Home
GE 30 in. Profile JVB93SASS Electric Cooktop
Contents
1. Use and Care amp Installation Guide Downdraft Vent System A Safety Instructions Problem Solver 00001111100000 4 More questions call IN GE Answer Center 800 626 2000 Operating Instructions Tips CANNING ee E 3 N i Eoo AE EA eee ee 3 Me Installation 5 11 COOKING TIPS ceeccceecceseeceseeeeeeeseeeeseeeeneeneees 3 Ductwork Table 8 TTS Plan DUC OW OK vessininvctnisnasiaarttorssicuncsesviniiinnedai 8 T Plar VWI eiren aa 9 Install Ductwork cece eeeeeeeeeeeeeeees 10 z Care and Cleaning Install WIring nannan 10 BIOWGT erisirasnsa ten sstenetetaiiiet enaa NERE AERA 4 E Grease Filter a saasaosneonnoenneernnenesrnnerrnerrnnrrrenn 4 Consumer Services Warranty ccccccceececcsseceeseeeseeeeens Back Cover Models JVB54 JVB65 JVB35 JVB93 JVB64 JVB96 GE Appliances IMPORTANT SAFETY INSTRUCTIONS Read and save these instructions WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING A Use this unit only in the manner intended by the manufacturer If you have questions contact the manufacturer B Before servicing or cleaning unit switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel Su
2. 16 29 1 8 19 15 16 2 5 16 27 1 16 JGP330 JGP331 30 21 2 23 3 1 4 22 28 1 2 19 1 2 2 5 8 27 1 16 JGP334 Required to maintain UL or AGA approvals 6 36 COOKTOPS DOWNDRAFT UNITS JVB64 JV B65 JVB96 Figure 1 Overall Cooktop Dimensions Figure 3 Cutout for Vent J 29 1 2 K 32 1 4 es LL E E A AE J No Gas or Electric Inside Cabinet Service Clearance Inside Shaded Area Figure 2 Overall Cutout Dimensions NOTE AGAINST THE WALL INSTALLATIONS ARE LIMITED DUE TO DIMENSION REQUIREMENTS REFER TO DETAILS BELOW PLANNING INSTALLATION Note 26 deep cabinets required B amp C D I E F G H Figure 1 Figure 3 Figure 2 Figure 2 Figure 2 Figure 3 Figure 3 Min Setback Downdraft Depth Front Edge Min Req d Cooktop Cooktop Add Depth Cutout Width Cktop Cntrtop to Front Inside Cabinet Cutout Cutout Req d for Req d from Edge of Cutout Clearance Width Depth Downdraft Centerline J P 6 2 2 77 A 77 7 Pere asa 3 1 4 33 718 19 116 2 7 8 33 116 JP681 35 1 2 3 1 4 21 9 16 33 7 8 19 1 16 2 7 8 33 1 16 pe 35 1 2 20 3 4 22 3 4 22 7 16 34 5 8 19 15 16 2 5 16 33 1 16 J G P 6 3 0 r 2r PR r 2r 2r r r 2r 7r Required to maintain UL or AGA approvals Cooktop Cooktop Overall Overall Model N
3. of offset Maximum 3 recommended The effect upon airflow is dependent upon the amount of offset 2 Calculate the equivalent ducting allowances using in offset x 14 Ft per inch ___ Ft equivalent length 3 Ensure that the total equivalent length of ducting does not exceed the maximum recommendation of 100 feet Venting Island to Outside Wall Wall p 3 x 10 to 6 Round Transition 6 Round to 314 x 10 Transition 90 Elbow oft x 10 to 6 Round Transition 90 Elbow 6 Round Wall Cap with Damper of x 10 Wall Cap with Damper 6 Round Roof Cap 6 Round Roof Vent Plan the Wiring 1 The downdraft blower system draws 4 AMPS and requires a 120 VAC 60 Hz circuit 2 The unit has a 2 ft long power cord with a 3 pronged plug Plan to provide a grounded outlet in a location which will allow the unit s power cord to reach The outlet cannot be located on a back wall The outlet needs to be mounted on the side wall of the cabinet or it could be on the back wall of an adjacent cabinet with access through an opening in the side wall Based on local codes Preparation Changing Blower Discharge Optional The blower is shipped with its discharge facing DOWN Follow these steps ONLY if e The position of the blower discharge needs to be moved so the ductwork does not interfere with the floor joists plumbing or wiring be
4. STEM my Controls Turn the downdraft blower ON by pressing down on the activating switch The t air vent will rise O The blower can be ON or OFF and its speed can be oO adjusted with the recessed knob on the right side of the air vent Knob a CAUTION Be careful when raising or lowering the downdraft Be sure pots pot handles and other objects are clear of the downdraft cover and cannot be struck or tipped by the downdraft being raised e To avoid injury make sure there are no fingers around the downdraft cover when it is lowered e Keep hands and fingers away from all downdraft parts N Disconnect power to the cooktop and remove it first Reverse the steps in the Install the Downdraft section to remove the downdraft from the cabinet Service parts are available from your local GE distributor or from a GE Service and Parts Center SUOTJIN AYSUT AJIJVS Turn the downdraft blower OFF by pressing the activating switch PN again The air vent will go down and the blower 5 will shut off mm o C gt pi NOTE For most convenient operation set the blower T to your favorite speed The blower will come on to this speed whenever the activating switch is pressed and the air vent rises COOKING TIPS e The high capacity performance of this downdraft system can increase the cooking times for some foods It may take longer to reach high cooking temperatures if the downdraft is turned
5. VB96 99 04 2007B 3 98 CG Printed in the United States
6. ealer Blower 1 DISCONNECT THE DOWNDRAFT POWER SUPPLY BY REMOVING THE POWER CORD FROM THE RECEPTACLE 2 Remove the blower cover 3 Use a vacuum hose to clean the blower Do not immerse the blower in water 4 Replace the blower cover 5 Reconnect the power supply NOTE The filters are different sizes Be sure to replace them with the longer filter on the left When replacing the filters the long one goes in the left side Painted or Metal Surfaces Clean greasy surfaces frequently using a mild detergent Do not use abrasive cloth steel wool pads or scouring powder because they will mar the surface Stainless Steel on some models Clean with warm sudsy water a stainless steel cleaner such as Kleen King or an all purpose liquid or spray cleaner Always scrub in the direction of the grain Rinse thoroughly with a sponge or cloth and clean water Dry with a soft clean cloth Do not use a soap filled steel wool pad it will scratch the surface QUESTIONS USE THIS PROBLEM SOLVER POSSIBLE CAUSE PROBLEM FAN DOES NOT WORK e The vent must be fully extended before the downdraft will work e The blower control knob must be turned in a clockwise direction to turn the blower on If you need more help call toll free GE Answer Center 800 626 2000 consumer information service INSTALLATION INSTRUCTIONS Before Starting Installation Check the Following Requirements This downdraft blo
7. fficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent backdrafting Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAB and the local code authorities This unit must be grounded WARNING TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE A Keep fan filters and grease laden surfaces clean B Always turn hood ON when cooking at high heat C Use high range settings on range only when necessary Heat oil slowly on low to medium setting D Don t leave range unattended when cooking E Always use cookware and utensils appropriate for the type and amount of food being prepared WARNING TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE OBSERVE THE FOLLOWING A SMOTHER FLAMES with a close fitting lid cookie sheet or metal tray then turn off the burner BE CAREFUL TO PREVENT BURNS If the flames do not go out immediately EVACUATE AND CALL THE FIRE DEPARTMENT B NEVER PICK UP A FLAMING PAN You may be burned C DO NOT USE WATER including wet dishcloths or towels a violent steam explosion will result D Use an extinguisher ONLY if 1 You know you have Class ABC extinguisher and you already know how to o
8. he cabinet depth must be 26 minimum Minimum 26 Cabinet depth required A countertop with a raised lip may not allow enough flat countertop for a proper installation Before starting installation review the following pages carefully Cutout dimension and illustrations are given for 30 and 36 cooktops continued next page 30 COOKTOPS DOWNDRAFT UNITS JVB34 JVB35 JVB93 Figure 1 Overall Cooktop Dimensions Figure 3 Cutout for Vent J 29 1 2 K 26 1 4 e 2222222 P No Gas or Electric Service Inside Shaded Area Minimum Inside Cabinet Clearance Figure 2 Overall Cutout Dimensions NOTE AGAINST THE WALL INSTALLATIONS ARE LIMITED DUE TO DIMENSION REQUIREMENTS REFER TO DETAILS BELOW PLANNING INSTALLATION Note 26 deep cabinets required PREPARING CUTOUT B amp C D I E F G H Figure 1 Figure 3 Figure 2 Figure 2 Figure 2 Figure 3 Figure 3 Min Setback Downdraft Cooktop Cooktop Depth Front Edge Min Req d Cooktop Cooktop Add Depth Cutout Width Overall Overall Cktop Cntrtop to Front Inside Cabinet Cutout Cutout Req d for Req d from Model No Width D D Vent Edge of Cutout Clearance Width Depth Downdraft Centerline 28 1 2 19 12 2 7 8 27 1 16 J P 3 3 2 2r 2r 2r lid 2r 2r 2r 2r PP JP343 JP345 29 3 8 20 1 2 22 1 2 22 1 16 28 9 16 19 9 16 2 3 8 27 1 16 JP347 J P 3 9 2 1A I Pe nid rr rr Pr Pe Pa 30 20 3 4 22 3 4 22 7
9. inary home use in the 48 mainland states Hawaii and Washington D C In Alaska the warranty is the same except that it is LIMITED because you must pay to ship the product to the service shop or for the service technician s travel costs to your home All warranty service will be provided by our Factory Service Centers or by our authorized Customer Care servicers during normal working hours Should your appliance need service during warranty period or beyond call 800 GE CARES 800 432 2737 e Replacement of the replaceable filters e Replacement of house fuses or resetting of circuit breakers e Failure of the product if it is used for other than its intended purpose or used commercially e Damage to product caused by accident fire floods or acts of God WARRANTOR IS NOT RESPONSIBLE FOR CONSEQUENTIAL DAMAGES Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state To know what your legal rights are in your state consult your local or state consumer affairs office or your state s Attorney General Warrantor General Electric Company If further help is needed concerning this warranty write Manager Consumer Affairs GE Appliances Louisville KY 40225 JVB34 JVB64 JVB35 JVB65 Pub No 49 8904 JVB93 J
10. ling brackets can be removed and re attached in other positions The bottom flange may have to face inward in tight cabinet installations 2 Secure the downdraft to the countertop as follows Hold the downdraft against the back of the countertop cut out and tighten the 2 mounting screws one on each end of unit on the underside of the countertop Use a wood shim between the screw and the underside of granite countertops 3 Screw the leveling brackets to the bottom of the cabinet Tighten the screws holding the leveling bracket to the unit on each side 10 continued Install the Ductwork CAUTION BEFORE CUTTING A HOLE IN CABINET FOR DUCTWORK Check for interference with floor joists wall studs electrical wiring or plumbing 314 x 10 to 6 RD Transition t Blower Collar p Screws A 6 RD fo Elbow amp ductwork 1 Cut the hole in the cabinet as well as holes in the wall or floor as necessary 2 Mount the roof or wall cap and work back towards the cabinet attaching all ductwork elbows and transitions as previously planned Tape all ductwork connections to make them secure and air tight 3 Connect the ductwork and transition if required to the downdraft If necessary LOOSEN wing nuts and screws that hold the blower in place and slide the blower left or right to meet the ductwork Re tighten the screws and wing nuts NOTE A 3 x 10 collar is provided for installers who p
11. low e It is necessary to rotate the blower discharge to the RIGHT or LEFT Place the unit on its back on a table or work surface DOWN DISCHARGE Moving Blower Left or Right Sheet metal screw Blower Bottom Clamp channel flange 1 Loosen the 4 nuts and 2 clamp channels 2 Slide the blower to the desired position 3 Use the supplied cover plate to close the open space if any 4 Tighten the nuts to secure the top of the blower and use the sheet metal screws through the bottom flange to secure the bottom of the blower LEFT OR RIGHT DISCHARGE Nut Motor plug Clamp channel Cover plate 1 Remove the 4 nuts and 2 clamp channels 2 Loosen the screws holding the gear motor cover and slide it away from the blower 3 Carefully lift the blower and disconnect the motor plug if necessary Reposition the blower and reconnect the motor plug 4 Use the supplied cover plate to close any open space 5 Replace the clamp channels and use the nuts to secure the blower in its new position 6 Reposition the gear motor covers and tighten the screws 7 Use sheet metal screws through the bottom flange to secure the bottom of the blower continued next page INSTALLATION INSTRUCTIONS Leveling bracket flange facing out Leveling bracket flange facing in 1 Set the downdraft into the opening Extend the leveling brackets to the floor of the cabinet so the downdraft sits straight NOTE Leve
12. n the switch bracket so that the activating switch just comes in contact with the underside of the switch membrane Tighten the screws 5 Replace the switch cover gently lower the air vent into the chimney and plug in the power cord Re connect the electrical power and check operation I YOUR DOWNDRAFT SYSTEM WARRANTY WHAT IS COVERED WHAT IS NOT COVERED FULL ONE YEAR WARRANTY For one year from date of original purchase we will provide free of charge parts and service labor in your home to repair or replace any part of the downdraft system that fails because of a manufacturing defect e Service trips to your home to teach you how to use the product Read your Use and Care material If you then have any questions about operating the product please contact your dealer or our Consumer Affairs office at the address below or call toll free GE Answer Center 800 626 2000 l l consumer information service e Improper installation If you have an installation problem contact your dealer or installer You are responsible for providing adequate electrical exhausting and other connecting facilities as described in the Installation Instructions provided with the product Staple sales slip or cancelled check here Proof of original purchase date is needed to obtain service under warranty This warranty is extended to the original purchaser and any succeeding owner for products purchased for ord
13. o Width INSTALLATION INSTRUCTIONS continued Ul ly Left discharge aaa loo i EE ron discharge as shipped 1 This downdraft blower system is designed for use with 3 x 10 ductwork can be transitioned to 6 round Three different discharge directions are available with side to side adjustment for accurate alignment of ductwork 2 For best performance Choose the ducting option which allows the shortest length of ductwork and a minimum number of elbows and transitions Check location of floor joists wall joists wall studs electrical wiring or plumbing for possible interference NOTE The unit is shipped with the 3 x 10 discharge facing DOWN See the Changing Blower Direction section if necessary Duct Pieces 6 Round Straight 1 ft per foot length 3 x 10 1 ft per foot length Straight 6 90 Elbow 6 45 Elbow 3 4 x 10 90 Elbow 3 x 10 45 Elbow 3 4 x 10 90 Flat Elbow 6 Round to 3 x 10 Transition 24 Power Cord provided on right hand side Duct Pieces Equivalent Length SHOULD NOT EXCEED 100 EQUIVALENT FT Equivalent lengths of duct pieces are based on actual tests conducted by GE Evaluation Engineering and reflect requirements for good venting performance with a downdraft rated at 500 CFM Steps to Determine Flexible Ducting s Equivalent Length 1 Measure the actual amount
14. on to high right away Adjust the fan speed for best cooking results For best results when heating oil for deep frying or when boiling water use the front surface units or wait until the water is boiling or the oil is at frying temperatures before turning on the downdraft e The downdraft may not completely capture all the steam from pans on the front burners Canning When canning foods in a water bath canner a gentle but steady boil must be maintained continuously for the required time When canning foods in a pressure canner the pressure must be maintained continuously for the required time Use of the blower at a high speed when canning may reduce the temperature enough to stop boiling While canning we recommend using the downdraft at LOW speed and using the front surface unit sdr j suryooo 3 CARE AND CLEANING Grease Filter The efficiency of your downdraft depends on a clean filter Frequency of cleaning depends on the type of cooking you do Grease filters should be cleaned at least once a month Never operate the downdraft without the filters in place To remove Pull the filters out by grasping them and pulling straight up To clean Soak and then agitate in a hot detergent solution Light brushing may be used to remove imbedded soil Rinse shake and remove moisture before replacing With careful handling the filter will last for years If replacement becomes necessary order the part from your d
15. perate it 2 The fire is small and contained in the area where it started 3 The fire department is being called 4 You can fight the fire with your back to an exit Based on Kitchen Fire Safety Tips published by NFPA CAUTION For general ventilating use only Do not use to exhaust hazardous or explosive materials and vapors e Make sure all fingers are away from the downdraft top when it is lowered Installation Instructions for General Electric Hood WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING A Installation work and electrical wiring must be done by qualified persons s in accordance with all applicable codes and standards including fire rated construction B Ducted fans must always be vented to the outdoors WARNING To reduce the risk of fire use only metal ductwork Important Save for the local electrical inspector s use If You Need Service Do not attempt to repair or replace any part of the downdraft system unless it is specifically recommended in this guide All other servicing should be referred to a qualified technician READ AND SAVE THESE INSTRUCTIONS SERVICING A NOTE BE SURE ELECTRICAL POWER IS OFF BEFORE SERVICING THE UNIT It may be necessary to remove the downdraft blower system from the cabinet in order to service components such as the blower motor or air vent mechanism USING YOUR DOWNDRAFT VENT SY
16. refer to rivet the cutwork to the unit This will allow the blower to be removed and replaced easily in service situations without disturbing the ductwork Install the Electrical Wiring 1 Mount a standard wiring box with 3 pronged outlet inside the cabinet Make sure the downdraft s power cord can easily reach it 2 Run the appropriate power cable into the cabinet and connect it to the outlet 3 Plug the downdraft s power cord into the outlet Install the Cooktop 1 Align the cooktop with the downdraft and fasten cooktop in place NOTE Accurate alignment of cooktop and downdraft is necessary to ensure that there is not interference when air vent is raised and lowered There should be a gap of 1 32 1 16 between the back of the cooktop and the front of the downdraft cover Adjust the Switch The downdraft is factory adjusted for proper operation However shipping and handling may affect the positions of the activating switch To adjust position of activating switch WARNING To avoid possible electrical shock personal injury or death disconnect electrical power 1 If the downdraft is plugged into the electrical outlet unplug it 2 Lift the air vent straight up and cock it slightly so it remains in the UP position Screws Switch bracket Switch cover 3 Remove the switch cover from the right end of the air vent 4 Loosen the 2 screws holding the switch bracket in place Positio
17. wer system is designed to be used to exhaust smoke and odors when cooking with all GE electric and sealed burner gas cooktops not approved for standard burner gas cooktops It can be mounted in either an island or peninsula location Requirements for an approved installation e 26 minimum cabinet depth e 26 minimum from the back of the downdraft to the front of the countertop with e 23 minimum FLAT countertop surface e Plan the placement of the electrical outlet box carefully It should NOT be installed on the back wall of the cabinet because it may interfere with the downdraft It should be installed on a side wall or adjacent cabinet Make sure it is within reach of the unit s 2 ft long power cord and conforms to all local codes Install a standard wiring box with a 3 pronged outlet e Plan the location of the gas supply pipe for gas cooktops carefully to avoid interference with the downdraft installation This unit can be easily installed following these basic steps e Cut out the countertop opening e Install the downdraft in the cabinet e Connect the ductwork and electrical e Install the cooktop Take Measurements Refer to the cooktop installation instructions for dimensions of cooktop countertop cut out and cabinet requirements e The 30 models will fit in most 30 wide cabinets and the 36 models will fit in most 36 wide cabinets e To install a cooktop with this downdraft t
Download Pdf Manuals
Related Search
Related Contents
Samsung SH-S183A Manuel de l'utilisateur Zanussi ZSF 2440 Instruction Manual LEDH84179W-LD Avaya BCM 2.0 Networking User's Manual Model train control system SEXPE. Gestión de Expertos Manual de Usuario. Downloads Omnia UL_R-UL_RI - schede Service Manual Therm Pro BIWO_RevA3 User`s Manual Copyright © All rights reserved.