1. Clearances may vary due to type of cooking product and local codes Check with local inspectors to be sure standard is applicable Soffit Installation SOFFIT In this installation the ductwork running from the top of the hood will be concealed in the soffit or upper cabinetry Wall Mount Installation For this installation a decorative duct cover is avail able to conceal the ductwork running from the top of the hood Use of the duct cover requires special consideration to the installation height above the countertop OPTIONAL DUCT COVER ACCESSORIES Decorative duct covers are available in 6 and 12 heights Duct covers may be stacked in various combinations to conceal the ductwork running from the top of the hood to the ceiling e Before you begin you should determine the installa tion height of the hood and order the correct size duct cover The duct covers should be ordered at the same time as the vent hood and be on site before installation Order the duct cover corresponding to your model Fe Duct Cover e Duct Cover 6 Duct Covers Hood Model 6 Duct Cover Dimensions ZVA8T ZV48S ZX48DC6 6 H x 19 11 16 W x 11 7 8 D ZV36T ZV36S ZX36DC6 6 H x 15 3 4 W x 11 7 8 D ZV30T ZV30S ZX36DC6 6 H x 15 3 4 W x 11 7 8 D 12 Duct Covers Hood Model 12 Duct Cover Dimensions ZVA8T ZV48S ZX48DC12 12 H x 19 11 16 W x
2. 35 15 16 10 9 16 22 14 9 16 29 15 16 Top View Front of Hood 2 9 16 Back of Hood e Drill 1 8 pilot holes into the studs at the locations shown in the top view illustration IMPORTANT Soffit framing must be capable of supporting up to 150 Ibs Install Transition Onto Top of Hood Transition IMPORTANT Remove shipping tape from damper and check that damper moves freely e Place the transition piece over the hood exhaust and secure with 4 screws provided e Use duct tape to seal the connection Check to be sure the damper moves freely Mount Hood onto Soffit or Cabinet Note If mounting to the underside of a cabinet with a recessed bottom install shims to fill the gap 2eSeee5e 5 Cabinet i i f or Soffit Add Shims i If Bottom Is Recessed Engage Top A Keyhole Slots 1 4 Gap Push Back Back to Wall Wall e Drive mounting screws into the studs until they protrude 1 4 The 1 4 gap will provide clearance to engage the keyhole slots in the top of the hood e Lift hood to installation position Locate house wiring and route through the knockout from the back or top of the hood e Lift hood onto mounting screws Slide back against the rear wall e Tighten mounting screws IMPORTANT For additional support and to mini mize vibration during operation the hood must be secured to the back wall Use wall anch
3. Centerline of Installation Space Test Duct Cover Fit e Place duct cover s over the top of the hood to check for gaps Adjust the hood up or down if necessary Install Bottom Mounting Screws e Drill 1 8 pilot holes into the two lower mounting holes Enlarge the holes if they did not enter studs to 3 8 Insert anchors for wall fasteners into bottom holes Remove anchor screws and add flat washers provided Drive screws into anchors and tighten e Install 4 additional screws through the back of the hood and into the wood support 11 Installation Instructions STEP 2B Alternate Mounting Method INSTALL HOOD TO SOFFIT OR BENEATH CABINETS SKIP THIS STEP IF USING WALL MOUNTING METHOD When necessary the hood may be installed so that it is supported by the soffit e The soffit should be constructed with 2 x 4 s e Determine the installation location on the wall e Continue the centerline forward on the bottom of the cabinet or soffit e The opening above the hood should allow for the 10 round duct and clearance to slide the hood back against the wall Requires 10 1 2 Min Opening For Ductwork Sain Installation rai pese A e The 2 x 4 studs must be located as shown in the chart Dim A to accept mounting screws A g Centerline to Stud Hood Width and Keyhole Slots At the Top 19 9 16 40 23 9 16 47 15 16 13 9 16 28 17 9 16
4. Stand offs e Use a flat blade screwdriver to install stand offs into the bottom of the hood e Align implement rod to stand offs with the screw hole towards the inside of the hood Secure the rod to the stand offs with the supplied Allen wrench e Follow the same procedure on the opposite side FINALIZE INSTALLATION e Install the supplied infrared bulb s e See the Owner s Manual for instructions to test operation 15 Note While performing installations described in this book safety glasses or goggles should be worn For Monogram local service in your area call 1 800 444 1845 Note Product improvement is a continuing endeavor at General Electric Therefore materials appearance and specifications are subject to change without notice Monogram We bring good things to life General Electric Company Pub No 49 80151 2 Louisville KY 40225 Dwg No 164D4290P108 N D 762 5 03 Printed in Italy
5. outlet on the top contents Screws shown actual size 4 screws to secure the wood support to the wall POZIDRIV 3 2 flat washers for wall anchors 2 3 16 hollow wall anchors with screws to secure hood to the wall at the bottom 6 Phillips head screws to 1 safety screw and lock secure hood to the wood washer to secure the support 2 secured to blower screw is marked wood support with red paint Installation Instructions STEP 1 e Use a level to draw the cooktop centerline location Draw the line to ceiling height e Measure desired distance from the bottom of the hood to the cooking surface 30 min to 36 max Note If you are installing the hood with duct covers be sure to read Using Duct Cover Accessories page 7 Exact installation height may be determined by use of one or more duct covers e Use a level to draw a straight horizontal pencil line indicating the bottom of the hood e From the line indicating the bottom of the hood measure 15 3 8 up and draw another line for the location of the wood support See illustration FOR VERTICAL Straight Up DUCTING e Use a level to draw a centerline from the bottom of the hood to ceiling or soffit e If venting out the ceiling extend the centerline forward on the ceiling or soffit e Locate the centerline of a 10 1 2 hole on the ceiling or soffit by measuring 6 from the wall House Wiring Location e The junction box is fastened
6. sanitaire ou un garage Installation Instructions CONTENTS Parts Provided Product Dimensions Step 1 Determine Ductwork and Wiring Locations Installation Clearances Step 2A Install Hood Onto Wall Optional Duct Cover Accessories Step 2B Install Hood Beneath Soffit Advance Planning Step 3 Connect Ductwork Power Supply Step 4 Connect Electrical Duct Fittings Step 5 Install Duct Covers Using Duct Cover Accessories Step 6 Install Motor Tools and Materials Required Step 7 Install Filters Remove the packaging Step 8 Install Implement Rods PRODUCT DIMENSIONS a OO eee a ee BE a 47 15 16 _ 25 47 15 16 Model ZV48S With Straight Sides Model ZV48T With Tapered Sides n W ee at a 35 15 16 il 28 lag a5 35 15 16 Model ZV36S With Straight Sides wt 29 15 16 a iS 25 29 15 16 25 29 15 16 Model ZV30S With Straight Sides Model ZV30T With Tapered Sides Advance Planning INSTALLATION CLEARANCES These vent hoods are designed to be installed onto a wall or beneath a soffit or cabinet e Install these hoods 30 Min to 36 Max above the cooking surface These hoods may be installed 24 min above a gas or electric drop in style cooktop Always observe the 30 to 36 clearance when installed over any professional style cooktop or range Note
7. to the back of the hood on the right side Electrical Area 18 13 16 for 48 Models 12 13 16 for 36 Models 9 13 16 for 30 Models e The recessed back side of the hood provides a large area for the house wiring to exit the wall and be routed to the rear knockout and junction box e The location for the house wiring depends on the installation height of the hood and the width of the hood e Remove junction box cover and knockout Install strain relief 10 DETERMINE HOOD DUCTWORK AND WIRING LOCATIONS Top of Hood Wood a Support 1 15 3 8 e House Wiring Location dJ m r Ee a Bottom of Hood l Depending on Hood width and Installation Height FOR DUCTING THROUGH REAR WALL e Measure the supplied duct transition with any straight run length of duct used plus 90 elbow height Draw horizontal line on the wall intersecting the centerline 18 1 16 for 48 Models 12 1 16 for 36 Models 9 1 16 for 30 Models Alternate Knockout Locations If the installation requires the junction box can be relocated from the back to the top of the hood Remove 3 screws align box to top knockout and secure with original screws e Remove junction box cover and knockout Install strain relief Installation Instructions STEP 2A INSTALL HOOD ONTO WALL SKIP THIS STEP IF INSTALLING BENEATH A SOFFIT OR CABINET GO TO STEP 2B e Locate at least 2 vertical studs a
8. 11 7 8 D ZV36T ZV36S ZX36DC12 12 H x 15 3 4 W x 11 7 8 D ZV30T ZV30S ZX36DC12 12 H x 15 3 4 W x 11 7 8 D Advance Planning ADVANCE PLANNING Ductwork Planning e These vent hoods are equipped for 10 round ductwork For best performance use 10 round ductwork on the 48 wide hoods 30 and 36 hoods may be transitioned to 8 round e This hood may be vented vertically through upper cabinets soffit or ceiling A duct transition piece is supplied for vertical exhaust Use locally supplied elbows to vent horizontally through the rear wall e Determine the exact location of the vent hood e Plan the route for venting exhaust to the outdoors e Use the shortest and straightest duct route possible For satisfactory performance duct run should not exceed 150 ft equivalent length for any duct configurations e Refer to Duct Fittings chart to compute the maxi mum permissible length for duct runs to the out doors e Use metal ductwork only e Install a wall cap or roof cap with damper at the exterior opening Order the wall or roof cap and any transition needed in advance Wall Framing for Adequate Support e These vent hoods are heavy Adequate structural support must be provided Hoods must be secured to vertical studs in the wall e It is strongly recommend that the vent hood with duct cover be on site before final framing and wall finishing This will also help to accurately locate the ductwork and electr
9. Installation Instructions If you have questions call 800 GE CARES or visit our website at www monogram com 30 36 and 48 Professional Vent Hoods Models ZVA48T ZV48S ZV36T ZV36S ZV30T ZV30S Monogram We bring good things to life Installation Instructions BEFORE YOU BEGIN Read these instructions completely and carefully e IMPORTAN T Save these instructions for local inspector s use e IMPORTANT observe all governing codes and ordinances Note to Installer Be sure to leave these instructions with the Consumer Note to Consumer Keep these instructions for future reference Skill Level Installation of this vent hood requires basic mechanical and electrical skills e Completion time 1 to 3 hours Proper installation is the responsibility of the installer Product failure due to improper installation is not covered under the Warranty CAUTION Due to the weight and size of these vent hoods and to reduce the risk of personal injury or damage to the product TWO PEOPLE ARE REQUIRED FOR PROPER INSTALLATION PRUDENCE A cause du poids et de la taille de ces hottes et pour reduire le risque de blessures et de dommages IL FAUT DEUX PERSONNES POUR FAIRE L INSTALLATION CORRECTEMENT WARNING To reduce the risk of fire or electrical shock do not use this range hood with any external solid state speed control device Any such alteration from original factory wiring could result i
10. N G The improper connection of the equipment grounding conductor can result in a risk of electric shock Check with a qualified electrician or service representative if you are in doubt whether the appliance is properly grounded ADVERTISSEMENT Le mauvais branchement du fil de mise a la terre peut causer un choc lectrique En cas de doute consulter un lectricien qualifi ou un technicien pour d terminer si l appareil est a la terre DUCT FITTINGS Use this chart to compute maximum permissable lengths for duct runs to outdoors Note Do not exceed maximum permissable equivalent lengths Maximum recommended duct length for these hoods 150 feet Flexible ducting If flexible metal ducting is used all the equivalent feet values in the table should be doubled The flexible metal duct should be straight and smooth and extended as much as possible Do NOT use flexible plastic ducting Note Any home ventilation system such as a ventilation hood may interrupt the proper flow of combustion air and exhaust required by fireplaces gas furnaces gas water heaters and other naturally vented systems To minimize the chance of interruption of such naturally vented systems follow the heating equipment manufacturer s guidelines and safety standards such as those published by NFPA and ASHRAE Hoods Are Equipped For 10 Round Duct Hoods are supplied with a 10 round transition A locally supplied transition is r
11. equired for other sizes Note Outlet on top of hood is 8 1 8 x 8 Actual length of straight duct plus duct fitting equivalent Equivalent length of duct pieces are based on actual tests conducted by GE Evaluation Engineering and reflect require ments for good venting performance with any ventilation hood Advance Planning Duct Piece 10 round to 8 round Total Length Equivalent Length Quantity Used 10 ft Round straight 1 ft per foot length 3 1 4 x 24 straight 1 ft per foot length 90 elbow 15 ft 45 elbow 3 1 4 x 12 or 3 1 4 x 24 90 elbow 3 1 4 x 24 45 elbow 3 1 4 x 24 90 flat elbow 10 round to 3 1 4 x 24 transition 3 1 4 x 24 to 10 round transition 10 round to 3 1 4 x 24 transition 90 elbow 3 1 4 x 24 to 10 round transition 90 elbow Round wall cap with damper 3 1 4 x 24 wall cap with damper Round roof cap Round roof vent SDT Hsr LTN eeN Total Duct Run Advance Planning USING DUCT COVER ACCESSORIES To avoid unsightly gaps plan the hood installation height for duct cover use Use the following formula to calculate the need for one or more duct covers and to ensure a trouble free installation Ceiling Height B We recommend that the vent hood and decorative duct cover if used be on site before final f
12. ical service Decorative Duct Covers Decorative duct covers 6 and 12 high are available to fit all models The duct cover conceals the ductwork running from the top of the hood to the ceiling or soffit Stack one or more duct covers over the top of the hood to reach your ceiling height POWER SUPPLY IMPORTANT Please read carefully WARNING FOR PERSONAL SAFETY THIS APPLIANCE MUST BE PROPERLY GROUNDED ATTENTION rour ves raisons DE SECURITE CET APPAREIL DOIT ETRE CORRECTEMENT MIS A LA TERRE Remove house fuse or open circuit breaker before beginning installation Do not use an extension cord or adapter plug with this appliance Follow National electrical codes or prevail ing local codes and ordinances Electrical supply These vent hoods must be supplied with 120V 60Hz and connected to an individual properly grounded branch circuit and protected by a 15 or 20 amp circuit breaker or time delay fuse e Wiring must be 2 wire with ground e If the electrical supply does not meet the above requirements call a licensed electrician before proceeding e Route house wiring as close to the installation location as possible on the back wall or ceiling e Connect the wiring to the house wiring in accor dance with local codes Grounding instructions The grounding conductor must be connected to a ground metal permanent wiring system or an equip ment grounding terminal or lead on the hood WAR N
13. n damage to the unit and or create an electrical safety hazard ADVERTISSEMENT Pour r duire le risque d incendie ou de choc lectrique il ne faut pas utiliser cette hotte avec un r gulateur de vitesse lectronique externe Toute modification de ce type du branchement d usine peute endommager Vappareil ou cr er un risque de choc lectrique TO REDUCE THE RISK OF FIRE USE ONLY METAL DUCTWORK WARNING TO REDUCE THE RISK OF FIRE ELECTRICAL SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING A Use this unit only in the manner intended by the manufacturer If you have any questions contact the manufacturer B Before servicing or cleaning unit switch power off at the service panel and lock service panel to prevent power from being switched on accidentally If the service panel cannot be locked fasten a tag or prominent warning label to the panel ADVERTISSEMENT POUR REDUIRE LE RISQUE D INCENDIE DE CHOC ELECTRIQUE OU DE BLESSURES IL FAUT OBSERVER LES REGLES SUIVANTES A Utiliser cet appareil uniquement de la mani re pr vue par le fabricant En cas de question consulter le fabricant B Avant toute intervention ou nettoyage couper Valimentation lectrique au disjoncteur et verrouiller le panneau du disjoncteur pour viter la mise sous tension accidentelle S il n est pas possible de verrouiller le panneau du disconcteur attacher un placard ou une tiquette tr s visible au panneau e For general
14. ors to fasten bottom back of hood to the wall Installation Instructions STEP 3 CONNECT DUCTWORK e Install ductwork making connections in direction of airflow as illustrated e Secure joints in ductwork with sheetmetal screws e Wrap all duct joints with duct tape for an airtight seal e Use duct tape to seal the flange connection Reach inside the hood and push the damper up to be sure it moves freely Duct Tape Over Seam and Screw Duct Tape Over Transition STEP 4 CONNECT ELECTRICAL Verify that power is turned off at the source WARN l NG If house wiring is not 2 wire with a ground wire a ground must be provided by the installer When house wiring is aluminum be sure to use U L approved anti oxidant compound and alumi num to copper connectors ATTE NTION Si le c blage de la maison n est pas du type a deux fils avec un fil de terre l installateur doit fournir un circuit de terre Quand les fils de la maison sont en aluminium il prendre soin d utiliser de la pate antioxidation approuv e par UL et des connecteurs pour Valuminium cuivre A Remove B Insert Power Junction Box Conduit Thru Cover Strain Relief and Tighten Ground C Use UL Listed Wire Nuts e Use wire nuts to connect incoming ground to green white to white and black to black e Push wires into junction box and replace cover Be sure wi
15. ping the outside edges of the exhaust opening on the top SA i Transition AL gaasi E P Wood Mounting Support Shipping Carton Electric or battery operated drill and 1 8 3 8 bits 10 round metal duct length to suit installation Phillips and flat blad lade screwdrdivers Strain relief for junction cover 120V 60Hz 15 or 20 Amp 2 wire with ground Properly grounded branch circuit e The vent hood motor is shipped secured to the skid with 4 screws Locate and remove 2 screws on each side of the motor Discard the shipping skid and screws p e From the inside of the hood loosen do not remove the 2 screws holding the wood mounting support to the back of the hood Remove and set aside the mounting support with screws for later installation DO NOT DISCARD e Remove tape and packing material from the hood and all supplied parts Installation Preparation PARTS PROVIDED Locate the parts packed with the hood is Wood Support Duct Transition with Original Screws with Damper 2 Stainless Steel Grease Filters 3 filters with 48 models Heat Lamp O 2 with 48 models 2 Grease Filter Trays Allen Wrench 2 Implement Rods and 4 Stand offs 3 supports with 48 models For Implement Rods HARDWARE 4 Phillips head screws to PACKAGE ENNS secure the transition to the Locate and check S Ara hood
16. raming and wall finishing This will help to accurately locate studs ductwork and electrical service e Read these examples carefully to determine the need for one or more 6 or 12 duct covers A Countertop to ceiling height B Gap at the top of the hood to the ceiling C Hood installation height Plus 18 hood height NOTE Dim C should be between 48 and 54 for a 30 to 36 installation height Raise or lower the hood installation height to allow use of one or more 6 and 12 duct covers INSTALLATION EXAMPLES 9 ft Ceiling 10 ft Ceiling 24 30 8 ft ceilings When the hood is installed 30 above the cooking surface and there is no soffit or upper cabinetry order one 12 duct cover accessory cover accessories 9 ft ceilings When the hood is installed 30 above the cooking surface order two 12 duct E S 10 ft ceilings When the hood is installed 36 above the cooking surface order two 12 and one 6 duct cover accessories Installation Preparation TOOLS AND MATERIALS REQUIRED NOT SUPPLIED Duct tape Wire cutter stripper E Spirit level y Step ladder Pliers Metal Snips Saber saw or Sawsall REMOVE THE PACKAGING e Remove packages from the V shaped cardboard section Remove shipping pads e Lift the hood out of the box IM PO RTANT Lift the hood by gras
17. res are not pinched STEP 5 INSTALL DUCT COVERS Note For easier handling remove cardboard insert after film is peeled off Remove protective film from duct covers If more than one duct cover is used secure each piece together with screws provided e Place the duct cover s on top of the hood e From inside the hood secure the duct cover to the top with the small Phillips head screws supplied with the covers Installation Instructions INSTALL MOTOR Outlet Attachment Spring Slot Clip e From the inside of the hood slip motor into the attachment slot on the left e Rotate motor upwards until it snaps into the spring clip on the right e Secure the motor to the hood with the machine screw and lock washer Screw is marked with red Attachment Screw IMPORTANT Connector ends are designed to mate only one way Match flat and round connectors as shown e Plug connector into the motor 14 INSTALL FILTERS Place filter drip trays into the rear of the hood La e Insert the grease filter into the opening and drop into the trays e To remove the filters grasp the handle push the filter up and lift out Installation Instructions INSTALL IMPLEMENT RODS Stand offs Into Hood ees Use Allen Wrench to Secure Rod to
18. t the wood support e Center the supplied wood support left to right and below the 15 3 8 marked line Wood Support Ee Centerline of Installation Space e Secure the wood support to 2 or more vertical studs using at least 2 of the 4 supplied long screws IMPORTANT Screws must penetrate at least 1 1 2 into vertical studs Countersink screws into support Note The mounting screws must remain in their original shipping location These screws are positioned to engage the keyhole slots in the back of the hood Original Mounting Screws as Shipped e Adjust depth of original mounting screws in the wood support until they protrude 1 4 forward This 1 4 gap will provide clearance to hang the hood IMPORTANT Framing must be capable of supporting up to 150 Ibs Install Transition Onto Top of Hood Transition IMPORTANT Remove shipping tape from damper and check that damper moves freely e Place the transition piece over the hood exhaust and secure with 4 screws provided e Use duct tape to seal the connection Check to be sure the damper moves freely Hang Hood On Wood Support e Lift the hood and hold close to the installation location Route house wiring through the knockout and into the junction box e Place the hood over the wood support Be sure the mounting screws engage the keyhole slots in the back of the hood e Check to be sure the hood is level and centered
19. ventilating use only Do not use to exhaust hazardous or explosive materials or vapors e Structural framing installation work and electrical wiring must be done by qualified person s In accordance with all applicable codes and standards including fire rated construction e Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent back drafting Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities e Local codes vary Installation electrical connections and grounding must comply with applicable codes In the absence of local codes the vent should be in stalled in accordance with National Electrical Code ANSI NFPA 70 1990 or latest edition CAUTIO N To reduce risk of fire and to properly exhaust air be sure to duct air outside Do not vent exhaust air into spaces within walls or ceilings or into attics crawl spaces or garages P R U D E N C En faut prendre soin d installer un conduit vers l ext rieur pour r duire le risque d incendie et pouvoir vacuer l air correctement Il ne faut pas vacuer l air correctement Il ne faut pas vacuer lair dans l espace entre les parois d un mur un plafond ou un grenier un espace