Home

Enterasys 4-port Serial WAN (ER16-SERC-04

image

Contents

1. Refer to the Enterasys X Pedition Command Line Interface Reference Manual for details Hotswap You may install this module into a live system without powering off the device However you may not remove an active module from a live system except under the following conditions Press the Hotswap button The Online LED will turn off and the Offline LED will turn on OR Enter the following from the CLI and click enter Enable gt System gt Hotswap gt Out gt Slot gt The Online LED will turn off and the Offline LED will turn on Instructions CAUTION Before performing any upgrade or installation ensure that you are properly grounded to avoid electrostatic discharge The switch must be powered off before installing or replacing any module 1 Ifacoverplate is installed in the slot where you will install the ER16 SERC 04 AA remove the coverplate loosen the screws on the ejectors until the screws pop out then open the ejectors and pull out the plate 2 Open the ejectors at the top and bottom of the ER16 SERC 04 AA 3 Align the metal backpanel with the card guides at the top and the bottom of the slot opening as shown in Figure 1 ER16 SERC 04 AA not the circuit card is between the card NOTE Make sure that the metal backpanel of the guides Check both the upper and lower tracks 4 Slide the ER16 SERC 04 AA all the way into the slot firmly but gently pressing to ensure that the pin
2. NOTICE Enterasys Networks and its licensors reserve the right to make changes in specifications and other information contained in this document without prior notice The reader should in all cases consult Enterasys Networks to determine whether any such changes have been made The hardware firmware or software described in this manual is subject to change without notice IN NO EVENT SHALL ENTERASYS NETWORKS AND ITS LICENSORS BE LIABLE FOR ANY INCIDENTAL INDIRECT SPECIAL OR CONSEQUENTIAL DAMAGES WHATSOEVER INCLUDING BUT NOT LIMITED TO LOST PROFITS ARISING OUT OF OR RELATED TO THIS MANUAL OR THE INFORMATION CONTAINED IN IT EVEN IF ENTERASYS NETWORKS AND ITS LICENSORS HAVE BEEN ADVISED OF KNOWN OR SHOULD HAVE KNOWN THE POSSIBILITY OF SUCH DAMAGES Enterasys Networks Inc 35 Industrial Way Rochester NH 03866 5005 2001 by Enterasys Networks Inc All Rights Reserved Printed in the United States of America Order Number 9033749 September 2001 X Pedition and Enterasys Networks are registered trademarks of Enterasys Networks or its licensors All other product names mentioned in this manual may be trademarks or registered trademarks of their respective companies FCC NOTICE This device complies with Part 15 of the FCC rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause und
3. esired operation NOTE This equipment has been tested and found to comply with the limits for a class A digital device pursuant to Part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment uses generates and can radiate radio frequency energy and if not installed in accordance with the operator s manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause interference in which case the user will be required to correct the interference at his own expense WARNING Changes or modifications made to this device which are not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment INDUSTRY CANADA NOTICE This digital apparatus does not exceed the class A limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications Le pr sent appareil num rique n met pas de bruits radio lectriques d passant les limites applicables aux appareils num riques de la class A prescrites dans le R glement sur le brouillage radio lectrique dict par le minist re des Communications du Canada VCCI NOTICE This is a class A product based on the standard of the Voluntary Control Council for Interference by Informati
4. f FCC Part 15 CSA C108 8 EN 55022 EN 61000 3 2 EN 61000 3 3 VCCI V 3 EN 55024 89 336 EEC and AS NZS 3548 ER16 SERC 04 AA The ER16 SERC 04 AA Serial card provides wide area connectivity via 4 T1 E1 ports with compression These ports have the same switching and routing capabilities as those provided by the ethernet line cards The ports can switch at Layer 2 Layer 3 and Layer 4 and perform both destination based and flow based switching All ports are capable of bridging at Layer 2 switching IP IPX frames at Layer 3 and switching on Layer 4 flows SPECIFICATIONS Ports 4 Serial ports with compression up to 8MB per port ASIC Type AA Advanced ASIC DMAC IPP OPP Network Interfaces 60 Pin D shell supporting 2 serial ports per connector Physical Dimensions Size 52 9 cm H x 2 9 W x 40 1 D 20 9 in H x 1 15 W x 15 8 D Weight 2 72 kg 6 0 lbs Power Consumption BTU hr 146 35 AC Volt Amps 43 31 Temperature Operating 32 to 104 F 0 to 40 C Storage 22 to 194 F 30 to 90 C Humidity 5 to 95 non condensing CONNECTIVITY GUIDELINES Table 1 Recommended Cable Types and Specifications Cable Type Max Length Connector Serial V 35 EIA 530 EIA 449 X 21 60 Pin D Shell LEDs Table 2 LED Indicators LED Condition Status Online 2 Green The unit is operational and functioning properly Offline 2 Amber The unit is not operational You may remove the unit from the cha
5. on Technology Equipment VCCI If this equipment is used in a domestic environment radio disturbance may arise When such trouble occurs the user may be required to take corrective actions COM ARLERESERMEAEMM RR VCCI OFF CHD DVIRZATRRNEE CT TOREA KERETET S Ei HHMI LC EMHVET COBRCLEAAMBIEHRERST SZLIBRENSTEMHOVET CLASS A ITE NOTICE WARNING This is a class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures DECLARATION OF CONFORMITY Application of Council Directive s 89 336 EEC 73 23 EEC Manufacturer s Name Enterasys Networks Inc Manufacturer s Address 35 Industrial Way PO Box 5005 Rochester NH 03867 European Representative Name Mr Jim Sims European Representative Address Enterasys Networks Ltd Nexus House Newbury Business Park London Road Newbury Berkshire RG14 2PZ England Conformance to Directive s Product Standards EC Directive 89 336 EEC EC Directive 73 23 EEC EN 55022 EN 55024 EN 60950 EN 60825 Equipment Type Environment Networking Equipment for use in a Commercial or Light Industrial Environment Enterasys Networks Inc declares that the equipment packaged with this notice conforms to the above directives AGENCY STANDARDS Safety Meets the requirements of UL 1950 CSA C22 2 No 950 EN 60950 IEC 950 73 23 EEC and EN 608235 Electromagnetic Compatibility Compliant with the requirements o
6. s on the back of the module are completely seated in the backplane 5 To lock the ER16 SERC 04 AA into the slot close the ejectors Using a flathead screwdriver tighten the screw on each ejector Figure 1 Install the ER16 SERC 04 AA Rotate ejector to lock in place Circuit Card Metal Backpanel Card OFFLINE al HOT O swap TROUBLESHOOTING Proper Boot Sequence Firmware loads The control module for the chassis should indicate that the ER16 SERC 04 AA was detected and is operating correctly The Online LED will turn on and remain lit no other LEDs should illuminate during module power up Common Errors The ER16 SERC 04 AA is not inserted properly or seated completely in the chassis Connectors for the connected lines are not seated properly Helpful CLI Commands for Debugging e System show hardware System show version Port show port status se x y where x is the chassis slot that contains the line card and y is a specific port number on the card e System show bootlog ADDITIONAL INFORMATION For additional information about installing this module or to learn more about what capabilities are included in the firmware release you are using visit the Enterasys Networks web site Getting Help For additional support related to the Common CLI syntax or this doc
7. ssis Tx 4 Amber A frame was transmitted Rx 4 Amber A frame was received Link 4 Green A valid link is established on the port INSTALLING THE MODULE ELECTRICAL HAZARD Only qualified personnel should perform installation procedures Handling the Module CAUTION The ER16 SERC 04 AA is easily damaged by electrostatic discharge To prevent electrostatic damage observe the following guidelines Do not remove the module from its packaging until you are ready to install it Do not touch any of the module s pins connectors or components Hold the module only by its edges or front panel Wear an anti static wristband connected to a suitable earth ground whenever handling the module Store or transport this module only in appropriate anti static packaging Equipment Checklist After unpacking the ER16 SERC 04 AA check the contents of the box to be sure you received the following items One ER16 SERC 04 AA module in anti static bag One disposable anti static wristband Tools This installation requires the following tool Flathead screwdriver Anti static wristband Preliminary Setup Firmware Image Requirements Version 8 3 0 0 or later CLI Setup Enter the following command at the CLI before implementing any configurations 1 Type the following from Enable mode to enter Configuration mode Enable gt Configure 2 You may now begin configuring ports on the ER16 SERC 04 AA
8. ument contact Enterasys Networks using one of the following methods World Wide Web http www enterasys com Phone 603 332 9400 Internet mail support enterasys com FTP fip ftp enterasys com Password your email address To acquire the latest image for http www enterasys com download this product and any available release notes Additional documentation http www enterasys com support manuals To send comments or suggestions concerning this document contact the Technical Writing Department via the following email address TechWriting enterasys com Please include the document Part Number in the email message Before contacting Enterasys Networks for technical support have the following information ready e Your Enterasys Networks service contract number A description of the failure A description of any action s taken to resolve the problem e g changing mode switches rebooting the unit The serial and revision numbers of all involved Enterasys Networks products in the network e A description of your network environment layout cable type etc Network load and frame size at the time of trouble if known ER16 SERC 04 AA Quick Start Web Site http www enterasys com 9033749 ENTERASYS NETWORKS n