Home
Emerson HF1160WW 60" Industrial White Ceiling Fan
Contents
1. Electrical Requirements Your new ceiling fan will require a grounded electrical supply line of 120 volts AC 60 Hz 15 amp circuit The outlet box must be securely anchored and capable of withstanding a load of at least 50 pounds A WARNING To reduce the risk of fire electric shock or personal injury mount fan to outlet box marked Acceptable for Fan Support of 50 Ibs or less and use screws supplied with outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt If your fan is to replace an existing ceiling light fixture turn electricity off at the main fuse box at this time and remove the existing light fixture A WARNING Turning off wall switch is not sufficient To avoid possible electrical shock be sure electricity is turned off at the main fuse box before wiring All wiring must be in accordance with National and Local codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock Assembly Instructions CAUTION The blade assemblies must be mounted on the motor assembly so that the This Side Up label is visible at the top of the motor Figure 1 1 Install one blade assembly on the top of the motor assembly using two M6 1 0 x 12mm Phillips hex head screws two split lockwashers and two flat washers supplied Figur
2. WHEN ORDERING REPAIR PARTS ALWAYS GIVE THE FOLLOWING INFORMATION e PART NUMBER NAME OF ITEM PART DESCRIPTION e MODEL NUMBER The model number of your Fan will be found on a label attached to the top housing For repair parts phone 1 800 654 3545 Repair Parts 16 19 a g EMERSON Air comfort Products DIVISION OF EMERSON COMPANY 8100 W Florissant e St Louis MO 63136 Part No F40BP72720000 Printed in Taiwan 02 04 Form No BP7272
3. AN TO OBTAIN LIMITED WARRANTY SERVICE KEEP YOUR RECEIPT OR OTHER PROOF OF PURCHASE You can return the product to our factory or to your nearest authorized service center e To return the product to the factory obtain a return authorization and service identification tag by writing to Air Comfort Products Division of Emerson Company 8100 W Florissant Ave St Louis MO 63136 Include all model numbers shown on the product with your request e To return the product to an authorized service center call 1 800 654 3545 for the address of the nearest authorized service center You will be responsible for all insurance freight or other transportation charges to our factory or authorized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage What Is Not Covered The glass globes and light bulbs of your ceiling fan are not covered by this warranty This warranty also does not cover any defects malfunctions or failures caused by e Repairs by persons not authorized by Emerson Company e Use of parts or accessories not authorized by Emerson Company e Mishandling improper installation modifications or damage to your ceiling fan while in your possession or e Unreasonable use misuse abuse including failing to do reasonable and necessary maintenance and normal wear and tear Additionally this warranty and any implied warranty of merchantability or fitnes
4. READ AND SAVE THESE INSTRUCTIONS 60 Industrial Heat Fan Owner s Manual Model No HF1160BK 00 Net Weight 19 8 Lbs H F 1160WW 00 LIMITED WARRANTY What The Warranty Covers This warranty covers the motor and the other components and accessories of your Emerson ceiling fan against all defects in workmanship and materials You must be the original purchaser or user of the product to be covered What The Period Of Coverage Is As it applies to the motor this warranty will last for five years from the date you purchased your ceiling fan All other components and accessories are covered by this warranty for one year from the date you purchased your ceiling fan ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE MADE WITH RESPECT TO COMPONENTS AND ACCESSORIES IS ALSO LIMITED TO ONE YEAR What Will Emerson Company Do To Correct Problems Emerson Company will replace a defective Emerson Air Comfort Ceiling Fan motor blade component or other accessory at no charge to you If repair of the motor or blades is not practical or possible within a reasonable time and no replacement can be provided Emerson Company will refund the actual purchase price of your fan We will ship the repaired product or replacement to you at no charge but you are responsible for all costs or removal reinstallation and shipping of the product to Emerson Company How Can You Get Service YOU MUST HAVE PROOF OF YOUR PURCHASE OF THE CEILING F
5. ches of slack in the safety cable before tightening the nuts Cut off the excess cable E 18 If a remote speed control is to be used refer to the Owners Manual included with the control for proper installation and wiring Eia After completing the installation restore the power and test run the fan NOTE When any solid state motor speed control is used a humming noise may be present in the fan on low speed This hum in no way affects the operation of the fan and is acceptable in most industrial installations Repair Parts Listing Part Numbers Model No Model No Description HF1160BK 00 HF1160WW 00 Hanger Ball Assembly 760750 46 760750 47 Consisting of Hanger Bracket Hanger Ball Downrod Parts Bag Containing 762499 762499 Wire Connector 3 Pin Clevis Clip Hairpin Nut Knurled 8 32 2 Lockwasher External Tooth 8 2 Stud Threaded 8 32 x 75 2 Screw Phillips Hex Head M6 1 0 x 12mm 7 Lockwasher Split 7 Washer Flat 7 Screw Pan Head Knurled M4 7 x 10mm 2 Lockwasher External Tooth M4 2 Wrench Setscrew Clamp Safety Wire 2 Screw Eye Cover Ceiling 762516 3 762516 15 Cover Motor 762494 762494 1 Capacitor 4 5 uF 762493 762493 Blade set of 3 762495 762495 1 Flange set of 3 762497 762497 1 Owner s Manual BP7272 BP7272 Before discarding packaging material be certain all parts have been removed HOW TO ORDER REPAIR PARTS
6. clip Figure 3 The clevis pin must go through the holes in the motor yoke It is critical that the clevis pin in the motor yoke is properly installed and the setscrews securely tightened Failure to verify that the pin and setscrews are properly installed could result in the fan falling A WARNING It is critical that the clevis pin in the motor coupling is properly installed and the setscrews securely tightened Failure to verify that the pin and setscrews are properly installed as shown in Figure 3 could result in the fan falling 7 Install two setscrews previously removed in Step 2 in the motor yoke Figure 3 While pulling up on the hanger ball securely tighten both setscrews using the setscrew wrench supplied NOTE The setscrews must be properly installed as described above or fan wobble could result 4 WARNING The fan must be hung with at least 10 of clearance from floor to blades Figure 4 A To AT LEAST 10 IOO FLOOR III Figure 4 A WARNING The outlet box and joist must be securely mounted and capable of supporting at least 50 Ibs Use only a U L outlet box listed as Acceptable for Fan Support of 50 Ibs or less A WARNING To reduce the risk of fire electric shock or personal injury mount fan to outlet box marked Acceptable for Fan Support of 50 Ibs or less and use screws supplied with outlet box Most outlet boxes commonly used
7. d electrician if in doubt The fan must be mounted with the fan blades at least 10 feet from the floor to prevent accidental contact with the fan blades Suitable for use with solid state speed controls Always properly connect the safety cable included with this fan follow the Installation Instructions section carefully The support beam or joist must be secure and capable of supporting at least 50 pounds Follow the recommended instructions for the proper method of wiring your ceiling fan If you do not know enough about electrical wiring have your fan installed by a licensed electrician WARNING To avoid fire shock or injury do not use an Emerson or any other brand of control not specifically approved for this fan WARNING This product is designed to use only those parts supplied with this product and or any accessories designated specifically for use with this product by Emerson Company Substitution of parts or accessories not designated for use with this product by Emerson Company could result in personal injury or property damage WARNING To Reduce the risk of personal injury do not bend the blade flange when installing the blade flanges balancing the blades or cleaning the fan Do not insert foreign objects in between rotating fan blades DATE CODE The date code of this fan may be found on the box stamped in ink on a white label You should record this data above and keep it in a safe place for fut
8. e 1 Repeat this procedure for the remaining two blade assemblies M6 1 0 x 12mm PHILLIPS HEX HEAD SCREW SPLIT LOCKWASHER SETSCREW 2 FLAT WASHER MOTOR BLADE YOKE ASSEMBLY LABEL B S N lt o 8 Ciis E MOTOR ASSEMBLY Figure 1 2 Using the setscrew wrench supplied remove the two setscrews from the top of the motor yoke Figure 1 Retain the setscrews for future use 3 Route the three 48 motor leads and the safety cable through the center hole in the motor cover Align the two holes in the motor cover with the threaded holes in the motor yoke and secure by installing two M4 7 x 10mm pan head knurled screws and two M4 external tooth lockwashers supplied Figure 2 M4 7 x 10mm PAN HEAD KNURLED SCREW M4 EXTERNAL TOOTH LOCKWASHER MOTOR COVER H Figure 2 4 Route the three motor leads and the safety cable through the center hole in the ceiling cover and position the ceiling cover over the motor yoke Figure 3 5 Separate untwist and unkink the three motor leads and the safety cable then route them through the hanger ball downrod assembly and seat the downrod in the motor yoke Figure 3 HANGER BALL DOWNROD ASSEMBLY CEILING COVER Figure 3 6 Align the clevis pin holes in the downrod with the holes in the motor yoke Install the clevis pin and secure with the hairpin
9. ectrical wires are completely inside the outlet box and not pinched between the ceiling cover and the ceiling C 16 Pass the end of the safety cable through the two Accessories cable clamps supplied Figure 10 Pass the end of the safety cable through the eye screw and 1 Ceiling Fan Controls see store or catalog then back through the two cable clamps 2 Downrod Extension Kits see store or catalog The use of any other control not specifically SS 5 10 J gt TO FAN approved for this fan could result in fire shock and personal injury CABLE CLAMP EYE SCREW 4 WARNING Figure 10 CAUTION It is important to note the proper This product is designed to use only those parts h llati aai f th bl l supplied with this product and or any accessories installation position of the cable clamps as designated specifically for use with this product by illustrated in Figure 10 TO obtain maximum Emerson Company Substitution of parts or holding power install U bolt section of clip on accessories not designated for use with this product dead or short end of cable and saddle on long end by Emerson Company could result in personal injury or property damage of cable Improper installation reduces the efficiency of the connection by as much as 40 percent J17 After verifying that the cable clamps are positioned properly on the safety cable tighten the nuts on the U bolts Leave one or two in
10. er off at service panel and lock service panel disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a warning device such as a tag to the service panel Be careful of the fan and blades when cleaning painting or working near the fan Always turn off the power to the ceiling fan before servicing Suitable for use with solid state speed controls Do not bend the blade flanges when installing the blades balancing the blades or cleaning the fan Do not insert foreign objects in between the rotating blades Additional Safety Instructions for Installation To avoid possible shock be sure electricity is turned off at the fuse box before wiring and do not operate fan without blades All wiring must satisfy National and Local Electrical Codes Use the National Electrical Code if Local Codes do not exist The ceiling fan must be grounded as a precaution against possible electrical shock Electrical installation should be made or approved by a licensed electrician The outlet box and joist must be securely mounted and capable of reliably supporting at least 50 pounds Use only U L outlet boxes listed as Acceptable for Fan Support of 50 Ibs or less and use the mounting screws provided with the outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualifie
11. for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt 8 Securely attach the hanger bracket to the outlet box using the two screws supplied with the outlet box Figure 5 A WARNING Hanger bracket must seat firmly against outlet box If the outlet box is recessed remove wall board until bracket contacts box If bracket and or outlet box are not securely attached the fan could wobble or fall TWO SCREWS SUPPLIED WITH OUTLET BOX HANGER BRACKET Figure 5 9 Screw the eye screw supplied into the joist 7 inches from the center of the ceiling outlet box Figure 6 Figure 6 10 Carefully lift the fan and seat the hanger ball downrod assembly on the hanger bracket that was just attached to the outlet box Figure 7 Be sure the groove in the ball is lined up with the tab on the hanger bracket Figure 5 4 WARNING Failure to seat tab in groove could cause damage to electrical wires and possible shock or fire hazard NOTE CEILING COVER o 7 SUPPLY WIRES AND ey FAN WIRES aren i l Pag geen OUTLET FOR CLARIT N ae BOX HANGER BRACKET HANGER BALL DOWNROD A WARNING To avoid possible fire or shock do not pinch wires between the hanger ball downrod assembly and hanger bracket If you feel that you do not have enough electrical wiring knowledge or experience have your fan i
12. nstalled by a licensed electrician A WARNING To avoid possible electrical shock be sure electricity is turned off at the main fuse box before wiring NOTE If you are not sure if the outlet box is grounded contact a licensed electrician for advice as it must be grounded for safe operation jt Connect the green grounding wire from the hanger ball the green grounding wire from the hanger bracket and the green grounding wire from the fan to the grounding conductor of the supply this may be a bare wire or wire with green colored insulation Securely connect wires with wire connectors supplied Figure 8 BLACK amp WHITE SUPPLY SUPPLY HOT NEUTRAL BLACK FAN WIRE A sine GREEN WIRE FIA FAN WIRE GROUND FROM FAN BoE SUPPLY GROUND Xo f WIRE HANGER GREEN WIRE X BRACKET GROUND FROM HANGER BALL THREADED GREEN WIRE GROUND STUD 2 FROM HANGER BRACKET LISTED WIRE Figure 8 CONNECTOR 3 12 Securely connect the fan motor white wire to the supply white neutral wire using wire connector supplied Figure 8 Securely connect the fan motor black wire to the supply black hot wire using wire connector supplied Figure 8 After connections have been made turn leads upward and carefully push the leads into the outlet box with the wires spread apart and the white and green leads on one side of the outlet box and the black leads on the other side of the outlet bo
13. s for a particular purpose are voided when e The original purchaser or user ceases to own the product or e The fan is moved from its original point of installation This warranty is only valid within the 50 states of the United States and the District of Columbia No other written or oral warranties apply and no employee agent dealer or other person is authorized to give any warranties on behalf of Emerson Company REPAIR REPLACEMENT OR A REFUND ARE THE EXCLUSIVE REMEDIES AVAILABLE UNDER THIS WARRANTY AND EMERSON IS NOT RESPONSIBLE FOR DAMAGES OF ANY KIND INCLUDING INCIDENTAL AND CONSEQUENTIAL DAMAGES Incidental damages include but are not limited to such damages as loss of time and loss of use Consequential damages include but are not limited to the cost of repairing or replacing other property which was damaged if this product does not work properly How State Law Relates To The Warranty Some states do not allow the exclusion or limitation of incidental or consequential damages so the above exclusion or limitation may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state Part No F40BP72720000 Form No BP7272 A WARNING WARNING To avoid fire shock and serious personal injury follow these instructions Safety Instructions Read your owner s manual carefully and keep it for future reference Before servicing or cleaning unit switch pow
14. ure use Checking Contents of Package 1 Unpack the items carefully to avoid damage to any of the components Check to see that you have received the following parts NOTE If you are uncertain of part description refer to the exploded view illustration Fan motor assembly One ceiling cover One motor cover Three fan blades assemblies One hanger bracket One hanger ball downrod assembly One loose parts bag containing One clevis pin One hairpin clip Three wire connectors Seven M6 1 0 x 12mm Phillips hex head screws 5 Seven split lockwashers 6 Seven flat washers 7 Two M4 7 x 10mm pan head knurled screws 8 9 ea oaoo0m APUN Two M4 external tooth lockwashers Two 8 32 knurled nuts 10 Two 8 external tooth lockwashers 11 Two 8 32 x 75 threaded studs 12 Two safety wire clamps 13 One eye screw 14 One setscrew wrench NOTE Intermixing blades between fans can cause excessive wobble Keep blades in original sets of three A WARNING Do not install or use fan if any part is damaged or missing Call Toll Free 1 800 654 3545 A WARNING This product is designed to use only those parts supplied with this product and or any accessories designated specifically for use with this product by Emerson Company Substitution of parts or accessories not designated for use with this product by Emerson Company could result in personal injury or property damage
15. x A WARNING Check to see that all connections are tight including ground and that no bare wire is visible at the wire connectors except for the ground wire Do not operate fan until blades are in place Noise and fan damage could result 13 Screw the two 3 4 threaded studs supplied into the tapped holes in the hanger bracket Figure 8 14 Lift the ceiling cover up to the threaded studs and turn until studs protrude through the holes in the ceiling cover Figure 9 15 Secure the ceiling cover in place by sliding lockwashers over the threaded studs and installing the two knurled knobs supplied Figure 9 Tighten the knurled knobs securely until the ceiling cover fits snugly against the ceiling Your fan is now wired to be turned on and off from the wall switch Maintenance IMPORTANT CARE INSTRUCTIONS CEILING for your Ceiling Fan COVER SAFETY CABLE Periodic cleaning of your new ceiling fan is the only maintenance that is needed When cleaning use only a soft brush or lint free cloth to avoid scratching the finish THREADED STUDS 2 8 LOCKWASHER KNURLED KNOB Figure 9 4 WARNING 4 WARNING To avoid possible fire or shock make sure that the Abrasive cleaning agents are not required and should be avoided to prevent damage to finish Do not use water when cleaning your ceiling fan It could damage the motor or the blades and create the possibility of an electrical shock el
Download Pdf Manuals
Related Search
Related Contents
GUIDE D`UTILISATION de ponçeuse à disque 2 po (50 mm Wireless Modbus I/O LG Electronics 26LK330 Flat Panel Television User Manual 取扱説明書 10-808型 取扱説明書 保証書付 ガステーブルコンロ Doro HearEasy 310ra Copyright © All rights reserved.
Failed to retrieve file