup utility for the XSDPR 8G2 The Phoenix ROM BIOS is stored in a flash chip and can be easily upgraded using a floppy disk based program Note Due to periodic changes to the BIOS some settings may have been added or deleted and might not yet be recorded in this manual Please refer to the Manual Download area of the Supermicro web site lt http www supermicro com gt for any changes to BIOS that may not be reflected in this m
8. located under the blower fan and beneath the frame cross section that separates the drive bay area from the motherboard area of the chassis aE NIC2 e NIC2 Indicates network activity on GLAN2 when flashing AA NIC1 e NIC1 Indicates network activity on GLAN1 when flashing a e HDD Indicates IDE channel activity On the SuperServer 6013P 8 this light indicates SCSI and CD ROM drive activity when flashing Chapter 3 System Interface e Power Indicates power is being supplied to the system s power supply units This LED should normally be illuminated when the system is operating 3 4 SCSI Drive Carrier LEDs Each SCSI drive carrier has two LEDs e Green When illuminated the green LED on the front of a SCSI drive carrier indicates drive activity A connection to the SCSI SCA backplane enables this LED to blink on and off when that particular drive is being accessed e Red A SAF TE compliant backplane standard on the 6013P 8 activates the red LED which indicates a drive failure If one of the SCSI drives fail you should be notified by your system management software Please refer to Chap ter 6 for instructions on replacing failed SCSI drives SUPERSERVER 6013P 8 User s Manual Notes Chapter 4 System Safety 4 1 Chapter 4 System Safety Electrical Safety Precautions A Basic electrical safety precautions should be followed to protect yourself from harm and the SuperServer 601
9. FAN BANK 3 DIMM 3B JF2 CPU2 Chassis FAN CPU2 MCH upss GLANI PCDXEZ Jp7 r PCIX SB NED GLAN2 gt g g SMB aia e Zero Channel RAID Socket C gele z COPA P64H2 IPMI VGA lt E m o o 0 vat I Rage XL pas a a 2 E ichs BATTERY 3 E g r AIC 7902 BIOS ts 5 mE Speaker JD4 jp22 O p JA2 ooo CHS woR woL COM2 FAN3 SUPERO X5DPR 8G2 m EO gt FPUSBO 1 SLP JBT1 WD IR CIR USB2 PWRLED Speaker JL1 Notes The IPMI socket is an optional feature Jumpers not noted are for test purposes only 5 10 Chapter 5 Advanced Serverboard Setup X5DPR 8G2 Quick Reference Jumper Description Default Setting JBT1 CMOS Clear See Jumper Section JD1 Speaker Enable Pins 6 7 Closed Enabled JPA1 JPA2 SCSI Channel A B Termination Open Terminated JD4 GLAN1 GLAN2 Enable Disable Pins 1 2 Enabled JP4 VGA Enable Disable Pins 1 2 Enabled JP9 Power Fail Alarm En Disable Open Disabled JP22 SCSI Enable Disable Pins 1 2 Enabled JP37 WD Watch Dog Enable Disable Open Disabled JP38 Front Side Bus Speed Pins 1 2 Auto Connector Description ATX POWER Primary ATX Power Connector COM1 COM2 COM1 COM2 Serial Port Connector CPU1 CPU2 CPU 1 and CPU2 Sockets CPU CHS FAN CPU 1 amp 2 Chassis Fan Headers DIMM 1A DIMM 3B Memory RAM Slots IDE 1 IDE 2 IDE 1 2 Hard Disk Drive Connectors JA1 LVD SCSI CH A Connector JA2 LVD SCSI CH B Connector JD1 JBT1 WD IR CIR USB2 PWRLED SPKR JF2 Front Control Panel Connector JP7 Fl
10. Ground NMI X X Power LED Vcc HDD LED Vcc NIC1 LED Vcc NIC2 LED Vcc Overheat LED Vcc Power Fail LED Vcc Ground Reset gt Reset Button Ground Pwr Power Button Chapter 5 Advanced Serverboard Setup 5 4 I O Ports The I O ports are color coded in conformance with the PC 99 specification See Figure 5 4 below for the colors and locations of the various I O ports Figure 5 4 Rear Panel I O Ports p oS OG GE Keyboard Mouse USBO USB1 COM Port LAN1 LAN2 VGA Graphics External SCSI Purple Green Ports Turquoise Gb Gb Port Blue Port Port 5 5 Installing Memory Note Check the Supermicro web site for recommended memory modules http www supermicro com TECHSUPPORT FAQs Memory_vendors htm CAUTION Exercise extreme care when installing or removing DIMM modules to prevent any possible damage Also note that the memory is interleaved to improve performance see step 1 DIMM Installation See Figure 5 5 1 Insert the desired number of DIMMs into the memory slots starting with Bank 1 DIMM 1A DIMM 1B The memory scheme is interleaved so you must install two modules at_a time beginning with Bank 1 then Bank 2 and so on The 6013P 8 requires the use of low profile memory 2 Insert each DIMM module into its slot Pay attention to the notch along the bottom of the module to prevent inserting the DIMM module incorrectly 3 Gently press do
11. IRQ4 Serial Port B This setting allows you to assign control of serial port B The options are Enabled user defined Disabled Auto BIOS controlled and OS Controlled Mode Specify the type of device that will be connected to serial port B Options are Normal and IR for an infrared device Base I O Address Select the base I O address for serial port B The options are 3F8 2F8 3E8 and 2E8 Interrupt Select the IRQ interrupt request for serial port B Options are IRQ3 and IRQ4 Parallel Port This setting allows you to assign control of the parallel port The options are Enabled user defined Disabled and Auto BIOS controlled Base I O Address Select the base I O address for the parallel port The options are 378 278 and 3BC Interrupt Select the IRQ interrupt request for the parallel port Options are IRQ5 and IRQ7 Chapter 7 BIOS Mode Specify the parallel port mode Options are Output Only Bi directional EPP and ECP DMA Channel Specify the DMA channel Options are DMA1 and DMA3 Floppy Disk Controller This setting allows you to assign control of the floppy disk controller The options are Enabled user defined Disabled and Auto BIOS controlled Base I O Address Select the base I O address for the parallel port The options are Primary and Secondary Large Disk Access Mode This setting determines how large hard drives are to be accessed The options are DOS or
12. In single rack installation stabilizers should be attached to the rack In multiple rack installations the racks should be coupled together Always make sure the rack is stable before extending a component from the rack You should extend only one component at a time extending two or more simultaneously may cause the rack to become unstable Server Precautions Review the electrical and general safety precautions in Chapter 4 Determine the placement of each component in the rack before you install the rails Install the heaviest server components on the bottom of the rack first and then work up Use a regulating uninterruptible power supply UPS to protect the server from power surges voltage spikes and to keep your system operating in case of a power failure Allow the hot plug SCSI drives and power supply units to cool before touching them Always keep the rack s front door and all panels and components on the servers closed when not servicing to maintain proper cooling 2 2 Chapter 2 Server Installation 2 4 Installing the SuperServer 6013P 8 into a Rack This section provides information on installing the SuperServer 6013P 8 into a rack unit with the rack rails provided If the 6013P 8 has already been mounted into a rack you can skip ahead to Sections 2 5 and 2 6 There are a variety of rack units on the market which may mean the assembly procedure will differ slightly You should also refe
13. Other for Unix Novellle NetWare and other operating systems Local Bus IDE Adapter Use this setting to enable the integrated local bus IDE adapter Options are Disable Primary Secondary and Both gt Advanced Chipset Control Access the submenu to make changes to the following settings Enable Memory Gap This setting allows you to turn off system RAM to free up address space The options for this setting are Disabled and Extended 7 9 SUPERSERVER 6013P 8 Manual ECC Configuration This setting lets you enable or disable ECC Error Correction and Checking The options are ECC and Disabled ECC Error Type This setting lets you select which type of interrupt will be activated as a result of an ECC error The options are None NMI Non Maskable Interrupt SMI System Management Interrupt and SCI System Control Interrupt SERR Signal Condition This setting specifies the conditions required to qualify as an ECC error Options are None Single Bit Multiple Bit and Both gt Advanced Processor Options Access the submenu to make changes to the following settings CPU Speed This is a display that indicates the speed of the installed processor Frequency Ratio This setting allows you to specify the value of tthe internal frequency multiplier of the processor which is used to determine the processor speed Options are x8 x16 x17 x18 x19 and x20 Fast String Operations This setting allows you
14. Ultra320 onboard SCSI SCSI SCA Backplane Controller QLogic GEM318 controller for SAF TE compliance SCSI Drive Bays Four 4 drive bays to house four 4 standard 1 80 pin SCA SCSI drives SUPERSERVER 6013P 8 User s Manual Peripheral Drive Bays One 1 3 5 slim floppy drive One 1 slim CD ROM drive Four 4 3 5 x 1 drive bays for SCSI drives Expansion Slots provided with butterfly riser card One 1 64 bit 183 MHz standard PCI slot and one 1 64 bit 66 MHz low profile PCI slot Motherboard Model XSDPR 8G2 Extended ATX form factor Dimensions 12 x 13 in 305 x 330 mm Chassis Model SC813S 500 Form Factor 1U rackmount Dimensions WxHxD 17 2 x 1 7 x 25 6 in 437 x 44 x 650 mm Weight Net Bare Bone 32 Ibs 14 5 kg Gross Bare Bone 42 Ibs 19 1 kg System Cooling Two 2 10 cm blower fans System Input Requirements AC Input Voltage 100 240V AC auto range Rated Input Current 10A 115V to 5A 230V Rated Input Frequency 50 to 60 Hz Power Supply Rated Output Power 500W Model SP502 1S Part PWS 0048 Rated Output Voltages 3 3V 20A 5V 20A 12V 36A 12V 1A 5Vsb 2A BTU Rating 2750 BTUs hr for rated output power of 500W Appendix C System Specifications Operating Environment Operating Temperature 0 to 35 degrees C Non operating Temperature 35 to 60 degrees C Operating Relative Humidity 5 to 90 non condensing Non operating Relative Humidity 5
15. alternate registers with initial POST values 12h Restore CPU control word during warm boot 13h Initialize PCI Bus Mastering devices 14h Initialize keyboard controller 16h 1 2 2 3 BIOS ROM checksum B 1 SUPERSERVER 6013P 8 Manual POST Code 17h 18h 1Ah 1Ch 20h 22h 24h 28h 29h 2Ah 2Ch 2Eh 2Fh 32h 33h 36h 38h 3Ah 3Ch 3Dh 4th 42h 45h 46h 47h 48h 49h 4Ah 4Bh 4Ch 4Eh 4Fh 50h 51h 52h 54h 55h 58h 59h 5Ah 5Bh Description Initialize cache before memory Auto size 8254 timer initialization 8237 DMA controller initialization Reset Programmable Interrupt Controller 1 8 1 1 Test DRAM refresh 1 3 1 3 Test 8742 Keyboard Controller Set ES segment register to 4 GB Auto size DRAM Initialize POST Memory Manager Clear 512 kB base RAM 1 3 4 1 RAM failure on address line xxxx 1 3 4 3 RAM failure on data bits xxxx of low byte of memory bus Enable cache before system BIOS shadow Test CPU bus clock frequency Initialize Phoenix Dispatch Manager Warm start shut down Shadow system BIOS ROM Auto size cache Advanced configuration of chipset registers Load alternate registers with CMOS values Initialize extended memory for RomPilot Initialize interrupt vectors POST device initialization 2 1 2 3 Check ROM copyright notice Initialize 120 support Check video configuration against CMOS Initialize PCI bus and devices Initialize all video adapters in system QuietBoot start optional Shadow video B
16. into a RACK eee eee sss 2 3 Identifying the Sections of the Rack Rails sssesess 2 3 installing the Inner Rails censo rette b et hen iden 2 3 Installing the Quter Rails ntn rt tert 2 4 Installing the Server into the Rack seeeeee 2 5 Installing the Server into a Telco Rack sse 2 6 2 5 Checking the Serverboard Setup ssssseeeme 2 7 2 6 Checking the Drive Bay Setup Chapter 3 System Interface asl SOVOLVIGW id cur cent eicere thn ss eni er tnbus Er IT IM eich i Al teer ELI 3 1 3 2 Control Panel B lttOns cnni eere RERO obi 3 1 3 3 vi Table of Contents 3 4 SCSI Drive Gantien WEDS siropi a EE a te ttes 3 3 Chapter 4 System Safety 4 1 4 2 4 3 4 4 Electrical Safety Precautions crees 4 1 General Safety Precautlons ic o e tt ea 4 2 ESD Precautions sss era anA A enn 4 3 Operating Precautions er tdem s 4 4 Chapter 5 Advanced Serverboard Setup 5 1 5 2 5 3 5 4 5 5 5 6 5 7 5 8 Handling the XSDPR 8G2 Serverboard sss 5 1 PGA Processor and Heatsink Installation eeeeene 5 2 Connecting Cables endo EEEa ies 5 5 Gonnecting Data Cables ssiri eaea i 5 5 Connecting Power Cables cceecceceeseeseeneeeeeeeceseeseeeseeeeseeeeeeeaeeeeneeneeees 5 5 Connecting the Control Panel 5 6 Heu c S
17. must be plugged into grounded electrical outlets Serverboard Battery CAUTION There is a danger of explosion if the onboard battery is installed upside down which will reverse its polarities On the XSDPR 8G2 the positive side should be facing up This battery must be replaced only with the same or an equivalent type recommended by the manufacturer Dispose of used batteries according to the manufacturer s instructions CD ROM Laser CAUTION this server may have come equipped with a CD ROM drive To prevent direct exposure to the laser beam and hazardous radiation exposure do not open the enclosure or use the unit in any unconventional way 4 2 General Safety Precautions A Follow these rules to ensure general safety Keep the area around the SuperServer 6013P 8 clean and free of clutter The SuperServer 6013P 8 weighs approximately 39 Ibs 17 7 kg when fully loaded When lifting the system two people at either end should lift slowly with their feet spread out to distribute the weight Always keep your back straight and lift with your legs Place the chassis top cover and any system components that have been removed away from the system or on a table so that they won t accidentally be stepped on While working on the system do not wear loose clothing such as neckties and unbuttoned shirt sleeves which can come into contact with electrical circuits or be pulled into a cooling fan Remove any jewel
18. to 95 non condensing Regulatory Compliance Electromagnetic Emissions FCC Class B EN 55022 Class B EN 61000 3 2 amp EN 61000 3 3 CISPR 22 Class B Electromagnetic Immunity EN 55024 CISPR 24 EN 61000 4 2 EN 61000 4 3 EN 61000 4 4 EN 61000 4 5 EN 61000 4 6 EN 61000 4 8 EN 61000 4 11 Safety EN 60950 IEC 60950 Compliant UL Listed USA CUL Listed Canada TUV Certified Germany CE Marking Europe SUPERSERVER 6013P 8 User s Manual Notes
19. to Enable or Disable fast string operations Compatible FPU Code This setting allows you to Enable or Disable the compatible FPU code 7 10 Chapter 7 BIOS Split Lock Operations This setting allows you to Enable or Disable split lock operations Hyper threading This setting allows you to Enable or Disable hyper threading Enabling hyper threading results in increased CPU performance L3 Cache This setting allows you to Enable or Disable the L3 cache gt DMI Event Logging Access the submenu to make changes to the following settings Event Log Validity This is a display not a setting informing you of the event log validity Event Log Capacity This is a display not a setting informing you of the event log capacity View DMI Event Log Highlight this item and press lt Enter gt to view the contents of the event log Event Logging This setting allows you to Enable or Disable event logging Event Logging This setting allows you to Enable or Disable ECC event logging Mark DMI Events as Read Highlight this item and press lt Enter gt to mark the DMI events as read 7 11 SUPERSERVER 6013P 8 Manual Clear All DMI Event Logs Highlight this item and press lt Enter gt to clear all DMI event logs gt Console Redirection Access the submenu to make changes to the following settings COM Port Address Specifies to redirect the console to On board COMA or On board COMB This setting can a
20. 131 U S A 1 408 503 8000 1 408 503 8008 marketing supermicro com General Information support supermicro com Technical Support WWW Supermicro com SuperMicro Computer B V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands 31 0 73 6400390 31 0 73 6416525 sales supermicro nl General Information support supermicro nl Technical Support rma supermicro nl Customer Support SuperMicro Taiwan D5 4F No 16 Chien Ba Road Chung Ho 235 Taipei Hsien Taiwan R O C 886 2 8226 3990 886 2 8226 3991 www supermicro com tw Technical Support Email Tel support supermicro com tw 886 2 8228 1366 ext 132 or 139 SUPERSERVER 6013P 8 Manual Notes Chapter 2 Server Installation Chapter 2 Server Installation 2 1 Overview This chapter provides a quick setup checklist to get your SuperServer 6013P 8 up and running Following these steps in the order given should enable you to have the system operational within a minimum amount of time This quick setup assumes that your SuperServer 6013P 8 system has come to you with the processors and memory preinstalled If your system is not already fully inte grated with a serverboard processors system memory etc please turn to the chapter or section noted in each step for details on installing specific compo nents 2 2 Unpacking the SuperServer 6013P 8 You should inspect the box the SuperServer 6013P 8 was shipped in
21. 2E or 30 base 512K RAM error it displays an additional word bitmap xxxx indicating the address line or bits that failed For example 2C 0002 means address line 1 bit one set has failed 2E 1020 means data bits 12 and 5 bits 12 and 5 set have failed in the lower 16 bits The BIOS also sends the bitmap to the port 80 LED display It first displays the checkpoint code followed by a delay the high order byte another delay and then the loworder byte of the error It repeats this sequence continuously SUPERSERVER 6013P 8 Manual Notes Appendix C System Specifications Appendix C System Specifications Processors Single or dual Intel Xeon 604 or 603 pin processors of up to 3 20 GHz at a front side system bus speed of 533 400 MHz Note Please refer to the support section of our web site for a complete listing of supported processors http www supermicro com TechSupport htm Chipset Intel E7501 chipset BIOS 4 Mb Phoenix Flash ROM Memory Capacity Six 184 pin DDR DIMM sockets supporting up to 12 GB of low profile registered ECC DDR266 200 PC2100 1600 SDRAM Note Interleaved memory requires memory to be installed two at a time Memory speed is dependant on processor front side bus speed See the memory section in Chapter 5 for details Operating Systems Supported Windows NT Windows 2000 Solaris Netware SCO UNIX and Linux SCSI Controller Adaptec AIC 7902 for dual channnel
22. 3P 8 from damage Be aware of the locations of the power on off switch on the chassis as well as the room s emergency power off switch disconnection switch or electrical outlet If an electrical accident occurs you can then quickly remove power from the system Do not work alone when working with high voltage components Power should always be disconnected from the system when removing or installing main system components such as the serverboard memory modules and the CD ROM and floppy drives not necessary for SCSI drives When disconnecting power you should first power down the system with the operating system and then unplug the power cords of all the power supply units in the system When working around exposed electrical circuits another person who is familiar with the power off controls should be nearby to switch off the power if necessary Use only one hand when working with powered on electrical equipment This is to avoid making a complete circuit which will cause electrical shock Use extreme caution when using metal tools which can easily damage any electrical components or circuit boards they come into contact with Do not use mats designed to decrease electrostatic discharge as protection from electrical shock Instead use rubber mats that have been specifically designed as electrical insulators 4 1 SUPERSERVER 6013P 8 Manual The power supply power cord must include a grounding plug and
23. 4 Mounting a SCSI Drive in a Carrier Use caution when working around the SCSI backplane Do ZN not touch the backplane with any metal objects and make sure no ribbon cables touch the backplane or obstruct the holes which aid in proper airflow Important Regardless of how many SCSI hard drives are AN installed all SCSI drive carriers must remain in the drive bays for proper airflow Chapter 6 Advanced Chassis Setup 2 Installing removing hot swap SCSI drives The SCSI drive bays are located in the front of the chassis making them easily accessible for installation and removal The SCSI drives are hot swap units meaning that they can be installed and removed while the system is running To remove a SCSI drive first push the colored release button located beside the drive s LEDs then swing the handle fully out and use it to pull the SCSI drive carrier straight out see Figure 6 5 Figure 6 5 Removing SCSI Drives Important All of the SCSI drive carriers must remain in the drive bays to maintain proper cooling airflow 6 7 SUPERSERVER 6013P 8 Manual CD ROM and Floppy Drive Installation The top cover of the chassis must be opened to gain full access to the CD ROM and floppy drive bays The 6013P 8 accomodates only slim CD ROM drives Side mounting brackets are needed to mount a slim CD ROM drive in the 6013P 8 server You must power down the system before installing or removing a floppy or CD RO
24. 5 7 Installing MOTIOLy seite tne YD CREE EXER OX Cena rk in CO EFE EODD EOD 5 7 Adding POl Cards acr ttt eet Url eee de ftris 5 9 Serverboard Details innt etr etta ro iEn 5 10 X5DPR 8G2 E8yOUL iai cete eid tnt ere danken ai dca Vea 5 10 X5DPR 8G2 Quick Reference siaren eira 5 11 Connector Definitions sss emen ATX Power Connection PWR SEC Connection NMI Button iacere deeds dai ii reddet Power EBD Serrat cares rss cutee EAM pre ee coveeede Acces Ai cekias HDD LED ioa erre niiatea ERES NIGH ME io NIG2 WED cte rm rete dv reri esee d Overheat LED sssssssssssssessseeeeeeee tnnt nennen nnne nnne nnns Power Fail BED eir triti retener eter te Ee SNEEN GENS M H Power Button Universal Serial BUS eio otro p reo E Per n rtt Extra USB Headers scio ANES Serial POMS asics schssescshcesscad ccsacs cheaseduveetesavecress Erreur MEER ERE E UE E MARE devas ATX PS 2 Keyboard amp Mouse Ports late Headers oe eite gei iecore exiit tee Ee eR apara taaie aiaa GLAN 1 2 Ethernet Ports onere ite Power LED Speaket NMI itr tir ri ner Es SUPERSERVER 6013P 8 Manual Third Power Supply Fail Header ner IAEA SI OM cco cet cox coy Wake On LAN citet rai E e rr erre te OE ERES Wake On Ring KOylOCK q 5 9 Jumper Settings enne enne Explanation of Jumpers
25. AVE LIABILITY FOR ANY HARDWARE SOFTWARE OR DATA STORED OR USED WITH THE PRODUCT INCLUDING THE COSTS OF REPAIRING REPLACING INTEGRATING INSTALLING OR RECOVERING SUCH HARDWARE SOFTWARE OR DATA Any disputes arising between manufacturer and customer shall be governed by the laws of Santa Clara County in the State of California USA The State of California County of Santa Clara shall be the exclusive venue for the resolution of any such disputes Supermicro s total liability for all claims will not exceed the price paid for the hardware product Unless you request and receive written permission from SUPER MICRO COMPUTER you may not copy any part of this document Information in this document is subject to change without notice Other products and companies referred to herein are trademarks or registered trademarks of their respective companies or mark holders Copyright 2003 by SUPER MICRO COMPUTER INC All rights reserved Printed in the United States of America Preface Preface About This Manual This manual is written for professional system integrators and PC technicians It provides information for the installation and use of the SuperServer 6013P 8 Installation and maintainance should be performed by experienced technicians only The SuperServer 6013P 8 is a high end dual Xeon processor 1U rackmount server based on the SC813S 1U rackmount server chassis and the XSDPR 8G2 serverboard which supports single o
26. IOS ROM Display BIOS copyright notice Initialize MultiBoot Display CPU type and speed Initialize EISA board Test keyboard Set key click if enabled Enable USB devices 2 2 3 1 Test for unexpected interrupts Initialize POST display service Display prompt Press F2 to enter SETUP Disable CPU cache B 2 Appendix B BIOS POST Codes POST Code 5Ch 60h 62h 64h 66h 67h 68h 69h 6Ah 6Bh 6Ch 6Eh 70h 72h 76h 7Ch 7Dh 7Eh 80h 81h 82h 83h 84h 85h 86h 87h 88h 89h 8Ah 8Bh 8Ch 8Fh 90h 91h 92h 93h 95h 96h 97h 98h Description Test RAM between 512 and 640 kB Test extended memory Test extended memory address lines Jump to UserPatch1 Configure advanced cache registers Initialize Multi Processor APIC Enable external and CPU caches Setup System Management Mode SMM area Display external L2 cache size Load custom defaults optional Display shadow area message Display possible high address for UMB recovery Display error messages Check for configuration errors Check for keyboard errors Set up hardware interrupt vectors Initialize Intelligent System Monitoring Initialize coprocessor if present Disable onboard Super I O ports and IRQs Late POST device initialization Detect and install external RS232 ports Configure non MCD IDE controllers Detect and install external parallel ports Initialize PC compatible PnP ISA devices Re initialize onboard I O ports Configure Motherboard Configura
27. M drive First release the retention screws that secure the server unit to the rack Grasp the two handles on either side and pull the unit straight out until it locks you will hear a click Next depress the two buttons on the top of the chassis to release the top cover and at the same time push the cover away from you until it stops You can then lift the top cover from the chassis to gain full access to the inside of the server With the chassis cover removed unplug the power and data cables from the drive you want to remove Then locate the locking tab at the rear of the drive It will be on the left side of the drive when viewed from the front of the chassis Pull the tab away from the drive and push the drive unit out the front of the chassis Add a new drive by following this procedure in reverse order You may hear a faint click of the locking tab when the drive is fully inserted Remember to reconnect the data and power cables to the drive before replacing the chassis cover and restoring power to the system Please be aware of the following The floppy disk drive cable has seven twisted wires A color mark on a cable typically designates the location of pin 1 A single floppy disk drive ribbon cable has 34 wires and two connectors to provide for two floppy disk drives The connector with twisted wires always connects to drive A and the connector that does not have twisted wires always connects to drive B Chapter 6 Adva
28. Mode 4 and Mode 5 System Memory This display informs you how much system memory is recognized as being present in the system Extended Memory SUPERSERVER 6013P 8 Manual 7 4 Advanced Setup Choose Advanced from the Phoenix BIOS Setup Utility main menu with the arrow keys You should see the following display The items with a triangle beside them have sub menus that can be accessed by highlighting the item and pressing lt Enter gt Options for PIR settings are displayed by highlighting the setting option using the arrow keys and pressing lt Enter gt All Advanced BIOS Setup options are described in this section Phoenix BIOS Setup Utility Main Advanced Installed OS Quick Boot Mode Quiet Boot Legacy USB Support Reset Configuration Data Cache Memory gt I O Device Configuration Large Disk Access Mode Local Bus IDE Adapter Advanced Chipset Control Advanced Processor Options gt gt DMI Event Logging gt Console Redirection F1 Help Ti Esc Exit e Select Item Select Menu Installed OS Security Power Boot Exit Item Specific Help Win95 Enabled Disabled Enabled No Change Values Enter Select gt Sub Menu F9 Setup Defaults F10 Save and Exit This setting allows you to choose which operating system you are using to run the system Options are Other Win95 Win98 WinMe and Win2000 Quick Boot Mode If enabled this feature will speed up the POS
29. On which will wake the system up at the time specified in the next setting Resume Time Use this setting to specify the time you want the system to wake up the above setting must be set to On Enter the time with the number keys Resume on Modem Ring Use this setting to enable or disable the WOR Wake on Ring feature Options are On and Off 7 16 Chapter 7 BIOS 7 7 Boot Choose Boot from the Phoenix BIOS Setup Utility main menu with the arrow keys You should see the following display Highlighting a setting with a or will expand or collapse that entry See details on how to change the order and specs of boot devices in the Item Specific Help window All Boot BIOS settings are described in this section Phoenix BIOS Setup Utility Main Advanced Security Power Boot Exit Item Specific Help Removable Devices CD ROM Drive Hard Drive Network Boot Intel UNDI PXE 2 0 Intel UNDI PXE 2 0 F1 Help TL Select Item Change Values F9 Setup Defaults Esc Exit Select Menu Enter Select b Sub Menu F10 Save and Exit Removable Devices Highlight and press lt Enter gt to expand the field See details on how to change the order and specs of removable devices in the Item Specific Help window CD ROM Drive See details on how to change the order and specs of removable devices in the Item Specific Help window 7 17 SUPERSERVER 6013P 8 Manual Hard Drive Highlight and press lt Enter gt to expan
30. Phoenix BIOS Setup Utility Main Advanced Security Power Boot Exit Item Specific Help Select the drive type of the fixed Multi Sector Transfer 16 Sectors disk installed in LBA Mode Control Enabled your system If type 32 bit 1 0 Enabled User is selected Transfer Mode Fast PIO 4 Cylinders Heads Ultra DMA Mode Disabled and Sectors can be edited directly Auto attempts to automatically detect the drive type for drives that comply with ANSI specifications Fl Help N Select Item Change Values F9 Setup Defaults Esc Exit Select Menu Enter Select b Sub Menu F10 Save and Exit 74 Chapter 7 BIOS Type Selects the type of IDE hard drive The options are Auto allows BIOS to automatically determine the hard drive s capacity number of heads etc a number from 1 39 to select a predetermined type of hard drive CD ROM and ATAPI Removable Multi Sector Transfers Select the number of transfer sectors Options are 2 4 6 8 and 16 Sectors LBA Mode Control This item determines whether Phoenix BIOS will access the IDE Primary Master Device via LBA mode The options are Enabled and Disabled 32 bit I O Selects 32 bit I O operation Options are Enabled and Disabled Transfer Mode Selects the transfer mode Options are Standard Fast PIO1 Fast PIO2 Fast PIO3 Fast PIO4 FPIO3 DMA1 and FPIO4 DMA2 Ultra DMA Mode Selects Ultra DMA Mode Options are Disabled Mode 0 Mode 1 Mode 2 Mode 3
31. R 2 RD T RTS 3 TD 8 CTS 4 DTR 9 RI 5 Ground 10 NC Note Pin 10 is included on the header but not on the port PS 2 Keyboard and Mouse Port Pin Definitions J29 Pin Number Definition 1 Data 2 NC 3 Ground 4 VCC 5 Clock 6 NC Fan Header Pin Definitions Pin Number Definition 1 Ground black 2 12V red 3 Tachometer Caution These fan headers are DC power SUPERSERVER 6013P 8 User s Manual Power LED Speaker NMI Speaker Connector Pin Definitions JD1 On the JDI header pins 1 3 are Pin for a power LED pins 4 7 are for Number Function Definition 4 Red wire Speaker data the speaker and pins 8 9 are for 5 Key No connection F 6 Key the NMI connection See the table 7 Speaker data on the right for speaker pin defini tions Note The speaker connec tor pins are for use with an exter nal speaker If you wish to use the onboard speaker you should close pins 6 7 with a jumper Third Power Supply Fail Header Connect a cable from your power npe e aaa supply to the JP8 header to pro Pin vide warning of power supply fail Number EA FES ure This warning signal is Ee a EaI Sinal passed through the PWR_LED pin 4 Reset from MB on JF2 to indicate of a power fail ure on the chassis See the table on the right for pin definitions Note This feature is only avail able when using redundant Supermicr
32. SNK 0040 e Two 2 system blower fans FAN 0059 e Up to 12 GB ECC registered DDR266 200 SDRAM main memory optional e One 1 3 5 slim floppy drive e One 1 slim CD ROM drive e Two 2 riser cards CSE RR1U X and CSE RR1U XLP e SCSI Accessories One 1 SCA SAF TE compliant SCSI backplane CSE SCA 813S One 1 internal 68 pin Ultra320 SCSI cable CBL 037 U320 Four 4 SCA 1 inch high SCSI drive carriers CSE PT39 One 1 SCSI manual SUPERSERVER 6013P 8 Manual e Rackmount hardware with screws Two 2 rack rail assemblies Six 6 brackets for mounting the rack rails to a rack telco rack e One 1 CD ROM containing drivers and utilities e SuperServer 6013P 8 User s Manual 1 2 Serverboard Features At the heart of the SuperServer 6013P 8 lies the XSDPR 8G2 a dual Intel Xeon processor serverboard designed to provide maximum performance Below are the main features of the XSDPR 8G2 Chipset The X5DPR 8G2 is based on Intel s E7501 chipset which is a high performance chipset designed for dual processor servers see Figure 1 1 The E7501 chipset consists of four major components the Memory Controller Hub MCH the I O Controller Hub 3 ICH3 the PCI X 64 bit Hub 2 0 P64H2 and the 82808AA Host Channel Adapter VxB The MCH has four hub interfaces one to communicate with the ICH3 and three for high speed I O communications The MCH employs a 144 bit wide memory bus for a DDR266 PC2100 memory int
33. SUPERO SUPERSERVER 6013P 8 I EGLEOAOLI e re T HE m zl gt zi PJ USER S MANUAL The information in this User s Manual has been carefully reviewed and is believed to be accurate The vendor assumes no responsibility for any inaccuracies that may be contained in this document makes no commitment to update or to keep current the information in this manual or to notify any person or organization of the updates Please Note For the most up to date version of this manual please see our web site at www supermicro com SUPERMICRO COMPUTER reserves the right to make changes to the product described in this manual at any time and without notice This product including software if any and documentation may not in whole or in part be copied photocopied reproduced translated or reduced to any medium or machine without prior written consent IN NO EVENT WILL SUPERMICRO COMPUTER BE LIABLE FOR DIRECT INDIRECT SPECIAL INCIDENTAL SPECULATIVE OR CONSEQUENTIAL DAMAGES ARISING FROM THE USE OR INABILITY TO USE THIS PRODUCT OR DOCUMENTATION EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES IN PARTICULAR THE VENDOR SHALL NOT H
34. T Power On Self Test routine after the computer is turned on The settings are Enabled and Disabled If Disabled the POST routine will run at normal speed 7 6 Chapter 7 BIOS Quiet Boot This setting allows you to Enable or Disable the diagnostic screen during boot up Legacy USB Support This setting allows you to enable support for Legacy USB devices The settings are Enabled and Disabled Reset Configuration Data Options are Yes and No Choosing Yes will clear the Extended System Configuration Data ECSD P Cache Memory Access the submenu for this item to specify one of the following actions for various sections of cache memory Uncache Write Protect Write Back Write Through or Disable See the Item Specific Help window for details P1 O Device Configuration Access the submenu to make changes to the following settings Power Loss Control This setting allows you to choose how the system will react when power returns after an unexpected loss of power Options are Stay Off Power On and Last State Serial Port A This setting allows you to assign control of serial port A The options are Enabled user defined Disabled Auto BIOS controlled and OS Controlled Base I O Address Select the base I O address for serial port A The options are 3F8 2F8 3E8 and 2E8 7 7 SUPERSERVER 6013P 8 Manual Interrupt Select the IRQ interrupt request for serial port A Options are IRQ3 and
35. al Serial Bus Headers FPUSBO Front Panel Universal Serial Bus Pin Definitions FPUSBO FPUSB1 Two additional USB headers des Pin Pin u ignated FPUSBO and FPUSB1 are Sumber DefmionNumber Det on included on the serverboard x roe le POE 3 PO 3 PO These are included for connection 4 Ground 4 Ground N to the ports on the front of the A j5 sey chassis A USB cable not in cluded is needed See the table on the right for pin definitions 5 14 Chapter 5 Advanced Serverboard Setup Serial Ports The COM1 serial port is located under the parallel port See the table on the right for pin defini tions The COM2 connector is a header on the serverboard see serverboard layout for location ATX PS 2 Keyboard and PS 2 Mouse Ports The ATX PS 2 keyboard and the PS 2 mouse are located on J29 See the table on the right for pin defini tions The mouse port is to the right of the keyboard port See Figure 5 4 Fan Headers The serverboard has three fan headers These are designated CPU 1 Chassis Fan CPU 2 Chas sis Fan and Chassis Fan 3 See the table on the right for pin defini tions GLAN1 2 Ethernet Ports Two Ethernet ports designated GLAN1 and GLAN2 are located beside the VGA port on the IO backplane These ports accept RJ45 type cables Serial Port Pin Definitions COM1 COM2 Pin Number Definition Pin Number Definition 1 cD 6 DS
36. als back into their antistatic bags when not in use For grounding purposes make sure your computer chassis provides excellent conductivity between the power supply the case the mounting fasteners and the serverboard 4 3 SUPERSERVER 6013P 8 Manual 4 4 Operating Precautions A Care must be taken to assure that the chassis cover is in place when the 6013P 8 is operating to ensure proper cooling Out of warranty damage to the 6013P 8 system can occur if this practice is not strictly followed Chapter 5 Advanced Serverboard Setup Chapter 5 Advanced Serverboard Setup This chapter covers the steps required to install processors and heatsinks to the X5DPR 8G2 serverboard connect the data and power cables and install add on cards All serverboard jumpers and connections are de scribed and a layout and quick reference chart are included in this chapter Remember to close the chassis completely when you have finished working on the serverboard to protect and cool the system sufficiently 5 1 Handling the XSDPR 8G2 Serverboard Static electrical discharge can damage electronic components To prevent damage to printed circuit boards it is important to handle them very care fully see Chapter 4 Also note that the size and weight of the serverboard can cause it to bend if handled improperly which may result in damage To prevent the serverboard from bending keep one hand under the center of the board t
37. and drive A are properly identified Parity Check 1 nnnn Parity error found in the system bus BIOS attempts to locate the address and display it on the screen If it cannot locate the address it displays Parity is a method for checking errors in binary data A parity error indicates that some data has been corrupted A4 Appendix A BIOS POST Messages Parity Check 2 nnnn Parity error found in the I O bus BIOS attempts to locate the address and display it on the screen If it cannot locate the address it displays Press F1 to resume lt F2 gt to Setup lt F3 gt for previous Displayed after any recoverable error message Press lt F1 gt to start the boot process or lt F2 gt to enter Setup and change the settings Press lt F3 gt to display the previous screen usually an initialization error of an Option ROM i e an add on card Write down and follow the information shown on the screen Press lt F2 gt to enter Setup Optional message displayed during POST Can be turned off in Setup PS 2 Mouse PS 2 mouse identified Run the 120 Configuration Utility One or more unclaimed block storage devices have the Configuration Request bit set in the LCT Run an I2O Configuration Utility e g the SAC utility System BIOS shadowed System BIOS copied to shadow RAM UMB upper limit segment address nnnn Displays the address nnnn of the upper limit of Upper Memory Blocks indicating released segments of t
38. and note if it was damaged in any way If the server itself shows damage you should file a damage claim with the carrier who delivered it Decide on a suitable location for the rack unit that will hold the SuperServer 6013P 8 It should be situated in a clean dust free area that is well ventilated Avoid areas where heat electrical noise and electromagnetic fields are gener ated You will also need it placed near a grounded power outlet Be sure to read the Rack and Server Precautions in the next section 2 3 Preparing for Setup The box the SuperServer 6013P 8 was shipped in should include two sets of rail assemblies two rail mounting brackets and the mounting screws you will need to install the system into the rack Follow the steps in the order given to complete the installation process in a minimum amount of time Please read this section in its entirety before you begin the installation procedure outlined in the sections that follow 2 1 SUPERSERVER 6013P 8 Manual Choosing a Setup Location Leave enough clearance in front of the rack to enable you to open the front door completely 25 inches Leave approximately 30 inches of clearance in the back of the rack to allow for sufficient airflow and ease in servicing ZN Warnings and Precautions A N Rack Precautions Ensure that the leveling jacks on the bottom of the rack are fully extended to the floor with the full weight of the rack resting on them
39. anual System BIOS The BIOS is the Basic Input Output System used in all IBM PC XT AT and PS 2 compatible computers The PhoenixBIOS flash chip stores the system parameters such type of disk drives video displays etc in the CMOS The CMOS memory requires very little electrical power When the computer is turned off a back up battery provides power to the BIOS flash chip enabling it to retain system parameters Each time the computer is powered on the computer is configured with the values stored in the BIOS ROM by the system BIOS which gains control at boot up How To Change the Configuration Data The CMOS information that determines the system parameters may be changed by entering the BIOS Setup utility This Setup utility can be ac cessed by pressing the lt Delete gt key at the appropriate time during system boot see below Starting the Setup Utility Normally the only visible POST Power On Self Test routine is the memory test As the memory is being tested press the lt Delete gt key to enter the main menu of the BIOS Setup utility From the main menu you can access the other setup screens such as the Security and Power menus Begin ning with Section 7 3 detailed descriptions are given for each parameter setting in the Setup utility 7 1 SUPERSERVER 6013P 8 Manual 7 2 Running Setup Default settings are in bold text unless otherwise noted The BIOS setup options described in this section are
40. ard sized PCI card and one low profile PCI card see Figures 5 6a and 5 6b 2 PCI card installation Before installing a PCI add on card see step 1 above Begin by swing ing the release tab on the I O backpanel shield out to the left for the PCI slot Insert the PCI card into the correct slot on the butterfly riser card depending on whether it is a standard or low profile card pushing down with your thumbs evenly on both sides of the card Finish by pushing the release tab back to its original locked position Follow this procedure when adding a card to either slot Standard PCI and Low Profile PCI Expansion Card Comparison Figure 5 6a Low Profile vs Standard PCI Card Form Factor Figure 5 6b Low Profile PCI Card Dimensions 5 9 SUPERSERVER 6013P 8 User s Manual 5 7 Serverboard Details Figure 5 7 SUPER X5DPR 8G2 Layout not drawn to scale J28 Keyboard 15 DIMM 1A J I ATX POWER BANK 1 J29 Mouse DIMM 1B JPB I cl DIMM 2A I CPU1 Pac BANK 2 JP36 3 DIMM 2B Jd COM DIMM 43A 7 CPU1 Chassis
41. ble Devices optional Initialize BIOS Data Area Enable Non Maskable Interrupts NMIs Initialize Extended BIOS Data Area Test and initialize PS 2 mouse Initialize floppy controller Determine number of ATA drives optional Initialize hard disk controllers Initialize local bus hard disk controllers Jump to UserPatch2 Build MPTABLE for multi processor boards Install CD ROM for boot Clear huge ES segment register Fix up Multi Processor table 1 2 Search for option ROMs One long two short beeps on checksum failure B 3 SUPERSERVER 6013P 8 Manual POST Code 99h 9Ah 9Ch 9Dh 9Eh 9Fh AOh A2h A4h A8h AAh ACh AEh BOh Bih B2h B4h B5h B6h B7h B9h BAh BBh BCh BDh BEh BFh COh Cih C2h C3h C4h C5h C6h C7h C8h C9h CAh CBh CCh Description Check for SMART Drive optional Shadow option ROMs Set up Power Management Initialize security engine optional Enable hardware interrupts Determine number of ATA and SCSI drives Set time of day Check key lock Initialize typematic rate Erase F2 prompt Scan for F2 key stroke Enter SETUP Clear Boot flag Check for errors Inform RomPilot about the end of POST POST done prepare to boot operating system 1 One short beep before boot Terminate QuietBoot optional Check password optional Initialize ACPI BIOS Prepare Boot Initialize SMBIOS Initialize PnP Option ROMs Clear parity checkers Display MultiBoot menu Clear screen opt
42. d the field See details on how to change the order and specs of hard drives in the Item Specific Help window Network Boot See details on how to change the order and specs of network boot devices in the Item Specific Help window Intel UNDI PXE 2 0 See details on how to change the order and specs of Intel UNDI devices in the Item Specific Help window Chapter 7 BIOS 7 8 PIR Choose PIR from the Phoenix BIOS Setup Utility main menu with the arrow keys You should see the following display The items with a triangle beside them have sub menus that can be accessed by highlighting the item and pressing lt Enter gt PIR stands for Processor Info ROM which allows BIOS to read certain information from the processors Options for PIR settings are displayed by highlighting the setting option using the arrow keys and pressing lt Enter gt All PIR BIOS Setup options are described in this section Phoenix BIOS Setup Utility Main Advanced Security Power Boot PIR Exit Item Specific Help Select the Processor s PIR Select the Thermal Unit gt Processor Info ROM Data gt Hardware Monitor Logic F1 Help Tl select Item Change Values F9 Setup Defaults Esc Exit Select Menu Enter Select b Sub Menu F10 Save and Exit Select the Processor s PIR Selects the processor PIR Options are AOh A1h A2h A3h A4h A5h A6h A7h A8h A8h AAh ABh ACh ADh and AEh AFh Select the Thermal Unit Selects the thermal unit Opti
43. e from the motherboard Unscrew the failed blower fan from the chassis and pull it completely out from the serverboard 2 Installing a new fan Replace the failed fan with an identical 10 cm 12 volt fan available from Supermicro p n FAN 0059 Install the new fan in its proper place in the chassis by positioning it on the two mounting posts Secure the fan to the chassis with the screws you removed previously then attach the fan wires to the same chassis fan header you removed it from Make sure the air seal under the fan is properly installed and creating a good seal Power up the system and check that the fan is working properly and that the LED on the control panel has turned off Finish by replacing the chassis cover SUPERSERVER 6013P 8 Manual 10 cm Blower Fans Figure 6 2 System Cooling Fans with optional front bezel shown 6 4 Drive Bay Installation Removal Removing the Front Bezel If your system has a front bezel optional attached to the chassis you must first remove it to gain access to the drive bays To remove the bezel first unlock the front of the chassis then press the release knob see Figure 6 3 Carefully remove the bezel with both hands A filter located within the bezel can be removed for replacement cleaning It is recommended that you keep a maintenance log of filter cleaning replacement since its condition will affect the airflow throughout the whole system Chapter 6 Advanced Chassis Setup
44. el Ultra320 SCSI at a burst throughput rate of 320 MB sec The X5DPR 8G2 provides two SCSI ports A QLogic GEM318 controller is used for the SAF TE compliant SCSI backpanel PCI Expansion Slots The X5DPR 8G2 has one 64 bit 183 MHz PCI X slot and one slim 64 bit 66 MHz PCI slot A butterfly riser card is included with the server This riser card fits into the 133 MHz PCI X slot and was designed specially for the SC813S chassis to support the use of one standard PCI card and one low profile half height half length PCI card Several jumpers on the serverboard are used to change the speeds of these slots if needed see Chapter 5 ATI Graphics Controller The X5DPR 8G2 features an integrated ATI video controller based on the Rage XL graphics chip Rage XL fully supports sideband addressing and AGP textur ing This onboard graphics package can provide a bandwidth of up to 512 MB Sec over a 32 bit graphics memory bus SUPERSERVER 6013P 8 Manual Onboard Controllers Ports The X5DPR 8G2 includes one floppy drive controller and two onboard IDE con trollers which support up to four hard drives or ATAPI devices Backpanel I O ports include one COM port two USB ports PS 2 mouse and keyboard ports a video monitor port and an external SCSI port An Intel 82546 Ethernet controller is included to support two Gb LAN ports Other Features Other onboard features are included to promote system health These include various vo
45. erface which provides a total bandwidth of up to 4 2 GB s The ICH3 interface is a 266 MB sec point to point connection using an 8 bit wide 66 MHz base clock at a 4x data transfer rate The P64H2 interface is a 1 GB s point to point connection using a 16 bit wide 66 MHz base clock at a 8x data transfer rate The ICH3 I O Controller Hub provides various integrated functions including a two channel UDMA100 bus master IDE controller USB host controllers a Sys tem Management Bus controller and an AC 97 compliant interface The P64H2 PCI X Hub provides a 16 bit connection to the MCH for high perfor mance IO capability and the 64 bit PCI X interface 1 2 Chapter 1 Introduction Processors The X5DPR 8G2 supports single or dual Intel 604 603 pin Xeon processors of up to 3 20 GHz at a 533 400 MHz FSB Please refer to the support section of our web site for a complete listing of supported processors http www supermicro com TechSupport htm Memory The X5DPR 8G2 has 6 184 pin DIMM slots that can support up to 12 GB of low profile registered ECC DDR266 200 PC2100 1600 SDRAM Module sizes of 128 MB 256 MB 512 MB 1 GB and 2 GB may be used to populate the DIMM slots This serverboard has has been designed to support 2GB DIMM modules for each memory slot but it has only been validated with 1GB memory modules Onboard SCSI Onboard SCSI is provided with an Adaptec AIC 7902 SCSI controller chip which supports dual chann
46. hanges Highlight this item and hit lt Enter gt to exit the BIOS Setup utility without saving any changes you may have made Load Setup Defaults Highlight this item and hit lt Enter gt to load the default settings for all items in the BIOS Setup These are the safest settings to use Discard Changes Highlight this item and hit lt Enter gt to discard cancel any changes you made You will remain in the Setup utility Save Changes Highlight this item and hit lt Enter gt to save any changes you made You will remain in the Setup utility 7 22 Appendix A BIOS POST Messages Appendix A BIOS POST Messages During the Power On Self Test POST the BIOS will check for problems If a problem is found the BIOS will activate an alarm or display a message The following is a list of such BIOS messages Failure Fixed Disk Fixed disk is not working or not configured properly Check to see if fixed disk is attached properly Run Setup Find out if the fixed disk type is correctly identified Stuck key Stuck key on keyboard Keyboard error Keyboard not working Keyboard Controller Failed Keyboard controller failed test May require replacing keyboard controller Keyboard locked Unlock key switch Unlock the system to proceed Monitor type does not match CMOS Run SETUP Monitor type not correctly identified in Setup Shadow Ram Failed at offset nnnn Shadow RAM failed at offset nnnn of the 64k block at which
47. he BIOS which can be reclaimed by a virtual memory manager Video BIOS shadowed Video BIOS successfully copied to shadow RAM AS SUPERSERVER 6013P 8 Manual Notes A 6 Appendix B BIOS POST Codes Appendix B BIOS POST Codes This section lists the POST Power On Self Test codes for the PhoenixBIOS POST codes are divided into two categories recoverable and terminal Recoverable POST Errors When a recoverable type of error occurs during POST the BIOS will display an POST code that describes the problem BIOS may also issue one of the following beep codes 1 long and two short beeps video configuration error 1 continuous long beep no memory detected Terminal POST Errors If a terminal type of error occurs BIOS will shut down the system Before doing so BIOS will write the error to port 80h attempt to initialize video and write the error in the top left corner of the screen The following is a list of codes that may be written to port 80h POST Code Description 02h Verify Real Mode 03h Disable Non Maskable Interrupt NMI 04h Get CPU type 06h Initialize system hardware 07h Disable shadow and execute code from the ROM 08h Initialize chipset with initial POST values 09h Set IN POST flag OAh Initialize CPU registers OBh Enable CPU cache OCh Initialize caches to initial POST values OEh Initialize I O component OFh Initialize the local bus IDE 10h Initialize Power Management 11h Load
48. ified device Allocation Error for device Run ISA or EISA Configuration Utility to resolve resource conflict for the specified device CD ROM Drive CD ROM Drive identified Entering SETUP Starting Setup program Failing Bits nnnn The hex number nnnn is a map of the bits at the RAM address which failed the memory test Each 1 one in the map indicates a failed bit See errors 230 231 or 232 above for offset address of the failure in System Extended or Shadow memory A 3 SUPERSERVER 6013P 8 Manual Fixed Disk n Fixed disk n 0 3 identified Invalid System Configuration Data Problem with NVRAM CMOS data 1 0 device IRQ conflict l O device IRQ conflict error PS 2 Mouse Boot Summary Screen PS 2 Mouse installed nnnn kB Extended RAM Passed Where nnnn is the amount of RAM in kilobytes successfully tested nnnn Cache SRAM Passed Where nnnn is the amount of system cache in kilobytes successfully tested nnnn kB Shadow RAM Passed Where nnnn is the amount of shadow RAM in kilobytes successfully tested nnnn kB System RAM Passed Where nnnn is the amount of system RAM in kilobytes successfully tested One or more 120 Block Storage Devices were excluded from the Setup Boot Menu There was not enough room in the IPL table to display all installed 120 block storage devices Operating system not found Operating system cannot be located on either drive A or drive C Enter Setup and see if fixed disk
49. ional Check virus and backup reminders Try to boot with INT 19 Initialize POST Error Manager PEM Initialize error logging Initialize error display function Initialize system error handler PnPnd dual CMOS optional Initialize note dock optional Initialize note dock late Force check optional Extended checksum optional Redirect Int 15h to enable remote keyboard Redirect Int 13h to Memory Technologies Devices such as ROM RAM PCMCIA and serial disk Redirect Int 10h to enable remote serial video B 4 Appendix B BIOS POST Codes POST Code CDh CEh D2h Description Re map I O and memory for PCMCIA Initialize digitizer and display message Unknown interrupt The following are for boot block in Flash ROM POST Code EOh Eth E2h E3h E4h E5h E6h E7h E8h E9h EAh EBh ECh EDh EEh EFh FOh Fih F2h F3h F4h F5h F6h F7h Description Initialize the chipset Initialize the bridge Initialize the CPU Initialize system timer Initialize system I O Check force recovery boot Checksum BIOS ROM Go to BIOS Set Huge Segment Initialize Multi Processor Initialize OEM special code Initialize PIC and DMA Initialize Memory type Initialize Memory size Shadow Boot Block System memory test Initialize interrupt vectors Initialize Run Time Clock Initialize video Initialize System Management Manager Output one beep Clear Huge Segment Boot to Mini DOS Boot to Full DOS If the BIOS detects error 2C
50. itions Power LED PWR LED Pin Definitions JF2 The Power LED connection is lo Pin Number Definition cated on pins 15 and 16 of JF2 15 Voc Refer to the table on the right for 16 Control pin definitions HDD LED The HDD IDE Hard Disk Drive LED job connection is located on pins 13 JF2 and 14 of JF2 Attach the IDE hard n scii drive LED cable to display disk ac 13 Voc 14 HD Active tivity Refer to the table on the right for pin definitions 5 12 Chapter 5 Advanced Serverboard Setup NIC1 LED The NIC1 Network Interface Con E troller LED connection is located JF2 on pins 11 and 12 of JF2 Attach TEET the NIC1 LED cable to display net n Ed work activity Refer to the table on the right for pin definitions NIC2 LED NIC2 LED Pin The NIC2 Network Interface Con Definitions troller LED connection is located ee on pins 9 and 10 of JF2 Attach er bride the NIC2 LED cable to display net i aun work activity Refer to the table on the right for pin definitions Overheat LED OH Overheat OH LED Pin Definitions Connect an LED to the OH connec JF2 tion on pins 7 and 8 of JF2 to pro Pin A Number Definition vide advanced warning of chassis 7 Vcc overheating Refer to the table on 8 GND the right for pin definitions Power Fail LED Power Fail LED Pin The Power Fail LED connection is ER loca
51. l Intel ETTI chspeiel IHF ei SUPERMICRG amp Micearnoft Discs B T Drivers amp Tools ATI Giaphici diei XspP amp z amp SUPERM DAD Supsa Daciu I IIl e E Intel LOCH EZ for SUPERMICRO Intel chipset tava board e al Bull LAN SCS drisi dostie amd nennt e Brees CD F inis St Up Hes Times For more ini cemakion please vidit SLIPEFSHICRET S pas tlg Intel E7501 Chipset SUPERMICRO Compl Inc Figure 5 8 Driver Tool Installation Display Screen Click the icons showing a hand writing on paper to view the readme files for each item The bottom icon with a CD on it allows you to view the entire contents of the CD 5 24 Chapter 6 Advanced Chassis Setup Chapter 6 Advanced Chassis Setup This chapter covers the steps required to install components and perform maintenance on the SC813S chassis For component installation follow the steps in the order given to eliminate the most common problems encoun tered If some steps are unnecessary skip ahead to the next step Tools Required The only tool you will need to install components and perform maintenance is a Philips screwdriver 6 1 Static Sensitive Devices Electricstatic discharge ESD can damage electronic components To pre vent damage to any printed circuit boards PCBs it is important to handle them very carefully The following measures are generally sufficient to protect your equipment from ESD damage Precautions Use a g
52. led Primary Master 120 GB Primary Slave None Secondary Master CD ROM Secondary Slave None System Memory 256 MB Extended Memory 3967 KB F1 Help TL Select Item Change Values F9 Setup Defaults Esc Exit 2 Select Menu Enter Select b Sub Menu F10 Save and Exit Main Setup Features System Time To set the system date and time key in the correct information in the appropriate fields Then press the Enter key to save the data System Date Using the arrow keys highlight the month day and year fields and enter the correct data Press the Enter key to save the data 7 3 SUPERSERVER 6013P 8 Manual Legacy Diskette A This setting allows the user to set the type of floppy disk drive installed as diskette A The options are Disabled 360Kb 5 25 in 1 2MB 5 25 in 720Kb 3 5 in 1 44 1 25MB 3 5 in and 2 88MB 3 5 in Legacy Diskette B This setting allows the user to set the type of floppy disk drive installed as diskette B The options are Disabled 360Kb 5 25 in 1 2MB 5 25 in 720Kb 3 5 in 1 44 1 25MB 3 5 in and 2 88MB 3 5 in gt Primary Master Primary Slave Secondary Master Secondary Slave These settings allow the user to set the parameters of the IDE Primary Master Slave and IDE Secondary Master Slave slots Hit lt Enter gt to activate the following sub menu screen for detailed options of these items Set the correct configurations accordingly The items included in the sub menu are
53. long bracket to the rear side of the outer rail with three M4 screws Repeat these steps for the left outer rail Locking Tabs Both chassis rails have a locking tab which serves two functions The first is to lock the server into place when installed and pushed fully into the rack which is its normal position Secondly these tabs also lock the server in place when fully extended from the rack This prevents the server from coming completely out of the rack when you pull it out for servicing Figure 2 2 Installing the Rack Rails 2 4 Chapter 2 Server Installation Installing the Server into the Rack You should now have rails attached to both the chassis and the rack unit The next step is to install the server into the rack Do this by lining up the rear of the chassis rails with the front of the rack rails Slide the chassis rails into the rack rails keeping the pressure even on both sides you may have to depress the locking tabs when inserting See Figure 2 3 When the server has been pushed completely into the rack you should hear the locking tabs click Finish by inserting and tightening the thumbscrews that hold the front of the server to the rack Figure 2 3 Installing the Server into a Rack 2 5 SUPERSERVER 6013P 8 Manual Installing the Server into a Telco Rack If you are installing the SuperServer 6013P 8 into a Telco type rack follow the directions given on the previous page
54. lso be Disabled BAUD Rate Select the BAUD rate for console redirection Console Type Choose from the available options to select the console type for console redirection Flow Control Choose from the available options to select the flow control for console redirection Console Connection Select the console connection either Direct or Via Modem Continue CR after POST Choose whether to continue with console redirection after the POST routine Options are On and Off of Video Pages to Support Choose the number of video pages to allocate for redirection when video hardware is not available Options are 1 2 3 4 5 6 7 and 8 7 12 Chapter 7 BIOS 7 5 Security Choose Security from the Phoenix BIOS Setup Utility main menu with the arrow keys You should see the following display Security setting options are displayed by highlighting the setting using the arrow keys and pressing lt Enter gt All Security BIOS settings are described in this section Phoenix BIOS Setup Utility Main Advanced Securit Power Boot Exit Item Specific Help Supervisor Password Is Clear User Password Is Clear Quiet Boot Disabled Set Supervisor Password Enter Set User Password Enter Password on Boot Disabled Fixed Disk Boot Sector Normal F1 Help TL Select Item Change Values F9 Setup Defaults Esc Exit Select Menu Enter Select gt Sub Menu F10 Save and Exit Supervisor Password Is This di
55. ltage monitors two CPU temperature sensors four fan speed sensors a chassis intrusion header auto switching voltage regulators chassis and CPU overheat sensors virus protection and BIOS rescue Figure 1 1 E7501 Chipset Block Diagram jag 539 400 MHz System Bus seater gt PCLX Slot 5 Gb LAN IcH S PCI X Slot 6 SXB mE gt PO X Slots 1 3 gt PO X Slot 4 SCSI SperlO Graphics 266 MHz Memory Bus ano 7 2 Channel DDR SDRAM 14 Chapter 1 Introduction 1 3 Server Chassis Features The SC8138 is one of Supermicro s third generation 1U chassis and features four hot swap SCSI hard drive bays a slim CD ROM drive a slim 3 5 floppy drive and a revolutionary cooling design that can keep today s most powerful processors running well below their temperature thresholds The following is a general outline of the main features of the SC813S chassis System Power When configured as a SuperServer 6013P 8 the SC8138 chassis includes a 500W cold swap power supply SCSI Subsystem The SCSI subsystem supports four 80 pin SCA Ultra320 SCSI hard drives Any standard 1 drives are supported SCA Single Connection Attachment The SCSI drives are connected to an SCA backplane that provides power bus termi nation and configuration settings The SCSI drives are also hot swap units Control Panel The SC813S cont
56. n also terminate POST and cause this error on the next boot Run Setup and verify that the waitstate configuration is correct This error is cleared the next time the system is booted Memory Size found by POST differed from CMOS Memory size found by POST differed from CMOS Diskette drive A error Diskette drive B error Drive A or B is present but fails the BIOS POST diskette tests Check to see that the drive is defined with the proper diskette type in Setup and that the diskette drive is attached correctly Incorrect Drive A type run SETUP Type of floppy drive A not correctly identified in Setup Incorrect Drive B type run SETUP Type of floppy drive B not correctly identified in Setup A2 Appendix A BIOS POST Messages System cache error Cache disabled RAM cache failed and BIOS disabled the cache On older boards check the cache jumpers You may have to replace the cache See your dealer A disabled cache slows system performance considerably CPUID CPU socket number for Multi Processor error EISA CMOS not writeable ServerBIOS2 test error Cannot write to EISA CMOS DMA Test Failed ServerBIOS2 test error Cannot write to extended DMA Direct Memory Access registers Software NMI Failed ServerBIOS2 test error Cannot generate software NMI Non Maskable Interrupt Fail Safe Timer NMI Failed ServerBlOS2 test error Fail Safe Timer takes too long device Address Conflict Address conflict for spec
57. n the serverboard to provide you with system status indications A ribbon cable has bundled these wires together to simplify the connection Connect the cable from JF2 on the serverboard to the appro priate header on the Control Panel PCB printed circuit board Make sure the red wire plugs into pin 1 on both connectors Pull all excess cabling out of the airflow path The control panel LEDs inform you of system status See Chapter 3 System Interface for details on the LEDs and the control panel buttons Details on JF2 can be found in Chapter 5 Advanced Serverboard Setup 6 2 Chapter 6 Advanced Chassis Setup 6 3 System Fans Two 10 cm blower fans provide all the cooling needed for the SuperServer 6013P 8 lt is very important that the chassis top cover is properly installed and making a good seal in order for the cooling air to circulate properly through the chassis and cool the components See Figure 6 2 System Fan Failure The fans run at 5000 rpm If a fan fails the ambient air temperature in the chassis will rise and activate the overheat LED on the control panel Replace any failed fan immediately with the same type and model You must power down the system before replacing a cooling fan removing the power cord is also recom mended as a safety precaution Replacing System Cooling Fans 1 Removing a fan After turning off the power to the system first remove the chassis cover and unplug the fan cabl
58. nced Chassis Setup 6 5 Power Supply The SuperServer 6013P 8 has a single 500 watt power supply which is auto switching capable This enables it to automatically sense and operate with either a 100v or 240v input voltage An amber light will be illuminated on the power supply when the power is off An illuminated green light indicates that the power supply is operating Power Supply Failure If the power supply unit fails the system will shut down and you will need to replace the unit Replacement units can be ordered directly from Supermicro see contact information in the Preface As there is only one power supply unit in the 6013P 8 power must be completely removed from the server before removing and replacing the power supply unit for whatever reason Removing Replacing the Power Supply 1 Removing the power supply First turn the power switch on the control panel off then unplug the power cord from the system Remove the chassis cover by pressing the two release buttons on the top of the chassis near the front and push the chassis top rearward about one inch To remove the failed power unit push the beige colored release tab to the right and then carefully lift the unit up about 1 2 inch only If you lift too high you may damage the power distribution board that the other end of the unit is connected to Then pull the power unit straight back to unplug it from the power distribution board See Figure 6 6 2
59. ng e ERENI connector Pin 1 is identified Pin 1 2 short with a square solder pad on the printed circuit board See the serverboard layout page for jumper locations Note On two pin jumpers Closed means the jumper is on and Open means the jumper is off the pins CMOS Clear JBT1 is used to clear CMOS Instead of pins this jumper consists of con tact pads to prevent accidentally clearing the contents of CMOS To clear CMOS 1 First unplug the power cord s 2 With the power disconnected short the CMOS pads with a metal object such as a small screwdriver 3 Remove the screwdriver or shorting device 4 Reconnect the power cord s and power on the system Note Do not use the PW ON connector to clear CMOS Chapter 5 Advanced Serverboard Setup GLAN Enable Disable GLAN Enable Disable Jumper Settings JD4 Change the setting of jumper JD4 dumper to enable or disable the onboard Position Definition Pins 1 2 Enabled GLAN ports GLAN1 and GLAN2 Pins2 3 Disabled on the serverboard See the table on the right for jumper settings The default setting is enabled VGA Enable Disable VGA Enable Disable Jumper Settings JP4 JP4 allows you to enable or disable Jumper the VGA port The default position Position Definition 1 2 Enabled is on pins 1 and 2 to enable VGA 2 8 Disabled See the table on the right for jumper settings Front Side Bus Speed F
60. ntents Chapter 7 BIOS Hed Introductionis sci renes Eee rm erisept terere He te EH EX EUER EEUEAR ERES 7 1 7 2 RUNNING Setup uunc ter iie e eget dr decns 7 2 7 3 Main BIOS SStUp eerte rent emper ete ete ui eim di A 7 2 Main BIOS Setup Me riu 1 ctn terere tet edi 7 8 TA Advanced Setup em eite mdi Rad Es reei cR RE ean 7 6 725 gt SOCUNILY C duets 7 13 7 6 7 7 7 8 7 9 Appendices Appendix A BIOS POST Messages esee nenne nnne nnn A 1 Appendix B BIOS POST Odes e rrr tae ce oa Appendix C System Specifications SUPERSERVER 6013P 8 User s Manual Notes Chapter 1 Introduction Chapter 1 Introduction to the SuperServer 6013P 8 1 1 Overview The Supermicro SuperServer 6013P 8 is a high end dual processor 1U rackmount server that features some of the most advanced technology currently available The SuperServer 6013P 8 is comprised of two main subsystems the C813S 1U rackmount chassis and the XSDPR 8G2 dual Xeon processor serverboard Please refer to our web site for information on operating systems that have been certified for use with the SuperServer 6013P 8 www supermicro com In addition to the mainboard and chassis various hardware components may have been included with your SuperServer 6013P 8 as listed below e Up to two 2 604 or 603 pin Intel Xeon processors of up to 3 20 GHz optional e Two 2 1U CPU heatsinks
61. o power supplies and so does not apply to the 6013P 8 Chassis Intrusion A Chassis Intrusion header is lo cated at JL1 Attach the appropri ate cable to inform you of a chas sis intrusion Chapter 5 Advanced Serverboard Setup Wake On LAN Wake On LAN Pin Definitions WOL The Wake On LAN header is des Pin j Number Definition ignated as WOL See the table on av Standby the right for pin definitions You 2 Ground Wake must enable the LAN Wake Up set x ting in BIOS to use this feature You must also have a LAN card with a Wake on LAN connector and cable Wake On Ring The Wake On Ring header is des Ec mi ignated WOR This function al WOR lows your computer to receive oM IR and wake up by an incoming call 1 Pads 2 M to the modem when in sustpend a state See the table on the right for pin definitions You must have a WOR card and cable to use this feature Keylock The keyboard lock connection is lo cated on JP35 Utilizing this header allows you to inhibit any actions made on the keyboard effectively locking it SUPERSERVER 6013P 8 User s Manual 5 9 Jumper Settings Explanation of Jumpers Connector 32 1 Pins To modify the operation of the e serverboard jumpers can be used to choose between p Jumper optional settings Jumpers Cap create shorts between two pins 3 2 1 to change the function of the 2 A E vei Setti
62. o support it when handling The following measures are gener ally sufficient to protect your equipment from static discharge Precautions Use a grounded wrist strap designed to prevent static discharge Touch a grounded metal object before removing any board from its anti static bag Handle a board by its edges only do not touch its components periph eral chips memory modules or gold contacts When handling chips or modules avoid touching their pins Put the serverboard add on cards and peripherals back into their anti static bags when not in use Unpacking The serverboard is shipped in antistatic packaging to avoid static damage When unpacking the board make sure the person handling it is static pro tected SUPERSERVER 6013P 8 User s Manual 5 2 PGA Processor and Heatsink Installation When handling the processor package avoid placing direct pressure on the label area of the fan Also do not place the serverboard on a conductive surface which can damage the BIOS battery and prevent the system from booting up IMPORTANT Always connect the power cord last and always remove it before adding removing or changing any hardware components Make sure that you install the processor into the CPU socket before you install the heatsink The X5DPR 8G2 can support either one or two Xeon 604 or 603 pin processors of up to 3 20 GHz and faster If installing one processor only install it into CPU socket 1
63. ons are 30h 31h 32h 33h 34h 35h 52h 53h 54h 55h 56h 57h 98h 99h 9Ah 9Bh and 9Ch 9Dh 7 19 SUPERSERVER 6013P 8 Manual P Processor Info ROM Data Highlight this and hit Enter to see PIR data on the following items Header Info Processor Data Processor Core Data L3 Cache Data Package Data Part Number Data Thermal Reference Data Feature Data Other Data OEM Data b Hardware Monitor Logic Highlight this and hit Enter to see monitor data for the following items CPU1 Temperature CPU2 Temperature System Temperature CPU Fan1 CPU1 Chassis Fan CPU Fan2 CPU2 Chassis Fan Chassis Fan 1 7 20 Chapter 7 BIOS Chassis Fan 2 Processor Vcore 3 3V Standby 3 3V Vcc 5V Vcc 12V Vcc 1 8V Vcc 12V Vcc 7 9 Exit Choose Exit from the Phoenix BIOS Setup Utility main menu with the arrow keys You should see the following display All Exit BIOS settings are described in this section Phoenix BIOS Setup Utility Main Advanced Security Power PIR Exit Item Specific Help Exit Saving Changes Exit Discarding Changes Load Setup Defaults Discard Changes Save Changes F1 Help Tl select Item Change Values F9 Setup Defaults Esc Exit Select Menu Enter Select b Sub Menu F10 Save and Exit 7 21 SUPERSERVER 6013P 8 Manual Exit Saving Changes Highlight this item and hit lt Enter gt to save any changes you made and to exit the BIOS Setup utility Exit Discarding C
64. oppy Disk Drive Connector JP8 Third Power Supply Fail Header JP35 Keylock Header JP36 Alarm Reset Switch J15 Secondary ATX Power Connector J28 Keyboard Port J29 Mouse Port GLAN1 2 Ethernet Ports OHLED Overheat LED Header USBO 1 Universal Serial Bus Ports VGA VGA Display Monitor Port WOL Wake on LAN Header WOR Wake on Ring Header SUPERSERVER 6013P 8 User s Manual 5 8 Connector Definitions ATX Power Connection ATX Power Supply 20 pin Connector Pin Number Definition Pin Number Definition 11 3 3V 1 3 3V The power supply connector 12 12V 2 3 3V 13 COM 3 COM meets the SSI Superset ATX 20 a PS ON pes pin specification Make sure that 15 COM 5 COM 16 COM 6 45V the orientation of the connector is 17 COM 7 COM 18 5V 8 PW OK correct See the table on the right 19 ps S V B for pin definitions 20 5V 10 12V PWR_SEC Connection 8 Pin 12v Power Supply Connector J15 In addition to the Primary ATX ios Demi power connector above the Ping Definition i 1 thru 4 Ground Secondary 12v 8 pin J15 connec Sthrus 12v tor must also be connected to your power supply See the table on the right for pin definitions NMI Button NMI Button Pin Definitions JF2 The non maskable interrupt button Pin header is located on pins 19 and Number Definition 19 C l 20 of JF2 Refer to the table on 5 rie the right for pin defin
65. r dual Xeon processors of up to 3 20 GHz at a Front Side system Bus speed of 533 400 MHz and up to 12 GB of DDR266 200 PC2100 1600 low profile SDRAM memory Manual Organization Chapter 1 Introduction The first chapter provides a checklist of the main components included with the server system and describes the main features of the SUPER X5DPR 8G2 serverboard and the SC813S chassis which make up the SuperServer 6013P 8 Chapter 2 Server Installation This chapter describes the steps necessary to install the SuperServer 6013P 8 into a rack and check out the server configuration prior to powering up the System If your server was ordered without processor and memory components this chapter will refer you to the appropriate sections of the manual for their installation Chapter 3 System Interface Refer here for details on the system interface which includes the functions and information provided by the control panel on the chassis as well as other LEDs located throughout the system SUPERSERVER 6013P 8 Manual Chapter 4 System Safety You should thoroughly familiarize yourself with this chapter for a general overview of safety precautions that should be followed when installing and servicing the SuperServer 6013P 8 Chapter 5 Advanced Serverboard Setup Chapter 5 provides detailed information on the XSDPR 8G2 serverboard including the locations and functions of connectors headers and jumpers Refer to this chap
66. r to the installation instructions that came with the rack unit you are using Identifying the Sections of the Rack Rails You should have received two rack rail assemblies with the SuperServer 6013P 8 Each of these assemblies consists of two sections an inner fixed chassis rail that secures to the 6013P 8 A and an outer fixed rack rail that secures directly to the rack itself B Two pairs of short brackets to be used on the front side of the outer rails are also included Installing the Inner Rails First locate the right inner rail the rail that will be used on the right side of the chassis when you face the front of the chassis Align the four square holes on the right inner rail against the hooks on the right side of the chassis Securely attach the rail to the chassis with two M4 flat head screws Repeat these steps to install the left inner rail to the left side of the chassis Figure 2 1 SC813S with Rack Rails Attached with optional front bezel shown 2 3 SUPERSERVER 6013P 8 Manual Installing the Outer Rails Begin by measuring the distance from the front rail to the rear rail of the rack Attach a short bracket to the front side of the right outer rail and a long bracket to the rear side of the right outer rail Adjust both the short and long brackets to the proper distance so that the rail can fit snugly into the rack Secure the short bracket to the front side of the outer rail with two M4 screws and the
67. rol panel provides important system monitoring and control information LEDs indicate power on network activity hard disk drive activity and system overheat conditions Also present are a main power button and a System reset button I O Backplane The SC813S is a 1U rackmount chassis Its I O backplane provides one full height full length and one half height half length PCI slots one COM port the other is internal one VGA port two USB ports PS 2 mouse and keyboard ports and two Ethernet LAN ports See Figure 1 2 SUPERSERVER 6013P 8 Manual Keyboard Port Mouse Port Low Profile PCI Slot Standard PCI Slot Hen UWI II USB Ports COM1 Port Ethernet Ports VGA Port Ext SCSI Port Figure 1 2 I O Backplane Cooling System The SC813S chassis revolutionary cooling design has been optimized to provide sufficient cooling for dual Xeon configurations The SC8138 includes two heavy duty 10 cm blower fans located in the middle of the chassis These fans operate continuously at full rpm If they break down the ambient air temperature inside the chassis will rise and activate an overheat LED 1 6 Chapter 1 Introduction 1 4 Contacting Supermicro Headquarters Address Tel Fax Email Web Site Europe Address Tel Fax Email Asia Pacific Address Tel Fax Web Site SuperMicro Computer Inc 980 Rock Ave San Jose CA 95
68. ront Side Bus Speed Jumper Settings JP38 JP38 is used to set the system Jumper i i Position Definition front side bus speed for the pro Pine 19 un cessors t is best to keep this Pins 2 3 400 MHz Open 533 Mhz jumper set to Auto This jumper is used together with the CPU Ratio Frequency setting in BIOS See the table on the right for jumper settings SCSI Enable Disable SCSI Enable Disable Jumper Settings JP22 The SCSI Termination jumper at Tuner JP22 allows you to enable or dis Position Definition Pins 1 2 Enabled able the onboard SCSI controller Pins 2 3 Disabled The normal default position is on pins 1 2 to enable SCSI termina tion See the table on the right for jumper settings 5 19 SUPERSERVER 6013P 8 User s Manual SCSI Termination Enable SCSI Channel Termination Disable Enable Disable Jumper Settings JPA1 JPA2 Jumpers JPA1 and JPA2 allow you Jumper to enable or disable termination for Position Definition un Open Enabled the individual SCSI channels Closed Disabled Jumper JPA1 controls SCSI channel A and JPA2 controls SCSI channel B The normal default setting is open to enable teminate both SCSI channels If you wish to connect external SCSI devices you should disable termination for the channnel s you will be connecting them to See the table on the right for jumper settings Watch Dog Enable Di
69. rounded wrist strap designed to prevent static discharge Touch a grounded metal object before removing any board from its anti static bag Handle a board by its edges only do not touch its components periph eral chips memory modules or gold contacts When handling chips or modules avoid touching their pins Put the serverboard add on cards and peripherals back into their anti static bags when not in use For grounding purposes make sure your computer chassis provides ex cellent conductivity between the power supply the case the mounting fasteners and the serverboard SUPERSERVER 6013P 8 Manual Slim Line CD ROM Drive Floppy Drive System LEDs Control Panel ELI 00l ry HSS Set D C eal ul H J SCSI Drives System Reset Main Power 5 d 3 E Du EE EE ELE A o 6 y hi C 1 T 2 v i C rm o sig CIC der i os JS a po Figure 6 1 Chassis Front and Rear Views 6 2 Control Panel The control panel located on the front of the chassis must be connected to the JF2 connector o
70. ry or metal objects from your body which are excellent metal conductors that can create short circuits and harm you if they come into contact with printed circuit boards or areas where power is present 4 2 Chapter 4 System Safety After accessing the inside of the system close the system back up and secure it to the rack unit with the retention screws after ensuring that all connections have been made 4 3 ESD Precautions A Electrostatic discharge ESD is generated by two objects with different electrical charges coming into contact with each other An electrical discharge is created to neutralize this difference which can damage electronic components and printed circuit boards The following measures are generally sufficient to neutralize this difference before contact is made to protect your equipment from ESD Use a grounded wrist strap designed to prevent static discharge Keep all components and printed circuit boards PCBs in their antistatic bags until ready for use Touch a grounded metal object before removing any board from its antistatic bag Do not let components or PCBs come into contact with your clothing which may retain a charge even if you are wearing a wrist strap Handle a board by its edges only do not touch its components peripheral chips memory modules or contacts When handling chips or modules avoid touching their pins Put the serverboard and peripher
71. s for rack installation The only difference in the installation procedure will be the positioning of the rack brackets to the rack They should be spaced apart just enough to accommodate the width of the telco rack Figure 2 4 Installing the Server into a Telco Rack 2 6 Chapter 2 Server Installation 2 5 Checking the Serverboard Setup After you install the 6013P 8 in the rack you will need to open the unit to make sure the serverboard is properly installed and all the connections have been made 1 Accessing the inside of the 6013P 8 see Figure 2 5 First release the retention screws that secure the unit to the rack Grasp the two handles on either side and pull the unit straight out until it locks you will hear a click Next depress the two buttons on the top of the chassis to release the top cover There is a large rectangular recess in the middle front of the top cover to help you push the cover away from you until it stops You can then lift the top cover from the chassis to gain full access to the inside of the server 2 Check the CPUs processors You should have one or two processors already installed into the serverboard Each processor needs its own heatsink See Chapter 5 for instructions on processor and heatsink installation 3 Verify the proper CPU clock ratio setting If the CPU speed is not automatically detected you will need to set the correct speed with the BIOS Setup
72. sable Watch Dog Timer Enable Disable Jumper Settings P JP37 The Watch Dog jumper located on Jumper JP37 allows you to enable or dis Position Definition o able the Watch Dog feature The Cibsed S default position is open to disable the Watch Dog timer When en abled Watch Dog can reboot your PC if an application is hung up or the system goes down See the table on the right for jumper set tings 5 20 Chapter 5 Advanced Serverboard Setup 5 10 Onboard Indicators GLAN1 GLAN2 LEDs 1 Gb LAN Right LED Indicator The Ethernet ports located beside LED u the VGA port have two LEDs UR DIESEN See the table on the right for the Green 100 MHz Orange 1GHz functions associated with these LEDs On each Gb LAN port the yellow LED indicates activity while the other LED may be green or ange or off to indicate the speed of the connection 5 21 SUPERSERVER 6013P 8 User s Manual 5 11 Floppy Hard Disk Drive and SCSI Connections Note the following when connecting the floppy and hard disk drive cables The floppy disk drive cable has seven twisted wires A red mark on a wire typically designates the location of pin 1 A single floppy disk drive ribbon cable has 34 wires and two connectors to provide for two floppy disk drives The connector with twisted wires always connects to drive A and the connector that does not have twisted wires always connects to drive B
73. see the following display Power setting options are displayed by highlighting the setting using the arrow keys and pressing lt Enter gt All Power BIOS settings are described in this section Phoenix BIOS Setup Utility Main Advanced Security Power Boot Exit Item Specific Help ACPI Mode Power Savings Enabled Customized Standby Timeout Oft Auto Suspend Timeout Off Resume On Time Off Resume Time 00 00 00 Resume on Modem Ring Off F1 Help Tl select Item Change Values F9 Setup Defaults Esc Exit Select Menu Enter Select gt Sub Menu F10 Save and Exit ACPI Mode Use the setting to determine if you want to employ ACPI Advanced Configuration and Power Interface power management on your system Power Savings This setting sets the degree of power saving for the system The options are Disabled Customized Maximum Power Savings and Maximum Performance Customized allows you to alter the other two modes 7 15 SUPERSERVER 6013P 8 Manual Standby Timeout Use this setting to specify the period of system inactivity to transpire before entering the standby state Options are Off 16 sec 32 sec 48 sec 1 min 2 min 4 min and 8 min Auto Suspend Timeout Use this setting to specify the period of system inactivity to transpire before entering the suspend state Options are Off 5 min 10 min 15 min 20 min 30 min 40 min and 60 min Resume on Time Select either Off or
74. selected by choos ing the appropriate text from the main BIOS Setup screen All displayed text is described in this section although the screen display is often all you need to understand how to set the options see on next page When you first power on the computer the PhoenixBIOS is immediately activated While the BIOS is in control the Setup program can be activated in one of two Ways 1 By pressing Delete immediately after turning the system on or 2 When the message shown below appears briefly at the bottom of the screen during the POST Power On Self Test press the Delete key to activate the main Setup menu Press the Delete key to enter Setup 7 3 Main BIOS Setup All main Setup options are described in this section The main BIOS Setup screen is displayed below Use the Up Down arrow keys to move among the different settings in each menu Use the Left Right arrow keys to change the options for each setting Press the Esc key to exit the CMOS Setup Menu The next section describes in detail how to navigate through the menus Items that use submenus are indicated with the f icon With the item highlighted press the Enter key to access the submenu 7 2 Chapter 7 BIOS Main BIOS Setup Menu Phoenix BIOS Setup Utility Advanced Security Item Specific Help System Time 16 19 20 System Date 02 02 02 Legacy Diskette A 1 44 1 25 MB Legacy Diskette B Not Instal
75. splays whether a supervisor password has been entered for the system Clear means such a password has not been used and Set means a supervisor password has been entered for the system User Password Is This displays whether a user password has been entered for the system Clear means such a password has not been used and Set means a user password has been entered for the system 7 13 SUPERSERVER 6013P 8 Manual Set Supervisor Password When the item Set Supervisor Password is highlighted hit the lt Enter gt key When prompted type the Supervisor s password in the dialogue box to set or to change supervisor s password which allows access to BIOS Set User Password When the item Set User Password is highlighted hit the lt Enter gt key When prompted type the user s password in the dialogue box to set or to change the user s password which allows access to the system at boot up Password on Boot This setting allows you to require a password to be entered when the system boots up Options are Enabled password required and Disabled password not required Fixed Disk Boot Sector This setting may offer some protection against viruses when set to Write Protect which protects the boot sector on the hard drive from having a virus written to it The other option is Normal 7 14 Chapter 7 BIOS 7 6 Power Choose Power from the Phoenix BIOS Setup Utility main menu with the arrow keys You should
76. stantly informed of the overall status of the system as well as the activity and health of specific components There are also two buttons on the chassis control panel and an on off switch on the power supply This chapter explains the meanings of all LED indicators and the appro priate response you may need to take 3 2 Control Panel Buttons There are two push button buttons located on the front of the chassis These are in order from left to right a reset button and a power on off button e RESET The reset switch reboots the system e POWER This is the main power switch which is used to apply or turn off the main system power Turning off system power with this button removes the main power but keeps standby power supplied to the system SUPERSERVER 6013P 8 User s Manual 3 3 Control Panel LEDs The control panel located on the front of th SC813S chassis has five LEDs These LEDs provide you with critical information related to different parts of the system This section explains what each LED indicates when illuminated and any corrective action you may need to take e OVERHEAT Indicates an overheat condition in the chassis This may be caused by cables obstructing the airflow in the system or the ambient room temperature being too warm You should also check to make sure that the chassis cover is installed and that all fans are present and operat ing normally Finally check the air seals for damage The air seals are
77. t figure in this chapter for connector locations IDE Device Cables IDE 1 and IDE 2 Floppy Drive Cable JP7 Ultra320 LVD SCSI Cables JA1 and JA2 Control Panel Cable JF2 see next page Connecting Power Cables The X5DPR 8G2 has a 20 pin primary power supply connector designated ATX Power for connection to the ATX power supply Connect the appro priate connector from the power supply to the ATX Power connector to supply power to the serverboard See the Connector Definitions section in this chapter for power connector pin definitions In addition the 8 pin header connector included with your power supply must be connected to the PWR SEC connection J15 SUPERSERVER 6013P 8 User s Manual Connecting the Control Panel JF2 contains header pins for various front control panel connectors See Figure 5 3 for the pin locations of the various front control panel buttons and LED indicators Please note that even and odd numbered pins are on opposite sides of each header All JF2 wires have been bundled into single ribbon cable to simplify their connection Make sure the red wire plugs into pin 1 as marked on the serverboard The other end connects to the Control Panel printed circuit board located just behind the system status LEDs in the chassis See the Connector Definitions section in this chapter for details and pin descriptions of JF2 Figure 5 3 Front Control Panel Header Pins JF2 20 19
78. ted on pins 5 and 6 of JF2 B Refer to the table on the right for x pin definitions This only applies 6 GND to redundant power supplies and So does not apply to the 6013P 8 Reset Button The Reset Button connection is lo Reset Pin Definitions cated on pins 3 and 4 of JF2 At JF2 tach it to the hardware reset Pin Number Definition switch on the computer case 3 Reset Refer to the table on the right for e pin definitions 5 13 SUPERSERVER 6013P 8 User s Manual Power Button Power Button Connector Pin Definitions The Power Button connection is JF2 Pin located on pins 1 and 2 of JF2 Number Definition 1 PW_ON Momentarily contacting both pins E Gradina will power on off the system This button can also be configured to function as a suspend button see the Power Button Mode setting in BIOS To turn off the power when set to suspend mode de press the button for at least 4 seconds Refer to the table on the right for pin definitions Universal Serial Bus USBO 1 Universal Serial Bus Pin Definitions USBO USB1 Two Universal Serial Bus ports pin scs PME m Number Definition Number Definition are located beside the PS 2 key 1 45V 1 5V r 2 Po 2 Po board mouse ports USBO is the 3 Pos 3 P4 bottom connector and USB1 is the Ground i4 Ground 5 N A 5 Key top connector See the table on the right for pin definitions Extra Univers
79. ter when adding or removing processors or main memory and when reconfiguring the serverboard Chapter 6 Advanced Chassis Setup Refer to Chapter 6 for detailed information on the 1U SC813S rackmount server chassis You should follow the procedures given in this chapter when installing removing or reconfiguring SCSI or peripheral drives and when replacing the sys tem power supply unit and cooling fans Chapter 7 BIOS The BIOS chapter includes an introduction to BIOS and provides detailed information on running the CMOS Setup Utility Appendix A BIOS POST Messages Appendix B BIOS POST Codes Appendix C System Specifications Preface Notes SUPERSERVER 6013P 8 Manual Table of Contents Preface About This Manual 2 cnr ertet ttti entere et iii Manual organizatlolia ameet e ette are Eee tnter heo ite escis iii Chapter 1 Introduction to the SuperServer 6013P 8 1 1 Overview wa Tl 1 2 Serverboard Features sse 1 2 13 Server Chassis Features oet meri nera eer fes 1 5 1 4 Contacting SuperMicro Liner rere etre tes 1 7 Chapter 2 Server Installation NEMO PER et 2 1 2 2 Unpacking the SuperServer 6013P 8 sssseeeeneen 2 1 2 9 Preparing for Set p erstehen apia riagi ee ko een 2 1 Choosing a Setup Location iut ei treat 2 2 Rack Precautions Server Precaltioris 3 nerit eee wen rerit eri cote P REST 2 4 Installing the SuperServer 6013P 8
80. the error was detected System RAM Failed at offset nnnn System RAM failed at offset nnnn of in the 64k block at which the error was detected Extended RAM Failed at offset nnnn Extended memory not working or not configured properly at offset nnnn System battery is dead Replace and run SETUP The CMOS clock battery indicator shows the battery is dead Replace the battery and run Setup to reconfigure the system A 1 SUPERSERVER 6013P 8 Manual System CMOS checksum bad Default configuration used System CMOS has been corrupted or modified incorrectly perhaps by an application program that changes data stored in CMOS The BIOS installed Default Setup Values If you do not want these values enter Setup and enter your own values If the error persists check the system battery or contact your dealer System timer error The timer test failed Requires repair of system board Real time clock error Real Time Clock fails BIOS hardware test May require board repair Check date and time settings BIOS found date or time out of range and reset the Real Time Clock May require setting legal date 1991 2099 Previous boot incomplete Default configuration used Previous POST did not complete successfully POST loads default values and offers to run Setup If the failure was caused by incorrect values and they are not corrected the next boot will likely fail On systems with control of wait states improper Setup settings ca
81. utility See the CPU Frequency Ratio settings in BIOS Chapter 7 for setting the proper CPU speed Most processor speeds are automatically detected so this step should be un necessary 4 Check the system memory Your 6013P 8 server system may have come with system memory already installed Make sure all DIMMs are fully seated in their slots For details on adding system memory refer to Chapter 5 5 Installing add on cards If desired you can install add on cards to the system See Chapter 5 for details on installing PCI add on cards 2 7 SUPERSERVER 6013P 8 Manual Figure 2 5 Accessing the Inside of the SuperServer 6013P 8 with optional front bezel shown 6 Check all cable connections and airflow Make sure all power and data cables are properly connected and not blocking the chassis airflow See Chapter 5 for details on cable connec tions Also check the air seals for damage The air seals are located under the blower fan and beneath the frame cross section that sepa rates the drive bay area from the serverboard area of the chassis 2 8 Chapter 2 Server Installation 2 6 Checking the Drive Bay Setup Next you should check to make sure the peripheral drives and the SCSI drives and SCSI backplane have been properly installed and all connections have been made 1 Accessing the drive bays All drives are accessable from the front of the server For servicing the CD ROM and floppy drives you
82. will need to remove the top chassis cover The SCSI disk drives can be installed and removed from the front of the chassis without removing the top chassis cover 2 CD ROM and floppy disk drives A slim CD ROM and a floppy drive should be preinstalled in your server Refer to Chapter 6 if you need to reinstall a CD ROM and or floppy disk drive to the system 3 Check the SCSI disk drives Depending upon your system s configuration your system may have one or more drives already installed If you need to install SCSI drives please refer to Chapter 6 4 Check the airflow Airflow is provided by two heavy duty 10 cm blower fans The system component layout was carefully designed to direct sufficient cooling air flow to the components that generate the most heat Note that all power and data cables have been routed in such a way that they do not block the airflow generated by the fans 5 Supplying power to the system The last thing you must do is to provide input power to the system Plug the power cord from the power supply unit into a high quality power strip that offers protection from electrical noise and power surges It is recommended that you use an uninterruptible power supply UPS 2 9 SUPERSERVER 6013P 8 Manual Notes Chapter 3 System Interface Chapter 3 System Interface 3 1 Overview There are several LEDs on the chassis control panel as well as others on the SCSI drive carriers to keep you con
83. wn on the DIMM module until it snaps into place in the slot Repeat for all modules see step 1 above 4 When installing modules into the two Bank 2 slots you will need to remove the power supply due to space constraints SUPERSERVER 6013P 8 User s Manual Memory Support The X5DPR 8G2 only supports ECC registered DDR266 200 PC2100 1600 memory If you are using 533 MHz FSB processors you should use DDR266 SDRAM If you are using 400 MHz FSB processors you may use either DDR266 or DDR200 SDRAM You should not mix DIMMs of different sizes and speeds See Figures 5 5a and 5 5b for installing and removing memory modules Figure 5 5a Side View of DIMM Installation into Slot Release s Note Notch should align with the receptive point on the slot To Install Insert module vertically and press down until it snaps into place Pay attention to the bottom notch To Remove Use your thumbs to gently push each release tab outward to free the DIMM from the slot Figure 5 5b Top View of DIMM Slot Top View of DDR Slot U L Release Tab Release Tab Chapter 5 Advanced Serverboard Setup 5 6 Adding PCI Cards 1 PCI slots The X5DPR 8G2 has one 64 bit 133 MHz PCI X slot for a full length standard PCI card and one slim 64 bit 66 MHz PCI slot The 64 bit 133 MHz PCI X slot should have a butterfly riser card installed which can accept one stand