Broan-NuTone PM25 Kitchen Hood
Contents
1. parts which have been subject to misuse negligence accident improper maintenance or repair other than by Broan NuTone faulty installation or installation contrary to recommended installation instructions CEILINGDUGT The duration of any implied warranty is limited to the one year period as specified for the express warranty Some states do not allow limitation on how long an implied warranty lasts so the above limitation may not apply to you BROAN NUTONE S OBLIGATION TO REPAIR OR REPLACE AT BROAN VERTICAL OR NUTONE S OPTION SHALL BE THE PURCHASER S SOLE AND EXCLUSIVE TOP VENTING REMEDY UNDER THIS WARRANTY BROAN NUTONE SHALL NOT BE LIABLE FOR INCIDENTAL CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE Some CABINET states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state This warranty supersedes all prior warranties To qualify for warranty service you must a notify Broan NuTone at the address or phone number below b give the model number and part identification and c describe the nature of any defect in the product or part At the time of requesting E L E CTR C A L G R O U N D N G warranty service you must present evidence of the original purchase date In t
2. aceite Oe Eee BROAN Nulone POWER MODULE READ AND SAVE THESE INSTRUCTIONS WARNING A iN T O REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING 1 5 6 7 8 9 Use this unit only in the manner intended by the manufacturer If you have questions contact the manufacturer at the address or telephone number listed in the warranty Before servicing or cleaning unit switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel Installation work and electrical wiring must be done by a qualified person s in accordance with all applicable codes and standards including fire rated construction codes and standards Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to pre vent backdrafting Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association NFPA and the American Society of Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities When cutting or drilling into wall or ceiling do not damage electri cal wiring and other hidden utilities To reduce the risk of fire or el
3. ectric shock do not use this range hood with an additional speed control device Ducted fans must always be vented to the outdoors To reduce the risk of fire use only metal ductwork This unit must be grounded TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE 1 Never leave surface units unattended at high settings Boilovers cause smoking and greasy spillovers that may ignite Heat oils slowly on low or medium settings Always turn hood ON when cooking at high heat or when cooking flaming foods Clean ventilating fans frequently Grease should not be allowed to accumulate on fan or filter Use proper pan size Always use cookware appropriate for the size of the surface element WARNING A iN TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE OBSERVE THE FOLLOWING 1 SMOTHER FLAMES with a close fitting lid cookie sheet or metal tray then turn off the burner BE CAREFUL TO PREVENT BURNS If the flames do not go out immediately EVACUATE AND CALL THE FIRE DEPARTMENT 2 NEVER PICK UP A FLAMING PAN You may be burned 3 DO NOT USE WATER including wet dishcloths or towels violent steam explosion will result 4 Use an extinguisher ONLY if A You know you have a Class ABC extinguisher and you al ready know how to operate it B The fire is small and contained in the area where it started C The fire department is being called D You can fight the fire with you
4. he United States contact Broan NuTone LLC NuTone Inc 926 West State Street 4820 Red Bank Road Permanently ground this unit in accordance with the latest National Electrical code and applicable local codes and ordinances A Hartford WI 53027 Cincinnati Ohio 45227 It is recommended that a permanent ground connection be made 1 800 637 1453 1 800 543 8687 to the unit using a conductor of appropriate size from a grounded i continuous metallic cold water pipe a grounded lead in the service n Canada contact Broan NuTone Canada Inc 1140 Tristar Drive Mississauga Ontario L5T 1H9 1 888 882 7626 panel or a properly driven and electrically grounded ground rod Do not ground to a gas supply pipe 626846B
5. nstall and align duct The duct round damper and roof cap are Clean with a mild detergent to preserve its lasting beauty not included with your exhaust unit These items can be pur MOTOR chased from your dealer Motor requires only minimum care to continue giving top perfor 6 Make electrical connections according to the latest National Elec mance We recommend motor lubrication every twelve 12 months trical Code and applicable local ordinances with No 20 S A E motor oil REPLACEMENT PARTS LIST Part No Description R730090 Motor Fan Blade R111447 Socket Light R610027 Filter Aluminum R561143 Switch Motor White R561142 Switch Light White WARRANTY BROAN NUTONE ONE YEAR LIMITED WARRANTY Broan NuTone warrants to the original consumer purchaser of its products that such products will be free from defects in materials or workmanship for a period of one year from the date of original purchase THERE ARE NO OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO IMPLIED WARRAN NOTE TIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ROUND DAMPER IS NOT INCLUDED During this one year period Broan NuTone will at its option repair or replace without charge any product or part which is found to be defective under normal use and service THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS ROOF CAP AND TUBES This warranty does not cover a normal maintenance and service or b any products or
6. r back to an exit Based on Kitchen Fire Safety Tips published by NFPA CAUTION A 1 For general ventilating use only Do not use to exhaust hazard ous or explosive materials and vapors 2 To avoid motor bearing damage and noisy and or unbalanced impellers keep drywall spray construction dust etc off power unit 3 For best capture of cooking impurities your range hood should be mounted so that the top of the hood is 24 30 above the cook ing surface 4 Please read specification label on product for further informa tion and requirements Installer Leave this manual with the homeowner Homeowner Operating and Cleaning information on page 2 INSTALLATION CLEANING INFORMATION 1 Lift exhaust unit into position and mark location for duct and wir FILTER ing cutout Cut holes allowing at least 1 4 clearance Note Make For greatest efficiency the permanent type aluminum foil filter should sure switches are accessible be removed and cleaned periodically 2 Cut out additional openings in cabinet and roof as required To clean the filter should be soaked in hot water and detergent 3 Remove junction box cover from exhaust unit then thoroughly rinsed 4 Pull wiring through cutout in cabinet Lift unit into position feed wiring through access hole and secure unit to cabinet with four EXTERIOR SURFACE ae 4 screws provided Your Exhaust Unit is a beautifully finished addition to your kitchen 5 I