1. One ER16 FDDI 02 module in anti static bag One disposable anti static wristband Tools This installation requires the following tools Anti static wristband Phillips screwdriver mE Flathead screwdriver Preliminary Setup Firmware Image Requirements Version 8 3 0 0 or later Preparing the Module Before installing the module you must install at least one of the following XP FPHYs purchased separately XP FPHY 01 XP FPHY 02 or XP FPHY 09 Connector Pin Assignments The connector pins are assigned as follows Table 5 DB9 RS232 Console Port Pin Assignments Pin Connection 1 TX 2 TX 3 Unused 4 Unused 5 Unused 6 Unused 7 RX 8 RX Hotswap You may install this module into a live system without powering off the device However do not remove an active module from a live system except under the following conditions Press the Hotswap button The Online LED will turn off and the Offline LED will turn on OR Enter the following from the CLI and click enter Enable gt System gt Hotswap gt Out gt Slot gt The Online LED will turn off and the Offline LED will turn on Instructions CAUTION Before performing any upgrade or installation ensure N that you are properly grounded to avoid electrostatic discharge The switch must be powered off before installing or replacing any module 1 Open the ejectors at the top and bottom of the module
2. If a cover plate is installed in the slot where you will install the ER16 FDDI 02 module remove the cover plate loosen the screws on the ejectors until the screws pop out then open the ejectors and pull out the plate 2 Align the metal backpanel of the module with the card guides at the top and the bottom of the slot opening as shown in Figure 1 hasta NOTE Make sure that the metal backpanel of the ER16 FDDI 02 not the circuit card is between the card guides Check both the upper and lower tracks 3 Slide the ER16 FDDI 02 all the way into the slot firmly but gently pressing to ensure that the pins on the back of the module are completely seated in the backplane 4 To lock the ER16 FDDI 02 into the slot close the ejectors Using a flathead screwdriver tighten the screw on each ejector Figure 1 Install the FDDI Module i Rotate ejector to lock in place a Circuit Card Metal Backpanel Guides jo Cage ONLINE lt o I OC OFFLINE X K OFFLINE O HOT Tol SWAP TROUBLESHOOTING Proper Boot Sequence Firmware loads The LEDs on Port 1 light in the following order A B P S Rx and Tx After the Tx LED lights all LEDs turn off and the online LED turns green Diagnostic messages display for each line card Status lights on line cards go online Link lights activate
3. for connected lines Common Errors Ensure the ER16 is powered up Ensure that the device attached to the module is powered up and operating correctly Ensure that the module is properly seated in the slot Check the connectors on both ends of the cable to be sure they are properly engaged When attaching fiber cable to an SC type port be sure the plug clicks into place to ensure that it is properly seated e If you are using fiber optic cable with an ST type connector in conjunction with an SC ST port converter try switching the TX and RX connectors Helpful CLI Commands for Debugging System show hardware System show version System show bootlog ADDITIONAL INFORMATION For additional information about installing this module or to learn more about what capabilities are included in the firmware release you are using visit the Enterasys Networks web site Getting Help For additional support related to the Common CLI syntax or this document contact Enterasys Networks using one of the following methods World Wide Web http www enterasys com Phone 603 332 9400 Internet mail support enterasys com FTP fip ftp enterasys com Password your email address To acquire the latest image for http www enterasys com download this product and any available release notes Additional documentation http www enterasys com support manuals To send comments or suggestions concerning this document contac
4. ohm 100 m 328 ft RJ45 UTP XP FPHY 02 Multi mode Fiber 62 5 125 2 km 1 24 mi SC XP FPHY 01 Single mode Fiber 10 125 30 km 18 64 mi SC XP FPHY 09 OPTICS Table 2 Receiver Transmitter Receiver Sensitivity Transmit Power MMF SMF MMF SMF Minimum 34 dBm 33 dBm Minimum 20 dBm 8 dBm Maximum 31 dBm 3 dBm Maximum 14 dBm 3 dBm Table 3 Links Link Power Budget MMF 11 dB SMF gt 10 dB LEDs Table 4 LED indicators LED Condition Status Rx Off No activity Flashing Yellow Activity Red Diagnostic failure Tx Off No activity Flashing Green Activity Blinking Yellow Port on standby Red Diagnostic failure Port LEDs A B P S INSTALLING THE MODULE ELECTRICAL HAZARD Only qualified personnel should perform installation procedures Handling the Module CAUTION The ER16 FDDI 02 is easily damaged by electrostatic discharge To prevent electrostatic damage observe the following guidelines Do not remove the module from its packaging until you are ready to install it Do not touch any of the module s pins connectors or components Hold the module only by its edges or front panel Wear an anti static wristband connected to a suitable earth ground whenever handling the module e Store or transport this module only in appropriate anti static packaging Equipment Checklist After unpacking the ER16 FDDI 02 check the contents of the box to be sure you received the following items
5. 15 CSA C108 8 EN 55022 VCCI Class A EN 50082 1 and 89 336 EEC ER16 FDDI 02 The ER16 FDDI 02 module supports high performance translation from Ethernet Fast Ethernet Gigabit Ethernet and ATM to FDDI as well as connectivity between FDDI modules IP Fragmentation support allows the module to fragment FDDI frames into multiple smaller Ethernet frames MTU path discovery support allows the module to transport the maximum size of packet to its end destination FDDI full duplex support is available for point to point connections with only two stations on a FDDI ring that support full duplex The ER16 FDDI 02 module also supports the ring and DEC ring purger protocols an extension to the FDDI specification SPECIFICATIONS Ports 2 Port FDDI Base Module ASIC Type T Series Network Interfaces XP FPHY 01 MMF DAS XP FPHY 02 UTP SAS XP FPHY 09 SMF DAS Number of Flows Routes Up to 128 000 Layer 2 entries per port Up to 256 000 Layer 3 4 entries Queue Buffer Packet memory size 8MB Physical Dimensions Size 52 9 cm H x 5 5 W x 40 1 D 20 9 in H x 2 17 W x 15 8 D Weight 1 4 kg 3 0 Ibs Power Consumption BTU hr 203 14 AC Volt Amps 60 12 Temperature Operating 41 to 104 F 5 to 40 C Storage 22 to 164 F 30 to 73 C Humidity 5 to 90 non condensing CONNECTIVITY GUIDELINES Table 1 Recommended Cable Types and Specifications Cable Type Max Length Connector FDDI Copper Cat 3 4 5 100
6. NOTICE Enterasys Networks and its licensors reserve the right to make changes in specifications and other information contained in this document without prior notice The reader should in all cases consult Enterasys Networks to determine whether any such changes have been made The hardware firmware or software described in this manual is subject to change without notice IN NO EVENT SHALL ENTERASYS NETWORKS AND ITS LICENSORS BE LIABLE FOR ANY INCIDENTAL INDIRECT SPECIAL OR CONSEQUENTIAL DAMAGES WHATSOEVER INCLUDING BUT NOT LIMITED TO LOST PROFITS ARISING OUT OF OR RELATED TO THIS MANUAL OR THE INFORMATION CONTAINED IN IT EVEN IF ENTERASYS NETWORKS AND ITS LICENSORS HAVE BEEN ADVISED OF KNOWN OR SHOULD HAVE KNOWN THE POSSIBILITY OF SUCH DAMAGES Enterasys Networks Inc 35 Industrial Way Rochester NH 03866 5005 2001 by Enterasys Networks Inc All Rights Reserved Printed in the United States of America Order Number 9033744 September 2001 X Pedition and Enterasys Networks are registered trademarks of Enterasys Networks or its licensors All other product names mentioned in this manual may be trademarks or registered trademarks of their respective companies FCC NOTICE This device complies with Part 15 of the FCC rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause und
7. esired operation NOTE This equipment has been tested and found to comply with the limits for a class A digital device pursuant to Part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment uses generates and can radiate radio frequency energy and if not installed in accordance with the operator s manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause interference in which case the user will be required to correct the interference at his own expense WARNING Changes or modifications made to this device which are not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment INDUSTRY CANADA NOTICE This digital apparatus does not exceed the class A limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications Le pr sent appareil num rique n met pas de bruits radio lectriques d passant les limites applicables aux appareils num riques de la class A prescrites dans le R glement sur le brouillage radio lectrique dict par le minist re des Communications du Canada VCCI NOTICE This is a class A product based on the standard of the Voluntary Control Council for Interference by Informati
8. on Technology Equipment VCCI If this equipment is used in a domestic environment radio disturbance may arise When such trouble occurs the user may be required to take corrective actions COM ARLERESERMEAEMM RR VCCI OFF CHD DVIRZATRRNEE CT TOREA KERETET S Ei HHMI LC EMHVET COBRCLEAAMBIEHRERST SZLIBRENSTEMHOVET CLASS A ITE NOTICE WARNING This is a class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures DECLARATION OF CONFORMITY Application of Council Directive s 89 336 EEC 73 23 EEC Manufacturer s Name Enterasys Networks Inc Manufacturer s Address 35 Industrial Way PO Box 5005 Rochester NH 03867 European Representative Name Mr Jim Sims European Representative Address Enterasys Networks Ltd Nexus House Newbury Business Park London Road Newbury Berkshire RG14 2PZ England Conformance to Directive s Product Standards EC Directive 89 336 EEC EC Directive 73 23 EEC EN 55022 EN 55024 EN 60950 EN 60825 Equipment Type Environment Networking Equipment for use in a Commercial or Light Industrial Environment Enterasys Networks Inc declares that the equipment packaged with this notice conforms to the above directives AGENCY STANDARDS Safety Meets the requirements of UL 1950 CSA C22 2 No 950 EN 60950 IEC 950 and 73 23 EEC Electromagnetic Compatibility Compliant with the requirements of FCC Part
9. t the Technical Writing Department via the following email address TechWriting enterasys com Please include the document Part Number in the email message Before contacting Enterasys Networks for technical support have the following information ready Your Enterasys Networks service contract number A description of the failure A description of any action s taken to resolve the problem e g changing mode switches rebooting the unit The serial and revision numbers of all involved Enterasys Networks products in the network A description of your network environment layout cable type etc e Network load and frame size at the time of trouble if known 6 ER16 FDDI 02 Quick Start Web Site http www enterasys com 9033744 ENTERASYS NETWORKS n