Home

Fujioh FSR-3600 Kitchen Hood

image

Contents

1. Vertical Ducting WOOD SHIMS recessed bottom cabinets only 13 1 2 30 hood 16 1 2 36 hood 19 1 2 42 hood CABINET 6 1 4 ELECTRICAL 13 1 2 30 hood 16 1 2 36 hood 19 1 2 42 hood CABINET FRONT BOTTOM HOOD MOUNTING SCREWS 4 ACCESS HOLE CENTER LINE 4 1 4 Run house wiring between service panel and hood location Prepare the range hood 1 Remove the 7 round duct joint on the top plate of the body by removing 2 fixing screws Note Keep the screws for reusing later 2 Remove the Rectifier Baffle Panel by loosening the screws and dislocating its temporary fixing holes from the screws Note Use a screwariver if they are tight Rectifier Baffle Panel 3 Remove the fan case cover by removing 4 screws Bl In Case of 3 1 4 x10 Vertical Discharge Mount the supplied 3 1 4 x10 rectangular duct joint on the top plate with 4 screws 2 pieces removed in Step 4 1 the others supplied Then attach the supplied soft tape around the duct joint E In Case of 7 Round Vertical Discharge First remove half cut circular part of the top plate duct knockout using a hammer pliers etc Mount the 7 round duct joint removed in step 1 with 4 screws Then attach the supplied soft tape around the duct joint CAUTION Wear working gloves to avoid injury e Do not apply excessive
2. ARNING Electrical wiring should be done by a qualified person s in accordance with all applicable codes and standards including fire rated construction An ungualified person doing the work could result in fire electric shock or injury e This range hood uses 120V AC Do not connect to another voltage since fire electric shock or damage could result Remove the nut from the conduit Power connector at the end of power wiring Wiring Conduit A WARNING Be sure to switch power OFF at service panel before wiring S Nut connecting hole of the body using the Connect the conduit through the nut previously removed Conduit M E 4 S Range Hood E E N Z E Connect wires tightly and securely using Connect the electrical wires as follows wire connectors not supplied Range Hood Black to Black TE SS e White to White LLL LI e Green to Green Y Conduit AW Wire Connector T not supplied ESS Wire unit side T side Make sure that all wires are connected properly and enclosed inside of the wiring compartment 4 FINAL ASSEMBLY AND CHECK Two 60 W light bulbs not supplied can be mounted to this range hood Prior to final assembly install light bulbs halogen or ordinary type in the base diameter 26 mm rated 120 V 60 W or below 1 Replace the fan case cover with 4 screws 2 Replace the Rectifier Baffle Panel with 2 screws 3 I
3. E and the local code authorities When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities Ducted fan must always be vented to outdoors TO REDUCE THE RISK OF FIRE USE ONLY METAL DUCTWORK This unit must be grounded Install this range hood to the cabinet Check that the hood is correctly installed since incorrect installation could result in the range hood becoming detached and falling off Connect only to an AC120 Volt power source or the range hood could result in fire electric shock and damage N CAUTION For general ventilating use only Do not use to exhaust hazardous or explosive material and vapors To reduce the risk of fire and to properly exhaust air be sure to duct air outside Do not vent exhaust air into spaces within walls ceilings or into attics crawl spaces or garages Read specification label on this product for further information and requirements Use only for the purpose of kitchen ventilation Do not install this range hood in the bathroom or in other wet rooms since electrical shock and damage may result Fasten the filter and other parts securely Incorrect attachment may resulty in personal injury or property damage Keep your hands and other objects away from the fan while it is in motion The range hood may injure you or damage itself NOTE The safety instructions are explained with the following pictographic symbols means proh
4. FUJIOH Range Hood INSTALLATION MANUAL MODEL FSR 3000 FSR 3600 FSR 4200 TABLE OF CONTENTS Safety INSTUCTIONS E 3 Name O Pan an ET 5 Sie DIM NA mane naa aa 5 Range Hood Location wo oo oo oooo o o iWo o ooiis meneteskan 6 Iiic rue AA A ANS AE S 7 UM A E E AA E O 7 2 Range Hood Mounting oo W Wo Wo Wo maa 11 3 Connecting Power Supply Wires oW W WW maa 12 4 Final Assembly and Check o ooo W Woo WWW mma 13 Explanation to the End User WoWo Wo Woo Woo maa 14 ON CUM Diagrami RETRO 14 READ AND SAVE THESE INSTRUCTIONS Keep this manual in a convenient place for future reference FUJI INDUSTRIAL CO LTD 10030381 SAFETY INSTRUCTIONS Before installation and operation read these instructions carefully and use this product only in the manner described by the manufacturer in the operation manual The instructions shown below are used to alert you to potential personal injury and property damage hazards There are three hazard classifications based on potentially dangerous situations Obey all safety instructions that show these symbols to avoid possible injury death and property damage AN WARNING WARNING indicates a potentially hazardous situation which if not avoided could result in death or serious injury A CAUTION CAUTION indicates a potentially hazardous situation which if not avoided may res
5. ard According to the conditions where the hood is installed determine whether it will discharge vertically 81 x 10 or 7 Round or horizontally 3 4 x 10 only For vertical or horizontal x discharge run duct work between the H hood location and a roof cap or wall cap For the best results in either directions use a minimum number of transitions Eun and elbows Be sure to attach a roof cap or wall cap to avoid leaking rain in the ji end 31 4 x 10 DUCT For horizontal discharge Use diagrams below for proper placement of ductwork and electrical cutout in cabinet or wall E 31 x 10 Vertical Ducting 13 1 2 30 hood Naa 1 3 1 2 30 hood 16 1 2 36 hood a 16 1 2 36 hood 19 1 2 42 hood A 19 1 2 42 hood CABINET FRONT HOOD MOUNTING SCREWS 4 WOOD SHIMS recessed bottom CABINET BOTTOM cabinets only i 6 1 4 zi 5 1 4 5 1 4 a Sa E gt Z v eo ACCESSHOLE UNE ELECTRICAL A aX ACCESS HOLE 4 CENTER LINE ll 3 x 10 Horizontal Ducting WOOD SHIMS recessed bottom cabinets only HOOD MOUNTING SCREWS 4 CABINET FRONT CABINET BOTTOM ESRA HORIZONTAL DUCT ACCESS HOLE 30 hood 16 1 2 36 hood 19 1 2 42 hood 1 4 4 ola 13 1 2 30 hood E 16 1 2 36 hood un 19 1 2 42 hood A CENTER LINE E 7 Round
6. force when removing the knockout The fan may be damaged Hit dented points on the circular edge Soft Tape 7 Round Duct Joint Insert into the holes E In Case of 3 1 4 x10 Horizontal Discharge First remove half cut rectangular part of the rear plate duct knockout using a hammer pliers etc Mount the supplied 3 1 4 x10 rectangular duct joint with 2 screws Then attach the supplied soft tape around the duct joint To close the opening of the top plate attach the supplied cover plate with 2 Screws Hit dented points on the rectangular edge 4 Engage with the notches RANGE HOOD MOUNTING Referring to SIZE amp DIMENSIONS insert 4 washer head wood screws into the bottom plate of the cabinet Marking before screwing is recommended Allow about 14 between the bottom plate and screwheads for hanging the hood body With inserting the duct joint into the duct end hook the temporary fixing holes of the body on the screws then slide the body backward until the screws are engaged in narrow end of the holes e Org tor 4 After ensuring that the range hood is positioned properly tighten the 4 screws and fix it firmly using 2 more washer head wood screws Fixing Screws Make the duct joint secure and air tight Duct Tape etc using non flammable tape such as duct tape etc not supplied 11 3 CONNECTING POWER SUPPLY WIRES AN W
7. ibition It indicates actions if any that mustn t be done Q means forcible execution It indicates actions if any that must be done NAME OF PARIS Switch Rectifier Baffle Panel Duct Joint rectangular Accessories hres Ea Washer Head Screw Soft Tape Cover Plate Wood Screw x 6 pcs x 4 pcs x 1 pc x 1 pc SIZE amp DIMENSIONS Dimensions in inches a Model A B 3 39 Unit inch RANGE HOOD LOCATION The range hood must be installed just above the cooktop The minimum distance from the cooking surface to the bottom of the range hood must be 24 The total weight of the FSR series range hoods are FSR 3000 16 kg FSR 3600 17 kg FSR 4200 18 kg Power requirements are AC120 V 60 Hz 1 9 Amp 24 min aS AN CAUTION Check that the hood is correctly installed since incorrect installation could result in the detachment of the range hood and the unit fall off To protect hands from injury wear working gloves when installing the range hood INSTALLATION 1 PREPARATION A WARNING If the range hood is not installed properly it could become detached and fall off Ensure that the metal duct does not touch other metal housing materials otherwise fire or electric shock could result 31 4 x 10 or 7 ROUND DUCT For vertical discharge This range hood can discharge upward ROOF CAP or backw
8. nstall the oil catch tray Assembly refer to PREPARATION Check 1 Turn on the electrical circuit to the range hood 2 Make sure that the switch and light operate correctly Refer to page 5 of the Operation Manual 3 Check the ventilating functions at High G Medium Q and Low C3 positions 4 Make sure that the range hood has no abnormal noises and or vibration A CAUTION To reduce the risk of injury keep your hands and other objects away from the fan while it is in motion e Wear working gloves to avoid injury 13 14 Explanation to the End User 1 Referring to the Operation Manual explain the operation of this range hood to end users 2 The Installation Manual and Operation Manual should be given to the end user 120V 60Hz Main Coil2 Auxiliary Coil CIRCUIT DIAGRAM Indicating Lamp Control Switch AC125V 3A Lamp receptacle E26 T Lock Lock Release Lamp Max 60W Dy ph Reset Key Connector Black White Green Capacitor m m i I l 7uF 250VACN Main Coil 3 Thermal Cutoffs Main Coil 1 L ra rt ui I a Connector Model No 1U201361 Capacitor Running Induction Motor Single phase 120V 60Hz 100W Ins Class A 4 Poles FUJIOH Fuji Industrial Co Ltd 2 1 9 Fuchinobe Sagamihara shi Kanagawa ken 229 0006 Japan Tel 481 42 753 1001 Fax 481 42 753 1009 1U030381
9. ult in minor or moderate injury CAUTION CAUTION used without the safety alert symbol indicates a potentially hazardous situation which if not avoided may result in property damage N WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING Use this unit only in the manner intended by the manufacturer If you have questions contact the manufacturer Before servicing or cleaning the unit switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel To reduce the risk of fire or electric shock do not use this product with any solid state speed control device TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING Installation work and electrical wiring must be done by a qualified person s in accordance with all applicable codes and standards including fire rated construction oufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent back drafting Follow the heating equipment manufacturer s guidelines and safety standards such as those published by the National Fire Protection Assoiation NFPA and The American Society for Heating Refrigeration and Air Conditioning Engineers ASHRA

Download Pdf Manuals

image

Related Search

Related Contents

Manuel d`utilisation  Fujitsu AMILO Pi 3525    PASCO Specialty & Mfg. CI-6545 User's Manual  GTAI - Projekte & Ausschreibungen  VOIR le logiciel W630 en détails : ICI  平成26年10月25日発行  User Manual  Las Vegas DVD35  

Copyright © All rights reserved.
Failed to retrieve file